Fort Garland - Advertisement - Appendix K - Construction Drawings.pdf
PDF 46 MB Posted
- Attached to
- Fort Garland 7+1 Bay VSF
- Solicitation number
- 23704
- Issued by
- Custer County, Colorado
About this file
This document is a Construction Drawings Appendix K for the Colorado Department of Transportation (CDOT) Region 5, specifically for a 7+1 Bay Vehicle Storage Facility (VSF) project located in Fort Garland, Costilla County, Colorado. The project involves constructing a new vehicle storage facility on undeveloped land adjacent to an existing CDOT maintenance yard, with construction documents progressing through multiple stages from 65% to 100% completion. Key document dates include progressive milestones on 04/18/2025, 05/30/2025, 07/03/2025, and 07/28/2025, culminating in a 100% bid set on 08/18/2025.
The construction drawings provide detailed technical specifications, including compliance with 2021 International Energy Conservation Code (IECC) for commercial energy efficiency in Climate Zone 6B. The facility will encompass approximately 7,258.82 square feet of parking garage space (classified as S-1 occupancy) and 773.50 square feet of business space (classified as B occupancy), with specific requirements for building envelope, insulation, fenestration, and door specifications. The project includes civil engineering plans covering wastewater, site conditions, demolition, grading, stormwater management, and utility infrastructure, ensuring comprehensive planning for the new CDOT maintenance facility.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
IM
cl ou d:
v eg aa rc hi te ct ur e
- B
IM
cl ou d S of tw ar e as a
S er vi ce
/P R
O
JE
C
TS
/C D
O T.
Ft G ar la nd /C
D O
T_ Ft
G ar la nd
_A C
PROJECT # 23704
.00
.VX
XX
X
FT
G
A R
LA
N
D
+1 B
AY
V
S F
C O
LO
R A D
O D
EP
A R
TM
EN
T
O F
TR
A N
S
PO
R
TA
TI
O
N R
EG
IO
N
H W
Y
FO
R T
G A R
LA
N D
C O
LO
R A D
O
06.27.2025 PROGRESS
DEPARTMENT OF TRANSPORTATION
DEPARTMENT OF TRANSPORTATION
65% CONSTRUCTION DOCS
85% CONSTRUCTION DOCS
99% CONSTRUCTION DOCS
RESPONSE TO COMMENTS
04/18/2025
05/30/2025
07/03/2025
07/28/2025
100% BID SET508/18/2025
DATE No. DESCRIPTION
DOOR NUMBER TAG
ELEVATION CALL-OUT
KEYNOTE TAG
WINDOW TYPE TAG
WALL TYPE TAG
DETAIL CALL-OUT
SECTION CALL-OUT
SYMBOLS
HATCH LEGEND
A A4
A4
A4
ID
W2
A4 1
STAINLESS STEEL
EARTH/COMPACTED SOIL
GRAVEL FILL
CAST IN PLACE CONCRETE,
MASONRY
GROUT FILLED MASONRY
STEEL
METAL ROOF PANEL
METAL WALL PANEL
METAL WALL PANEL, BEYOND
WOOD WORK
CONTINUOUS FRAMING MEMBER
DISCONTINUOUS FRAMING MEMBER
BATT INSULATION
RIGID INSULATION
EXISTING TO BE DEMOLISHED
EXISTING WALL TO REMAIN
A4
(VEHICLE STORAGE)
117' MAX TRAVEL PATH TO NEAREST
EXIT < 200' PER IBC TABLE 1017.2
PARKING GARAGE
S-1 7,258.82 sf / 200 gross
= 37 occupants
2 EXITS REQUIRED
BUSINESS
B 773.50 sf / 150 gross
= 6 occupants
CIVIL
WASTEWATER
COVER
C000 C001 C002 C100 C101 C110 C200 C300 C301 C302 C303 C304 C305 C400 C500 C501 C502 C503
WW-001
WW-100
WW-500
CODE INFORMATION AND INDEX
CIVIL COVER SHEET
EXISTING CONDITIONS PLAN
DEMOLITION PLAN
OVERALL SITE PLAN
SITE PLAN
HORIZONTAL CONTROL PLAN
GRADING PLAN
STORMWATER MANAGEMENT PLAN (SWMP) COVER SHEET
INITIAL SWMP PLAN
INTERIM SWMP PLAN
FINAL SWMP PLAN
SWMP DETAILS (1 OF 2)
SWMP DETAILS (2 OF 2)
UTILITY PLAN
CIVIL DETAILS
CDOT DETAILS
CDOT DETAILS
POND DETAILS
OWTS NOTES
OWTS SITE PLAN
OWTS COMPONENT DETAILS
96' MAX TRAVEL PATH
TO NEAREST EXIT
BUSINESS
B 966.72 sf / 150 gross
= 7 occupants
IECC COMPLIANCE
2021 IECC | COMMERCIAL ENERGY EFFICIENCY REQUIREMENTS FOR COSTILLA COUNTY
PRESCRIPTIVE COMPLIANCE PATH | CLIMATE ZONE 6B
BUILDING ENVELOPE REQUIREMENTS -- OPAQUE ASSEMBLIES (TABLE C402.1.3 AND C402.1.4)
REQUIRED: PROVIDED:
ROOFS (METAL BUILDINGS) R-25 + R-11LS R-25 + R-11LS
WALLS, ABOVE GRADE
(METAL BUILDINGS) R-13 + R-14 ci R-13 + R-15 ci WALLS, BELOW GRADE R-10 ci N/A
FLOORS
MASS R-16.7 ci N/A
JOIST/FRAMING R-38 N/A
SLAB-ON-GRADE R-20 FOR 24" BELOW R-20 FOR 24" BELOW
SWINGING DOORS U-0.37 U-0.37
GARAGE DOORS U-0.31 U-0.31
(OVERHEAD DOORS)
C303.1.3 WINDOWS, DOORS AND SKYLIGHTS LACKING A LABELED U-FACTOR SHALL BE ASSIGNED A DEFAULT U-FACTOR FROM TABLES C303.1.3(1) AND C303.1.2.3(2) PRODUCTS LACKING A LABELED
SHGC OR VT SHALL BE ASSIGNED A DEFAULT VALUE FROM TABLE C303.1.3(3).
BUILDING ENVELOPE REQUIREMENTS -- FENESTRATION (TABLE C402.4)
REQUIRED:
FIXED FENESTRATION U-0.34
OPERABLE FENESTRATION U-0.42
ENTRANCE DOOR U-0.63
SHGC FIXED OPERABLE
PF<0.2 0.38 0.34
0.2 ≤ PF < 0.5 0.46 0.41
PF ≥ 0.5 0.64 0.54
THERMAL ENVELOPE CERTIFICATE (C401.3)
A PERMANENT THERMAL ENVELOPE CERTIFICATE SHALL BE POSTED IN THE BUILDING UPON
SUBSTANTIAL COMPLETION AND UPON CONFIRMATION THAT AS-BUILT CONDITIONS MEET THE
ABOVE REQUIREMENTS.
GOVERNING AUTHORITY: STATE OF COLORADO
SCOPE OF WORK:
SINGLE STORY PRE-ENGINEERED METAL BUILDING (PEMB) VEHICLE STORAGE FACILITY (VSF). THE VSF WILL CONTAIN 7 BAYS FOR CDOT PLOW TRUCKS,TWO OF WHICH WILL BE SECTIONED OFF AS A WASH BAY. AN ADDITIONAL BAY WITH MEZZANINE WILL CONTAIN ADMINISTRATIVE FUNCTIONS.
SITE WORK INCLUDES THE PAVING OF NEW DRIVES, PARKING, AND SIDEWALKS. A NEW SEPTIC
TANK AND LEACH FIELD SYSTEM ARE ALSO INCLUDED.
OCCUPANCY CLASSIFICATION: NON-SEPARATED MIXED-USE: GROUPS B AND S-1
TYPE OF CONSTRUCTION: TYPE V B
BUILDING IS NOT SPRINKLERED
ALLOWABLE BUILDING HEIGHT: 40'-0" (1 STORY )
PROPOSED BUILDING HEIGHT: 27'-0" (1 STORY)
ALLOWABLE BUILDING AREA: 9,000 SF
PROPOSED BUILDING AREA: 8,250 SF GROSS BUILDING AREA
+ 970 SF MEZZANINE
TOTAL EXISTING LOT AREA: 433,123 SF
AUTOMATIC SPRINKLER, FIRE ALARM AND DETECTION SYSTEMS
GROUP B: NO FIRE SPRINKLER SYSTEM REQUIREMENTS FOR GROUP B OCCUPANCY. NOT
REQUIRED TO BE EQUIPPED WITH FIRE ALARM AND DETECTION SYSTEM PER 907.2.2
GROUP S-1: NO SPRINKLER SYSTEM REQUIREMENTS FOR GROUP S-1 OCCUPANCY FIRE AREAS
NOT EXCEEDING 12,000 SF. NO FIRE ALARM REQUIREMENTS FOR GROUP S-1
OCCUPANCIES.
Table 2902.1MINIMUM NUMBER OF PLUMBING FIXTURES
OCCUPANCY TABULATION
BUSINESS 1,741 SF / 150 GROSS = 12 OCC
PARKING GARAGE 7,259 SF / 200 GROSS = 37 OCC
TOTAL = 49 OCCUPANTS
NOTE: OCCUPANT LOAD BASED ON AGGREGATE OCCUPANCIES. REFER TO EGRESS PLAN
FOR OCCUPANCY LOADS OF INDIVIDUAL SPACES.
Table 1004.5OCCUPANT LOAD
PLUMBING FIXTURE CALCULATIONS
WATER DRINKING
CLASSIFICATION CLOSETS LAVATORIES FOUNTAINS
MALE FEMALE
BUSINESS 12 OCC 1/25 / 2 = 0.240 1/25 / 2 = 0.240 1/40 = 0.300 1/100 = 0.120
STORAGE 37 OCC 1/100 / 2 = 0.185 1/100 / 2 = 0.185 1/100 = 0.370 1/1000 = 0.037
= 0.425 = 0.425 = 0.670 = 0.157
REQUIRED = 1 = 1 = 1 = 1
PROVIDED = 1 = 1 = 2 = 2
Section 903 and 907
IFC SECTION 903.2.9.1 REQUIRES A SPRINKLER SYSTEM FOR S-1 REPAIR GARAGES WITH FIRE
AREAS GREATER THAN 12,000 SQUARE FEET AND FOR STORAGE OF COMMERCIAL VEHICLES
GREATER THAN 5,000 SF. THE FIRE AREA OF THE VEHICLE STORAGE FACILITY, S-1, DOES NOT EXCEED 12,000 SQUARE FEET AND 903.2.9.1(2) DOES NOT APPLY. PER 2018 IFC, THE DEFINITION OF
A COMMERCIAL MOTOR VEHICLE IS "A MOTOR VEHICLE USED TO TRANSPORT PASSENGERS OR
PROPERTY .. " CDOT PLOWS TRANSPORT NEITHER PASSENGERS OR PROPERTY,AND SO BY
DEFINITION IS NOT A COMMERCIAL MOTOR VEHICLE. THEREFORE, SECTION 903.2.9.1(4) DOES NOT
APPLY. THEREFORE NO FIRE SPRINKLER SYSTEM IS REQUIRED AND WILL NOT BE PROVIDED.
IN ADDITION TO ALL REQUIRED ILLUMINATED EXIT SIGNAGE, GC TO PROVIDE BRAILLE EXIT SIGN ADJACENT TO ALL DOORS MARKED AS EXITS. SIGN TO SAY 'EXIT IN RAISED LETTERS AND BRAILLE IN COMPLIANCE WITH ANSI A117.1 AND TO BE MOUNTED ON THE LEVER SIDE, ADJACENT TO THE DOOR, IN THE DIRECTION OF TRAVEL, AT A HEIGHT AT A MINIMUM OF 48" AND MAXIMUM OF 60".
WHERE EXIT DOOR IS NOT CONSIDERED ACCESSIBLE, PROVIDE A SIGN THAT INDICATES THE
DIRECTION OF THE NEAREST ACCESSIBLE EXIT.
CODE PLAN NOTES
1. PER IBC 1016.2 (2) EGRESS FROM A ROOM OR SPACE MAY PASS THROUGH ADJOINING OR
INTERVENING ROOMS OR AREAS WHERE SUCH ADJOINING ROOMS OR AREAS AND THE
AREA SERVED ARE ACCESSORY TO ONE OR THE OTHER, ARE NOT A GROUP H OCCUPANCY,
AND PROVIDE A DISCERNIBLE PATH OF EGRESS TRAVEL TO AN EXIT.
2. GC TO PROVIDE FIRE EXTINGUISHERS AT LOCATIONS AS DIRECTED BY THE LOCAL FIRE
DEPARTMENT. PER 2021 IFC TABLE 906.3(1) PROVIDE ONE FIRE EXTINGUISHER FOR EVERY
1,500 SQ FT FOR NORMAL HAZARD: 9,220 SF = SEVEN FIRE EXTINGUISHERS .
CODE SUMMARY
Section 505MEZZANINES
505.2.1 AREA LIMITATION. THE AGGREGATE AREA OF A MEZZANINE WITHIN A ROOM SHALL
BE NOT GREATER THAN ONE-THIRD OF THE FLOOR AREA OF THAT ROOM.
FIRST LEVEL = 8,250 SF
MEZZANINE = 970 SF
970 SF / 8,250 SF = 12% < 33%
505.2.3 OPENNESS, EXCEPTION 1. MEZZANINES OR PORTIONS THEREOF ARE NOT
REQUIRED TO BE OPEN TO THE ROOM IN WHICH THE MEZZANINES ARE LOCATED,
PROVIDED THAT THE OCCUPANT LOAD OF THE AGGREGATE AREA OF THE
ENCLOSED SPACE IS NOT GREATER THAN 10.
ARCHITECTURAL
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
WATER TREATMENT
A0.1 A2.0 A2.1 A2.2 A2.3 A3.0 A3.1 A4.0 A4.1 A4.2
S1.0 S2.0 S3.0 S3.1 S3.2
M0.1 M2.0 M3.0 M3.1 M3.2 M3.3 M4.0
P0.1 P2.0 P2.1 P3.0 P3.1 P4.0 P4.1
E0.0 E0.1 E0.2 E0.3 E1.0 E2.0 E3.0
WTS.1
GENERAL NOTES / SCHEDULES
FLOOR PLANS
REFLECTED CEILING PLANS
ROOF PLAN / FLOOR SLAB PLAN
ENLARGED PLANS AND RESTROOM ELEVATIONS
EXTERIOR ELEVATIONS
BUILDING SECTIONS AND INTERIOR ELEVATIONS
SECTIONS AND DETAILS
SECTIONS AND DETAILS
SECTIONS AND DETAILS
STRUCTURAL GENERAL NOTES
FOUNDATION AND SLAB PLAN
DETAILS 301-320
DETAILS 321-340
DETAILS 341-360
MECHANICAL COVER SHEET
MECHANICAL FLOOR PLANS
MECHANICAL SCHEDULES
MECHANICAL SCHEDULES
MECHANICAL SCHEDULES
MECHANICAL COMCHECK
MECHANICAL DETAILS
PLUMBING COVER SHEET
PLUMBING FLOOR PLANS
ENLARGED PLUMBING PLAN
PLUMBING SCHEDULES
PLUMBING SCHEDULES
PLUMBING DETAILS
PLUMBING DETAILS
COVER SHEET
ELECTRICAL ONE LINE DIAGRAM AND SCHEDULES
SCHEDULES
ELECTRICAL COMCHECK
POWER PLAN
LIGHTING PLAN
SITE ELECTRICAL PLAN
WATER TREATMENT SYSTEM LAYOUT
STANDARD ABBREVIATIONS
DESIGN TEAM
DRAWING INDEXUTILITY INFORMATION
VICINITY MAP
APPLICABLE CODES
SCALE: 1/16" = 1'-0"
CODE PLAN: Mezzanine
SCALE: 1/16" = 1'-0"
CODE PLAN: First Level
PROJECT LOCATION:
29152 HWY 159
FORT GARLAND, COLORADO 81133
A.B. ANCHOR BOLT
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
ADD ADDENDUM
ADD'L ADDITIONAL
ADJ ADJACENT.ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING
JURISDICTION
ALUM ALUMINUM
ALT ALTERNATE
AOR ARCHITECT OF RECORD
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AVG AVERAGE
B/C BACK OF CURB
BLDG BUILDING
B.O. BOTTOM OF
BOT, BTM BOTTOM
BRNZ BRONZE
BTWN BETWEEN
CA COMRESSED AIR
CAB CABINET
CAP CAPACITY
CFM CUBIC FEET PER MINUTE
CIP CAST-IN-PLACE
C.T. CONTROL JOINT,
CONSTRUCTION JOINT
C/L CENTERLINE
CLG CEILING
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
C.O. CLEAN OUT
COL COLUMN
CONG CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CPT CARPET
CT CERAMIC TILE
C/W CURTAIN WALL
CW COLDWATER
D/B DESIGN/BUILD CONTRACTOR
DBL DOUBLE
DEMO DEMOLISH, DEMOLITION
OF DRINKING FOUNTAIN
DIA DIAMETER
DN DOWN
DS DOWNSPOUT
DTL, DET DETAIL
DWG DRAWING
(E) INDICATES EXISTING
EA EACH
E.B. EXPANSION BOLT
E.J. EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATION
ENCL ENCLOSE(URE)
EQ EQUAL
EQUIP EQUIPMENT
ESEW EMERGENCY SHOWER & EYE WASH
EUH ELECTRIC UNIT HEATER
EWC ELECTRICAL WATER COOLER
EWH ELECTRIC WATER HEATER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION, EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FBO FURNISHED BY OTHERS
FD FLOOR DRAIN, FIRE DAMPER
FDN FOUNDATION
FE FIRE EXTINGUISHER
FIXT FIXTURE
F/L FLOW LINE
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FPM FEET PER MINUTE
FRP FIBER REINFORCED PLASTIC
FT,' FOOT, FEET
FTG FOOTING
FPWH FREEZEPROOF WALL HYDRANT
GB GGA GAUGE
GAL GALLON
GALV GALVANIZED
RAB BAR
GC GENERAL CONTRACTOR
GL GLASS
GPM GALLONS PER MINUTE
GSF GROSS SQUARE FEET
GYP BD GYPSUM BOARD
HB HOSE BIBB
HDR HEADER
HDWR HARDWARE
HID HIGH INTENSITY DISCHARGE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSEPOWER
HT HEIGHT
HTR HEATER
HVAC HEATING VENTILATING & A/C
HW HOT WATER
HWY HIGHWAY
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN," INCHES
INCL INCLUDE[D)(ING)
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JT JOINT
KVA KILOVOLT - AMPERES
KW KILOWATT
L ANGLE
LAM LAMINATE
LAV LAVATORY
LT LIGHT
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MLP METAL LINER PANEL
MP METAL PANEL
MSB MOP SINK BASIN
MTD MOUNTED
MTL METAL
NEC NATIONAL ELECTRIC CODE
NSF NET SQUARE FEET
N NORTH
NIC NOT IN CONTRACT
NO OR # NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O.C. ON CENTER(S)
OD OUTSIDE DIAMETER
OHD OVERHEAD
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
O.T.S. OPEN TO STRUCTURE
P/C PRECAST CONCRETE
PEMB PRE-ENGINEERED MTL BLDG
PFM PRE-FINISHED METAL
PL PLATE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PTD PAPER TOWEL DISPENSER
PVC POLYVINYL CHLORIDE
QTY QUANTITY
R RISER
R/A RETURN AIR
RB RUBBER BASE
RE: REFERENCE
REBAR REINFORCING BAR
RECPT RECEPTACLE
REINF REINFORCE(D)(ING)
REQ'D REQUIRED
RH RADIANT HEAT
RM ROOM
ROW RIGHT OF WAY
S SOUTH
SAN SANITARY
SC SEALED CONCRETE
SCHED SCHEDULE(D)
SD SOAP DISPENSER
SEC SECTION, SECOND
SF SQUARE FEET
SIM SIMILAR
SOG SLAB ON GRADE
SPECS SPECIFICATIONS
SQ SQUARE
SSTL STAINLESS STEEL
S/S SERVICE SINK
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE(AL)
SUSP SUSPENDED
TA TOILET ACCESSORY
TBD TO BE DETERMINED
TD TOILET PAPER DISPENSER
TEL TELEPHONE
T&G TONGUE AND GROOVE
THK THICK
T.O. TOP OF
T.O.C TOP OF CONCRETE
T.O.ST. TOP OF STEEL
T.O.S TOP OF SLAB
T.O.W TOP OFWALL
TS STEEL TUBING
T-STAT THERMOSTAT
TYP TYPICAL
UNFIN UNFINISHED
UL UNDERWRITER LABORATORY
UON UNLESS OTHERWISE NOTED
UR URINAL
V VOLT
VAR VARIES, VARIABLE
VENT VENTILATION
VIF VERIFY IN FIELD
VR VAPOR RETARDER
VRF VAPOR RETARDER FABRIC
VTR VENT THROUGH ROOF
W WEST, WIDE
W/ WITH
WC WATER CLOSET
WD WOOD
WH WATER HEATER
W/O WITHOUT
WT WEIGHT
X TIMES OR BY
GAS: PROPANE
ELECTRIC: XCEL ENERGY
WATER: FT GARLAND WATER AND SANITATION DISTRICT
711 NARCISSO AVE
FORT GARLAND, CO 81133
(719) 379-2660
SEWER: SEPTIC SYSTEM
FIRE: COSTILLA COUNTY FIRE PROTECTION DISTRICT
301 BEAUBION AVE
FT GARLAND, CO 811333
FIRE CHIEF - THELDON SMITH (719) 588-3429
ARCHITECT OF RECORD:
DAVID GROOMS
vega architecture llc 495 w cedar ave denver, co 80223 P: 303.872.0487 E:david@vegaarchitecture.com
CIVIL ENGINEER:
Anderson & Hastings Consultants, Inc.
7175 West Jefferson Avenue, Suite 4350 Lakewood, CO 80235 CONTACT: Charles Beck P: 720.452.0527 E: cbeck@ahceinc.com
SEPTIC ENGINEER:
Church Onsite Wastewater Consultants P.O. Box 18796 Golden, CO 80402 CONTACT: Kate Carney P: 720.898.3434 E: kcarney@cowc.info
STRUCTURAL ENGINEER:
Portis Structural Design 1001 Bannock St.. Ste 441 Denver, CO 80204 CONTACT: Jon Eldridge P: 720.501.4900 E: jon@portisdesign.com
MECHANICAL ENGINEER:
MEC Inc.
4640 N Pecos St, Unit F Denver, CO 80211 CONTACT: Joe Wittenberg P: 914.860.6507 E: jwittenberg@mecengr.com
PLUMBING ENGINEER:
MEC Inc.
4640 N Pecos St, Unit F Denver, CO 80211 CONTACT: Joe Wittenberg P: 914.860.6507 E: jwittenberg@mecengr.com
ELECTRICAL ENGINEER:
D.Keller Electrical Design 7498 W Layton Pl Littleton, CO 80123 CONTACT: Dawn Keller P: 303.918.9475 E: dawn@dkellereng.com
GEOTECH ENGINEER
Terracon 4172 Center Park Drive Colorado Springs, CO 80909 P: 719.597.2116 E: Terracon.com
LAND SURVEYOR
Anderson & Hastings Consultants, Inc.
7175 West Jefferson Avenue, Suite 4350 Lakewood, CO 80235 CONTACT: James V. Hastings P: 720.433.8486
THE FOLLOWING APPROVED BUILDING CODES AND STANDARDS HAVE BEEN
ADOPTED BY STATE BUILDINGS PROGRAMS (SBP) AS THE MINIMUM
REQUIREMENTS TO BE APPLIED TO ALL STATE-OWNED BUILDINGS AND
PHYSICAL FACILITIES INCLUDING CAPITAL CONSTRUCTION AND CONTROLLED
MAINTENANCE CONSTRUCTION PROJECTS.
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL FIRE CODE (IFC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2023 NATIONAL ELECTRICAL CODE (NEC)
2021 INTERNATIONAL PLUMBING CODE (IPC)
2021 INTERNATIONAL FUEL GAS CODE (IFGC)
THE NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS (NFPA)
THE 2017 EDITION OF ICC/ANSI A117.1
ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
ANSI/ASHRAE/IES STANDARD 90.1 - 2010/2013
ENERGY STANDARD FOR BUILDINGS
COLORADO MODEL ELECTRIC READY AND SOLAR READY CODE
NOT IN CONTRACT — FOR INFORMATION ONLY
levinsonr Text Box
EXISTING ITS FIBER AS-BUILTS - FOR INFORMATION ONLY
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
1. ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO CDOT M&S STANDARDS AND SPECIFICATIONS, CURRENT EDITION. ALL MATERIALS AND WORKMANSHIP SHALL BE SUBJECT TO INSPECTION BY CDOT. CDOT RESERVES THE RIGHT TO ACCEPT OF REJECT ANY MATERIALS AND WORKMANSHIP THAT DOES NOT CONFORM TO THEIR STANDARDS AND
SPECIFICATIONS.
2. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS AT AND ADJACENT TO THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS.
3. THE METHODS OF CONSTRUCTION SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND THEIR SUBCONTRACTORS. THE CONTRACTORS SHALL TAKE ALL REASONABLE PRECAUTIONS TO PROTECT WORK IN PROGRESS, HIS PERSONNEL AND VISITORS TO THE SITE FROM SOURCES OF INJURY. SUCH PRECAUTIONS SHALL INCLUDE BUT ARE NOT LIMITED TO: ERECTION OF BARRIERS, SHORING AND/OR BRACING OF EXCAVATIONS AND PROTECTION OF WORK IN PLACE
FROM INTRUSION BY TRESPASS OR WEATHER.
4. CDOT'S/ ENGINEER'S CONSTRUCTION REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR’S SAFETY MEASURES IN, ON OR NEAR THE CONSTRUCTION SITE.
5. TRENCHES AND OPEN EXCAVATIONS SHALL BE APPROPRIATELY MARKED AND PROTECTED BY THE CONTRACTOR. NO TRENCHES OR EXCAVATIONS SHALL REMAIN UNPROTECTED OVERNIGHT. CONTRACTOR SHALL PROVIDE PROTECTION SUFFICIENT TO MAINTAIN PUBLIC SAFETY, IN ACCORDANCE WITH COSTILLA COUNTY AND OSHA REGULATIONS AS WELL AS
THE REQUIREMENTS OF CDOT.
6. THE CONTRACTOR SHALL HAVE ONE SIGNED COPY OF THE APPROVED PLANS AND ONE COPY OF THE APPROPRIATE DESIGN AND CONSTRUCTION STANDARDS AND SPECIFICATIONS ON THE JOB SITE AT ALL TIMES.
7. CONTRACTOR IS RESPONSIBLE FOR CONTROL OF EROSION OF ALL AREAS OF CONSTRUCTION THROUGH THE USE OF SILT FENCE, ROCK SOCKS, ETC. PROVIDE ROCK SOCK BARRIERS ACROSS DITCHES AND INLETS NEAR TRENCH EXCAVATION.
8. ALL CONSTRUCTION ACTIVITIES SHALL COMPLY WITH THE CDOT STORMWATER MANAGEMENT (SWMP) NOTEBOOK
PREPARED FOR THE PROJECT SITE.
9. EXISTING TOPOGRAPHY SHOWN WAS TAKEN FROM A FIELD SURVEY CONDUCTED IN AUGUST 2024. BENCHMARK
ELEVATIONS AND DATUM ARE AS NOTED.
10. EXISTING UTILITIES SHOWN ARE BASED ON THE BEST INFORMATION AVAILABLE TO THE ENGINEER. PRIOR TO EXCAVATING, THE CONTRACTOR SHALL FIELD LOCATE (INCLUDING DEPTHS) BY POTHOLING ALL EXISTING UTILITIES WHICH
MAY CONFLICT WITH THE PROPOSED CONSTRUCTION.
11. THE CONTRACTOR SHALL PROVIDE THE OWNER AND ENGINEER WITH A FIELD SHEET INDICATING THE LOCATION AND DEPTH OF ALL UTILITIES VERIFIED BY POTHOLING WITHIN 2 BUSINESS DAYS OF COMPLETING THE POTHOLING AND PRIOR TO
COMMENCING WORK IN THE VICINITY OF UTILITIES VERIFIED BY POTHOLING.
12. IF THE CONTRACTOR DISCOVERS ANY CONFLICT BETWEEN THE DESIGN LOCATION OF WORK UNDER THIS CONTRACT
AND AN EXISTING UTILITY HE SHALL NOTIFY THE OWNER AND THE ENGINEER IMMEDIATELY.
13. IF THE CONTRACTOR ENCOUNTERS ANY UNDOCUMENTED LINES, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE
OWNER AND NOTIFY THE ENGINEER SO THAT ANY CONFLICTS CAN BE MITIGATED.
14. ALL EXISTING UTILITIES SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE REPAIR OF DAMAGE TO UTILITIES SHOWN HEREON AT THIER OWN EXPENSE.
15. EXISTING FENCES, SITE IMPROVEMENTS AND STRUCTURES SHALL BE PROTECTED FROM CONSTRUCTION RELATED
DAMAGE. CONTRACTOR SHALL CORRECT OR RESTORE SUCH DAMAGE AT CONTRACTOR'S EXPENSE.
16. IF DEWATERING IS REQUIRED, A STATE CONSTRUCTION DEWATERING PERMIT IS REQUIRED FOR DISCHARGES TO A STORM SEWER, CHANNEL, OR ANY ROADWAY THAT IS A TRIBUTARY TO THE AFOREMENTIONED FACILITIES, OR ANY WATERS
OF THE UNITED STATES.
17. THE CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING LINE AND GRADE, IN CONFORMANCE WITH THE INFORMATION SHOWN ON THE PLANS, FOR ALL FACILITIES TO BE CONSTRUCTED AS PART OF THE SCOPE OF THE PROJECT. THIS INCLUDES RESTORING TO THEIR ORIGINAL LINE AND GRADE ALL SITE IMPROVEMENTS THAT ARE REMOVED AND REPLACED AS PART OF THIS PROJECT. THE ENGINEER OR OWNER MAY, FROM TIME TO TIME, CHECK THE LINE AND GRADE OF COMPLETED SECTIONS OF THE WORK OR SECTION OF THE WORK IN PROGRESS. THIS, HOWEVER, IN NO WAY RELIEVES THE CONTRACTOR OF THEIR RESPONSIBILITY IN ESTABLISHING THE LINE AND GRADE OF THE WORK IN CONFORMANCE WITH THE
PLANS.
18. THE CONTRACTORS SHALL FULLY FAMILIARIZE HIM/HER SELF WITH THE REQUIREMENTS AS REPRESENTED IN THE DRAWINGS AND WITH THE CONDITIONS AT THE SITE. NO ADDITIONAL COSTS TO THE OWNER SHALL BE ACCEPTED FOR
ADDITIONAL WORK FOR FORESEEABLE OR EXISTING CONDITIONS.
19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER DISPOSAL OF ALL TRASH, DEBRIS AND EXCAVATED
MATERIAL GENERATED AS A RESULT OF HIS/HER WORK.
20. THE CONTRACTOR SHALL ADHERE TO THE OWNER'S REQUIREMENTS FOR CONSTRUCTION PARKING AND SHALL REQUIRE THAT THEIR EMPLOYEES AND ALL SUB-TRADE EMPLOYEES PARK ONLY IN DESIGNATED AREA(S). THE OWNER'S CONTACT WILL ADVISE THE CONTRACTOR ON THE SPECIFICS OF THESE REQUIREMENTS AT THE PRE-CONSTRUCTION
MEETING.
21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING THE RIM OF ALL EXISTING AND PROPOSED MANHOLES, CLEANOUTS AND INLETS TO FINISHED GRADE.
22. THE CONTRACTOR SHALL BE RESPONSIBLE FOR EXPORTING AND DISPOSAL OF EXCESS EXCAVATED MATERIAL OR
THE IMPORT OF FILL MATERIAL AS REQUIRED BY THE GRADING PLANS.
23. THIRD PARTY TESTING SHALL BE PERFORMED BY THE GEOTECHNICAL ENGINEER OF RECORD AND PAID FOR BY THE CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE GEOTECHNICAL ENGINEER TO
SCHEDULE ALL TESTING AND OBSERVATION REQUIRED BY THE PROJECT DOCUMENTS.
24. ALL EARTHWORK AND GRADING TO BE IN CONFORMANCE WITH THE GEOTECHNICAL ENGINEERING STUDY, PREPARED
BY GROUND ENGINEERING DATED JULY 10, 2024, PROJECT #24-6003.
25. SITE BENCHMARK: SITE NORTHWEST PROPERTY CORNER - FOUND 2 12" ALUM. CAP ON REBAR LABELED 78.24' W.C. TO
S 1/16 COR. SEC. 21/22 PLS#32434
ELEV.= 7905.84 NAVD 88
26. WORK WITHIN CDOT ROW TO BE PERFORMED IN ACCORDANCE WITH APPLICABLE STATE OF COLORADO STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION AND MAY REQUIRE A CDOT SPECIALTY USE PERMIT (SUP).
27. DURING ALL SUBSURFACE ACTIVITIES, WORKERS SHALL BE ALERT FOR VISUAL AND OLFACTORY SIGNS OF CONTAMINATION. IF CONTAMINATION IS ENCOUNTERED, WORK SHALL STOP AND PROCEDURES ESTABLISHED IN THE CDOT 250 SPEC SHALL BE FOLLOWED. ANY CONTAMINATED SOILS OR LANDFILL MATERIAL SHALL BE PROPERLY HANDLED AND
SAMPLED PRIOR TO DISPOSAL.
GENERAL NOTES
0.43%
41.5
41.5
41.5
ME
BIOLOGICAL COMMENTS
TO ENSURE COMPLIANCE WITH THE MBTA AND PREVENT UNANTICIPATED IMPACTS TO WILDLIFE DURING CONSTRUCTION
ACTIVITIES (I.E.DEMOLITION, GRADING), THE FOLLOWING CONDITIONS SHOULD BE MET:
· STAGING AREAS FOR CONSTRUCTION EQUIPMENT AND MATERIALS WILL UTILIZE PREVIOUSLY DISTURBED AREAS SUCH
AS MAINTENANCE YARD, ROADS, GRAVELED PARKING AREAS, AND SHOULDER PULL OUTS.
· CONSTRUCTION ACTIVITIES WILL BE LIMITED TO DAYLIGHT HOURS. NO NIGHTTIME WORK WILL BE ALLOWED IN ORDER
TO MINIMIZE IMPACTS TO WILDLIFE
C000
C
IV
IL
C
O
VE
R S
H
EE
T
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C001
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
PL
AN
MW
MW
EX. SHED
EXIST.
BLDG
EXIST.
SAND
SHED
EXIST.
BLDG
EX. MAG
CONTAINMENT
REMOVE ASPHALT AS
NEEDED TO INSTALL NEW
WATER LINE, ADJUST SIZE
AS REQUIRED
SAWCUT LINE, TYP.
BUILDING TO BE
REMOVED BY
CONTRACTOR AFTER
COMPLETION OF NEW
VSF BUILDING
STRUCTURES TO REMAIN,
PROTECT FROM DAMAGE,
TYP.
REMOVE FENCE AS
NEEDED TO INSTALL NEW
GATE, ADJUST SIZE AS
REQUIRED
CDOT WILL SEAL AND
ABANDON ALL
MONITORING WELLS IN
PLACE PRIOR TO
CONSTRUCTION.
CONTRACTOR DOES NOT
NEED TO PROTECT OR
MAINTAIN AND SHOULD
PAVE OVER THEM
IN-PLACE
BUILDING TO BE
REMOVED BY
CONTRACTOR AFTER
COMPLETION OF NEW
VSF BUILDING
SHED TO REMAIN,
PROTECT FROM
DAMAGE, TYP.
REMOVE EXIST. GATE &
FENCE AS NEEDED TO
INSTALL NEW POWERED
SLIDE GATE
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C002
D
EM
O
LI
TI
O
N P
LA
N
EX. SHED
EXIST.
SAND
SHED
EX. MAG
CONTAINMENT
ED
G
E O
F
PA
VE
M
EN
T
ED
G
E O
F
PA
VE
M
EN
T
7-BAY VSF BUILDING
FF=7903.50
EV
EV
EV
EV
LP
LP LP
LP
LP
LP
LP
LP
LP
LP
W
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C100
O
VE
R
AL
L
SI
TE
P
SAND
SHED
EX. MAG
CONTAINMENT
7-BAY VSF BUILDING
FF=7903.50
ON-SITE WASTEWATER
TREATMENT AREA
WATER QUALITY SAND
FILTER TREATMENT
AREA
(2) 10' MANUAL GATES
6' CHAINLINK
FENCE WITH
BARBED WIRE,
TYP.
CATCH TYPE
CURB & GUTTER,
TYP.
CATCH TYPE
CURB & GUTTER,
TYP.
WASH BAY
TREATMENT
SYSTEM, RE: WTS
PLANS, TYP.
PROPANE TANKS ON
CONC. PAD WITH BOLLARD
PROTECTION, ADJUST SIZE
AS NEEDED, RE: MECH.
FUEL ISLAND PAD,
EQUIPMENT TO BE
PROVIDED BY
OWNER
.2
2'
FULL DEPTH
ASPHALT PATCH,
TYP.
(2) 10' MANUAL GATES
30' POWERED SLIDE
GATE W/ INTEGRAL
MAN GATE & LOOP
DETECTORS FOR EXIT
DATA PED. FOR GATE,
RE: ELEC.
CARD READER W/
BOLLARD
PROTECTION
EV
WHITE STRIPING, TYP.
EV PARKING
STRIPING & SIGNAGE
MOUNTED ON FENCE,
TYP.
USED OIL TANK ON CONC.
PAD WITH BOLLARD
PROTECTION, RE: STRUCT.
6' CHAINLINK
FENCE WITH
BARBED WIRE,
TYP.
6' CHAINLINK
FENCE WITH
BARBED WIRE,
TYP.
6' CHAINLINK
FENCE WITH
BARBED WIRE,
TYP.
TIE NEW FENCE
INTO EXIST., TYP.
TIE NEW FENCE
INTO EXIST., TYP.
8" CONCRETE
PAVEMENT, TYP.
4" ASPHALT
PAVEMENT ON
6" ABC, TYP.
4" ASPHALT
PAVEMENT ON
6" ABC, TYP.
4" ASPHALT
PAVEMENT ON
6" ABC, TYP.
4" ASPHALT
PAVEMENT ON
6" ABC, TYP.
CONC. PAD FOR
GENERATOR (TO BE
PROVIDED BY OWNER)
WITH BOLLARD
PROTECTION, RE: STRUCT.
EV
EV
EV
EV PEDESTAL WITH
BOLLARD PROTECTION,
RE: ELEC.
LP
WBTS CONNEX BOX ON 8" CONCRETE
PAVEMENT EXTENDING A MINIMUM
OF 12" BEYOND BOX EXTENTS, FIELD
VERIFY BOX DIMENSIONS PRIOR TO
INSTALLATION, TYP.
5'
CLEAR
TYP.
BOLLARD PROTECTION AT
CORNERS OF CONNEX BOX, TYP.
FULL DEPTH
ASPHALT PATCH,
TYP.
5' CLEAR TYP.
INTEGRATE FENCE
IN TOP OF WALL,
TYP.
12" WIDE CURB
OPENING WITH 25
SF TYPE M
RIPRAP, TYP
12" WIDE CURB
OPENING WITH 25
SF TYPE M
RIPRAP, TYP
POND
EMERGENCY
OVERFLOW, 3'-0"
WIDE CURB
OPENING WITH 25
SF TYPE M
RIPRAP, TYP
LP
SITE LIGHTING,
RE: ELEC., TYP. LP
LP
LP
SITE LIGHTING,
RE: ELEC., TYP.
LP
SITE LIGHTING,
RE: ELEC., TYP.
LP
SITE LIGHTING,
RE: ELEC., TYP.
LP
SITE LIGHTING,
RE: ELEC., TYP.
LP
SITE LIGHTING,
RE: ELEC., TYP.
LP
SITE LIGHTING,
RE: ELEC., TYP.
CONCRETE WALL
SURROUNDING SAND
FILTER, RE: SHEET C502
TOP OF WALL=7900.73
TOP OF SAND=7898.23
MAX WALL HEIGHT=2.5'
NOTE: RE DETAIL 5/C500
FOR BOLLARD DETAIL
W
4' O.C.
MAX.
TYP.
4' O
.C
M
AX
TY
P.
4' O
.C
M
AX
TY
P.
4' O.C. MAX. TYP
4' O
.C
M
AX
4' O
.C
M
AX
TY
P.
4' O.C.
MAX.
TYP.
2' O
.C
M
AX
3.67' TYP. 16.33', TYP.
REFER TO EXPANDED
SITE PLAN, THIS SHEET
4' O
.C
M
AX
TY
P.
4' O.C.
MAX.
TYP.
72.65'
.0
2'
7.31'
EV
ACCESSIBLE PARKING
+ VAN ACCESSIBLE
SIGNS MOUNTED ON
BUILDING
EV PEDESTAL WITH
BOLLARD PROTECTION,
RE: ELEC.
CONC. WHEELSTOP
ACCESSIBLE
STRIPING SYMBOL
WHITE STRIPING, TYP.
EV PARKING
STRIPING & SIGNAGE
MOUNTED ON
BUILDING, TYP.
DIAGONAL WHITE
STRIPING @ 2' O.C.,
TYP
5.
.0 0'
8.00' 8.00' 8.00'
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C101
SI
TE
P
LA
EXPANDED SITE PLAN
SHED
EX. MAG
CONTAINMENT
7-BAY VSF BUILDING
EV
EV
EV
EV
LP
LP LP
LP
LP
LP
LP
LP
LP
LP
W
1 10
11 12
2324 25
49 50
5152 53 54
57 58
Point Table
Point #
Northing
1275155.79
1275154.95
1275135.13
1275084.42
1275085.84
1275136.55
1275155.76
1274936.75
1274940.48
1275155.47
1275155.73
1275155.70
1275027.16
1275047.16
1275322.50
1275264.85
1275270.78
1275268.87
1275257.86
1275152.08
Easting
3021046.48
3022290.18
3021271.39
3021271.83
3021434.53
3021434.09
3021094.73
3021096.64
3021525.63
3021523.76
3021147.97
3021168.03
3021524.88
3021524.70
3021102.02
3021101.47
3021043.76
3021056.68
3021122.77
3021125.22
Description
SITE BENCHMARK
NE PROP CORNER
BUILDING CORNER
BUILDING CORNER
BUILDING CORNER
BUILDING CORNER
FENCE END
FENCE CORNER
FENCE CORNER
FENCE CORNER
GATE
GATE
GATE
GATE
LIGHTPOLE
LIGHTPOLE
WATER TAP
WATER VALVE
WATER LINE
WATER LINE
Point Table
Point #
Northing
1275148.77
1275379.16
1275342.57
1275020.76
1274949.75
1274952.00
1274953.04
1274953.48
1275061.42
1275061.63
1275064.91
1275066.24
1275097.24
1275087.72
1275087.72
1275129.72
1275129.72
1275139.42
1275139.42
1275149.42
Easting
3021302.93
3021070.84
3021241.20
3021100.71
3021096.53
3021355.63
3021474.25
3021525.52
3021272.03
3021296.03
3021296.00
3021439.70
3021439.43
3021461.25
3021475.25
3021475.25
3021461.25
3021505.74
3021517.74
3021517.74
Description
WATER LINE
LIGHTPOLE
LIGHTPOLE
LIGHTPOLE
CURB FL END
CURB OPENING
CURB OPENING
CURB FL END
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
Point Table
Point #
Northing
1275149.42
1275270.74
1275270.74
1275316.74
1275316.74
1275153.64
1275102.39
1274956.50
1274954.79
1275184.22
1274951.97
1274938.97
1274940.06
1274953.06
Easting
3021505.74
3021096.56
3021123.06
3021123.06
3021096.56
3021205.92
3021518.12
3021455.76
3021279.95
3021053.72
3021352.48
3021352.55
3021477.49
3021477.38
Description
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
CONC CORNER
LIGHTPOLE
LIGHTPOLE
LIGHTPOLE
LIGHTPOLE
LIGHTPOLE
SAND FILTER
SAND FILTER
SAND FILTER
SAND FILTER
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C110
H O
R
IZ
O N
TA
L
C O
N
TR
O L
SHED
EX. MAG
CONTAINMENT
SITE BENCHMARK:
FOUND 2 12" ALUM. CAP ON REBAR
LABELED 78.24' W.C. TO S 1/16 COR.
SEC. 21/22 PLS#32434
ELEV. = 7905.84 NAVD 88
ED
G
E O
F
PA
VE
M
EN
T
7-BAY VSF BUILDING
FF=7903.50
03.50
03.10 03.10
2.
0%2.
0%
7902.81 7901.73 7901.23
7900.83 79
.2
.2
2.
0%
1.0%1.0% 1.0%1.0% 2.0%
7905.05 ME
7905.25 ME
1.
1%
1.
1%
EV
EV
EV
EV
LP
03.04
.04
03.50 03.50
03.50 03.40
05.86 HP
05.05
04.82 ME
7900.50 ME
7900.737901.50
M.E.
M.E.
M.E.
M.E.
M.E.
M.E.
M.E.
M.E.M.E.
M.E.
M.E.
M.E.
M.E.
M.E.
03.22 03.05
03.89
04.03
TOC=05.38
(4" ABOVE
GRADE, TYP)
1.0% 1.0%
3.
1%
4.
0%
TOC=05.38
(4" ABOVE
GRADE, TYP)
2.
0%
1.0%
1.2%
04.55
05.05
04.55
05.36 HP
5% 5%
5%
5%
.7
7900.737900.73
7900.73
7900.73
7900.23
.7
.2
.73
.23
7900.73
7900.23
03.30
04.85
2.0%
03.30
04.85
LP LP
LP
LP
LP
LP
LP
LP
W
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C200
G R
AD
IN
G P
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
1. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND IMPLEMENTING AND MAINTAINING EROSION AND SEDIMENT CONTROL MEASURES AT ALL TIMES DURING CONSTRUCTION TO PREVENT DAMAGING FLOWS ON THE SITE AND IN THE WATERSHED BELOW THE SITE. CONTROL SYSTEMS SHALL BE INSTALLED PRIOR TO START OF CONSTRUCTION. CONTROL SYSTEMS SHALL INCLUDE GRAVEL
BAG ROCK SOCKS, SILT FENCES AND INLET PROTECTION DEVICES.
2. THE CONTRACTOR SHALL PROVIDE ANY ADDITIONAL DUST ABATEMENT AND EROSION CONTROL MEASURES AS SPECIFIED BY THE SWMP.
3. THE CONTRACTOR SHALL PREVENT SEDIMENT, DEBRIS AND ALL OTHER POLLUTANTS FROM LEAVING THE SITE DURING ALL DEMOLITION, EXCAVATION, TRENCHING, GRADING OR OTHER CONSTRUCTION OPERATIONS THAT ARE PART OF THIS PROJECT. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR REMEDIATION OF ANY ADVERSE IMPACTS TO ADJACENT WATERWAYS, WETLANDS, ETC., RESULTING FROM WORK DONE
AS PART OF THIS PROJECT.
4. THE CONTRACTOR SHALL INSURE THAT ALL LOADS OF CUT AND FILL MATERIAL IMPORTED TO OR EXPORTED FROM THE SITE SHALL BE PROPERLY COVERED TO PREVENT LOSS OF THE MATERIAL DURING TRANSPORT ON PUBLIC ROADS.
5. APPROVED EROSION AND SEDIMENT CONTROL “BEST MANAGEMENT PRACTICES” (BMP’S) SHALL BE MAINTAINED AND KEPT IN GOOD REPAIR FOR THE DURATION OF THE PROJECT. AT A MINIMUM, THE CONTRACTOR OR THEIR SWMP ADMINISTRATOR SHALL INSPECT ALL BMPS WEEKLY AND AFTER SIGNIFICANT PRECIPITATION EVENTS. ALL NECESSARY MAINTENANCE AND REPAIRS SHALL BE COMPLETED WITHIN 48 HOURS OF DISCOVERY. ACCUMULATED SEDIMENT AND DEBRIS SHALL BE REMOVED FROM A BMP WHEN THE SEDIMENT LEVEL REACHES ONE HALF THE HEIGHT OF THE BMP OR, AT ANY TIME THAT SEDIMENT OF DEBRIS ADVERSELY IMPACT THE FUNCTIONING OF THE BMP.
6. THE CONTRACTOR SHALL PROTECT ALL STORM SEWER FACILITIES ADJACENT TO ANY LOCATION WHERE PAVEMENT SAW CUTTING OPERATIONS ARE TO TAKE PLACE. THE CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE OF ALL WASTE PRODUCTS GENERATED BY THE CUTTING OPERATIONS ON A DAILY BASIS. THE DISCHARGE OF ANY WATER CONTAMINATED BY WASTE PRODUCTS FROM CUTTING OPERATIONS
TO THE DRAINAGE SYSTEM IS PROHIBITED.
7. PAVED SURFACES ADJACENT TO THE SITE SHALL BE SWEPT IN A TIMELY MANNER WHEN SEDIMENT AND OTHER MATERIALS ARE TRACKED OR DISCHARGED ONTO THEM. EITHER SWEEPING BY HAND OR USE OF STREET SWEEPERS IS ACCEPTABLE. STREET SWEEPERS USING WATER WHILE SWEEPING IS PREFERRED TO MINIMIZE DUST. FLUSHING OFF PAVED SURFACES WITH WATER IS PROHIBITED.
8. EROSION/SEDIMENT CONTROL DEVICES PER SWMP PLANS SHALL BE PLACED AS CONSTRUCTION SEQUENCING AND ACCESS DICTATES.
9. ALL INLETS WITHIN THE CONSTRUCTION AREA TO BE PROVIDED INLET PROTECTION DURING CONSTRUCTION.
GRADING AND EROSION CONTROL NOTES
0.43%
41.5
41.5
41.5
ME
C300
SW
M
P C
O
VE
R S
H
EE
T
SAND
SHED
EX. MAG
CONTAINMENT
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C301
IN
IT
IA
L
SW
M
P
SAND
SHED
EX. MAG
CONTAINMENT
7-BAY VSF BUILDING
EV
EV
EV
EV
LP
LP LP
LP
LP
LP
LP
LP
LP
LP
W
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C302
IN
TE
R
IM
S W
M P
SAND
SHED
EX. MAG
CONTAINMENT
7-BAY VSF BUILDING
EV
EV
EV
EV
LP
LP LP
LP
LP
LP
LP
LP
LP
LP
W
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C303
FI
N
AL
S
W M
P
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C304
SW
M
P D
ET
AI
LS
(1
O F
2)
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C305
SW
M
P D
ET
AI
LS
(2
O F
2)
SHED
EX. MAG
CONTAINMENT
PP
PP
W
ED
G
E O
F
PA
VE
M
EN
T
7-BAY VSF BUILDING
FF=7903.50
EV
CONNECT 1.5" TYPE K
COPPER TO BUILDING,
RE: PLUMBING
SANITARY SEWER SERVICE
LINE, RE: ONSITE
WASTEWATER TREATMENT
PLANS & PLUMBING, TYP.
SANITARY SEWER
TREATMENT AREA, RE:
ONSITE WASTEWATER
TREATMENT PLANS &
PLUMBING, TYP.
379.2 LF 1.5" TYPE K
COPPER, TYP.
1.5" TAPPING SADDLE
13.2 LF 1.5" TYPE K COPPER
1.5" CURB STOP
EV
EV
EV
LP
WASH BAY
TREATMENT
SYSTEM, RE: WTS
PLANS, TYP.
30' POWERED SLIDE
GATE W/ INTEGRAL
MAN GATE & LOOP
DETECTORS FOR EXIT
DATA PED. FOR GATE,
RE: ELEC.
CARD READER W/
BOLLARD
PROTECTION
GAS LINE TO BUILDING BY
PROPANE COMPANY, TYP.
LP LP
LP
LP
LP
LP
LP
LP
W
WATER METER IN VAULT
APPROXIMATE
LOCATION OF MAIN
ELECTRICAL SERVICE
PANNEL, RE: ELEC.
HEAT PUMPS ON PAD,
RE: MECH.
WASTE OIL TANK,
RE: STRUCT.
CONC. PAD FOR
GENERATOR (TO BE
PROVIDED BY OWNER)
WITH BOLLARD
PROTECTION, RE: STRUCT.
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C400
U
TI
LI
TY
P
TACK COAT
2.5" LIFT-GRADE S, N=100 OR APPROVED EQUAL
1.5" LIFT-GRADE SX, N=75 OR APPROVED EQUAL
8" THICK AGGREGATE
BASE COURSE
BINDER=64-22 OR APPROVED EQUAL
4"R
4"R
DETAIL 1 DETAIL 2
(LONGITUDINAL OR TRANSVERSE)
1" DIA. SMOOTH BAR DOWEL x
1'-2 LONG SPACED @ 12" O.C.
ONE SIDE LUBRICATED.
(LONGITUDINAL OR TRANSVERSE)
(10' MAX. SPACING)
SAWCUT
JOINT SEALANT DETAILS, DETAIL 1FILL JOINTS TO WITHIN 1/8"
OF SURFACE WITH JOINT
SEALANT TYP.
6" THICK
AGGREGATE BASE
COURSE
6" THICK
AGGREGATE
BASE COURSE
JOINT SEALANT
DETAILS, DETAIL 2
8" PORTLAND CEMENT
CONCRETE
6" THICK AGGREGATE
BASE COURSE
SUBGRADE PREP. PER
GEOTECHNICAL REPORT
3' -0
1"
18" DIA.
3' -6
3' -0
6" 1"
SUBGRADE PREP. PER
GEOTECHNICAL
REPORT
SUBGRADE PREP. PER
GEOTECHNICAL
REPORT
SUBGRADE PREP. PER
GEOTECHNICAL
REPORT
#5 @ 16" EACH WAY
6"
12"
6"
CURB AND GUTTER
RIPRAP CHANNEL
NOT TO SCALE,
RE: PLAN
N.T.S.
SHAPE
& TEXT SIZESIGN # MUTCD
SIGN
NUMBER
30"x30"1 R1-1
12"x18"2 R7-128
6"x12"3 R7-8PVAN
ACCESSIBLE
N.T.S.
BOLLARD DETAIL5
SIGN MOUNTING AND SCHEDULE7
TYPICAL EV STATION PAINT PATTERN8
NOTES:
1. PRIOR TO PLACING PAVEMENT MARKINGS CLEAN SURFACE IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
2. APPLY WATER BASED FLEXIBLE PAINT (MPI NO. 97) AND EV
PATTERN AT EACH EV SPACE AS INDICATED IN THE TYPICAL
PATTERN ABOVE. GREEN FOR EV SPACE, WHITE FOR STRIPING
AND EV PATTERN.
3. BASIS OF DESIGN: US SPECIALITY COATINGS STAMPCRETE EV OR
APPROVED EQUAL.
12"x18"4 CUSTOM
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C500
C
IV
IL
D
ET
AI
LS
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C501
C D
O T
D
ET
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C502
C D
O T
D
ET
NOT TO SCALE
124'-0"
'-8
8" TYP. WALL
THICKNESS
NOT TO SCALE
8"
NOT TO SCALE
RIPRAP CROSS SECTION
TOP OF WALL/BERM=7900.73
SAND FILTER OVERFLOW
EL.=7899.73
#4 @ 10" EA. WAY
NOT TO SCALE
NOT TO SCALE
SAND FILTER WALL CROSS SECTION
DRAWING NUMBER
CDOT PROJECT NO.
23740
DRAWN BY:
PR
O
PE
R
TY
M
AN
AG
EM
EN
T
W
. H O
W
AR
D P
L.
D
EN
VE
R
C O
Ph on e:
-7
-9
FT
G
A R
LA
N
D
+1 B
A Y
VS
F
H
IG
H
W
AY
FO
R
T G
AR
LA
N D
, C O
LO
R
AD
O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
C O
N
ST
R U
C
TI
O N
D O
C S
C O
N
ST
R U
C
TI
O N
D O
C S
C D
/C O
D E
R
EV
IE
W
R
ES
PO
N
SE
T
O C
O M
M
EN
TS
/1 7/
0%
B
ID
S
ET
D
ES
C R
IP
TI
O N
D
AT
E N
o. 2 3 4 5
0-
/2
3/
/0
3/
/2
3/
/1
8/
C503
PO
N
D D
ET
GENERAL ONSITE WASTEWATER TREATMENT(OWTS) NOTES
DRAWN BY:
DRAWING NUMBER
D A
T E
N o
D
E S
C R
IP
T
IO
N
-7
-9
P R
O P
E R
T Y
M A
N A
G E
M E
N T
W
H
O W
A R
D P
L.
C ol or a do D ep a rt m e nt o f
T ra n sp o rt a tio n
P h o ne
D
E N
V E
R
C O
F T
G A
R
LA
N D
B
A Y
V S
F
H
II
G
H W
A Y
F O
R T
G A
R L
A N
D
C O
L O
R A
D O
KEC
N A
5% C
O N
S T
R U
C T
IO
N
D O
C S
WW-001
5%
C O
N S
T R
U C
T
IO
N D
O C
S 2 3 4
9%
C D
/C O
D E
R E
V
IE
W
R E
S P
O N
S E
T O
C O
M M
E N
T S
O W
T S
N O
T E
S
5/
/2
CDOT PROJECT NO.
26570
B
ID
S E
T
7/
/2
Onsite Wastewater Engineering-Civil Engineering P.O. Box 18796, Golden, CO 80402
Voice: (720) 898-3434
7/
/2
8/
/2
SHED
EX. MAG
CONTAINMENT
7-BAY VSF BUILDING
EV
EV
EV
EV
LP
LP LP
LP
LP
LP
LPW
ON-SITE WASTEWATER
SOIL TREATMENT AREA
1,000-GALLON,
2-COMPARTMENT
CONCRETE
SEPTIC TANK
1,000-GALLON,
SINGLE
COMPARTMENT
CONCRETE FLOW
EQUALIZATION
TANK WITH
DUPLEX PUMPS
1.5" SCHED 40 PVC3' SAND FILTER
WITH 22 ELJEN
MODULES
8'
46'
4" SCHED 40
SANITARY SEWER
WITH CLEANOUT
CONTROL PANEL
TEST PIT 1
TEST PIT 2
SEWER
CLEANOUT
SEWER
CLEANOUT
SCALE: 1" = 20'
N
0 5 10 20 30 50
OWTS NOTES
1. CONNECT 4" PVC TO BUILDING W/
2-WAY CLEANOUT, INV.=7900', RE:
PLUMBING
2. 137 LF 4" PVC @ 2.0% TO SEPTIC TANK 1,
LID=7901', 4" INV. IN=7897', 4" INV.
OUT=7896.75
3. INSTALL 4" SCHED 40 PVC BETWEEN
TANKS.
4. SEPTIC TANK 2 LID=7901, 4" INV.
IN=7896.25, 4" INV. OUT=7896'
5. ORENCO CONTROL PANEL
6. 95 LF 1.5" SCHED 40 PVC
7. STA - FG = 7901-7902', BOT OF ELJEN =
7900.5, BOT OF SAND = 7897.5'
DRAWN BY:
DRAWING NUMBER
D A
T E
N o
D
E S
C R
IP
T
IO
N
-7
-9
P R
O P
E R
T Y
M A
N A
G E
M E
N T
W
H
O W
A R
D P
L.
C ol or a do D ep a rt m e nt o f
T ra n sp o rt a tio n
P h o ne
D
E N
V E
R
C O
F T
G A
R
LA
N D
B
A Y
V S
F
H
II
G
H W
A Y
F O
R T
G A
R L
A N
D
C O
L O
R A
KEC
N A
5% C
O N
S T
R U
C T
IO
N
D O
C S
WW-100
5%
C O
N S
T R
U C
T
IO
N D
O C
S 2 3 4
9%
C D
/C O
D E
R E
V
IE
W
R E
S P
O N
S E
T O
C O
M M
E N
T S
O W
T S
S
IT
E P
LA
N
5/
/2
CDOT PROJECT NO.
26570
Onsite Wastewater Engineering-Civil Engineering P.O. Box 18796, Golden, CO 80402
Voice: (720) 898-3434
Onsite Wastewater Consultants
7/
/2
7/
/2
B
ID
S E
T
8/
/2
ELECTRICAL REQUIREMENTS
TWO 230V, 20-AMP CIRCUIT FOR
PUMPS
ONE 115V, 10-AMP CIRCUIT FOR
CONTROLS
FLOAT ELEVATION SETTINGS:
SET THE OVERRRIDE FLOAT ACTIVATION
ELEV 3-INCHES BELOW THE TANK INLET
ELEVATION.
SET THE HIGH WATER ALARM FLOAT
ACTIVATION ELEV 5-INCHES BELOW THE
TANK INLET ELEVATION.
SET THE TIMER ON/OFF FLOAT
ACTIVATION ELEVATION 3-INCHES
ABOVE THE LOW WATER ALARM ELEV.
SET THE REDUNDANT OFF/LOW WATER
ALARM FLOAT ACTIVATION ELEV
26-INCHES ABOVE THE BOTTOM OF THE
TANK.
LIQUID LEVEL
DISCHARGE PIPE TO STA
COMPACTED BACKFILL SOIL
IN-SITU MATERIAL
FINISHED GRADE
4" SCHED 40
PVC PIPE
CONDUIT; SEE
NOTE 12
LIQUID LEVEL
TANK ADAPTOR
INLET TEE
SLOPE
POSITIVE
1,000 GALLON TRAFFIC RATED SEPTIC TANKS 1,000 GALLON EQUALIZATION TANK
5" BEDDING SAND
REQUIRED
PIPE FROM
GENERAL DOSING TANK NOTES:
1. BIOTUBE PUMP VAULT & HIGH WATER ALARM SHALL BE INSTALLED IN THE SECOND RISER OF THE EQUALIZATION TANK.
2. CONTRACTOR SHALL FURNISH AND INSTALL AN EXTERNAL SPLICE BOXES.
3. ALL EQUIPMENT ACCESS HANDLES SHALL BE EXTENDED TO A MAX OF 12" BELOW BOTTOM OF RISER LID.
4. INSTALLER SHALL INSTALL TWO FRONT RANGE PRECAST SINGLE COMPARTMENT CONCRETE SEPTIC TANKS. ALTERNATE TANK CONFIGURATIONS ARE POSSIBLE WITH
PRIOR WRITTEN APPROVAL OF DESIGN ENGINEER. NO MID-SEAM TANKS SHALL BE ALLOWED.
5. TANKS RISERS AND LIDS SHALL BE FIBERGLASS. LIDS SHALL BE INSULATED WITH 2" OF CLOSED FOAM INSULATION.
6. SLOPE FINISHED GRADE AWAY FROM TANK LIDS AT MIN 5% FOR 5-FEET. MIN SLOPE THEREAFTER IS 2% AWAY FROM TANK.
7. EXTEND ALL RISERS TO FINISHED GRADE.
8. PROOF ROLL SUBGRADE PRIOR TO PLACING BEDDING. COMPACT BEDDING TO MIN 95% MAX DRY DENSITY.
9. PROVIDE EXCAVATION FOR TANK IN ACCORDANCE W/ OSHA REGULATIONS TO FURNISH A SAFE WORKING ENVIRONMENT FOR INSTALLERS.
10. PROVIDE A STABLE SUBGRADE FOR TANK. OVEREXCAVATE ALL SOFT & YIELDING MAT'L. BACKFILL W/ 1/2" MINUS SAND. BACKFILL & COMPACT IN LIFTS TO BOT PIPES
BEFORE INSTALLING PIPES. COMPACT ALL SUBGRADE & SOIL TO MIN 95% MAX DRY DENSITY PER ASTM D698.
11. BACKFILL IN MAX 12" LIFTS AROUND TANK TO BOTTOM OF INLET AND OUTLET PIPES BEFORE PLACING PIPES. BED PIPES BEFORE PLACING.
12. EXTEND CONDUIT FULL LENGTH TO CONTROL PANEL. FURNISH & INSTALL A CONDUIT SEAL PER MFGS INSTRUCTIONS.
CONTROL PANEL
ORENCO SYSTEMS, INC.
(OSI)
MVP-DAX-PT-RO-ETM-CT
20.6 GAL/IN
OVERRIDE FLOAT
TIMER ON/OFF FLOAT
REDUNDANT OFF FLOAT/LOW WATER ALARM
FLEXIBLE HOSE
TANK ADAPTOR (CAST OR BOLTED)
VAULT INLET PORTS
FLOW INDUCER
OSI PF300512 DUPLEX EFFLUENT PUMPS
FILTER CARTRIDGE
DRAIN PORT
FLOAT TREE HANDLE (SEE NOTE 3)
COLD WEATHER DISCHARGE
ASSEMBLYBUILDING
24" FIBERGLASS
RISERS
24" INSULATED FIBERGLASS
LIDS, TYP
HIGH WATER ALARM
BUILDING SEWER CLEANOUT
VENT AND CLEANOUT CAP
TRENCH NOTES:
1. PLACE & COMPACT BEDDING MATERIAL TO BOTTOM OF PIPE ELEVATION BEFORE INSTALLING PIPE.
2. BEDDING SHALL BE IN PLACE, COMPACTED & PIPE INSTALLED AT TIME OF COWC INSTALLATION OBSERVATION.
3. BURY DEPTH MEANS DISTANCE FROM FINISHED GRADE TO THE PIPE CROWN.
4. FOR ALL SITUATIONS WHERE THE MIN PIPE BURY DEPTH PER COUNTY REQUIREMENTS CANNOT BE MET, A MIN OF 1" OF HIGH
DENSITY CLOSED CELL FOAM INSULATION CAN BE SUBSTITUTED FOR EA 12" OF SOIL COVER THAT IS LACKING. A MIN OF 2" OF
FOAM INSULBOARD SHALL BE REQUIRED. STYROFOAM BEAD BOARD IS NOT ACCEPTABLE.
5. MINIMUM INSULATION WIDTH IS 24", CENTERED OVER CROWN OF PIPE.
6. ALL COMPACTION SHALL BE IN ACCORDANCE WITH ASTM D-698. COMPACT FILL & BACKFILL OUTSIDE RIGHT OF WAY TO MIN 90%
MAX DRY DENSITY. COMPACT FILL & BACKFILL INSIDE RIGHT OF WAY TO MIN 95% MAX DRY DENSITY.
BUILDING SEWER/DISCHARGE PIPE SECTION
MATCH EXIST AC PVMT
SAW CUT ASPHALT ONLY.
NO OTHER TYPE CUT
MATCH EXIST LEVELING
COURSE.
MATCH EXIST
GRADE
MATCH EXIST SUB-BASE
SLOPE PER OSHA
REQUIREMENTS
NON-FROST SUSCEPTIBLE
FILL/BACKFILL
1/2" MINUS GRANULAR BEDDING
MAT'L; TYP 6" ALL SIDES PIPE
UNCLASS. FILL/
BACKFILL
SEE NOTES 4 & 5
DEPTH VARIES
BURIED PIPE
CONTROL PANEL
WELD COUNTY DESIGN CALCULATIONS
12 EMPLOYEES X 15 GPD = 180 GPD
5 VISITORS X 5 GPD = 25 GPD
LOADING= Q= 205 GPD
SOIL TYPE R-0, LTAR: 0.8 (TL1)
SOIL TREATMENT AREA = Q/LTAR = 205/0.8 = 257 SF
257 SF/(12 SF/MODULES)= 22 MODULES
2 ROWS OF 11 MODULES = 22 MODULES; 264 SF
ELJEN PRESSURE DOSED BED SOIL TREATMENT AREA
D E
P T
H
F E
E T
TP-1 TP-2
0-31" SANDY LOAM W/ >50% >20MM
ROCK, 7.5YR 4/3
R-2 W/ TYPE 2 MATRIX
31-84" LOAMY SAND W/ >50% >20MM
ROCK, 7.5YR 4/3
R-0
0-23" SANDY LOAM W/ >50% >20MM
ROCK, 7.5YR 4/3
R-2 W/ TYPE 2 MATRIX
23-91" LOAMY SAND W/ >50% >20MM
ROCK, 7.5YR 4/3
R-0
DRAWN BY:
DRAWING NUMBER
D A
T E
N o
D
E S
C R
IP
T
IO
N
-7
-9
P R
O P
E R
T Y
M A
N A
G E
M E
N T
W
H
O W
A R
D P
L.
C ol or a do D ep a rt m e nt o f
T ra n sp o rt a tio n
P h o ne
D
E N
V E
R
C O
F T
G A
R
LA
N D
B
A Y
V S
F
H
II
G
H W
A Y
F O
R T
G A
R L
A N
D
C O
L O
R A
KEC
N A
5% C
O N
S T
R U
C T
IO
N
D O
C S
WW-500
5%
C O
N S
T R
U C
T
IO
N D
O C
S 2 3
9%
C D
/C O
D E
R E
V
IE
W
O W
T S
C O
M P
O N
E N
T D
E T
A
IL
S
5/
/2
CDOT PROJECT NO.
26570
R
E S
P O
N S
E T
O C
O M
M E
N T
S
B
ID
S E
T
7/
/2
Onsite Wastewater Engineering-Civil Engineering P.O. Box 18796, Golden, CO 80402
Voice: (720) 898-3434
7/
/2
8/
/2
23704
B
IM
cl ou d:
v eg aa rc hi te ct ur e
- B
IM
cl ou d S of tw ar e as a
S er vi ce
/P R
O
JE
C
TS
/C D
O T.
Ft G ar la nd /C
D O
T_ Ft
G ar la nd
_A C
.00
.VX
XX
X
A0.1
G E
N E
R A
L N
O
TE
S
S C
H E
D U
LE
S
DRAWN BY: VA
P R
O P
E R
TY
M
A N
A G
E M
E N
T
W
. H O
W A
R D
P L.
D E
N V
E R
C
O
.00
.VX
XX
X
FT
G
A R
LA
N
D
+1 B
AY
V
S F
H
W Y
FO
R
T G
A R
LA
N
D , C
O
LO
R A
D O
, 8
C ol or ad o D ep ar tm en t of
T ra ns po rt at io n
P ho ne : 3
-7
-9 architecture llc 495 w cedar ave denver, co 80223
303.872.0487 vegaarchitecture.com
D E
PA
R
TM
E
N T
O F
TR
A
N S
P O
R
TA
TI
O
N
C O
N S
TR
U
C
TI
O N
D O
C S
C O
N S
TR
U
C
TI
O N
D O
C S
C O
N S
TR
U
C
TI
O N
D O
C S
R E
S P
O N
S E
T O
C O
M M
E N
TS
1 2 3 4
/1
8/
/3
0/
/0
3/
/2
8/
0%
B
ID
S E
T
/1
8/
D
AT
E N o.
D
ES
C
R
IP
TI
O
N
1. ALL WALLS AND PARTITIONS ARE TO BE BUILT PER PARTITION TYPES SHOWN ON THIS SHEET AND
CALLED OUT IN THE PLANS AND SPECIFICATIONS.
2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL ESTABLISH LOCATION OF ALL
PARTITIONS, OPENINGS, EQUIPMENT, ETC.
3. LARGER SCALE DRAWINGS AND DETAILS HAVE PRIORITY OVER SMALLER SCALE DRAWINGS.
4. CONTRACTOR SHALL NOTIFY THE CDOT REPRESENTATIVE OF ANY DISCREPANCIES OR
CONFLICTS IN THE DRAWINGS AND/OR SPECIFICATIONS TO REQUEST AND RECEIVE AN
INTERPRETATION OR CLARIFICATION FROM CDOT REPRESENTATIVE BEFORE PROCEEDING
WITH CONSTRUCTION.
5. CONTRACTOR SHALL VERIFY FIELD CONDITIONS BEFORE PROCEEDING WITH CREATION OF SHOP
DRAWINGS AND CONSTRUCTION.
6. REFER TO CIVIL DRAWINGS FOR GRADE EQUIVALENT OF ARCHITECTURAL ELEVATION OF 100'-0".
7. DISTANCE FROM PERPENDICULAR WALL TO INSIDE FACE OF DOOR JAMB SHALL BE 4 1/2" UNLESS
OTHERWISE NOTED.
8. AT ROOMS WITH FLOOR DRAINS (TOILET ROOMS, MECHANICAL ROOMS, ETC.), FLOOR SHALL SLOPE TO DRAIN. SLOPE FLOOR TO DRAIN AT 1/4 INCH PER FOOT FROM DRAIN. DO NOT EXCEED
SLOPE FOR ACCESSIBILITY PER ICC A117.1. RE: FLOOR SLAB PLAN ON SHEET A2.2
9. PROVIDE FULLY TEMPERED OR LAMINATED SAFETY GLASS WHERE REQUIRED BY ALL
APPLICABLE CODES, REGULATIONS AND LAWS.
10. NOTE USED.
11. GYP BD IS 5/8 INCH THICKNESS U.O.N., PROVIDE TYPE "X" FIRE RATED GYP BD AT TESTED FIRE
ASSEMBLIES.
12. DO NOT PLACE MECHANICAL AND/OR ELECTRICAL DEVICES BACK TO BACK IN SOUND BARRIER
PARTITIONS. ALL DEVICES TO BE PLACED IN SEPARATE STUD SPACES WITH 8" O.C. MIN.
SEPARATION.
13. PROVIDE CEMENTITIOUS TILE BACKER BOARD AT ALL WALLS IN DIRECT CONTACT WITH WATER
AND AT ALL WALLS SCHEDULED TO RECEIVE SCHEDULED CERAMIC OR STONE TILE. AT HUMID
SPACES INCLUDING BUT NOT LIMITED TO TOILET ROOM WALLS, KITCHEN WALLS AND WALLS
ADJACENT TD WATER FEATURES WHERE TILE IS NOT SCHEDULED PROVIDE MOISTURE
RESISTANT GYPSUM BOARD.
14. UON, PARTITIONS ARE DIMENSIONED TO FACE OF GYP BD, FACE OF MASONRY AND TO FACE OF
EXISTING CONSTRUCTION. ANY INTERIOR PARTITIONS DIMENSIONED TO FACE OF METAL STUD
ARE NOTED - "FOS" (FACE OF STUD). DIMENSIONS TO PRE-ENGINEERED METAL
BUILDING COMPONENTS ARE TO FACE OF GIRT OR FACE OF PURLIN.
15. DIMENSIONS TO DOORS AND WINDOWS ARE TO THE CENTERLINE OF THE OPENING. REFER TO
DOOR AND WINDOW SCHEDULE FOR SIZE OF DOORS, WINDOWS, AND FRAMES.
16. PARTITIONS ARE PERPENDICULAR AND/OR PARALLEL TO COLUMN GRID U.O.N.
17. NOTES TO "ALIGN" MEAN TO ALIGN FINISHED FACE OF PARTITION UNLESS OTHERWISE NOTED
AND SHALL HAVE PRIORITY OVER DIMENSIONED LOCATIONS.
18. PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING OR 20 GAUGE METAL BLOCKING AS
SHOWN OR AS REQUIRED FOR ATTACHMENT OF WALL MOUNTED HARDWARE, TOILET
ACCESSORIES, CASEWORK, MILLWORK, FINISH CARPENTRY ETC. AS MAY BE REQUIRED FOR THE
SECURE ATTACHMENT OF ADJOINING WORK
19. PROVIDE STUDS OF GAUGE AND SPACING ADEQUATE TO SUPPORT APPLIED LOADS INCLUDING
HAND-RAILS, KNEE WALLS, GRAB BARS, WALL-MOUNTED FIXTURES, ETC.
20. REFER TO GYPSUM BOARD ASSEMBLIES SPECIFICATION SECTION FOR ADDITIONAL
REQUIREMENTS FOR GYPSUM BOARD ASSEMBLIES INCLUDING, BUT NOT LIMITED TO FIRE RATED
CONSTRUCTION, SOUND RATED CONSTRUCTION, MATERIALS AND TOLERANCES.
21. EXTERIOR ENVELOPE, INCLUDING WALLS, ROOF, FOUNDATION, DOORS AND WINDOWS, SHALL BE
INSULATED TO MEET REQUIREMENTS OF ASHRAE 90.1 STANDARDS IN ACCORDANCE WITH THE
INTERNATIONAL ENERGY CONSERVATION CODE (IECC) FOR CLIMATE ZONE. COMPLIANCE SHALL
BE THROUGH A BUILDING ENVELOPE COMCHECK OR PRESCRIPTIVE APPROACH. CONTRACTOR
TO PROVIDE WALL AND ROOF ASSEMBLIES THAT MEET THE ASSEMBLIES OUTLINED IN
COMCHECK.
22. SOUND INSULATED WALLS SHALL HAVE MINIMUM 3-1/2" SOUND ATTENUATION BATTS AND SHALL
FILL CAVITY WALL COMPLETELY
23. AT METAL BUILDING SYSTEM AND BRAKE METAL INSTALLATION, CLEANLY TERMINATE EDGES
PERPENDICULAR TO PARALLEL WALL OR SURFACE.
24. MAINTAIN 80" HEAD CLEARANCE BELOW ALL DUCTS AND SOFFITS THROUGHOUT THE BUILDING.
AT ANY LOCATIONS THAT DO NOT MAINTAIN CLEARANCE, SUCH AS ACCESS UNDER STAIRS, CANE
DETECTION SHALL PROVIDED IN ACCORDANCE WITH ADA
GENERAL NOTES METAL BUILDING SYSTEMS SCHEDULE OF COLORS AND FINISHES
THE FOLLOWING PRODUCTS ARE METAL BUILDINGS SYSTEMS THAT HAVE HISTORICALLY MET THE
PERFORMANCE REQUIREMENTS AS SPECIFIED. DUE TO POTENTIAL CHANGES MANUFACTURING
PROCESSES, INCLUSION ON THIS LIST DOES NOT GUARANTEE ACCEPTABILITY FOR USE ON THIS PROJECT.