This is an Asbestos Containing Materials (ACM) and Lead-Based Paint (LBP) survey document for Building 13140 (Thor Dormitory) at Vandenberg Space Force Base, California. The survey provides detailed findings on the presence and location of ACM and LBP within the building, which contractors must address during the demolition project. The survey identifies specific areas where ACM and LBP are present, their condition, and the quantities requiring removal and proper disposal in accordance with federal environmental regulations.
The survey results are critical to the demolition RFQ (Solicitation Number FA461026Q1314) as they inform contractors of the scope and complexity of hazardous materials handling required. Contractors must incorporate survey findings into their cost estimates and project schedules, as all identified ACM and LBP must be removed and properly disposed of prior to and during the demolition of Building 13140 and removal of support equipment from Building 13143. The final quote due date is Friday, June 26, 2026, no later than 2:00 PM PDT, with quotes valid for a minimum of 120 calendar days from the submission deadline. Interested vendors requiring additional structural drawings should contact Chase French at chase.french@spaceforce.mil.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX B-44
Asbestos Survey Summary for
Building 13140B Vandenberg AFB, California
Bureau Veritas Project # 25009-009558.00
Surveyed by: Mr. Richard McKenna, CAC (Certification No. 92-0683)
Dates of Survey: January 25, 2011
Number of Samples collected: Sixty-three (63)
Number of Samples Analyzed by PLM: Fifty-seven (57)
Number of Samples Analyzed by TEM: Four (4)
Number of Samples Analyzed by PLM Point Count: Ten (10)
Photos of Sample Locations: Refer to Appendix C (separated per building), for Photos of Sample Locations on Compact Disc (CD).
Building Description:
Building 13140B at Vandenberg AFB, California is a three-story, concrete structure constructed in 1976 that comprises approximately 25,904 square feet of floor space.
The interior spaces of Building 13140B included living quarters, restrooms, lounges and laundry rooms. The interior walls were finished with painted gypsum board, ceramic tile. The interior ceilings were finished with spray applied acoustical material, or ceiling tiles. Interior floor finishes included glued on carpet, ceramic tile, and vinyl floor tile. Additional interior finishes included vinyl cove base. The heating, ventilating, and air conditioning (HVAC) system supplied air to each room via insulated ductwork. The piping was also insulated. The building’s roof was flat and consisted of built-up black tar and paper. Note that due to the non-destructive nature of this assessment, the aforementioned ceiling tiles with associated mastic and cementitous panels were not sampled.
Survey Results
One (1) of the building materials sampled was found to contain asbestos greater than one percent and two (2) materials were assumed to contain asbestos greater than one percent. The following table presents a summary of our findings by homogenous sampling area (HA). Sample and asbestos location drawings are attached at the end of Appendix B-44. The laboratory results and the field chain of custodies are also attached at the end of Appendix B-44.
Building 13140B (continued)
Table 2: Asbestos Assessment Results
Vandenberg AFB, California
Material (Classification) Location of Material
Condition
Friable Yes/No
Quantity
(NESHAP
Category)
Asbestos Content
HA-1: Gypsum board and associated joint compound (M) Throughout building Good Yes 50,000 s.f.
(NA)
Gypsum board: ND Joint compound: 0.50% chrysotile2
HA-2: Texture coat (S) Throughout building Good Yes 50,000 s.f.
(NA)
Texture coat: 0.50% chrysotile2
HA-3: Yellow, green and brown mastics accosted with red carpet (M)
Throughout building Good No 20,000 s.f.
(NA)
Yellow mastic: ND Green mastic: ND Brown mastic: ND
HA-4: 4” brown cove base and associated brown mastic(M) Throughout building Good No 4,000 l.f.
(NA)
Cove base: ND
Mastic: ND
HA-5: 4” brown cove base and brown mastic (M)
Restrooms throughout building Good No 500 l.f.
(NA)
Cove base: ND Mastic: ND
Mineral mixture: 0.30% chrysotile2
HA-6: White/silver paper wrap on fiberglass pipe run insulation and associated tan and clear mastics (TSI)
Throughout building Good Yes 1,500 l.f.
(NA)
Wrap: ND Tan mastic: ND
Clear mastic: ND
HA-7: White grout associated with 4” ceramic wall tile grout (M)
Restrooms throughout building Good No 6,000 s.f.
(NA) ND
HA-8: Gray and white grouts associated with 1” beige ceramic floor tile (M)
Restrooms throughout building Good No 2,500 s.f.
(NA)
Gray grout: ND White grout: ND
HA-9: Spray applied acoustic ceiling material (S)
Rooms throughout building Good Yes 12,000 s.f.
(NA) ND
HA-10: 12” x 12” gray vinyl floor tile with associated tan mastic (M)
Closets throughout building Good No 400 s.f.
(NA)
Floor tile: ND1
Mastic: ND
HA-11: 12” x 12” gray vinyl floor tile with associated black, cream, and tan mastics and white mineral mixture underneath carpet (M)
Hallways, closets and lounges throughout building Good No 4,000 s.f.
(Cat. I)
Floor tile: 3% chrysotile Black mastic: 3% chrysotile Cream mastic: ND
Tan mastic: ND Mineral mixture: ND
HA-12: Beige grout associated with 6” beige ceramic tile (M) Laundry room Good No 250 s.f.
(NA) ND
HA-13: Black/white roofing penetration mastic (M) Roof Good No 50 s.f.
(NA) ND1
HA-14: Silver/gray duct sealant
(M) Roof HVAC units Good No 80 l.f.
(NA)
Silver paint: ND
Gray sealant: ND
HA-15: Texture coat (S) Exterior CMU walls Good Yes 15,000 s.f.
(NA) ND
Table 2: Asbestos Assessment Results
Vandenberg AFB, California
Material (Classification) Location of Material
Condition
Friable Yes/No
Quantity
(NESHAP
Category)
Asbestos Content
HA-16: Mineralized black/gray cap sheet and associated black tar, beige insulation and yellow foam (M)
Roof Good No 8,000 s.f.
(NA) All layers: ND1
HA-16: Black/gray roof penetration mastic( M) Roof penetrations Good Yes 50 s.f.
(NA) ND1
HA-17: Cementitious paneling (M)
Exterior under windows Good No NQ
(Cat. II) Assumed to contain asbestos greater than one (1) percent
HA-18: 1’x 1’ ceiling tiles and mastic (M) Lounge Good No
NQ
(RACM and
Cat. II)
Assumed to contain asbestos greater than one (1) percent s.f. = Square Feet, l.f. = Linear Feet, ND = Non Detect, M = Miscellaneous, S = Surfacing Material, Cat. I = Category I Non-Friable Asbestos Containing Material, Cat. II = Category II Non-Friable Asbestos Containing Material, 1 = Verified by TEM Analysis, 2 = Verified by PLM Point Count Analysis, NQ = Not Quantified, and NA = Not Applicable
Prepared by: Reviewed by:
Timothy J. Coe, CAC Michael-Ray Boyden, CAC Certified Asbestos Consultant (05-3838) Certified Asbestos Consultant (93-0985) Health, Safety and Environmental Services Health, Safety and Environmental Services
Attachments:
• Laboratory Report and Field Chain of Custody Forms
• Figure 1 – Sample Location Drawing
• Figure 2 – Asbestos Location Drawing
LABORATORY REPORT AND FIELD CHAIN OF CUSTODY FORMS
Bureau Veritas North America, Inc.
Health, Safety, and Environmental Services 3380 Chastain Meadows Parkway, Suite 300 Kennesaw, GA 30144
Main: (770) 499-7701 Fax: (770) 499-7511 www.us.bureauveritas.com
February 14, 2011
BUREAU VERITAS - PLEASANTON
Michael-Ray Boyden
Dear Michael-Ray Boyden:
Reference: 25009-009558.00/300-VANDENBERG AFB (BLDG 13140)
Bureau Veritas Work Order No.:A1102024
2430 Camino Ramon
San Ramon, CA 94583- Suite 122
Bureau Veritas North America, Inc. received 57 samples on 1/31/2011 and reported on 2/14/2011 1:46:07 PM for the analyses presented in the following report.
The results apply only to the samples analyzed in this project. Please note that any unused portion of the samples will be discarded after a thirty-day holding period, unless you have requested otherwise.
We appreciate the opportunity to assist you. If you have any questions concerning the report, please contact the analyst whose name appears on the report or myself at (770) 499-7701.
Sincerely, Alan M. Segrave, P.G.
Director, Laboratory Services http://www.us.bureauveritas.com
14-Feb-11Date:CASE NARRATIVE
Project: 25009-009558.00/300-VANDENBERG AFB (BLDG 13140)
CLIENT: BUREAU VERITAS - PLEASANTON
Work Order No A1102024 Report Date: 14-Feb-11
ANALYTICAL METHOD FOR ASBESTOS IN BULK SAMPLES USING POLARIZED
LIGHT MICROSCOPY (PLM)
The results of this report relate only to the samples listed in the body of this report.
Unless otherwise noted below, the following statements apply: 1) all samples were received in acceptable condition, 2) all quality control results associated with this sample set were within acceptable limits and/or do not adversely affect the reported results, and 3) the industrial hygiene results have not been blank corrected unless otherwise noted.
Use of EPA/600/R-93/116 satisfies applicable requirements of the USEPA's "Interim Method for the Determination of Asbestos in Bulk Insulation Sample", EPA-600/M4-82-020, December 1982, published as Appendix E to Subpart E of 40CFR763. Bulk samples analyzed by New York State methods follow stratified point counting methods (198.1) or Method 198.6 for PLM non-friable organically bound materials (NYSDOH Lab Code –11645). Percentages are visual estimations of asbestos >10:1 aspect ratio. The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples for which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
NESHAP requires point counting of a bulk sample when the result is <10% by a method other than point counting. EPA, however states that if 3 mounts of the sample are analyzed and the asbestos percentage is <10% by visual estimation, the client may elect to assume the amount to be greater than 1% or require verification by point counting. If the result by point counting is different than the result obtained by visual estimation, the point count result will be used. Sample friability or non-friability noted on the report is a requirement for the State of California and refers only to the condition of the sample under macroscopic examination. It does not imply friability or non-friability for the sample as collected or observed in the field as determined by the person collecting the sample. The Kennesaw, Georgia lab is accredited by NVLAP –Lab Code 101125-0.
(a)Polarized- light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing. When analysis of such materials by PLM yields results negative for the presence of asbestos, Bureau Veritas recommends utilizing quantitative transmission electron microscopy (TEM). For more information, contact the laboratory.
References McCrone, Walter C. 1980. The Asbestos Particle Atlas. Ann Arbor, MI: Ann Arbor Science
CLIENT: BUREAU VERITAS - PLEASANTON
Work Order No A1102024 Report Date: 14-Feb-11
Publishers, Inc.
United States Environmental Protection Agency. Environmental Monitoring Systems Laboratory.
1982. Interim Method for the Determination of Asbestos in Bulk Insulation Samples. EPA-600/M4-82-
020. Washington: GPO, December.
United States Environmental Protection Agency. Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993 (PLM)
Fed. Reg. Vol. 55, No.224, 11/20/90, p.48415 (NESHAP) EPA Memorandum 5/8/1991 –NESHAP Clarifications
NYSDOH Methods 198.1/198.6
ANALYTICAL METHOD FOR ASBESTOS IN BULK SAMPLES USING POLARIZED
LIGHT MICROSCOPY (PLM) USING POINT COUNTING
A representative portion of the bulk sample is transferred to a small dish. The sample is examined under a stereomicroscope at 10x to 40x magnification to note the physical characteristics of the sample.
A small subsample is extracted and mounted on a microscope slide using a refractive index liquid (Cargille Series E: HD [high dispersion]). The subsample is analyzed by polarized light microscopy supplemented by dispersion staining. Percentage of asbestos is determined using point counting on fibers >10:1 aspect ratio. For point counting, a minimum of four slides are prepared, with 100 non-empty points counted on each of the slides. Bulk samples analyzed by New York State methods follow stratified point counting methods or Method 198.1 for PLM non-organically bound materials (NYDOH Lab Code -11645). Bulk samples analyzed to meet the requirements of the State of California utilize current EPA methods except 1000 points are counted instead of 400 points. All points counted use the center cross-hair reticle procedure. The percentage of asbestos points (identified by central stop dispersion staining) divided by the total points counted yields the percent asbestos. Final results are reported as type of asbestos and percent asbestos.
The Kennesaw, Georgia lab is accredited by NVLAP –Lab Code 101125-0.
References
McCrone, Walter C. 1980. The Asbestos Particle Atlas. Ann Arbor, MI: Ann Arbor Science Publishers, Inc.
Work Order No A1102024 Report Date: 14-Feb-11
United States Environmental Protection Agency. Environmental Monitoring Systems Laboratory.
1982. "Interim Method for the Determination of Asbestos in Bulk Insulation Samples." EPA-600/M4- 82-020. Washington: GPO, December.
Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993
(PLM)
New York ELAP Method 198.1
QUANTITATIVE ANALYSIS OF BULK SAMPLES FOR ASBESTOS USING TRANSMISSION
ELECTRON MICROSCOPY (TEM)
Upon receipt in the laboratory, samples are ground until homogeneous. Each sample is weighed in a tared silica crucible. The sample is placed in a muffle furnace at a temperature of 480C for at least 3 hours or until the weight has stabilized. The sample is allowed to cool to room temperature and immediately weighed to calculate percent organic loss.
Approximately 1 ml of nondiluted HCL acid is slowly added to remove calcite and dolomite from the ashed sample. After evolution of CO2 gas has ceased, the sample is immediately diluted with ultra-pure water. The sample is then dispersed in 50 ml of ultra-pure water and filtered onto a pre-weighed 47 mm,
0.45 um pore size, MCE filter. The filter is dried on a slide warmer and weighed once again.
A 1 cm2 portion of the filter is cut and placed in a clean silica crucible. Approximately 250 ul of both 20 ppm methyl cellulose solution and isopropyl alcohol are added and ultra-sonicated for 1 minute to remove the deposited sample into suspension. Approximately 3 ul of the suspension is pipetted onto a carbon-coated copper TEM grid and allowed to dry.
Grids are examined in the TEM at 15,000X magnification. Asbestos is identified using morphology, selected area electron diffraction, and energy-dispersive x-ray spectroscopy. From TEM examination, a visual area estimation is made of asbestos in the final residue. Percent asbestos in the final residue is then extrapolated using gravimetric records to percent asbestos in the total sample.
The Kennesaw, Georgia lab is accredited by NVLAP –Lab Code 101125-0.
References
Chatfield Method for Quantitative Analysis of Bulk Samples for Asbestos Using Transmission Electron
Work Order No A1102024 Report Date: 14-Feb-11
Microscopy (unpublished).
United States Environmental Protection Agency. Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993 (PLM)
NOTE: Some of the samples may have contained inseparable layers which were combined during preparation.
Work Order No.: A1102024
Client Reference: 25009-009558.00/300-VANDENBERG AFB (BLDG 13140)
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
<1%
Sample Morphology
001A 13140-1A
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 10 Homogeneous White Paint/Joint Compound
Chrysotile Non-Detected Binder/Filler< 1%
(2) 90 Homogeneous White/Brown Drywall None Detected Cellulose fiber Binder/Filler1% Tape
02/04/2011VK
<1%
Sample Morphology
002A 13140-1B
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 20 Homogeneous White Paint/Joint Compound
Chrysotile Non-Detected Binder/Filler< 1%
(2) 10 Homogeneous White Joint Compound/Tape
Chrysotile Non-Detected Binder/Filler< 1%
(3) 70 Homogeneous White/Brown Drywall None Detected Cellulose fiber Binder/Filler1% Tape
02/04/2011VK
<1%
Sample Morphology
003A 13140-1C
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 10 Homogeneous White Joint Compound Chrysotile Non-Detected Binder/Filler< 1%
(2) 20 Homogeneous White Joint
Compound/Tape Chrysotile Non-Detected Binder/Filler< 1%
(3) 70 Homogeneous White/Brown Drywall None Detected Cellulose fiber Binder/Filler1% Tape
02/04/2011VK
<1%
Sample Morphology
004A 13140-2A
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 50 Homogeneous Green/Cream Textured Coating
Chrysotile Non-Detected Binder/Filler< 1% Paint
(2) 50 Homogeneous White/Brown Drywall None Detected Cellulose fiber Binder/Filler1% Tape
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
<1%
Sample Morphology
005A 13140-2B
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: No other material found in the sample.
100 Homogeneous White Textured Coating Chrysotile Non-Detected Binder/Filler< 1% Paint
02/04/2011VK
<1%
Sample Morphology
006A 13140-2C
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 50 Homogeneous White Textured Coating Chrysotile Non-Detected Binder/Filler< 1% Paint
(2) 50 Homogeneous White/Brown Drywall None Detected Cellulose fiber Binder/Filler1% Tape
02/04/2011VK
<1%
Sample Morphology
007A 13140-2D
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: No other material found in the sample.
100 Homogeneous Beige/White Textured Coating
Chrysotile Non-Detected Binder/Filler< 1% Paint
02/04/2011VK
Sample Morphology
008A 13140-2E
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: No other material found in the sample.
100 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler Paint
02/04/2011VK
Sample Morphology
009A 13140-2F
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: No other material found in the sample.
100 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler Paint
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
010A 13140-2G
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: No other material found in the sample.
100 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler Paint
02/04/2011VK
Sample Morphology
011A 13140-3A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Yellow Carpet Mastic None Detected Synthetic fiber Binder/Filler1%
02/04/2011VK
Sample Morphology
012A 13140-3B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Yellow Carpet Mastic None Detected Synthetic fiber Binder/Filler1%
(2) 30 Homogeneous Green Carpet Mastic None Detected Synthetic fiber Binder/Filler1%
(3) 10 Homogeneous Brown Carpet Mastic None Detected Non-Detected Binder/Filler
(4) 30 Homogeneous Multi-Colored Fibers None Detected Synthetic fiber Binder/Filler95%
02/04/2011VK
Sample Morphology
013A 13140-3C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 90 Homogeneous Yellow Carpet Mastic None Detected Non-Detected Binder/Filler
(2) 5 Homogeneous Off-White Mineral Mixture None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
014A 13140-4A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 67 Homogeneous Beige Cove Base None Detected Non-Detected Binder/Filler Rubber
(2) 3 Homogeneous Gray Mastic None Detected Non-Detected Binder/Filler
(3) 20 Homogeneous Brown Mastic None Detected Cellulose fiber Binder/Filler1%
Paint
(4) 10 Homogeneous White Mineral Mixture None Detected Non-Detected Binder/Filler 67%
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
015A 13140-4B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 75 Homogeneous Beige Cove Base None Detected Non-Detected Binder/Filler Rubber
(2) 20 Homogeneous Brown Mastic None Detected Cellulose fiber Binder/Filler1%
(3) 5 Homogeneous White Mineral Mixture None Detected Non-Detected Binder/Filler
Paint Tape
02/04/2011VK
Sample Morphology
016A 13140-4C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 50 Homogeneous Beige Cove Base None Detected Non-Detected Binder/Filler Rubber
(2) 20 Homogeneous Brown Mastic None Detected Cellulose fiber Binder/Filler1% Paint
(3) 30 Homogeneous White Mineral Mixture None Detected Non-Detected Binder/Filler Tape
02/04/2011VK
Sample Morphology
017A 13140-5A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 75 Homogeneous Brown Cove Base None Detected Non-Detected Binder/Filler Rubber
(2) 20 Homogeneous Brown Mastic None Detected Non-Detected Binder/Filler Paint
(3) 5 Homogeneous White Mineral Mixture None Detected Non-Detected Binder/Filler Tape Paint
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
018A 13140-5B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 80 Homogeneous Brown Cove Base None Detected Non-Detected Binder/Filler Rubber
(2) 20 Homogeneous Brown Mastic None Detected Non-Detected Binder/Filler Paint Tape
02/04/2011VK
<1%
Sample Morphology
019A 13140-5C
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 70 Homogeneous Brown Cove Base None Detected Non-Detected Binder/Filler Rubber
(2) 5 Homogeneous White Mastic None Detected Non-Detected Binder/Filler
(3) 20 Homogeneous Brown Mastic None Detected Cellulose fiber Binder/Filler1%
Paint
(4) 5 Homogeneous White Mineral Mixture Chrysotile Non-Detected Binder/Filler 67%< 1%
Tape Paint
02/04/2011VK
Sample Morphology
020A 13140-6A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: Foil not tested.
97 Homogeneous White/Silver Paper Pipe Wrap
None Detected Cellulose fiber Binder/Filler80% Fibrous glass Foil10%
(2) 1 Homogeneous Tan Mastic None Detected Non-Detected Binder/Filler
(3) 2 Homogeneous Clear Mastic None Detected Cellulose fiber Binder/Filler1%
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
021A 13140-6B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: Foil not tested.
99 Homogeneous White/Silver Paper Pipe Wrap
None Detected Cellulose fiber Binder/Filler80% Fibrous glass Foil10% Mineral wool 3%
Synthetic fiber 1%
(2) 1 Homogeneous Cream Mastic None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
022A 13140-6C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1)
Layer Comment: Foil not tested.
99 Homogeneous White/Silver Paper Pipe Wrap
None Detected Cellulose fiber Binder/Filler80% Fibrous glass Foil2% Mineral wool 10%
(2) 1 Homogeneous Cream Mastic None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
023A 13140-7A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
024A 13140-7B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
025A 13140-7C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Grout None Detected Non-Detected Binder/Filler Rust
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
026A 13140-8A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) Layer Comment: Color different than noted on COC.
100 Homogeneous Gray Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
027A 13140-8B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) Layer Comment: Color different than noted on COC.
50 Homogeneous Gray Grout None Detected Non-Detected Binder/Filler
(2) 50 Homogeneous White Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
028A 13140-8C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) Layer Comment: Color different than noted on COC.
90 Homogeneous Gray Grout None Detected Non-Detected Binder/Filler
(2) 10 Homogeneous White Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
029A 13140-9A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
02/04/2011VK
Sample Morphology
030A 13140-9B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
02/04/2011VK
Sample Morphology
031A 13140-9C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
032A 13140-9D
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
02/04/2011VK
Sample Morphology
033A 13140-9E
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
02/04/2011VK
Sample Morphology
034A 13140-9F
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
02/04/2011VK
Sample Morphology
035A 13140-9G
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous White Spray-on Acoustic Celling
None Detected Non-Detected Binder/Filler Styrofoam
02/04/2011VK
Sample Morphology
036A 13140-10A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 95 Homogeneous Gray Floor Tile None Detected Non-Detected Binder/Filler
(2) 5 Homogeneous Tan Mastic None Detected Cellulose fiber Binder/Filler1%
02/04/2011VK
Sample Morphology
037A 13140-10B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 97 Homogeneous Gray Floor Tile None Detected Non-Detected Binder/Filler
(2) 3 Homogeneous Tan Mastic None Detected Cellulose fiber Binder/Filler1%
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
038A 13140-10C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 97 Homogeneous Gray Floor Tile None Detected Non-Detected Binder/Filler
(2) 3 Homogeneous Tan Mastic None Detected Cellulose fiber Binder/Filler1%
02/04/2011VK
3%
Sample Morphology
039A 13140-11A
Total
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 1 Homogeneous Black Mastic Chrysotile Non-Detected Binder/Filler3%
(2) 94 Homogeneous Gray Floor Tile Chrysotile Non-Detected Binder/Filler3%
(3) 3 Homogeneous White Mineral Mixture None Detected Non-Detected Binder/Filler
(4) 2 Homogeneous Cream Mastic None Detected Cellulose fiber Binder/Filler1%
02/04/2011VK
Sample Morphology
040A 13140-11B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 70 Homogeneous White Mineral Mixture None Detected Non-Detected Binder/Filler
(2) 30 Homogeneous Cream Mastic None Detected Cellulose fiber Binder/Filler1%
02/04/2011VK
Sample Morphology
041A 13140-11C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 40 Homogeneous Tan Mastic None Detected Cellulose fiber Binder/Filler2%
(2) 60 Homogeneous Cream Mastic None Detected Synthetic fiber Binder/Filler3%
02/04/2011VK
Sample Morphology
042A 13140-12A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Beige Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
043A 13140-12B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Beige Grout None Detected Non-Detected Binder/Filler
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
044A 13140-12C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Beige Grout None Detected Non-Detected Binder/Filler
02/04/2011VK
Sample Morphology
045A 13140-13A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Black/White Roofing Mastic
None Detected Non-Detected Binder/Filler Rock
02/04/2011VK
Sample Morphology
046A 13140-13B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Black/White Roofing Mastic
None Detected Non-Detected Binder/Filler Rock
02/04/2011VK
Sample Morphology
047A 13140-13C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 100 Homogeneous Black/White Roofing Mastic
None Detected Non-Detected Binder/Filler Rock
02/04/2011VK
Sample Morphology
048A 13140-14A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 2 Homogeneous Silver Paint None Detected Non-Detected Binder/Filler
(2) 98 Homogeneous Gray Duct Sealant None Detected Non-Detected Binder/Filler
Rubber
02/04/2011VK
Sample Morphology
049A 13140-14B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 2 Homogeneous Silver Paint None Detected Non-Detected Binder/Filler
(2) 98 Homogeneous Gray Duct Sealant None Detected Non-Detected Binder/Filler
Rubber
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
050A 13140-14C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 2 Homogeneous Silver Paint None Detected Non-Detected Binder/Filler
(2) 98 Homogeneous Gray Duct Sealant None Detected Non-Detected Binder/Filler
Rubber
02/04/2011VK
Sample Morphology
051A 13140-15A
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
02/04/2011VK
Sample Morphology
052A 13140-15B
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
02/04/2011VK
Sample Morphology
053A 13140-15C
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
02/04/2011VK
Sample Morphology
054A 13140-15D
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Method Reference: EPA-600/M4-82-020/EPA/600/R-93/116/NYELAP 198.1
Sample Type: Bulk
Date Received: 1/31/2011
ANALYTICAL RESULTS
Report Date: 14-Feb-11
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/04/2011VK
Sample Morphology
055A 13140-15E
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
02/04/2011VK
Sample Morphology
056A 13140-15F
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
02/04/2011VK
Sample Morphology
057A 13140-15G
Layer POB Asbestos % Other Fibers % Particulate
01/25/2011
(1) 30 Homogeneous Beige Textured Coating None Detected Non-Detected Binder/Filler
(2) 70 Homogeneous White Textured Coating None Detected Non-Detected Binder/Filler
Perlite
Laboratory Limits
Range R Limit
Laboratory
Quartile Limit 0.1-1 100 +/- 1.482
10-100 100 +/- 22.23 1-10 100 +/- 7.41 Trace 100 +/- 1.482
Range R Limit
Vera Khorosh ( VK)
Quartile Limit 0.1-1 100 +/- 1.482
10-100 100 +/- 26.676 1-10 100 +/- 5.928 Trace 100 +/- 1.482
Analyst(s) Name/Date: 2/14/2011
The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
Client Reference: 25009-009558.00/300-VANDENBERG AFB (BLDG 131
Method Referenc Asbestos Point Counting by PLM- California Method
Sample Type: Bulk
Date Received: 1/31/2011
2/14/2011 1:46:0Report Date:
ANALYTICAL RESULTS
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK001A 13140-1A 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 100 Homogeneous Friable White Paint/Joint
Compound
3 0.30
Chrysotile 3 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.30 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK002A 13140-1B 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 70 Homogeneous Friable White Paint/Joint
Compound
2 0.20
Chrysotile 2 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.20 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
(2) 30 Homogeneous Friable White Joint
Compound/Tape
2 0.20
Chrysotile 2 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.20 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
Method Referenc Asbestos Point Counting by PLM- California Method
Sample Type: Bulk
Date Received: 1/31/2011
2/14/2011 1:46:0Report Date:
ANALYTICAL RESULTS
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK003A 13140-1C 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 30 Homogeneous Friable White Joint
Compound
3 0.30
Chrysotile 3 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.30 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
(2) 70 Homogeneous Friable White Joint
Compound/Tape
5 0.50
Chrysotile 5 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.50 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK004A 13140-2A 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 100 Homogeneous Friable Green/Cream
Textured Coating
5 0.50
Chrysotile 5 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.50 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
Method Referenc Asbestos Point Counting by PLM- California Method
Sample Type: Bulk
Date Received: 1/31/2011
2/14/2011 1:46:0Report Date:
ANALYTICAL RESULTS
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK005A 13140-2B 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 100 Homogeneous Friable White Textured
Coating
3 0.30
Chrysotile 3 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.30 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK006A 13140-2C 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 100 Homogeneous Friable White Textured
Coating
5 0.50
Chrysotile 5 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.50 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK007A 13140-2D 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 100 Homogeneous Friable Beige/White
Textured Coating
2 0.20
Chrysotile 2 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.20 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
Method Referenc Asbestos Point Counting by PLM- California Method
Sample Type: Bulk
Date Received: 1/31/2011
2/14/2011 1:46:0Report Date:
ANALYTICAL RESULTS
CLIENT: BUREAU VERITAS - PLEASANTON
Date: 14-Feb-11
Lab ID Client Sample ID Analyst Date AnalyzedDate Sampled
02/14/2011VK019A 13140-5C 01/25/2011
Sample MorphologyLayer POB No. Points Counted Identification %Count
(1) 100 Homogeneous Friable White Mineral
Mixture
3 0.30
Chrysotile 3 Amosite 0
Crocidolite 0 Anthophyllite 0
Actinolite 0 Tremolite 0
0.30 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1
TOTALS
Analyst(s) Name/Date: 2/14/2011
Date Received: 1/31/2011 Report Date: 2/14/2011 1:46:07 PMSample Type: Bulk
Analytical Method: TEM Full-Quant Analysis EPA/600/R-93/116
Grid Box Identification: 02-10-11D-1
Lab Sample No.
Client Sample Identification
Date Sampled
Analysis Date Analyst
Reporting Limit (% by Weight): 0.1
Sample Description (Morphology)
Asbestos Total Asbestos (%)**(%)*Identification
ANALYTICAL RESULTS
Client: BUREAU VERITAS - PLEASANTON
25009-009558.00/300-VANDENBERG AFB (BLDG 13140)Client Reference No.:
Work Order No.: A1102024 Date: 14-Feb-11
A1102024-036A 13140-10A 01/25/11 @12:00 am
02/14/11 @12:02 pm
KRP Beige Tile None Detected -- < 0.1
A1102024-045A 13140-13A 01/25/11 @12:00 am
02/14/11 @12:02 pm
KRP Black Tar None Detected -- < 0.1
Instrument *Magnification Calibration Date
TEM Microscope Documentation Accelerating
Voltage
TEM 1/D675 14400x 2/9/2011100 KeV
*Magnification = Calibrated screen magnification at 15,000X. For ISO Method 10312 the calibrated screen magnification is at 20,000X
Analyst(s) Name/Date:
Result is less than the indicated limit of detection.<:
2/14/2011
--: Present but below the detection limit The visual area estimation of asbestos content in the final residue.*:
**: The calculated total percent asbestos in the sample as received.
02/08/2011 01:10 PM
To Tiffany Dixon/USA/VERITAS@VERITAS cc bcc
Subject Fw: Project No: 2500900955800 / Lab Workorder:
A1102024 (BLDG 13140)
Ref
----- Forwarded by Vera Khorosh/USA/VERITAS on 02/08/2011 01:10 PM -----
02/08/2011 01:05 PM
To Vera Khorosh/USA/VERITAS@VERITAS cc Jeremy Gress/USA/VERITAS@VERITAS, Jeremy MacMann/USA/VERITAS@VERITAS
Subject Re: Project No: 2500900955800 / Lab Workorder: A1102024
(BLDG 13140)
Hi Vera, Please conduct the following additional analysis:
1. Lab ID 1A-3A: PLM point count (1000) layers 1 and 2 (joint compound)
2. Lab ID 4A-7A: PLM point count (1000) layers 1 (textured coating)
3. Lab ID 19A: PLM point count (1000) layers 4 (white mineral mixture)
4. Lab ID 36A: quantitative transmission electron microscopy with gravimetric reduction on layers 1 (VFT).
5. Lab ID 45A: quantitative transmission electron microscopy with gravimetric reduction (black/white roofing).
Thanks for the help!
-Michael
-----Vera Khorosh/USA/VERITAS wrote: -----
To: Michael-Ray.Boyden@us.bureauveritas.com From: Vera Khorosh/USA/VERITAS Date: 02/07/2011 11:48AM Subject: Project No: 2500900955800 / Lab Workorder: A1102024
Your results have been copied to the R:\Lab Folders directory under your office location and will be available after server replication within the hour. If you do not receive the file please contact the HelpDesk.
Regards, The Bureau Veritas Team
3380 Chastain Meadows Parkway mailto:Michael-Ray.Boyden@us.bureauveritas.com
Suite 300 Kennesaw, Georgia 30144-
(770) 499-7701
[attachment "FR_A1102024Ver01.pdf" removed by Michael Boyden/USA/VERITAS]
Michael Boyden/USA/VERITAS
02/09/2011 11:37 AM
To Kathy Cannon/USA/VERITAS@VERITAS cc Carol Findlay/USA/VERITAS@VERITAS, Jon Perrenoud/USA/VERITAS@VERITAS, Nadiya Gapon/USA/VERITAS@VERITAS, Tiffany bcc
Subject Re: Roofing - Vandenberg projects - analyze as TEM FQ composite
This is correct. Sorry for all the trouble.
Michael-Ray Boyden, CAC Project Manager Bureau Veritas North America, Inc.
Health, Safety, and Environmental Services ISO 9001:2008 Certified 2430 Camino Ramon, Suite # 122 San Ramon, CA 94583 p: 925.498.6520, c: 925.382.7788, f: 925.426.0106 michael.boyden@us.bureauveritas.com www.us.bureauveritas.com/hse
Kathy Cannon/USA/VERITAS
Kathy Cannon/USA/VERITAS
02/09/2011 08:36 AM
To Michael Boyden/USA/VERITAS@VERITAS cc Vera Khorosh/USA/VERITAS@VERITAS, Carol Findlay/USA/VERITAS@VERITAS, Jon Perrenoud/USA/VERITAS@VERITAS, Tiffany Dixon/USA/VERITAS@VERITAS, Nadiya Gapon/USA/VERITAS@VERITAS
Subject Roofing - Vandenberg projects - analyze as TEM FQ composite
HI, Michael-Ray!
We will re-log in all the roofing samples as TEM FQ composites, per your request. Can you please respond and verify that this is correct?
Thanks!
Kathy Cannon Microscopist Bureau Veritas North America, Inc.
Health, Safety and Environmental Services 3380 Chastain Meadows Parkway, Suite 300 Kennesaw, GA 30144 Office: 770.590.6682, VOIP *706682, Fax: 770.499.7511 kathy.cannon@us.bureauveritas.com http://www.us.bureauveritas.com/labs
This material is confidential and intended solely for the person to whom it is addressed. If this is received in error, please contact the number provided.
Bureau Veritas North America, Inc.
Health, Safety, and Environmental Services 3380 Chastain Meadows Parkway, Suite 300 Kennesaw, GA 30144
Main: (770) 499-7701 Fax: (770) 499-7511 www.us.bureauveritas.com
March 28, 2011
BUREAU VERITAS - PLEASANTON
Michael-Ray Boyden
Dear Michael-Ray Boyden:
Reference: VANDENBERG AFB BLDG 13140B/ 25009-009558.00.300
Bureau Veritas Work Order No. A1103232
2430 Camino Ramon
San Ramon, CA 94583- Suite 122
Bureau Veritas North America, Inc. received 6 samples on March 18, 2011 for the analyses presented in the following report.
The results apply only to the samples analyzed in this project. Please note that any unused portion of the samples will be discarded after a thirty-day holding period, unless you have requested otherwise.
We appreciate the opportunity to assist you. If you have any questions concerning the report, please contact the analyst whose name appears on the report or myself at (770) 499-7701.
Sincerely, Alan M. Segrave, P.G.
Director, Laboratory Services Electronic signature authorized through password protection
Tim Coecc:
http://www.us.bureauveritas.com
28-Mar-11Date:CASE NARRATIVE
Project: VANDENBERG AFB BLDG 13140B/ 25009-009558.00.300
CLIENT: BUREAU VERITAS - PLEASANTON
Work Order No A1103232
ANALYTICAL METHOD FOR ASBESTOS IN BULK SAMPLES USING POLARIZED
LIGHT MICROSCOPY (PLM)
The results of this report relate only to the samples listed in the body of this report.
Unless otherwise noted below, the following statements apply: 1) all samples were received in acceptable condition, 2) all quality control results associated with this sample set were within acceptable limits and/or do not adversely affect the reported results, and 3) the industrial hygiene results have not been blank corrected unless otherwise noted.
Use of EPA/600/R-93/116 satisfies applicable requirements of the USEPA's "Interim Method for the Determination of Asbestos in Bulk Insulation Sample", EPA-600/M4-82-020, December 1982, published as Appendix E to Subpart E of 40CFR763. Bulk samples analyzed by New York State methods follow stratified point counting methods (198.1) or Method 198.6 for PLM non-friable organically bound materials (NYSDOH Lab Code –11645). Percentages are visual estimations of asbestos >10:1 aspect ratio. The reliable limit of quantitation of the method is 1%, although asbestos may be qualitatively detected at concentrations less than 1%. Samples for which asbestos is detected at <1% are reported as trace, "<1%". "None Detected" indicates that no asbestos fibers were observed.
NESHAP requires point counting of a bulk sample when the result is <10% by a method other than point counting. EPA, however states that if 3 mounts of the sample are analyzed and the asbestos percentage is <10% by visual estimation, the client may elect to assume the amount to be greater than 1% or require verification by point counting. If the result by point counting is different than the result obtained by visual estimation, the point count result will be used. Sample friability or non-friability noted on the report is a requirement for the State of California and refers only to the condition of the sample under macroscopic examination. It does not imply friability or non-friability for the sample as collected or observed in the field as determined by the person collecting the sample. The Kennesaw, Georgia lab is accredited by NVLAP –Lab Code 101125-0.
(a)Polarized- light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing. When analysis of such materials by PLM yields results negative for the presence of asbestos, Bureau Veritas recommends utilizing quantitative transmission electron microscopy (TEM). For more information, contact the laboratory.
References
Work Order No A1103232
McCrone, Walter C. 1980. The Asbestos Particle Atlas. Ann Arbor, MI: Ann Arbor Science Publishers, Inc.
United States Environmental Protection Agency. Environmental Monitoring Systems Laboratory.
1982. Interim Method for the Determination of Asbestos in Bulk Insulation Samples. EPA-600/M4-82-
020. Washington: GPO, December.
United States Environmental Protection Agency. Method for the Determination of Asbestos in Bulk Building Materials. EPA-600/R-93/116, July 1993 (PLM)
Fed. Reg. Vol. 55, No.224, 11/20/90, p.48415 (NESHAP) EPA Memorandum 5/8/1991 –NESHAP Clarifications
NYSDOH Methods 198.1/198.6
QUANTITATIVE ANALYSIS OF BULK SAMPLES FOR ASBESTOS USING TRANSMISSION
ELECTRON MICROSCOPY (TEM)
Upon receipt in the laboratory, samples are ground until homogeneous. Each sample is weighed in a tared silica crucible. The sample is placed in a muffle furnace at a temperature of 480C for at least 3 hours or until the weight has stabilized. The sample is allowed to cool to room temperature and immediately weighed to calculate percent organic loss.
Approximately 1 ml of nondiluted HCL acid is slowly added to remove calcite and dolomite from the ashed sample. After evolution of CO2 gas has ceased, the sample is immediately diluted with ultra-pure water. The sample is then dispersed in 50 ml of ultra-pure water and filtered onto a pre-weighed 47 mm,
0.45 um pore size, MCE filter. The filter is dried on a slide warmer…