Attachment__2_-_Drawings_dated_30_October_2013_-_Part_15.pdf

PDF 3 MB Posted

Attached to
Add/Repair Passenger Terminal, Bldg. 164
Solicitation number
FA4418-15-R-0009
Issued by

About this file

Attachment 2 - Drawings dated 30 October 2013 - Part 15 for Solicitation FA4418-16-R-0002 Add/Repair Passenger Terminal Bldg 164.

View the file

Other files

File Type Posted
Attachment__15_-_Spec_Section_01_32_16_00_20_dated_30_October_2013.pdf PDF
Attachment__14_-_Addendum__3_dated_9_February_2016.pdf PDF
FA4418-16-R-0002-0003_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__3.pdf PDF
FA4418-16-R-0002_-_Add_Repair_Passenger_Terminal _Bldg_164_-_Questions_and_Answers.pdf PDF
FA4418-16-R-0002-0001_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__2.pdf PDF
FA4418-16-R-0002_-_Pre-proposal_Site_Visit_Minutes_-_Passenger_Terminal.pdf PDF
Attachment__1_-_Pre-proposal_Site_Visit_Record_of_Attendance.pdf PDF
Attachment__2_-_Pre-proposal_Site_Visit_Presentation.pdf PDF
Attachment__11_-_Asbestos_ _Lead_Report_dated_10_October_2012.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_2.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_1.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_3.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_5.pdf PDF
FA4418-16-R-0002-0001_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__1.pdf PDF
Attachment__12_-_Passenger_Terminal_OS-SWPPP_dated_2_October_2013.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_4.pdf PDF
FA4418-16-R-0002_-_Pre-proposal_Conference_Transportation_Instructions.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_3.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_13.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_7.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_1.pdf PDF
Attachment__4_-_SID_Schedule_dated_30_October_2013.pdf PDF
Attachment__6_-_Green_Procurement_Form_dated_15_July_2015.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_2.pdf PDF
Attachment__3_-_FF E_Schedule_dated_30_October_2013.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_10.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_8.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_14.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_11.pdf PDF
Attachment__10_-_Addendum__2_dated_10_November_2015.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_6.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_12.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_2.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_3.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_9.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_4.pdf PDF
Attachment__5_-_Wage_Determination_dated_22_May_2015.pdf PDF
FA4418-16-R-0002_Add_Repair_Passenger_Terminal _Bldg_164.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_5.pdf PDF
Attachment__7_-_Submittal_Register_dated_14_March_2014.pdf PDF
Attachment__9_-_Spec_Section_01_32_17_00_20_NAS_dated_30_October_2013.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_1.pdf PDF
Attachment__8_-_Addendum__1_dated_17_September_2014.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE

TA

KE

A W

AY

C

ON

VE

YO

R

FUTURE

SCALE

X-RAY

SL

ID

ER

B

ED

C

ON

VE

YO

R

TURNING POST

(4" DIA. & 16" HIGH)

TAKEAWAY CONVEYOR

SCALE FEEDERSCALE CONVEYOR

BAGGAGE

BUILD UP

DISPATCH

SUPR.

FUNDS

GUARDRAIL

INCLINE CONV

Turning Post

Control Cab

CP

CP

CP

CP

CP

CP

Scale Conv

Feeder

12"+2/-0

CONVEYOR

c c CP c c CP c c CP c c CP c c CP c c CP

13+2/-0"

27'

12'-7"

6' 3'

12 +2/-0"

34"

27"

12 +2/-0"

B

EMERGENCY STOP

CONTROL PANEL

GUARDRAILS

DRAFT CURTAINS

CONTROL PANEL

CONTROL PANEL

EMERGENCY STOP

EMERGENCY STOP

GUARDRAILS

CONTROL CAB

DRAFT CURTAINS

BAGGAGE

CLAIM

BAGGAGE

BREAKDOWN

74'

SHROUD

INTERIOR WALL

12" + 1" (30" AT OVERHEAD DOOR OPENINGS)

FACE PANEL

CRESCENT PLATE

ANGLE

COVER

PLATE

SKIRT

SUPPORT

TOP OF CONVEYOR SHALL MATCH

TOP OF DOCK

15"

ANCILLARY ITEM #2

BAGGAGE HANDLING

EQUIPMENT (BHE)

1. INCLUDES, BUT NOT LIMITED TO:

a. CONVEYORS

b. SCALES

c. CONTROLS

d. INSTALLATION AND CONNECTION

e. TESTING

f. REFER TO SPEC SECTIONS 34 77 39.00 10 - INBOUND

BAGGAGE CONVEYOR, 34 77 39.00 20-OUTBOUND

BAGGAGE CONVEYOR AND 34 77 39 - BAGGAGE

CONVEYING EQUIPMENT FOR ADDITIONAL INFORMATION.

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND

COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT

AREN’T LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION,

ETC. AND SHALL BE COORDINATED AND INSTALLED AS PART OF

THE BASE BID SCOPE OF WORK.

4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE

GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF

WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT

REQUIREMENTS.

7. SECURITY SCANNING EQUIPMENT (SSE) TO BE PROVIDED AND

INSTALLED UNDER SEPERATE CONTRACT AND SHALL BE

COORDINATED BY GENERAL CONTRACTOR. REFER TO MEP

DRAWINGS FOR REQUIREMENTS, INCLUDING ALTERNATE

LOCATION, WHICH ARE PART OF THE BASE BID AND IN THE

GENERAL CONTRACTORS SCOPE OF WORK.

DRAFT CURTAINS

NOTE #7

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

AI

R

FO

RC

E

MA

TE

RI

EL

C

OM

MA

ND

MA

TE

RI

AL

H

AN

DL

IN

G

EN

GI

NE

ER

IN

G

DI

VI

SI

ON

A

FS

C/

LO

EE

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

FI

NA

L

SU

B

MI

TT

AL

ARCH30 E(30X42)

BHE01

B

AG

GA

GE

C

ON

VE

YO

R A I #2

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

N.T.S.1 BAGGAGE BUILD-UP CONVEYOR

N.T.S.2 BAGGAGE BREAKDOWN CONVEYOR

N.T.S.3 BAGGAGE BREAKDOWN SECTION B-B

DS K

DS KDS K

D S

DS

D S

D S

D S

D S

S

S S

S

K

1 2

A

B

C

H

3 4 5 5.2 7 7.1

A

A

A

B

B

C

A

B

A

GARAGE

COMM.

MEN

WOMEN

MECH./ELEC.

OPEN OFFICE

OIC OFFICE

SUPT. OFFICE

STORAGE

110READING ROOM

TV ROOM

112 GAME ROOM

PASSENGER

LOUNGE

CONFERENCE

117 LOUNGE LOBBY

ADMIN

COPY AREA

STO.

TRAINING

COMM.

BREAK ROOM

WOMENS

ALCOVE

BAGGAGE

BUILD UP

DISPATCH

FUNDS

SUPR.

BAGGAGE

SCREENING

ADMIN LOBBY

OPS NCOIC

OFFICE

CARTS

VESTIBULE

SECURE GATE

CORRIDOR

CENTRAL

LOBBY

CORRIDOR

DEPARTURE

GATE 2

150DEPARTURE

GATE 1

SPEC. CAT

LOUNGE

UNISEX

SHOWER/

CHANGING

ROOM

COMM.

BUSINESS

CENTER

N

M

L.8

L

K

J

G

F

E

D

SENTROL

SENTROL SENTROL

SENTROLU.S.A.

U.S.A.

U.S.A.

U.S.A.

8.00

SUSPENDED CEILING LEVEL

BMS DOOR SWITCH

W/ ARMORED CABLE

120VAC TO POWER SUPPLY

ALL CONDUIT TO BE MIN. 3/4" EMT

DOOR LOCK POWER SUPPLY

4x4 J-BOX

SECURE SIDE OF DOOR SECURE SIDE OF DOOR 3/4" CONDUIT IN DOOR FRAME

TO ELECTRIFIED CRASH BAR

(BOTH SIDES)

TRANSFER HINGE OR DOOR CORD

TO ELECTRIFIED CRASH BAR (BOTH

SIDES)

SINGLE GANG BOX FOR

IDS KEYPAD (HORIZONTALLY MOUNTED)

SCOPE OF WORK LEGEND

THE SCOPE OF WORK IS DEVIDED INTO TWO

SEPARATE DESIGNATIONS:

DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION

AND

DKFX: 11-1122 B FOR REPAIR

INDICATES WORK AS REQUIRED FOR - -

MINOR CONSTRUCTION (MC)

ALL OTHER WORK IS REPAIR

I

No.

A

TU

S

R B

E

AS. B

T

A

27238

RCAH OL INN

E E

D

R

P

F ESS IO O

E C

S N

E I L R

L A

G I

E N

N

N

S

O

0'

= 1'-0"

G

E W

B

A IR AS

I N 62 8

T H

IR

A

D

MAN

CO

M

MO

IT Y

B I L

SEAL AREA

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

OFSHEET

D A T E

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

ARCH30 E(30X42)DRAWING SIZE:

PROJECT NO.

OFSHEET

DE

PA

RT

M

EN

T O F

TH

E

AI

R

FO

RC

E

AI

R M O B

IL

IT

Y C O M M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

C H K

B Y

D R A W N

B Y

D S G N

B Y

S U P V

C H

E N G R

DKFX: 11-1122 A/B

G

LI

C K

/B O

E H

M

A S

S O

C

IA

TE

S

, I N

C

K

IN

G S

TR

E

E T, S U

IT

E

C H

A R

LE

S

TO

N

, S C

J O

IN

T

B A S E

C H A R L E S T O N

A B

C H A R

LE

S

TO

N S C

N

4' 8' 16'

1/8"

IDS01

IN

TR

U

SI

O N D

ET

EC

TI

O N P

LA

N

N O

RT

H S

ID

E

AI

M S

Au th or

B

SB

/3 0/

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

SCALE: 1/8" = 1'-0"IDS01

1 INTRUSION DETECTION PLAN

NORTH

SIDE

K

DOOR CONTACT

S

DS

TOUCH SCREEN

KEYPAD

PIEZO SPEAKER

DURESS SWITCH

INF

IEM

PS

INFRAGUARD PANEL

INPUT EXPANSION

MODULE

POWER SUPPLY

INTRUSION DETECTION SYSTEM LEGEND

SCALE: NOT TO SCALEIDS01

2 DOUBLE DOOR WITH ELECTRIFIED CRASH BAR

NOTES:

1. SEE SPECIFICATION SECTION SECTION 28 20 00.00 20

ELECTRONIC SECURITY SYSTEMS (ESS), COMMERCIAL FOR

ADDITIONAL INFORMATION.

2. GENERAL CONTRACTOR (GC) SHALL VERIFY AND COORDINATE

ALL REQUIREMENTS WITH IDS MANUFACTURER.

3. GC SHALL NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF

ANY CONFLICTS OR DISCREPANCIES.

4. REFER TO MEP FOR REQUIREMENTS WHICH ARE PART OF THE

BASE BID AND IN THE GC SCOPE OF WORK.

CAMERA

ANCILLARY ITEM #3 -

INTRUSION DETECTION

SYSTEM (IDS) NOTES:

1. INCLUDES, BUT NOT LIMITED TO:

a. CAMERAS

b. CONTACTS

c. KEYPADS

d. DURESS SWITCHES

e. ALL EQUIPMENT

f. INSTALLATION AND CONNECTION TO JBC MONITORING

SYTEMS

g. TESTING

h. REFER TO SPEC SECTION 28 20 00.00 20 - ELECTRONIC

SECURITY SYSTEMS FOR ADDITIONAL INFORMATION.

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND

COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT AREN’T

LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION, ETC. AND

SHALL BE COORDINATED AND INSTALLED AS PART OF THE BASE BID

SCOPE OF WORK.

4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE

GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT REQUIREMENTS.

CCTV CAMERA SCHEDULE

TYPE MANUF. MODEL DESCRIPTION QUAN.

A ARECONT AV2256 2MP CAMERA 7

B ARECONT AV3255 3MP CAMERA 11

C ARECONT AV5255 5MP CAMERA 4

D ARECONT AV8185DN 8MP CAMERA 1

E ARECONT AV12186DN 12MP 180 DEGREE

CAMERA

F ARECONT AV3255 3MP CAMERA 2

CAMERA F PART OF BID ALTERNATE #3

30'-2"

[9.21M]

27'-10"

[8.50M]

30'-2"

[9.21M]

27'-10"

[8.50M]

DS K K DS

D S

D S

DS

S S S S

DS

K K

K

8 9 9.3 9.7 10 11

D

A

B

B F F

B

B

B

B

C

B B C

A

C

E

E

CARTS

ENHANCED

VENDING AREA

VESTIBULE

FAMILY

LOUNGE

PLAY ROOM

ELEC.

ARRIVAL

WAITING

CRIB ROOM

RESTROOM

CORRIDOR

CAR RENTAL

PSC

WOMEN

MEN

MECHANICAL

BAGGAGE

CLAIM

BAGGAGE

BREAKDOWN

SPRINKLER

RISER ROOM

LOST & FOUND

MEN

COMM.

CUSTOMS

SHOWER/

CHANGING

ROOM

SHOWER/

CHANGING

ROOM

DEPARTURE/ARRIVAL

GATE 3

MEN

WOMEN

SECURITY

SCREENING

N

M

L.8

L

K

J

G

F

E

D

COVERED

CANOPY AREA

VESTIBULE

CENTRAL

LOBBY

SECURE GATE

CORRIDOR

DEPARTURE

GATE 2

IEMIFNPS

LOCATION

OF ATTIC

ACCESS

LIMITS OF BID ALTERNATE #3

CAMERAS ARE INCLUDED IN BID ALTERNATE #3

SCOPE OF WORK LEGEND

THE SCOPE OF WORK IS DEVIDED INTO TWO

SEPARATE DESIGNATIONS:

DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION

AND

DKFX: 11-1122 B FOR REPAIR

INDICATES WORK AS REQUIRED FOR - -

MINOR CONSTRUCTION (MC)

ALL OTHER WORK IS REPAIR

I

No.

A

TU

S

R B

E

AS. B

T

A

27238

RCAH OL INN

E E

D

R

P

F ESS IO O

E C

S N

E I L R

L A

G I

E N

N

N

S

O

0'

= 1'-0"

G

E W

B

A IR AS

I N 62 8

T H

IR

A

D

MAN

CO

M

MO

IT Y

B I L

SEAL AREA

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

OFSHEET

D A T E

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

ARCH30 E(30X42)DRAWING SIZE:

PROJECT NO.

OFSHEET

DE

PA

RT

M

EN

T O F

TH

E

AI

R

FO

RC

E

AI

R M O B

IL

IT

Y C O M M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

C H K

B Y

D R A W N

B Y

D S G N

B Y

S U P V

C H

E N G R

DKFX: 11-1122 A/B

G

LI

C K

/B O

E H

M

A S

S O

C

IA

TE

S

, I N

C

K

IN

G S

TR

E

E T, S U

IT

E

C H

A R

LE

S

TO

N

, S C

J O

IN

T

B A S E

C H A R L E S T O N

A B

C H A R

LE

S

TO

N S C

N

4' 8' 16'

1/8"

IDS02

IN

TR

U

SI

O N D

ET

EC

TI

O N P

LA

N

S O U

TH

S

ID

E

AI

M S

Au th or

B

SB

/3 0/

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

SCALE: 1/8" = 1'-0"IDS02

1 INTRUSION DETECTION PLAN

NORTH

SIDE

SOUTH

SIDE

K

DOOR CONTACT

S

DS

TOUCH SCREEN

KEYPAD

PIEZO SPEAKER

DURESS SWITCH

INF

IEM

PS

INFRAGUARD PANEL

INPUT EXPANSION MODULE

POWER SUPPLY

INTRUSION DETECTION SYSTEM LEGEND

ANCILLARY ITEM #3 -

INTRUSION DETECTION

SYSTEM (IDS) NOTES:

1. INCLUDES, BUT NOT LIMITED TO:

a. CAMERAS

b. CONTACTS

c. KEYPADS

d. DURESS SWITCHES

e. ALL EQUIPMENT

f. INSTALLATION AND CONNECTION TO JBC MONITORING

SYTEMS

g. TESTING

h. REFER TO SPEC SECTION 28 20 00.00 20 - ELECTRONIC

SECURITY SYSTEMS FOR ADDITIONAL INFORMATION.

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND

COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT AREN’T

LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION, ETC. AND

SHALL BE COORDINATED AND INSTALLED AS PART OF THE BASE BID

SCOPE OF WORK.

4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE

GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT REQUIREMENTS.

CAMERA

CCTV CAMERA SCHEDULE

TYPE MANUF. MODEL DESCRIPTION QUAN.

A ARECONT AV2256 2MP CAMERA 7

B ARECONT AV3255 3MP CAMERA 11

C ARECONT AV5255 5MP CAMERA 4

D ARECONT AV8185DN 8MP CAMERA 1

E ARECONT AV12186DN 12MP 180 DEGREE

CAMERA

F ARECONT AV3255 3MP CAMERA 2

CAMERA F PART OF BID ALTERNATE #3

1ST FLOOR

2ND FLOOR

CORRIDOR

RACK

IT ROOM

CABLE TRAY

CONDUIT

TYPICAL

CAMERA,

SEE NOTE 1

CABLE

TRAY

SLEEVE

CAT6 CABLE

ROOM

I

No.

A

TU

S

RB

E

AS. B

T

A

27238

RCAH OL INN

E E

D

R

P

F ESS IO O

E C

S N

E I L R

L A

G I

E N

N

N

S

O

G

E W

B

A IR AS

I N 62 8

T H

IR

A

D

MAN

CO

M

MO

IT Y

B I L

SEAL AREA

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

OFSHEET

D A T E

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

ARCH30 E(30X42)DRAWING SIZE:

PROJECT NO.

OFSHEET

DE

PA

RT

M

EN

T O F

TH

E

AI

R

FO

RC

E

AI

R M O B

IL

IT

Y C O M M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

C H K

B Y

D R A W N

B Y

D S G N

B Y

S U P V

C H

E N G R

DKFX: 11(1122 A/B

G

LI

C K

/B O

E H

M

A S

SO

C

IA

TE

S, IN

C

KI

N G

S

TR

EE

T, S U

IT

E

C H

A R

LE

ST

O N

, S C

J O

IN

T

B A S E

C H A R L E S T O N

A B

C H A R

LE

S

TO

N S C

IDS03

C C

TV

D

ET

AI

LS

A N D N O

TE

S

AI

DA

W

DA

W

B

SB

/3 0/

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

SCALE: NOT TO SCALEIDS03

1 CCTV SYSTEM DEVICE RISER

ANCILLARY ITEM #3 *

INTRUSION DETECTION

SYSTEM (IDS) NOTES:

1. INCLUDES, BUT NOT LIMITED TO:

a. CAMERAS

b. CONTACTS

c. KEYPADS

d. DURESS SWITCHES

e. ALL EQUIPMENT

f. INSTALLATION AND CONNECTION TO JBC MONITORING

SYTEMS

g. TESTING

h. REFER TO SPEC SECTION 28 20 00.00 20 * ELECTRONIC

SECURITY SYSTEMS FOR ADDITIONAL INFORMATION.

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND

COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT AREN’T

LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION, ETC. AND

SHALL BE COORDINATED AND INSTALLED AS PART OF THE BASE BID

SCOPE OF WORK.

4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE

GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT REQUIREMENTS.

NOTE 1: ELECTRICAL CONTRACTOR SHALL COORDINATE JUNCTION BOX LOCATION FOR EACH CAMERA

LOCATION WITH CAMERA MANUFACTURER TO OPTIMIZE VIEW RANGE.

REF.

1 2

A

B

C

H

3 4 5 5.2 7 7.1 8 9 9.3 9.7 10 11

FIDSFIDS

FIDS

FIDS

GARAGE

COMM.

MEN

WOMEN

MECH./ELEC.

OPEN OFFICE

OIC OFFICE

SUPT. OFFICE

STORAGE

READING ROOM

TV ROOM

GAME ROOM

PASSENGER

LOUNGE

CONFERENCE

117 LOUNGE LOBBY

ADMIN

COPY AREA

STO.

TRAINING

COMM.

BREAK ROOM

WOMENS

ALCOVE

BAGGAGE

BUILD UP

DISPATCH

FUNDS

SUPR.

BAGGAGE

SCREENING

ADMIN LOBBY

OPS NCOIC

OFFICE

CARTS

VESTIBULE

CARTS

ENHANCED

VENDING AREA

COVERED

CANOPY AREA

VESTIBULE

FAMILY

LOUNGE

PLAY ROOM

ELEC.

ARRIVAL

WAITING

CRIB ROOM

RESTROOM

CORRIDOR

CAR RENTAL

PSC

WOMEN

MEN

MECHANICAL

BAGGAGE

CLAIM

BAGGAGE

BREAKDOWN

SPRINKLER

RISER ROOM

LOST & FOUND

MEN

COMM.

CUSTOMS

SHOWER/

CHANGING

ROOM

SHOWER/

CHANGING

ROOM

DEPARTURE/ARRIVAL

GATE 3

MEN

WOMEN

SECURITY

SCREENING

SECURE GATE

CORRIDOR

CENTRAL

LOBBY

CORRIDOR

DEPARTURE

GATE 2

DEPARTURE

GATE 1

149SPEC. CAT

LOUNGE

UNISEX

SHOWER/

CHANGING

ROOM

COMM.

BUSINESS

CENTER

LEGEND:

FIDS FLIGHT INFORMATION

DISPLAY SYTEM

N

M

L.8

L

K

J

G

F

E

D

LOCATION

OF ATTIC

ACCESS

NOTES:

LIMITS OF BID ALTERNATE #3

TV

TV

TV TV

1. GENERAL CONTRACTOR (GC) SHALL VERIFY

AND COORDINATE ALL REQUIREMENTS WITH

AVS MANUFACTURER(S).

2. GC SHALL NOTIFY THE CONTRACTING

OFFICER IMMEDIATELY OF ANY CONFLICTS

OR DISCREPANCIES.

3. REFER TO MEP FOR REQUIREMENTS WHICH

ARE PART OF THE BASE BID AND IN THE GC

SCOPE OF WORK.

4. REFER TO IDS DRAWINGS.

SCOPE OF WORK LEGEND

THE SCOPE OF WORK IS DEVIDED INTO TWO

SEPARATE DESIGNATIONS:

DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION

AND

DKFX: 11*1122 B FOR REPAIR

INDICATES WORK AS REQUIRED FOR * *

MINOR CONSTRUCTION (MC)

ALL OTHER WORK IS REPAIR

I

No.

A

TU

S

RB

E

AS. B

T

A

27238

RCAH OL INN

E E

D

R

P

F ESS IO O

E C

S N

E I L R

L A

G I

E N

N

N

S

O

0'

= 1'*0"

G

E W

B

A IR AS

I N 62 8

T H

IR

A

D

MAN

CO

M

MO

IT Y

B I L

SEAL AREA

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

OFSHEET

D A T E

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

ARCH30 E(30X42)DRAWING SIZE:

PROJECT NO.

OFSHEET

DE

PA

RT

M

EN

T O F

TH

E

AI

R

FO

RC

E

AI

R M O B

IL

IT

Y C O M M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

C H K

B Y

D R A W N

B Y

D S G N

B Y

S U P V

C H

E N G R

DKFX: 11(1122 A/B

G

LI

C K

/B O

E H

M

A S

SO

C

IA

TE

S, IN

C

KI

N G

S

TR

EE

T, S U

IT

E

C H

A R

LE

ST

O N

, S C

J O

IN

T

B A S E

C H A R L E S T O N

A B

C H A R

LE

S

TO

N S C

N4' 8' 16'

1/8"

AVS01

AU

DI

O

V

IS

U

AL

S

YS

TE

M P

LA

N S

AI

DA

W

DA

W

B B

/3 0/

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

SCALE: 1/8" = 1'*0"AVS01

1 AUDIO VISUAL SYSTEMS PLAN 203

ANCILLARY ITEM #4 # AUDIO VISUAL SYSTEM

(AVS)

1. INCLUDES BUT NOT LIMITED TO:

a. CAMERAS

b. TV’S

c. SPEAKERS

d. MONITORING AND RECORDING EQUIPMENT

e. INSTALLATION AND CONNECTION

f. TESTING

g. REFER TO SPEC SECTION XX XX XX (IF NO

INFORMATION FOR THIS ANCILLARY ITEM IS IN THE

SPECS THEN ENGINEER TO DELETE THIS ENTIRE NOTE

g) FOR ADDITIONAL INFORMATION.

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR

INFORMATION AND COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE ELEMENTS

INCLUDE BUT AREN’T LIMITED TO CONDUIT, BOXES,

POWER, COMMUNICATION, ETC. AND SHALL BE

COORDINATED AND INSTALLED AS PART OF THE BASE

BID SCOPE OF WORK.

4. COORDINATION OF THIS WORK IS THE

RESPONSIBILITY OF THE GENERAL CONTRACTOR AND

PART OF THE BASE BID SCOPE OF WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY ITEM

NOTES.

6. REFER TO BID SHEDULE FOR PRICING BREAKOUT

REQUIREMENTS

REF.

WAP

WAP

WAPWAP

WAP

WAP

WAP

WAP

WAP

1 2

A

B

C

H

3 4 5 5.2 7 7.1

N

M

L.8

L

K

J

G

F

E

D

GENERAL NOTES:

1. PROVIDE WIRELESS ACCESS POINTS IN AN

ACCESSIBLE LOCATION ABOVE DROPPED CEILING,

BUT BELOW ATTIC SPACE. PROVIDE A PERMANENT

LABEL ON CEILING TILE DIRECTLY BELOW EQUIPMENT.

2. WIRELESS ACCESS POINT LOCATIONS SHOWN ARE

BASED ON A PARTICULAR SYSTEM AND WILL NOT BE

IDEAL FOR ALL SYSTEMS. CONTRACTOR SHALL

PROVIDE A WIRELESS STUDY TO DETERMINE ACTUAL

SPACING FOR PROPOSED EQUIPMENT TO PROVIDE

100% COVERAGE OF ENTIRE BUILDING.

3. PROVIDE RACK MOUNT TYPE POWER*OVER*

ETHERNET NETWORK SWITCHES IN EACH IT CLOSET

FOR FREE PUBLIC ACCESS NETWORK. GOVERNMENT

SHALL PROVIDE UTILITY SERVICE TO NETWORK

SWITCHES.

4. PROVIDE A CAT6E CABLE FROM EACH WIRELESS

ACCESS POINT TO NEAREST IT ROOM AND TERMINATE

TO DEDICATED SWITCH. CABLE SHALL BE ROUTED IN

J*HOOKS AROUND PERIMETER OF ROOMS TO CABLE*

TRAY.

5. ALL DATA CABLING FOR PUBLIC NETWORK SHALL BE

PURPLE IN COLOR.

6. CABLE*TRAY SHOWN ON THESE DRAWINGS ARE

INCLUDED IN A SEPARATE PACKAGE ARE FOR

REFERENCE ONLY. CONTRACTOR SHALL PROVIDE J*

HOOKS AS REQUIRED TO CABLE SUPPORTS FROM

DEVICES TO CABLE*TRAY.

7. GENERAL CONTRACTOR (QC) SHALL VERIFY AND

COORDINATE ALL REQUIREMENTS WITH WIFI

MANUFACTURER(S). GC SHALL NOTIFY THE

CONTRACTING OFFICER IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES. REFER TO MEP FOR

REQUIREMENTS WHICH ARE PART OF THE BASE BID

AND IN THE QC SCOPE OF WORK.

SYMBOL LEGEND:

WIRELESS ACCESS POINT:

POWER OVER ETHERNET TYPE

BY CISCO SYSTEMS OR PRIOR

APPROVED EQUAL

MANUFACTURER.

INDICATES EQUIPMENT OR

DEVICE SHALL BE LISTED FOR

EXTERIOR USE IN DAMP

LOCATIONS.

WAP

WP

WP

CONFERENCE

OPEN OFFICE

SUPT. OFFICE

OIC OFFICE

READING ROOM

STORAGE

MECH./ELEC.

OPEN OFFICE

TRAINING

COMM.

TV ROOM

GAME ROOM

PASSENGER

LOUNGE

LOUNGE LOBBY

ADMIN LOBBY

COVERED

CANOPY AREA

VESTIBULE

CENTRAL

LOBBY

DISPATCH

CORRIDOR

BUSINESS

CENTER

FUNDS

SUPR.

FLIGHT

CHECK#IN

COUNTER

DEPARTURE

GATE 1

DEPARTURE

GATE 2

SPEC. CAT

LOUNGE

UNISEX

SHOWER/

CHANGING

ROOM

COMM.

SECURE GATE

CORRIDOR

MENS

WOMENS

SHOWER

SHOWER

BREAK ROOM

ADMIN

COPY AREA

STO.

MEN

WOMEN

GARAGE

COMM.

SCOPE OF WORK LEGEND

THE SCOPE OF WORK IS DEVIDED INTO TWO

SEPARATE DESIGNATIONS:

DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION

AND

DKFX: 11*1122 B FOR REPAIR

INDICATES WORK AS REQUIRED FOR * *

MINOR CONSTRUCTION (MC)

ALL OTHER WORK IS REPAIR

I

No.

A

TU

S

RB

E

AS. B

T

A

27238

RCAH OL INN

E E

D

R

P

F ESS IO O

E C

S N

E I L R

L A

G I

E N

N

N

S

O

0'

= 1'*0"

G

E W

B

A IR AS

I N 62 8

T H

IR

A

D

MAN

CO

M

MO

IT Y

B I L

SEAL AREA

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

OFSHEET

D A T E

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

ARCH30 E(30X42)DRAWING SIZE:

PROJECT NO.

OFSHEET

DE

PA

RT

M

EN

T O F

TH

E

AI

R

FO

RC

E

AI

R M O B

IL

IT

Y C O M M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

C H K

B Y

D R A W N

B Y

D S G N

B Y

S U P V

C H

E N G R

DKFX: 11(1122 A/B

G

LI

C K

/B O

E H

M

A S

SO

C

IA

TE

S, IN

C

KI

N G

S

TR

EE

T, S U

IT

E

C H

A R

LE

ST

O N

, S C

J O

IN

T

B A S E

C H A R L E S T O N

A B

C H A R

LE

S

TO

N S C

N4' 8' 16'

1/8"

WF01

PU

B

LI

C W

IF

I

SY

ST

EM

N

O

RT

H P

LA

N A I #5

DA

W

Au th or

B

SB

/3 0/

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

SCALE: 1/8" = 1'*0"WF01

1 PUBLIC WIFI SYSTEMS PLAN 204

ANCILLARY ITEM #5 *

WIFI SYSTEM (WFS)

NORTH

SIDE

1. INCLUDES:

a. ACCESS CONTROL POINTS

b. ALL EQUIPMENT

c. INSTALLATION AND CONNECTION

d. TESTING

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR

INFORMATION AND COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE ELEMENTS

INCLUDE BUT AREN’T LIMITED TO CONDUIT, BOXES,

POWER, COMMUNICATION, ETC. AND SHALL BE

COORDINATED AND INSTALLED AS PART OF THE BASE BID

SCOPE OF WORK.

4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR AND PART OF THE BASE

BID SCOPE OF WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.

6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT

REQUIREMENTS.

WAP

WAP WAP

WAP

WAP

WAP

WAP

8 9 9.3 9.7 10 11

N

M

L.8

L

K

J

G

F

E

D

GENERAL NOTES:

1. PROVIDE WIRELESS ACCESS POINTS IN AN

ACCESSIBLE LOCATION ABOVE DROPPED CEILING,

BUT BELOW ATTIC SPACE. PROVIDE A PERMANENT

LABEL ON CEILING TILE DIRECTLY BELOW EQUIPMENT.

2. WIRELESS ACCESS POINT LOCATIONS SHOWN ARE

BASED ON A PARTICULAR SYSTEM AND WILL NOT BE

IDEAL FOR ALL SYSTEMS. CONTRACTOR SHALL

PROVIDE A WIRELESS STUDY TO DETERMINE ACTUAL

SPACING FOR PROPOSED EQUIPMENT TO PROVIDE

100% COVERAGE OF ENTIRE BUILDING.

3. PROVIDE RACK MOUNT TYPE POWER*OVER*

ETHERNET NETWORK SWITCHES IN EACH IT CLOSET

FOR FREE PUBLIC ACCESS NETWORK. GOVERNMENT

SHALL PROVIDE UTILITY SERVICE TO NETWORK

SWITCHES.

4. PROVIDE A CAT6E CABLE FROM EACH WIRELESS

ACCESS POINT TO NEAREST IT ROOM AND TERMINATE

TO DEDICATED SWITCH. CABLE SHALL BE ROUTED IN

J*HOOKS AROUND PERIMETER OF ROOMS TO CABLE*

TRAY.

5. ALL DATA CABLING FOR PUBLIC NETWORK SHALL BE

PURPLE IN COLOR.

6. CABLE*TRAY SHOWN ON THESE DRAWINGS ARE

INCLUDED IN A SEPARATE PACKAGE ARE FOR

REFERENCE ONLY. CONTRACTOR SHALL PROVIDE J*

HOOKS AS REQUIRED TO CABLE SUPPORTS FROM

DEVICES TO CABLE*TRAY.

7. GENERAL CONTRACTOR (QC) SHALL VERIFY AND

COORDINATE ALL REQUIREMENTS WITH WIFI

MANUFACTURER(S). GC SHALL NOTIFY THE

CONTRACTING OFFICER IMMEDIATELY OF ANY

CONFLICTS OR DISCREPANCIES. REFER TO MEP FOR

REQUIREMENTS WHICH ARE PART OF THE BASE BID

AND IN THE QC SCOPE OF WORK.

SYMBOL LEGEND:

WIRELESS ACCESS POINT:

POWER OVER ETHERNET TYPE

BY CISCO SYSTEMS OR PRIOR

APPROVED EQUAL

MANUFACTURER.

INDICATES EQUIPMENT OR

DEVICE SHALL BE LISTED FOR

EXTERIOR USE IN DAMP

LOCATIONS.

WAP

WP

WP

WP WP

LOCATION

OF ATTIC

ACCESS

DEPARTURE/ARRIVAL

GATE 3

MEN

WOMEN

SECURE GATE

CORRIDOR

DEPARTURE

GATE 2

CENTRAL

LOBBY

WOMEN

MEN

MECHANICAL

WOMEN

MEN

COMM.

CUSTOMS

SHOWER/

CHANGING

ROOM

SHOWER/

CHANGING

ROOM

LOST & FOUND

CORRIDOR

FAMILY

LOUNGE

RESTROOM

CRIB ROOM

ARRIVAL

WAITING

PLAY ROOM

ELEC.

VESTIBULE

COVERED

CANOPY AREA

ENHANCED

VENDING AREA

PSC

CAR RENTAL

BAGGAGE

CLAIM

156 BAGGAGE

BREAKDOWN

SPRINKLER

RISER ROOM

CONTROLLER

BAGGAGE

ACCESS

LIMITS OF BID ALTERNATE #3

SCOPE OF WORK LEGEND

THE SCOPE OF WORK IS DEVIDED INTO TWO

SEPARATE DESIGNATIONS:

DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION

AND

DKFX: 11*1122 B FOR REPAIR

INDICATES WORK AS REQUIRED FOR * *

MINOR CONSTRUCTION (MC)

ALL OTHER WORK IS REPAIR

I

No.

A

TU

S

RB

E

AS. B

T

A

27238

RCAH OL INN

E E

D

R

P

F ESS IO O

E C

S N

E I L R

L A

G I

E N

N

N

S

O

0'

= 1'*0"

0'

= 1'*0"

G

E W

B

A IR AS

I N 62 8

T H

IR

A

D

MAN

CO

M

MO

IT Y

B I L

SEAL AREA

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

OFSHEET

D A T E

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

ARCH30 E(30X42)DRAWING SIZE:

PROJECT NO.

OFSHEET

DE

PA

RT

M

EN

T O F

TH

E

AI

R

FO

RC

E

AI

R M O B

IL

IT

Y C O M M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

C H K

B Y

D R A W N

B Y

D S G N

B Y

S U P V

C H

E N G R

DKFX: 11(1122 A/B

G

LI

C K

/B O

E H

M

A S

SO

C

IA

TE

S, IN

C

KI

N G

S

TR

EE

T, S U

IT

E

C H

A R

LE

ST

O N

, S C

J O

IN

T

B A S E

C H A R L E S T O N

A B

C H A R

LE

S

TO

N S C

N4' 8' 16'

1/8"

5' 10' 20'

3/32"

WF02

PU

B

LI

C W

IF

I

SY

ST

EM

S O U

TH

P

LA

N A I #5

DA

W

Au th or

B

SB

/3 0/

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

AD

D/

RE

PA

IR

P

AS

SE

N

GE

R

TE

RM

IN

AL

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

B U

IL

DI

N G

SOUTH

SIDE

SCALE: 1/8" = 1'*0"WF02

1 PUBLIC WIFI SYSTEMS PLAN

ANCILLARY ITEM #5 *

WIFI SYSTEM (WFS)

1. INCLUDES:

a. ACCESS CONTROL POINTS

b. ALL EQUIPMENT

c. INSTALLATION AND CONNECTION

d. TESTING

2. LOCATIONS OF ELEMENTS ARE SHOWN FOR

INFORMATION AND COORDINATION PURPOSES.

3. UTILITIES AND SUPPORT FOR THESE

ELEMENTS INCLUDE BUT AREN’T LIMITED TO

CONDUIT, BOXES, POWER, COMMUNICATION,

ETC. AND SHALL BE COORDINATED AND

INSTALLED AS PART OF THE BASE BID SCOPE

OF WORK.

4. COORDINATION OF THIS WORK IS THE

RESPONSIBILITY OF THE GENERAL

CONTRACTOR AND PART OF THE BASE BID

SCOPE OF WORK.

5. REFER TO A000 FOR GENERAL ANCILLARY

ITEM NOTES.

6. REFER TO BID SCHEDULE FOR PRICING

BREAKOUT REQUIREMENTS.

03_100% CIVIL.pdf
C001_PRELIMINARY CONTRACTOR LAYDOWN AREA
C002_SITEWORK PROJECT BREAKDOWN PLAN
C100_DEMOLITION PLAN-BASE BID
C101_DEMOLITION PLAN-BID ALTERNATE
C200_SITE PLAN-BASE BID
C201_SITE PLAN-BID ALTERNATE
C300_GRADING & DRAINAGE PLAN-BASE BID
C301_GRADING & DRAINAGE PLAN-BID ALTERNATE
C310_DRAINAGE AREAS PLAN-BID ALTERNATE
C400_SITE UTILITY PLAN-BASE BID
C401_SITE UTILITY PLAN-BID ALTERNATE
C620_CIVIL DETAILS-SITE
C621_CIVIL DETAILS-SITE
C622_CIVIL DETAILS-SITE
C630_CIVIL DETAILS-STORM WATER
C631_CIVIL DETAILS-STORM WATER
C640_CIVIL DETAILS-WATER
C641_CIVIL DETAILS-SEWER
C700_EROSION CONTROL PLAN PHASE I-BASE BID
C701_EROSION CONTROL PLAN PHASE II-BASE BID
C710_EROSION CONTROL PLAN PASE I-BID ALTERNATE
C711_EROSION CONTROL PLAN PHASE II-BID ALTERNATE
C720_CIVIL DETAILS-EROSION CONTROL
C721_CIVIL DETAILS-EROSION CONTROL
04_100% LANDSCAPE.pdf
L100_OVERALL SITE PLAN BASE BID
L101_OVERALL SITE PLAN BID ALTERNATE
L102_ENLARGED SITE PLAN BASE BID
L103_ENLARGED SITE PLAN BID ALTERNATE
L200_LANDSCAPE PLAN BASE BID
L201_LANDSCAPE PLAN BID ALTERNATE
L500_LANDSCAPE DETAILS BASE BID AND BID ALTERNATE
12_100% INTERIOR.pdf
I101_059
I102_059
I201_059

File details come from the government source that posted it. Updated .