Text version
TV
REFLECTED CEILING
LEGEND & SYMBOLS
2' X 2' ACT CEILING GRID SYSTEM; REFER TO FINISH
AND COLOR SCHEDULE; A600 FOR TYPES
GYPSUM BOARD CEILING SYSTEM
2' x 4' LIGHT, REFER TO ELECTRICAL DRAWINGS
2' x 2' LIGHT, REFER TO ELECTRICAL DRAWINGS
RECESSED CAN LIGHT, REFER TO ELECTRICAL
DRAWINGS
LINEAR LIGHT FIXTURE, REFER TO ELECTRICAL
DRAWINGS
ROOM NAME & NUMBER TAG:
REFER TO SHEET A600 FOR FINISHES
WORKING POINT
COLUMN GRID TAG
CENTERLINE
REVISION MARK1
Room Name A0000
EGGCRATE PARABOLIC LIGHT LENS
LINEAR METAL, REFER TO KEYNOTES
SUPPLY DIFFUSER, REFER TO MECHANICAL DRAWINGS
RETURN DIFFUSER, REFER TO MECHANICAL DRAWINGS
6 8 9 10 11
A
B
D
E
F
J
K
L
H
N
G
7 7.1 7.9 9.3 9.7
L.8
M
A301
A301
A301
A301
A301
A301
A301
A301
A511
A511
A311
A302
A302
A302
A302
A312
A511
A313
A.F.F.
GWB SYSTEM
9' - 6"
A.F.F.
2' x 2' ACT SYSTEM
8' - 4"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
9' - 6"
VESTIBULE
CARTS
CENTRAL
LOBBY
PSC
SECURITY
SCREENING
SECURE
GATE
CORRIDOR
DEPARTURE
GATE 2
ENHANCED
VENDING
AREA
FAMILY
LOUNGE
CRIB ROOM
ELEC.
BAGGAGE
CLAIM
DEPARTURE/ARRIVAL
GATE 3
CUSTOMS
MECHANICAL
LOST &
FOUND
MEN
WOMEN
WOMEN
MEN
ARRIVAL
WAITING
CAR
RENTAL
COVERED
CANOPY
AREA
BAGGAGE
BREAKDOWN
PLAY
ROOM
RESTROOM
SPRINKLER
RISER
ROOM
VESTIBULE
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
COMM.
CORRIDOR
CARTS
MEN
WOMEN
BAGGAGE
ACCESS
CONTROLLER
A.F.F.
GWB SYSTEM
10' - 0"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
2' x 2' ACT SYSTEM
9' - 0"
A.F.F.
GWB SYSTEM
9' - 6"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
8' - 0" A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
9' - 6"
A.F.F.
GWB SYSTEM
9' - 6"
A.
F.
F.
2' x
' A C
T
SY
ST
EM
8'
4"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
METAL SOFFIT
9' - 6 1/2"
A.F.F.
METAL SOFFIT
9' - 6 1/2"
A.F.F.
METAL SOFFIT
9' - 6 1/2"
A.F.F.
GWB SYSTEM
9' - 6"
A312
A.F.F.
GWB SYSTEM
9' - 6"
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
8' - 0"
A572
SIM
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
1'- 2"
1'-2"
1'- 2"
1'-2" 1'-2"
1'- 2"
1'- 2"
1'- 2"
4"
4"
4 1/2"
4" 4"
4"
4"
4"
2'-6"
2'-6"
2'- 6"
A552
A.F.F.
GWB SYSTEM
9' - 6"
NAA
N9.59.1
N8.5N7.7N7.1
NN.1
NQ
NP
N8.4 N8.6 N9.2 N9.8
NJ.4
NE.8
N7.8N7.05
NL.1
NK.9
NE.4
NA.9
C.4
NC.8
NC.5
N7.4
A122
A.F.F.
2' x 2' ACT SYSTEM
9' - 0"
A.F.F.
2' x 2' ACT SYSTEM
9' - 8"
A.F.F.
2' x 2' ACT SYSTEM
9' - 8"
A.F.F.
2' x 2' ACT SYSTEM
9' - 8"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
GWB SYSTEM
10' - 0 1/2"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A572
A572
A572
A.F.F.
2' x 2' ACT SYSTEM
8' - 4"
A.F.F.
GWB SYSTEM
8' - 0"A.F.F.
GWB SYSTEM
8' - 0"A.F.F.
2' x 2' ACT SYSTEM
8' - 4"
2'- 6"
A572
A572
A573
SIM
A572
A572
EXISTING CONCRETE SURFACE
TO BE PAINTED, PT1
8'-0" CASED
OPENING
8'-0" CASED
OPENING
8'-0" CASED
OPENING
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DIVIDED INTO TWO SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION)
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A121
RE
FL
EC
TE
D C
EI
LI
NG
P
LA
N
S
OU
TH
S
ID
E
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
NKEYLAN NOT TO SCALE
SOUTH
SIDE
0' 4' 8' 16'
SCALE: 1/8" = 1'-0"A040 A121
FIRST FLOOR REFLECTED
CEILING PLAN - SOUTH SIDE
NEW CONSTRUCTION
KEYNOTES
1 METAL LADDER AND ATTIC ACCESS HATCH, ANCHOR LADDER
SECURELY TO MASONRY WALL. REFER TO SPECIFICATION SECTION
05 51 33 - METAL LADDERS; COORDINATE WITH STRUCTURAL
DRAWINGS AND FRAMING PLANS.
13 SUSPENDED 3-DIMENSIONAL CURVED SYSTEM IS PART OF
FF&E-ANCILLARY ITEM #1; REFER TO ANCILLARY ITEM #1 NOTES ON
A410 & A411 - REFER TO SPECIFICATION SECTION 09 54 00. BASIS OF
DESIGN IS TWO-DIRECTIONAL USG CURVATURA SYSTEM WITH 2'x 2'
PANELS WITH 9/16" SUSPENSION SYSTEM WITH 5/32" REVEAL.
17 REPAIR ANY HOLES IN EXISTING CEILING. CLEAN SURFACE OF ALL
FOREIGN MATERIAL. DULL EXISTING SURFACE BY LIGHTLY ABRADING.
APPLY PAINT TO A TEST AREA, ALLOW TO DRY ONE WEEK BEFORE
TESTING ADHESION. IF ADHESION IS POOR, OR IF NEW PAINT
ATTACKS THE PREVIOUS FINISH, REMOVAL OF PREVIOUS FINISH MAY
BE NECESSARY IF EXISTING PAINT IS PEELING BADLY, CLEAN
SURFACE TO SOUND SUBSTRATE, PRIME AND PAINT. REFER TO 09 90
00 PAINT.
22 2" INSULATED METAL PANEL.
23 LINEAR METAL CEILING EXTERIOR.
24 LINEAR METAL CEILING INTERIOR.
TV
6 8
E
A301
A301
A301
A301
A301
A301
A301
A301
NJ.4
NE.8
N7.8N7.05
A.F.F.
GWB SYSTEM
9' - 6" A.F.F.
GWB SYSTEM
9' - 6"
A.F.F.
GWB SYSTEM
9' - 6" A.F.F.
GWB SYSTEM
9' - 6"
A.F.F.
GWB SYSTEM
8' - 0" A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
8' - 0"
A.
F.
F.
G
W B
SY
ST
EM
8'
0"
A.F.F.
GWB SYSTEM
8' - 0" A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
8' - 0"
A.F.F.
GWB SYSTEM
9' - 6"
A.F.F.
GWB SYSTEM
9' - 6"
6'-9 1/2" 3'-4" 4'-11" 2'-0" 30'-10 1/2" 2'-0" 4'-11" 3'-4" 6'-9 1/2" 1'-4"
2'-6"
1'-4" 1'-4"
3'- 4"
9'-
1/ 4"
2'- 0"
'-1
1/
2" 2'-
0" 9'-
1/
4" 3'-
4" 6'-
1/
4" 4'-
3/
4"
1'- 4"
1'- 4"
1'-4" 1'-4"
1'- 4"
1'- 4"
4'-7 3/4" 1'-4"
2'-6"
4'-7 3/4"
2'-6
1'-4
4'-7 3/4
A.
F.
F.
G
W B
SY
ST
EM
9'
6"
A.
F.
F.
G
W B
SY
ST
EM
9'
6"
135.00° 135.00°
135.00° 135.00°
135.00°
5.
° 135.00°
'-7
7'-11" 32'-2 1/2" 7'-11"
48'-0 1/2"
1'-4" 8"1'-8" 1'-8" 8" 1'-4" 1'-8" 1'-8"
8" 8"
8" 8"
3'- 6"
'-5
/4
'-2
/2
'-5
/4
4'-6 1/4" 23'-2 1/4" 4'-6 1/4"
1'- 8"
1'- 8"
1'- 8"
1'- 8"
1'-4
4'-7 3/4
8" 8"
8"
8" 8"8" 8"
8" 8"
8" 8"
8" 8" 13 5.
A.
F.
F.
2' x
' A C
T
SY
ST
EM
" A.
F.
F.
2' x
' A
C T
SY
ST
EM
" A.
F.
F.
2' x
' A C
T
SY
ST
EM
" A.
F.
F.
2' x
' A
C T
SY
ST
EM
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
2'- 0"
A572
A572
A572
A572
A573
A573
A573
A573
A573
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
A572
8" 1'-
4" 8"
1'- 4"
A572
A572
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A572
A572
A572
4'-0 " 4'-0"
7'-4 1/2"7'-4 1/2
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A.F.F.
2' x 2' ACT SYSTEM
10' - 0"
A572
A572
A572
REFLECTED CEILING
LEGEND & SYMBOLS
2' X 2' ACT CEILING GRID SYSTEM; REFER TO FINISH
AND COLOR SCHEDULE; A600 FOR TYPES
GYPSUM BOARD CEILING SYSTEM
2' x 4' LIGHT, REFER TO ELECTRICAL DRAWINGS
2' x 2' LIGHT, REFER TO ELECTRICAL DRAWINGS
RECESSED CAN LIGHT, REFER TO ELECTRICAL
DRAWINGS
LINEAR LIGHT FIXTURE, REFER TO ELECTRICAL
DRAWINGS
ROOM NAME & NUMBER TAG:
REFER TO SHEET A600 FOR FINISHES
WORKING POINT
COLUMN GRID TAG
CENTERLINE
REVISION MARK1
Room Name A0000
EGGCRATE PARABOLIC LIGHT LENS
LINEAR METAL, REFER TO KEYNOTES
SUPPLY DIFFUSER, REFER TO MECHANICAL DRAWINGS
RETURN DIFFUSER, REFER TO MECHANICAL DRAWINGS
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A122
EN
LA
RG
ED
R
EF
LE
C
TE
D C
EI
LI
NG
P
LA
N
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 1/4" = 1'-0"A120 A122
1 ELARGED CEILING PLAN - CENTRAL LOBBY
NEW CONSTRUCTION
KEYNOTES
13 SUSPENDED 3-DIMENSIONAL CURVED SYSTEM IS PART OF
FF&E-ANCILLARY ITEM #1; REFER TO ANCILLARY ITEM #1 NOTES ON
A410 & A411 - REFER TO SPECIFICATION SECTION 09 54 00. BASIS OF
DESIGN IS TWO-DIRECTIONAL USG CURVATURA SYSTEM WITH 2'x 2'
PANELS WITH 9/16" SUSPENSION SYSTEM WITH 5/32" REVEAL.
0' 2' 4' 8'
VTR
ROOF PLAN LEGEND
DOWN SPOUT (DS) CONNECTED TO STORM SYSTEM;
REFER CIVIL DRAWINGS.
STANDING SEAM METAL ROOF PANEL; REFER TO
EXTERIOR MATERIAL SCHEDULE A201
PLUMBING VENT THRU ROOF; REFER TO
1/A513 FOR DETAIL
DS
RAIN CHAIN CONNECTED TO STORM SYSTEM;
REFER TO CIVIL DRAWINGS.
RC
EDGE OF WALL BELOW
EXHAUST FAN THRU ROOF; REFER TO A513
FOR CURB DETAIL & MECHANICAL
ROOF TOP VENTILATOR THRU ROOF; REFER
TO A513 FOR CURB DETAIL & MECHANICAL
1 2
3 4 5 6 8
A
B
C
D
E
H
N
75.2 7.1 7.9
L.8
M
A301
A301
A301
A301
A301
A301
A301
A301
A310
NEW ROOF
EDGE OF
WALL BELOW
A511
A311
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK1
A310
A302
A302
A302
A302
SLOPE: 1 1/2" / 12"
SL
O
PE
: 1
/2
/ 1
2"
DS
DS
DS
DS
DS DS
DS
RC
RC
SL
O
PE
: 1
/2
/ 1
2"
SL
O
PE
: 1
/2
/ 1
2"
SLOPE: 1 1/2" / 12"
SLOPE: 1 1/2" / 12"
RC
RC
GUTTER GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
TROUGH
GUTTER
A512
A512
NAA
N7.7N7.1
NM.2
NN.1
NQ
N3.1 N4.1 N5.1 N5.6
NJ.4
NE.8
N7.8N7.05
NL.1
NK.9
NE.4
NA.9
NC.8
N7.4
EDGE OF WALL BELOW
VTR
VTR
VTR
VTR
SLOPE: 1 1/2" / 12"
SL
O
PE
: 1
/2
/ 1
2"
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DIVIDED INTO TWO SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION)
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A130
RO
OF
P
LA
N
N
OR
TH
S
ID
E
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
NN
KEYLAN NOT TO SCALE
NORTH
SIDE
SCALE: 1/8" = 1'-0"A130
1 ROOF PLAN - NORTH SIDE
0' 4' 8' 16'
ROOF PLAN NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES.
2 REFER TO A513 FOR ROOF DETAILS
3 VENT THROUGH ROOFS AND OTHER ROOF PENESTRATIONS ARE
INDICATED FOR DETAIL COORDINATION. THE CONTRACTOR IS
RESPONSIBLE FOR LOCATING ANY AND ALL ROOF PENETRATIONS.
PENETRATIONS INCLUDE BUT AREN'T LIMITED TO VENTS THROUGH
ROOF, BOILER FLUES, EXHAUSTS AND OTHER MECHANICAL
EQUIPMENT. REFER TO MECHANICAL DRAWINGS.
4 IN THE ABSENCE OF DETAIL FOR ANY CONDITION ON THE ROOF, THE
MOST STRINGENT CONDITION OF THE CURRENT NRCA/SMACNA
SHALL APPLY.
NEW CONSTRUCTION
KEYNOTES
26 EXHAUST FAN - REFER TO MECHANICAL.
27 ROOF TOP VENTILATOR - REFER TO MECHANICAL
28 VENT PIPE - REFER TO MECHANICAL
33 EXPOSED STRUCTURAL STEEL TRUSSES, BEAMS, PURLINS, BRACING
AND COLUMNS TO BE FINISHED WITH COATING 2 (C2); REFER TO
EXTERIOR MATERIAL COLOR SCHEDULE, A201 FOR ADDITIONAL
INFORMATION.
GENERAL ROOF NOTES
1 IN THE ABSENCE OF DETAIL FOR ANY CONDITION ON THE ROOF, THE
MOST STRINGENT CONDITION OF THE CURRENT NRCA/SMACNA SHALL
APPLY.
2 ALL CLARIFICATIONS OR ADDITIONAL INFORMATION NEEDED SHALL BE
IN ACCORDANCE WITH THE CRITERIA AND DETAILS OF THE NRCA
ROOFING AND WATERPROOFING MANUAL AND SMACNA
ARCHITECTURAL SHEET METAL MANUAL. ANY DEVIATIONS FOR THE
SPECIFIED OR INDICATED REQUIREMENTS SHALL BE SUBMITTED FOR
APPROVAL BY THE ARCHITECT PRIOR TO INSTALLATION.
3 FOLLOW RECOMMENDAITONS AND GUIDELINES OF THE SMACNA
MANUAL, 6TH ED., FOR DETAIL CLARIFICATIONS IN REFERENCE TO
SHEET METAL WORK.
4 FOLLOW RECOMMENDAITONS AND GUIDELINES OF THE NRCA MANUAL,
5TH ED., FOR DETAIL CLARIFICATIONS IN REFERENCE TO MEMBRANE
ROOF.
5 NO ROOFING KETTLE SHALL COME WITHIN 250 FEET OF OCCUPIED
AREAS.
6 NO CURB SHALL COME WITHIN 8 INCHES OF VALLEY OR CRICKET LINE.
ADJUST THE TAPERED INSULTION ACCORDING T THE ACTUAL CURB
PLACEMENTS.
7 PROVIDE CRICKETS AT ALL ROOFTOP EQUIPMENT LOCATIONS
RUNNING PERPENDICULAR TO THE ROOF SLOPE THAT EXCEED 24
INCHES WIDE.
8 PREFABRICATE FLASHING CORNERS AND ENDS WITH MINIMUM 18 INCH
RETURNS.
9 PROVIDE CONCEALED JOINT COVER PLATE IN FLASHING WITH 12 INCH
WIDE SPLICE SHEET CENTERED ON SEAM. APPLY TWO ROWS OF
BUTYL TAPE EACH SIDE OF JOINT AND PROVIDE SEALANT AT SEAM.
10 ALL SHEET METAL TERMINATIONS TO HAVE HEMMED EDGES. NO
EXPOSED CUT EDGES.
11 ADD ADDITIONAL LAYER OF ROOFING MEMBRANE BELOW LOW SLOPE
ROOF WHERE WATER SHEET DRAINS FROM HIGH TO LOW.
12 PROVIDE STAINLESS STEEL FLASHING MATERIAL AT LOCATIONS
WHERE WATER SHEET DRAINS FROM HIGH TO LOW.
VTR
ROOF PLAN LEGEND
DOWN SPOUT (DS) CONNECTED TO STORM SYSTEM;
REFER CIVIL DRAWINGS.
STANDING SEAM METAL ROOF PANEL; REFER TO
EXTERIOR MATERIAL SCHEDULE A201
PLUMBING VENT THRU ROOF; REFER TO
1/A513 FOR DETAIL
DS
RAIN CHAIN CONNECTED TO STORM SYSTEM;
REFER TO CIVIL DRAWINGS.
RC
EDGE OF WALL BELOW
EXHAUST FAN THRU ROOF; REFER TO A513
FOR CURB DETAIL & MECHANICAL
ROOF TOP VENTILATOR THRU ROOF; REFER
TO A513 FOR CURB DETAIL & MECHANICAL
6 8 9 10 11
A
D
E
F
J
K
L
H
N
G
7 7.1 7.9 9.3 9.7
L.8
M
A301
A301
A301
A301
A301
A301
A301
A301
EDGE OF WALL BELOW
A511
A511
A511
A311
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
DKFX 11-1122 A
"MC" WORK
A302
A302
A302
A302
A511
A313
SL
O
PE
: 1
/2
/ 1
2"
SLOPE: 1 1/2" / 12"
DS
DS
DS
DS
DS
DS
DSDS
DS
RC
RC
RC
RC
GUTTERGUTTERGUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER
GUTTER GUTTER
GUTTER
GUTTER
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
A513
SIM
RC
TROUGH
GUTTER
NAA NAA
N9.59.1
N8.5N7.7N7.1
NN.1
NQ
NP
N8.4 N8.6 N9.2 N9.8
NJ.4
NE.8
N7.8N7.05
NL.1
NE.4
NA.9 NA.9
C.4
NC.8 NC.8
NC.5
N7.4
EDGE OF WALL BELOW
VTR
VTR
VTR
VTR
SL
O
PE
: 1
/2
/ 1
2"
SLOPE: 1 1/2" / 12"
SL
O
PE
: 1
/2
/ 1
2"
SL
O
PE
: 1
/2
/ 1
2"
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DIVIDED INTO TWO SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION)
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A131
RO
OF
P
LA
N
S
OU
TH
S
ID
E
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
NN
KEYLAN NOT TO SCALE
SOUTH
SIDE
SCALE: 1/8" = 1'-0"A131
1 ROOF PLAN - SOUTH SIDE
0' 4' 8' 16'
ROOF PLAN NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES.
2 REFER TO A513 FOR ROOF DETAILS
3 VENT THROUGH ROOFS AND OTHER ROOF PENESTRATIONS ARE
INDICATED FOR DETAIL COORDINATION. THE CONTRACTOR IS
RESPONSIBLE FOR LOCATING ANY AND ALL ROOF PENETRATIONS.
PENETRATIONS INCLUDE BUT AREN'T LIMITED TO VENTS THROUGH
ROOF, BOILER FLUES, EXHAUSTS AND OTHER MECHANICAL
EQUIPMENT. REFER TO MECHANICAL DRAWINGS.
4 IN THE ABSENCE OF DETAIL FOR ANY CONDITION ON THE ROOF, THE
MOST STRINGENT CONDITION OF THE CURRENT NRCA/SMACNA
SHALL APPLY.
NEW CONSTRUCTION
KEYNOTES
26 EXHAUST FAN - REFER TO MECHANICAL.
27 ROOF TOP VENTILATOR - REFER TO MECHANICAL
28 VENT PIPE - REFER TO MECHANICAL
33 EXPOSED STRUCTURAL STEEL TRUSSES, BEAMS, PURLINS, BRACING
AND COLUMNS TO BE FINISHED WITH COATING 2 (C2); REFER TO
EXTERIOR MATERIAL COLOR SCHEDULE, A201 FOR ADDITIONAL
INFORMATION.
FIRST FLOOR
EL.0' - 0"
3 4 5 6 11
A301
A301
A301
A301
AA
A A
172A101A DD
A
A
INSULATED METAL
PANELS
BRICK INFILL, TYP;
STAGGER JOINTS
INSULATED
METAL PANELS INSULATED
METAL PANELS
A302
A302
A302
A302
A313
A502
A
GUTTER
METAL FASCIA
INSULATED
METAL PANELS
STANDING SEAM
METAL ROOF PANELS
AUTOMATIC SLIDING
ENTRANCE DOOR
(IMPACT); REFER TO
DOOR SCHEDULE
ALUM.
STOREFRONT, TYP.
DOWNSPOUT
STANDING SEAM
METAL ROOF PANELS
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
BREAK METAL
TRIM
BRICK INFILL,
TYP; STAGGER
JOINTS
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
GUTTER
STANDING SEAM
METAL ROOF PANELS
METAL FASCIA
METAL TRUSS, COATING 2 (C2);
REFER TO STRUCTURAL DWGS.
GUTTER
STANDING SEAM
METAL ROOF PANELS
AUTOMATIC SLIDING
ENTRANCE DOOR (IMPACT)
CAST STONE, TYP.
GUTTER
DS DS RC RC
BREAK METAL
TRIM
BRICKMETAL FENCE DSBUILDING NUMBER
SIGN, TYPE B5.
REFER TO 4/A514
Z
N9.59.1N8.5N7.7N7.1 N10.9N10.6N9.9N7.8N7.05
2727 26 26
LIMITS OF BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT IRON ENCLOSURE
INCLUDING GATE AND FOOTINGS; PLAY AREA AND PLAY STRUCTURE SURFACE
MATERIALS, SITE LIGHTING, DRINKING FOUNTAIN AND ALL ASSOCIATED WORK EXCEPT
FOR THE FF&E PLAY STRUCTURE INCLUDING THE SHADE STRUCTURE AND PLAY AREA
FURNITURE. REFER TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE, PLUMBING AND
ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT AWARDED THE PLAY STRUCTURE,
PLAY AREA SURFACING AND PLAY AREA FURNITURE WILL NOT BE AWARDED EITHER.
BRICK, TYP.
BREAK METAL
TRIM
33 3333
NEW BRICK
ROWLOCK
NEW BRICK
ROWLOCK
NEW BRICK
ROWLOCK
BUILDING NUMBER
SIGN, TYPE B5.
REFER TO 4/A514
16433
29 29
FIRST FLOOR
EL.0' - 0"
1 2 3
A310
A
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
BRICK
INSULATED METAL
PANELS, TYP.
ALUM.
STOREFRONT, TYP.
BREAK METAL
TRIM
DS
N3.1
NEW BRICK
ROWLOCK
FIRST FLOOR
EL.0' - 0"
346891011 79.39.7
A301
A301
A301
A301
A502
BREAK METAL
TRIM, TYP.
GUTTER
ALUM. STOREFRONT
ENTRANCES, TYP.
BRICK
PIER, TYP.
METAL TRUSS, COATING 2 (C2);
REFER TO STRUCTURAL DWGS.
METAL FASCIA
INSULATED
METAL PANELS
METAL FASCIA
INSULATED METAL PANELS 1
A311
A311
144B156A
CAST STONE
CAP, TYP.
A302
A302
A302
A302
STANDING SEAM
METAL ROOF PANELS
ALUM.
STOREFRONT
BRICK INFILL,
TYP; STAGGER
JOINTS
BRICK
PIER, TYP.
BRICK INFILL,
TYP; STAGGER
JOINTS
BREAK METAL TRIM
RC
STANDING SEAM
METAL ROOF PANELS
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
ALUM. STOREFRONT, TYP.
STANDING SEAM
METAL ROOF PANELS
METAL FASCIA
GUTTER
A512
153B153C 150B 150C 149B 149C
RCRCDSDS DS
ALUM. STOREFRONT
ENTRANCES, TYP.
ALUM. STOREFRONT, TYP.
ALUM. STOREFRONT
ENTRANCES, TYP.
DS
BREAK METAL TRIM
N3.1N4.1N5.1N5.6N8.4N8.6N9.2N9.8 N7.8 N7.05N7.4
27 2726
BRICK
BRICK INFILL, TYP;
STAGGER JOINTS
J JGG G
ALUM. STOREFRONT,
TYP.
33 33 33
BUILDING NUMBER SIGN;
TYPE B5. REFER TO 4/A514
FIRST FLOOR
EL.0' - 0"
124B 125 124C
BOLLARDS
OVERHEAD DOOR
GUTTER
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
HOLLOW MTL DOOR &
FRAME; REFER TO DOOR
SCHEDULE
BREAK METAL TRIM
DOWNSPOUT
INSULATED METAL
PANELS, TYP.
ALUM. STOREFRONT, TYP.
ALUM. STOREFRONT
ENTRANCES, TYP.20
DS
N3.1
BRICK
BRICK INFILL, TYP;
STAGGER JOINTS
MATERIALS LEGEND
BRICK (NEW)
BRICK (EXISTING)
STANDING SEAM METAL ROOF
INSULATED METAL PANELS
WINDOW/STOREFRONT TAG: REFER TO SHEET
A620 FOR TYPES
DOOR TAG: REFER TO SHEET A610 FOR SCHEDULE
COLUMN GRID TAG1
101A
W8
BREAK METAL TRIM
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
BID ALTERNATES
BID ALTERNATE #1 - DROP OFF LOOP (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE DROP-OFF LOOP, DROP ARM GATES
AND ALL ASSOCIATED WORK. REFER TO C002, OTHER CIVIL, LANDSCAPE
AND ELECTRICAL DRAWINGS.
BID ALTERNATE #2 - BRICK CROSSWALK (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE BRICK CROSSWALK ACROSS BATES
STREET AND ALL ASSOCIATED WORK. WORK INCLUDES SAW CUTTING
AND REMOVING EXISTING PAVEMENTS AND INSTALLATION OF NEW
BRICK PAVEMENTS. REFER TO C002, OTHER CIVIL AND LANDSCAPE
DRAWINGS.
BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT
IRON ENCLOSURE INCLUDING GATE AND FOOTINGS; PLAY AREA AND
PLAY STRUCTURE SURFACE MATERIALS, SITE LIGHTING, DRINKING
FOUNTAIN AND ALL ASSOCIATED WORK EXCEPT FOR THE FF&E PLAY
STRUCTURE INCLUDING THE SHADE STRUCTURE AND PLAY AREA
FURNITURE. REFER TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE,
PLUMBING AND ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT
AWARDED THE PLAY STRUCTURE, PLAY AREA SURFACING AND PLAY
AREA FURNITURE WILL NOT BE AWARDED EITHER.
EXTERIOR MATERIAL & COLOR LEGEND
MATERIAL
BRICK
BASIS OF DESIGN PRODUCT & MANUFACTURER COLOR
HANSON - RICHTEX SOUTHERN 355 W/ FLASH CHARLESTON BRICK
MORTAR -- NATURAL COLORED PORTLAND CEMENT
MORTAR AND MATCHES EXISTING MORTAR AS
SELECTED BY GOVERNMENT FROM SAMPLES
CAST STONE -- BEIGE # 37769, FROM FED STD 595B
ALUMINUM STOREFRONT
(IMPACT & BLAST RESISTANT)
EFCO 526 (T) COLOR: DARK BRONZE
FINISH: AA-M10C22 A44
ALUMINUM STOREFRONT
ENTANCES (IMPACT & BLAST
RESISTANT)
EFCO D300 COLOR: DARK BRONZE
FINISH: AA-M10C22 A44
AUTOMATIC SLIDING ENTRANCE
DOORS (BLAST)
STANLEY DURA-SHIELD COLOR: DARK BRONZE
FINISH: AA-M10C22 A44
AUTOMATIC SLIDING ENTRANCE
DOORS (IMPACT)
STANLEY DURA-STORM 2000 COLOR: DARK BRONZE
FINISH: AA-M10C22 A44
ROOF PANEL ULTRA SEAM US-200 PANELS: 18" WIDE
WITH 2" DOUBLE LOCK SEAMS & STIFFNER RIBS
DARK BRONZE
ROOF RE-ROOF PANEL ULTRA SEAM US-200 PANELS: 18" WIDE
WITH 2" DOUBLE LOCK SEAMS & STIFFNER RIBS WITH ROOF
HUGGER. REFER TO SPEC. SECTION
DARK BRONZE
GUTTERS & DOWNSPOUTS TBD DARK BRONZE (MATCH ROOF)
2" INSULATED METAL PANEL CENTRIA, 20" WIDE FORMAWALL DIMENSION SERIES
TEXTURE: SMOOTH
PROFILE: FLAT
REVEAL: 1/8"
ALIGN REVEALS WITH SOFFIT PANEL REVEALS
# 154, DARK BRONZE DURAGUARD PLUS COATING
2" INSULATED METAL PANEL
(FOR SOFFIT)
CENTRIA, 20" WIDE FORMAWALL DIMENSION SERIES
TEXTURE: SMOOTH
PROFILE: FLAT
REVEAL: 1/8"
ALIGN REVEALS OF VERTICAL PANEL WITH REVEALS OF
SOFFIT PANEL
# 154, DARK BRONZE DURAGUARD PLUS COATING
EXTERIOR HOLLOW METAL
DOORS & FRAMES (BLAST &
IMPACT)
-- PT 12; REFER TO A600
EXTERIOR HOLLOW METAL
DOORS & FRAMES
-- PT 12; REFER TO A600
OVERHEAD DOORS (NEW) OVERHEAD DOOR COMPANY
MODEL: STORMTIGHT 625 SERIES, 20 GUAGE
POWDERGUARD WEATHERED FINISH,
DARK BRONZE
CANOPY CEILINGS USG, PARALINE II
MOUNTED ON FLAT CHANNELS
1691 METALLIC GOLD
NON-PERFORATED
GLAZING -- GUARDIAN, BRONZE; REFER TO A620 FOR
GLAZING SCHEDULE
COATING 1 (C1) SHERWIN WILLIAMS
POLYSILOXANE XLE-80 EPOXY SILOXANE
UMBRA: SW 4008
REFER TO SPEC. SECTION 09 97 13.00 40
COATING 2 (C2) SHERWIN WILLIAMS
POLYSILOXANE XLE-80 EPOXY SILOXANE
SILVER BRITE: SW 4091
REFER TO SPEC. SECTION 09 97 13.00 40
METAL FASCIA TBD; 22 GAUGE MINIMUM DARK BRONZE PRE-FINISH TO MATCH ROOF
BREAK METAL TRIM TBD; 22 GAUGE MINIMUM DARK BRONZE PRE-FINISH TO MATCH
STOREFRONT
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A201
EX
TE
RI
OR
B
UI
LD
IN
G
EL
EV
AT
IO
NS
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 1/8" = 1'-0"A102 A201
1 BUILDING ELEVATION - WEST 1
SCALE: 1/8" = 1'-0"A102 A201
2 BUILDING ELEVATION - WEST 2
SCALE: 1/8" = 1'-0"A102 A201
3 BUILDING ELEVATION - EAST 1
SCALE: 1/8" = 1'-0"A102 A201
4 BUILDING ELEVATION - EAST 2
EXTERIOR COLOR SCHEDULE
NOTES
1 MANUFACTURERS NAMES ARE PROVIDED AS THE BASIS OF DESIGN
OR APPROVED EQUAL
2 REFER TO SHEET A620 FOR STOREFRONT ELEVATIONS
3 REFER TO A641 & A642 FOR SIGNAGE
ELEVATION NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES
2 REFER TO A201 FOR EXTERIOR MATERIAL & COLOR SCHEDULE
3 REFER TO A000 FOR ANCILLARY ITEMS (AI) AND BID ALTERNATE
INFORMATION
4 STAGGER MORTAR JOINTS WITH EXISTING BRICK AND HALF BRICK TO
CAMOFLAGE INFILL
NEW CONSTRUCTION
KEYNOTES
16 NEW CONCRETE STAIR AND LANDING, COORDINATE WITH CIVIL.
18 NEW CHILLER - REFER TO MECHANICAL.
20 SPLIT SYSTEM UNITS - REFER TO MECHANICAL.
26 EXHAUST FAN - REFER TO MECHANICAL.
27 ROOF TOP VENTILATOR - REFER TO MECHANICAL
29 EXISTING IMC FENCE TO REMAIN. COORDINATE WITH DEMOLITION
NOTE 38. REPAIR ANY DAMAGE AS A RESULT OF CONSTRUCTION
30 PROVIDE 24" HIGH; REVERSE LIT; CUT METAL LETTERS
CONSTRUCTED OF ALUMINUM; FONT = HELVETICA; TOTAL DEPTH = 5";
LED ILLUMINATION - WHITE. REFER TO 4/A503 FOR DETAILS.
33 EXPOSED STRUCTURAL STEEL TRUSSES, BEAMS, PURLINS, BRACING
AND COLUMNS TO BE FINISHED WITH COATING 2 (C2); REFER TO
EXTERIOR MATERIAL COLOR SCHEDULE, A201 FOR ADDITIONAL
ABCDEHN M
A301
A301
A301
A301
A310
138A 138B
A511
127C
A302
A302
GUTTER
ALUM. STOREFRONT,
TYP.
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
BRICK, TYP.
BRICK PIER, TYP.
CAST STONE, TYP.
ALUM. STOREFRONT
ENTRANCES, TYP.;
REFER TO DOOR
SCHEDULE
OVERHEAD DOOR
BOLLARD
METAL FASCIAINSULATED
METAL PANELS
GUTTER
STANDING SEAM
METAL ROOF PANELS
DS
INSULATED
METAL PANELS
INSULATED
METAL PANELS
NEW MASONRY WALL;
REFER TO PLANS
BRICK INFILL,
TYP; STAGGER
JOINTS
EXT. HOLLOW MTL
DOOR & FRAME
BRICK INFILL, TYP;
STAGGER JOINTS
GUTTER
STANDING SEAM
METAL ROOF PANELS
STANDING SEAM
METAL ROOF PANELS GUTTER
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
BRICK PIER, TYP.
CAST STONE CAP, TYP.
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
METAL FASCIA
STANDING SEAM METAL
ROOF PANELS
BREAK METAL TRIM
20 20 20
RCRC DS DSBOLLARD
Y
NAANM.2NN.1NQ NP NJ.4 NE.8
26 26
33 33
FIRST FLOOR
EL.0' - 0"
A D K L N
A301
A301
A301
A301
165BG
B
B
METAL FASCIA
EXT. HOLLOW METAL
DOOR & FRAME; REFER
TO DOOR SCHEDULE
INSULATED
METAL PANELS
A302
A302
A511
ALUM.
STOREFRONT, TYP.
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
BRICK PIER, TYP.
CAST STONE
CAP, TYP.
OVERHEAD
DOOR
STANDING SEAM METAL
ROOF PANELS
DS
GUTTER
METAL FASCIA
STANDING SEAM
METAL ROOF PANELS
CAST STONE
CAP, TYP.
STANDING SEAM METAL
ROOF PANELS
STANDING SEAM METAL
ROOF PANELS
EXT. HOLLOW METAL
DOOR & FRAME; REFER
TO DOOR SCHEDULE
INSULATED
METAL PANELSGUTTER GUTTER
BRICK PIER, TYP.
METAL FASCIABREAK METAL TRIM
18 20
DSDS DSDSDS RCBRICK
METAL FENCE
NAA NA.4 NA.2 NB.4 NN.1 NQNPNJ.4NE.8NA.9 C.4 NC.8
LIMITS OF BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT IRON
ENCLOSURE INCLUDING GATE AND FOOTINGS; PLAY AREA AND PLAY
STRUCTURE SURFACE MATERIALS, SITE LIGHTING, DRINKING FOUNTAIN AND
ALL ASSOCIATED WORK EXCEPT FOR THE FF&E PLAY STRUCTURE INCLUDING
THE SHADE STRUCTURE AND PLAY AREA FURNITURE. REFER TO C002, OTHER
CIVIL, LANDSCAPE ARCHITECTURE, PLUMBING AND ELECTRICAL DRAWINGS. IF
BID ALTERNATE #3 IS NOT AWARDED THE PLAY STRUCTURE, PLAY AREA
SURFACING AND PLAY AREA FURNITURE WILL NOT BE AWARDED EITHER.
158C 158B 158A
EXISTING BRICK
COLUMN
MATERIALS LEGEND
BRICK (NEW)
BRICK (EXISTING)
STANDING SEAM METAL ROOF
INSULATED METAL PANELS
WINDOW/STOREFRONT TAG: REFER TO SHEET
A620 FOR TYPES
DOOR TAG: REFER TO SHEET A610 FOR SCHEDULE
COLUMN GRID TAG1
101A
W8
BREAK METAL TRIM
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
BID ALTERNATES
BID ALTERNATE #1 - DROP OFF LOOP (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE DROP-OFF LOOP, DROP ARM GATES
AND ALL ASSOCIATED WORK. REFER TO C002, OTHER CIVIL, LANDSCAPE
AND ELECTRICAL DRAWINGS.
BID ALTERNATE #2 - BRICK CROSSWALK (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE BRICK CROSSWALK ACROSS BATES
STREET AND ALL ASSOCIATED WORK. WORK INCLUDES SAW CUTTING
AND REMOVING EXISTING PAVEMENTS AND INSTALLATION OF NEW
BRICK PAVEMENTS. REFER TO C002, OTHER CIVIL AND LANDSCAPE
DRAWINGS.
BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT
IRON ENCLOSURE INCLUDING GATE AND FOOTINGS; PLAY AREA AND
PLAY STRUCTURE SURFACE MATERIALS, SITE LIGHTING, DRINKING
FOUNTAIN AND ALL ASSOCIATED WORK EXCEPT FOR THE FF&E PLAY
STRUCTURE INCLUDING THE SHADE STRUCTURE AND PLAY AREA
FURNITURE. REFER TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE,
PLUMBING AND ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT
AWARDED THE PLAY STRUCTURE, PLAY AREA SURFACING AND PLAY
AREA FURNITURE WILL NOT BE AWARDED EITHER.
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A202
EX
TE
RI
OR
B
UI
LD
IN
G
EL
EV
AT
IO
NS
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 1/8" = 1'-0"A102 A202
1 BUILDING ELEVATION - NORTH
SCALE: 1/8" = 1'-0"A103 A202
2 BUILDING ELEVATION - SOUTH
ELEVATION NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES
2 REFER TO A201 FOR EXTERIOR MATERIAL & COLOR SCHEDULE
3 REFER TO A000 FOR ANCILLARY ITEMS (AI) AND BID ALTERNATE
INFORMATION
4 STAGGER MORTAR JOINTS WITH EXISTING BRICK AND HALF BRICK TO
CAMOFLAGE INFILL
NEW CONSTRUCTION
KEYNOTES
5 EXISTING STEEL SILL(S) TO BE PREPPED AND RE-FINISHED IN
ACCORDANCE WITH SPECIFICATION SECTION - STEEL COATINGS 09
97 13.00 40 FOR MORE PREPARATION AND COATING INFORMATION.
REFER TO BB/BHE01 FOR ADDITIONAL ITEMS REQUIRING FIELD
VERIFICATION. FINISH TO BE COATING 1 (C1)
18 NEW CHILLER - REFER TO MECHANICAL.
19 CHAIN LINK FENCE ENCLOSURE - REFER TO CIVIL FOR SIZES AND
DETAILS.
20 SPLIT SYSTEM UNITS - REFER TO MECHANICAL.
26 EXHAUST FAN - REFER TO MECHANICAL.
27 ROOF TOP VENTILATOR - REFER TO MECHANICAL
33 EXPOSED STRUCTURAL STEEL TRUSSES, BEAMS, PURLINS, BRACING
AND COLUMNS TO BE FINISHED WITH COATING 2 (C2); REFER TO
EXTERIOR MATERIAL COLOR SCHEDULE, A201 FOR ADDITIONAL
EXISTING ROOF DECK
EL.12' - 3"
A D NL.8 M
A301
A301
A301
A301
COVERED
CANOPY
AREA
VESTIBULE
CENTRAL
LOBBY
DEPARTURE
GATE 2
A A
A313
A302
A302
A311
A312
A 149AC C C
A551
TYP.
123 33 3
1 1/2" 12"
1 1/2" 12"
NAA NM.2 NN.1 NQNJ.4NE.8 NL.1NK.9NE.4NA.9 NC.8
CLERESTORY
27 2626
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
3 4 5 6 8 9 10 117 7.9 9.3 9.7
A301
A301
A301
A301
176 165A 159A 159B
BAGGAGE
BUILD UP
DISPATCH
CENTRAL
LOBBY
WOMEN
MEN
MECHANICAL
LOST &
FOUND
CORRIDOR
A302
A302
A302
A302
A312
T
A551
TYP.
1 1/2" 12"
N7.8N7.05
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
DEKLN L.8M
A301
A301
A301
A301
CENTRAL
LOBBY
DEPARTURE
GATE 2
VESTIBULE
COVERED
CANOPY
AREA
A511
A302
A302
153A G
13 13
A551
TYP.
NAANA.4NN.1NQ NP NJ.4 NE.8NL.1 NK.9 NE.4 NA.9C.4NC.8 NC.5
CLERESTORY
LIMITS OF BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT IRON ENCLOSURE
INCLUDING GATE AND FOOTINGS; PLAY AREA AND PLAY STRUCTURE SURFACE
MATERIALS, SITE LIGHTING, DRINKING FOUNTAIN AND ALL ASSOCIATED WORK EXCEPT
FOR THE FF&E PLAY STRUCTURE INCLUDING THE SHADE STRUCTURE AND PLAY AREA
FURNITURE. REFER TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE, PLUMBING AND
ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT AWARDED THE PLAY STRUCTURE,
PLAY AREA SURFACING AND PLAY AREA FURNITURE WILL NOT BE AWARDED EITHER.
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
123456891011 5.2
A301
A301
A301
A301
CORRIDOR
CENTRAL
LOBBY
FLIGHT
CHECK-IN
COUNTER
DISPATCH
BAGGAGE
BUILD UP
134 127D 124B 125
124C
A310
A511
A302
A302
A302
A302
101B172B
C
11 10 A551
TYP.
1 1/2" 12" 1 1/2"
12"
N7.1N7.8 N7.05
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
BID ALTERNATES
BID ALTERNATE #1 - DROP OFF LOOP (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE DROP-OFF LOOP, DROP ARM GATES
AND ALL ASSOCIATED WORK. REFER TO C002, OTHER CIVIL, LANDSCAPE
AND ELECTRICAL DRAWINGS.
BID ALTERNATE #2 - BRICK CROSSWALK (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE BRICK CROSSWALK ACROSS BATES
STREET AND ALL ASSOCIATED WORK. WORK INCLUDES SAW CUTTING
AND REMOVING EXISTING PAVEMENTS AND INSTALLATION OF NEW
BRICK PAVEMENTS. REFER TO C002, OTHER CIVIL AND LANDSCAPE
DRAWINGS.
BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT
IRON ENCLOSURE INCLUDING GATE AND FOOTINGS; PLAY AREA AND
PLAY STRUCTURE SURFACE MATERIALS, SITE LIGHTING, DRINKING
FOUNTAIN AND ALL ASSOCIATED WORK EXCEPT FOR THE FF&E PLAY
STRUCTURE INCLUDING THE SHADE STRUCTURE AND PLAY AREA
FURNITURE. REFER TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE,
PLUMBING AND ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT
AWARDED THE PLAY STRUCTURE, PLAY AREA SURFACING AND PLAY
AREA FURNITURE WILL NOT BE AWARDED EITHER.
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A301
B
UI
LD
IN
G
SE
C
TI
ON
S
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 1/8" = 1'-0"A102 A301
1 BUILDING SECTION
SCALE: 1/8" = 1'-0"A102 A301
2 BUILDING SECTION
SCALE: 1/8" = 1'-0"A102 A301
3 BUILDING SECTION
SCALE: 1/8" = 1'-0"A102 A301
4 BUILDING SECTION
NEW CONSTRUCTION
KEYNOTES
3 BAGGAGE HANDLING EQUIPMENT (BHE) TO BE PROVIDED AND
INSTALLED UNDER SEPERATE CONTRACT, SHALL BE COORDINATED
BY CONTRACTOR. REFER TO MEP DRAWINGS FOR REQUIREMENTS
WHICH ARE PART OF THE BASE BID AND IN THE GENERAL
CONTRACTORS SCOPE OF WORK.
10 PHONE CARD MACHINE (PROVIDED AND INSTALLED BY OTHERS)
LOCATIONS INDICATED FOR COORDINATION - REFER TO ELECTRICAL
FOR REQUIREMENTS WHICH ARE PART OF THE BASE BID AND IN THE
GENERAL CONTRACTORS SCOPE OF WORK.
11 ATM (PROVIDED AND INSTALLED BY OTHERS) LOCATIONS INDICATED
FOR COORDINATION - REFER TO ELECTRICAL FOR REQUIREMENTS
WHICH ARE PART OF THE BASE BID AND IN THE GENERAL
CONTRACTORS SCOPE OF WORK.
12 FOLDING PANEL PARTITION SHALL BE PROVIDED AND INSTALLED BY
CONTRACTOR - REFER TO STRUCTURAL, ELECTRICAL AND
SPECIFICATION SECTION 10 22 39 FOLDING PANEL PARTITION.
13 SUSPENDED 3-DIMENSIONAL CURVED SYSTEM IS PART OF
FF&E-ANCILLARY ITEM #1; REFER TO ANCILLARY ITEM #1 NOTES ON
A410 & A411 - REFER TO SPECIFICATION SECTION 09 54 00. BASIS OF
DESIGN IS TWO-DIRECTIONAL USG CURVATURA SYSTEM WITH 2'x 2'
PANELS WITH 9/16" SUSPENSION SYSTEM WITH 5/32" REVEAL.
20 SPLIT SYSTEM UNITS - REFER TO MECHANICAL.
23 LINEAR METAL CEILING EXTERIOR.
24 LINEAR METAL CEILING INTERIOR.
26 EXHAUST FAN - REFER TO MECHANICAL.
27 ROOF TOP VENTILATOR - REFER TO MECHANICAL
SECTION NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES
2 REFER TO A201 FOR EXTERIOR MATERIAL & COLOR SCHEDULE
3 REFER TO A000 FOR ANCILLARY ITEMS (AI) AND BID ALTERNATE
INFORMATION
EXISTING ROOF DECK
EL.12' - 3"
3 4 5 6 8 9 10 117 9.3 9.7
A301
A301
A301
A301
A311
A311
A302
A302
A302
A302
149BG 150A 153B 153C 156A
FE-1FE-1
BAGGAGE
BREAKDOWN
BAGGAGE
CLAIM
DEPARTURE/ARRIVAL
GATE 3
SECURE
GATE
CORRIDOR
DEPARTURE
GATE 1
SPEC. CAT
LOUNGE
SHOWER/
CHANGING
ROOM
1 1/2" 12"
1 1/2" 12"
N7.8N7.05
A514
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
A B D E F K L NG L.8 M
A301
A301
A301
A301
A302
A302
A511 A314
A312
156C 156B162163170
ARRIVAL
WAITING
CORRIDOR
PLAY
ROOM
BAGGAGE
CLAIM
1 1/2" 12"
NAA NA.4 NN.1 NQNPNJ.4NE.8 NL.1NA.9 C.4 NC.8NC.5
LIMITS OF BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT
IRON ENCLOSURE INCLUDING GATE AND FOOTINGS; PLAY AREA AND PLAY
STRUCTURE SURFACE MATERIALS, SITE LIGHTING, DRINKING FOUNTAIN
AND ALL ASSOCIATED WORK EXCEPT FOR THE FF&E PLAY STRUCTURE
INCLUDING THE SHADE STRUCTURE AND PLAY AREA FURNITURE. REFER
TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE, PLUMBING AND
ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT AWARDED THE PLAY
STRUCTURE, PLAY AREA SURFACING AND PLAY AREA FURNITURE WILL
NOT BE AWARDED EITHER.
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
ABDEK HN L.8M
A301
A301
A301
A301
A302
A302
SPEC. CAT
LOUNGE
UNISEX
BUSINESS
CENTER
BAGGAGE
BUILD UP
BREAK
ROOM
TRAINING
OIC OFFICE
READING
ROOM
GAME
ROOM
146 145 127A
1 1/2" 12"
NAANM.2NN.1NQ NP NJ.4 NE.8NL.1
Y
NOTE:
NOT ALL KEYNOTES ARE USED ON ALL SHEETS. THE INTENT OF THE
WORK REMAINS. REFER TO A000 FOR MASTER LIST.
BID ALTERNATES
BID ALTERNATE #1 - DROP OFF LOOP (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE DROP-OFF LOOP, DROP ARM GATES
AND ALL ASSOCIATED WORK. REFER TO C002, OTHER CIVIL, LANDSCAPE
AND ELECTRICAL DRAWINGS.
BID ALTERNATE #2 - BRICK CROSSWALK (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE BRICK CROSSWALK ACROSS BATES
STREET AND ALL ASSOCIATED WORK. WORK INCLUDES SAW CUTTING
AND REMOVING EXISTING PAVEMENTS AND INSTALLATION OF NEW
BRICK PAVEMENTS. REFER TO C002, OTHER CIVIL AND LANDSCAPE
DRAWINGS.
BID ALTERNATE #3 - PLAY AREA (MINOR CONSTRUCTION)
THIS BID ALTERNATE INCLUDES THE PLAY AREA, BRICK AND WROUGHT
IRON ENCLOSURE INCLUDING GATE AND FOOTINGS; PLAY AREA AND
PLAY STRUCTURE SURFACE MATERIALS, SITE LIGHTING, DRINKING
FOUNTAIN AND ALL ASSOCIATED WORK EXCEPT FOR THE FF&E PLAY
STRUCTURE INCLUDING THE SHADE STRUCTURE AND PLAY AREA
FURNITURE. REFER TO C002, OTHER CIVIL, LANDSCAPE ARCHITECTURE,
PLUMBING AND ELECTRICAL DRAWINGS. IF BID ALTERNATE #3 IS NOT
AWARDED THE PLAY STRUCTURE, PLAY AREA SURFACING AND PLAY
AREA FURNITURE WILL NOT BE AWARDED EITHER.
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A302
B
UI
LD
IN
G
SE
C
TI
ON
S
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 1/8" = 1'-0"A102 A302
1 BUILDING SECTION
SCALE: 1/8" = 1'-0"A103 A302
2 BUILDING SECTION
SCALE: 1/8" = 1'-0"A102 A302
3 BUILDING SECTION
NEW CONSTRUCTION
KEYNOTES
2 VENDING MACHINES PROVIDED AND INSTALLED BY OTHERS. REFER
TO ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL
REQUIREMENTS.
3 BAGGAGE HANDLING EQUIPMENT (BHE) TO BE PROVIDED AND
INSTALLED UNDER SEPERATE CONTRACT, SHALL BE COORDINATED
BY CONTRACTOR. REFER TO MEP DRAWINGS FOR REQUIREMENTS
WHICH ARE PART OF THE BASE BID AND IN THE GENERAL
CONTRACTORS SCOPE OF WORK.
4 SECURITY SCANNING EQUIPMENT (SSE) TO BE PROVIDED AND
INSTALLED UNDER SEPERATE CONTRACT AND SHALL BE
COORDINATED BY GENERAL CONTRACTOR. REFER TO MEP
DRAWINGS FOR REQUIREMENTS, INCLUDING ALTERNATE LOCATION,
WHICH ARE PART OF THE BASE BID AND IN THE GENERAL
CONTRACTORS SCOPE OF WORK.
23 LINEAR METAL CEILING EXTERIOR.
26 EXHAUST FAN - REFER TO MECHANICAL.
27 ROOF TOP VENTILATOR - REFER TO MECHANICAL
33 EXPOSED STRUCTURAL STEEL TRUSSES, BEAMS, PURLINS, BRACING
AND COLUMNS TO BE FINISHED WITH COATING 2 (C2); REFER TO
EXTERIOR MATERIAL COLOR SCHEDULE, A201 FOR ADDITIONAL
INFORMATION.
SECTION NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES
2 REFER TO A201 FOR EXTERIOR MATERIAL & COLOR SCHEDULE
EXISTING ROOF DECK
EL.12' - 3"
STEEL BEAM; REFER
TO STRUCTURAL
CEILING REFER TO
FINISH SCHEDULE
AIR SPACE (MATCH EXISTING)
NEW BRICK VENEER TO MATCH EXISTING, REFER TO
STRUCTURAL FOR REINFORCING AND LINTEL INFORMATION.
INSULATED, VERTICAL METAL WALL
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
RETRO FIT ZEE PURLINS
RIGID INSULATION;
STAGGER SEAMS BREAK METAL; (PRE-
FINISHED TO MATCH ROOF
PANELS) WRAPPED FASCIA
P.T. WD BLOCKING
CONCRETE SLAB; REFER TO
STRUCTURAL
CONCRETE FOOTING;
REFER TO STRUCTURAL.
METAL STUD WITH BATT
INSULATION
GYP BD (MOLD AND
MOISTURE RESISTANT)
METAL DECK; REFER
TO STRUCTURAL
METAL DECK; REFER
TO STRUCTURAL
INSULATED METAL SOFFIT PANELS; REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
SOFFIT EXTRUSION TRIM BY METAL
WALL PANEL MANUFACTURER (FINISH
TO MATCH INSULATED METAL PANELS)
CMU; REFER TO STRUCTURAL
FOR REINFORCING AND LINTEL
INFORMATION
STANDING SEAM METAL ROOF PANELS
A512
SIM
A512
SIM
DRIP EDGE; PRE-FINISHED
TO MATCH ROOF PANELS
GUTTER
METAL FLASHING DRIP EDGE;
PRE-FINISHED TO MATCH STANDING
SEAM METAL ROOF PANELS
METAL PURLIN; REFER
TO STRUCTURAL
METAL STUD FRAMING;
REFER TO DETAILS ON A512
STEEL TUBE; REFER
TO STRUCTURAL
FLUID APPLIED, VAPOR PERMEABLE,
WATER RESISTANT/AIR BARRIER
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
CMU; REFER TO STRUCTURAL
FOR REINFORCING AND
LINTEL INFORMATION
AIR SPACE (MATCH EXISTING)
BRICK VENEER, MASONRY. REFER TO STRUCTURAL
FOR REINFORCING AND LINTEL INFORMATION
CONCRETE SLAB; REFER
TO STRUCTURAL
CONCRETE FOOTING;
REFER TO STRUCTURAL
INSULATED, VERTICAL METAL WALL
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
INSULATED METAL SOFFIT PANELS; REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
SOFFIT EXTRUSION TRIM BY METAL
WALL PANEL MANUFACTURER (FINISH
TO MATCH INSULATED METAL PANELS)
METAL STUD WITH BATT
INSULATION
GYP BD (MOLD AND
MOISTURE RESISTANT)
STEEL BEAM; REFER
TO STRUCTURAL
ZEE PURLIN
RIGID INSULATION;
STAGGER SEAMS
BREAK METAL; (PRE-FINISHED
TO MATCH ROOF PANELS)
WRAPPED FASCIA
METAL DECK; REFER
TO STRUCTURAL P.T. WD BLOCKING
STANDING SEAM
METAL ROOF PANELS
DOWNSPOUT, TYP; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
DOWNSPOUT - REFER TO CIVIL
FOR CONTINUATION
A512
SIM
A512
SIM
DRIP EDGE; PRE-FINISHED
TO MATCH ROOF PANELS
GUTTER
METAL FLASHING DRIP EDGE;
PRE-FINISHED TO MATCH STANDING
SEAM METAL ROOF PANELS
METAL DECK; REFER
TO STRUCTURAL
METAL PURLIN; REFER
TO STRUCTURAL
STEEL TUBE; REFER
TO STRUCTURAL
METAL STUD FRAMING;
REFER TO DETAILS ON A512
FLUID APPLIED, VAPOR PERMEABLE,
WATER RESISTANT/AIR BARRIER
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
A
EXISTING FRAMING @ 13'-6"
O.C. (FIELD VERIFY SPACING)
RETRO FIT ZEE PURLIN
BREAK METAL; (PRE-
FINISHED TO MATCH ROOF
PANELS) WRAPPED FASCIA
P.T. WD BLOCKING
SHOTCRETE WALL; REFER
TO STRUCTURAL.
EXISTING CONCRETE SLAB;
REFER TO STRUCTURAL.
METAL STUD WITH BATT
INSULATION
GYP BD (MOLD AND
MOISTURE RESISTANT)
EXISTING METAL DECK
EXISTING STANDING SEAM
METAL ROOF SYSTEM
EXISTING STRUCTURE;
REFER TO STRUCTURAL
CEILING REFER TO
FINISH SCHEDULE
EXISTING BAR JOIST
EL. 10' - 0"
INSULATED METAL SOFFIT PANELS; REFER
TO EXTERIOR MATERIAL & COLOR SCHEDULE
EXISTING CMU; REFER
TO STRUCTURAL.
EXISTING BRICK VENEER
A512
A512
INSULATED VERTICAL METAL WALL
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
STANDING SEAM METAL
ROOF PANELS
RIGID INSULATION;
STAGGER SEAMS
DRIP EDGE; PRE-FINISHED
TO MATCH ROOF PANELS
GUTTER
EXISTING
METAL STUD FRAMING;
REFER TO DETAILS ON A512
METAL FLASHING DRIP
EDGE; PRE-FINISHED TO
MATCH STANDING SEAM
METAL ROOF PANELS
EL. 9' - 6 1/2"
EL. 9' - 4"
TOP OF GLAZING
SOFFIT EXTRUSION TRIM BY METAL
WALL PANEL MANUFACTURER (FINISH
TO MATCH INSULATED METAL PANELS)
2'-4"
METAL STUD FRAMING;
REFER TO DETAILS ON A512
WALL SECTION LEGEND
& SYMBOLS
BRICK
CMU
COLUMN GRID TAG
SPOT ELEVATION
CENTERLINE
REVISION TAG
BATT INSULATION
METAL STUD
ROOF SLOPE
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DIVIDED INTO TWO SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION)
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A310
W
AL
L
SE
C
TI
ON
S
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
99SCALE: 1" = 1'-0"A102 A310
2 WALL SECTION @ NEW 8" BLOCK/BRICK WALL
SCALE: 1" = 1'-0"A301 A310
3 WALL SECTION @ NEW 12" BLOCK/BRICK WALL
SCALE: 1" = 1'-0"A102 A310
1 WALL SECTION @ EXIST. BLOCK/BRICK
SECTION NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES
2 REFER TO A201 FOR EXTERIOR MATERIAL & COLOR SCHEDULE
EXISTING ROOF DECK
EL.12' - 3"
M
INSULATED VERTICAL METAL WALL
PANEL; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
INSULATED METAL SOFFIT PANEL; REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
SOFFIT EXTRUSION TRIM BY METAL
WALL PANEL MANUFACTURER (FINISH
TO MATCH INSULATED METAL PANELS)
EXISTING METAL DECK
STEEL BEAM; REFER
TO STRUCTURAL
RETRO FIT ZEE PURLIN
BREAK METAL; (PRE-FINISH TO
MATCH ROOF PANELS)
WRAPPED FASCIA
EXISTING STANDING SEAM
METAL ROOF SYSTEM
EXISTING STRUCTURE;
REFER TO STRUCTURAL P.T. WD BLOCKING
STEEL ANGLE; REFER
TO STRUCTURAL
GYPSUM BOARD SOFFIT
METAL STUD FRAMING
STOREFRONT; REFER TO
A620 FOR ELEVATION BREAK METAL TRIM
ACOUSTIC CEILING TILE
STEEL TUBE; REFER TO
STRUCTURAL. FINISHED TO BE C2;
REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
STANDING SEAM ROOF
PANELS ON CANOPY
SLOPE AWAY
FROM BLDG
FINISH FLOOR; REFER TO
FINISH AND COLOR SCHEDULE
EXISTING CONCRETE SLAB
SIDEWALK; REFER TO CIVIL
EXISTING FOUNDATION WALL;
REFER TO STRUCTURAL
EXISTING CONCRETE FOOTING;
REFER TO STRUCTURAL
A621
A621
GUTTER
9'- 4"
A512
SIM
A512
SIM
STANDING SEAM METAL
ROOF PANELS
RIGID INSULATION;
STAGGER SEAMS
EXISTING
DRIP EDGE; PRE-FINISHED
TO MATCH ROOF PANELS
METAL FLASHING DRIP EDGE; PRE-
FINISHED TO MATCH STANDING
SEAM METAL ROOF PANELS
NM.2
EXISTING FRAMING @ 13'-6"
O.C. (FIELD VERIFY SPACING)
METAL STUD FRAMING;
REFER TO DETAILS ON A512
LINEAR METAL PAN CANOPY
CEILING; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
DEPARTURE
GATE 1
EXISTING ROOF DECK
EL.12' - 3"
N
INSULATED VERTICAL METAL WALL PANEL; REFER
TO EXTERIOR MATERIAL & COLOR SCHEDULE
INSULATED METAL SOFFIT PANEL;
REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
SOFFIT EXTRUSION TRIM BY METAL
WALL PANEL MANUFACTURER (FINISH
TO MATCH INSULATED METAL PANELS)
EXISTING METAL DECK
STEEL BEAM; REFER TO STRUCTURAL
RETRO FIT ZEE PURLIN
BREAK METAL WRAPPED FASCIA;
PRE-FINISH TO MATCH ROOF PANELS
EXISTING STANDING SEAM
METAL ROOF SYSTEM
EXISTING STRUCTURE;
REFER TO STRUCTURAL
P.T. WD BLOCKING
GYPSUM BOARD SOFFIT
METAL STUD FRAMING
STOREFRONT, REFER TO
A620 FOR ELEVATION
BREAK METAL TRIM; FINISH TO
MATCH STOREFRONT SYSTEM
CEILING; REFER TO
FINISH SCHEDULE
STEEL TUBE BEAM; REFER TO
STRUCTURAL. FINISH TO BE C2; REFER TO
EXTERIOR MATERIAL & COLOR SCHEDLUE
SLOPE AWAY
FROM BLDG
FINISH FLOOR; REFER TO
FINISH & COLOR SCHEDULE
EXISTING CONCRETE SLAB
SIDEWALK; REFER TO CIVIL
EXISTING FOUNDATION WALL;
REFER TO STRUCTURAL
EXISTING CONCRETE FOOTING;
REFER TO STRUCTURAL
MASONRY COLUMN;
REFER TO A502
STEEL BEAM; REFER
TO STRUCTURAL
LINEAR METAL PAN CANOPY
CEILING; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
A512
SIM
STANDING SEAM METAL
ROOF PANELS
RIGID INSULATION;
STAGGER SEAMS
EXISTING
DRIP EDGE; PRE-FINISH
TO MATCH ROOF PANELS
METAL FLASHING DRIP EDGE; PRE-
FINISHED TO MATCH STANDING
SEAM METAL ROOF PANELS
GUTTER
NN.1
EXISTING FRAMING @ 13'-6" O.C.
(FIELD VERIFY SPACING)
METAL STUD FRAMING;
REFER TO DETAILS ON A512
DEPARTURE/ARRIVAL
GATE 3
A512
SIM
EXISTING ROOF DECK
EL.12' - 3"
N
INSULATED, VERTICAL METAL WALL
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
INSULATED METAL SOFFIT PANELS; REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
SOFFIT EXTRUSION TRIM BY METAL WALL
PANEL MANUFACTURER (FINISH TO MATCH
INSULATED METAL PANELS)
ZEE PURLIN (INSULATION BACKSTOP)
EXISTING STANDING SEAM
METAL ROOF SYSTEM
EXISTING STRUCTURE,
REFER TO STRUCTURAL.
STEEL ANGLE, REFER
TO STRUCTURAL.
GYPSUM BOARD SOFFIT
METAL STUD FRAMING
STOREFRONT, REFER TO
A620 FOR ELEVATION
CEILING; REFER TO
FINISH SCHEDULE
FINISH FLOOR; REFER TO
FINISH AND COLOR SCHEDULE
EXISTING CONCRETE SLAB
SIDEWALK; REFER TO CIVIL
EXISTING FOUNDATION WALL;
REFER TO STRUCTURAL
EXISTING CONCRETE FOOTING;
REFER TO STRUCTURAL
A622
INSULATION BETWEEN CANOPY
RAFTERS; REFER TO STRUCTURAL
FOR RAFTER SIZES AND SPACING
STANDING SEAM METAL ROOF PANELS
MASONRY COLUMN;
REFER TO A502
TUBE STEEL COLUMN; REFER TO
STRUCTURAL. FINISH TO BE C2; REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
LINEAR METAL PAN CANOPY
CEILING; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
3 5/8" METAL STUD FRAMING
ATTACH TO EXISTING FRAMING
BRACE AS REQUIRED
BREAK METAL TRIM; FINISH TO
MATCH STOREFRONT SYSTEM
BATT INSULATION A512
SIM
STEEL TUBE TRUSS; REFER TO
STRUCTURAL. FINISH TO BE C2;
REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
NN.1
EXISTING FRAMING @ 13'-6"
O.C. (FIELD VERIFY SPACING)
METAL STUD FRAMING;
REFER TO DETAILS ON A512
BACK-LIT SIGNAGE; REFER TO
BUILDING ELEVATION 3/A201
DEPARTURE
GATE 2
WALL SECTION LEGEND
& SYMBOLS
BRICK
CMU
COLUMN GRID TAG
SPOT ELEVATION
CENTERLINE
REVISION TAG
BATT INSULATION
METAL STUD
ROOF SLOPE
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DIVIDED INTO TWO SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION)
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A311
W
AL
L
SE
C
TI
ON
S
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
100SCALE: 1" = 1'-0"A102 A311
1 WALL SECTION @ DEPARTURE GATE 1
SCALE: 1" = 1'-0"A103 A311
3 WALL SECTION @ DEPARTURE/ARRIVAL GATE 3
SCALE: 1" = 1'-0"A301 A311
2 WALL SECTION @ DEPARTURE GATE 2
SECTION NOTES
1 REFER TO G111 FOR GENERAL PROJECT NOTES
2 REFER TO A201 FOR EXTERIOR MATERIAL & COLOR SCHEDULE
EXISTING ROOF DECK
EL.12' - 3"
CMU, REFER TO STRUCTURAL FOR
REINFORCING AND LINTEL INFORMATION
BOLLARD, BEYOND
CONCRETE SLAB;
REFER TO STRUCTURAL
CONCRETE FOOTING;
REFER TO STRUCTURAL
3 5/8" METAL STUD
INSULATED, VERTICAL METAL WALL
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
INSULATED METAL SOFFIT PANELS;
REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
SOFFIT EXTRUSION TRIM BY METAL
WALL PANEL MANUFACTURER (FINISH
TO MATCH INSULATED METAL PANELS)
STEEL BEAM; REFER
TO STRUCTURAL
STANDING SEAM METAL ROOF
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
ZEE PURLIN
BREAK METAL; (PRE-FINISHED
TO MATCH ROOF PANELS)
WRAPPED FASCIA
METAL DECK; REFER
TO STRUCTURAL
P.T. WD BLOCKING
STEEL BEAM; REFER TO STRUCTURAL
A612
RIGID INSULATION; STAGGER SEAMS
GUTTER
A512
SIM
A512
SIM
DRIP EDGE; PRE-FINISHED
TO MATCH ROOF PANELS
METAL FLASHING DRIP EDGE; PRE-
FINISHED TO MATCH STANDING
SEAM METAL ROOF PANELS
ROLL-UP DOOR MOTOR
ROLL-UP OVERHEAD DOOR;
REFER TO DOOR SCHEDULE
ROLL-UP DOOR HOOD
STEEL PLATE; REFER TO STRUCTURAL
STEEL TUBE; REFER
TO STRUCTURAL
BREAK METAL TRIM; FINISH TO MATCH
STOREFRONT SYSTEM
METAL PURLINS; REFER
TO STRUCTURAL
METAL STUD FRAMING; REFER
TO DETAILS ON A512
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
SHOTCRETE; REFER TO
STRUCTURAL
METAL STUD/SHOTCRETE/CMU
WALL; REFER TO PLAN(S) AND
WALL TYPES
STEEL CHANNEL; REFER
TO STRUCTURAL
EXISTING CMU WALL
EXISTING BAR JOIST
EXISTING FILLER BLOCK
EXISTING METAL DECK
DIRECTION SWITCH
EXISTING BAR JOIST
GYP BD SOFFIT, TYP.
ACT CEILING; REFER TO
REFLECTED CEILING
PLAN FOR HEIGHT
STOREFRONT HEAD
STOREFRONT SILL
EXISTING CONCRETE SLAB
GLAZING
STOREFRONT MULLION
EXISTING FOOTING
A623
A623
A624
Sim
FIRST FLOOR
EL.0' - 0"
EXISTING ROOF DECK
EL.12' - 3"
9'- 6"
SUPPORT BEAM; REFER TO 8/S611
ELECTRICALLY POWERED
FOLDING PARTITION. BASIS OF
DESIGN: MODERNFOLD FOLDING
PARTITION 933E
GYPSUM WALL BOARD
METAL STUD FRAMING
MOUNT HEAD OF DOOR FLUSH
WITH GYP BD SOFFIT
FLOATING SEAL PROVIDE 3"
OPERATING CLEARANCE
CARPET; REFER TO FINISH AND
COLOR SCHEDULE(S), A600
3" PIPE; REFER TO STRUCTURAL
EXISTING METAL DECK
STEEL PLATE; REFER TO…