FINAL20201204 Architectural Set.pdf
PDF 12 MB Posted
- Solicitation number
- 36C25821B0012
About this file
This document provides details for a federal contract opportunity with the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22. The solicitation number is 36C25821B0012 and seeks construction services to fully renovate approximately 1200 square feet of an existing Nuclear Medicine department to install a new PET CT scanner. The renovation will be performed according to the attached architectural drawings, statement of work, and specifications. The opportunity type is listed as a solicitation and the description provided indicates the scope of work involves renovating space and installing a new PET CT unit at the medical facility.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P ar ki ng
L ot
E
V
IL
LA
L
A
JO
LL
A
D R
C urve len =Tangent =R adius =D elta =Lot =
#4#3
#7#8
#2
#1
Pedest r i an Br i dge
Length = Bearing =
Length =B earing =
#5
#6
18 9
Gilman Drive
North Road 14 Park ing
Lot - P1 17 19
E as t R oa d
Park ing Lot - H
Par ki ng Lot
Par ki ng Lot
Par ki ng Lot
3 5
South Road
V
IL
LA
L
A
JO
LL
A
D R
LA JOLLA VILLAGE DR
LA JOLLA VILLAGE DR
S A
N D
IE
G
O F
W Y
S A
N D
IE
G
O F
W Y
PAR KI NG
GAR AGE 1
ST RU C TU R E
PAR KI NG
GAR AGE 2
ST RU C TU R E
28 31
KEY PLAN
N
14 17 1913
28 31
BUILDING KEY PLAN
1. INPATIENT/OUTPATIENT AMBULATORY SERVICES
2. BOILER PLANT & CO-GENERATION
3. WEST FLAGPOLE
5. EAST FLAGPOLE
6. GAS METER PAD
8. OXYGEN STORAGE PAD
9. GAS BOTTLE STORAGE
10. BUS SHELTER
11. SPINAL CORD INJURY
12. EMERGENCY WATER STORAGE
N
13. VMRF BUILDING
14. MRI BUILDING
16. HAZARDOUS MATERIAL STORAGE BUILDING
17. FINISHES STORAGE METAL BUILDING
18. WASTE FACILITY
19. HAZARDOUS MATERIAL STORAGE (CONEX BOX)
20. GROUNDS AND STORAGE (CONEX BOXES)
21. UNDERGROUND FUEL STORAGE TANKS
22. SAFETY (MODULAR BUILDING)
23. MRF (MODULAR BUILDING)
27. ADMINISTRATION BUILDING
28. PARKING GARAGE 1
31. PARKING GARAGE 2
ROOM NAME / NUMBER
/ AREA
EXISTING PARTITION /
WALL
DEMO PARTITION / WALL
NEW PARTITION / WALL
EXISTING DOOR
NEW DOOR
DOOR TAG
WINDOW TAG
KEYNOTE
WALL TYPE TAG
INTERIOR ELEVATION
VIEW
DETAIL CALLOUT
DETAIL CUT
WALL SECTION CUT
ROOM NAME
ROOM NUMBER
CEILING HEIGHT
ROOM FINISHES CODE
ROOM AREA
ROOM NAME
150 SF
9'-0"
4501.1
A101
OFFICE
CV-001
996 SF
RF-1 RB-1 P-1 GYP
PL-1
A6.01
A101
A101
SIM
B6
W1
N
A101
8'-0"
FINISH MATERIAL TAG
EQUIPMENT TYPE TAG
CEILING HEIGHT TAG
GRID COLUMN CENTER
LINE
REVISION TAG
ALIGN ARROW SYMBOL
EXIT SIGN ANNOTATION
SYMBOL
SPOT ELEVATION
NORTH ARROW
VIEW TITLE
VIEW NAME
REFERENCE SHEET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:5
P
M
GI-001
COVER SHEET
11/06/20
VA - SAN DIEGO HEALTHCARE SYSTEM
DEPARTMENT OF VETERANS AFFAIRS
3350 LA JOLLA VILLAGE DR., SAN DIEGO, CA 92161
4W NUCLEAR MEDICINE PET-CT 2, PROJECT # 664-CSI-115
ABBREVIATIONS SYMBOL LEGEND VICINITY MAP OWNER
A&E TEAM
PROJECT DESCRIPTION
PROJECT DATA
CODE REFERENCES
VA SAN DIEGO
HEALTHCARE SYSTEM
3350 LA JOLLA VILLAGE DRIVE
SAN DIEGO, CALIFORNIA 92161
ENGINEERING SERVICE
BUILDING 11, ROOM BB108 (MC138)
AOR
JOSEPH MACDONALD
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606
PHONE: 949-387-8500 EXT 157
SEOR
RAMI ELHASSAN
IDS GROUP INC.
1 PETERS CANYON ROAD, SUITE 130
IRVINE, CALIFORNIA 92606
PHONE: 949-387-8500 EXT 113
MEOR
ERIC GLATZL
IDS GROUP INC.
9636 TIERRA GRANDE STREET, SUITE 200
SAN DIEGO, CALIFORNIA 92126
PHONE: 619-768-6784 EXT 454
EEOR
ROB O'NEIL
IDS GROUP INC.
9636 TIERRA GRANDE STREET, SUITE 200
SAN DIEGO, CALIFORNIA 92126
PHONE: 619-768-6784 EXT 332
THE PROJECT INCLUDES THE DEMOLITIONAND REMODEL OF SCAN ROOM
4503 AND OTHER ASSOCIATED ROOMS, WITHIN THE NUCLEAR MEDICINE
DEPARTMENT LOCATED ON THE BUILDING 1, WEST WING, 4TH FLOOR, ON THE
EXISTING VA SAN DIEGO MEDICAL CENTER CAMPUS.
ADD ALTERNATE 1 : DEMOLITION AND REPLACEMENT OF EXISTING DOOR TO
SCAN ROOM 4505.
DEDUCT ALTERNATE 1 : ALTERNATIVE METHOD OF CONSTRUCTION OF AIR
HANDLING UNIT IN 4TH FLOOR INTERSTITIAL.
CONSTRUCTION TYPE : I - FULLY SPRINLKERED
IBC OCCUPANCY: B - BUSINESS
NFPA OCCUPANCY: AMBULATORY HEALTHCARE
PROJECT SQUARE FOOTAGE: 4025 SF
2018 INTERNATIONAL BUILDING CODE (IBC)
2019 NATIONAL ELECTRICAL CODE (NEC)
2019 AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME)
2019 AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM )
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE (IPC)
2018 INTERNATIONAL FIRE CODE (IFC)
2018 NFPA 1 - FIRE CODE
2018 NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS
2018 NFPA 14 STANDARD FOR INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
2018 NFPA 70E - STANDARD FOR ELECTRICAL SAFETY IN WORKPLACE
2018 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE
2018 NFPA 99 - HEALTH CARE FACILITIES CODE
2018 NFPA 101 - LIFE SAFETY CODE
2018 NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION
2019 NFPA 241 - STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION,
AND DEMOLITION OPERATIONS
UNDERWRITERS LABORATORY (UL)
AMERICAN SOCIETY FOR MECHANICAL ENGINEERS (ASME)
SHEET METAL AND AIR CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION (SMACNA)
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA)
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS 2015)
AFF ABOVE FINISHED FLOOR
ACST ACOUSTIC
ACT ACOUSTIC CEILING TILE
APC ACOUSTIC PANEL CEILING
AWP ACOUSTIC WALL PANEL
AWT ACOUSTIC WALL TREATMENT
ADJ ADJUSTABLE
A/C AIR CONDITIONING
AHU AIR HANDLING UNIT
ALT. ALTERNATE
AL ALUMINUM
AB ANCHOR BOLT
APPROX. APPROXIMATE
ARCH ARHICTECT
ASPH ASPHALT
ASSY ASSEMBLY
AUTO AUTOMATIC
AWN AWNING
A/V AUDIO-VISUAL
B BASEMENT
BALC BALCONY
BATH BATHROOM
BM BEAM
BR BEDROOM
BMRK BENCHMARK
BLK BLOCK
BLKG BLOCKING
BD BOARD
BKSH BOOKSHELVES
BOT BOTTOM
BRKT BRACKET
BC BROOM CLOSET
BLDG BUILDING
BLT-IN BUILT IN
BUR BUILT-UP ROOFING
BOS BOTTOM OF SLAB
CF/CI CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
CA CLEAR ANONDIZED
CAB CABINET
CPT CARPET
CSMT CASEMENT
CI CAST IRON
CB CATCH BASIN
CLG CEILING
CEM CEMENT
CL CENTER LINE
CER CERAMIC
CT CERAMIC TILE
CO CLEAN OUT
CLR CLEAR
COL COLUMN
CBP COMPOSITE BUILDING PANEL
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CJ CONTROL JOINT
COP COPPER
CG CORNER GUARD
CORR CORRIDOR
CTR COUNTER
CSMS COUNTERSUNK METAL SCREW
CSWS COUNTERSUNK WOOD SCREW
CRS COURSES
CC CUBICLE CURTAIN
CM CENTIMETER
DL DEAD LOAD
DE DUAL EGRESS
DET DETAIL
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DO DITTO
DR DOOR
DH DOUBLE HUNG
DN DOWN
DS DOWN SPOUT
D DRAIN
DWR DRAWER
DWG DRAWING
DWGS DRAWINGS
DF DRINKING FOUNTAIN
DUP DUPLICATOR
DOP DISPERSED OIL PARTICULATE
(E) EXISTING
EXIST EXISTING
ETR EXISTING TO REMAIN
EA EACH
E EAST
EQ EQUAL
EQPT EQUIPMENT
EWC ELECTRIC WATER COOLER
ELEC ELECTRICAL
ELEV ELEVATOR
EMERG EMEGENCY
EG END GUARD
ENGR ENGINEER
EQUIP EQUIPMENT
EQPT EQUIPMENT
EXP EXPANSION
EB EXPANSION BOLT
EJ EXPANSION JOINT
EXPC EXPOSED CONSTRUCTION
EXT EXTERIOR
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
FF FINISH FLOOR
FWC FABRIC WALL COVERING
FWS FABRIC WALL SYSTEM
FT FEET / FOOT
FG FINISH GRADE
FV FIELD VERIFY
FIN FINISH
FDV FIRE DEPARTMENT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHC FIRE HOSE CABINET
FP FIRE PROOFING
FRP FIBERGLASS REINFORCED PANEL
FIX FIXTURE
FLASH FLASHING
FLEX FLEXIBLE
FL FLOOR
FD FLOOR DRAIN
FS FLOOR SINK
FLUOR FLUORESCENT
FTG FOOTING
FDN FOUNDATION
FRMG FRAMING
FURN FURNACE
FTDF FIRE TREATED DOUGLAS FIR
FOF FACE OF FINISH
FOS FACE OF STUD
FLS FIRE LIFE SAFETY
GA GAGE
GALV GALVANIZED
GI GALVONIZED IRON
GEN GENERATOR
GL GLASS
GLB GLASS BLOCK
GB GRAB BAR
GR GRADE
GT GRANITE TILE
GFI GROUND FAULT CIRCUIT INTERRUPT
GUTT GUTTER
GYP GYPSUM
GYP BD GYPSUM BOARD
HR HAND RAIL
HDW HARDWIRE
HD WD HARDWOOD
HD HEAD
HVAC HEATING, VENTILATING, AND
AIR CONDITIONING
HT HEIGHT
HPAC HIGH PERMORMANCE
ARHICTECTURAL COATING
HP HIGH POINT
HC HOLLOW CORE
HM HOLLOW METAL
HORZ HORIZONTAL
HB HOSE BIBB
HOSP HOSPITAL
HC HOT AND COLD
HO HOLD-OPEN
HSS HOLLOW STEEL SECTION
IN INCH / INCHES
INFO INFORMATION
ID INSIDE DIAMETER
INS INSULATED
INSUL INSULATION
IR INTEGRAL RESILIENT BASE
INT INTERIOR
ILSM INTERIM LIFE SAFETY MEASURE
JAN JANITOR
JT JOINT
JST JOIST
KG KILOGRAM
KD KNOCK-DOWN FRAME
LL LIVE LOAD
LAB LABORATORY
LAV LAVATORY
LAM LAMINATE
LC LAUNDRY CHUTE
LT LIGHT
LTWT LIGHT WEIGHT
LB POUNDS
LIN. DIFF. LINEAR DIFFUSER
LP LOW POINT
LLV LONG LEG VERTICAL
LVT LUXURY VINYL TILE
M METER
MM MILLIMETER
MACH MACHINE
MAT MATERIAL
MH MANHOLE
MFD MANUFACTURED
MFR MANUFACTURER
MT MARBLE TILE
MK MARK
MB MARKER BOARD
MO MASONRY OPENING
MAX MAXIMUM
MIN MINIMUM
MECH MECHANICAL
MC MEDICINE CHEST
MEMB MEMBRANE
MTL METAL
MFTSM MINERAL-FILLED THERMOPLASTIC
SURFACING MATERIAL
MDF MEDIUM DENSITY FIBERBOARD
MHO MAGNETIC HOLD-OPEN
MISC MISCELLANEOUS
MOD MODIFIED
MLDG MOLDING
(N) NEW
N NORTH
N/A NOT APPLICABLE
NF NATURAL FINISH
NOM NOMINAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
NO. NUMBER
OF/OI OWNER FURNISHED /
OWNER INSTALLED
OF/CI OWNER FURNISHED /
CONTRACTOR INSTALLED
OFF OFFICE
OC ON CENTER
OA OUTSIDE AIR
OPP OPPOSITE
OH OPPOSITE HAND
ORCH ORCHESTRA
OP ORNAMENTAL PAINT
OPL ORNAMENTAL PLASTER
OD OUTSIDE DIAMETER
P PAINT
PL PLATE
PNL PANEL
PLAM PLASTIC LAMINATE
PTC PEDESTRIAN TRAFFIC COATING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PREFAB PREFABRICATED
PERF PERFORATED
PLUMB PLUMBING
QTY QUANTITY
QT QUARRY TILE
RAD RADIUS
RDWD REDWOOD
REF REFRIGERATOR
REINF REINFORCED
REBAR REINFORCING BAR
REV REVISION
RO ROUGH OPENING
RM ROOM
RA RETURN AIR
RD ROOF DRAIN
RS RESILIENT SHEET FLOORING
REQ REQUIRED
SS STAINLESS STEEL
SMS SHEET METAL SCREW
SC SOLID CORE
SCH SCHEDULE
SECT SECTION
SHTHG SHEATHING
SHT SHEET
SLV SHORT LEG VERTICAL
SPR SINGLE PLY ROOFING
SL GL DR SLIDING GLASS DOOR
SP SOLID POLYMER
SAP SOUND ABSORTIVE PANEL
SPECS SPECIFICATIONS
SQ SQUARE
SQ FT SQUARE FEET
S&V STAIN AND VARNISH
STD STANDARD
STL STEEL
STLC STEEL CHANNEL
SEJ SEISMIC JOINT
SJ STEEL JOIST
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SW SWITCH
$ SWITCH
S SOUTH
SYM SYMMETRICAL
SIM SIMILAR
TBD TO BE DETERMINED
TB TACKBOARD
TEL TELEPHONE
THK THICK
TV TELEVISION
TG TEMPERED GLASS
TEMP TEMPORARY
TLT TOILET
TOS TOP OF SLAB
TO TOP OF
TYP TYPICAL
U/S UNDERSIDE
UC UNDER CABINET
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VF/VI VENDOR FURNISHED /
VENDOR INSTALLED
VF/CI VENDOR FURNISHED /
CONTRACTOR INSTALLED
VAC VACUUM
VB VAPOR BARRIER
VERT VERTICAL
VIF VERIFY IN FIELD
VEST VESTIBULE
VCT VINYL COMPOSITION TILE
VWC VINYL WALL COVERING
W/ WITH
W/O WITHOUT
WC WASH CLOSET
WD WOOD
WT WEIGHT
WP WATER PROOF
WRB WATER RESISTANT CEMENT BOARD
WWF WELDED WIRE FRAME
WWM WELDED WIRE MESH
WF WIDE FLANGE
W WEST
WD WOOD
YD YARD
DESIGN PHASE A.O.R. S.E.O.R M.E.O.R. E.E.O.R.
35% C.D. (S.D.)
65% C.D. (D.D.)
95% C.D.
100% C.D.
DOCUMENT SUBMISSION QA / QC
Revisions: Date:
ISSUED FOR 35% C.D. 2019-02-06
ISSUED FOR 65% C.D. 2019-04-12
ISSUED FOR 65% C.D. 2020-07-10
ISSUED FOR 65% C.D. 2020-09-02
ISSUED FOR 100% C.D. 2020-10-02
ISSUED FOR CONSTRUCTION 2020-11-06
ISSUED FOR CONSTRUCTION 2020-12-04
C urve len =Tangent =R adius =D elta =Lot =
DESIGN PHASE A.O.R. S.E.O.R M.E.O.R. E.E.O.R.
35% C.D. (S.D.)
65% C.D. (D.D.)
95% C.D.
100% C.D.
C urve len =Tangent =R adius =D elta =Lot =
T A
R
NJUNE 2021
C-34131
T A
R
NJUNE 2021
C-34131
C urve len =Tangent =R adius =D elta =Lot =
L
IC
ENSED ARCH IT
E C
T
S T
A T
E
OF CA L I FO
R N
I AJUNE 2021
MACDONALD
JOSEPH H.
RENEWAL DATE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:5
P
M
GI-002
DRAWING LIST AND GENERAL NOTES
11/06/20
ARCHITECTURAL
AD-104 LEVEL 4 - DEMO FLOOR PLAN
AD-204 LEVEL 4 - DEMO CEILING PLAN
AE-101 LEVEL 4 & 6 - OVERALL EXISTING PLANS
AE-101I LEVEL 3 & 4 - OVERALL INTERSTITIAL EXISTING PLANS
AE-104 LEVEL 4 - FLOOR PLAN
AE-104A LEVEL 4 & 6 - FLOOR PLANS
AE-104I LEVEL 4 - INTERSTITIAL REMODEL
AE-204 LEVEL 4 - REFLECTED CEILING PLAN
AE-210A EQUIPMENT SCHEDULE
AE-300 SECTIONS AND INTERIOR ELEVATIONS
AE-400 LEVEL 4 - FINISH PLAN
AE-401 FINISH LIST
AE-601 DOOR AND WINDOW SCHEDULES
AE-603 WALL DETAILS
AE-604 WALL DETAILS
AE-605 CEILING DETAILS
AE-606 MISCELLANEOUS DETAILS
AE-607 LUMINOUS WINDOW AND WALL PANEL
AE-608 LEAD LINING DETAILS
AE-609 LEAD LINING DETAILS
MECHANICAL
MH-001 MECHANICAL GENERAL NOTES, LEGEND & ABBREVIATIONS
MH-002 MECHANICAL GENERAL NOTES, LEGENDS
MH-003 MECHANICAL SCHEDULES
MH-100 LEVEL 4 - HVAC ZONING
MH-101 LEVEL 4 - MECHANICAL DEMO PLAN
MH-102 LEVEL 4 - MECHANICAL REMODEL
MH-102I-A LEVEL 4 INTERSTITIAL - MECHANICAL REMODEL
MH-102I-B LEVEL 4 INTERSTITIAL - MECHANICAL REMODEL
MH-103 MECHANICAL PLAN REMODEL
MH-104 LEVEL 4 INTERSTIAL - MECHANICAL PIPING
MH-105 AIRHANDLING UNIT 420 - PATH OF TRAVEL
MH-201 MECHANICAL SECTION
MH-501 SIEMENS EQUIPMENT DETAILS
MH-502 MECHANICAL DETAILS
MH-503 MECHANICAL DETAILS
MH-504 MECHANICAL DETAILS
MH-505 MECHANICAL DETAILS
MH-601 CONTROL DIAGRAMS
MH-602 CONTROL DIAGRAMS
PLUMBING
PL-001 GENERAL NOTES, LEGEND, SCHEDULES & ABBREVIATIONS
PL-101 FOURTH FLOOOR DEMO PLAN - PLUMBING
PL-102 FOURTH FLOOR PLAN - PLUMBING
PL-102.1 LEVEL 4 INTERSTITIAL - PLUMBING REMODEL
PL-301 LEVEL 4 INTERSTITIAL - ENLARGED REMODEL B
PL-501 PLUMBING DETAILS
ELECTRICAL
EP-001 ELECTRICAL GEN NOTES, LEGEND & ABBREVIATIONS
EP-002 LIGHTING FIXTURES SCHEDULE & CALCULATIONS
EP-003 SINGLE LINE DIAGRAM
EP-004 ELECTRICAL PANEL SCHEDULES
EP-005 VOLTAGE DROP CALCULATIONS & LOAD SUMMARY
EP-100 ELECTRICAL 4TH FLOOR - INTERSTITIAL
EP-101 ELECTRICAL 4TH INTERSTITIAL - ENLARGED PLANS
EP-102 ELECTRICAL 4TH FLOOR - AREA OF WORK DEMOLITION
EP-103 4 TH FLOOR - AREA OF WORK REMODEL - LIGHTING
EP-104 4 TH FLOOR - AREA OF WORK REMODEL - POWER
EP-105 ELECTRICAL ENLARGED PLANS
EP-106 ELECTRICAL ENLARGED PLANS
EP-107 4TH FLOOR-AREA OF WORK REMODEL-SIGNAL
EP-300 ELECTRICAL LIGHTING CONTROL
EP-301 ELECTRICAL LIGHTING CONTROL SINGLE LINE DIAGRAM
EP-601 ELECTRICAL DETAILS
DRAWINGS NO. DRAWING NAME
GENERAL
GI-001 COVER SHEET
GI-002 DRAWING LIST AND GENERAL NOTES
GI-003 ADA DETAILS & ADA CODE COMPLIANCE NOTES
GI-005 EXISTING SITE PLAN (FOR REFERENCE)
GI-100 ACCESSIBILITY PATH OF TRAVEL
GI-101 EGRESS PLAN
HA-001 4TH FLOOR - HAZARDOUS MATERIAL ABATEMENT
HA-001.1 4TH FLOOR INTERSTITIAL - HAZARDOUS MATERIAL ABATEMENT
HA-002 PATH TO EXIT - HAZARDOUS MATERIAL ABATEMENT
HA-003 INFECTION CONTROL PROTOCOLS AND CONSTRUCTION PHASING
DRAWINGS LIST
STRUCTURAL
SF1 GENERAL NOTES
SF2 GENERAL NOTES
SF3 4TH FLOOR FRAMING PLANS, EQUIPMENT
SCHEDULE & DETAILS
SF4 LEVEL 4 PARTIAL STRUCTURAL FRAMING PLAN
SF5 SECTIONS AND DETAILS
SF6 SECTIONS AND DETAILS
SF7 SECTIONS AND DETAILS
GENERAL NOTES CONSTRUCTION NOTES
1. CONTRACTOR TO PROVIDE COLOR COPIES OF MARKED-UP RECORD SET PLANS TO OWNER UPON
PROJECT COMPLETION TO BE USED AS AE-BUILTS.
2. IF ANY PART OF EQUIPMENT FURNISHED UNDER THIS CONTRACT REQUIRES SPECIAL TOOLS FOR MAINTENANCE, ADJUSTMENT, SETTINGS OR DISASSEMBLY/REASSEMBLY, THESE TOOLS SHALL BE
FURNISHED WITH EQUIPMENT AS A STANDARD ACCESSORY.
3. ALL DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY FIELD CONDITIONS PRIOR TO START
OF CONSTRUCTION.
4. CONTRACTOR TO PATCH AND REPAIR ALL WALLS, FLOORS, CEILINGS AND OTHER ITEMS DAMAGED
DURING CONSTRUCTION TO MATCH EXISTING/INTENDED FUNCTIONS AND CONDITIONS.
5. CONTRACTOR TO LOCATE ALL "VA RETAINED" MATERIAL TO THE EAST LOADING DOCK IN THE
BASEMENT; VETERAN AFFAIRS PROJECT MANAGER WILL COORDINATE LOCATION OF MATERIAL.
6. ALL MATERIAL NOT IDENTIFIED AS "VA RETAINED" IS TO BE REMOVED FROM THE PREMISES BY
CONTRACTOR.
7. REMOVE AND RELOCATE OR REROUTE ANY UTILITIES WHICH PRESENT AN OBSTRUCTION TO
GENERAL CONSTRUCTION FOR THIS PROJECT.
8. ALL UTILITIES SHALL BE ROUTED TO CLEAR OBSTRUCTIONS, MAINTAINING CLEAR ACCESS FROM ANY
CATWALKS OR PATHWAYS AT ALL TIMES.
9. PROVIDE SEISMIC SUPPORT AND BRACING TO ALL UTILITIES AND GENERAL CONSTRUCTION IN THIS
PROJECT.
10. UTILITIES SHALL BE RUN CONCEALED EXCEPT IN UNFINISHED AREAS
11. ALL PENETRATIONS THROUGH FLOORS AND SMOKE BARRIERS SHALL BE TIGHTLY SEALED USING UL APPROVED SYSTEM AS REQUIRED BY SPECIFICATION 07 84 00 FIRESTOPPING. ANY EXISTING
CORE CUTS ARE TO BE FILLED WITH SIMILAR MATERIAL.
12. "WARNING" : ASBESTOS PRESENT IN INTERSTITIAL AREAS IN FIRE PROOFING ON STRUCTURAL
STEEL, OVERSPRAY ON 4-INCH I-BEAMS AND CONCRETE DECKS. CONTRACTOR TO WEAR
RESPIRATOR AND PROTECTIVE COVERALLS IN ACCORDANCE WITH LOCAL, STATE & FEDERAL
REGULATIONS.
13. WARNING" : ASBESTOS PRESENT IN VINYL COMPOSITION FLOOR TILE & MASTIC. CONTRACTOR TO
DISPOSE OF ALL HAZARDOUS WASTE IN ACCORDANCE WITH LOCAL, STATE & FEDERAL
REGULATIONS. CONTRACTOR TO WEAR RESPIRATOR & PROTECTIVE COVERALLS IN ACCORDANCE
WITH LOCAL, STATE & FEDERAL REGULATIONS.
14. CORRIDOR AREAS ARE TO MAINTAIN FIRE PROTECTION BARRIER MATCHING EXISTING CORRIDOR
WALL CONSTRUCTION.
15. CONTRACTOR TO PROVIDE TEMPORARY WALL SEPARATING PUBLIC FROM PROJECT AREA(S).
BARRIER TO BE AIR TIGHT FLOOR TO CEILING WITH SECURED OPENING.
16. (E) HAZARDOUS MATERIALS NOT NOTED ON PLANS BUT DISCOVERED IN SCOPE OF WORK AREA WILL
NEED TO BE REMOVED. CONTRACTOR TO COORDINATE WITH VETERANS AFFAIRS PROJECT
MANAGER FOR REMOVAL OF HAZ. MAT. ITEMS.
17. "WARNING" : RADIOACTIVE EQUIPMENT IS USED WITHIN THE VICINITY OF THIS AREA. CONTRACTOR
TO COORDINATE WITH HOSPITAL AND VETERANS AFFAIRS PROJECT MANAGER TO PREVENT
EXPOSURE TO RADIATION.
DEMOLITION NOTES
1. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION OF THEIR WORK WITH THE WORK OF OTHERS. SUBCONTRACTORS SHALL VERIFY THAT ANY WORK RELATED TO THEM, WHICH MUST BE PROVIDED BY OTHERS, HAS BEEN COMPLETED AND IS ADEQUATE PRIOR TO
COMMENCING THEIR WORK.
2. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS WITH THE CONTRACT DOCUMENTS BEFORE COMMENCING ACTIVITIES.
THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS INSOFAR AS NECESSARY TO INSTALL THE WORK PROPERLY AND RELATIVE TO THE SURROUNDING CONSTRUCTION. PRIOR TO SUBMISSION OF BIDS, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY CONFLICTS, ERRORS OR OMISSIONS. NO ADDITIONAL CHARGES BY CONTRACTOR SHALL BE ALLOWED FOR DISCREPANCIES BETWEEN EXISTING CONDITIONS AND NEW
CONSTRUCTION THAT COULD HAVE BEEN IDENTIFIED DURING EXAMINATION.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER LOCATION AND SIZE OF OPENINGS FOR ALL TRADES, AND SHALL COORDINATE ALL
CONSTRUCTION AS INDICATED BY THE CONTRACT DOCUMENTS, INCLUDING SHOP DRAWINGS.
4. CONTRACTOR SHALL ARRANGE FOR, IN ADVANCE WITH THE VETERANS AFFAIRS PROJECT MANAGER, CONSTRUCTION STORAGE AND STAGING AREAS NECESSARY TO COMPLETE THE WORK. ALL STORAGE AND STAGING AREAS SHALL BE RETURNED TO THE OWNER IN LIKE ORIGINAL CONDITION.
5. CONTRACTOR SHALL MAINTAIN A CLEAN WORK PLACE. DUST POLLUTION AND PREVENTION OF DUST CONTAMINATION OF NON-WORK SPACES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR ON AN ON GOING, DAILY BASIS. THE CONTRACTOR SHALL DEVELOP A SCHEDULE OF CONSTRUCTION WHICH INCLUDES THE NECESSARY ACTIONS TO MAINTAIN THE OPERATION OF THE ADJACENT FUNCTIONS IN ACCORDANCE WITH NFPA 241 (INCLUDING THOSE ONE FLOOR
ABOVE OR BELOW DURING THE CONSTRUCTION PROCESS).
6. THE ARCHITECT/ENGINEER SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.
7. IF AT ANY TIME SHOULD ANY CONDITIONS ARISE WHEREIN THE INTENT OF THE DRAWINGS IS IN DOUBT OR WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND FIELD CONDITIONS, THE ARCHITECT / ENGINEER AND VA PM SHALL BE NOTIFIED IMMEDIATELY FOR WRITTEN CLARIFICATION.
8. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. SAFETY OF ALL PARTIES PRESENT ON THE JOB SITE IS SOLELY THE CONTRACTORS RESPONSIBILITY, THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONJUNCTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE
OWNER OR THE ARCHITECT/ENGINEER.
9. THE CONTRACTOR SHALL HAVE FULL RESPONSIBILITY AND CHARGE OF AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, AND FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK OR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS.
10. STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL CONTRACTORS SHALL REVIEW ARCHITECTURAL AND OTHER TRADES DRAWINGS FOR
COORDINATION.
11. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CODES, ORDINANCES, AND LAWS REFERENCED HEREIN. ANY DEVIATION FROM, OR DISCREPANCY WITH, THESE CODES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK, ORDERING MATERIALS OR
ESTABLISHING THE CONSTRUCTION SCHEDULE.
12. ALL DRAWINGS, THOUGH NOTED TO SCALE, ARE FOR ILLUSTRATION ONLY. THE CONTRACTOR SHALL NOT SCALE DRAWINGS. ALL DIMENSIONS TO BE TAKEN
FROM FACE OF FINISH UNLESS NOTED OTHERWISE.
13. CONTRACTOR SHALL HAVE A DESIGNATED PROJECT REPRESENTATIVE ON SITE AT ALL TIMES WHILE WORK IS BEING PERFORMED.
14. CONTRACTOR SHALL MAINTAIN AN APPROVED SET OF PLANS ON THE JOB SITE DURING CONSTRUCTION.
15. CONTRACTOR SHALL PROVIDE AN APPROPRIATE NUMBER OF PORTABLE FIRE EXTINGUISHERS FOR PROTECTION DURING CONSTRUCTION, PER NFPA 241 .
16. CONTRACTOR SHALL COORDINATE ALL WORK INSIDE AND OUTSIDE LIMITS OF WORK AREA.
17. CONTRACTOR ROUTE OF TRAVEL THROUGHOUT HOSPITAL SITE TO BE APPROVED BY VETERANS AFFAIRS PROJECT MANAGER. IF ROUTE OF TRAVEL OR PERFORMANCE OF WORK AFFECTS ANY REQUIRED EXITWAYS, CONTRACTOR SHALL NEED TO ATTAIN APPROVAL BY VETERANS AFFAIRS PROJECT MANAGER
PRIOR TO CONSTRUCTION.
18. THE CONTRACTOR SHALL COORDINATE THE CONSTRUCTION WITH THE VETERANS AFFAIRS PROJECT MANAGER, SO THE DISRUPTION OF THE HOSPITAL OPERATIONS WILL BE MINIMIZED. WHERE APPLICABLE AND APPROVED BY A VA REPRESENATIVE- WORK MAY BE PREFORMED AFTER HOURS TO PROVIDE FOR
UNINTERUPTED USE OF HOSPITAL OPERATIONS.
19. CONTRACTOR SHALL WORK AROUND OWNER'S AREAS WHICH NEED TO BE MAINTAINED IN FULL OPERATING CONDITION AT ALL TIMES.
20. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL SUBSTRUCTURES BEFORE COMMENCING WORK, WHETHER SHOWN HEREIN OR NOT AND TO PROTECT THEM FROM DAMAGE. THE EXPENSE OF REPAIR OR REPLACEMENT OF SAID SUBSTRUCTURES SHALL BE BORNE BY THE CONTRACTOR.
21. ALL UTILITIES SHOWN ON THESE DOCUMENTS ARE A RESULT OF A SITE REVIEW AND A REVIEW OF THE AVAILABLE RECORDS SUPPLIED BY THE OWNER.
CONTRACTOR TO OBTAIN TRUE VERTICAL AND HORIZONTAL DIMENSIONS OF UTILITIES BEFORE BEGINNING CONSTRUCTION AND SHALL BE RESPONSIBLE FOR
ANY DAMAGE THERETO, OR FEES RESULTING FROM DAMAGE THERETO.
22. ANY UTILITY SHUTDOWNS REQUIRED SHALL BE REVIEWED WITH THE VETERANS AFFAIRS PROJECT MANAGER, AND SHALL NOTIFY AT MINIMUM 30 DAYS PRIOR
TO PROPOSED SHUTDOWN.
23. PENETRATIONS THROUGH RATED WALLS, FLOORS AND ROOFS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC OF FIRESTOPS: ASTM-E-814. SEE DETAIL 16/AE-604.
24. PENETRATIONS INTO SOUND RATED PARTITIONS OR CEILING ASSEMBLIES SHALL BE SEALED WITH AN APPROVED PERMANENT RESILIENT SEALANT.
ELECTRICAL DEVICES, RECESSED CABINETS, ETC. SHALL BE SEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN INTEGRITY OF THE ACOUSTICAL ASSEMBLY AS SPECIFIED IN DIVISION 7 OF THE SPECIFICATIONS AFTER PERMANENT RESILIANT SEALANT.
25. THE CONTRACTOR SHALL COMPLY WITH DEPARTMENT OF VETERANS AFFAIR HOSPITAL POLICIES PERTAINING TO CONSTRUCTION / RENOVATION.
26. NEW PIPES, DUCTS AND CONDUITS SHALL BE SUPPORTED AND BRACED ACCORDING TO CURRENT DODE: REFER TO 2018 IBC CHAPTER 16 OR 2016 EDITION OF
ASCE 7.
27. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION
TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS.
28. CUTTING OF HOLES THROUGH CONCRETE SHALL BE BY DIAMOND CORE DRILL OR PNEUMATIC HAMMER. IMPACT ELECTRIC MANUAL HAMMER TYPE DRILLS
WILL NOT BE ALLOWED.
1. ALL ITEMS ON THESE DRAWING INDICATED WITH DASHED LINES ARE EXISTING TO BE REMOVED AS INSTRUCTED IN THE DEMOLITION KEYNOTES. ALL OTHER ITEMS ARE EXISTING TO REMAIN UNLESS
NOTED OTHERWISE.
2. COORDINATE ALL DEMOLITION WORK INDICATED ON THESE DRAWING, INCLUDING THE REMOVAL OF ALL LOOSE, UNUSED OR ABANDONED WIRING, CONDUIT, PIPING, DUCTWORK, SUPPORT WIRES AND
ANCHORS WITH THE MECHANICAL, ELECTRICAL AND PLUMBING DEMOLITION DRAWINGS.
3. USE EXTREME CARE TO AVOID DAMAGING ANY AREA ADJACENT TO THE DEMOLITION WHICH IS NOT
PART OF THE WORK. ANY DAMAGE TO AREAS NOT PART OF THE WORK SHALL BE PATCHED,
REPAIRED OR REPLACED BY THE CONTRACTOR TO THE SATISFACTION OF THE OWNER, AT NO COST
TO THE OWNER.
4. KEYNOTES SHALL APPLY TYPICALLY TO ALL LIKE CONDITIONS, UNLESS NOTED OTHERWISE.
5. COORDINATE ALL WORK REQUIRED BY MECHANICAL, PLUMBING AND ELECTRICAL
SUBCONTRACTORS. PATCH AND REPAIR WHERE ITEMS ARE REMOVED AND RESTORE TO MATCH
ADJACENT SURFACES. PROVIDE DEMO WORK AS REQUIRED WHERE NEW ITEMS ARE TO BE
INSTALLED IN EXISTING CONDITIONS, AS REQUIRED TO COORDINATE THE WORK.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, MAINTAINING, RELOCATION AND/OR
REMOVING EXISTING UTILITIES.
7. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND IDENTIFY ALL BEARING
STRUCTURAL ELEMENTS, MECHANICAL, PLUMBING, ELECTRICAL AND ALL OTHER EXISTING SYSTEMS
AND MAKE NECESSARY PROVISIONS TO MAINTAIN THE INTEGRITY OF SAID SYSTEMS PRIOR TO
COMMENCEMENT OF DEMOLITION.
8. WHERE GYPSUM BOARD IS REMOVED FROM STUDS, NEW GYPSUM BOARD MUST BE REPLACED
WITHIN ONE EIGHT HOUR SHIFT, OR CONTRACTOR SHALL PROVIDE APPROVED FIRE-WATCH.
9. INFECTION CONTROL BARRIERS MUST BE COORDINATED BETWEEN CONTRACTOR AND OWNER., AND
ARE THE RESPONSIBILITY OF THE CONTRACTOR.
10. IN ALL AREAS TO RECEIVE NEW CEILING, PER REFLECTED CEILING PLANS, REMOVE EXISTING
CEILING INCLUDING ALL SUPPORT CHANNELS, WIRES, ANCHORS AND CEILING MOUNTED
ACCESSORIES. REROUTE, RECIRCUIT, TERMINATE OR ABANDON ALL EXISTING SERVICES.
11. IN ALL AREAS OF WORK, CAREFULLY REMOVE ANY EXISTING WALL MOUNTED EQUIPMENT AND
ACCESSORIES SO AS NOT TO DAMAGE. TEMPORARY RELOCATION OF EQUIPMENTT TO BE
COORDINATED WITH VETERANS AFFAIRS PROJECT MANAGER.
12. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN DEMOLISHING ALL FLOORS, WALLS, CEILINGS ETC. HAND DEMOLITION OF THE SPACE MAY BE REQUIRED TO AVOID DAMAGE TO VITAL UTILITY FEATURES RUNNING THROUGH THE SCOPE OF WORK INTO ADJACENT SPACES. THERE MAY BE CONCEALED PIPING, ELECTRICAL, MEDICAL GAS, DUCTWORK ETC. IN THE WALLS, BELOW THE FLOORS AND ABOVE THE CEILINGS THROUGHOUT. ALL SUCH FEATURES SHALL REMAIN PROTECTED-
IN-PLACE. PORTIONS OF EXISTING CONSTRUCTION TO BE REMOVED AS REQUIRED FOR NEW
CONSTRUCTION. ENSURE SYSTEMS SERVING OTHER AREAS OUTSIDE THE RENOVATION SCOPE
REMAIN UNAFFECTED AND OPERATIONAL THROUGHOUT DEMOLITION AND CONSTRUCTION.
LIFE SAFETY NOTES
1. ENSURE EXITS PROVIDE FREE AND UNOBSTRUCTED EGRESS. PERSONNEL RECEIVE TRAINING IF ALTERNATIVE EXITS MUST BE DESIGNATED. BUILDING/AREAS UNDER CONSTRUCTION MUST MAINTAIN ESCAPE FACILITIES FOR CONSTRUCTION WORKERS AT ALL TIMES. MEANS OF EGRESS IN CONSTRUCTION AREAS ARE
INSPECTED DAILY.
2. FIRE ALARM, DETECTION & SUPPRESSION SYSTEMS ARE NOT TO BE IMPAIRED. A TEMPORARY BUT EQUIVALENT SYSTEM SHALL BE PROVIDED WHEN ANY FIRE
SYSTEM IS IMPAIRED. TEMPORARY SYSTEMS MUST BE INSPECTED AND TESTED MONTHLY.
3. PROVIDE ADDITIONAL FIRE-FIGHTING EQUIPMENT AND USE TRAINIED PERSONNEL. CONTRACTOR TO TRAIN STAFF ON LOCATION OF AFS SHUT OFF VALVES
SERVING PROJECT AREA.
4. SMOKING SHALL BE PROHIBITED AT ALL TIMES, IN OR ADJACENT TO ALL CONSTRUCTION AREAS. NO SMOKING ON STATION.
5. DEVELOP AND ENFORCE STORAGE, HOUSEKEEPING, AND DEBRIS REMOVAL PRACTICES THAT REDUCE THE FLAMMABLE AND COMBUSTIBLE FIRE LOAD OF THE BUILDING TO THE LOWEST LEVEL NECESSARY FOR DAILY OPERATIONS. COMPLY WITH NFPA 241.
6. INCREASE SURVEILLANCE OF BUILDINGS, AND EQUIPMENT WITH SPECIAL ATTENTION TO EXCAVATIONS, CONSTRUCTION AREAS, CONSTRUCTION STORAGE, AND FIELD OFFICES.
7. PROVIDE TEMPORARY DIRECTIONAL SIGNAGE APPROVED BY VETERANS AFFAIRS PROJECT MANAGER.
FIRE PROTECTION
FP-001 FIRE PROTECTION NOTES, LEGEND AND ABBREVIATIONS
FP-204 LEVEL 4 - FIRE PROTECTION FLOOR PLAN
SIEMENS REFERENCE DRAWINGS
DRAWING NO. DRAWING NAME
QH-101 ARCHITECTURAL EQUIPMENT PLAN, NOTES AND LEGEND
QH-102 SAFETY/SERVICE CLEARANCE PLAN, NOTES AND DETAILS
QH-103 STRUCTURAL FLOOR PLAN, NOTES AND DETAILS
QH-104 STRUCTURAL CEILING PLAN AND DETAILS
QH-105 STRUCTURAL NOTES
QH-106 MECHANICAL PLAN AND DETAILS
QH-107 MECHANICAL DETAILS
QH-108 ELECTRICAL RACEWAY PLAN, LEGEND AND NOTES
QH-109 ELECTRICAL DIMENSION PLAN AND LEGEND
QH-110 POWER REQUIREMENTS, SCHEDULE, DIAGRAM, NOTES AND DETAILS
Revisions: Date:
ISSUED FOR 65% C.D. 2020-07-10
ISSUED FOR 65% C.D. 2020-09-02
ISSUED FOR 100% C.D. 2020-10-02
ISSUED FOR CONSTRUCTION 2020-11-06
ISSUED FOR CONSTRUCTION 2020-12-04
L
IC
ENSED ARCH IT
E C
T
S T
A T
E
OF CA L I FO
R N
I AJUNE 2021
MACDONALD
JOSEPH H.
ABAAS FIGURE 403.5.1
CLEAR WIDTH FOR AN
ACCESSIBLE ROUTE
ABAAS FIGURE 304.3.2
T-SHAPED TURNING SPACE
M A
X
M
IN
M A
X
M
IN
12"
MIN
36" MIN 12"
MIN
M
IN
" M
IN
ABAAS FIGURE 305.5
POSITION OF CLEAR FLOOR
32 MIN
36 MIN
32" MIN
36" MIN
M
IN
36" MIN
X
4"
ABAAS FIGURE 305.7.1
MANUEVERING CLEARANCE IN AN
ALCOVE, FORWARD APPROACH
60" MIN
X
ABAAS FIGURE 305.7.1
MANUEVERING CLEARANCE IN AN
ALCOVE, PARALLEL APPROACH
" M
IN
48" MIN
30" MIN
60"
ABAAS 304.3.1
CIRCULAR SPACE.
THE TURNING SPACE
SHALL BE A SPACE
OF 60 INCHES
DIAMETER MINIMUM
5' - 6"
CEILING LINE (WHERE OCCURS)
BUTT HINGE
DOOR LEAF
LIGHT SWITCH. (DASHED LINE
INDICATES LARGER PLATE AT
GANGED SWITCHES)
FINISH FLOOR
DOOR FRAME
HARDWARE SET
ELECTRICAL OUTLET
WALL TELEPHONE/DATA OUTLET
NOTE:
TOP OF SWITCH TO BE AT 48" A.F.F. MAXIMUM. CENTER ALL OTHER DEVICES ON CENTERLINE OF LIGHT SWITCHES. TOP OF SWITCH TO BE AT 40" A.F.F. MAXIMUM WHERE SWITCH IS LOCATED ABOVE A COUNTER.
INSTALL ELECTRICAL AND TELEPHONE WALL OUTLETS AND SWITCH PLATES TO NEAREST STUD LOCATION
AS SCALED ON PLAN, UNLESS DIMENSIONED OTHERWISE.
THERMOSTAT
EVACUATION SIGNAGE
PULLSTATION60
" M
A X
TO
P
O F
S W
IT
C
H P
LA
TE
M
A X
" M
IN
6"
2 3/4"
5" E
Q
E Q
E
Q
CL
CL
CL
CARD READER
NOTE: 4'-0" TO
HIGHEST PORTION
OF ANY OPERABLE
EQUIPMENT (TYP)
CL
(O R
M A
TC
H
B
LD
G S
TD
" M
IN
.-4
4" M
A X
4'
0"
COAT HOOK (ON BACK OF DOOR)
8'
0"
6'
8"
CL
CL
6"
" M
A X
EXIT
SIGN
FIRE
STROBE
FIRE EXTINGUISHER
CABINETDOOR
HANDLE
EDGE OF WALL (WHERE OCCURS)
CL
" M
IN
CL
ELECTRICAL OUTLET
WALL TELEPHONE/DATA OUTLET
8'
6"
" M
A X
CL
LIGHT SWITCHES
(GANG WHERE
POSSIBLE)
SECONDARY
OVERRIDES
GREEN LIGHT
INDICATOR
CL
ABAAS 308.2.1
UNOBSTRUCTED FORWARD REACH
AREA OF
REFUGE
" M
IN
18" MIN
ABAAS 309 OPERABLE PARTS
A B
O V
E C
O U
N
TE
R
X
X
MAX
4"
ABAAS FIGURE 307.2
LIMITS OF PROTRUDING OBJECTS
(F) HINGE APPROACH, PUSH SIDE
" M
IN
36" MIN60
" M
IN
(D) LATCH APPROACH, PULL
SIDE
(A) FRONT APPROACH, PULL SIDE
OF EXT. DOORS
24" MIN
AT EXT. SIDE
" M
IN
MIN
18"
MIN
(C) FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
" M
IN
12"
(B) FRONT APPROACH, PUSH SIDE
" M
IN
(G) HINGE APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
" M
IN
MIN
(H) LATCH APPROACH, PULL SIDE
MIN
24"
" M
IN
MIN
24"
(K) LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH CLOSER
ABAAS FIGURE 404.2.4.1
MANUEVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
(E) LATCH APPROACH, PULL SIDE
42" MIN
" M
IN
" M
IN
" M
IN
MIN
24"
(J) LATCH APPROACH, PUSH SIDE,
(I) LATCH APPROACH, PULL SIDE
DOOR PROVIDED WITH CLOSER
MIN
24"
" M
IN
36" MIN 36 MINX < 48
180 ° TURN
(EXCEPTION)
180° TURN
" M
IN
42" MIN 42" MINX < 48
" M
IN
ABAAS FIGURE 403.5.2
CLEAR WIDTH AT TURN
(A) FRONT APPROACH
" M
IN
(D) STOP OR LATCH APPROACH
MIN
24"
(C) POCKET OR HINGE APPROACH
" M
IN
MIN
22"
" M
IN
(B) SIDE APPROACH
ABAAS FIGURE 404.2.4.2
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES AND FOLDING DOORS
1/ 4"
M A
X
ABAAS FIGURE 303.3
BEVELED CHANGE IN LEVEL
ABAAS FIGURE 303.2
VERTICAL CHANGE IN LEVEL
1/ 4" .
1/ 4" . 1/
2" .
TO
EXIT
EXIT
EXIT
EXIT
ROUTE
STAIR
DOWN
" T
Y P
IC
A
L
CL
1/8"
THK
1/8"
THK
(3")
(3
(1
(3 /8
(7
/8
(3")
(3")(3") (5
/8
(3
(1
(3 /8
(7
/8
(5 /8
(3
(1
(3 /8
(7
/8
(5 /8
(1
(7 /8
(5
/8
(4
(7 /8
(3
/8
ALL LOBBY AREAS WITH DOOR
LEADING INTO RATED CORRIDOR
TO BUILDING EXIT
AT EXITS LEADING TO
EXTERIOR OF BUILDING
AT ROOM / AREA EXITS LEADING
INTO RATED CORRIDORS TO
BUILDING EXITS
AT CORRIDOR SIDE OF EXIT
STAIRS ON ALL UPPER FLOORS
SIGNS SHALL COMPLY WITH SECTION 11B-703. WHERE BOTH VISUAL AND TACTILE CHARACTERS
ARE REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO
SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE
PROVIDED.
RAISED CHARACTERS SHALL COMPLY WITH SECTION 11B-703.2 AND SHALL BE DUPLICATED IN
BRAILLE COMPLYING WITH SECTION 11B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN
ACCORDANCE WITH SECTION 11B-703.4. RAISED CHARACTERS SHALL BE 1/32 INCH (0.8 MM)
MINIMUM ABOVE THEIR BACKGROUND. CHARACTERS SHALL BE UPPERCASE. CHARACTERS
SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY
DECORATIVE, OR OF OTHER UNUSUAL FORMS. CHARACTERS SHALL BE SELECTED FROM FONTS
WHERE THE WIDTH OF THE UPPERCASE LETTER “O” IS 60 PERCENT MINIMUM AND 110 PERCENT
MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER “I”. CHARACTER HEIGHT MEASURED
VERTICALLY FROM THE BASELINE OF THECHARACTER SHALL BE 5/8 INCH (15.9 MM) MINIMUM AND
2 INCHES (51 MM) MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER “I”. STROKE
THICKNESS OF THE UPPERCASE LETTER “I” SHALL BE 15 PERCENT MAXIMUM OF THE HEIGHT OF
THE CHARACTER.
BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE
11B-703.3.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED
BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS
OF THE ALPHABET, INITIALS, AND ACRONYMS. BRAILLE SHALL BE POSITIONED BELOW THE
CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-
LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE SHALL BE
SEPARATED 3/8 INCH (9.5 MM) MINIMUM AND 1/2 INCH (12.7 MM) MAXIMUM FROM ANY OTHER
TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUM FROM RAISED BORDERS AND
DECORATIVE ELEMENTS.
TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES (1219 MM) MINIMUM ABOVE THE
FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE
CELLS AND 60 INCHES (1524 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND
SURFACE,MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS.
WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE
THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN
IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO
THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE
OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON
THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED
SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (457 MM) MINIMUM BY 18 INCHES (457 MM)
MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY
DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE
PROVIDED, SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL BE LOCATED AT THE
ENTRANCE TO, AND OUTSIDE OF THE ROOM OR SPACE. WHERE PROVIDED, SIGNS IDENTIFYING
EXITS SHALL BE LOCATED AT THE EXIT DOOR WHEN APPROACHED IN THE DIRECTION OF
EGRESS TRAVEL.
FIN.
FLOOR
2018 IBC 1013.4 AND ICC A117.1
4'
0"
DOOR
OPENER
RTP PALLETSOAP
DISPENSER
TOWEL
DISPENSER
SHARP
CONTAINER
EPOTELVALVE
BOX
NURSE
CALL
MEDICAL
GAS ALARM
THERMOSTAT TEMPERATURE
SWITCH
1/4" = 1'-0"ACCESSIBLE ROUTES 3
1/2" = 1'-0"DEVICE MOUNTING HEIGHTS 1
1/2" = 1'-0"LIMITS OF PROTRUDING OBJECTS 8 1/4" = 1'-0"MANEUVERING CLEARANCES 2
1/4" = 1'-0"CLEAR WIDTH OF AN ACCESSIBLE ROUTE 6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:5
P
M
GI-003
ADA DETAILS & ADA CODE COMPLIANCE
NOTES
11/06/20
1/4" = 1'-0"MANEUVERING CLEARANCES 7
1/4" = 1'-0"CHANGES IN FLOOR LEVEL 5
3" = 1'-0"TACTILE EXIT SIGNAGE 9
Revisions: Date:
ISSUED FOR 65% C.D. 2020-07-10
ISSUED FOR 65% C.D. 2020-09-02
ISSUED FOR 100% C.D. 2020-10-02
ISSUED FOR CONSTRUCTION 2020-11-06
ISSUED FOR CONSTRUCTION 2020-12-04
1/2" = 1'-0"MOUNTING HEIGHTS 4
L
IC
ENSED ARCH IT
E C
T
S T
A T
E
OF CA L I FO
R N
I AJUNE 2021
MACDONALD
JOSEPH H.
P ar ki ng
L ot
E
VI
LL
A
LA
J O
LL
A
D R
C urve len =Tangent =R adius =D elta =Lot =
#4#3
#7#8
#2
#1
Pedestrian Bridge
Length = Bearing =
Length =B earing =
#5
#6
18 9
Gilman Drive
North Road 14 Parking
Lot - P1 17 19
E as t R oa d
Parking Lot - H
Parking Lot
Parking Lot
Parking Lot
3 5
South Road
VI
LL
A
LA
J O
LL
A
D R
LA JOLLA VILLAGE DR
LA JOLLA VILLAGE DR
S A
N D
IE
G
O F
W Y
S A
N D
IE
G
O F
W Y
PARKING
GARAGE 1
STRUCTURE
PARKING
GARAGE 2
STRUCTURE
28 31
LEGEND
HATCH INDICTATES AREA NOT
INCLUDED IN SCOPE OF WORK
4-5" X 4-5" INTERNATIONAL SYMBOL OF
ACCESSIBILITY
WHEEL STOP
ACCESSIBILITY SIGN PER LOCAL CODES
LOADING AND LANDING ACCESS AISLE /
WALKING AISLE
CURB DETAIL
PATH OF TRAVEL
1. INPATIENT/OUTPATIENT AMBULATORY SERVICES
2. BOILER PLANT & CO-GENERATION
3. WEST FLAGPOLE
5. EAST FLAGPOLE
6. GAS METER PAD
8. OXYGEN STORAGE PAD
9. GAS BOTTLE STORAGE
10. BUS SHELTER
11. SPINAL CORD INJURY
12. EMERGENCY WATER STORAGE
13. VMRF BUILDING
14. MRI BUILDING
16. HAZARDOUS MATERIAL STORAGE BUILDING
17. FINISHES STORAGE METAL BUILDING
18. WASTE FACILITY
19. HAZARDOUS MATERIAL STORAGE (CONEX BOX)
20. GROUNDS AND STORAGE (CONEX BOXES)
21. UNDERGROUND FUEL STORAGE TANKS
22. SAFETY (MODULAR BUILDING)
23. MRF (MODULAR BUILDING)
27. ADMINISTRATION BUILDING
28. PARKING GARAGE 1 STRUCTURE
31. PARKING GARAGE 2 STRUCTURE
BUILDING SITE LEGEND
V V
V V
VSCOPE OF WORK
LEVEL - 4
SCOPE OF WORK
LEVEL - 6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
DESIGN DEVELOPMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
NOT FOR CONSTRUCTION
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:0
P
M
GI-005
EXISTING SITE PLAN
(FOR REFERENCE)
11/06/20
1" = 80'-0"SITE PLAN (FOR REFERENCE) 1
N
Revisions: Date:
ISSUED FOR 65% C.D. 2020-07-10
ISSUED FOR 65% C.D. 2020-09-02
ISSUED FOR 100% C.D. 2020-10-02
ISSUED FOR CONSTRUCTION 2020-11-06
ISSUED FOR CONSTRUCTION 2020-12-04
MEDICAL
CENTER
L
IC
ENSED ARCH IT
E C
T
S T
A T
E
OF CA L I FO
R N
I AJUNE 2021
MACDONALD
JOSEPH H.
RM
EXAM
4286B
RM
EXAM
4286A
RM
EXAM
RM
EXAM
RM
EXAM
OFFICE(S)
OFFICE(S)
OFFICE(S)
437O
OFFICE(S)
OFFICE
4088B
OFFICE(S)
4088A
OFFICE(S)
4088C (S)
OFFICE
4518A
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S) 4081
OFFICE(S)
OFFICE(S)
4086A
OFFICE(S)
OFFICE
OFFICE
OFFICE
4025C
OFFICE
4025B
OFFICE
4025A
OFFICE
4024C
OFFICE
4024B
OFFICE
4024A
OFFICE
OFFICE
OFFICE
OFFICE
PHYS.
4085D
EXAM RM
4085C
EXAM RM
4085B
EXAM RM
EXAM RM
4085A
EXAM RM
EXAM RM
RM
EXAM
OFFICE(S)
OFFICE(S)
OFFICE(S)
RM
EXAM
TOILET(S)
TOI
4006A
PHYSICIAN
PHYSICIAN
4365 4367
HOLDING
RESIDENT
ONE BED
RESIDENT
ONE BED
TELECOM 4156
ANTE RM
STOR.
EQUIP.
BREAK RM
4095A
LAUNDRY
UTILITY
CLEAN
CORR.
CORR.
DAY RM
TOI. (S)
4157A
TOI.
4158A
TOI.
KEEPING
HOUSE
PHYSICIAN
CONFERENCE
SW2-4
STAIR
BREAK
(S)
OFFICE
CONFERENCE 4039
CORR.
SCANNER
PET
LAB
LAB 4064
LAB
TOI.
SHOWER
4070A
RM
EXAM
4070C
LAB
4070D
LAB
CORR.
CORR.
RECEPTION
CORR.
MED
NUC
4070B
TOILET
NURSING
EDUCATION
MULTI OFF.
CORR.
4078B
LAB
COMPUTER
4027B
STOR.
FILM
PHYSICIAN4027A
HAC
SW1-4
STAIR
HAC
4027C
CORR.
SW9-4
STAIR
CORR.
4016A
STOR.
GEN.
THERAPY
RESP
LAB
SIM
OFFICE(S)
CORR.4015A
CONTROL
LOBBY
SW10-4
STAIR
T AND L
PHYS.
4158A
TOI. (M)
4000A
RECEPTION
RESTROOM
(E)
4500A
COUNTER
GAMMA WELL
CORR.
EP LAB
EXAM ROOM
SCRUB RM
ROOM
EQUIPMENT
TRANSFER
CENTER
4039A
OFFICE
RECEPTION
4039A
CORRIDOR
OFFICE(S)
OFFICE(S)
OFFICE
STUDIO
4046B
OFFICE
4046A
STUDIO
STUDIO
ILLUSTRATION
40465A
STUDIO
STUDIO
STUDIO
4049B
STUDIO
40465B
STUDIO
EP LAB
OFFICE
OFFICE(S)
CAB DESK
FEC
2.1
2.1
3.1
3.1
7.1
7.1
9.1
9.1
9.5
9.5
9.4
9.4
G G
G.1 G.1
H H
J J
J.1 J.1
J.5 J.5
J.4 J.4
K K
L L
L.1 L.1
M M
4.2
4.2
403 SF
SCAN
124 SF
EXAM RM
123 SF
COMPUTER RM
29 SF
EQUIPMENT RM
FEC
FEC
51' - 9"
Level 4
51' - 9"
Level 4
39 SF
EQUIPMENT RM
4.3
4.3
4.1
4.1
3.2
3.2
5.1
5.1
5.2
5.2
5.3
5.3
LOBBY
4000B
CORR
CORRIDOR
CORR
5.7
5.7
1. THE BUILDING IS BE EQUIPPED THROUGHOUT WITH AN AUTOMATIC
SPRINKLER SYSTEM
GENERAL NOTES LEGEND
EXIT SIGN: SINGLE FACE. ARROW INDICATES
DIRECTION
EXIT SIGN: DOUBLE FACE. ARROW INDICATES
DIRECTION
ROOM NAME
ROOM NAME
ROOM NUMBER
ACCESSIBLE PATH OF TRAVEL
FIRE EXTINGUISHER
(E) EXIT SIGNS TO REMAIN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:0
P
M
GI-100
ACCESSIBILITY PATH OF TRAVEL
11/06/20
1/8" = 1'-0"LEVEL 4 - ACCESSIBILITY PATH OF TRAVEL 1
N
Revisions: Date:
ISSUED FOR 65% C.D. 2020-09-02
ISSUED FOR 100% C.D. 2020-10-02
ISSUED FOR CONSTRUCTION 2020-11-06
ISSUED FOR CONSTRUCTION 2020-12-04 L
IC
ENSED ARCH IT
E C
T
S T
A T
E
OF CA L I FO
R N
I AJUNE 2021
MACDONALD
JOSEPH H.
EXAM RM
LINEN
(S)
TOILET
CORR.
SCAN
OFFICE(S)
OFFICE(S)
OFFICE(S)
437O
OFFICE(S)
OFFICE
4088B
OFFICE(S)
4088A
OFFICE(S)
4088C (S)
OFFICE
4518A
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S)
OFFICE(S) 4081
OFFICE(S)
OFFICE(S)
4086A
OFFICE(S)
OFFICE
OFFICE
OFFICE
4025C
OFFICE
4025B
OFFICE
4025A
OFFICE
4024C
OFFICE
4024B
OFFICE
4024A
OFFICE
OFFICE
OFFICE
OFFICE
4085D
EXAM RM
4085C
EXAM RM
4085B
EXAM RM
EXAM RM
4085A
EXAM RM
EXAM RM
RM
EXAM
OFFICE(S)
RM
EXAM
TOILET(S)
TOI
4365 4367
HOLDING
BREAK RM
4095A
LAUNDRY
UTILITY
CLEAN
CORR.
CORR.
DAY RM
TOI. (S)
PHYSICIAN
CONFERENCE
SW2-4
STAIR
BREAK
(S)
OFFICE
CONFERENCE 4039
CORR.
SCANNER
PET
LAB
LAB 4064
LAB
TOI.
SHOWER
4070A
RM
EXAM
4070C
LAB
4070D
LAB
CORR.
CORR.
RECEPTION
CORR.
MED
NUC
4070B
TOILET
NURSING
EDUCATION
MULTI OFF.
CORR.
4078B
LAB
COMPUTER
4027B
STOR.
FILM
PHYSICIAN4027A
HAC
SW1-4
STAIR
HAC
4027C
CORR.
SW9-4
STAIR CORR.
4016A
STOR.
GEN.
THERAPY
RESP
LAB
SIM
OFFICE(S)
CORR.4015A
CONTROL
SW10-4
STAIR
T AND L
4158A
TOI. (M)
4000A
RECEPTION
RESTROOM
(E)
4500A
COUNTER
GAMMA WELL
CORR.
EP LAB
EXAM ROOM
SCRUB RM
ROOM
EQUIPMENT
TRANSFER
CENTER
4039A
OFFICE
RECEPTION
4039A
CORRIDOR
OFFICE(S)
OFFICE(S)
OFFICE
STUDIO
4046B
OFFICE
4046A
STUDIO
STUDIO
ILLUSTRATION
40465A
STUDIO
STUDIO
STUDIO
4049B
STUDIO
40465B
STUDIO
EP LAB
OFFICE
OFFICE(S)
2.1
2.1
3.1
3.1
7.1
7.1
9.1
9.1
G G
G.1 G.1
H H
J J
J.1 J.1
J.5 J.5
J.4 J.4
K K
L L
L.1 L.1
M M
403 SF
SCAN
124 SF
EXAM RM
123 SF
COMPUTER RM
18' - 0"
5'
0"
0"
6"
8"
9'
2"
14' - 0"
8' - 5"
8' - 8"
0"
37' - 0"
6' - 6"
29 SF
EQUIPMENT RM
FEC
FEC
51' - 9"
Level 4
51' - 9"
Level 4
1"
39 SF
EQUIPMENT RM
452019"-11"
4.2
4.2
GI5
GI2
GI2
GI2
GI2
GI5
4.3
4.3
4.1
4.1
3.2
3.2
5.1
5.1
5.2
5.2
5.3
5.3
14' - 6"
'-6
12' - 0"
7'
7"
7' - 0"
15' - 0"
2'
0"
9'
4"
3' - 6"
5.7
5.7
EGRESS CALCULATIONS
STAIR WIDTH REQUIREMENTS:
TOTAL OCCUPANTS:
STAIRS PROVIDED:
STAIR WIDTH REQUIRED:
STAIR WIDTH PROVIDED:
EXIT WIDTH REQUIREMENTS:
TOTAL OCCUPANTS
EXITS PROVIDED:
EXIT WIDTH REQUIRED:
EXIT WIDTH PROVIDED:
PATH OF EGRESS MAX LENGTH:
TRAVEL DISTANCE TO NORTHWEST STAIR:
TRAVEL DISTANCE TO SOUTHWEST STAIR:
DEPARTMENT TOTAL AREA:
0.3" PER OCCUPANT
14.1" 56"
0.2" PER OCCUPANT
9.4" 48"
200'-0" 181'-2" 180'-7"
7955 SF NET
8178 SF GROSS
IBC 2018 1005.3.1
IBC 2018 TABLE 1004.5
IBC 2018 TABLE1006.3.2
(GROUP I-2 COMPLYING
WITH SECTION 407.4)
IBC 2018 1005.3.2
IBC 2018 TABLE 1004.5
IBC 2018 TABLE1006.3.2
(GROUP I-2 COMPLYING
WITH SECTION 407.4)
IBC 2018 TABLE 1017.2
1. THE BUILDING IS BE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER
SYSTEM
2. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT
THE USE OF A SPECIAL KEY OR SPECIAL KNOWLEDGE OR EFFORT
(2018 IBC 1010.1.8)
3. "THE MEANS OF EGRESS, INCLUDING EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL
TIMES THE BUILDING SPACED SERVED BY THE MEANS OF EGRESS IS OCCUPIED." (2018 IBC
1008.2)
4. IN GROUP I-2 OCCUPANCIES WHERE TWO OR MORE EXITS ARE REQUIRED, ON THE
EXTERIOR LANDINGS REQUIRED BY SECTION 1010.1.6, MEANS OF EGRESS ILLUMINATION
LEVELS FOR THE EXIT DISCHARGE SHALL BE PROVIDED SUCH THAT FAILURE OF A SINGLE
LAMP IN A LUMINAIRE SHALL NOT REDUCE THE ILLUMINATION LEVEL ON THAT LANDING TO
LESS THAN 1 FOOTCANDLE (11 LUX).
5. PROVIDE TACTILE ROOM IDENTIFICATION SIGNAGE THROUGHOUT. REFER TO SHEET G-005
6. EXISTING EXIT SIGNS CONTRACTOR TO VERIFY AND TO BE PROVIDED AS REQUIRED.
GENERAL NOTES
LEGEND
COMMON - PATH OF TRAVEL/ TRAVEL DISTANCE
EXIT SIGN: SINGLE FACE. ARROW INDICATES
DIRECTION
EXIT SIGN: DOUBLE FACE. ARROW INDICATES
DIRECTION
FIRE EXTINGUISHER CABINET
ROOM NAME
ROOM NAME
ROOM NUMBER
EXIT ACCESS - PATH OF TRAVEL / TRAVEL
DISTANCE
FEC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:0
P
M
GI-101
EGRESS PLAN
11/06/20
1/8" = 1'-0"LEVEL 4 - EGRESS PLAN 1
NUC-MED DEPARTMENT OCCUPANCY
ROOM NAME
ROOM
NUMBER
AREA
OCCUPANT
LOAD
FACTOR
OCCUPANTS
HAC 4058 36 SF 300 -
LAB 4059 165 SF 200 1
LAB 4062 155 SF 200 1
LAB 4064 119 SF 200 1
EXAM RM 4066 103 SF 100 2
EQUIPMENT RM 4068 29 SF 300 -
EXAM RM 4069 111 SF 100 2
PET SCANNER 4070 673 SF 240 3
EXAM RM 4070A 102 SF 100 2
LAB 4070C 245 SF 200 2
LAB 4070D 66 SF 200 1
GAMMA WELL COUNTER 4500A 59 SF 100 1
EXAM RM 4501 124 SF 100 2
COMPUTER RM 4502 123 SF 300 -
SCAN 4503 403 SF 240 2
CONTROL 4504 170 SF 100 2
SCAN 4505 371 SF 240 1
SCAN 4506 383 SF 240 2
EXAM RM 4507 111 SF 100 2
CLEAN UTILITY 4508 66 SF 300 -
OFFICE 4510 119 SF 100 2
BREAK 4511 175 SF 15 13
CONFERENCE 4513 275 SF 15 19
OFFICE (S) 4514 109 SF 100 2
OFFICE (S) 4515 132 SF 100 2
OFFICE (S) 4517 157 SF 100 2
OFFICE (S) 4518 123 SF 100 2
RECEPTION 4519 374 SF 15 25
EQUIPMENT RM 4520 39 SF 300 -
N
EGRESS KEYNOTES
GI2 PROVIDE SIGN WITH A WORD "EXIT ROUTE". INSTALL ADJACENT TO LATCH SIDE OF
DOOR AT C. TO C. 60" A.F.F. SEE DETAIL 9/G-003.
GI5 EXISTING SIGNAGE: TACTILE EXIT SIGN WITH THE WORDS "EXIT STAIR DOWN, SEE
DETAIL 9/GI-003
Revisions: Date:
ISSUED FOR 35% C.D. 2019-02-06
ISSUED FOR 65% C.D. 2019-04-12
ISSUED FOR 65% C.D. 2020-07-10
ISSUED FOR 65% C.D. 2020-09-02
ISSUED FOR 100% C.D. 2020-10-02
ISSUED FOR CONSTRUCTION 2020-11-06
ISSUED FOR CONSTRUCTION 2020-12-04
L
IC
ENSED ARCH IT
E C
T
S T
A T
E
OF CA L I FO
R N
I AJUNE 2021
MACDONALD
JOSEPH H.
FEC
UPDNUPDN
G G
G.1 G.1
H H
J J
J.1 J.1
J.5 J.5
J.4 J.4
SCAN
COMPUTER
RM
NUCMED
SHOWER
CORRIDOR
TOILET
4070B
LAB
4070D
EXAM RM
4070A
LAB
4070C
RESTROOM
PET
SCANNER
WAITING
CORRIDOR
HAC
LAB
EXAM RM
EXAM RM
TOILET
SCAN
EXAM RM
CLEAN
UTILITY
TOILET
4509OFFICE
BREAK
CONFERENCE
LAB
SHOWER
GAMMA
WELL
COUNTER
4500A
EXAM RM
MIN.
6' - 6"
MIN.
6' - 0"
M
IN
6'
0"
4.2
4.2
4.3
4.3
4.1
4.1
3.2
3.2
5.1
5.1
5.2
5.2
5.3
5.3
EDUCATION
TRAINING
OFFICE
EXAM RM
4085D
OFFICE(S)
COMPUTER
LAB
4078B
CONFERENCE
EMPLOYEE
EDUCATION CENTER
KEYPLAN- LEVEL 4
HA-001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
CONSTRUCTION DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
664-CSI-1154W NUCLEAR MEDICINE PET- CT 2
SAN DIEGO, CA
IDS GROUP INC.
1 PETERS CANYON RD. STE. 130
IRVINE, CA 92606
949.387.8500
C U se rs
\M a ri lo u .f ra n ci sc o
\D o cu m e n ts \V
A S
D -N u c-
M e d
A
R C
H -C e n tr a l_
R T
V m a ri lo u .f ra n ci sc o .r vt
/3
/2
:1
:0
P
M
HA-001
4TH FLOOR - HAZARDOUS MATERIAL
ABATEMENT
11/06/20
GENERAL PLAN NOTES:
1. CONTAINMENT BARRIER FOR WORK AREA MUST BE SET UP AND APPROVED BY A
VETERANS' AFFAIRS REPRESENTATIVE, PRIOR TO ANY DEMOLITION OR
CONSTRUCTION. REFER TO SHEET HA-003.
2. ALL HAZARDOUS MATERIAL AND DEBRIS ARE TO BE CONTAINED AND SEALED BEFORE
TRAVELLING OUTSIDE THE SCOPE OF WORK AREA.
3. CONTRACTOR IS TO FOLLOW PATH OF TRAVEL SHOWN ON THESE DRAWINGS FOR
REMOVAL AND DISPOSAL OF HAZARDOUS MATERIALS AND DEBRIS. IF A DEVIATION
FROM THE PATH SHOWN HAS BEEN REQUESTED, CONTRACTOR IS TO NOTIFY THE
ARCHITECT OF RECORD AND VETERANS' AFFAIR REPRESENTATIVE.
4. ONLY TAKE DEBRIS THROUGH THE ELEVATOR DESIGNATED ON THE PLANS. IF AN
ALTERNATIVE ELEVATOR HAS BEEN REQUESTED, CONTRACTOR IS TO NOTIFY THE
ARCHITECT OF RECORD AND VETERANS' AFFAIR REPRESENTATIVE. REFER TO PLANS
ON HA-002.
5. ALL DEBRIS IS TO BE TAKEN TO THE LOADING DOCK AT THE NORTH SIDE OF HOSPITAL,
ACCESSED FROM THE BASEMENT FLOOR. AS SHOWN ON THE PLANS. REFER TO PLANS
ON HA-002.
6. REFER TO OTHER DRAWINGS, INCLUDING ARCHITECTURAL DEMO, MECHANICAL,
PLUMBING, ELECTRICAL, AND STRUCTURAL SHEETS FOR FULL SCOPE OF WORK.
RECOMMENDED WORK/ABATEMENT SEQUENCE:
1. SETUP THE CONTAINMENT AT WORK AREAS DEPICTED ON PLANS. PROVIDE NEGATIVE
AIR MACHINES, AND ALLOW TO REACH AT MINIMUM -0.02" WC PRESSURE
DIFFERENTIAL.
2. ERECT THE HARD BARRIERS AROUND WORK AREAS.
3. REMOVE AND HEPA VACUUM CEILING TILES AS REQUIRED BY SCOPE OF WORK
(DEBRIS ATOP CEILING TILES ASSUMED POSITIVE).
4. ABATE FLOOR TILES AND DRYWALL/JOINT COMPOUND AS REQUIRED WITHIN THE AREA
OF WORK.
5. SPOT ABATE FIRE PROOFING ON STRUCTURAL BEAMS AND OTHER STRUCTURAL
MEMBERS ABOVE CEILING IN THE WORK AREAS..
6. REMOVE LEAD-CONTAINING FINISHES THROUGHOUT.
7. AT CONCLUSION OF ABATEMENT, CONDUCT FINAL CLEANUP.
8. VISUAL INSPECTION BY CONSULTANT.
9. ENCAPSULATION OF WORK AREA.
10. FINAL AIR CLEARANCE BY CONSULTANT.
1. HAZARDOUS MATERIAL ABATEMENT PLANS AND SPECIFICATIONS HAVE BEEN PREPARED ON THE BASIS OF EXISTING DOCUMENTS AND SITE INSPECTIONS. LOCATION OF MATERIALS SCHEDULED FOR ABATEMENT AND DEMOLITION ARE GENERAL IN NATURE. DRAWINGS ARE INTENDED TO PROVIDE AN APPROXIMATE LOCATION OF MATERIALS TO BE REMOVED. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND QUANTITIES OF MATERIALS TO BE REMOVED. PRIOR TO BID.