Attachment__2_-_Drawings_dated_30_October_2013_-_Part_12.pdf
PDF 6 MB Posted
- Attached to
- Add/Repair Passenger Terminal, Bldg. 164
- Solicitation number
- FA4418-15-R-0009
About this file
Attachment 2 - Drawings dated 30 October 2013 - Part 12 for Solicitation FA4418-16-R-0002 Add/Repair Passenger Terminal Bldg 164.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REF.
GARAGE
COMM.
WOMEN
MEN
READING ROOM
OIC OFFICE
SUPT. OFFICE
STORAGE
CONFERENCE
TRAINING
STO.
COPY AREA
ADMIN
LOUNGE LOBBY
PASSENGER
LOUNGE
BREAK ROOM
WOMENS
131 OPS NCOIC
OFFICE
VESTIBULE
CARTS
ENHANCED
VENDING AREA
VESTIBULE
CAR RENTAL
PSC
FAMILY
LOUNGE
RESTROOM
CRIB ROOM
PLAY ROOM
ELEC.
ARRIVAL
WAITING
SPRINKLER
RISER ROOM
BAGGAGE
CLAIM
MECHANICAL
MEN
WOMEN
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
CUSTOMS
154SECURITY
SCREENING
SECURE GATE
CORRIDOR
DEPARTURE
GATE 2
MEN
WOMEN
DEPARTURE/ARRIVAL
GATE 3
BAGGAGE
BREAKDOWN
SPEC. CAT
LOUNGE
UNISEX
SHOWER/
CHANGING
ROOM
BUSINESS
CENTER
COMM.
BAGGAGE
SCREENING
FUNDS
SUPR.
FLIGHT
CHECK#IN
COUNTER
DISPATCH
CENTRAL
LOBBY
DEPARTURE
GATE 1
LOST & FOUND
COVERED
CANOPY AREA
BAGGAGE
BUILD UP
LOCATION OF
FIRE
DEPARTMENT
CONNECTION
1 2
A
B
C
H
3 4 5 5.2 7 7.1 7.9 8 9 9.3 9.7 10 11
CANOPY CONSTRUCTED OF
NON*COMBUSTIBLE
MATERIAL NOT REQUIRED
TO BE SPRINKLERED PER
NFPA 13, 2010 SECTION
8.15.7.
CANOPY
CONSTRUCTED OF
NON*COMBUSTIBLE
MATERIAL NOT
REQUIRED TO BE
SPRINKLERED PER
NFPA 13, 2010 SECTION
8.15.7.
SPRINKLER ROLL*UP
DOORS PER NFPA 13
(TYPICAL)
COMM.
GAME ROOM
TV ROOM
MECH./ELEC.
OPEN OFFICE
COMM.
8" F
FIRE HYDRANT
#135
FIRE HYDRANT
#136
8" F
FIRE HYDRANT
#139
FIRE HYDRANT
#140
8" FIRE
SPRINKLER
LINE
CONTINUED
ON CIVIL
PLANS
MEN
WOMEN
CARTS
N
M
L.8
L
K
J
G
F
E
MENS
ALCOVE
SHOWER
SHOWER
CORRIDOR
D
CONTROLLER
ADMIN LOBBY
CORRIDOR
CORRIDOR
JANITOR
CLOSET
1 OUTLINE OF
CLERESTORY
FP102
FP102
"ADD" WORK
RELATED TO NEW
BUILDING
ADDITIONS
"ADD" WORK
RELATED TO NEW
BUILDING
ADDITIONS
"ADD" WORK
RELATED TO NEW
BUILDING
ADDITIONS
OUTLINE
OF SOFFIT
(TYP.), SEE
ARCH. RCP
LOCATION
OF ATTIC
ACCESS
SPRINKLER ROLL*UP
DOORS PER NFPA 13
(TYPICAL)
LIMITS OF BID ALTERNATE #3
FIRE PROTECTION LEGEND
AREAS OF HC*3 HAZARD CLASSIFICATION
AREAS OF ORDINARY GROUP 1 HAZARD
COVERAGE
AREAS OF ORDINARY GROUP 2 HAZARD
COVERAGE
AREAS OF HC*2 HAZARD CLASSIFICATION
AREAS OF HC*1 HAZARD CLASSIFICATION
DELUGE SYSTEM, AREAS
OF HC*2 HAZARD
CLASSIFICATION
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
E
G
No.
L
TU
D
S
IC
A H
ISM
R E
T E
O
K
E G. W
E S
AA
17759
RE
G E
ER
IN
E N
L
RCAH
ORP
SEF
OL
N
S IO
IN
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N5' 10' 20'
3/32"
FP101
FI
RS
T
FL
O O R
FI
RE
P
RO
TE
C
TI
O N P
LA
N
W
DB
W
DB
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 3/32" = 1'*0"FP101
1 FIRST FLOOR FIRE PROTECTION FLOOR PLAN
NOTE:
FIRE SPRINKLER LINES AND FIRE HYDRANT LOCATIONS
ARE APPROXIMATE AND MUST BE VERIFIED WITH CIVIL
DRAWINGS. SEE CIVIL FIRE FLOW TEST FOR ADDITIONAL
INFORMATION.
SPRINKLER KEYED NOTES
CLERESTORY TO BE SERVED BY DELUGE SYSTEM WITH PENDANT TYPE
HEADS LOCATED IN CEILING ABOVE CLOUD SYSTEM AND SIDEWALL TYPE
SPRINKLER HEADS LOCATED BELOW CLOUD SYSTEM AS SHOWN IN
SECTIONS ON FP102. SIDEWALL TYPE SPRINKLER HEADS SHALL BE
EXTENDED COVERAGE (K8.0 WITH MAXIMUM SPACING OF 16' x 16'), AND
PENDANT TYPE SPRINKLER HEADS SHALL BE STANDARD COVERAGE.
COORDINATE DELUGE INSTALLATION WITH FIRE ALARM CONTRACTOR TO
PROVIDE INTEGRATED SYSTEM.
EXTERIOR BAGGAGE BREAKDOWN AREA SHALL BE SERVED BY DRY
TYPE SPRINKLER HEADS OFF OF THE WET PIPE SYSTEM CONCEALED IN
THE ATTIC SPACE ABOVE.
CEILINGS IN INDICATED ROOMS ARE OPEN TO STRUCTURE ABOVE IN
SOME PLACES, AND THEREFORE REQUIRE SPRINKLER COVERAGE
ABOVE AND BELOW CEILINGS. SEE ARCHITECTURAL REFLECTED CEILING
PLAN FOR ADDITIONAL INFORMATION.
LOCATION OF WET SPRINKLER RISER AND DELUGE VALVE RISER, SEE
SCHEMATIC PIPING DIAGRAM FOR ADDITIONAL INFORMATION.
DRY TYPE HEADS OFF THE WET SYSTEM SHALL BE PROVIDED IN THE
GARAGE FOR FREEZE PROTECTION.
(THIS SHEET ONLY)
1 2
A
B
C
H
3 4 5 5.2 7 7.1 7.9 8 9 9.3 9.7 10 11
N
M
L.8
L
K
J
G
F
E
D
LOCATION
OF
CLEREST
ORY
FP102
FP102
CENTRAL
LOBBY
FP102
ATTIC
ATTIC
FP102
CENTRAL
LOBBY
ATTICATTIC
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
E
G
No.
L
TU
D
S
IC
A H
ISM
R E
T E
O
K
E G. W
E S
AA
17759
RE
G E
ER
IN
E N
L
RCAH
ORP
SEF
OL
N
S IO
IN
0'
= 1'*0"
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
5' 10' 20'
3/32"
FP102
AT
TI
C F
IR
E
PR
O
TE
C
TI
O N P
LA
N
W
DB
W
DB
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 3/32" = 1'*0"FP102
1 ATTIC FIRE PROTECTION PLAN
SPRINKLER KEYED NOTES
LOCATION OF CLERESTORY, SEE FP101 FOR COVERAGE
REQUIREMENTS.
(THIS SHEET ONLY)
SCALE: 1/8" = 1'*0"FP102
2 CLERESTORY SECTION A
SCALE: 1/8" = 1'*0"FP102
3 CLERESTORY SECTION B 155
NORTH
SIDE
SOUTH
SIDE
PROVIDE ALL MATERIALS AND LABOR NECESSARY FOR A COMPLETE
PLUMBING SYSTEM.
DO NOT SCALE DRAWINGS. OBTAIN ROUGHIN DIMENSIONS FROM
ARCHITECTURAL DRAWINGS OR FROM MANUFACTURERS PRINTED
INSTRUCTIONS AND RECOMMENDATIONS ONLY. CONTRACTOR SHALL
COORDINATE EXACT LOCATIONS OF ALL EQUIPMENT, CONNECTIONS
AND LINES WITH THE OWNER PRIOR TO INSTALLATION OF ANY PIPING.
FIELD VERIFY LOCATIONS AND INVERT ELEVATIONS BEFORE
BEGINNING WORK.
COORDINATE PLUMBING SYSTEMS WITH ALL TRADES TO AVOID
CONFLICTS PRIOR TO INSTALLATION OF PLUMBING COMPONENTS.
OBTAIN ALL PERMITS AND INSPECTIONS FROM AUTHORITY HAVING
JURISDICTION. THIS INCLUDES ALL FEES THAT MAY BE REQUIRED.
PROVIDE OWNER WITH CERTIFICATES OF FINAL INSPECTION FROM
AUTHORITY HAVING JURISDICTION.
WHENEVER THE WORD "PROVIDE" IS USED, IT SHALL MEAN FURNISH
AND INSTALL COMPLETE AND READY FOR USE.
UNLESS OTHERWISE SHOWN OR NOTED, ALL PIPING SHALL BE RUN
CONCEALED IN WALLS, CHASES AND/OR ABOVE CEILINGS.
ALL SUSPENDED PIPING SHALL BE SUPPORTED FROM BUILDING
STRUCTURAL MEMBERS. IN NO CASE SHALL PIPING BE SUSPENDED
FROM FLOOR OR ROOF DECK.
WHERE PIPES PENETRATE FIRE RATED ASSEMBLIES, SEAL OPENING
AROUND PIPES WITH U.L. LISTED FIRE STOPPING MATERIAL TO
MAINTAIN THE FIRE RATING OF THE ASSEMBLY.
PROVIDE DRAIN VALVES AT ALL LOW POINTS WHERE POSSIBLE IN
HOT & COLD PIPING SYSTEMS.
PROVIDE TRAP PRIMER VALVES ON ALL FLOOR DRAINS.
PROVIDE ALL VENT PENETRATIONS WHERE INDICATED ON FLOOR
PLANS. COLLECT ALL VENTS ABOVE CEILING WHERE SHOWN.
PROVIDE INSULATION FOR WASTE PIPING COLLECTING CONDENSATE
DRAIN.
INSTALL ALL SANITARY WASTE AND VENT PIPING IN ACCORDANCE
WITH APPLICABLE CODES AND STANDARDS. PROVIDE HANGERS AND
SUPPORTS WITHIN 12" OF EACH HORIZONTAL ELBOW.
REFER TO A000 FOR GENERAL ANCILLARY ITEM AND BID ALTERNATE
NOTES.
PLUMBING NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
A. EQUIPMENT, APPLIANCES AND SUPPORTS (INLCUDING ROOF CURBS & ROOF RAILS) EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. WHERE SEISMIC RESTRAINT IS REQUIRED, THE MORE DEMANDING FORCE OF WIND AND SEISMIC MUST BE USED. SEE SEISMIC INFORMATION CONTAINED IN THE STRUCTURAL DRAWINGS FOR SITE SPECIFIC INFORMATION ON SEISMIC DESIGN CATEGORY. SEE EQUIPMENT SCHEDULES AND DETAILS FOR SPECIFIC COMPONENT IMPORTANCE FACTOR DESIGNATIONS.
B. USE APPLICABLE TABLE BELOW TO DETERMINE SEISMIC RESTRAINT REQUIREMENTS FOR EACH MECHANICAL COMPONENT.
C. FOR ALL COMPONENTS REQUIRING SEISMIC RESTRAINT, THE COMPONENT SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED
BY A REGISTERED DESIGN PROFESSIONAL. SUBMITTAL MUST INCLUDE STAMPED AND SIGNED DRAWINGS AND CALCULATIONS.
D. WHERE SEISMIC RESTRAINT IS REQUIRED, HOUSEKEEPING PADS NEEDED FOR THE INSTALLATION OF EQUIPMENT UNDER THIS
CONTRACT MUST BE DESIGNED BY THE SEISMIC ENGINEER. DO NOT POUR ANY HOUSEKEEPING PADS PRIOR TO THE THE
RECEIPT OF THE SEISMIC SUBMITTAL.
E. SEISMIC RESTRAINTS FOR PIPING MUST BE SHOWN ON LAYOUT DRAWINGS SHOWING SPECIFIC RESTRAINT LOCATIONS ALONG
WITH ACCOMPANYING DETAILS AND CALCULATIONS.
• ALL PLUMBING COMPONENTS
EXCEPT AS LISTED UNDER Ip = 1.5
PLUMBING COMPONENT IMPORTANCE FACTOR
(Ip) DESIGNATION
Ip = 1.0
PER IBC*2006 /ASCE 7*05
SEISMIC AND WIND REQUIREMENTS FOR PLUMBING SYSTEMS
COMPONENT IMPORTANCE FACTOR (Ip)
RESTRAIN IF ANY PIPE
ON TRAPEZE > 1"
RESTRAIN IF TOTAL WEIGHT OF
PIPES ON TRAPEZE > 10 LBS/FT
4 RESTRAIN ALL
RESTRAIN IF ANY PIPE
ON TRAPEZE > 3"
RESTRAIN IF TOTAL WEIGHT OF
PIPES ON TRAPEZE > 10 LBS/FT
RESTRAIN ALL
SUSPENDED PIPE ON TRAPEZE
SUSPENDED NON DUCTILE PIPING
(CAST IRON, PLASTIC, CERAMIC)
NOTES:
1. EQUIPMENT 20 LBS. OR LESS IS EXEMPT IF FLEXIBLE CONNECTIONS ARE PROVIDED BETWEEN THE COMPONENT AND
ASSOCIATED PIPING AND CONDUIT.
2. RESTRAINTS ARE NOT REQUIRED IF THE COMPONENT WEIGHS 400 LBS. OR LESS, IS MOUNTED AT 4 FT. OR LESS ABOVE A FLOOR, AND HAS FLEXIBLE CONNECTIONS BETWEEN THE COMPONENT AND ASSOCIATED PIPING AND CONDUIT.
3. FLEXIBLE CONNECTIONS REQUIRED FOR PIPE CONNECTIONS ONLY.
4. RESTRAINT IS NOT REQUIRED IF THE PIPING IS SUPPORTED BY HANGERS AND EACH HANGER IN THE PIPING RUN IS 12 IN. OR
LESS IN LENGTH FROM THE TOP OF THE PIPE TO THE SUPPORTING STRUCTURE. WHERE PIPES ARE SUPPORTED ON A TRAPEZE, THE TRAPEZE SHALL BE SUPPORTED BY HANGERS HAVING A LENGTH OF 12 IN. OR LESS. WHERE ROD HANGERS ARE USED, THEY SHALL BE EQUIPPED WITH SWIVELS, EYE NUTS OR OTHER DEVICES TO PREVENT BENDING IN THE ROD.
5. COMPONENT CERTIFICATION MUST BE SUPPLIED BY THE EQUIPMENT MANUFACTURER AT TIME OF SUBMITTAL FOR REVIEW
BY ENGINEER OF RECORD.
NOTES
1.51.0
5REQUIRED5NOT REQUIREDCOMPONENT CERTIFICATION
(SEE NOTE 6)
4>1"4>3"
SUSPENDED DUCTILE PIPING
(STEEL, ALUMINUM, COPPER, ETC.)
3RESTRAIN ALL3RESTRAIN ALLSUSPENDED EQUIPMENT
*RESTRAIN ALL1RESTRAIN ALLCOMPONENT SUPPORTS
*RESTRAIN ALL1, 2RESTRAIN ALLWALL MOUNTED
*RESTRAIN ALL1, 2RESTRAIN ALLFLOOR MOUNTED
*RESTRAIN ALL1RESTRAIN ALLROOF MOUNTED
SEISMIC RESTRAINT
REQUIREMENTNOTESSEISMIC RESTRAINT
REQUIREMENTCOMPONENT IDENTIFICATION
SEISMIC DESIGN CATEGORIES D,E,F
Ip = 1.5
• NATURAL GAS PIPING
IE
FG
TYP
U/G
(E)
FFE
B/F
FC
AFG
FD
GCO
VTR
FCO
WCO
BV
FD
GCO
FCO
FINISH GRADE
INVERT ELEVATION
UNDER GROUND
TYPICAL
FINISH FLOOR ELEVATION
FLOW CONTROL
ABOVE FINISH GRADE
BELOW FLOOR
EXISTING
BALL VALVE
FLOOR DRAIN
VENT THRU ROOF
GRADE CLEANOUT
WALL CLEAN OUT
FLOOR CLEANOUT
PLUMBING SYMBOLS
ABBREVIATION
C
H
V
W
SYMBOL
SOIL AND WASTE PIPING
VENT PIPING
DESCRIPTION
DOMESTIC COLD WATER PIPING
DOMESTIC HOT WATER PIPING
TMV TMV THERMOSTATIC MIXING VALVE
AFF ABOVE FINISH FLOOR
PIPE UP
PIPE DN
PIPE REDUCER
PIPE STRAIGHT TEE
PIPE TEE DN
DN DOWN
DOMESTIC HOT WATER RETURN PIPINGHWR
G GAS PIPING
HAMMER ARRESTOR SCHEDULE
PDI UNITITEM
HA A 1*11
FIXTURE UNIT MANUFACTURER
JOSAM 75000 OR
EQUIVALENT ZURN, SMITH
JOSAM 75000 OR
EQUIVALENT ZURN, SMITHHA B 12*32
JOSAM 75000 OR
EQUIVALENT ZURN, SMITH
HA C 33*60
HA D 61*113
JOSAM 75000 OR
EQUIVALENT ZURN, SMITH
JOSAM 75000 OR
EQUIVALENT ZURN, SMITH
HA E 114*154
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
P001
PL
U M B
IN
G N O
TE
S, L
EG
EN
D, S C H
ED
U
LE
S
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
GAS WATER HEATER SCHEDULE
ITEM
CAPACITY
(GALLONS)
RECOVERY (GPH)
@ 100°F FUEL
MAX. INPUT
(BTU/HR)
BASIS OF
DESIGN MODEL NO. REMARKS
WH*1 130 576 NATURAL GAS 499,900 A. O. SMITH BTH*500A 1, 2
PLUMBING FIXTURE SCHEDULE
ITEM FIXTURE TYPE FIXTURE DESCRIPTION
HOT
WATER
COLD
WATER WASTE VENT
MOUNTING HEIGHT /
REMARKS / NOTES
EEW EMERGENCY EYE
WASH
WALL MOUNTED EMERGENCY EYE WASH WITH 11*1/2" DIAMETER STAINLESS STEEL BOX, HEAVY DUTY CAST ALUMINUM WALL BRACKET, AND TWO SPRAY*TYPE SPRAY HEADS WITH INTERNAL FLOW CONTROL AND FILTER TO
REMOVE IMPURITIES FROM THE WATER FLOW.
* FIXTURE: GUARDIAN MODEL NO. G1814 OR APPROVED EQUAL BY BRADLEY, SPEAKMAN, OR T&S.
1" WALL MOUNTED /
ORIFICE HEIGHT: 39"
HB HOSE BIBB
(INTERIOR)
BRONZE QUARTER TURN NONFREEZE AUTOMATIC DRAINING HYDRANT WITH STAINLESS STEEL FACE, HOSE CONNECTION, INTEGRAL VACUUM BREAKER AND DUAL CHECK VALVE, WHEEL HANDLE AND STAINLESS STEEL BOX WITH COVER OPENING. FIXTURE SHALL BE J.R. SMITH MODEL NO. 5519 OR APPROVED EQUAL.
3/4" 18" A.F.F.
HB/E HOSE BIBB
(EXTERIOR)
BOX TYPE NARROW WALL WARM CLIMATE HYDRANT WITH CHROME PLATED FACE, HOSE CONNECTION HAVING INTEGRAL ASSE 1011 VACUUM BREAKER, 360 SWIVEL INLET CONNECTION, AND 20 GAUGE STAINLESS STEEL BOX.
FIXTURE SHALL BE J.R. SMITH MODEL NO. 5518 OR APPROVED EQUAL
3/4" 18" A.F.G.
IMB ICE MAKER
CONNECTION BOX
OATEY MODEL NO. 38608 ICEMAKER BOX COMPLETE WITH QUARTER TURN BRASS HAMMER VALVE OR APPROVED
EQUAL.
1/2" 36" BOX HEIGHT
P*1 WATER CLOSET *
FLOOR MOUNTED
* FLUSH VALVE
FLOOR MOUNTED, FLOOR OUTLET, VITREOUS CHINA, SIPHON JET WATER CLOSET WITH ELONGATED BOWL (DESIGNED FOR A 1.28 GPM FLUSH CYCLE) AND HARD WIRED SENSOR OPERATED FLUSH VALVE. WATER CLOSET SHALL BE FITTED WITH OPEN FRONT SEAT WITHOUT COVER, FLUSH MECHANISM, AND A WHEEL HANDLE ANGLE
SUPPLY.
* FIXTURE: KOHLER MODEL NO. K4405 OR APPROVED EQUAL BY TOTO, ELJER, OR AMERICAN STANDARD.
* FLUSH VALVE: SLOAN MODEL NO. ECOS 8111%1.28 OR APPROVED EQUAL.
* SEAT: AMERICAN STANDARD MODEL NO. 5905.100 EXTRA HEAVY DUTY OPEN FRONT LESS COVER OR EQUAL.
1 1/4" 3" 2" FLOOR MOUNTED / 15"
RIM HEIGHT / FLUSH
VALVE
P*1A ADA WATER
CLOSET * FLOOR
MOUNTED *
FLUSH VALVE
FLOOR MOUNTED, FLOOR OUTLET, VITREOUS CHINA, SIPHON JET WATER CLOSET WITH ELONGATED BOWL (DESIGNED FOR A 1.28 GPM FLUSH CYCLE) AND HARD WIRED SENSOR OPERATED FLUSH VALVE. WATER CLOSET SHALL BE FITTED WITH OPEN FRONT SEAT WITHOUT COVER, FLUSH MECHANISM, AND A WHEEL HANDLE ANGLE
SUPPLY.
* FIXTURE: KOHLER MODEL NO. K4405 OR APPROVED EQUAL BY TOTO, ELJER, OR AMERICAN STANDARD.
* FLUSH VALVE: SLOAN MODEL NO. ECOS 8111*1.28 OR APPROVED EQUAL.
* SEAT: AMERICAN STANDARD MODEL NO. 5905.100 EXTRA HEAVY DUTY OPEN FRONT LESS COVER OR EQUAL
1 1/4" 3" 2" ADA COMPLIANT /
FLOOR MOUNTED /
16*1/2" RIM HEIGHT /
FLUSH VALVE
P*2 WATER CLOSET *
WALL MOUNTED *
FLUSH VALVE
WALL MOUNTED, WALL OUTLET, VITREOUS CHINA, SIPHON JET WATER CLOSET WITH ELONGATED BOWL (DESIGNED FOR A 1.28 GPM FLUSH CYCLE) AND HARD WIRED SENSOR OPERATED FLUSH VALVE. WATER CLOSET SHALL BE FITTED WITH OPEN FRONT SEAT WITHOUT COVER, FLUSH MECHANISM, AND A WHEEL HANDLE ANGLE SUPPLY.
PROVIDE WITH CARRIERS BY ZURN OR APPROVED EQUAL.
* FIXTURE: KOHLER MODEL NO. K4325 OR APPROVED EQUAL BY TOTO, ELJER, OR AMERICAN STANDARD.
* FLUSH VALVE: SLOAN MODEL NO. ECOS 8111*1.28 OR APPROVED EQUAL.
* SEAT: AMERICAN STANDARD MODEL NO. 5905.100 EXTRA HEAVY DUTY OPEN FRONT LESS COVER OR EQUAL.
1 1/4" 3" 2" WALL MOUNTED / 15"
RIM HEIGHT / FLUSH
VALVE
P*2A ADA WATER
CLOSET * WALL
MOUNTED *
FLUSH VALVE
WALL MOUNTED, WALL OUTLET, VITREOUS CHINA, SIPHON JET WATER CLOSET WITH ELONGATED BOWL (DESIGNED FOR A 1.28 GPM FLUSH CYCLE) AND HARD WIRED SENSOR OPERATED FLUSH VALVE. WATER CLOSET SHALL BE FITTED WITH OPEN FRONT SEAT WITHOUT COVER, FLUSH MECHANISM, AND A WHEEL HANDLE ANGLE SUPPLY.
PROVIDE WITH CARRIERS BY ZURN OR APPROVED EQUAL.
* FIXTURE: KOHLER MODEL NO. K4325 OR APPROVED EQUAL BY TOTO, ELJER, OR AMERICAN STANDARD.
* FLUSH VALVE: SLOAN MODEL NO. ECOS 8111*1.28 OR APPROVED EQUAL.
* SEAT: AMERICAN STANDARD MODEL NO. 5905.100 EXTRA HEAVY DUTY OPEN FRONT LESS COVER OR EQUAL.
1 1/4" 3" 2" ADA COMPLIANT / WALL
MOUNTD / 16*1/2" RIM
HEIGHT / FLUSH VALVE
P*3 URINAL * FLUSH
VALVE
WALL HUNG, VITREOUS CHINA, SIPHON JET URINAL (DESIGNED FOR A 1.0 GPM FLUSH CYCLE), AND WITH EXTENDED BASIN (MINIMUM 13" TO WALL), 2" OUTLET, 3/4" TOP SPUD, AND WALL HANGERS. THE URINAL SHALL BE FITTED WITH A 3/4" (11*1/2" ROUGHING) FLUSHOMETER AND BACKPLATE. URINAL SHALL BE MOUNTED PER ADA REQUIREMENTS.
* FIXTURE: AMERICAN STANDARD MAYBROOK MODEL NO. 6581.015 OR APPROVED EQUAL BY KOHLER, CRANE, ELJER.
* FLUSH VALVE: SENSOR OPERATED HARD WIRED SLOAN MODEL NO. ECOS 8186 OR APPROVED EQUAL BY
AMERICAN STANDARD, KOHLER, CRANE.
3/4" 2" 1 1/2" ADA COMPLIANT / WALL
MOUNTED / 17" RIM
HEIGHT
P*4 LAVATORY * OVAL
UNDERCOUNTER
UNDERCOUNTER 17" X 14" OVAL, VITREOUS CHINA BATHROOM SINK, WITH MOUNTING ASSEMBLY AND CONCEALED FRONT OVERFLOW. COORDINATE FINISH COLOR WITH ARCHITECT. PROVIDE WITH DECK MOUNTED CENTER SET FAUCET WITH HARD WIRED SENSOR OPERATION. TRIM TO INCLUDE PERFORATED GRID STRAINER AND ADA OFFSET DRAIN FOR HANDICAPPED MODEL, 1*1/4" CAST BRASS (17 GAUGE) P*TRAP AND LOOSE KEY ANGLE SUPPLIES. DRAIN, TRAP, AND SUPPLIES SHALL BE INSULATED BY MEANS OF A LAY*SHIELD. SEE DETAIL.
* FIXTURE: TOTO MODEL NO. LT569.
* FAUCET: SENSOR OPERATRED HARD WIRED SLOAN MODEL NO. EBF*187*4 OR APPROVED EQUAL BY MOEN, CHICAGO, KOHLER.
1/2" 1/2" 1 1/2" 1 1/2" ADA COMPLIANT /
UNDERCOUNTER
P*6 MOP SINK 24"x36" MOP BASIN WITH 10" HIGH SIDES AND INTEGRAL 3" CHROME PLATED DRAIN WITH SEAL FOR CONNECTION TO WASTE PIPE. MOP BASIN SHALL BE FITTED WITH ALUMINUM BUMPER GUARDS WITH VINYL INSERT, A CHROME PLATED FAUCET WITH VACUUM BREAKER, AND HOSE BRACKET. PROVIDE WITH FAUCET MOUNTED ON WALL 36
INCHES ABOVE FINISHED FLOOR.
* FIXTURE: FLORESTONE MODEL NO. MSR*3624 OR APPROVED EQUAL BY STERN WILLIAMS OR FIAT.
* FAUCET: CHICAGO MODEL NO. 897*CP OR APPROVED EQUAL.
3/4" 3/4" 3" 2" FLOOR MOUNTED
P*7 BREAK ROOM
SINK *
UNDERCOUNTER
SINGLE BOWL SINK, 18 GAUGE, TYPE 304 NICKEL BEARING STAINLESS STEEL UNDERMOUND SINK WITH 23"x17" OVERALL DIMENSIONS. PROVIDE WITH DECK MOUNTED GOOSENECK FAUCET, 2*HOLE ON 4" CENTERS. SINK SHALL BE PROVIDED WITH CAST BRASS P*TRAP (17 GAUGE), WHEEL HANDLE ANGLE SUPPLIES, AND DRAIN, WITH BASKET
STRAINER.
* SINK: ELKAY CELEBRITY MODEL NO. ELU2317 OR APPROVED EQUAL BY JUST, KOHLER, ADVANCE TABCO
* FAUCET: AMERICAN STANDARD MODEL NO. 6409.170 OR APPROVED EQUAL BY ELKAY, SYMMONS, MOEN, DELTA
* P*TRAP: EBC OR APPROVED EQUAL BY MCGUIRE, DEARBORN
* SUPPLIES: BRASS CRAFT OR APPROVED EQUAL BY MCGUIRE.
1/2" 1/2" 1 1/2" 1 1/2" UNDERCOUNTER
P*8 BREAK ROOM
SINK
SINGLE BOWL SINK, 20 GAUGE, TYPE 304 NICKEL BEARING STAINLESS STEEL, SELF*RIMMING SINK WITH 31"x22" OVERALL DIMENSIONS. PROVIDE WITH FAUCET, 2*HOLE ON 4" CENTERS. SINK SHALL BE PROVIDED WITH CAST BRASS P*TRAP (17 GAUGE), WHEEL HANDLE ANGLE SUPPLIES, AND DRAIN, WITH BASKET STRAINER.
* SINK: ELKAY CELEBRITY MODEL NO. CR3122 OR APPROVED EQUAL BY JUST, KOHLER, ADVANCE TABCO
* FAUCET: ELKAY MODEL NO. LKD24898BH OR APPROVED EQUAL BY SYMMONS, MOEN, DELTA
* P*TRAP: EBC OR APPROVED EQUAL BY MCGUIRE, DEARBORN
* SUPPLIES: BRASS CRAFT OR APPROVED EQUAL BY MCGUIRE.
1/2" 1/2" 1 1/2" 1 1/2" COUNTERTOP
P*9 ADA CHANGING
ROOM SHOWER
ADA COMPLIANT ACRYLIC SHOWER, WHITE IN COLOR, WITH TEXTURED BOTTOM, 2 SHELVES, FOLD DOWN WOOD GRAIN SEAT, CHROME CURTAIN ROD, AND ANTIMICROBIAL GREEN CURTAIN. SHOWER SHALL INCLUDE WITH 12", 18", AND 27" GRAB BARS OF 1*1/2" DIAMETER. PROVIDE WITH ADA SHOWER FAUCET TRIM, INCLUDING SOLID BRASS HAND*HELD SHOWERHEAD (DESIGNED AT 2.0 GPM MAX) AND LEVER, AND MONITOR 17 SERIES PRESSURE BALANCED BATH MIXING VALVE WITH SCALD*GUARD OR EQUAL. LEVER SHALL CONSIST OF VOLUME CONTROL HANDLE AND TEMPERATURE ADJUSTMENT DIAL. PROVIDE WITH CAST IRON SHOWER DRAIN WITH 6" BRONZE TOP
STRAINER AND 2" NO*HUB OUTLET.
* SHOWER: AQUA GLASS MODEL NO. 634137 DL OR APPROVED EQUAL BY DELTA, AQUARIUS, KOHLER, OR FIAT.
* TRIM: DELTA MODEL NO. T17294*I OR APPROVED EQUAL BY MOEN, KOHLER, OR CHICAGO.
* DRAIN: ZURN MODEL NO. Z415B OR APPROVED EQUAL BY J.R. SMITH, GRAINGER, OR SIOUX CHIEF.
1/2" 1/2" 3" 2" COORDINATE EXACT
LOCATION AND HEIGHT
OF SHOWER TRIM WITH
ARCHITECT
P*10 BREAK ROOM
SHOWER
ONE PIECE SHOWER, WHITE IN COLOR, WITH HIGH GLOSS ACRYLIC SURFACE AND MULTI*LEVEL STORAGE. PROVIDE WITH SHOWER FAUCET TRIM, INCLUDING SOLID BRASS SHOWERHEAD (DESIGNED AT 2.0 GPM MAX) AND LEVER, AND MONITOR 17 SERIES PRESSURE BALANCED BATH MIXING VALVE WITH SCALD*GUARD OR EQUAL. LEVER SHALL CONSIST OF VOLUME CONTROL HANDLE AND TEMPERATURE ADJUSTMENT DIAL. PROVIDE WITH CAST IRON
SHOWER DRAIN WITH 6" BRONZE TOP STRAINER AND 2" NO*HUB OUTLET.
* SHOWER: AQUA GLASS MODEL NO. 213637 CC 00 OR APPROVED EQUAL BY DELTA, AQUARIUS, KOHLER, OR FIAT.
* TRIM: DELTA MODEL NO. T17294 OR APPROVED EQUAL BY MOEN, KOHLER, OR CHICAGO.
* DRAIN: ZURN MODEL NO. Z415B OR APPROVED EQUAL BY J.R. SMITH, GRAINGER, OR SIOUX CHIEF.
1/2" 1/2" 3" 2" COORDINATE EXACT
LOCATION AND HEIGHT
OF SHOWER TRIM WITH
ARCHITECT
P*11 ADA SHOWER
BASE AND TRIM
ADA COMPLIANT SHOWER FAUCET BASE AND TRIM, INCLUDING SOLID BRASS HAND*HELD SHOWERHEAD (DESIGNED AT 2.0 GPM MAX) AND LEVER, AND MONITOR 17 SERIES PRESSURE BALANCED BATH MIXING VALVE WITH SCALD*GUARD OR EQUAL. LEVER SHALL CONSIST OF VOLUME CONTROL HANDLE AND TEMPERATURE ADJUSTMENT DIAL. SHOWER BASE SHALL BE WHITE, SLIP RESISTANT DESIGN, 60" X 36" DIMENSIONS (CENTER SET DRAIN OPENING), HIGH GLOSS ACRYLIC BACKED WITH SOLID SURFACE AND HIGH DENSITY URETHANE FOAM REINFORCEMENT. PROVIDE BASE WITH CENTER SET CAST IRON SHOWER DRAIN WITH 6" BRONZE TOP STRAINER
AND 2" NO*HUB OUTLET.
* TRIM: DELTA MODEL NO. T17294*I OR APPROVED EQUAL BY MOEN, KOHLER, OR CHICAGO.
* BASE: AMERICAN STANDARD CIENCIA MODEL NO. 6036S1.STC.020 OR APPROVED EQUAL BY AQUA GLASS, KOEHLER, OR MAAX.
* DRAIN: ZURN MODEL NO. Z415B OR APPROVED EQUAL BY J.R. SMITH, GRAINGER, OR SIOUX CHIEF.
1/2" 1/2" 3" 2" SHOWER TRIM ONLY /
COORDINATE EXACT
LOCATION AND HEIGHT
OF SHOWER TRIM WITH
ARCHITECT
P*12 ELECTRIC WATER
COOLER *
BI*LEVEL
BI*LEVEL, SELF*CONTAINED, WALL HUNG ELECTRIC REFRIGERATED, VANDAL*RESISTANT, ADA COMPLIANT WATER
COOLER.
*FIXTURE: ELKAY MODEL NO. EZS8 OR APPROVED EQUAL BY OASIS, HALSEY TAYLOR.
1/2" 2" 1 1/2" BI*LEVEL / 38" AND 33"
ORIFICE HEIGHTS / ADA
COMPLIANT
P*13 EXTERIOR WATER
FOUNTAIN
VANDAL*RESISTANT, ONE*PIECE, CHROME*PLATED, WALL*MOUNTED STEEL FOUNTAIN WITH TEXTURED POWDER COAT FINISH AND STAINLESS STEEL CONTOURED*FORMED BASIN WITH ROUNDED CORNERS AND EDGES. WATER FOUNTAIN SHALL HAVE SINGLE SELF*CLOSING, VANDAL*RESISTANT PUSHBUTTON, AUTOMATIC STREAM HEIGHT
REGULATOR, AND IN*LINE INLET STRAINER.
* FIXTURE: ELKAY MODEL NO. LK4405 OR APPROVEL EQUAL BY OASIS OR HALSEY TAYLOR.
1/2" 2" 1 1/2" ADA COMPLIANT /
ORIFICE HEIGHT: 35*1/4"
ELECTRIC WATER HEATER SCHEDULE
ITEM AREA SERVED
CAPACITY
(GALLONS)
RECOVERY (GPH)
@ 70°F FUEL
ELEMENT
WATTAGE
BASIS OF
DESIGN
MODEL
NO. REMARKS
WH*2 ENHANCED
VENDING AREA
6 8 ELECTRIC 1.5 KW A. O. SMITH DEL*6 1, 2
HOT WATER CIRCULATION PUMP SCHEDULE
ITEM SERVICE HP
FLOW
RATE
(GPM)
BASIS OF
DESIGN MODEL NO. REMARKS
HWC*1 HOT WATER
CIRCULATION
1/12 2.0 BELL &
GOSSETT
PL*30 1, 2
NOTES:
1. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL REQUIREMENTS.
2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
NOTES:
1. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL REQUIREMENTS.
2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
NOTES:
1. SEE ELECTRICAL DRAWINGS FOR ELECTRICAL REQUIREMENTS.
2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
NOTES:
1. PROVIDE ANGLE STOP VALVES, SUPPLY TUBING, P*TRAPS, ESCUTCHEON PLATES, CARRIERS, ETC., FOR COMPLETE INSTALLATION.
2. ALL SUPPLY AND WASTE LINES SHALL BE CONCEALED IN ADJACENT WALL, FLOOR AND CEILING, UNLESS NOTED OTHERWISE.
FLOOR CLEANOUTSINGLE TWO*WAY CLEANOUTWALL CLEAN OUT
AT END OF LINE
OMIT EXTENSION
CLEAN OUT
FINISHED FLOORFINISHED GRADEFINISHED WALL
ACCESS PLATE
CLEAN OUT
CLEAN OUT
FINISHED FLOOR /
FLOW
FOR CLEANOUT AT END OF
LINE, PLUG WYE AT THIS POINT.
2'*0" MIN.
EXTENSION LENGTH AS REQUIRED
FIN. GRADE OR
PAVING
1" (YARD OR
GRADE
APPLICATION
ONLY)
2'*0"X2'*0"X1'*0" DEEP (MIN)
POURED CONCRETE PAN
SEE PLAN FOR
CONTINUATION &
SIZING (TYPICAL)
LONG SWEEP BEND
(REDUCING TYPE WHERE
REQUIRED)
CLEANOUT FITTING (SEE SCHEDULE)
WHEN CLEANOUT IS NOT IN A PAVED AREA,
PROVIDE 2'*0"X2'*0"X6" DEEP (MIN) CONCRETE
CLEANOUT BOX W/6X6X1/4 WIRE MESH (BOX IS
INDEPENDENT OF PIPE AND THEREFORE IS FREE
TO MOVE WITH THE SETTLEMENT OF GRADE).
SLOPE CONCRETE TO GRADE IN SOIL
APPLICATION. POUR PAD FLUSH WITH PAVING IN
PAVING LOCATION.
PROVIDE "HEAVY DUTY" CAST
IRON COVER FOR ALL EXTERIOR
CLEANOUTS
6" MAX.
FINISHED
WALL
(TYPICAL)
CAST ESCUTCHEON
MOLDED VINYL INSULATION)
VALVE. (MODEL 102*W, WHITE
P*TRAP AND EACH SUPPLY
HANDI LAV*GUARD KIT FOR
27" MIN.
TRAP
OFFSET
32"*34"
HANDICAPPED
LAVATORY (SEE
FLOOR PLAN FOR
LOCATIONS)
TRAPEZE HANGER ASSEMBLY
NOTES :
PIPE CLAMP, TYP.
HANGER ROD, TYP.
PIPES,
SEE
NOTE 2
TYPICAL MOUNTING DETAIL OF PIPING ON
TRAPEZE HANGER.
REFER TO THE PLANS FOR NUMBER AND SIZE
OF PIPES.
PROVIDE DIELECTRIC SHIELDS FOR COPPER
PIPING SUPPORTED IN TRAPEZE.
SEE SEISMIC NOTES FOR ADDITIONAL BRACING
REQUIREMENTS.
NOTE:
AREAS. SIZE AS REQUIRED.
REMOVAL OF ALL PIPE CAULK MATERIALS.
OF ANY CAULKING MATERIALS SHALL REQUIRE THE
REVIEW. FAILURE TO COMPLY PRIOR TO INSTALLATION
PROVIDE DATA SHEETS FOR CAULKING MATERIALS FOR
OMIT PIPE INSULATION
INSIDE PIPE SLEEVE
PER U.L. 1479 AND ASTM
THICKNESS AND MATERIAL
FIRE SAFING
E814. (TYPICAL)
PROVIDE CAULKING*
MATERIAL
PIPE
BRASS ESCUTCHEON FOR FINISHED
PROVIDE CHROME PLATED CAST
AND LOCATIONS)
DRAWINGS FOR RATINGS
RATED WALL (SEE ARCH
INSULATION (AS
APPLICABLE)
SIZE SLEEVE AS REQUIRED TO
MAINTAIN THE
U.L. LISTING AND IN ACCORDANCE
WITH
SEALANT MFR REQT'S
FLOOR DRAIN
NOTE:
INSTALL TRAP PRIMER DISTRIBUTION UNIT
IN CHASE WALL PROVIDE POSITIVE SLOPE
TO TRAP CONNECTION.
1/2" STRAINER
TRAP PRIMER
DISTRIBUTION
UNIT PPP MODEL DU*4
ROUTE TO TRAP PRIMER
CONNECTION ON FLOOR
DRAIN
COLD WATER LINE
COLD WATER SUPPLY
PRODUCTS UNDER*LAV
PRECISION PLUMBING
BUSHING
3" TEE WITH 1/2"
FINISHED FLOOR
FLOOR DRAIN
TRAP PRIMER
FINISHED WALL
LAVATORY
ANGLE STOP
TRAP
SLOPE TO FLOOR DRAIN
AND UNDER FLOOR
1/2" PIPING IN WALL
IF LAVATORY IS NOT
PRESENT IN AREA OF
TRAP PRIMER VALVE,
TIE INTO NEAREST
DOMESTIC COLD
WATER LINESUPPLY TO FIXTURE
SUPPLY RISER
TYPE "A" WATER HAMMER ARRESTOR
(UNO), BY PPP INC., ZURN OR
APPROVED EQUAL. INSTALL AT EACH
FIXTURE, HOSE BIB & WATER HEATER ON
HOT AND COLD WATER PIPING.
DIELECTRIC UNIONS (TYP.)
BALL VALVE (TYP.)
HOT WATER TO
FIXTURES, PROVIDE
THERMOSTATIC
MIXING VALVE TO
TEMPER HOT WATER
TO 100F
(SEE MIXING VALVE
DETAIL)
SUPPLY
COLD WATER
2"x 4"
PLASTIC BLOCKS
TO FLOOR DRAIN
ROUTE DRAIN FULL SIZE
4" MIN.
PAN TO DRAIN POINT
RELIEF VALVE
ASME T & P RELIEF
VALVE*PIPE DISCHARGE
FULL SIZE TO SAFETY PAN
HEAT TRAP (TYP.)
PROVIDE POSITIVE SLOPE
TRAP PRIMER CONNECTION
TIE ROD
CLEVIS HANGER
TRAP
FLUSH WITH FLOOR
5" STRAINER SET
PROVIDE SQUARE TOP
FOR TILE FLOORS
SLAB
FLOOR
SLOPED
CONTRACTOR SHALL PROVIDE
4"Ø
CONCENTRIC DIRECT VENT
DUCT THRU WALL. PROVIDE
MANUFACTURER'S
RECOMMENDED VENT CAP.
CONTRACTOR SHALL
PROVIDE
MANUFACTURER'S
OPTIONAL INTAKE /
EXHAUST CAPPING
DEVICE AND
DUCTWORK.
ROOF
CONTRACTOR SHALL PROVIDE
TEE
CONNECTION FOR
MANUFACTURER'S
BAROMETRIC DAMPER.
CONTRACTOR
SHALL INSTALL.
WH NOTE:
CONTRACTOR SHALL PROVIDE
ALL NEW VENT DUCTWORK.
TYPE B VENTING
CHECK VALVE
FACE OF PRESSURE GAUGES TO BE TURNED SO AS TO BE ABLE TO BE READ
STANDING AT FLOOR LEVEL.
COORDINATE TIMER SETTINGS WITH ON*SITE MAINTENANCE STAFF.
SET AQUASTAT CONTROL FOR 20°F DROP IN RETURN LINE.
NOTES:
BALL
VALVE
1/2" SHUT*OFF COCK
REDUCING TEE
PRESSURE GAGE
STRAINER
UNION
UNION
PLAN VIEW
TIMER AND AQUASTAT
MOTOR
HWC*1
REDUCING TEE
1/4" SHUT*OFF COCK
PRESSURE GAGE
SET TO 2.0 GPM.
BALANCING VALVE BY B&G,
FLOW METER AND
MANUAL IN*LINE
BALL VALVE
1.
2.
3.
(TYP.)
FLANGE
UNION OR
(TYP.)
PRESSURE GAUGE
APPROVED FOR VERTICAL
BACKFLOW PREVENTER
STRAINER
INSTALLATION
DOUBLE CHECK
SERVICE
HOSE BIBB
SHUT*OFF
VALVE
3" WATER
FIN. FLR.
WATTS N223SB OR EQUAL
65 OUTLET PRESSURE
3" STRAINER
3" FULL PORT BALL VALVE
WATTS FBV OR EQUAL
3" PRESSURE REDUCING VALVE (PRV)
(TYP.)
VALVE
3/4" DRAIN
(TYP.)
3"
UNION
RETURN
TO HEATER
TEMPERED
WATER
OUT
HOT SUPPLY COLD SUPPLY
TEMPERED
WATER
RETURN
TURN LEAD DOWN INTO
STACK (CANNOT RESTRICT
FLOW OF AIR) VENT CAP
ROOFING INSULATION
ROOF CONSTRUCTION
MIN. 12"
ABOVE ROOF
MIN. 12"
SLEEVE ROOF CONSTRUCTION
AS REQUIRED (PROVIDE FIRE
RATED CAULKING WHEN
REQUIRED BY LOCAL CODES)
INCREASER (WHEN REQUIRED)
VENT STACK
P*TRAP
1*1/2"
3" x 1*1/2"
1" AIR GAP
CONDENSATE
DRAIN LINE BY
OTHERS
SINGLE BOWL
HAND WASHING
SINK
THE SCOPE OF WORK IS DIVIDED INTO TWO
SEPARATE DESIGNATIONS; DKFX:11*1122A FOR ADD
AND DKFX"11*1122B FOR REPAIR. "ADD" WORK IS
CONSIDERED ALL WORK RELATED TO NEW
BUILDING ADDITIONS. "REPAIR" WORK IS
CONSIDERED ALL WORK RELATED TO OR IN THE
EXISTING FACILITY.
ADD WORK IS INDICATED WITH
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
P002
PL
U M B
IN
G
DE
TA
IL
S
M
AU
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
4SCALE: NOT TO SCALEP002
11 CLEANOUT DETAIL
SCALE: NOT TO SCALEP002
9 GRADE CLEANOUT DETAIL
SCALE: NOT TO SCALEP002
6 P*TRAP INSULATION DETAIL WITH ADA CLEARANCES
SCALE: NOT TO SCALEP002
15 PIPE HANGER INSTALLATION DETAIL
SCALE: NOT TO SCALEP002
7 PIPE THRU RATED ASSEMBLY DETAIL
SCALE: NOT TO SCALEP002
2 TRAP PRIMER DETAIL
SCALE: NOT TO SCALEP002
5 TRAP PRIMER VALVE DETAIL
SCALE: NOT TO SCALEP002
1 WATER HAMMER ARRESTOR DETAIL
SCALE: NOT TO SCALEP002
14 WATER HEATER DETAIL
SCALE: NOT TO SCALEP002
8 FLOOR DRAIN DETAIL
SCALE: NOT TO SCALEP002
16 GAS WATER HEATER VENTING DETAIL
SCALE: NOT TO SCALEP002
10 IN*LINE CIRCULATING PUMP DETAIL
SCALE: NOT TO SCALEP002
12 DOMESTIC WATER RISER DETAIL
SCALE: NOT TO SCALEP002
4 MIXING VALVE DETAIL
SCALE: NOT TO SCALEP002
3 VENT THROUGH ROOF DETAIL
SCALE: NOT TO SCALEP002
13 SINK HUB DRAIN DETAIL
1. GENERAL CONTRACTOR (GC) IS RESPONSIBLE FOR COORDINATING ALL
FIXTURES, FURNITURE & EQUIPMENT (FF&E) REQUIREMENTS FOR THIS PROJECT.
REFER TO FF&E SCHEDULE FOR FF&E SCOPE OF WORK.
2. SHOULD BID ALTERNATE NUMBER 3 * OUTDOOR PLAY AREA NOT BE SELECTED
BY THE GOVERNMENT THEN THE PLAY AREA EQUIPMENT LISTED IN THE FF&E
SCHEDULE WILL NOT BE A PART OF THE FF&E SCOPE OF WORK.
3. REFER TO BHE01 AND SPECIFICATION SECTION 34 77 39.00 10 INBOUND
BAGGAGE CONVEYOR, 34 77 39.00 20 OUTBOUND BAGGAGE CONVEYOR AND 34
77 39 BAGGAGE CONVEYING EQUIPMENT FOR SCOPE OF BAGGAGE HANDLING
EQUIPMENT (BHE) WORK.
4. LOCATION(S), SIZES AND ELECTRICAL REQUIREMENTS FOR BHE ARE
APPROXIMATE. GC SHALL VERIFY AND COORDINATE ALL REQUIREMENTS WITH
SELECTED BHE MANUFACTURER ONCE THE SYSTEM HAS BEEN SELECTED. GC
SHALL NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES. REFER TO MEP FOR REQUIREMENTS WHICH ARE PART OF THE
BASE BID AND IN THE GC SCOPE OF WORK.
5. REFER TO IDS DRAWINGS AND SPECIFICATION SECTION 28 20 00.00 20
ELECTRONIC SECURITY SYSTEMS (ESS), COMMERCIAL FOR SCOPE OF IDS WORK.
6. REFER TO AVS DRAWINGS FOR SCOPE OF AVS WORK.
7. REFER TO WF01 FOR SCOPE OF WIFI WORK.
ANCILLARY GENERAL NOTES
FACP
A
B
C
H
3 4 5 5.2 7 7.1
N
M
L.8
L
K
J
G
F
E
D
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P050
PL
U M B
IN
G
DE
M O
LI
TI
O N P
LA
N
N O
RT
H S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P050
1 PLUMBING DEMOLITION PLAN NORTH
PLUMBING KEYED NOTES
DEMOLISH ALL DOMESTIC, SANITARY, AND VENT PIPING IN
HATCHED AREA. SEE SHEET M050 FOR DEMOLITION OF EXISTING
NATURAL GAS PIPING AND METER.
(THIS SHEET ONLY)
NORTH
7.9 8 9 9.3 9.7 10 11
N
M
L.8
L
K
J
G
F
E
D
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P051
PL
U M B
IN
G
DE
M O
LI
TI
O N P
LA
N
S O U
TH
S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P051
1 PLUMBING DEMOLITION PLAN SOUTH
PLUMBING KEYED NOTES
DEMOLISH ALL DOMESTIC, SANITARY, AND VENT PIPING IN
HATCHED AREA. EXISTING NATURAL GAS PIPING TO REMAIN, SEE
SHEET M051.
(THIS SHEET ONLY)
SOUTH
A
B
C
H
3 4 5 5.2 7 7.1
GARAGE
COMM.
WOMEN
MEN
READING ROOM
OIC OFFICE
SUPT. OFFICE
STORAGE
CONFERENCE
TRAINING
STO.
COPY AREA
ADMIN
LOUNGE LOBBY
PASSENGER
LOUNGE
BREAK ROOM
WOMENS
OPS NCOIC
OFFICE
VESTIBULE
SECURE GATE
CORRIDOR
DEPARTURE
GATE 2
SPEC. CAT
LOUNGE
UNISEX
SHOWER/
CHANGING
ROOM
BUSINESS
CENTER
COMM.
BAGGAGE
SCREENING
FUNDS
SUPR.
FLIGHT
CHECK#IN
COUNTER
DISPATCH
CENTRAL
LOBBY
P*4
P*7
P*4
1 1/2" C
/2
C
/2
C
/4
H
1 1/2" C
3/4" H
3/4" H
/4
H
MECH./ELEC.
OPEN OFFICE
ADMIN LOBBY
TV ROOM
GAME ROOM
BAGGAGE
BUILD UP
DEPARTURE
GATE 1
CARTS
P*8
1" C
2" C
1" H
FD
FD
P*1A
P*1
P*1
/4
H
W R
1" HWR3/4" HWR
HB
HB/E
HB/E
IMB
1/2" C
P*4
P*4
COMM.
CLOSET
ALCOVE
MENS
CORRIDOR
FD
P*8
3/4" HWR
P*4
P*4 P*3
P*1 P*1
P*1 P*10
P*10
1" H
P*11
N
M
L.8
L
K
J
G
F
E
P *1
D
HB/E
CORRIDOR
COVERED
CANOPY AREA
1 1/4" C
1 1/4" C
C
/4
H
/2
C
H
/4
H
W R
/4
C
1 1/4" C 3/4" C
/4
H
W R
/4
H1 1/4" C
3/4" C 3/4" C
3/4" H
3/4" C
IMB
EEW
1" C
FD
FD
FD
FD
P*12
P*4
P*4 P*3
P*1
P*1 P*10
P*1
P*10
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P101
DO
M
ES
TI
C P
LU
M B
IN
G
RE
N O
VA
TI
O N P
LA
N
N O
RT
H S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P101
1 DOMESTIC PLUMBING RENOVATION PLAN NORTH
NORTH
SIDE
1. WHERE PIPE SIZE IS NOT SHOWN REFER TO FIXTURE SCHEDULE
FOR CONNECTION SIZE.
2. PROVIDE HAMMER ARRESTOR AT EVERY FIXTURE. SEE DETAIL.
3. ROUTE 1/2" COLD WATER TRAP PRIMER PIPING TO ALL FLOOR
DRAINS FROM COLD WATER LINE AT NEAREST FIXTURE. SEE
DETAILS.
PLUMBING KEYED NOTES
PROVIDE CIRCUIT SETTER ON HOT WATER RECIRCULATION LINE
SET AT 0.5 GPM.
PROVIDE CIRCUIT SETTER ON HOT WATER RECIRCULATION LINE
SET AT 1.5 GPM.
(THIS SHEET ONLY)
PLUMBING GENERAL NOTES
SCALE:P101
2 DOMESTIC PLUMBING RISER * 129/131
NOT TO SCALE
VESTIBULE
CARTS
ENHANCED
VENDING AREA
VESTIBULE
CAR RENTAL
PSC
FAMILY
LOUNGE
RESTROOM
CRIB ROOM
PLAY ROOM
ELEC.
ARRIVAL
WAITING
SPRINKLER
RISER ROOM
BAGGAGE
CLAIM
MEN
WOMEN
MECHANICAL
MEN
WOMEN
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
CUSTOMS
SECURITY
SCREENING
SECURE GATE
CORRIDOR
DEPARTURE
GATE 2
MEN
WOMEN
DEPARTURE/ARRIVAL
GATE 3
BAGGAGE
BREAKDOWN
CENTRAL
LOBBY
P*4
P*4
P*4P*4
P*4
P*4
P*3
P*3
P*3
P*1A P*1 P*1 P*1
P*3P*3 P*1P*1A P*4 P*4
P*4 P*4P*4
P*4
3" C
1 1/2" C
3" C
WH*1
7.9 8 9 9.3 9.7 10 11
C
3" C3" C
/2
C
C
P*12
P*12
P*12
/2
C
H
/2
H
1" H1 1/4" H
H
COMM.
CORRIDOR
3/4" C
LOST & FOUND
P*7
3" C 3" C
/2
C
/2
C
HB
FD FD
FDFD
FD
FD
FD FD
FD
FD FD
FD FD
FD
FD
P*4
P*4
P*4
P*3
WH*2
P*1A
HB/E
HB/E
P*2A
P*2
P*2
P*2
P*2
P*2
P*2
P*2A
P*2
P*2
P*2A
P*2
P*2
P*2
P*2
P*4
IMB
3/4" C
HWC*1
P*13
1" C
P*7
P*3
P*2
P*2
P*2A
P*3
P*4
3/4" C
/4
H
FD
H
P*9 P*9
SEE CIVIL
DRAWINGS FOR
CONTINUATION
N
M
L.8
L
K
J
G
F
E
D
HB/E
/4
C
HB/E
P*6 3/4" C
/4
H
/4
H
1" C1" H
3" C
2" C
3" C
COVERED
CANOPY AREA
CONTROLLER
JANITOR
CLOSET
2 1/2" C
2 1/2" C
/4
C
/4
C
3" C
1 1/2" C
2" C 1" C
1 1/2" C
/2
H
LOCATION
OF ATTIC
ACCESS
IMB
P*12
P*4
P*4
P*4
P*4
P*4
P*4
P*3
P*3
P*3
P*2
P*2
P*2
P*2
P*2
P*2
P*2A
P*2A
P*2 P*2
P*3
HB/E
P*1A
P*1
P*1
P*1
P*3
P*1
P*1A
P*4
P*4
P*12
P*4
P*4P*3
HB
P*4
P*4
P*4
P*9 P*9
P*4
P*4
P*4
P*4
P*4
P*6P*12
P*2
P*2
P*2
P*2
P*2A
P*2A
P*2
P*2
P*3
P*3
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P102
DO
M
ES
TI
C P
LU
M B
IN
G
RE
N O
VA
TI
O N P
LA
N
S O U
TH
S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P102
1 DOMESTIC PLUMBING RENOVATION PLAN SOUTH
SOUTH
SIDE
1. WHERE PIPE SIZE IS NOT SHOWN REFER TO FIXTURE
SCHEDULE FOR CONNECTION SIZE.
2. PROVIDE HAMMER ARRESTOR AT EVERY FIXTURE. SEE
DETAIL.
3. ROUTE 1/2" COLD WATER TRAP PRIMER PIPING TO ALL
FLOOR DRAINS FROM COLD WATER LINE AT NEAREST
FIXTURE. SEE DETAILS.
PLUMBING KEYED NOTES
LOCATION OF DOMESTIC WATER RISER AND BACKFLOW PREVENTER
APPROVED FOR VERTICAL INSTALLATION. TAP LINE AFTER
BACKFLOW PREVENTER AND ROUTE TO ENHANCED VENDING AREA
FOR FUTURE RESTAURANT USE AS SHOWN.
LOCATE ELECTRIC WATER HEATER WH*2 UNDER COUNTER IN
CASEWORK. COORDINATE EXACT LOCATION WITH CONTRACTING
OFFICER PRIOR TO INSTALLATION.
ROUTE HOT WATER RETURN PIPING THROUGH HOT WATER
RECIRCULATION PUMP HWC*1 AS SHOWN AND CONNECT TO COLD
WATER LINE FEEDING WATER HEATER WH*1.
CAP DOMESTIC WATER LINE ABOVE CEILING FOR FUTURE
RESTAURANT USE.
OFFSET DOMESTIC COLD, HOT, AND HOT WATER RETURN PIPING UP
TO REMAIN ABOVE CEILING IN MAIN LOBBY AREA. SEE P101 FOR
CONTINUATION OF DOMESTIC PIPING.
SEE MECHANICAL DRAWINGS FOR NATURAL GAS PIPING SERVING
WATER HEATER WH*1.
ALL WORK IN THIS REGION, INCLUDING FIXTURE P*13, AND ALL
ASSOCIATED PIPING ON THIS PLAN, SHALL BE PART OF BID
ALTERNATE #3. HB/E AND ASSOCIATED PIPING SHALL REMAIN PART
OF BASE BID. REFER TO A000 FOR BID ALTERNATE NOTES.
(THIS SHEET ONLY)
PLUMBING GENERAL NOTES
6SCALE:P102
2 DOMESTIC PLUMBING RISER * 151/152
SCALE:P102
3 DOMESTIC PLUMBING RISER * 160/161
SCALE:P102
4 DOMESTIC PLUMBING RISER * 175*178
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
GARAGE
COMM.
WOMEN
MEN
READING ROOM
OIC OFFICE
SUPT. OFFICE
STORAGE
CONFERENCE
TRAINING
STO.
COPY AREA
ADMIN
LOUNGE LOBBY
PASSENGER
LOUNGE
BREAK ROOM
WOMENS
OPS NCOIC
OFFICE
VESTIBULE
DEPARTURE
GATE 2
SPEC. CAT
LOUNGE
UNISEX
SHOWER/
CHANGING
ROOM
BUSINESS
CENTER
COMM.
BAGGAGE
SCREENING
FUNDS
SUPR.
FLIGHT
CHECK#IN
COUNTER
DISPATCH
CENTRAL
LOBBY
1 2
A
B
C
H
3 4 5 5.2 7 7.1
W
W
4" W
W
P*4
P*4
P*7
TV ROOM
GAME ROOM
MECH./ELEC.
OPEN OFFICE
ADMIN LOBBY
CARTS
BAGGAGE
BUILD UP
DEPARTURE
GATE 1
2" W
P*8
FCO
FCO
3" VTR
V3
W
W
3" W
V
V
3"
VTR
/2
V
2" V2" V
3"
VTR
FD
FD
FD
P*1
P*1
P*1A
FD
2" V
P*8
P*4
P*4
W 2"
VTR
MENS
P*4
P*4 P*3
P*1 P*1
P*1 P*10
P*10
P*11
SEE CIVIL
DRAWINGS FOR
CONTINUATION
TYP
TYP
FD
FD
TYP
N
M
L.8
L
K
J
G
F
E
P*12
D
W
3" W
COVERED
CANOPY AREA
COMM.
CORRIDOR
CORRIDOR
SECURE GATE
CORRIDOR
W
W
W
2" W
4" W
3" W4" W
3" W
1 1/2" V
3" W
FD
TYP
P*12
P*4
P*4
P*3
P*1
P*1 P*10
P*1
P*10
FD
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P103
SA
N
IT
AR
Y
PL
U M B
IN
G
RE
N O
VA
TI
O N P
LA
N
N O
RT
H S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P103
1 WASTE & VENT PLUMBING RENOVATION PLAN NORTH
NORTH
SIDE
1. WHERE PIPE SIZE IS NOT SHOWN REFER TO FIXTURE SCHEDULE
FOR CONNECTION SIZE.
2. ALL WASTE PIPING TO BE INSTALLED UNDER SLAB UNLESS
OTHERWISE NOTED. COORDINATE LOCATION AND INVERT
ELEVATION OF ALL UNDERGROUND PIPING WITH STRUCTURAL.
3. VENT PIPING DRAWN DIAGRAMMATICALLY FOR CLARITY.
COORDINATE LOCATION OF ALL VENTS THROUGH ROOF WITH
OTHER TRADES.
PLUMBING KEYED NOTES
PROVIDE FLOOR DRAIN WITH TRAP PRIMER CONNECTION (TYP.
ALL FLOOR DRAINS), SEE DETAILS.
(THIS SHEET ONLY)
PLUMBING GENERAL NOTES
SCALE:P103
2 SANITARY PLUMBING RISER * 129/131
NOT TO SCALE
VESTIBULE
CARTS
ENHANCED
VENDING AREA
VESTIBULE
CAR RENTAL
PSC
FAMILY
LOUNGE
RESTROOM
CRIB ROOM
PLAY ROOM
ELEC.
ARRIVAL
WAITING
SPRINKLER
RISER ROOM
BAGGAGE
CLAIM
MEN
WOMEN
MECHANICAL
MEN
175WOMEN
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
CUSTOMS
SECURITY
SCREENING
SECURE GATE
CORRIDOR
DEPARTURE
GATE 2
MEN
WOMEN
DEPARTURE/ARRIVAL
GATE 3
BAGGAGE
BREAKDOWN
CENTRAL
LOBBY
WASTE LINE FOR
FUTURE GREASE TRAP,
SEE CIVIL DRAWINGS
FOR CONTINUATION
P*3
P*3
P*4
P*4
P*4
P*3
P*4
P*4
P*4
P*12
WH*1
P*1A P*1 P*3 P*3 P*4 P*4
P*1A P*1 P*1 P*1 P*4 P*4
P*12
4" W
4" W
W
3" W
P*12
P*4
P*4
COMM.
LOST & FOUND
CORRIDOR
FCO
WCO
P*4
P*4
P*4
P*4
P*7
P*3
4"
VTR
V
V
V
V
3" V3" V
4" W
4" VTR
2" V
3" W
FD
V
3" VTR
2" V
FD
FD
FD FD
FD
FD
FD
FD
FDFD
FD FD
FD
FD
FD3" W
SEE CIVIL
DRAWINGS FOR
CONTINUATION
P*4
P*2A
P*2
P*2
P*2A
P*2
P*2
P*2
P*2
P*2
P*2
P*2A
P*2 P*2
P*2
P*2
P*1A
2" VTR
3" W 2" V
P*13
1 1/2" V
1 1/4" W
V
2" W 1 1/2" W P*7
1 1/2" V
WH*2
P*3
P*3
P*2
P*2
P*2A
P*9 P*9
TYP
TYP
TYP
N
M
L.8
L
K
J
G
F
E
D
FCO
WCO
W
W
W
W
W
SEE P103 FOR
CONTINUATION
P*6
6" W6" W
COVERED
CANOPY AREA
CONTROLLER
JANITOR
CLOSET
3" V
3" W
6" W
4" W
2" W
4" W
4" W
W
V
3" W
2" V
LOCATION
OF ATTIC
ACCESS
P*12
P*4
P*4
P*4
P*4
P*4
P*4
P*3
P*3
P*3
P*2 P*2
P*2
P*2
P*2
P*2
P*2A
P*2A
P*2
P*2
P*3
VTR
WCO
FD
FD
FD
FD
P*4
P*4 P*4
P*9
P*9 P*4
P*4
P*4
P*4
P*4 P*6
P*12
P*2
P*2
P*2
P*2
P*2A
P*2A
P*2
P*2
P*3
P*3
TO VTR
FD
FD
FCO
FCO
FD
P*1A
P*1
P*1
P*1
P*3
P*1
P*1A
P*4
P*4
P*12
P*4
P*4 P*3
FD
FD
FD
VTR
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P104
SA
N
IT
AR
Y
PL
U M B
IN
G
RE
N O
VA
TI
O N P
LA
N
S O U
TH
S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P104
1 WASTE & VENT PLUMBING RENOVATION PLAN SOUTH
SOUTH
SIDE
1. WHERE PIPE SIZE IS NOT SHOWN REFER TO FIXTURE
SCHEDULE FOR CONNECTION SIZE.
2. ALL WASTE PIPING TO BE INSTALLED UNDER SLAB UNLESS
OTHERWISE NOTED. COORDINATE LOCATION AND INVERT
ELEVATION OF ALL UNDERGROUND PIPING WITH STRUCTURAL.
3. VENT PIPING DRAWN DIAGRAMMATICALLY FOR CLARITY.
COORDINATE LOCATION OF ALL VENTS THROUGH ROOF WITH
OTHER TRADES.
PLUMBING KEYED NOTES
4" WASTE LINE FOR POTENTIAL GREASE WASTE PRODUCED BY
FUTURE ENHANCED VENDING AREA OCCUPANT. CAP LINE ON
BOTH ENDS.
PROVIDE MANUFACTURER'S RECOMMENDED CONCENTRIC
VENT KIT WITH ROOF TERMINATION FOR NATURAL GAS FIRED
WATER HEATER WH*1. SEE DETAIL AND SCHEDULE FOR
ADDITIONAL INFORMATION.
PROVIDE FLOOR DRAIN WITH TRAP PRIMER CONNECTION (TYP.
ALL FLOOR DRAINS), SEE DETAILS.
ALL WORK IN THIS REGION, INCLUDING FIXTURE P*13 AND ALL
ASSOCIATED PIPING ON THIS PLAN, SHALL BE PART OF BID
ALTERNATE #3. IF BID ALTERNATE #3 IS NOT AWARDED THEN
P*13 SHALL NOT BE INSTALLED. REFER TO A000 FOR BID
ALTERNATE NOTES.
(THIS SHEET ONLY)
PLUMBING GENERAL NOTES
SCALE:P104
2 SANITARY PLUMBING RISER * 151/152
SCALE:P104
3 SANITARY PLUMBING RISER * 175*178
SCALE:P104
4 SANITARY PLUMBING RISER * 160/161
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
A
B
C
H
3 4 5 5.2 7 7.1
N
M
L.8
L
K
J
G
F
E
D
3" VTR
3" VTR
3" VTR
2" VTRMECHANICAL
HOODS
MECHANICAL
HOOD (TYP.)
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P105
PL
U M B
IN
G
RO
O F
PL
AN
N O
RT
H S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P105
1 ROOF PLUMBING RENOVATION PLAN NORTH
NORTH
SIDE
1. ALL VENTS THROUGH ROOF SHALL BE PAINTED. REFER
TO COLOR SCHEDULE
ON SHEET A600.
PLUMBING GENERAL NOTES
2" VTR
3" VTR
3" VTR
4" VTR
N
M
L.8
L
K
J
G
F
E
D
MECHANICAL
HOODS
MECHANICAL
HOOD (TYP.)
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
R
No.
K
TU
S
A
M K
YA. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
P106
PL
U M B
IN
G
RO
O F
PL
AN
S O U
TH
S
ID
E
DA
S
DA
S
M
AU
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"P106
1 ROOF PLUMBING RENOVATION PLAN SOUTH
SOUTH
SIDE
1. ALL VENTS THROUGH ROOF SHALL BE PAINTED. REFER
TO COLOR SCHEDULE ON SHEET A600.
PLUMBING GENERAL NOTES
PLUMBING KEYED NOTES
LOCATION OF ROOF PENETRATION FOR WATER HEATER
CONCENTRIC VENT KIT. SEE KEYNOTE ON P104. VENT
TERMINATION KIT MUST BE INSTALLED A MINIMUM OF 2' FROM
ROOF RIDGE.
(THIS SHEET ONLY)
MECHANICAL COMPONENT IMPORTANCE FACTOR (Ip) DESIGNATION
IBC#2006 /ASCE 7#05
SEISMIC AND WIND REQUIREMENTS FOR MECHANICAL SYSTEMS
COMPONENT IMPORTANCE FACTOR (Ip)
Ip = 1.0 Ip = 1.5
RESTRAIN IF TOTAL WEIGHT OF DUCTS
ON TRAPEZE > 10 LBS/FT 44
RESTRAIN IF TOTAL WEIGHT OF DUCTS
ON TRAPEZE > 10 LBS/FTMULTIPLE DUCTS ON TRAPEZE
5* 6 SQ.FT. AND LARGER
RESTRAIN IF ANY PIPE
ON TRAPEZE > 1"
RESTRAIN IF TOTAL WEIGHT OF PIPES
ON TRAPEZE > 10 LBS/FT
4 RESTRAIN ALL
RESTRAIN IF ANY PIPE
ON TRAPEZE > 3"
RESTRAIN IF TOTAL WEIGHT OF PIPES
ON TRAPEZE > 10 LBS/FT
RESTRAIN ALL
SUSPENDED PIPE ON TRAPEZE
SUSPENDED NON DUCTILE PIPING
(CAST IRON, PLASTIC, CERAMIC)
NOTES:
1. EQUIPMENT 20 LBS. OR LESS IS EXEMPT IF FLEXIBLE CONNECTIONS ARE PROVIDED BETWEEN THE COMPONENT AND
ASSOCIATED DUCTWORK, PIPING, AND CONDUIT.
2. RESTRAINTS ARE NOT REQUIRED IF THE COMPONENT WEIGHS 400 LBS. OR LESS, IS MOUNTED AT 4 FT. OR LESS ABOVE A FLOOR, AND HAS FLEXIBLE CONNECTIONS BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT.
3. FLEXIBLE CONNECTIONS REQUIRED FOR PIPE CONNECTIONS ONLY.
4. RESTRAINT IS NOT REQUIRED IF THE PIPING / DUCTWORK IS SUPPORTED BY HANGERS AND EACH HANGER IN THE PIPING RUN
IS 12 IN. OR LESS IN LENGTH FROM THE TOP OF THE PIPE TO THE SUPPORTING STRUCTURE. WHERE PIPES ARE SUPPORTED ON A TRAPEZE, THE TRAPEZE SHALL BE SUPPORTED BY HANGERS HAVING A LENGTH OF 12 IN. OR LESS. WHERE ROD HANGERS ARE USED, THEY SHALL BE EQUIPPED WITH SWIVELS, EYE NUTS OR OTHER DEVICES TO PREVENT BENDING IN THE ROD.
5. ALL DUCTWORK , REGARDLESS OF SIZE, DESIGNED TO CARRY TOXIC, HIGHLY TOXIC, OR EXPLOSIVE GASES OR USED FOR
SMOKE CONTROL MUST BE RESTRAINED.
6. COMPONENT CERTIFICATION MUST BE SUPPLIED BY THE EQUIPMENT MANUFACTURER AT TIME OF SUBMITTAL FOR REVIEW BY
ENGINEER OF RECORD.
A. PER SECTION…
This is the start of the file's text. The full file is on GovTribe.