12. Drawing MD601-REV1.pdf

PDF 289 KB Posted

Attached to
RPR/ADD RADR VEHICLE MX, B121 Federal contract opportunity
Solicitation number
FA557525B0008
Issued by
Department of the Air Force United States Air Forces in Europe - Air Forces Africa

About this file

This technical drawing is a detailed mechanical piping flow diagram (MD601 Revision 1) for the 496th Air Base Squadron, showing the existing condition and demolition plan for water treatment and HVAC system piping. The diagram includes multiple pipe connections, valves, pumps, and equipment with various pipe sizes ranging from 1/2" to 6", and includes multiple water storage tanks (including a 1500-liter tank). The drawing features a comprehensive legend of pipe fittings and symbols, including filters, control valves, shut-off valves, pressure gauges, thermometers, and pumps. The document is dated July 4th, 2025, and is part of a mechanical system documentation set for a project at Moron Air Base in Spain, specifically related to the QUUG 23-1001 project for radar vehicle maintenance infrastructure.

View the file

Other files for this federal contract opportunity

Other files attached to RPR/ADD RADR VEHICLE MX, B121, newest first.
File Type Posted
MFR QUUG 23-1001 Questions and Answers.pdf PDF
Solicitation Amendment FA557525B00080002 SF 30.pdf PDF
5b. Schedule of Materials (Spa) REV1.xlsx XLSX spreadsheet
10. HVAC AIR DISTRIBUTION REV1.pdf PDF
13. Drawing MH601-REV1.pdf PDF
14. Drawing MP601-REV1.pdf PDF
4. Cost Estimated Blank REV1.xlsx XLSX spreadsheet
6. SCOPE OF WORK AND DRAWINGS REV1.pdf PDF
8. SPECIAL CONDITIONS REV1.pdf PDF
9. CONDICIONES ESPECIALES REV1.pdf PDF
11. DISTRIBUCIÓN DE AIRE HVAC REV1.pdf PDF
5a. Schedule of Materials (Eng) REV1.xlsx XLSX spreadsheet
7. ALCANCE DE LOS TRABAJOS Y PLANOS REV1.pdf PDF
Solicitation Amendment FA557525B00080001 SF 30.pdf PDF
3-Specifications (Spa) QUUG 23-1001.pdf PDF
2-Specifications (Eng) QUUG 23-1001.pdf PDF
4-Cost Estimated Blank QUUG 23-1001.xlsx XLSX spreadsheet
5B-Schedule of Materials (Spa).xlsx XLSX spreadsheet
Solicitation - FA557525B0008.pdf PDF
5A-Schedule of Materials (Eng).xlsx XLSX spreadsheet
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPOSITO DE TRATAMIENTO DE AGUA

MAS CERCANO (TIPICO).

LLEVAR AL SUMIDERO

CO

LE

CT

OR

D E

SU

MI

NI

ST

RO

DE LAS CLIMATIZADORAS

A LAS CLIMATIZADORAS

CO

LE

CT

OR

D E

RE

TO

RN

O

100 LITROS

100 LITROS

50 LITROS

1500 LITROS

CONTINUA A PISO SUPERIOR

WATER TREATMENT TANK

HWS

LL P-3

HLT

TS-1 FS

FOS

LLT

ACWCH

FOR

B-2

CHWR

FLOOR DRAIN (TYPICAL)

RUN TO THE NEAREST

2"

2"

CHWS

FS

HWR

V2

V1

S

CHOS

W

1-1/2"

3/4"

P-7

FOS

FOR

ET-3

HLT

T

P

P

B-1

T

ET-2 HLT

1-1/2"

1-1/2"

HWS

1-1/2"

FS

LL HW

R

2"

HWS

HW

R

P-2

1-1/2"

SU

PP

LY

H

EA

DE

R

P-6

P-4

2"

HW

R

1-1/2"

2"

HWR

3/8"

CHWR/HWR

2"

V3 V4

P-1

P-1

ET-1

TC

HE-2 TS

CHWS/HWS

2"

2"

TC TS

HE-1

P-8 1-1/4"

DHWT

1-1/4"

P-9

1/2"

CW

DHWR

DHWS

HWR FROM THE AHU

2"

3/4"

1-1/4" 1-1/4"

1500 LITERS

1-1/4"

1-1/4"

1-1/4"

3/8"

HWS

P-5

2"

TO THE AHU

3/4"

RE

TU

RN

H

EA

DE

R

4"

6"

6"

1"

3/4"

100 LITERS

100 LITERS

1/2"

3/4"

50 LITERS

M.A.V.

FC

M.A.V.

FC

CONTINUES TO UPPER FLOOR

1"

3/4"

1"

3/4"

3/4" R-1

R-2

R-3

3/8"

T M

M

M

M

M M

T

T

M

M

M

M

M

: 3

MD601

REV-1

144 183

R -8

- 1

M

D

M

EC

H

AN

IC

AL

. P

IP

IN

G

F

LO

W D

IA

G

R

AM

. E

XI

ST

IN

G C

O N

D

IT

IO

N

A N

D D

EM

O

LI

TI

O N

D E

M O

LI

C

IÓ

N

(R E

V -1

0%

JU

L

4T H

, 2

#1

ESCALA

SCALE NTS

DIAGRAMA DE FLUJO DE TUBERÍAS. ESTADO EXISTENTE Y DEMOLICIÓN

PIPING FLOW DIAGRAM. EXISTING CONDITION AND DEMOLITION

SÍMBOLO

SYMBOL

DESCRIPCIÓN

DESCRIPTION

FILTRO

STRAINER

VÁLVULA DE CONTROL DE 3 VIAS

3-WAY CONTROL VALVE

VÁLVULA DE CORTE

SHUT OFF VALVE

VÁLVULA DE EQUILIBRADO MANUAL

MANUAL BALANCING VALVE

LEYENDA DE ACCESORIOS DE TUBERÍAS

PIPE FITTINGS LEGEND

SUMIDERO DE EMBUDO

FUNNEL DRAIN

FILTRO DE ACEITE

OIL FILTER

MANÓMETRO

PRESSURE GAUGE

TERMOMETRO

THERMOMETER

BOMBA

PUMP

VÁLVULA DE SEGURIDAD

SAFETY VALVE

VÁLVULA TERMOESTÁTICA

THERMOSTATIC VALVE

VÁLVULA DE CONTROL DE 2 VIAS

2-WAY CONTROL VALVE

SUPRESOR DE CONTRAFLUJO

BACKFLOW PREVENTER

WE PROJ ECT A IR POWER

6T

H AIR BASE SQUADRON

M

T

M

M E

C Á

N

IC

A . D

IA

G

R A

M A

D E

F

LU

JO

D

E T

U B

E R

ÍA

S

E

S

TA

D O

E X

IS

TE

N

TE

Y D

E M

O

LI

C

IÓ

N (R

E V

-1

AutoCAD SHX Text

PROJECT QUUG 23-1001

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

REPARAR/AMPLIAR EDIFICIO DE MANTENIMIENTO DE

AutoCAD SHX Text

SHEET NUMBER:

AutoCAD SHX Text

BASE CIVIL ENGINEERING

AutoCAD SHX Text

MORÓN AIR BASE - SPAIN

AutoCAD SHX Text

496 AIR BASE SQUADRON (USAFE)

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

REVISION:

AutoCAD SHX Text

FACILTY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DRAWING NO:

AutoCAD SHX Text

ORIGINAL FORMAT:

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text

AutoCAD SHX Text H

AutoCAD SHX Text B

AutoCAD SHX Text

VEHÍCULOS RADR, B121

AutoCAD SHX Text

DOR:

AutoCAD SHX Text

ENGINEER/ARCHITE.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

JOSÉ MANUEL RODRÍGUEZ

AutoCAD SHX Text

GONZALO TEJEDOR

AutoCAD SHX Text

JJ. TEJEDOR

AutoCAD SHX Text

JMRM:

AutoCAD SHX Text

GTP:

AutoCAD SHX Text

R.IZQUIERDO

AutoCAD SHX Text

J. CURTIDO

AutoCAD SHX Text

A.PEREZ

AutoCAD SHX Text

G. DORTA

AutoCAD SHX Text

EDI RPR/ADD RADR VEHICLE MX, B121

AutoCAD SHX Text

J. NEVA / M. IGLESIAS

AutoCAD SHX Text

ENFRIADORA DE AGUA EXISTENTE SOBRE LA CUBIERTA

AutoCAD SHX Text

EXISTING CHILLER MOUNTED ON THE ROOF

AutoCAD SHX Text

ENFRIADORA DE AGUA EXISTENTE SOBRE LA CUBIERTA. MODELO 30RAN015-513

AutoCAD SHX Text

EXISTING CHILLER MOUNTED ON THE ROOF. MODEL 30RAN015-513MODEL 30RAN015-513

Sheets and Views
Layout1

File details come from the government source that posted it. Updated .