Attachment__2_-_Drawings_dated_30_October_2013_-_Part_10.pdf

PDF 4 MB Posted

Attached to
Add/Repair Passenger Terminal, Bldg. 164
Solicitation number
FA4418-15-R-0009
Issued by

About this file

Attachment 2 - Drawings dated 30 October 2013 - Part 10 for Solicitation FA4418-16-R-0002 Add/Repair Passenger Terminal Bldg 164.

View the file

Other files

File Type Posted
Attachment__15_-_Spec_Section_01_32_16_00_20_dated_30_October_2013.pdf PDF
Attachment__14_-_Addendum__3_dated_9_February_2016.pdf PDF
FA4418-16-R-0002-0003_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__3.pdf PDF
FA4418-16-R-0002_-_Add_Repair_Passenger_Terminal _Bldg_164_-_Questions_and_Answers.pdf PDF
FA4418-16-R-0002-0001_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__2.pdf PDF
FA4418-16-R-0002_-_Pre-proposal_Site_Visit_Minutes_-_Passenger_Terminal.pdf PDF
Attachment__1_-_Pre-proposal_Site_Visit_Record_of_Attendance.pdf PDF
Attachment__2_-_Pre-proposal_Site_Visit_Presentation.pdf PDF
Attachment__11_-_Asbestos_ _Lead_Report_dated_10_October_2012.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_2.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_1.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_3.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_5.pdf PDF
FA4418-16-R-0002-0001_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__1.pdf PDF
Attachment__12_-_Passenger_Terminal_OS-SWPPP_dated_2_October_2013.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_4.pdf PDF
FA4418-16-R-0002_-_Pre-proposal_Conference_Transportation_Instructions.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_3.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_13.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_7.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_1.pdf PDF
Attachment__4_-_SID_Schedule_dated_30_October_2013.pdf PDF
Attachment__6_-_Green_Procurement_Form_dated_15_July_2015.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_2.pdf PDF
Attachment__3_-_FF E_Schedule_dated_30_October_2013.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_8.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_14.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_11.pdf PDF
Attachment__10_-_Addendum__2_dated_10_November_2015.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_6.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_12.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_2.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_3.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_9.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_4.pdf PDF
Attachment__5_-_Wage_Determination_dated_22_May_2015.pdf PDF
FA4418-16-R-0002_Add_Repair_Passenger_Terminal _Bldg_164.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_5.pdf PDF
Attachment__7_-_Submittal_Register_dated_14_March_2014.pdf PDF
Attachment__9_-_Spec_Section_01_32_17_00_20_NAS_dated_30_October_2013.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_1.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_15.pdf PDF
Attachment__8_-_Addendum__1_dated_17_September_2014.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS WALL: TILE PATTERN 1

PTDWR

EHD

PT2

4'- 0"

2'- 0"

3'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

MENS

THIS WALL: TILE PATTERN 1

PTDWR

MG

SDW

PT2

A572

EL. 0' - 0"

EL. 9' - 0"

EL. 8' - 0"

9'- 0"

4'- 0"

2'- 0"

3'- 0"

3'- 0"

2'- 0"

4'- 0"

9'- 0"

THIS WALL: TILE PATTERN 1

MG

SDW

TP1

TTD

A701

SIM PT2

A572

EL. 0' - 0"

EL. 9' - 0"

THIS WALL: TILE PATTERN 1

PT2

TP1

A572

4'- 0"

2'- 0"

3'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

THIS WALL: TILE PATTERN 1

PTDWR

EHD

WOMENS

PT2

3'- 0"

2'- 0"

4'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

THIS WALL: TILE PATTERN 1

TP1

WOMENS

PT2

A572

4'- 0"

2'- 0"

3'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

EL. 8' - 0"

THIS WALL: TILE PATTERN 1

TTD TTD

MG

SDW

SNDL SNDL

A701

SIM

PT2 WOMENS

TP1

A572

4'- 0"

2'- 0"

3'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

THIS WALL: TILE PATTERN 1

MG

SDW PTDWR

PT2

WOMENS

A572

3'- 0"

2'- 0"

4'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

THIS WALL: TILE PATTERN 2

BCH1

4'- 0"

2'- 0"

3'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

FG

THIS WALL: TILE PATTERN 2

130 SHOWER; REFER

TO PLUMBING

3'- 0"

2'- 0"

4'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

THFG

BCH1

SDW

SDW

CWT10

EL. 9' - 0"

2'- 8"

6'- 4"

9'- 0"

TH

SHOWER; REFER

TO PLUMBING

THIS WALL: TILE PATTERN 2

SHOWER; REFER

TO PLUMBING

4'- 0"

2'- 0"

3'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

TH FG

BCH1

THIS WALL: TILE PATTERN 2

BCH1

3'- 0"

2'- 0"

4'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

FG

THIS WALL: TILE PATTERN 2

4'- 0"

2'- 0"

3'- 0"

9'- 0"

6'- 4"

SHOWER; REFER

TO PLUMBING

EL. 0' - 0"

EL. 9' - 0"

FG TH

BCH1

SHOWER; REFER

TO PLUMBING

CWT10

EL. 0' - 0"

9'- 0"

6'- 4"

2'- 8"

TH

EL. 9' - 0"

SDW

THIS WALL: TILE PATTERN 2

132SHOWER; REFER

TO PLUMBING

3'- 0"

2'- 0"

4'- 0"

9'- 0"

EL. 0' - 0"

EL. 9' - 0"

TH FG

BCH1

SDW

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A408

EN

LA

RG

ED

E

LE

VA

TI

ON

S R

ES

TR

OO

M S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A403 A408

1 INT. ELEV. - MEN 129

SCALE: 1/2" = 1'-0"A403 A408

2 INT. ELEV. - MEN 129

SCALE: 1/2" = 1'-0"A403 A408

3 INT. ELEV. - MEN 129

SCALE: 1/2" = 1'-0"A403 A408

4 INT. ELEV. - MEN 129

SCALE: 1/2" = 1'-0"A403 A408

9 INT. ELEV. - WOMEN 131

SCALE: 1/2" = 1'-0"A403 A408

10 INT. ELEV. - WOMEN 131

SCALE: 1/2" = 1'-0"A403 A408

11 INT. ELEV. - WOMEN 131

SCALE: 1/2" = 1'-0"A403 A408

12 INT. ELEV. - WOMEN 131

SCALE: 1/2" = 1'-0"A403 A408

5 INT. ELEV. - SHOWER 130

SCALE: 1/2" = 1'-0"A403 A408

6 INT. ELEV. - SHOWER 130

SCALE: 1/2" = 1'-0"A403 A408

7 INT. ELEV. - SHOWER 130

SCALE: 1/2" = 1'-0"A403 A408

8 INT. ELEV. - SHOWER 130

SCALE: 1/2" = 1'-0"A403 A408

13 INT. ELEV. - SHOWER 132

SCALE: 1/2" = 1'-0"A403 A408

14 INT. ELEV. - SHOWER 132

SCALE: 1/2" = 1'-0"A403 A408

15 INT. ELEV. - SHOWER 132

SCALE: 1/2" = 1'-0"A403 A408

16 INT. ELEV. - SHOWER 132

ENLARGED RESTROOM PLAN &

ELEVATION NOTES

1 REFER TO A401 FOR ACCESSORY SCHEDULE, LEGEND AND MOUNTING HEIGHTS.

2 LAYOUTS SHOWN HERE ARE INTENDED TO DEPICT INSTALLATION OF SPECIFIC

ACCESSORIES ONLY. REFER TO SHEETS A401-A408 FOR LAYOUT OF

ACCESSORIES.

3 PROVIDE BLOCKING SUPPORT WITHIN STUD WALL FRAMING PRIOR TO COVERAGE

WITH GYPSUM WALL BOARD.

4 MAINTAIN MINIMUM OF 30 INCHES CLEAR WIDTHS IN FRONT OF ACCESSORIES FOR

WHEELCHAIR ACCESS.

5 REFER TO SPECIFICATION SECTION 10 28 13 FOR ADDITIONAL INFORMATION ON

ACCESSORIES.

6 REFER TO FINISH SCHEDULE ON SHEET A600 FOR COLOR AND MATERIAL.

7 REFER TO A600 FOR FINISH SCHEDULE AND MATERIAL CALLOUTS.

8 REFER TO A403 FOR TYPICAL WALL TILE PATTERNS.

9 REFER TO A602 FOR FLOOR TILE PATTERNS.

10 CS = CLEAR SPACE

11 PROVIDE FLOOR ANCHORED, COLOR THROUGH SOLID PHENOLIC TOILET

COMPARTMENTS AND URINAL SCREENS. REFER TO SPEC. SECTION 10 21 13

TOILET COMPARTMENT. (ROBE HOOK IS CALLED OUT IN SPEC.)

FIRST FLOOR

EL.0' - 0"

CENTRAL

LOBBY

GYP BD, PAINTED

(PT2); REFER TO FINISH

SCHEDULE, A600

LINEAR METAL PAN

CEILING, AC-2; REFER TO

FINISH SCHEDULE

1" REVEAL MOLDING; DRM-

625-100 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

GYP BD, PAINTED

(PT2); REFER TO FINISH

SCHEDULE, A600

3 DIMENSIONAL CURVED SYSTEM; AS

PART OF AI # 1 AND INDICATED FOR

INFORMATION & COORDINATION;

REFER TO A600 & SPECS.

1" REVEAL MOLDING; DRM-625-

100 BY FRY REGLET OR EQUAL.

FINISH TO BE PAINTED TO

MATCH ADJACENT WALL

MINIMUM 3/32" DIAMETER

AIRCRAFT CABLE

EL. 9' - 6"

EL. 25' - 6 1/2"

NOTE: SUSPENDED LIGHTS AND HANGER WIRES FOR LIGHTS NOT SHOWN

IN THIS VIEW FOR CLARITY. REFER TO 2/A120 FOR LIGHT SPACING.

CLERESTORY

LINEAR METAL PAN CEILING, AC-2;

REFER TO FINISH SCHEDULE

EL. 12' - 0"

2'-5" 5'-1"5'-1 1/4" 5'-2" 5'-1" 2'-5" 5'-1 1/4"

2'- 6"

6'- 4"

2'- 6"

6" GYP BD, PAINTED (PT4);

REFER TO FINISH

SCHEDULE, A600

A552

A552

CORNER REVEAL; DRMW-625-

625 BY FRY REGLET OR EQUAL.

1" REVEAL MOLDING; DRM-625-

100 BY FRY REGLET OR EQUAL.

FINISH TO BE PAINTED TO

MATCH ADJACENT WALL

A552

A552

FIRST FLOOR

EL.0' - 0"

CENTRAL

LOBBY

'-1

1/

8"

'-7

/8

'-0

'-1

1/

8"

8'-11 5/8"8'-11 5/8"

GYP BD, PAINTED (PT2);

REFER TO FINISH

SCHEDULE, A600

GYP BD, PAINTED (PT4);

REFER TO FINISH

SCHEDULE, A600

1" REVEAL MOLDING; DRM-

625-100 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

GYP BD, PAINTED (PT2);

REFER TO FINISH

SCHEDULE, A600

3 DIMENSIONAL CURVED SYSTEM;

AS PART OF AI # 1 AND INDICATED

FOR INFORMATION & COORDINATION;

REFER TO A600 & SPECS.

1" REVEAL MOLDING; DRM-625-100

BY FRY REGLET OR EQUAL. FINISH

TO BE PAINTED TO MATCH

ADJACENT WALL

MINIMUM 3/32" DIAMETER

AIRCRAFT CABLE

2'-5" 5'-6 1/8" 5'-7 1/8" 5'-6 1/8" 2'-5" 4'-5 5/8"4'-5 5/8"

2'- 6"

CLERESTORY

EL. 9' - 6"

EL. 21' - 8"

EL. 27' - 3 1/2"

NOTE: SUSPENDED LIGHTS AND HANGER WIRES FOR LIGHTS NOT SHOWN

IN THIS VIEW FOR CLARITY. REFER TO 2/A120 FOR LIGHT SPACING.

2'- 6"

6" 6'-

4"

SUPPLY DIFFUSER; REFER TO

MECHANICAL. PAINT TO

MATCH WALL; REFER TO A600

SUPPLY DIFFUSER; REFER TO

MECHANICAL. PAINT TO

MATCH WALL; REFER TO A600

'-2

EQ EQ

EQ

EQ

A552

A552

EQEQ

EQ

EQ

CORNER REVEAL; DRMW-625-

625 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

A552

A552

CREATE MOCK-UP IN PLACE OF

AREA INDICATED FOR APPROVAL

PRIOR TO PURCHASING PAINT

FOR CLERESTORY

ANCILLARY ITEM #1

FURNITURE, FIXTURES AND

EQUIPMENT (FF&E)

1. INCLUDES, BUT NOT LIMITED TO:

a. ALL INTERIOR FURNITURE INCLUDING TO LOBBY AND

GATE SEATING.

b. ALL ARTWORK

c. SUSPENDED 3-DIMENSIONAL CURVED SYSTEM LOCATED

ABOVE CENTRAL LOBBY 104 IN CLERESTORY 201; REFER

TO SPECIFICATION SECTION 09 54 00 - 3-DIMENSIONAL

CURVED SYSTEM AND KEYNOTE 13.

d. ALL EXTERIOR FURNITURE INCLUDING BUT NOT LIMITED

TO PICNIC TABLES, BENCHES AND PLAY STRUCTURE AND

PLAY AREA SURFACING; REFER TO SPECIFICATION

SECTION 32 18 16.13 - PLAYGROUND PROTECTIVE

SURFACING (ANCILLARY ITEM #1, BID ALTRENATE #3)

e. INSTALLATION AND ADJUSTMENTS

f. SHOULD BID ALTERNATE #3 - PLAY AREA NOT BE

AWARDED, THE PLAY STRUCTURE, PLAY STRUCTURE

SURFACING AND PLAY AREA FURNITURE WILL NOT BE

AWARDED EITHER.

2. REFER TO FURNITURE SCHEDULE AND FURNITURE INSTALLATION

SCHEDULE FOR ADDITIONAL INFORMATION.

3. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND

COORDINATION PURPOSES.

4. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT

AREN’T LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION,

ETC. AND SHALL BE COORDINATED AND INSTALLED AS PART OF

THE BASE BID SCOPE OF WORK.

5. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE

GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF

WORK.

6. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

7. REFER TO BID SCHEDULE FOR PRICING BREAKOUT

REQUIREMENTS.

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A410

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A410

1 INT. ELEV. - CLERESTORY

SCALE: 1/2" = 1'-0"A102 A410

2 INT. ELEV. - CLERESTORY

FIRST FLOOR

EL.0' - 0"

CENTRAL

LOBBY

'-1

/2

4'-5 5/8" 2'-5" 5'-6 1/8" 5'-7 1/8" 5'-6 1/8" 2'-5" 4'-5 5/8"

EL. 9' - 6"

EL. 27' - 3 1/2"

GYP BD, PAINTED (PT2);

REFER TO FINISH

SCHEDULE, A600

GYP BD, PAINTED (PT4);

REFER TO FINISH

SCHEDULE, A600

1" REVEAL MOLDING; DRM-625-

100 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

GYP BD, PAINTED (PT2);

REFER TO FINISH

SCHEDULE, A600

3 DIMENSIONAL CURVED SYSTEM; AS

PART OF AI # 1 AND INDICATED FOR

INFORMATION & COORDINATION;

REFER TO A600 & SPECS.

1" REVEAL MOLDING; DRM-

625-100 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

MINIMUM 3/32" DIAMETER

AIRCRAFT CABLE

Z

CLERESTORY

NOTE: SUSPENDED LIGHTS AND HANGER WIRES FOR LIGHTS NOT SHOWN

IN THIS VIEW FOR CLARITY. REFER TO 2/A120 FOR LIGHT SPACING.

2'- 6"

6'- 4"

6" 4'-

1/

2"

EL. 21' - 8"

'-0

2'- 6"

6"

STOREFRONT 'Z'; REFER

TO A/620 FOR PROFILES

AND DETAILS

A552

A552

A623

A623

CORNER REVEAL; DRMW-625-

625 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

A552

A623

FIRST FLOOR

EL.0' - 0"

CENTRAL

LOBBY

NOTE: SUSPENDED LIGHTS AND HANGER WIRES FOR LIGHTS NOT SHOWN

IN THIS VIEW FOR CLARITY. REFER TO 2/A120 FOR LIGHT SPACING.

EL. 9' - 6"

GYP BD, PAINTED (PT2);

REFER TO FINISH

SCHEDULE, A600

GYP BD, PAINTED (PT4);

REFER TO FINISH

SCHEDULE, A600

1" REVEAL MOLDING; DRM-625-

100 BY FRY REGLET OR EQUAL.

FINISH TO BE PAINTED TO

MATCH ADJACENT WALL

GYP BD, PAINTED (PT2);

REFER TO FINISH

SCHEDULE, A600

3 DIMENSIONAL CURVED

SYSTEM; AS PART OF AI # 1 AND

INDICATED FOR INFORMATION &

COORDINATION; REFER TO A600

& SPECS.

1" REVEAL MOLDING; DRM-

625-100 BY FRY REGLET OR

EQUAL. FINISH TO BE PAINTED

TO MATCH ADJACENT WALL

SUPPLY DIFFUSER; REFER TO

MECHANICAL. PAINT TO

MATCH WALL; REFER TO A600

Y

CLERESTORY

5'-1 1/4" 2'-5" 5'-1" 5'-2" 5'-1" 2'-5" 5'-1 1/4"

2'- 6"

6'- 4"

2'- 6"

6"

SUPPLY DIFFUSER; REFER TO

MECHANICAL. PAINT TO MATCH

WALL; REFER TO A600

MINIMUM 3/32" DIAMETER

AIRCRAFT CABLE

EL. 27' - 3 1/2"

EL. 21' - 8"

STOREFRONT 'Y'; REFER

TO A/620 FOR PROFILES

AND DETAILS

1/

2" 4'-

6"

1'- 2"

1'- 2"

2'- 4"

A552

A552

1" REVEAL JOINT

A623

A623

MINIMUM 3/32" DIAMETER

AIRCRAFT CABLE

EQ EQ

EQ

EQ

EQ EQ

EQ

EQ

CORNER REVEAL; DRMW-625-

625 BY FRY REGLET OR EQUAL.

FINISH TO BE PAINTED TO

MATCH ADJACENT WALL3

A552

A552

A623

ANCILLARY ITEM #1

FURNITURE, FIXTURES AND

EQUIPMENT (FF&E)

1. INCLUDES, BUT NOT LIMITED TO:

a. ALL INTERIOR FURNITURE INCLUDING TO LOBBY AND

GATE SEATING.

b. ALL ARTWORK

c. SUSPENDED 3-DIMENSIONAL CURVED SYSTEM LOCATED

ABOVE CENTRAL LOBBY 104 IN CLERESTORY 201; REFER

TO SPECIFICATION SECTION 09 54 00 - 3-DIMENSIONAL

CURVED SYSTEM AND KEYNOTE 13.

d. ALL EXTERIOR FURNITURE INCLUDING BUT NOT LIMITED

TO PICNIC TABLES, BENCHES AND PLAY STRUCTURE AND

PLAY AREA SURFACING; REFER TO SPECIFICATION

SECTION 32 18 16.13 - PLAYGROUND PROTECTIVE

SURFACING (ANCILLARY ITEM #1, BID ALTRENATE #3)

e. INSTALLATION AND ADJUSTMENTS

f. SHOULD BID ALTERNATE #3 - PLAY AREA NOT BE

AWARDED, THE PLAY STRUCTURE, PLAY STRUCTURE

SURFACING AND PLAY AREA FURNITURE WILL NOT BE

AWARDED EITHER.

2. REFER TO FURNITURE SCHEDULE AND FURNITURE INSTALLATION

SCHEDULE FOR ADDITIONAL INFORMATION.

3. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND

COORDINATION PURPOSES.

4. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT

AREN’T LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION,

ETC. AND SHALL BE COORDINATED AND INSTALLED AS PART OF

THE BASE BID SCOPE OF WORK.

5. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE

GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF

WORK.

6. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

7. REFER TO BID SCHEDULE FOR PRICING BREAKOUT

REQUIREMENTS.

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A411

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A411

1 INT. ELEV. - CLERESTORY

SCALE: 1/2" = 1'-0"A102 A411

2 INT. ELEV. - CLERESTORY

CENTRAL

LOBBY

S

EL. 0' - 0"

EL. 10' - 0"

EL. 9' - 6"

REFER TO A551 FOR

COLUMN ELEVATIONS

AND DETAILS

REFER TO A620 FOR

STOREFRONT ELEVATIONS

& GLAZING TYPES

CENTRAL

LOBBY

8'- 0"

EL. 0' - 0"

EL. 10' - 0"

EL. 9' - 6"

11'-7"

CASED OPENING

TO SECURITY

SCREENING 147

TRB1

PT3

TRB1

PT3

INTERIOR SIGNAGE; SIGN TYPE

CC1a, REFER TO A641 & A642

REFER TO A551 FOR

COLUMN ELEVATIONS

AND DETAILS

8'- 0"

CENTRAL

LOBBY

EL. 0' - 0"

EL. 9' - 6"

EL. 10' - 0"

9'-2"

CASED OPENING

TO CORRIDOR TO

ARRIVAL WAITING

TRB1

PT3

TRB1

PT3

INTERIOR SIGNAGE; SIGN TYPE

CC1a, REFER TO A641 & A642

FIDS; REFER TO AVS01 &

AVS02 (AI # 4). MOUNTING

HEIGHT 5'-1" TO CENTER

REFER TO A551 FOR COLUMN

ELEVATIONS AND DETAILS

PSC

CASEWORK; REFER

TO A702 - A705

C C

CENTRAL

LOBBY

5'-10" 5'-8" 5'-10" 2'-6" 5'-10" 5'-8"

4'- 6"

NOTE: REFER TO ELEVATION 1/A416 FOR BACK WALL ELEVATION

INTERIOR SIGNAGE; SIGN TYPE

CC1, REFER TO A641 & A642

EL. 0' - 0"

EL. 9' - 6"

EL. 10' - 0"

REFER TO A620 FOR STOREFRONT

ELEVATIONS & GLAZING TYPES

REFER TO A620 FOR STOREFRONT

ELEVATIONS & GLAZING TYPES

REFER TO BHE01 (AI # 2) FOR BAGGAGE

HANDLING EQUIPMENT REQUIREMENTS

REFER TO BHE01 (AI # 2) FOR BAGGAGE

HANDLING EQUIPMENT REQUIREMENTS

REFER TO A551 FOR

COLUMN ELEVATIONS

AND DETAILS

ST1

PL1

PL1

A702

ST1

AIR MOBILITY COMMAND SHIELD

VINYL DECAL PROVIDED AND

INSTALLED BY CONTRACTOR

3'-2"

VINYL DECAL PROVIDED AND

INSTALLED BY CONTRACTOR

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A412

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A412

1 INT. ELEV. - CENTRAL LOBBY

SCALE: 1/2" = 1'-0"A102 A412

2 INT. ELEV. - CENTRAL LOBBY

SCALE: 1/2" = 1'-0"A103 A412

3 INT. ELEV. - CENTRAL LOBBY

CASEWORK NOTES

1 COLOR MATCH CAULK WITH EITHER PLASTIC LAMINATE OR WALL FINISH, WHICHEVER IS

DARKER. CONFIRM WITH CONTRACTING OFFICER.

2 CAULK ALL EDGES OF PLASTIC LAMINATE AND COUNTERTOP MATERIALS WHERE

MATERIALS ABUT OTHER SURFACES AND FINISHES, AT ALL INTERIOR AND EXTERIOR

SEAMS AND CORNERS COMPLETE. PROVIDE BACKER ROD FOR ALL GAPS GREATER THAN

1/4".

3 GROMMET LOCATIONS INDICATED ON ENLARGED PLANS ARE APPROXIMATE. LOCATE A

MINIMUM OF 2" FROM EDGE OF MATERIALS. VERIFY FINAL GROMMET LOCATIONS WITH

CONTRACTING OFFICER.

4 REFER TO A600 FOR ROOM FINISH SCHEDULE AND COLOR SCHEDULE

5 CONTRACTOR TO FIELD VERIFY ALL WALL DIMENSIONS AT CASEWORK LOCATIONS PRIOR

TO FABRICATION

6 WALL CABINETS ARE 12" DEEP, UNLESS NOTED OTHERWISE

7 BASE AND STORAGE CABINETS ARE 24" DEEP, UNLESS NOTED OTHER WISE.

8 CABINETS TO RECEIVE BASE TO MATCH ADJACENT WALL BASE, UNLESS NOTED OTHER

WISE.

9 ALL FILLERSTRIPS TO MATCH ADJACENT CABINETS. PROVIDE EQUAL FILLERSTRIP AT BOTH

SIDES, UNLESS NOTED OTHER WISE.

10 PROVIDE FINISHED END PANELS WHERE EXPOSED AT BASE AND WALL CABINETS.

11 REFER TO SPECIFICATION SECTIONS 06 41 16 . 00 10- LAMINATE CLAD ARCHITECTURAL

CASEWORK, 06 61 16 - SOLID POLYMER (SOLID SURFACING) FRABRICATIONS AND 06 12 36

00 - COUNTERTOPS.

12 REFER TO A401-A422 & A701-A705 FOR CASEWORK PLANS, ELEVATIONS, SECTIONS,

DETAILS AND FINISH TAGS.

13 EQUPMENT SHOWN FOR COORDINATION ONLY - REFER TO FF + E PACKAGE.

14 COORDINATE ELECTRICAL AND DATA OUTLET LOCATIONS PRIOR TO ROUGHING IN

ELECTRICAL AND/OR PREPARING CASEWORK SHOP DRAWINGS.

15 PROVIDE WALL BASE AND FLOOR FINISHES PER FINISH SCHEDULE UNLESS NOTED OTHER

WISE WHERE WALLS/FLOORS ARE EXPOSED AT UNDERSIDES OF ALL COUNTERS.

16 REFER TO SPECIFICATION SECTION 06 41 00.00 10 LAMINATE CLAD ARCHITECTURAL

CASEWORK FOR ADDITIONAL FINISH INFORMATION.

17 EACH 1/2 HEIGHT DOOR IN CASEWORK TO HAVE 1 PAIR 4" STEEL DOUBLE ACTING SPRING

HINGES. FINISH TO BE SATIN CHROME.

INTERIOR ELEVATION NOTES

1 REFER TO A600 FOR FINISH SCHEDULE AND COLOR SCHEDULE.

2 REFER TO A411 FOR GENERAL CASEWORK NOTES.

3 REFER TO A610 FOR DOOR SCHEDULE.

4 REFER TO A620 FOR STORE FRONT ELEVATIONS.

5 REFER TO A000 FOR FULL DESCRIPTION OF ANCILLARY ITEMS (AI) AND BID ALTERNATES

SCALE: 1/2" = 1'-0"A102 A412

4 INT. ELEV. - CENTRAL LOBBY

8'- 0"

3'- 6"

4'- 6"

CENTRAL

LOBBY

CASED OPENING

TO ENHANCED

VENDING 173

CASED

OPENING TO

CARTS 102

8'- 0"

6'-0"10'-0"

8'- 0"

1'- 6"

TRB1

PT3

TRB1

PT3

INTERIOR SIGNAGE;

SIGN TYPE BB7, REFER

TO A641 & A642

INTERIOR SIGNAGE; SIGN TYPE

CC1, REFER TO A641 & A642

INTERIOR SIGNAGE;

SIGN TYPE CC1, REFER

TO A641 & A642

EL. 0' - 0"

EL. 10' - 0"

EL. 9' - 6"

PCS

REFER TO A551 FOR

COLUMN ELEVATIONS

AND DETAILS

CASEWORK; REFER

TO A702-A705

CENTRAL

LOBBY

101B

A551

TRB1

PT3

TRB1

PT3

INTERIOR SIGNAGE;

SIGN TYPE BB7,

REFER TO A641 & A642

INTERIOR SIGNAGE; SIGN TYPE

BB7, REFER TO A641 & A642

EL. 0' - 0"

EL. 10' - 0"

EL. 9' - 6"

REFER TO A551 FOR

COLUMN ELEVATIONS

AND DETAILS

C

1058'- 0"

8'- 0"

CENTRAL

LOBBY

6'-0" 10'-0"

CASED OPENING

TO ADMIN LOBBY

CASED

OPENING TO

CARTS 103

8'- 0"

TRB1

PT3

TRB1

PT3

INTERIOR SIGNAGE; SIGN TYPE

BB7, REFER TO A641 & A642

INTERIOR SIGNAGE;

SIGN TYPE CC1a, REFER TO A641 & A642

TV; REFER TO FF&E

(AI # 1). MOUNTING

HEIGHT 5'-1" TO CENTER

EL. 0' - 0"

EL. 9' - 6"

EL. 10' - 0"

REFER TO A551 FOR

COLUMN ELEVATIONS

AND DETAILS

REFER TO A620 FOR STOREFRONT

ELEVATIONS & GLAZING TYPES

CENTRAL

LOBBY

11'-6"

CASED OPENING

TO CORRIDOR

INTERIOR SIGNAGE; SIGN TYPE

CC1a, REFER TO A641 & A642

FIDS; REFER TO AVS01 &

AVS02 (AI # 4). MOUNTING

HEIGHT 5'-1" TO CENTER

EL. 0' - 0"

EL. 10' - 0"

EL. 9' - 6"

FLIGHT CHECK-IN

COUNTER

REFER TO A551 FOR COLUMN

ELEVATIONS AND DETAILS

CASEWORK; REFER

TO A702-A705

REFER TO A620 FOR

STOREFRONT ELEVATIONS

& GLAZING TYPES

6" 9'-

6"10 '-0

PT3

TRB1

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A413

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A413

1 INT. ELEV. - CENTRAL LOBBY

SCALE: 1/2" = 1'-0"A102 A413

2 INT. ELEV. - CENTRAL LOBBY

SCALE: 1/2" = 1'-0"A102 A413

3 INT. ELEV. - CENTRAL LOBBY

CASEWORK NOTES

1 COLOR MATCH CAULK WITH EITHER PLASTIC LAMINATE OR WALL FINISH, WHICHEVER IS

DARKER. CONFIRM WITH CONTRACTING OFFICER.

2 CAULK ALL EDGES OF PLASTIC LAMINATE AND COUNTERTOP MATERIALS WHERE

MATERIALS ABUT OTHER SURFACES AND FINISHES, AT ALL INTERIOR AND EXTERIOR

SEAMS AND CORNERS COMPLETE. PROVIDE BACKER ROD FOR ALL GAPS GREATER THAN

1/4".

3 GROMMET LOCATIONS INDICATED ON ENLARGED PLANS ARE APPROXIMATE. LOCATE A

MINIMUM OF 2" FROM EDGE OF MATERIALS. VERIFY FINAL GROMMET LOCATIONS WITH

CONTRACTING OFFICER.

4 REFER TO A600 FOR ROOM FINISH SCHEDULE AND COLOR SCHEDULE

5 CONTRACTOR TO FIELD VERIFY ALL WALL DIMENSIONS AT CASEWORK LOCATIONS PRIOR

TO FABRICATION

6 WALL CABINETS ARE 12" DEEP, UNLESS NOTED OTHERWISE

7 BASE AND STORAGE CABINETS ARE 24" DEEP, UNLESS NOTED OTHER WISE.

8 CABINETS TO RECEIVE BASE TO MATCH ADJACENT WALL BASE, UNLESS NOTED OTHER

WISE.

9 ALL FILLERSTRIPS TO MATCH ADJACENT CABINETS. PROVIDE EQUAL FILLERSTRIP AT BOTH

SIDES, UNLESS NOTED OTHER WISE.

10 PROVIDE FINISHED END PANELS WHERE EXPOSED AT BASE AND WALL CABINETS.

11 REFER TO SPECIFICATION SECTIONS 06 41 16 . 00 10- LAMINATE CLAD ARCHITECTURAL

CASEWORK, 06 61 16 - SOLID POLYMER (SOLID SURFACING) FRABRICATIONS AND 06 12 36

00 - COUNTERTOPS.

12 REFER TO A401-A422 & A701-A705 FOR CASEWORK PLANS, ELEVATIONS, SECTIONS,

DETAILS AND FINISH TAGS.

13 EQUPMENT SHOWN FOR COORDINATION ONLY - REFER TO FF + E PACKAGE.

14 COORDINATE ELECTRICAL AND DATA OUTLET LOCATIONS PRIOR TO ROUGHING IN

ELECTRICAL AND/OR PREPARING CASEWORK SHOP DRAWINGS.

15 PROVIDE WALL BASE AND FLOOR FINISHES PER FINISH SCHEDULE UNLESS NOTED OTHER

WISE WHERE WALLS/FLOORS ARE EXPOSED AT UNDERSIDES OF ALL COUNTERS.

16 REFER TO SPECIFICATION SECTION 06 41 00.00 10 LAMINATE CLAD ARCHITECTURAL

CASEWORK FOR ADDITIONAL FINISH INFORMATION.

17 EACH 1/2 HEIGHT DOOR IN CASEWORK TO HAVE 1 PAIR 4" STEEL DOUBLE ACTING SPRING

HINGES. FINISH TO BE SATIN CHROME.

INTERIOR ELEVATION NOTES

1 REFER TO A600 FOR FINISH SCHEDULE AND COLOR SCHEDULE.

2 REFER TO A411 FOR GENERAL CASEWORK NOTES.

3 REFER TO A610 FOR DOOR SCHEDULE.

4 REFER TO A620 FOR STORE FRONT ELEVATIONS.

5 REFER TO A000 FOR FULL DESCRIPTION OF ANCILLARY ITEMS (AI) AND BID ALTERNATES

SCALE: 1/2" = 1'-0"A102 A413

4 INT. ELEV. - CENTRAL LOBBY

127B 128

2'-6" 2'-6" 2'-6" 2'-0"

9'-6"

3'- 0"

1'- 6"

2'- 6"

7'- 0"

3'- 0"

FE-1

PT2

RB1

EL. 0' - 0"

EL. 10' - 0"

PL2

PL2

SS1

PT2 2

A701

VINYL TILE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

BREAK

ROOM

A701

A701

REFRIGERATOR,

UFUI

MICROWAVE,

UFUI

A

2'-6" 2'-6" 2'-6" 2'-6"

10'-0"

3'- 0"

1'- 6"

2'- 6"

7'- 0"

3'- 0"

FE-1

PASSENGER

LOUNGE

PL2

PL2

PL2 RB1

PT2

A701

SS1

VINYL TILE, REFER TO

FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

A701

EL. 0' - 0"

EL. 10' - 0"

ALUM STOREFRONT;

REFER TO A600 & A620

ALUM STOREFRONT;

REFER TO A620

MICROWAVE,

UFUI

2'-6" 2'-6" 2'-6" 2'-6"

10'-0"

3'- 0"

1'- 6"

2'- 6"

7'- 0"

3'- 0"

A701

PL2

PL2

SS1PT2

PT2

PT2

EL. 0' - 0"

EL. 10' - 0"

3'- 0"

1'- 6"

2'- 6"

FAMILY

LOUNGE

QZ1

PL3

PL3

PT7

RB2

FRAMED

OPENING

PT7

RB2

7'- 0"

2'-6" 2'-6" 2'-6"

7'-6"

UNDER-

COUNTER

FRIG, UFUI

A701

VINYL TILE, REFER TO

FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

167A

A701

A701

EL. 0' - 0"

EL. 10' - 0"

TV; REFER TO FF&E (AI # 1).

MOUNTING HEIGHT 5'-1" TO

CENTERMICROWAVE,

UFUI

2'-6" 2'-6" 2'-0" 2'-0"

9'-0"

3'- 0"

1'- 6"

2'- 6"

2'- 0"

7'- 0"

PL2

PT2

RB1

SS1

PL2

COPY AREA

EL. 0' - 0"

A701

EL. 9' - 0"

SPEC. CAT

LOUNGE

3'- 0"

1'- 6"

2'- 6"

MICROWAVE,

UFUI

PL4

PL4

QZ2

WB1

WCR1

AWC2

WB1

AWC2

UNDER-

COUNTER

FRIG, UFUI

PT1 PT1

PM1 PM1

PT1 PT1

2'- 0"

8'- 0"

EL. 0' - 0"

EL. 10' - 0"

CARPET, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

PICTURE MOLDING,

REFER TO FINISH

SCHEDULE

CHAIR RAIL, REFER

TO FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

1'- 0"

6'- 0"

3'- 0"

PT1

PT4

PT4

2'- 6"

4"

A701

COUNTER &

BACKSPLASH, QZ2

APRON, PL4

WB1

WCR1

AWC2

PT1

PM1

PT1

A701

'-0

7'- 0"

2'-0" 2'-0" 2'-0" 6'-0"

A701

ENHANCED

VENDING

AREA

2'- 6"

1'- 6"

3'- 0"

3'- 0"

7'- 0"

2'-6" 2'-6" 2'-6"

7'-6"

PL2

PL2

SS1FRAMED

OPENING

PT2

RB1

PT2

EL. 0' - 0"

EL. 10' - 0"

VINYL TILE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

A701

A701

MICROWAVE,

UFUI

2'-6" 2'-6" 2'-6" 2'-6" 1'-6"

11'-6"

3'- 0"

4"

ST1

PL2

A701

A701

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A414

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A414

5 INT. ELEV. - BREAK ROOM 127

CASEWORK NOTES

1 COLOR MATCH CAULK WITH EITHER PLASTIC LAMINATE OR WALL FINISH, WHICHEVER IS

DARKER. CONFIRM WITH CONTRACTING OFFICER.

2 CAULK ALL EDGES OF PLASTIC LAMINATE AND COUNTERTOP MATERIALS WHERE

MATERIALS ABUT OTHER SURFACES AND FINISHES, AT ALL INTERIOR AND EXTERIOR

SEAMS AND CORNERS COMPLETE. PROVIDE BACKER ROD FOR ALL GAPS GREATER THAN

1/4".

3 GROMMET LOCATIONS INDICATED ON ENLARGED PLANS ARE APPROXIMATE. LOCATE A

MINIMUM OF 2" FROM EDGE OF MATERIALS. VERIFY FINAL GROMMET LOCATIONS WITH

CONTRACTING OFFICER.

4 REFER TO A600 FOR ROOM FINISH SCHEDULE AND COLOR SCHEDULE

5 CONTRACTOR TO FIELD VERIFY ALL WALL DIMENSIONS AT CASEWORK LOCATIONS PRIOR

TO FABRICATION

6 WALL CABINETS ARE 12" DEEP, UNLESS NOTED OTHERWISE

7 BASE AND STORAGE CABINETS ARE 24" DEEP, UNLESS NOTED OTHER WISE.

8 CABINETS TO RECEIVE BASE TO MATCH ADJACENT WALL BASE, UNLESS NOTED OTHER

WISE.

9 ALL FILLERSTRIPS TO MATCH ADJACENT CABINETS. PROVIDE EQUAL FILLERSTRIP AT BOTH

SIDES, UNLESS NOTED OTHER WISE.

10 PROVIDE FINISHED END PANELS WHERE EXPOSED AT BASE AND WALL CABINETS.

11 REFER TO SPECIFICATION SECTIONS 06 41 16 . 00 10- LAMINATE CLAD ARCHITECTURAL

CASEWORK, 06 61 16 - SOLID POLYMER (SOLID SURFACING) FRABRICATIONS AND 06 12 36

00 - COUNTERTOPS.

12 REFER TO A401-A422 & A701-A705 FOR CASEWORK PLANS, ELEVATIONS, SECTIONS,

DETAILS AND FINISH TAGS.

13 EQUPMENT SHOWN FOR COORDINATION ONLY - REFER TO FF + E PACKAGE.

14 COORDINATE ELECTRICAL AND DATA OUTLET LOCATIONS PRIOR TO ROUGHING IN

ELECTRICAL AND/OR PREPARING CASEWORK SHOP DRAWINGS.

15 PROVIDE WALL BASE AND FLOOR FINISHES PER FINISH SCHEDULE UNLESS NOTED OTHER

WISE WHERE WALLS/FLOORS ARE EXPOSED AT UNDERSIDES OF ALL COUNTERS.

16 REFER TO SPECIFICATION SECTION 06 41 00.00 10 LAMINATE CLAD ARCHITECTURAL

CASEWORK FOR ADDITIONAL FINISH INFORMATION.

17 EACH 1/2 HEIGHT DOOR IN CASEWORK TO HAVE 1 PAIR 4" STEEL DOUBLE ACTING SPRING

HINGES. FINISH TO BE SATIN CHROME.

INTERIOR ELEVATION NOTES

1 REFER TO A600 FOR FINISH SCHEDULE AND COLOR SCHEDULE.

2 REFER TO A411 FOR GENERAL CASEWORK NOTES.

3 REFER TO A610 FOR DOOR SCHEDULE.

4 REFER TO A620 FOR STORE FRONT ELEVATIONS.

5 REFER TO A000 FOR FULL DESCRIPTION OF ANCILLARY ITEMS (AI) AND BID ALTERNATES

SCALE: 1/2" = 1'-0"A102 A414

3 INT. ELEV. - PASSENGER LOUNGE 108

SCALE: 1/2" = 1'-0"A102 A414

4 INT. ELEV. - PASSENGER LOUNGE 108

SCALE: 1/2" = 1'-0"A103 A414

7 INT. ELEV. - FAMILY LOUNGE 167

NEW CONSTRUCTION

KEYNOTES

2 VENDING MACHINES PROVIDED AND INSTALLED BY OTHERS. REFER

TO ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL

REQUIREMENTS.

SCALE: 1/2" = 1'-0"A102 A414

6 INT. ELEV. - COPY AREA 116

SCALE: 1/2" = 1'-0"A102 A414

1 INT. ELEV. - SPEC. CAT LOUNGE 144

SCALE: 1/2" = 1'-0"A103 A414

2 INT. ELEV. - VENDING AREA 173

SCALE: 1/2" = 1'-0"A422 A414

8 INT. ELEV. - CASEWORK

A312

149A

FE-1

DEPARTURE

GATE 1

PT2, REFER TO

COLOR SCHEDULE

RB1

PT2

A572

A572

A572

A572

CARPET, REFER TO

FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

EL. 0' - 0"

EL. 9' - 8"

BAGGAGE

CLAIM

PT3 PT3

4'-0"

6'- 0"

TRB1

OPEN

TERRAZZO, REFER

TO FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

EL. 0' - 0"

EL. 10' - 0"

DRAFT CURTAIN,

COORDINATE INSTALLATION

W/ BHE MANUFACTURER

VERIFY OPENING SIZE

W/ BHE MANUFACTURER

REFER TO AA24/I201

FOR ARTWORK

LOCATIONS

A572

A572

A572

A572

BAGGAGE

CLAIM

PT3

4'-0"

6'- 0"

TRB1

OPEN

TERRAZZO, REFER

TO FINISH SCHEDULE

BASE, REFER TO

FINISH SCHEDULE

ACT, REFER TO

FINISH SCHEDULE

GYP BD, REFER TO

FINISH SCHEDULE

EL. 0' - 0"

EL. 10' - 0"

DRAFT CURTAIN

COORDINATE INSTALLATION

W/ BHE MANUFACTURER

VERIFY OPENING SIZE W/

BHE MANUFACTURER

A572

A572

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A415

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A415

1 INT. ELEV. - DEPARTURE GATE-1 149

SCALE: 1/2" = 1'-0"A103 A415

2 INT. ELEV. - BAGGAGE CLAIM 156

SCALE: 1/2" = 1'-0"A103 A415

3 INT. ELEV. - BAGGAGE CLAIM 156

NEW CONSTRUCTION

KEYNOTES

3 BAGGAGE HANDLING EQUIPMENT (BHE) TO BE PROVIDED AND

INSTALLED UNDER SEPERATE CONTRACT, SHALL BE COORDINATED

BY CONTRACTOR. REFER TO MEP DRAWINGS FOR REQUIREMENTS

WHICH ARE PART OF THE BASE BID AND IN THE GENERAL

CONTRACTORS SCOPE OF WORK.

12 FOLDING PANEL PARTITION SHALL BE PROVIDED AND INSTALLED BY

CONTRACTOR - REFER TO STRUCTURAL, ELECTRICAL AND

SPECIFICATION SECTION 10 22 39 FOLDING PANEL PARTITION.

INTERIOR ELEVATION NOTES

1 REFER TO A600 FOR FINISH SCHEDULE AND COLOR SCHEDULE.

2 REFER TO A411 FOR GENERAL CASEWORK NOTES.

3 REFER TO A610 FOR DOOR SCHEDULE.

4 REFER TO A620 FOR STORE FRONT ELEVATIONS.

5 REFER TO A000 FOR FULL DESCRIPTION OF ANCILLARY ITEMS (AI) AND BID ALTERNATES

FLIGHT

CHECK-IN

COUNTER

REFER TO BHE01 (AI # 2) FOR

BAGGAGE HANDLING EQUIPMENT

REQUIREMENTS

5'-5"

4'- 2"

AIR MOBILITY COMMAND

SHIELD VINYL DECAL PROVIDED

AND INSTALLED BY GENERAL

CONTRACTOR

437TH AERIAL PORT SQUADRON SHIELD

VIYNL DECAL PROVIDED AND INSTALLED

BY GENERAL CONTRACTOR

WALL OPENING FOR

BAGGAGE; COORDINATE SIZE

WITH BHE MANUFACTURER

CHECK-IN DESK CHECK-IN DESK

4'- 4"

1'- 2"

1'- 0"

8'- 4"

1'- 0"

7'- 4"

C C

PT11

PT10

PT9

PT3

PT3

4"

DRAFT CURTAIN,

COORDINATE INSTALLATION

W/ BHE MANUFACTURER

CHECK-IN DESK

EL. 0' - 0"

EL. 8' - 4"

REFER TO A620 FOR STOREFRONT

ELEVATIONS & GLAZING TYPES

REFER TO A620 FOR STOREFRONT

ELEVATIONS & GLAZING TYPES

NOTE: CONTRACTOR TO COORDINATE WITH CONTRACTING OFFICER TO RECEIVE MILITARY SHIELDS PDF'S INDICATED TO BE PRINTED AS DECALS. DECALS SHALL BE DIGITALLY PRINTED 720 x 720 DPI (MINIMUM) ON 6 MIL. LOW TACK VINYL.

CONTRACTOR TO FIELD VERIFY LOCATIONS PRIOR TO INSTALLATION.

3'-2" 8'-11"VINYL DECAL LETTERS; COLOR TO BE

SILVER; PROVIDED AND INSTALLED BY

GENERAL CONTRACTOR

1'- 4"

SS3; REFER TO COLOR

SCHEDULE; A600

PHONES; PROVIDED AND

INSTALLED BY OTHERS

2'- 6"

4"

8'-0"

8'- 0"

9'- 6"

A701

9 9 9

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A416

IN

TE

RI

OR

E

LE

VA

TI

ON

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A422 A416

1 INT. ELEV. - FLIGHT CHECK-IN COUNTER 133

INTERIOR ELEVATION NOTES

1 REFER TO A600 FOR FINISH SCHEDULE AND COLOR SCHEDULE.

2 REFER TO A411 FOR GENERAL CASEWORK NOTES.

3 REFER TO A610 FOR DOOR SCHEDULE.

4 REFER TO A620 FOR STORE FRONT ELEVATIONS.

5 REFER TO A000 FOR FULL DESCRIPTION OF ANCILLARY ITEMS (AI) AND BID ALTERNATES

SCALE: 1/2" = 1'-0"A103 A416

2 INT. ELEV. - PHONE BANK

A416

5'- 8"

5'-

2'-

6" 5'-

5'- 8"

5'-

6'-9"

2'- 6"

4" 2'-

6"

5'- 4"

FLIGHT

CHECK-IN

COUNTER

3'-9" 4'-3"

5'- 4"

2'- 6"

4" 2'-

6"

TA

KE

A W

AY

C

ON

VE

YO

R;

RE

FE

R

TO

B

HE

(A

I #

) F

OR

BA

GG

AG

E

HA

ND

LI

NG

EQ

UI

PM

EN

T

RE

QU

IR

EM

EN

TS

CH

EC

K-

IN

C

OU

NT

ER

CH

EC

K-

IN

C

OU

NT

ER

CH

EC

K-

IN

C

OU

NT

ER

CHECK-IN

COUNTER

6'-9"

SCALE/FEEDER CONVEYOR; REFER TO

BHE01 (AI # 2) FOR BAGGAGE

HANDLING EQUIPMENT REQUIREMENTS

A702

A702

M1

M1

5'- 5"

3'-0"

OPENING HEIGHT, 7'-0"

5'-1 0 1

/2"

2'-6

A703

A703

OPENING HEIGHT, 4'-2"

A702

A702

A702

2'-6"

5'-6"

'-4

SOFFIT ABOVE

GROMMET

SOFFIT ABOVE

SOFFIT ABOVE

5.

SOFFIT ABOVE

A702

A703

COUNTER-TOP

M1

M1

F8

M10

M9

C2

M9

KNEE SPACE

DURESS ALARM; REFER TO ANCILLARY

ITEM #3, INTRUSION DETECTION

SYSTEM; IDS01 & IDS02, TYP.

GROMMET; REFER

TO NOTE 3

GROMMET; REFER

TO NOTE 3

GROMMET; REFER

TO NOTE 3

GROMMET; REFER

TO NOTE 3

11'-5 7/8"

C

C

SCALE/FEEDER CONVEYOR; REFER TO

BHE01 (AI # 2) FOR BAGGAGE

HANDLING EQUIPMENT REQUIREMENTS

SCALE/FEEDER CONVEYOR; REFER TO

BHE01 (AI # 2) FOR BAGGAGE

HANDLING EQUIPMENT REQUIREMENTS

SCALE/FEEDER CONVEYOR;

REFER TO BHE01 (AI # 2) FOR

BAGGAGE HANDLING

EQUIPMENT REQUIREMENTS

KNEE SPACE

DURESS ALARM; REFER TO ANCILLARY

ITEM #3, INTRUSION DETECTION

SYSTEM; IDS01 & IDS02, TYP.

KNEE SPACE

DURESS ALARM; REFER TO ANCILLARY

ITEM #3, INTRUSION DETECTION

SYSTEM; IDS01 & IDS02, TYP.

KNEE SPACE

DURESS ALARM; REFER TO ANCILLARY

ITEM #3, INTRUSION DETECTION

SYSTEM; IDS01 & IDS02, TYP.

F

PSC

CAR

RENTAL

CENTRAL

LOBBY

A705

A705

9'-1 1/4"+/-

6'-5

1'-6

5'-1 3/4

6" 8"

1'-10"

2'-6"

2'- 6"

TRANSACTION

COUNTER

TRANSACTION

COUNTER

BASE CABINET

BASE CABINET

BASE CABINET

BASE CABINET

OPEN SHELVING

OPEN SHELVING

A704

A704

A704

4'- 0"

3'- 0"

3'-0"

1'-10" 8" 6"

2'-

1/ 2"

4'-7 1/4"+/- 4'-6" 5'-0" 1'-7 3/4"

13' -0

3/4

2'-6"

A704

A704

COUNTER TOP

5°

A704M1

M1

M1 M1

M1

M1 M1

M4

M4

C2

M1

A702

A702

A414

A551

KNEE SPACE

GROMMET; REFER

TO NOTE 3

GROMMET; REFER

TO NOTE 3

GROMMET; REFER

TO NOTE 3

KNEE SPACE

COUNTERTOPGROMMET; REFER

TO NOTE 3

M1

A704

A704

GROMMET; REFER

TO NOTE 3

3'-0"

1'-6"

2'-6"

7'- 0"

7'-0"

M1

60" CS

GROMMET; REFER

TO NOTE 3

A414

DURESS ALARM; REFER TO

ANCILLARY ITEM #3, INTRUSION

DETECTION SYSTEM; IDS01 &

IDS02, TYP.

DURESS ALARM; REFER TO

ANCILLARY ITEM #3, INTRUSION

DETECTION SYSTEM; IDS01 &

IDS02, TYP.

DURESS ALARM; REFER TO

ANCILLARY ITEM #3, INTRUSION

DETECTION SYSTEM; IDS01 &

IDS02, TYP.

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A422

EN

LA

RG

ED

P

LA

NS

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/2" = 1'-0"A102 A422

1 ENLARGED PLAN - FLIGHT CHECK-IN COUNTER

SCALE: 1/2" = 1'-0"A102 A422

2 ENLARGED PLAN - PSC/CAR RENTAL

CASEWORK NOTES

1 COLOR MATCH CAULK WITH EITHER PLASTIC LAMINATE OR WALL FINISH, WHICHEVER IS

DARKER. CONFIRM WITH CONTRACTING OFFICER.

2 CAULK ALL EDGES OF PLASTIC LAMINATE AND COUNTERTOP MATERIALS WHERE

MATERIALS ABUT OTHER SURFACES AND FINISHES, AT ALL INTERIOR AND EXTERIOR

SEAMS AND CORNERS COMPLETE. PROVIDE BACKER ROD FOR ALL GAPS GREATER THAN

1/4".

3 GROMMET LOCATIONS INDICATED ON ENLARGED PLANS ARE APPROXIMATE. LOCATE A

MINIMUM OF 2" FROM EDGE OF MATERIALS. VERIFY FINAL GROMMET LOCATIONS WITH

CONTRACTING OFFICER.

4 REFER TO A600 FOR ROOM FINISH SCHEDULE AND COLOR SCHEDULE

5 CONTRACTOR TO FIELD VERIFY ALL WALL DIMENSIONS AT CASEWORK LOCATIONS PRIOR

TO FABRICATION

6 WALL CABINETS ARE 12" DEEP, UNLESS NOTED OTHERWISE

7 BASE AND STORAGE CABINETS ARE 24" DEEP, UNLESS NOTED OTHER WISE.

8 CABINETS TO RECEIVE BASE TO MATCH ADJACENT WALL BASE, UNLESS NOTED OTHER

WISE.

9 ALL FILLERSTRIPS TO MATCH ADJACENT CABINETS. PROVIDE EQUAL FILLERSTRIP AT BOTH

SIDES, UNLESS NOTED OTHER WISE.

10 PROVIDE FINISHED END PANELS WHERE EXPOSED AT BASE AND WALL CABINETS.

11 REFER TO SPECIFICATION SECTIONS 06 41 16 . 00 10- LAMINATE CLAD ARCHITECTURAL

CASEWORK, 06 61 16 - SOLID POLYMER (SOLID SURFACING) FRABRICATIONS AND 06 12 36

00 - COUNTERTOPS.

12 REFER TO A401-A422 & A701-A705 FOR CASEWORK PLANS, ELEVATIONS, SECTIONS,

DETAILS AND FINISH TAGS.

13 EQUPMENT SHOWN FOR COORDINATION ONLY - REFER TO FF + E PACKAGE.

14 COORDINATE ELECTRICAL AND DATA OUTLET LOCATIONS PRIOR TO ROUGHING IN

ELECTRICAL AND/OR PREPARING CASEWORK SHOP DRAWINGS.

15 PROVIDE WALL BASE AND FLOOR FINISHES PER FINISH SCHEDULE UNLESS NOTED OTHER

WISE WHERE WALLS/FLOORS ARE EXPOSED AT UNDERSIDES OF ALL COUNTERS.

16 REFER TO SPECIFICATION SECTION 06 41 00.00 10 LAMINATE CLAD ARCHITECTURAL

CASEWORK FOR ADDITIONAL FINISH INFORMATION.

17 EACH 1/2 HEIGHT DOOR IN CASEWORK TO HAVE 1 PAIR 4" STEEL DOUBLE ACTING SPRING

HINGES. FINISH TO BE SATIN CHROME.

NEW CONSTRUCTION

KEYNOTES

3 BAGGAGE HANDLING EQUIPMENT (BHE) TO BE PROVIDED AND

INSTALLED UNDER SEPERATE CONTRACT, SHALL BE COORDINATED

BY CONTRACTOR. REFER TO MEP DRAWINGS FOR REQUIREMENTS

WHICH ARE PART OF THE BASE BID AND IN THE GENERAL

CONTRACTORS SCOPE OF WORK.

5/8" GYP. BD. OR

BACKER BD; REFER TO

FINISH SCHEDULE AND

SPEC SECTION 09 29 00

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M4 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

5/8" GYP. BD

SOUND BATT

WALL TYPES

5/8" GYP. BD. OR

BACKER BD; REFER TO

FINISH SCHEDULE AND

SPEC SECTION 09 29 00

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M5 NON-RATED METAL STUD WALL

5/8" GYP. BD

5/8" BACKER BD;

REFER TO SPEC

SECTION 09 29 00

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

P1 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

BRACE W/ GYP BD

OR STUD TRACK @

48" AFF & 112" AFF

SOUND BATT

5/8" GYP. BD.

6" METAL STUDS @

16" o.c. UNO; 25 GA.

F5 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

R-13 BATT INSULATION

5/8" GYP. BD.

7/8" METAL FURRING

@ 16" o.c. UNO; 20 GA.

F1 NON-RATED METAL STUD WALL

EXTEND TO 6" ABOVE CEILING

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

5/8" GYP. BD. MOISTURE

RESISTANT OR BACKER BD;

REFER TO FINISH SCHEDULE

AND SPEC SECTION 09 29 00

F4 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

R-13 BATT INSULATION

5/8" GYP. BD.

3-5/8" METAL STUDS @

16" o.c. UNO; 25 GA.

F6 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

4" SHOTCRETE - REFER TO STRUCTURAL

5/8" BACKER BD;

REFER TO SPEC

SECTION 09 29 00

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

P2 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

SOUND BATT

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

5/8" GYP. BD.

F2 NON-RATED METAL STUD WALL

EXTEND TO 6" ABOVE CEILING

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

5/8" GYP. BD. OR BACKER BD; REFER TO

FINISH SCHEDULE AND SPEC SECTION 09 29 00

C2 NON-RATED METAL STUD WALL

EXTEND TO 6" ABOVE CEILING

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS @

16" o.c. UNO; 25 GA.

5/8" GYP. BD. BOTH SIDES

C4 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS @

16" o.c. UNO; 25 GA.

R-13 BATT INSULATION

5/8" GYP. BD. BOTH SIDES

C9 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS @ 16" o.c. UNO

4" SHOTCRETE - REFER TO STRUCTURAL

5/8" GYP. BD. OR BACKER BD; REFER TO FINISH

SCHEDULE AND SPEC SECTION 09 29 00

C5 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

6" METAL STUDS @ 16" o.c. UNO; 25 GA.

3-5/8" METAL STUDS @ 16" o.c. UNO

SOUND BATT

5/8" GYP. BD.

C8 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS @ 16" o.c. UNO; 25 GA.

4" SHOTCRETE - REFER TO STRUCTURAL

5/8" GYP. BD. BOTH SIDES

C3 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS @

16" o.c. UNO

SOUND BATT

5/8" GYP. BD.

F3 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

SOUND BATT

5/8" GYP. BD.

C6 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

SOUND BATT

3-5/8" METAL STUDS @ 16" o.c. UNO; 25 GA.

NEW / EXISTING CMU(FIELD VERIFY SIZE)

5/8" GYP. BD.

6" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M7 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

5/8" GYP. BD

EXTEND TO 6" ABOVE CEILING

EXTEND TO DECK (APPROX. 12'-3" AFF)

R-13 BATT INSULATION

5/8" GYP. BD.

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M6 NON-RATED METAL STUD WALL

5/8" GYP. BD

FU

LL

W

ID

TH

N

OT

S

HO

W

N

PFM C

GENERAL NOTES:

- STUD SPACING / GAGE?

- REFER TO FINISH SCHEDULE

FOR CEILING HEIGHTS

5/8" GYP. BD.

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M1 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

SOUND BATT

5/8" GYP. BD.

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M2 NON-RATED METAL STUD WALL

EXTEND TO 6" ABOVE CEILING

5/8" GYP. BD.

3-5/8" METAL STUDS

@ 16" o.c. UNO; 20 GA.

M3 NON-RATED METAL STUD WALL

5/8" GYP. BD

3'-6" HIGH FROM FINISH FLOOR

5/8" GYP. BD.

3-5/8" METAL STUDS @ 16" o.c. UNO; 25 GA.

F7 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

6" SHOTCRETE - REFER TO STRUCTURAL

R-13 BATT INSULATION

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

C1 NON-RATED CMU WALL

REFER TO STRUCTURAL FOR HEIGHTS & REINFORCING

NEW 7-5/8" CMU

C7 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

4" SHOTCRETE - REFER TO STRUCTURAL

FU

LL

W

ID

TH

N

OT

S

HO

W

N

FU

LL

W

ID

TH

N

OT

S

HO

W N

FU

LL

W

ID

TH

N

OT

S

HO

W

N

FU

LL

W

ID

TH

N

OT

S

HO

W N

FU

LL

W

ID

TH

N

OT

S

HO

W

N

FU

LL

W

ID

TH

N

OT

S

HO

W N

SOUND BATT

5/8" GYP. BD.

3-5/8" METAL STUDS

@ 16" o.c. UNO -

STAGGARED; 25 GA.

M8 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

5/8" GYP. BD

SOUND BATT

7 1/4"

5/8" GYP. BD. BOTH SIDES

C10 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS @ 16" o.c. UNO; 25 GA.

4" SHOTCRETE - REFER TO STRUCTURAL

R-13 BATT INSULATION

4 1/4"

4 1/4"

4 7/8"

4 7/8"

4 7/8"

4 7/8"

7 1/4" 10 1/4"

8 1/4"

6 5/8"

4 1/4"

4 1/4"

4 1/4"

1 1/2" 10 1/2" 7 5/8"

1'-8 1/8"1'-4 1/8"

1'-4 1/8"

1'-4 1/8"

1'-6 1/2"

1'-8 1/8"

AIR SPACE

BRACE W/ GYP BD OR

STUD TRACK @ 48"

AFF & 112" AFF

5/8" IMPACT RATED GYP. BD.

ON ROOM SIDE OF 137, 157

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M9 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

5/8" GYP. BD.

SOUND BATT

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

M10 NON-RATED METAL STUD WALL

5/8" GYP. BD.

EXTEND TO 6" ABOVE CEILING

4 7/8"

4 7/8"

5/8" IMPACT

RATED GYP. BD.

F8 NON-RATED METAL STUD WALL

EXTEND TO 6" ABOVE CEILING

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

5/8" IMPACT

RATED GYP. BD.

F9 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

SOUND BATT

FU

LL

W

ID

TH

N

OT

S

HO

W

N

FU

LL

W

ID

TH

N

OT

S

HO

W N

4 1/4"

4 1/4"

5/8" IMPACT RATED

GYP. BD. MOISTURE

RESISTANT

F10 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

NEW / EXISTING CMU

(FIELD VERIFY SIZE)

3-5/8" METAL STUDS

@ 16" o.c. UNO; 25 GA.

R-13 BATT INSULATION

FU

LL

W

ID

TH

N

OT

S

HO

W

N

4 1/4"

5/8" IMPACT RATED GYP. BD.

MOISTURE RESISTANT

3-5/8" METAL STUDS @ 16" o.c. UNO; 25 GA.

F11 NON-RATED METAL STUD WALL

EXTEND TO DECK (APPROX. 12'-3" AFF)

6" SHOTCRETE - REFER TO STRUCTURAL

R-13 BATT INSULATION

NEW / EXISTING CMU

(FIELD VERIFY SIZE)FU

LL

W

ID

TH

N

OT

S

HO

W N

10 1/4"

5/8" IMPACT RATED GYP. BD.

ON ROOM SIDE OF 137, 157

2'-1 1/4"

1'-5"

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A501

W

AL

L

TY

PE

S T

YP

IC

AL

W

AL

L

DE

TA

IL

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

CUT BRICK

AIR SPACE

1/2" EXT. GRADE SHEATHING

1-1/2" MTL STUD

STEEL TUBE COLUMN - REFER

TO STRUCTURAL DWGS.

2'-2"

2'- 2"

CUT BRICK

BRICK VENEER

PROVIDE 3/4" CONDUIT & PULLSTRING FROM

ELECTRICAL PANEL TO LIGHT LOCATIONS WITH

COLUMNS. ALL WIRING IS TO BE CONCEALED,

COORDINATE WITH ELECTRICAL

BRICK SILL BELOW

BRICK VENEER

AIR SPACE

1/2" EXT. GRADE SHEATHING

1-1/2" MTL STUD

STEEL TUBE COLUMN - REFER

TO STRUCTURAL DWGS.

2'-0"

2'- 0"

PROVIDE 3/4" CONDUIT & PULLSTRING FROM

ELECTRICAL PANEL TO LIGHT LOCATIONS WITH

COLUMNS. ALL WIRING IS TO BE CONCEALED,

COORDINATE WITH ELECTRICAL

CENTER FIXTURE ON COLUMN FACE;

REFER TO ELECTRICAL FOR LOCATIONS

FIRST FLOOR

EL.0' - 0"

EXPANSION JOINT

CONCRETE SLAB, SEE

STRUCTURAL DWGS.

CONCRETE FOOTING,

REFER TO STRUCTURAL

DWGS.

AIR SPACE

TUBE STEEL COLUMN,

SEE STRUCTURAL DWGS.

CONCRETE BASE, REFER

TO STRUCTURAL DWGS.

BRICK VENEER,

MASONRY ANCHORS

@ 16" O.C. EACH WAY

BRICK ROWLOCK

2'-2"

2'-0"

6 1/2"

7 1/2"

1-1/2" MTL STUD (18 GA.)

1/2" SHEATHING

SELF-ADHERED

BITUTHENE

SEALANT &

BACKER-ROD

MORTAR NET

THRU WALL FLASHING, LAP

BLDG FELT OVER FLASHING

WEEPS @ 24" O.C.

GROUT SOLID

T.O. WATERTABLE

A502

A502

STEEL ANGLE, REFER

TO STRUCTURAL

EL. 2' - 8"

EL. 8' - 0"

T.O. BRICK

1/2" 1/2"

1"

NQ

CAST STONE CAP

PAINT, REFER TO

FINISH SCHEDULE

EL. 7' - 4"

T.O. LIGHT FIXTURE

(REFER TO ELECTRICAL

FOR LOCATIONS)

PROVIDE 3/4" CONDUIT & PULLSTRING

FROM ELECTRICAL PANEL TO LIGHT

LOCATIONS WITH COLUMNS. ALL

WIRING IS TO BE CONCEALED,

COORDINATE WITH ELECTRICAL

BRICK ROWLOCK

LIGHT FIXTURE; REFER

TO ELECTRICAL

2'-4"

2'- 4"

3" 2"

2'-4"

2'- 4"

3"

1'-1 7/8" 3/8" 1'-1 7/8"

2'-4"

5/

8"

3/ 4"

5/

8"

9 5/8" 8 3/4" 9 5/8"

CAST STONE CAP (TYPE 1) CAST STONE CAP (TYPE 2)

3/8" MORTAR

JOINT

FIRST FLOOR

EL.0' - 0"

A502

8'- 0"

2" 4"

5'- 4"

2'- 8"

2'-0"

2'-2"

4'- 4"

2" 2'-

8"

7'- 2"

BRICK VENEER

MASONRY

BRICK CAP

DARK BRONZE WROUGHT

IRON FENCE INSERT

INTERMEDIATE FENCE

SUPPORTS; DARK BRONZE

VERIFY IN FIELD WITH FENCE LAYOUT

(4'-6") - (5'-0") SPACING

CAST STONE CAP

(TYPE 1)

A502

SimN9.9

WALL BRACKET

WALL BRACKET

POST BRACKET; TO

MATCH FENCE INSERT

STEEL PLATE; DARK BRONZE

POST BRACKET; TO

MATCH FENCE INSERT

FIRST FLOOR

EL.0' - 0"

EXPANSION JOINT

CONCRETE SLAB, REFER

TO STRUCTURAL DWGS.

CONCRETE FOOTING,

REFER TO STRUCTURAL

DWGS.

AIR SPACE

DARK BRONZE WROUGHT

IRON FENCE INSERT

8" CMU, REFER TO

STRUCTURAL DWGS.

BRICK VENEER,

MASONRY ANCHORS

@ 16" O.C. EACH WAY

BRICK CAP

MORTAR NET

THRU WALL FLASHING,

LAP FELT OVER FLASHING

7'- 2"

2'- 8"

2" 4'-

4"

6" 3'-

4" 6"

FILL GROUT SOLID

EL. 2' - 8"

T. O. WALL

NA.4

4'- 6"

CMU

1/2 UNIT, SOLID

NC.8NC.5

4" 6'-

0"

3'-0"

DARK BRONZE

WROUGHT IRON GATE

CAST STONE

CAP (TYPE 2)

CAST STONE

CAP (TYPE 1)

HINGE; REFER TO

HARDWARE SPEC

SECTION 08 71 00

LATCH; REFER TO

HARDWARE SPEC

SECTION 08 71 00

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A502

M

AS

ON

RY

C

OL

UM

N

PL

AN

S/

SE

C

TI

ON

S

AN

D

DE

TA

IL

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1" = 1'-0"A102 A502

1 COLUMN DETAIL - LOW

SCALE: 1" = 1'-0"A502 A502

2 COLUMN DETAIL - HIGH

SCALE: 1" = 1'-0"A102 A502

3 WALL SECTION @ BRICK COLUMN

SCALE: 1" = 1'-0"A502

4 PRECAST COLUMN CAP

SCALE: 1" = 1'-0"A102 A502

5 ELEVATION DETAIL @ FENCE (BID ALTERNATE # 3)

SCALE: 1" = 1'-0"A103 A502

6 WALL SECTION @ PLAY AREA (BID ALTERNATE # 3)

SCALE: 1" = 1'-0"A103 A502

7 ENLARGED ELEVATION - PLAY AREA GATE (BID ALTERNATE # 3)

M

EXISTING CMU WALL

SHOTCRETE; REFER TO

STRUCTURAL DWGS.

METAL STUDS

GYPSUM

WALLBOARD

METAL STUDS

METAL STUDS

GYPSUM

WALLBOARD

BATT

INSULATION

METAL STUDS

BATT

INSULATION

EXISTING

CMU WALL

EXISTING BRICK

VENEER

SOUND BATTS

C9

F4

F5

N

EXISTING CMU

SHOTCRETE - REFER TO

STRUCTURAL DWGS.

METAL STUDS

GYPSUM WALLBOARD

METAL STUDS

SETTING BED

APPLIED TO CMU

TILE FINISH; REFER TO

FINISH SCHEDULE

BATT

INSULATION

METAL STUDS

BATT INSULATION

NEW CMU WALL; REFER TO

STRUCTURAL FOR REINFORCING

REQUIREMENTS

NEW BRICK VENEER

BACKER BOARD

C8

F4

M

METAL STUDS

BATT INSULATION

NEW CMU WALL; REFER TO

STRUCTURAL ROR

REINFORCING REQUIREMENTS

NEW BRICK VENEER

EXISTING CMU WALL

EXISTING BRICK VENEER

GYPSUM WALLBOARD

METAL STUDS

BATT INSULATION

GYPSUM WALLBOARD

F4

F4

CORNER TRIM

LED LEAD

WIRE ("WHIP")

CLIP ATTACHMENT

PVC STANDOFF, TYP.

SEALTITE

CONNECTOR

LED ILLUMINATION

(WHITE)

.090" BRUSHED

ALUMINUM FACE

CLEAR LEXAN

BACK

POWER SUPPLY; VERIFY

REQUIREMENTS WITH

SIGN MANUFACTURER

1 1/2" 3 1/2"

5"

.090" BRUSHED

ALUMINUM FACE

3-1/2" (.063) BRUSHED

ALUMINUM RETURN

CLEAR LEXAN

BACK

SEALTITE

CONNECTOR

LED ILLUMINATION

(WHITE)

CLIP ATTACHMENT

SIDE VIEW FRONT VIEW

3-1/2" (.063) BRUSHED

ALUMINUM RETURN

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A503

EX

TE

RI

OR

W

AL

L

PL

AN

D

ET

AI

LS

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 3" = 1'-0"A102 A503

1 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A102 A503

2 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A102 A503

3 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A503

4 REVERSE LIT CHANNEL LETTERS

L

EXISTING CMU WALL

SHOTCRETE; REFER TO

STRUCTURAL

METAL STUD

GYPSUM WALLBOARD

TILE FINISH; REFER TO

FINISH AND COLOR

SCHEDULE

SETTING BED

APPLIED TO CMU

MTL STUD

GYPSUM

WALLBOARD

SHOTCRETE; REFER TO

STRUCTURAL

C10

C8

C8

EXISTING CMU WALL

METAL STUDS

GYPSUM WALLBOARD

METAL STUDS

GYPSUM WALLBOARD

SHOTCRETE; REFER TO

STRUCTURAL

METAL STUDS

GYPSUM WALLBOARD

C2

F6

M4

L

METAL FURRING

STRIPS

GYPSUM

WALLBOARD

TILE FINISH; REFER TO FINISH

AND COLOR SCHEDULE

SETTING BED

APPLIED TO CMU

GYPSUM WALLBOARD

METAL STUDS

SHOTCRETE; REFER TO

STRUCTURAL

METAL STUDS

GYPSUM

WALLBOARD

EXISTING CMU WALL

C8

M4

E

TILE FINISH; REFER TO FINISH

AND COLOR SCHEDULE

SETTING BED

EXISTING CMU WALL

METAL STUDS

GYPSUM

WALLBOARD

GYPSUM WALLBOARD

METAL STUDS SHOTCRETE; REFER

TO STRUCTURAL

DOOR FRAME

BACKER BOARD

C10

M5

METAL STUDS; REFER

TO WALL TYPES

GYPSUM WALL BOARD;

REFER TO WALL TYPES

NEW CMU WALL; REFER TO

STRUCTURAL FOR REINFORCING

REQUIREMENTS

4"

F9

SOUND BATTS

GYPSUM WALL BOARD;

REFER TO WALL TYPES

CASED OPENING; VERIFY SIZE

WITH BHE MANUFACTURER

DRAFT CURTAINS; COORDINATE

INSTALLATION WITH BHE

MANUFACTURER

CORNER TRIM

CORNER TRIM

EXISTING CMU WALL SHOTCRETE; REFER TO

STRUCTURAL

METAL STUD

GYPSUM WALLBOARDTILE FINISH; REFER TO FINISH

AND COLOR SCHEDULE

SETTING BED

APPLIED TO CMU

CORNER BEAD'J' BEAD

GYPSUM WALL BOARD;

ADHERE TO SHOTCRETE AND

CMU, ATTACH TO STUD

G

METAL STUD

BACKER BOARD

EXISTING CMU WALL TILE FINISH; REFER TO FINISH

AND COLOR SCHEDULE

SETTING BED

METAL STUD

SETTING BED

TILE FINISH; REFER TO

FINISH AND COLOR

SCHEDULE

BACKER BOARD

WALL TILE PATTERN 2, 8'-0"

HIGH; REFER TO A403

METAL STUD

BACKER BOARD

TILE; REFER TO FINISH AND

COLOR SCHEDULE

SETTING BED

METAL STUD

TILE; REFER TO FINISH AND

COLOR SCHEDULE

BACKER BOARD

'J' BEAD

BACKER BOARD

TILE; REFER TO FINISH AND

COLOR SCHEDULE, ON

SETTING BED

SETTING BED

DOOR FRAME

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A504

IN

TE

RI

OR

W

AL

L

PL

AN

D

ET

AI

LS

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 3" = 1'-0"A102 A504

1 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A102 A504

2 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A102 A504

3 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A102 A504

4 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A102 A504

5 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A401 A504

6 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A402 A504

7 WALL PLAN DETAIL

SCALE: 3" = 1'-0"A403 A504

8 WALL PLAN DETAIL

BREAK METAL WRAPPED FASCIA;

PRE-FINISHED TO MATCH STANDING

SEAM METAL ROOF PANELS

STANDING SEAM METAL

ROOF PANELS; REFER TO EXTERIOR

MATERIAL & COLOR SCHEDULE

ZEE PURLIN

META…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .