ATTACHMENT 69 N00019-14-R-0018
PWS Enclosure 12 T-34 SIRG: 01-50-T34C-600-6-2
NAVAIR (PMA 273) 01-50-T34C-600-6-2
U.S. NAVY T-34C
TURBO MENTOR
SEVEN DAY INSPECTION
REQUIREMENTS
February 1, 2005
T-34C
Seven Day Inspection Requirements
MAINTENANCE REQUIREMENTS CARD
CARD NUMBER
i
DATE
February 1, 2005
CHANGE #
Original
CARD NUMBER: NAVAIR (PMA 273) 01-50-T34C-600-6-2
TITLE: SEVEN DAY INSPECTION CHECKLIST
ELEC PWR
N/A
WORK AREA
WUC
ITEM
TASK DESCRIPTION/REQUIREMENT
HYD PWR
INTRODUCTION
This checklist contains abbreviated inspection requirements that are necessary to determine and ensure the integrity of the aircraft for flight.
APPLICATION
Seven Day Inspection requirements shall be accomplished every seven calendar days and have an allowable deviation requirement of plus or minus three calendar days.
When an aircraft is in an Out Of Reporting Status the Seven Day Inspection Requirements may be waived during the period of time the aircraft is physically Out Of Reporting.
When the aircraft is placed back in a Reporting Status, the Seven Day Inspection Requirements must be completed prior to the aircraft being made available for flight. At the same time the baseline for the Seven Day Inspection Requirements shall also be reestablished in the tracking system used for the aircraft.
CAUTION
Ensure area around aircraft is free of foreign objects and all safety items are properly positioned, removed or installed, as applicable.
ii
DATE
February 1, 2005
CHANGE #
Original
CARD NUMBER: NAVAIR (PMA 273) 01-50-T34C-600-6-2
TITLE: SEVEN DAY INSPECTION CHECKLIST
Change Summary:
Card Number Date Revision i February 1, 2005 Original ii February 1, 2005 Original
1 February 1, 2005 Original
2 February 1, 2005 Original
3 February 1, 2005 Original
4 February 1, 2005 Original
DATE
February 1, 2005
CHANGE #
Original
CARD NUMBER: NAVAIR (PMA 273) 01-50-T34C-600-6-2
TITLE: SEVEN DAY INSPECTION CHECKLIST
ELEC PWR
1.
1.a.
1.b.
1.c.
1.d.
1.e.
1.f.
1.g.
1.h.
1.i.
1.i.1.
1.i.2.
THINK SAFETY
NB 6 Parachute, Front Cockpit:
Serial Number Record
Check Exterior Of Container For Fraying, Contamination, Dampness, Oil or Acid Stains, Other Obvious Damage
Check Exposed Spring Opening Bands For Damage, Security, Correct
Number
Check Harness For Fraying, Correct Number, Condition Of Harness Keepers
Check External Tackings, 13 Total Correct Number and Security
Check Back Pad Attachment
Check Exterior Hardware For Damage and Corrosion
Check Ripcord Handle Pockets For Obstructions and Security Of
Handles In The Pockets
Ripcord Protector and Base Plate Protector Flaps Open
Through The Cable Eye Check Ripcord
Check For Security Exposed Grommets and Cones
DATE
February 1, 2005
CHANGE #
Original
CARD NUMBER: NAVAIR (PMA 273) 01-50-T34C-600-6-2
TITLE: SEVEN DAY INSPECTION CHECKLIST
1.i.3.
1.i.4.
1.i.5.
1.i.6.
1.i.7.
2.
2.a.
2.b.
2.c.
2.d.
2.e.
2.f.
2.g.
NB 6 Parachute, Front Cockpit (Continued):
Check Ripcord Cable Loose or Bent Pins, Broken
Strands, Corrosion
Check Snap Fasteners For Security and Corrosion
Check Exposed Ripcord Arming Cable For Dents, Nicks, Cuts, Corrosion, Security
Check Exposed Power Cable For Dents, Nicks, Cuts, Corrosion, Security
Ripcord Protector and Base Plate Protector Flaps Close
NB 6 Parachute, Rear Cockpit:
Serial Number Record
Check Exterior Of Container For Fraying, Contamination, Dampness, Oil or Acid Stains, Other Obvious Damage
Check Exposed Spring Opening Bands For Damage, Security, Correct
Number
Check Harness For Fraying, Correct Number, Condition Of Harness Keepers
Check External Tackings, 13 Total Correct Number and Security
Check Back Pad Attachment
Check Exterior Hardware For Damage and Corrosion
DATE
February 1, 2005
CHANGE #
Original
CARD NUMBER: NAVAIR (PMA 273) 01-50-T34C-600-6-2
TITLE: SEVEN DAY INSPECTION CHECKLIST
2.
2.h.
2.i.
2.i.1.
2.i.2.
2.i.3.
2.i.4.
2.i.5.
2.i.6.
2.i.7.
NB 6 Parachute, Rear Cockpit (Continued):
Check Ripcord Handle Pockets For Obstructions and Security Of
Handles In The Pockets
Ripcord Protector and Base Plate Protector Flaps Open
Through The Cable Eye Check Ripcord
Check For Security Exposed Grommets and Cones
Check Ripcord Cable Loose or Bent Pins, Broken
Strands, Corrosion
Check Snap Fasteners For Security and Corrosion
Check Exposed Ripcord Arming Cable For Dents, Nicks, Cuts, Corrosion, Security
Check Exposed Power Cable For Dents, Nicks, Cuts, Corrosion, Security
Ripcord Protector and Base Plate Protector Flaps Close
No Further Entries On This Card
DATE
February 1, 2005
CHANGE #
Original
CARD NUMBER: NAVAIR (PMA 273) 01-50-T34C-600-6-2
TITLE: SEVEN DAY INSPECTION CHECKLIST
ELEC PWR
3.
3.a.
3.b.
3.c.
3.d.
3.e.
3.f.
4.
4.a.
4.b.
Lubrication Requirements:
Note 1: Utilize VV-L-800 General Purpose Lubricating Oil to lubricate the following items.
Piano Hinge Battery Access Door
Piano Hinge Avionics Bay Access Door
Piano Hinge Rudder Trim Tab
Piano Hinge Elevator Trim Tabs
Piano Hinge Aileron Trim Tabs
Piano Hinge Cowling Doors
Landing Gear Oleo Struts:
Note 2: Utilizing Mil-H-83282C Hydraulic Fluid to clean, wipe down and coat the exposed chrome areas of the landing gear oleo struts.
Nose Landing Gear Clean/Wipe Down and Coat
With a Light Film
Main Landing Gear, Both Clean/Wipe Down and Coat
With a Light Film
No Further Entries On This Card