Text version

AS SHOWN

DIRK KELLAR, SAFETY DIRECTOR, JMTC

BULBOACA TRAINING AREA

MOLDOVA ARMY TRAINING AREA

CONCEPT DESIGN: 25.06.2013

25. JUNE 2013

100 m

200 m 300 m

500 m

900 m

FIRING LINE

SCHEMATIC HIGH AND LOW VOLTAGE CONNECTIONRANGE LAYOUT WITH SERVICE ROADS

SCALE 1 : 1250

NEW TRANSFORMER STATION

NEW RANGE TOWER

P1-9 P1-8 P1-7 P1-6 P1-5 P1-4 P1-3 P1-2

P3-9 P3-8 P3-7 P3-6 P3-5 P3-4 P3-3 P3-2

P4-9 P4-8 P4-7 P4-6

P5-4 P5-3 P5-2

P7-5 P7-4 P7-3 P7-2

LVPP1

LVPP2

LVPP3

LVPP4

LV

P P

LV

P P

700 m

LV

P P

LV

P P

P7-6

P6-5 P6-4 P6-3 P6-2

350 m

400 m

250 m

650 m

800 m

FIRING LINE

0 m

E X

IS

T

IN

G R

O A

D

V1

V2

V3

V4

V5

LM2

LM1

LM3

LM4

V1

V2

V3

V4

V5

HIGH VOLTAGE LINE

CONNECT TO EXISTING 10 kV

LM3

LM4

LANE 9

LANE 8

LANE 7 LANE 6

LANE 5

LANE 4

LANE 3

LANE 2

WALKWAY 2m WIDE

SERVICE ROAD

V6

V6

PRE FINAL DESIGN: 30.08.2013

LANE 1

LANE 10

P1-1

P2-3

P1-2

P1-3

P1-4

P1-5

P1-6

P1-7

P2-5

P1-8

P1-9

P2-6

P1-10

P2-1

P2-2

P2-4

P2-7

P2-8

P2-9

P2-10

P3-1

P3-2

P3-3

P3-4

P3-5

P3-6

P3-7

P3-8

P3-9

P3-10

P4-6

P4-7

P4-8

P4-9

P4-10

P5-1

P5-2

P5-3

P5-4

P7-1

P7-2

P7-3

P7-4

P7-5

P7-6

M1

M2

M3

M4

M5

M6

M7

M8

M9

P1-1

P3-1

P1-10

P3-10

P4-10

LM2 M9 M8 M7

P5-1

P6-1

P7-1

LM1M1M2M3M4M5

M6

FOLLOWING TARGET POSITIONS NEED TO BE BUILT UP TO GET LINE OF SIGHT:

ATTENTION:

ALL TARGET PITS PER LANE NEED TO BE VISIBLE FROM THEIR FIRING POSITION!

TARGET NO. 6 AT THE 900 M LINE NEED TO BUILT UP APPOX. 2 METER ABOVE EXISTING TERRAIN

ALL 30 EA PERSONELL TARGET PITS FROM 100 TO THE 300 METER LINE TO BE BUILT UP 0,4 METER

GRAVELED TURNPAD 15 M DIAMETER

IF TAGRET PIT WILL BE RAISED 2 M SERVICE ROAD MUST BE LOCATED MIN. 4 METER ABART CONCRETE ELEMENT .

ALL TARGET PITS WILL BE CONNECTED BY 1 M WIDE GRAVELED FOOTPATH TO THE SERVICE ROAD

THE CONCRETE ELEMENT OF THE PERSONELL TARGET PITS AND 4 M FROM VEHICLE TARGET PITS

UNDER NORMAL CONDITIONS, SERVICE ROAD SHOULD BE APPART MINIMUM 2 METER FROM

P6-1

P6-2

P6-3

P6-4

P6-5

TARGET NO. 5 AT THE 800 M LINE NEED TO BUILT UP APPOX. 1.5 METER ABOVE EXISTING TERRAIN

EXISTING BERM PROFILE

FINAL DESIGN: 03.12.2013

A re aP a rk in g

T o w e r

R a n g e

P2-9 P2-8 P2-7 P2-6 P2-5 P2-4 P2-3 P2-2 P2-1P2-10

LOW VOLTAGE CABLE, NYY-J 5x95 sqmm

LOW VOLTAGE CABLE, NYY-J 5x16 sqmm

LOW VOLTAGE CABLE, NYY-J 5x16 sqmm

LOW VOLTAGE CABLE, NYY-J 5x16 sqmm

LOW VOLTAGE CABLE, NYY-J 5x10 sqmm

LOW VOLTAGE CABLE, NYY-J 5x10 sqmm

LOW VOLTAGE CABLE, NYY-J 5x10 sqmm

LOW VOLTAGE CABLE, NYY-J 5x95 sqmm

LOW VOLTAGE CABLE, NYY-J 5x10 sqmm

LOW VOLTAGE CABLE, NYY-J 5x16 sqmm

LOW VOLTAGE CABLE, NYY-J 5x16 sqmm

LOW VOLTAGE CABLE, NYY-J 5x16 sqmm

LOW VOLTAGE CABLE, NYY-J 5x10 sqmm

LOW VOLTAGE CABLE, NYY-J 5x70 sqmm

LOW VOLTAGE CABLE, NYY-J 5x70 sqmm

LOW VOLTAGE CABLE, NYY-J 5x35 sqmm

HIGH VOLTAGE CABLE, BUNDLE 3 EACH N2XS(F)2Y 1x50sqmm

VEHICLE FIGHTING POSITION

FIRING POSITION

CONCRETE PERSONNEL

S ta ti o n

T ra n s fo rm e r

UPGRADE MULTI PURPOSE RANGE

0 3

336 sqm new 112 sqm

NEW BERM PROFILE

RANGE 3

New Range Layout, 900 m, with Service Roads, Electrical Schematic and Berm Sections

13. Feb 20141 DELETION OF ELECTRICAL SYSTEM 300 M RANGE HELMUT SCHWINDL

File details come from the government source that posted it. Updated .