This is a technical specification for wire mesh partitions at Tinker Air Force Base, Oklahoma, issued in April 2019.
The specification establishes requirements for two types of wire mesh partitions: normal duty for standard industrial use and heavy duty for extra-heavy industrial use. Normal duty partitions utilize 10-gauge wire with 1-1/2 inch mesh, while heavy duty partitions use 6-gauge wire with 2-inch mesh. Both types must include vertical and horizontal frames, corner posts, line posts, hinged or sliding doors with mortise-type locks, and service windows. All ferrous metal components must contain a minimum of 15 percent post-consumer recycled content, and wire materials must contain a minimum of 50 percent post-industrial recycled content. Material specifications reference ASTM A36/A36M for carbon structural steel and AISI SG03-3 for cold-formed steel. Fabrication requires wire to be woven into diamond mesh with intermediate crimping, securely clinched to frames with mortised and tenoned joints. All components must be thoroughly cleaned, phosphate-treated, and painted with gray enamel in the shop. Installation must be plumb, level, and true to line within a tolerance of 1/8 inch in 10 feet, with floor sockets anchored using expansion bolts and vertical frames bolted together at specified intervals. Free-standing partitions exceeding 20 feet in length require bracing connected to capping bars or anchored base plates with expansion bolts.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019
SECTI ON 10 22 13
WI RE MESH PARTI TI ONS
04/17
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
AMERI CAN I RON AND STEEL I NSTI TUTE ( AI SI )
AI SI SG03- 3 ( 2002; Suppl 2001- 2004; R 2008) Col d- For med St eel Desi gn Manual Set
ASTM I NTERNATI ONAL ( ASTM)
ASTM A36/ A36M ( 2014) St andar d Speci f i cat i on f or Car bon St r uct ur al St eel
1. 2 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00
SUBMI TTAL PROCEDURES:
SD- 02 Shop Dr awi ngs
Wi r e Mesh Par t i t i ons
Show l ayout , det ai l s, mat er i al s, di mensi ons, f i ni shes, and al l i nf or mat i on necessar y f or f abr i cat i on and i nst al l at i on.
SD- 03 Pr oduct Dat a
Wi r e Mesh Par t i t i ons
Submi t f or each t ype of par t i t i on, door , and wi ndow.
1. 3 DELI VERY, STORAGE, AND HANDLI NG
Del i ver mat er i al s i n manuf act ur er ' s or i gi nal , unopened cont ai ner s or packagi ng wi t h l abel s i nt act and l egi bl e. Del i ver , st or e, and handl e mat er i al s so as t o pr event damage. Repl ace damaged or def ect i ve mat er i al s wi t h new.
1. 4 DESCRI PTI ON OF WORK
Wi r e mesh par t i t i ons must be al l wi r e t ype or sheet met al base t ype, nor mal dut y f or nor mal i ndust r i al use, heavy dut y f or ext r a heavy i ndust r i al use. Pr ovi de par t i t i ons compl et e wi t h f ast ener s, cappi ng bar s, adj ust abl e f l oor socket s, br aci ng, door s, har dwar e, and ot her i t ems necessar y f or a compl et e, useabl e, and r i gi d i nst al l at i on.
Apr i l 2019 Page 1 SECTI ON 10 22 13
PART 2 PRODUCTS
2. 1 PRODUCT SUSTAI NABI LI TY CRI TERI A
For pr oduct s i n t hi s sect i on, wher e appl i cabl e and t o ext ent al l owed by per f or mance cr i t er i a, pr ovi de and document t he f ol l owi ng:
2. 2 MATERIALS
Met al post and f r ami ng mat er i al s l i s t ed bel ow must cont ai n a mi ni mum of 15 per cent post - consumer r ecycl ed cont ent and wi r e mat er i al s must cont ai n a mi ni mum of 50 per cent post - i ndust r i al r ecycl ed cont ent . Pr ovi de dat a i dent i f y i ng per cent age of r ecycl ed cont ent f or met al post and f r ami ng mat er i al s. Al so pr ovi de dat a i dent i f y i ng per cent age of r ecycl ed cont ent f or wi r e mat er i al s.
2. 2. 1 St eel Shapes, Pl at es, and Bar s
ASTM A36/ A36M.
2. 2. 2 Col d- For med St eel
AI SI SG03- 3.
2. 2. 3 Wi r e Mesh
Car bon st eel wi r e, woven di amond mesh, i nt er medi at e cr i mped.
2. 2. 4 Fl oor Socket s
Cast or f or ged st eel or duct i l e i r on, adj ust abl e, appr oxi mat el y 2- 1/ 2 i nches hi gh.
2. 3 NORMAL DUTY PARTI TI ONS
2. 3. 1 Wi r e Mesh
10 gage wi r e, 1- 1/ 2 i nch mesh.
2. 3. 2 Ver t i cal Fr ames
1- 1/ 4 by 5/ 8 i nch col d- r ol l ed C sect i on channel s or 1- 1/ 4 by 5/ 8 by 1/ 8 i nch channel s. Pr ovi de onl y C channel s wher e f r ames ar e i nst al l ed t oe t o t oe wi t hout post s.
2. 3. 3 Hor i zont al Fr ames
1 by 5/ 8 i nch channel s.
2. 3. 4 Cent er Rei nf or ci ng Bar
One 1 by 1/ 2 by 1/ 8 i nch channel wi t h al l wi r es woven t hr ough, or t wo 1 by 3/ 8 by 1/ 8 i nch channel s bol t ed t oget her wi t h mesh i n bet ween.
2. 3. 5 Cappi ng Bar
2- 1/ 4 by one by 1/ 8 i nch channel or 2 by 1/ 4 i nch f l at bar .
Apr i l 2019 Page 2 SECTI ON 10 22 13
2. 3. 6 Cor ner Post s
St r uct ur al st eel angl es, 1- 1/ 4 by 1- 1/ 4 by 1/ 8 i nch.
2. 3. 7 Li ne Post s
Unl ess ot her wi se i ndi cat ed, pr ovi de par t i t i ons mor e t han 12 f eet hi gh wi t h f l at bar l i ne post s bol t ed bet ween ver t i cal f r ame channel s. Si zes of post s must be as f ol l ows:
Par t i t i on Hei ght Si ze of Post s
12 f eet t o 14 f eet 8 i nches 1- 3/ 4 by 5/ 16 i nch or 2 by 1/ 4 i nch
14 f eet 8 i nches t o 19 f eet 8 i nches 2- 1/ 2 by 5/ 16 i nch
19 f eet 8 i nches t o 23 f eet 8 i nches 3 by 5/ 16 i nch
2. 3. 8 Hi nged Door s
Fr ames must be 1- 1/ 4 by 1/ 2 by 1/ 8 i nch channel s wi t h 1- 1/ 4 by 1/ 8 i nch f l at bar cover on t op and bot t om r ai l s and on hi nge st i l e and a 1- 3/ 8 by 3/ 4 by 1/ 8 i nch angl e r i vet ed t o t he l ock st i l e. Pr ovi de 1 1/ 2 pai r s of r egul ar wei ght , wr ought st eel , non- r emovabl e pi n, but t hi nges r i vet ed or wel ded t o t he door and t he door openi ng f r ame f or each door .
2. 3. 9 Sheet Met al Base
Hot - or col d- r ol l ed sheet st eel , not l i ght er t han 16 gage.
2. 4 HEAVY DUTY PARTI TI ONS
2. 4. 1 Wi r e Mesh
6 gage wi r e, 2 i nch mesh.
2. 4. 2 Panel Fr ames
1- 1/ 2 by 3/ 4 by 1/ 8 i nch st eel channel s.
2. 4. 3 Cent er Rei nf or ci ng Bar
One 1- 1/ 2 by 3/ 4 by 1/ 8 i nch channel wi t h al l wi r es woven t hr ough, or t wo 1- 1/ 4 by 3/ 8 by 1/ 8 i nch channel s bol t ed t oget her wi t h mesh i n bet ween.
2. 4. 4 Cappi ng Bar
St r uct ur al st eel channel , 3 i nch by 4. 1 pounds.
2. 4. 5 Cor ner Post s
St r uct ur al st eel angl es, 1- 3/ 4 by 1- 3/ 4 by 1/ 8 i nch.
2. 4. 6 Li ne Post s
Unl ess ot her wi se i ndi cat ed, pr ovi de par t i t i ons wi t h f l at bar l i ne post s bol t ed bet ween ver t i cal f r ame channel s. Si zes of post s must be as f ol l ows:
Apr i l 2019 Page 3 SECTI ON 10 22 13
Par t i t i on Hei ght Si ze of Post s
7 f eet t o 12 f eet 2- 1/ 2 by 5/ 16 i nch
12 f eet t o 16 f eet 3 by 5/ 16 i nch or 2- 1/ 2 by 3/ 8 i nch
16 f eet t o 20 f eet 3- 1/ 2 by 5/ 16 i nch
2. 4. 7 Hi nged Door s
Fr ames must be 1- 1/ 2 by 3/ 4 by 1/ 8 i nch channel s wi t h 1- 1/ 2 by 1/ 8 i nch f l at bar cover on t op and bot t om r ai l s and on hi nge st i l e and a 1- 5/ 8 by 7/ 8 by 1/ 8 i nch angl e r i vet ed t o t he l ock st i l e. Pr ovi de 1- 1/ 2 pai r s of heavywei ght , wr ought st eel , non- r emovabl e pi n, but t hi nges r i vet ed or wel ded t o t he door and t he door openi ng f r ame f or each door .
2. 5 SLI DI NG DOORS
Fr ames must be 1- 1/ 2 by 3/ 4 by 1/ 8 i nch channel s wi t h 1- 1/ 2 by 1/ 8 i nch f l at bar cover al l ar ound. Pr ovi de t wo f our - wheel , r ol l er bear i ng hanger s and st eel box t r ack f or each door .
2. 6 DOOR OPENI NG FRAMES
Pr ovi de f r ames t he same si ze and shape as t he ver t i cal f r ames f or t he mesh panels.
2. 7 LOCKS
Pr ovi de each door wi t h a mor t i se t ype l ock wi t h a s i x- pi n t umbl er l ock cyl i nder on t he out si de and a r ecessed knob on t he i nsi de.
2. 8 SERVI CE WI NDOWS
Sl i de up t ype, mount ed i n st andar d mesh panel r ei nf or ced wi t h channel t r acks. Openi ng must be 24 i nches wi de by 15 i nches hi gh unl ess ot her wi se i ndi cat ed. Pr ovi de t wo spr i ng l oaded l at ches, oper abl e onl y f r om t he i nsi de, t o l ock wi ndow i n open and cl osed posi t i ons. For m shel f of 12 gage sheet st eel , 12 i nches deep by 25 i nches wi de, unl ess ot her wi se indicated.
2. 9 FABRICATION
2. 9. 1 St andar d Panel s
Wi r e must be woven i nt o di amond mesh, i nt er medi at e cr i mped, and secur el y c l i nched t o f r ames. Joi nt s must be mor t i sed and t enoned. Wi r e must be cont i nuous at cent er r ei nf or ci ng bar s, ei t her woven t hr ough a s i ngl e channel or bol t ed bet ween t wo channel s. Panel ver t i cal f r ames must have 1/ 4 i nch bol t hol es 12 i nches o. c. f or nor mal dut y par t i t i ons; and 3/ 8 i nch bol t hol es 18 i nches o. c. f or heavy dut y par t i t i ons.
2. 9. 2 Sheet Met al Base Panel s
Upper por t i on must be as speci f i ed f or st andar d panel s, except t hat t he wi r e must be cl i nched i nt o t he cent er r ei nf or ci ng bar . For m sheet st eel t o f i t bet ween t he panel f r ames and secur el y bol t t o t he f r ames.
Apr i l 2019 Page 4 SECTI ON 10 22 13
2. 9. 3 Door s and Ser vi ce Wi ndows
Const r uct i on must be si mi l ar t o t hat speci f i ed f or panel s. Wi r e mesh must be t he same as t hat used i n t he adj acent par t i t i on panel s.
2. 9. 4 Finish
Thor oughl y c l ean f er r ous met al , t r eat wi t h phosphat e, and pai nt wi t h gr ay enamel i n t he shop.
PART 3 EXECUTI ON
3. 1 INSTALLATION
3. 1. 1 Wi r e Mesh Par t i t i ons
I nst al l pl umb, l evel , and t r ue t o l i ne, wi t hi n a t ol er ance of 1/ 8 i nch i n 10 f eet or t he hei ght or r un of t he par t i t i on, i f l ess t han 10 f eet .
Anchor f l oor socket s t o t he f l oor wi t h expansi on bol t s. Bol t ver t i cal f r ames and post s t oget her wi t h 1/ 4 i nch bol t s 12 i nches o. c. f or nor mal dut y par t i t i ons; and 3/ 8 i nch bol t s 18 i nches o. c. f or heavy dut y par t i t i ons. Secur e t op f r ames t o a cont i nuous cappi ng bar wi t h 1/ 4 i nch di amet er U bol t s not mor e t han 28 i nches o. c.
3. 1. 2 Door s and Ser vi ce Wi ndows
I nst al l i n accor dance wi t h t he manuf act ur er s ' r ecommendat i ons. Adj ust as r equi r ed so t hat door s , wi ndows, and har dwar e oper at e f r eel y and pr oper l y.
3. 1. 3 Bracing
Br ace f r ee st andi ng par t i t i ons mor e t han 20 f eet i n l engt h, at i nt er val s not gr eat er t han 20 f eet wi t h a st eel channel br ace connect ed t o t he cappi ng bar and anchor ed t o t he bui l di ng wal l or f r ami ng member ; wi t h a st r uct ur al st eel I sect i on or t ube post wel ded t o a 9 by 9 i nch st eel base pl at e anchor ed t o t he f l oor wi t h 4 expansi on bol t s; or as i ndi cat ed.
3. 1. 4 Touch-Up
Cl ean and pai nt scr at ches, abr asi ons, and ot her damage t o shop pai nt ed sur f aces t o mat ch t he shop- appl i ed f i ni sh.
Repai r mi nor sur f ace r ust ar eas. Cl ean and pr i me wi t h r ust i nhi bi t i ve pr i mer pai nt . Appl y f i nal pai nt t o mat ch shop- appl i ed f i ni shes.
- - End of Sect i on - -