J-1b_Chilled Water Valve Replacement Drawings.pdf

PDF 430 KB Posted

Attached to
Solicitation for multiple projects located at Air Route Traffic Control Center in Minneapolis, MN
Solicitation number
697DCK-25-R-00354
Issued by

About this file

These technical drawings are detailed mechanical plans for the Air Route Traffic Control Center (ARTCC) in Farmington, Minnesota, specifically focusing on the Basement Chiller Room, Cooling Tower, and Pump House. The documents include three primary sheets: a Basement Chiller Room Piping Plan, Basement Chiller Room Piping Sections and Details, and a Cooling Tower Yard and Pump House Plan. The drawings illustrate complex mechanical infrastructure, including piping layouts, equipment placement, valve configurations, and system integration details for chilled water and condenser water systems. Key components shown include chiller equipment, pumps, control panels, piping routes, and associated mechanical infrastructure. The technical drawings are part of a larger renovation project for mechanical systems at the facility, with specific notes indicating planned replacements of control valves, piping adjustments, and system modifications.

View the file

Other files

File Type Posted
697DCK-25-R-00354 Amendment 07.pdf PDF
PPQ for ZMP Project.pdf PDF
697DCK-25-R-00354_Amendment 06.pdf PDF
J-16_QA for ZMP Multiple Project_Final_7.31.2025.pdf PDF
Concrete Curb Photos.pdf PDF
697DCK-25-R-00354 Amendment 05.pdf PDF
Exterior Stairs and Concrete Work.pdf PDF
Tower lights.pdf PDF
Epoxy Floor in Bolier Room.pdf PDF
Exterior Doors.pdf PDF
697DCK-25-R-00354 Amendment 04.pdf PDF
J-16_QA for ZMP Multiple Project_15 July_Solo.pdf PDF
697DCK-25-R-00354_Amendment 03.pdf PDF
697DCK-25-R-00354 Amendment 02.pdf PDF
J-17_Excerpt_ZMP_RCLR_ID01922_Tower Assessment Report_2024_DNC.pdf PDF
J-16_Q and A for ZMP Multiple Project.pdf PDF
697DCK-25-R-00354_Amendment 01.pdf PDF
J-15 Price proposal spreadsheet r.xlsx XLSX spreadsheet
J-12 FAA-C-1217H Chg 2.pdf PDF
J-10_Scope of Work_Exterior Concrete Work.pdf PDF
J-8b_ZMP Panel Replace Drawings Binder1.pdf PDF
J-4a_ZMP-04202024 GAS UNIT HEATER REPLACEMENT SPECS.pdf PDF
J-13_Hazardous Energy Standard Procedure.pdf PDF
J-9e_ZMP Boiler EOSH Impacts.pdf PDF
J-5_Scope of Work_380 Steam Humidifier.pdf PDF
J-14_DOL WD MN20250053 5 2 25.pdf PDF
J-9d_ZMP Boiler Drawing zmp-msp-e-5896-a02r Bid Option.pdf PDF
J-9b_ZMP Boiler Vent Stack Replacement Specifications.pdf PDF
J-8c_ZMP Power Panel EOSH Impacts.pdf PDF
J-8a_ZMP Panel Replace Specs.pdf PDF
J-6b ZMP AHU 12 and 13 Humidifier Replacement Drawings.pdf PDF
J-2_Scope of Work_Epoxy Floor.pdf PDF
697DCK-25-R-00354_Final.pdf PDF
J-11 FAA-STD-019G.pdf PDF
J-9c_ZMP Boiler Drawing zmp-1203733-m001 Rev A.pdf PDF
J-9a_ZMP Boiler Scope of Work.pdf PDF
J-7_ZMP NASET Obstruction Lights SOW.pdf PDF
J-6c ZMP AHU 13 and 13 Humidifier Replace EOSH Impacts.pdf PDF
J-6a_ZMP AHU 12 and 13 Humidifier Replacement Spec.pdf PDF
J-4c_ZMP Gas Unit Heater EOSH Impacts.pdf PDF
J-4b_ZMP Gas Unit Heater Replacement Drawings (3).pdf PDF
J-3_Scope of Work_Exterior Doors.pdf PDF
J-1c_EOSH Impacts Chilled Water Valve Replace.pdf PDF
J-1a_Chilled Water Valve Replacement Project Spec.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

G

F

E

D

C

B

A

7 6 5

DDCP POWER SUPPLY (UPPER)-�

-DDCP PANEL PCU-0013 (UPPER)

�DDCP PANEL PCU-0014 (UPPER)

10" C TR

r

FAN STACK AND SCREEN� I

coo

2" PURGE LINE

FROM SEPARATOR� -

' I

VFD

L -,-+----->c--' ----t-/ --f-/ __ \_,,_----'<-\ ------,'-/_--+�--+-'-1

+-____ --+-----HI w, "lj__-----,..._�Y � � � H �� i��· I i I D" CTS �_!_::

' ' (f)

;u-±-□ -�------�-7 f-l :;,....:i=-,r4-

-o---r--1

1 o,, c Ts � '-ABO v E:: I I in " "- "- H- GRADE

:1 I : 'Q]JrV i--J ::: : 11;;:� :::�� i - - - - -d :I I � u' 'U p.1 t--r- :: I I ! • • I

",->--±---"''------�-� VT'

c I �---�-- 1 [± !: r4 : 0 ! 10" C TS ti:: H r----t==:Ji-----t-------t-----t-------j ! "'=" � BYJ q=-- l

PUMP

HOUSE

10" CTR

:1 I :@���� -)- � -<"�

1 2 ,. v, jg1 ~ _J ,__ L_ FLUME i i----10" C TR :J 4" � / p \ �t +-. ill'.' �

T

� J:"'_ -t------,--------, e-------------------<-=--.c-,___-----.-J,.t-��=-=--�-1 -tit�� r

\W ______ ITT4_ "" - c_c_ 3-=-:)--�.�AERGROUND

------------10" CTR-----------------1 - 1 -----1-�-+-10" C TR ---j_-1-"'-- --------f---(-------- ------10" CTR-----: i :

---=l1 =-- 'l /

ES

ABOVE GRADE_/

t�:- -►�"3---

' l E

- ��� _C_�����-----i: �

::: 1< �--;-__ -_i l __ -__ -__ �_-__ -_ � -----------il, \1!1 1 1 1 ,. 1 I ,,----..__ l!h-----�

>------------------� Iii :::SEPARA TOR�,,:, l!--11

0_ L-�,�!

Mc

I I I I I I I 3" BFP I :J -

·= I �� �'--:7 I �(�I_i N

EXIS TING rq frl

UNDERGROUND LINES I 1T1 0 /

TO WHI TE E/G'S-----+-<1

i I Ii I 3"1W MAKE UP_J l!I 1,1 SEPARA TOR-� ! i ! ! i ! CON TROL PANEL CP-1

INHIBI TOR- ACID

PUMP PUMP

CB COOLING TOWER AND PUMP HOUSE PLAN

M040 SCALE: 1/4" • 1'·0"

6 5

'--...______.,/ -BROMINA TOR

-INHIBI TOR TANK

W/ TANK S TAND

4 3

4 3

2 1

SHEET NOTES:

A SHUT OFF ISOLATION VAi. VE TO BYPASS PIPING TO Al.LOW FOR

"-:/ NEW WORK

A REPLACE CONTROL VAi.VE AND ACTUATOR FOR CONDENSER WATER

"-:/ PIPING. RECONNECT FCV TO EXISTING POWER AND TO DOC SYSTEM.

CONDENSER WATER PIPING MAY NEED TO BE AOJSUTED TO FIT NEW

CONTROL V Al. VE.

REV A PPROVED

DATE DESCRIPTION JCN REDLINE APVD DATE

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

ENGINEERING SERVICES, GREAT LAKES REGION CHICAGO, IL

ARTCC

RENOVATION OF MECHANICAL SYSTEMS

CHILLED WATER VALVE REPLACEMENT

COOLING TOWER YARD AND PUMP HOUSE PLAN

FARMINGTON AIR ROUTE TRAFFIC CONTROL CENTER

REVIEWED BY

SUBMITTED

PROJECT ENGINEER EN ROUTE ENGINEERING MANAGER

MN

DESI GNED ISSUED BY DATE JCN

1--------a---+D-RA_w_N

____ IR-'-=<S

[NGIN[ERING SERVIC[S >-DRA-w-1 N-G��0=

=02�

�---1 5=0�6-r

J==--!

1-------<

--+c=H=

Ec =KE D

--�1R=--is [N ROUTE/FSS

ZMP-GL -D-ARTCC-M040

XXX

2 I 1

X

H

G

F

E

D

C

0 "' :::) 8s a,: "'.. "' Ill 8; z "'0 "' 0 175

A C "' u

0 w

THIS DRAWING PRODUCED ON THE XXXXXXXXXX REGION MICROST ATION SYSTEM

zmp-d-artcc-m023
zmp-d-artcc-m024
ZMP-GL-D-ARTCC-M040

File details come from the government source that posted it. Updated .