DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEEV)
HILL AIR FORCE BASE, UTAH
31 March 2009
MEMORANDUM FOR: 775th CES (Mr. Al Lewis)
FROM: 75th CES/CEOHA
SUBJECT: Lead Based Paint (LBP) Survey, Building 2013 (WO #49980). Renovate the facility.
1. On 25 February 2009, Neldon Anderson (Utah LBP Certification #PB-1072) tested the components of Building 2013. Building 2013 was constructed in 1942. A Niton XLp300A XRF Analyzer (Serial # 8413) was used to test the painted surfaces of these components. Please refer to specific results of our survey; see attachment 1.
2. The table below summarizes the building components located in Building 2013 that tested positive for LBP. These components should be segregated or abated prior to renovation or demolition, and a composite TCLP taken of the waste before disposal.
(See attached results for further detail).
Component Color Lead Read Condition
The metal door jamb in the support office.
Tan 9.9 Good
The metal door jamb in the MIC. Gray 5.8 Good
The structural steel in the southwest corner of gear box repair.
Cream 4.2 Good
The structural steel in the southeast corner of room 17.
White 3.3 Good
The ceramic tile in the men’s restroom. White 7.8 Good
The metal door jamb in room 17. Tan 6.9 Good
3. The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, vanish, stain, or other applied coating that has 1mg/cm2 as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000ug/g by dry weight) by laboratory analysis, or more of lead. All other components tested were less than 1 mg/cm2.
4. Any effort to disturb lead paint can create lead dust. Please ensure that appropriate abatement, cleanup, and disposal will be accomplished and that the appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions please feel free to call Troye Davis at 586-7094.
Bldg 2013
Renovate Facility
WO #49980
//original signed// Neldon Anderson 75th Civil Engineering Squadron Maintenance Engineering Certified LBP Inspector Utah Certification #PB-1072