Building: 2013 Inspector: Neldon Anderson
Date: 25-Feb-08 Insp. Number: PB-1072
Time: 1:16 PM
Work Order: 49980 Niton: XLp300A XRF Analyzer
Serial # 8413
XL Number Room Side Structure Condition Substrate Color PbL(mg/cm2) PbL (+/-)
Pre Calibration Cal. Standard
361 0 < 0.01
362 0.28 0.31 +/- 0.02
363 0.9 1.04 +/- 0.06
364 1.4 1.53 +/- 0.09
365 3.3 3.58 +/- 0.39
366 Support office North Door slab Good Metal Tan 0 NEG
367 Support office North Door jamb Good Metal Tan 9.9 POS
368 Support office West Wall Good Drywall Cream 0 NEG
369 Hallway Northwest Wall Good Block Cream 0.03 NEG
370 MIC South Door slab Good Wood Varnish 0 NEG
371 MIC South Door jamb Good Wood Varnish 0 NEG
372 MIC West Door channel Good Metal Gray 0.02 NEG
373 MIC West Rollup door Good Metal Gray 0.01 NEG
374 MIC South Door slab Good Metal Gray 0 NEG
375 MIC South Door jamb Good Metal Gray 5.8 POS
376 Gear box repair North Wall Good Concrete Blue 0 NEG
377 Gear box repair South Wall Good Drywall White 0 NEG
378 Gear box repair Southwest Structural steel Good Metal Cream 4.2 POS
379 Center hallway Center Door slab Good Metal Tan 0 NEG
380 Center hallway Center Door jamb Good Metal Gray 0 NEG
381 Center hallway Center Chair rail Good Wood Varnish 0.35 NEG
382 Center hallway Center Wall Good Drywall Cream 0.02 NEG
383 Center hallway Center Wall Good Drywall Tan 0 NEG
384 East hallway Center Wall Good Block Tan 0 NEG