This document is a unit dimension drawing for the RenewAire HE05INV energy recovery ventilation system. The drawing provides detailed mechanical specifications and installation requirements for this heat recovery ventilation unit designed for residential or light commercial applications.
The HE05INV unit measures 34 5/8 inches in width and has an overall depth of 39 7/8 inches with a case depth of 11.9±0.1 inches excluding hardware. The unit features bolt-on doors with a 12.1±0.1 inch overall depth dependent on door gasket compression, and requires a minimum 10-inch service area for maintenance access and a 34 1/2-inch minimum service area on one side. The unit includes four 8-inch duct collars (37 5/8 inches overall), a disconnect switch, four pressure ports, high-speed fan with potentiometers, and knockouts for power input and low voltage connections (available in 7/8-inch and 2-inch alternate configurations). The system accommodates four air flow paths: Outside Air (OA) intake, Supply Air (SA) to inside, Room Air (RA) to be exhausted, and Exhaust Air (EA) to outside. Hanging brackets are available in 36-inch, 37 3/8-inch, and 40 3/8-inch lengths for different installation orientations. The unit may be installed in any orientation and dimensions are rounded to the nearest eighth of an inch. This drawing version is dated JAN25 and is subject to change without notice.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
34 5/8" Case
/8 " H an gi ng B ra ck et A cc es so ry
, O rie nt at io n
B
/8 " H an gi ng B ra ck et A cc es so ry
, O rie nt at io n
A
36" Hanging Bracket Accessory
Orientation A or B
EA
RA
SA
Disconnect Switch
Pressure Ports (4) Typ.
High Speed Fan Potentiometers
7/8" Knockout Power In
2" Alternate 7/8" Knockout
Power In Back of Unit
5/ 8"
C as e
11.9±0.1 Case Excluding Hardware
5 7/8" (4)
2)
1/ 2"
(2
7/8" Knockout Low Voltage
Alternate 7/8"
Knockout Power In
8" (4) Duct Collar
5/ 8"
O ve ra ll
/8 " O ve ra ll w
Fe et
A cc es so ry (4
8 3/4"
4 1/2" 6"
12.1±0.1 Overall Actual value dependent on door gasket compression
7/ 8"
O ve ra ll
7" Alternate 7/8" Knockout
Power In
13"
10" Minimum Service Area
/2 " M in im um Se rv ic e A re a
Bolt-On Doors
TOP VIEW
LEFT VIEW FRONT VIEW RIGHT VIEW
OA
Model: HE05INV Drawing Type: Unit Dimension Version: JAN25
ABBREVIATIONS
EA: Exhaust Air to Outside OA: Outside Air Intake RA: Room Air to be Exhausted SA: Supply Air to Inside
INSTALLATION ORIENTATION
Unit may be installed in any orientation.
NOTE
1. UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE ROUNDED TO THE
NEAREST EIGHTH OF AN INCH.
2. SPECIFICATIONS MAY BE SUBJECT
TO CHANGE WITHOUT NOTICE.
| Sheet1 |
| Drawing View1 |
| Drawing View3 |
| Drawing View4 |
| Drawing View5 |
File details come from the government source that posted it. Updated .