9. B-20245 Component-Section Report updated 15 Feb 21.xlsx

XLSX spreadsheet 81 KB Posted

Attached to
Design Charrette for Repair Consolidated Support Building 20245
Solicitation number
FA9401-21-R-0003
Issued by

About this file

This is a solicitation for design services related to repairing and modernizing Building 20245 at Kirtland Air Force Base. The Department of the Air Force Materiel Command Nuclear Weapons Center is seeking a final Facility Sustainment Restoration Modernization Planning Charrette Report, financial documents, design and construction specifications, design analysis, and construction cost estimate for a 35% conceptual design to repair building systems. Firms must attend a mandatory site visit and submit responses using the attached SF1442 form by the response date. The selected firm will provide tailored front-end specifications and project documents to repair Building 20245 in support of the Air Force's Sustainment, Restoration and Modernization program.

View the file

Other files

File Type Posted
18. Site Visit Sign In Sheet.pdf PDF
17. SF330.pdf PDF
Solicitation Amendment 3.pdf PDF
19. Questions and Answers for Solicitation.pdf PDF
Solicitation Amendment FA940121R00030002.pdf PDF
SF330.pdf PDF
Amendment FA940121R00030001 SF 30.pdf PDF
7. Welcome Center Talking Paper.pdf PDF
13b. HVAC Waste Water Discharge Request Form.pdf PDF
2. CDRLs MHMV100050CR Repair Systems B20245.pdf PDF
6b. Comm Div Specs.pdf PDF
1. Statement of Objectives MHMV 100050CR 28 Oct 20.pdf PDF
8. Section Data Sheet programming.xlsx XLSX spreadsheet
16. DD1391c TEMPLATE.docx DOCX document
11. AFCFS and IFS for KAFB.pdf PDF
10. AF_Sust_Scoresheet_GP_vFeb2017.xls XLS spreadsheet
1a. Appendix 1 FSRM PCR Template.docx DOCX document
15. DD1391 FSRM TEMPLATE 2020-02-05.docx DOCX document
6a. Front End Specs Template.pdf PDF
5a. Floor plan with estimated sqft. bldg. 20245.pdf PDF
3. Schedule of Design Submittals.pdf PDF
Combined Synopsis Solicitation - Design Charette Consolidated Support Bldg..pdf PDF
Solicitation - FA940121R0003.1.pdf PDF
4. Bid Tab Design Charrette MHMV100050CR.pdf PDF
12. AFGSC-Logo-grayscale.jpg JPG image
5c. As builts - Bldg 20245.pdf PDF
14. FY22-26_AFCAMP_Business_Rules_v2_marked up_12Jun2020.pdf PDF
5b. Floor plan with existing organizations bldg. 20245.pdf PDF
9. B-20245 Component-Section Report 6-2-2020.xlsx XLSX spreadsheet
13a. Environmental Check list.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Equipment Details

Final 04 - Equipment Details Report
Generated From BUILDER SMS on: 2/18/2021 12:54:10 PM
Site NumberSite NameComplex NameBuilding NumberBuilding NameRPUIDSystemComponentMaterial/Equipment CategoryComponent SubtypeSection NameSection Install DateInstall Date SourceSection QuantityUoMSection CIRSL (years)Section IDID NumberEquipment TypeEquipment MakeModelSerial NumberCapacityManufacturerDate ManufacturedDate InstalledControl Type MakeWarranty DateWarranty CompanyLocationCommentWarranty Date 2Warranty Company 2Section Detail ID
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690B20 EXTERIOR ENCLOSUREB2010 EXTERIOR WALLSB201001 EXTERIOR CLOSUREConcrete BlockEXT WALL CON BLK 12005Estimated4,331SF843627890c21-b2df-44a8-942d-fd8a1cf53c98NANANANULL2005WEST EXTERIORe03f97f3-225e-40fc-9b0a-dd66d9411ef9
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690B30 ROOFINGB3010 ROOF COVERINGSB301002 LOW SLOPE ROOF SYSTEMSSingle Ply MembraneROOF LOW MEMBR 11988Estimated66,649SF3000ee27972-86d8-4cfe-a5af-3d593f4be150NANANANULL1988ROOFadabb5e5-3277-4975-9687-8be1c70bfcdf
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690B30 ROOFINGB3010 ROOF COVERINGSB301006 ROOF OPENINGS AND SUPPORTSHatchesROOF OPEN HATCH 12005Estimated1EA6214561b5452-3c6c-4ee1-b74f-b3e1f731669fNANANANULL2005ROOF CENTERe1507af4-df5f-4fba-b4fc-c2a8340c3a54
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690B30 ROOFINGB3010 ROOF COVERINGSB301006 ROOF OPENINGS AND SUPPORTSSkylightsROOF OPEN SKYLT 12005Estimated96SF621498ebee21-3424-4591-a239-9d6466c27b69NANANANULL2005ROOF CENTER98ebee21-3424-4591-a239-9d6466c27b69
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D20 PLUMBINGD2010 PLUMBING FIXTURESD201006 DRINKING FOUNTAINS AND COOLERSDrinking FountainFLR1 FIXTR DRNK FTN 11999Input1EA7810a74ee845-9e03-4b59-92be-d2b110a93339MHMV012869ER92-8C070227077NAELKAY MANUFACTURING CO.1999CORRIDORe38695de-e628-4c22-a12e-4b7495595cca
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D20 PLUMBINGD2020 DOMESTIC WATER DISTRIBUTIOND202002 VALVES & HYDRANTSBackflow Preventer - 1" pipeMECH VLV BKFLO PREV 11999Input1EA7810400ce49c-9720-4218-8aba-4725f45f5c33MHMV000636975XL13578721 INWILKINS-ZURN1999MECH RM4450, Backflow Preventer3f1fbb7c-0599-42d8-84b2-dc6963ba971c
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D20 PLUMBINGD2020 DOMESTIC WATER DISTRIBUTIOND202002 VALVES & HYDRANTSBackflow Preventer - 2" pipeMECH VLV BKFLO PREV 21999Input1EA6877744184c-36af-40f6-8a2a-081a43dcb480MHMV000634825YA1692622 INFEBCO1999WEST EXTERIOR4450, Backflow Preventere25b1596-9bee-4581-9e30-8599ef8fd54d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D20 PLUMBINGD2020 DOMESTIC WATER DISTRIBUTIOND202003 DOMESTIC WATER EQUIPMENTOtherMECH WTR EQ MTR 11999Input1EA7810e7e8c212-463f-44b7-a3de-eb566ec6ba68MHMV000635RB2 GAL97075401NAMAGNUM1999MECH RM[7Feb14-JA-AECOM] Size not given on nameplate. Water meter.44569A2, Water Meters1054c0ea-6696-4be9-a70a-08cd064ad355
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D20 PLUMBINGD2020 DOMESTIC WATER DISTRIBUTIOND202003 DOMESTIC WATER EQUIPMENTWater Heaters, Commercial, Gas - 240 MBH input, 230 GPHMECH WTR HTR COM GAS 11999Input1EA60249a8365b-b134-4f9f-89a7-ee73920d80a8MHMV012868BTC 250A 962LH96-0571936-S54100 GAL 250 MBH INPUTA.O. SMITH1999CUSTODIAN ROOMa27e9322-2252-4617-a6ff-3f34623b2995
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3010 ENERGY SUPPLYD301002 GAS SUPPLY SYSTEMGas MeterEXT GAS SUP MTR 11999Input1EA731766cf7196-a5f4-410a-b870-f34e6a70e3d0MHMV006097NA96S6815655800 CFH ESTAMERICAN METER CO.1999WEST EXTERIOR[Matthew Vella on 8/8/2017 4:10:59 PM]
THE DATA PLATE IS FADED AND ILLEGIBLE.a38e18dc-731e-49af-8781-60ee4c71d325
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3020 HEAT GENERATING SYSTEMSD302001 BOILERSGas, Hot Water - 1200-1800 MBHMECH BLR GAS HT WTR 12020Input1EA10029b9d10933-c309-499a-8b30-0e4748292c77MHMV003657AR 1500FC2300014161500 MBHRIELLO2020MECH RMb16065ff-40e3-4e7e-a2c0-29150b3373ed
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3020 HEAT GENERATING SYSTEMSD302004 AUXILIARY EQUIPMENTChemical Feedwater - 175 PSIG, 5 gallonMECH AUX CHEM FDWTR TNK 11988Input1EA655f64a360d-1941-45cc-914c-4b71ec24b7eeMHMV018380NANA5 GAL ESTNA1988MECH RM[Matthew Vella on 8/8/2017 2:05:33 PM]
THIS UNIT LACKED A DATA PLATE.061015aa-d152-466d-ab63-3cb80280816d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3020 HEAT GENERATING SYSTEMSD302004 AUXILIARY EQUIPMENTChemical Feedwater - 300 lb., 5 gallon, ASMEMECH AUX CHEM FDWTR TNK 21999Input1EA655edd84b76-3356-4974-a642-60eff4649efbMHMV018324FTF-5DBNA5 GAL 300 PSI 200 FNEPTURE CHEMICAL PUMP CO.1999MECH RM[Matthew Vella on 8/8/2017 2:04:34 PM]
THE DATA PLATE LACKED REQUIRED INFORMATION.4dbee4f1-0a87-4518-802a-c9bfaa124d8a
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3020 HEAT GENERATING SYSTEMSD302004 AUXILIARY EQUIPMENTExpansion Tank - 40 galMECH AUX EXP TNK 11999Input1EA70952631576-b06d-4b63-95f5-5e45cef35eddMHMV006100C7183 7781490284240 GAL ESTWHEATLEY1999MECH RMf2e327a6-9a93-44a7-aa15-e22f55f6621f
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 1-1/2 tonEXT DX AIR COOL DIR 81999Input1EA593fb7bf50a-7bea-4dc8-8e44-3a677156b726MHMV005887CMH182200181811.5 TONSANYO ELECTRIC CO., LTD.1999WEST EXTERIORfb7bf50a-7bea-4dc8-8e44-3a677156b726
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 11988Input1EA603805d4f61-b2a4-429d-a465-cc30404f5493MHMV005928NANA5 TON ESTCOMPU-AIRE1988ROOF[3Feb14-JM-AECOM] Nameplate data not available.805d4f61-b2a4-429d-a465-cc30404f5493
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 102014Input2EA674993b556d-8d3b-437f-bf81-c4b31daaff62MHMV018370AOU18RLXFZLTN0436621.5 TONFUJITSU LTD.2014SOUTH EXTERIOR[Matthew Vella on 8/8/2017 2:38:20 PM]
THIS CONDENSER IS PART OF A SPLIT SYSTEM HEAT PUMP.44bcb320-044b-4cc7-9061-0bc2fb3296b1
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 21988Input1EA6038948b9bd-cb41-4150-ba84-02bea28eaa7bMHMV005934ACC 2G9734283-0312 TONCOMPU-AIRE1988ROOF8948b9bd-cb41-4150-ba84-02bea28eaa7b
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 32018Input1EA889d42d6a44-32c8-4966-943d-9e6ba6f7d17dMHMV000287SCS-MC-015-SAA-F2103042352 TON ESTSTULZ2018ROOFd42d6a44-32c8-4966-943d-9e6ba6f7d17d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 41999Input1EA593707d4636-99c1-4783-9881-b3e610ed9ea5MHMV005931CH243200222132 TONSANYO ELECTRIC CO., LTD.1999ROOF707d4636-99c1-4783-9881-b3e610ed9ea5
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 51999Input1EA593098488b7-d14b-4547-8963-bbae506f8b7dMHMV005932CH243200221132 TONSANYO ELECTRIC CO., LTD.1999ROOF098488b7-d14b-4547-8963-bbae506f8b7d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 62018Input1EA8894b343b3e-2b94-4967-b85b-3e2906aa7f82MHMV000288SCS-MC-015-SAA-F2103042732 TONSTULZ2018ROOF4b343b3e-2b94-4967-b85b-3e2906aa7f82
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 71999Input1EA593b9b79ff5-a21e-4902-8ed4-4855b36d40e8MHMV005876CH242200319742 TONSANYO ELECTRIC CO., LTD.1999WEST EXTERIORb9b79ff5-a21e-4902-8ed4-4855b36d40e8
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3030 COOLING GENERATING SYSTEMSD303002 DIRECT EXPANSION SYSTEMSCondenser, DX, Air Cooled - Direct Drive, 2 tonEXT DX AIR COOL DIR 91999Input1EA59329c27edd-b108-4d8b-8669-59664cd51f95MHMV005892CH242200323742 TONSANYO ELECTRIC CO., LTD.1999WEST EXTERIOR29c27edd-b108-4d8b-8669-59664cd51f95
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGAir Separator - Air control, air separator, 6" diameter, includes strainerMECH AIR SEP 11999Input1EA8115275076cf-657d-4da7-bd75-6068d28751fcMHMV000637NANA6 IN ESTWHEATLEY1999MECH RM[Matthew Vella on 8/8/2017 2:09:00 PM]
THE DATA PLATE LACKED REQUIRED INFORMATION.8f4ebf27-69fe-4be8-86ec-cfdc362b9618
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1070 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.ab1aa68b-bfc1-4cf4-be5d-779b6897eb71
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1110 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.779a9165-f3b5-4440-a91d-8e41b294f268
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1125 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.f407993c-bf90-4689-ae4d-270c7060f89e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1155 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.f2aa5b8f-1b4f-4da0-b1bd-274d9496fd86
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1120 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.45a4d375-931d-4404-8a2d-c4a3642d2d7e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1120 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.d996626c-027f-414e-8ac2-c0d01dab0818
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 1250 CFM, Hot Water ReheatFLR1 AIR VAV 31999Input7EA7093624d326-5661-4283-9403-ee50b09920d0NANANA1100 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.b6d4c787-8047-4c71-bdf4-ea649211e6a0
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal - 800 CFM, Hot Water ReheatFLR1 AIR VAV 41999Input1EA709e88123af-76a8-434e-a851-6c434558df94NANANA700 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.bce829ec-5921-43a0-960b-d6f8615b623f
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA2310 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.c4290ea3-4751-442c-b7cf-583d15c9e70a
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA2250 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.e528769b-788e-4fac-abac-5311c044b157
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1400 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.94774579-fe44-4d61-9cf1-60be3253552e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1425 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.d00bc9aa-ddeb-46ac-b32d-6ae46729d84d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1560 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.743215e5-a0eb-4a85-92b8-338a44191414
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1650 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.d0cbfa3c-a0f9-410c-b6b6-10f4a9fde904
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1880 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.639913eb-944d-4ab3-94f8-2bea63509c60
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1960 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.1a488630-1abf-4521-932f-c5fcff18e3b8
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA2375 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.e0618234-3f70-4880-b7e8-d3dde3c558df
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1720 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.7a38b2af-e9b9-4afc-a35f-9af16c2ef7ea
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA2210 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.e2b1b7a2-d603-413e-bb5c-a592c937171d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1700 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.91c806f1-9959-41cc-aac7-c098c4cfbf8e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1680 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.4f1762c6-cb6d-491c-8c51-b3946c06284d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1640 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.0dea57a7-4f16-40a3-ae52-890a4597c427
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1540 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.bfb1d192-6de4-44fc-ba0b-95ec1b039c93
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1590 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.83965cb1-96ef-40a3-8d2a-95486469841d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1460 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.07f4f68b-cc3d-4218-8287-7165c2666327
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA2400 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.212d5f4f-7f35-4af7-9d13-f4756e5fc7bd
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1760 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.0b9cd834-4ea0-4f57-b546-f5adb47c8902
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1500 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.4527eb1c-bd03-4ce2-9532-f2fb2edfe7b2
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 1500 CFM, Hot Water ReheatFLR1 AIR VAV 11999Input21EA709a642d880-3b17-4d29-8870-9178076ef991NANANA1650 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.b7cc9fa4-27e0-4b8a-bb36-efab465fe470
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304001 AIR DISTRIBUTION, HEATING & COOLINGVAV Terminal, Fan Powered - 400 CFM, Hot Water ReheatFLR1 AIR VAV 21999Input1EA709290d77f3-1c05-469c-9671-d062c1970d1bNANANA300 CFMNA1999[Matthew Vella on 8/8/2017 3:49:26 PM]
THESE VAV BOXES SUPPORT THE ROOFTOP UNITS. TO POPULATE THE DATABASE, THE INFORMATION WAS CAPTURED FROM THE BCE DRAWING ARCHIVES. UNFORTUNATELY, NO LOCATION INFORMATION WAS AVAILABLE FOR THESE UNITS. FURTHER, THE BOXES WERE LOCATED ABOVE THE CEILING TILES AND WERE OUT OF REACH. THEY WERE INACCESSIBLE FOR PHOTOGRAPHY OR BAR CODING. CONDITION RATINGS ARE BASED ON TESTIMONY FROM OCCUPANTS OF THE FACILITY.216794f3-4008-4e31-a4f3-96d6af50cb28
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304003 HOT WATER DISTRIBUTION SYSTEMSCirculating Pump, End Suction - 3" size, 5 HP, to 225 GPMMECH HOT WTR CIRC PUMP 12006Input1EA6454c8e0b2e-6a07-4184-bcad-e876148615d4MHMV00588806-1459349341A-BF; 1.25 X 2 X 9B116 GPM 50 FT 5 HPAURORA PUMP2006MECH RMecf5864b-68e5-44e7-b2a3-e6e4c67c25eb
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304007 EXHAUST SYSTEMSFan System, Wall Exhaust - Wall Exhaust, 6175 CFMMECH DISTR WALL EXH 11988Input1EA4710f274f5a-251e-470e-9f2c-230842e275a5NANANA1000 CFM ESTNA1988ELEC RM 130[Matthew Vella on 8/8/2017 10:33:35 AM]
THIS UNIT WAS MOUNTED OUT OF REACH. NO FURTHER DATA COULD BE COLLECTED.4450, Exhaust - Wall Fan0334ba4a-795e-4328-8d23-5414513a9d8e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3040 DISTRIBUTION SYSTEMSD304007 EXHAUST SYSTEMSFan System, Wall Exhaust - Wall Exhaust, 6175 CFMMECH DISTR WALL EXH 21988Input1EA220d54c2381-aa22-4ffd-b450-9c5f19b70050NANANA1000 CFM ESTNA1988MECH RM[Matthew Vella on 8/8/2017 3:47:41 PM]
THIS EXHAUST FAN WAS INACCESSIBLE DUE TO ITS MOUNTING HEIGHT.4450, Exhaust - Wall Fan3a89ac7a-1fc0-40f9-9935-0c58a7787b5f
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305002 UNIT HEATERSHydronic - 20 MBHMECH UNT HTR HYDR 11999Input1EA731068c088ad-396d-4ab4-ba74-302f98b1f837MHMV018369NANA10 MBHREZNOR, LLC1999MECH RM[Matthew Vella on 8/8/2017 2:02:30 PM]
THIS HEATER WAS MOUNTED OUT OF REACH. THE DATA PLATE WAS NOT LEGIBLE AT THAT HEIGHT.152b8f3b-4d7e-464b-97cf-a4348ae9d55c
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 1.5 tonFLR1 FCU DX 21999Input4EA5931ad4aeeb-7b5d-4f98-b196-7f9d2ceb8086NANANA0.75 TONSANYO ELECTRIC CO., LTD.1999FINANCE SERGEANT'S RMTHIS ROOM WAS INACCESSIBLE AT THE TIME OF ASSESSMENT. NO DATA COULD BE CAPTURED FOR THIS UNIT NOR COULD IT BE PHOTOGRAPHED.1d75bd60-7623-440e-a2e1-80110d607bbb
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 1.5 tonFLR1 FCU DX 21999Input4EA5931ad4aeeb-7b5d-4f98-b196-7f9d2ceb8086MHMV013048KHS242200184742 TONSANYO ELECTRIC CO., LTD.1999FINANCE COMMANDER'S OFFICE8a5ef0ee-498f-4877-bab2-b3568445aded
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 1.5 tonFLR1 FCU DX 21999Input4EA5931ad4aeeb-7b5d-4f98-b196-7f9d2ceb8086MHMV013047KHS242200185742 TONSANYO ELECTRIC CO., LTD.1999FINANCE CONFERENCE RM1cab8cc1-ab8c-4579-bde1-c85680035c37
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 1.5 tonFLR1 FCU DX 21999Input4EA5931ad4aeeb-7b5d-4f98-b196-7f9d2ceb8086MHMV013045KMH092200632810.75 TONSANYO ELECTRIC CO., LTD.1999FINANCE146f71e3-a7c3-4d51-8ca0-45f36131941d
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 1.5 tonFLR1 FCU DX 21999Input4EA5931ad4aeeb-7b5d-4f98-b196-7f9d2ceb8086MHMV013046KMH092200632810.75 TONSANYO ELECTRIC CO., LTD.1999FINANCE RM 233ce37df-6463-4b93-b505-ddbdf83dfc4f
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 5 tonFLR1 FCU DX 11988Input2EA603ee483828-c56e-4a33-bd32-172b4dae39e8MHMV018363NANA5 TON ESTCOMPU-AIRE1988RM 116A[Matthew Vella on 8/8/2017 10:28:05 AM]
THIS FAN COIL UNIT IS THE INTERIOR PORTION OF AN AIR COOLED, COMPUTER ROOM AIR CONDITIONING SYSTEM. THE DATA PLATE WAS INACCESSIBLE.57fb7498-4855-4576-bdbc-f88b94b00540
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305003 FAN COIL UNITSDX - 5 tonFLR1 FCU DX 11988Input2EA603ee483828-c56e-4a33-bd32-172b4dae39e8MHMV018632NANA5 TON ESTCOMPU-AIRE1988RM 116A[Matthew Vella on 8/8/2017 10:28:05 AM]
THIS FAN COIL UNIT IS THE INTERIOR PORTION OF AN AIR COOLED, COMPUTER ROOM AIR CONDITIONING SYSTEM. THE DATA PLATE WAS INACCESSIBLE.4510a3ca-6f9a-4eab-abe7-40403078989a
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 12-1/2 ton, VAVROOF PACK RTU 11999Input1EA33076baea72-22f5-4c7f-8de1-a36e079ab04bMHMV005929NANA12.5 TON ESTMCQUAY1999ROOF[Matthew Vella on 8/8/2017 11:03:22 AM]
THE DATA PLATE WAS FADED AND PARTIALLY ILLEGIBLE.76baea72-22f5-4c7f-8de1-a36e079ab04b
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 22018Input1EA901203bc07f0-ecc6-4e9d-843f-2f7a7ee61fcbMHMV000290RN-025-3-0-EA09-000201712-BNCR1363825 TON ESTAAON, INC.2018ROOF03bc07f0-ecc6-4e9d-843f-2f7a7ee61fcb
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 32018Input1EA90120bab32f4-5202-45d6-b94e-9feb87f78099MHMV000291RN-025-3-0-EA09-000201708-BNCR1301325 TON ESTAAON, INC.2018ROOF0bab32f4-5202-45d6-b94e-9feb87f78099
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 42018Input1EA90128c5f752b-34ba-4b67-a512-107dab209016MHMV000292RN-025-3-0-EA09-000201712-BNCR1363725 TON ESTAAON, INC.2018ROOF8c5f752b-34ba-4b67-a512-107dab209016
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 52020Input1EA1001966afb24e-8bd1-4402-bfa3-05bda9556b80MHMV005240RN-025-3-0-EA09-000201911-BNCR1627425 TONAAON, INC.2020ROOF8a19ffe2-6462-4a5d-878e-73d06e93ec22
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 62020Input1EA1001955dc6db1-105e-45d6-a0b3-38980c48acc7MHMV005620RN-025-3-0-EA09-000201911-BNCR1627525 TONAAON, INC.2020ROOF8010b19b-5a76-4ff3-b79e-ea45d6a77dee
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 72018Input1EA9012c21d0953-4f86-4b87-9962-71063fa08ed0MHMV000293RN-025-3-0-EA09-000201708-BNCR1301425 TON ESTAAON, INC.2018ROOFc21d0953-4f86-4b87-9962-71063fa08ed0
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 82019Input1EA8712ffa72b88-63a9-4c7d-b73a-6dd72153454eMHMV004204RN-025-3-0-EA09-000201906-BNCR1577025 TON ESTAAON, INC.2019ROOF[Matthew Vella on 8/8/2017 11:03:22 AM]
THE DATA PLATE WAS FADED AND PARTIALLY ILLEGIBLE.ffa72b88-63a9-4c7d-b73a-6dd72153454e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3050 TERMINAL & PACKAGE UNITSD305006 PACKAGE UNITSRooftop Unit - 25 ton, VAVROOF PACK RTU 92019Input1EA871235ccee90-8b1e-4f60-bc17-eabd546ff952MHMV000294RN-025-3-0-EA09-000201907-BNCR1597725 TON ESTAAON, INC.2019ROOF[Matthew Vella on 8/8/2017 11:03:22 AM]
THE DATA PLATE WAS FADED AND PARTIALLY ILLEGIBLE.35ccee90-8b1e-4f60-bc17-eabd546ff952
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D30 HVACD3060 CONTROLS & INSTRUMENTATIOND306002 ELECTRONIC CONTROLSD.D.C controller, mechanical room, 16 pointMECH ELEC CNTRL DDC 11999Input1EA471aad408e7-037a-4000-b12a-2699dc1d9bf2MHMV005879NANANAHONEYWELL1999MECH RM[Matthew Vella on 8/8/2017 3:58:56 PM]
THIS DDC CONTROL PANEL LACKED A DATA PLATE.c9fcc4fb-db53-4e69-9ad5-d927eb1779da
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D40 FIRE PROTECTIOND4010 FIRE ALARM AND DETECTION SYSTEMSD401001 FIRE ALARM DISTRIBUTIONFire Alarm Control Panel, multizone (4) - non addressableFLR1 FIRE FACP NADD 12008Input1EA57380fb8bde-93c7-44ef-8b03-b82d651cb3dcMHMV037466FS90NA13 ZONEHONEYWELL2008ENTRANCE[Matthew Vella on 5/1/2018 4:28:11 PM]
THE FACE PANEL WAS LOCKED AND THE DATA PLATE WAS INACCESSIBLE.e8b26661-37fe-4f86-9f68-b31d3249909c
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D40 FIRE PROTECTIOND4030 STANDPIPE SYSTEMSD403001 STANDPIPE EQUIPMENT & PIPINGRiser - 6" diamFLR1 FIRE RISER 11999Input1EA300eed89bfd-68a6-43cc-abe9-809c3bbec702NANANA6 IN ESTNA1999RM 112[Matthew Vella on 5/1/2018 4:31:04 PM]
DESPITE MANY EFFORTS ATTEMPTING TO ACCESS THE FIRE RISER WHICH SERVES THE NORTHERN PORTION OF THE BUILDING, WE WERE UNABLE TO GAIN ENTRY. NO CONDITION RATING COULD BE ENTERED FOR THIS UNIT. NEITHER FACILITIES PERSONNEL NOR THE FIRE DEPARTMENT COULD OPEN THIS ROOM.dfa41636-d44b-42a8-a42c-62bdcb2fc127
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D40 FIRE PROTECTIOND4030 STANDPIPE SYSTEMSD403001 STANDPIPE EQUIPMENT & PIPINGRiser - 6" diamFLR1 FIRE RISER 21999Input2EA65573f64fec-4336-41f0-a9cb-8af34a5cd9bfMHMV034768NANA6 INGEM1999RM 125[Matthew Vella on 5/1/2018 4:29:51 PM]
THIS STANDPIPE LACKED A DATA PLATE.fe2ed002-5bc1-47d0-a816-2956861f3595
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D40 FIRE PROTECTIOND4090 OTHER FIRE PROTECTION SYSTEMSD409004 HOOD & DUCT FIRE PROTECTIONWet Chemical (includes agent containers, distribution piping and controls)FLR1 FIRE WET CHEM 12008Input1EA757a9ce5a7b-e906-4a6a-b8b8-4acad0ee562eMHMV018366WHDR-125NA2 GAL ESTKIDDE FIRE SYSTEMS2008RM 127[Matthew Vella on 8/8/2017 11:03:22 AM]
THE DATA PLATLACKED REQUIRED INFORMATION.3a0aef3b-8efe-4a74-b061-b3ffc42c20c2
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501001 MAIN TRANSFORMERSGeneralEXT XFRM MAIN 11996Input750KVA8323ae2a1cfa-725f-4a00-aeed-77da20ef5e48MHMV0060980075VP12K60A969006390750 KVACUTLER HAMMER1996WEST EXTERIOR74bf1fbb-72b2-440b-ae7d-7d4d4b8046b3
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501002 SERVICE ENTRANCE EQUIPMENTOtherSB / ELEC METER T0501111988Input3AMP82154aa77dc4-6b11-467a-be06-2b1ea55f3585MHMV006099A3TL083948052.5AELSTER GROUPWEST EXTERIOR4aa77dc4-6b11-467a-be06-2b1ea55f3585
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501003 INTERIOR DISTRIBUTION TRANSFORMERSdry-type, 480 V primary 120/208 V secondary, 300 kVAXFMR ELEC 1301996Input1EA8323f493f322-a1b1-4daa-ba34-9144e6e198b4MHMV015181V48M28T33KJ96 D0217300KVAWESTINGHOUSE ELECTRIC CORP.ELEC 1303213aae9-f03e-4b58-8a10-13b665e61adf
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 100 amp, NQODINT PNLBRD MAIN 111997Input1EA821832708abc-cbec-44a7-b082-26b08adbd934MHMV018357PRL-2A1C96646G02WESTINGHOUSE ELECTRIC CORP.ELEC 130eaf3e774-ae33-413a-a6f8-a263dfea047b
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 100 amp, NQODINT PNLBRD MAIN 131988Input1EA821888cf556b-e7c8-4554-aa30-9d25faeae21dMHMV033264PANELBOARDPRL15158C03G02120/208 V, 100AWESTINGHOUSE ELECTRIC CORP.1988ROOM 12158fbba2e-5847-44a3-955d-886d69a40561
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 100 amp, NQODINT PNLBRD MAIN 81996Input1EA8218cb11540c-eccf-46b6-bccd-e12e1d178714MHMV018347PANELBOARDPRL15158C03G02100 AWESTINGHOUSE ELECTRIC CORP.1996ELEC 13098be6616-8410-478d-886d-ae8ff7c1f933
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 225 amp, NQODINT PNLBRD MAIN 11997Input1EA82185309900d-83b5-4afa-82e1-fb7b43a26f84MHMV015176PRL1HAQ32627225A, 208Y120VWESTINGHOUSE ELECTRIC CORP.6/30/1997ELEC 13083c5b36d-53d0-490b-8083-ac1ddf4c3c2e
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 225 amp, NQODINT PNLBRD MAIN 121988Input1EA8218a9b4a940-0be2-4429-a2a9-46531c3a9114MHMV033265PANELBOARDPRL-15158C04G01208/120 V, 225AWESTINGHOUSE ELECTRIC CORP.1988ROOM 1216daa65a2-995b-45d7-9dea-82fda66dc78c
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 225 amp, NQODINT PNLBRD MAIN 161997Input1EA8218e261ef58-8412-4e1d-9ec9-55e08ced8f9fMHMV013017PRL1HAQ32627225A, 208Y120VWESTINGHOUSE ELECTRIC CORP.6/26/1997RM 145e261ef58-8412-4e1d-9ec9-55e08ced8f9f
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 225 amp, NQODINT PNLBRD MAIN 171997Input1EA8218e8cd5fc3-1f09-4f90-86b6-fe70857e9db5MHMV013015PRL1HAQ32627225A, 208Y120VWESTINGHOUSE ELECTRIC CORP.6/26/1997RM 1459c6aee44-eae0-48e3-a305-f26f46ca73de
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 225 amp, NQODINT PNLBRD MAIN 21997Input1EA82187484d6ac-d9df-4d7c-ac94-a8b36197da78MHMV015177PRL1HAQ32627225A, 208Y120VWESTINGHOUSE ELECTRIC CORP.6/30/1997ELEC 1307484d6ac-d9df-4d7c-ac94-a8b36197da78
MHMVKirtland AFBKIRTLAND SITE # 120245HQ GROUP456690D50 ELECTRICALD5010 ELECTRICAL SERVICE & DISTRIBUTIOND501004 PANELBOARDSMain lugs, 120/208 V, 225 amp, NQODINT PNLBRD MAIN 31996Input1EA82187b6f2718-f9ff-4e38-9539-8673bcd65708MHMV015178PRL1HAQ12943 006225A, 208Y120VWESTINGHOUSE ELECTRIC CORP.7/1/1996ELEC 1307b6f2718-f9ff-4e38-9539-8673bcd65708

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .