Attachment__2_-_Drawings_dated_30_October_2013_-_Part_15.pdf
PDF 3 MB Posted
- Attached to
- Add/Repair Passenger Terminal, Bldg. 164
- Solicitation number
- FA4418-15-R-0009
About this file
Attachment 2 - Drawings dated 30 October 2013 - Part 15 for Solicitation FA4418-16-R-0002 Add/Repair Passenger Terminal Bldg 164.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE
TA
KE
A W
AY
C
ON
VE
YO
R
FUTURE
SCALE
X-RAY
SL
ID
ER
B
ED
C
ON
VE
YO
R
TURNING POST
(4" DIA. & 16" HIGH)
TAKEAWAY CONVEYOR
SCALE FEEDERSCALE CONVEYOR
BAGGAGE
BUILD UP
DISPATCH
SUPR.
FUNDS
GUARDRAIL
INCLINE CONV
Turning Post
Control Cab
CP
CP
CP
CP
CP
CP
Scale Conv
Feeder
12"+2/-0
CONVEYOR
c c CP c c CP c c CP c c CP c c CP c c CP
13+2/-0"
27'
12'-7"
6' 3'
12 +2/-0"
34"
27"
12 +2/-0"
B
EMERGENCY STOP
CONTROL PANEL
GUARDRAILS
DRAFT CURTAINS
CONTROL PANEL
CONTROL PANEL
EMERGENCY STOP
EMERGENCY STOP
GUARDRAILS
CONTROL CAB
DRAFT CURTAINS
BAGGAGE
CLAIM
BAGGAGE
BREAKDOWN
74'
SHROUD
INTERIOR WALL
12" + 1" (30" AT OVERHEAD DOOR OPENINGS)
FACE PANEL
CRESCENT PLATE
ANGLE
COVER
PLATE
SKIRT
SUPPORT
TOP OF CONVEYOR SHALL MATCH
TOP OF DOCK
15"
ANCILLARY ITEM #2
BAGGAGE HANDLING
EQUIPMENT (BHE)
1. INCLUDES, BUT NOT LIMITED TO:
a. CONVEYORS
b. SCALES
c. CONTROLS
d. INSTALLATION AND CONNECTION
e. TESTING
f. REFER TO SPEC SECTIONS 34 77 39.00 10 - INBOUND
BAGGAGE CONVEYOR, 34 77 39.00 20-OUTBOUND
BAGGAGE CONVEYOR AND 34 77 39 - BAGGAGE
CONVEYING EQUIPMENT FOR ADDITIONAL INFORMATION.
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND
COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT
AREN’T LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION,
ETC. AND SHALL BE COORDINATED AND INSTALLED AS PART OF
THE BASE BID SCOPE OF WORK.
4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF
WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.
6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT
REQUIREMENTS.
7. SECURITY SCANNING EQUIPMENT (SSE) TO BE PROVIDED AND
INSTALLED UNDER SEPERATE CONTRACT AND SHALL BE
COORDINATED BY GENERAL CONTRACTOR. REFER TO MEP
DRAWINGS FOR REQUIREMENTS, INCLUDING ALTERNATE
LOCATION, WHICH ARE PART OF THE BASE BID AND IN THE
GENERAL CONTRACTORS SCOPE OF WORK.
DRAFT CURTAINS
NOTE #7
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
AI
R
FO
RC
E
MA
TE
RI
EL
C
OM
MA
ND
MA
TE
RI
AL
H
AN
DL
IN
G
EN
GI
NE
ER
IN
G
DI
VI
SI
ON
A
FS
C/
LO
EE
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
FI
NA
L
SU
B
MI
TT
AL
ARCH30 E(30X42)
BHE01
B
AG
GA
GE
C
ON
VE
YO
R A I #2
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
N.T.S.1 BAGGAGE BUILD-UP CONVEYOR
N.T.S.2 BAGGAGE BREAKDOWN CONVEYOR
N.T.S.3 BAGGAGE BREAKDOWN SECTION B-B
DS K
DS KDS K
D S
DS
D S
D S
D S
D S
S
S S
S
K
1 2
A
B
C
H
3 4 5 5.2 7 7.1
A
A
A
B
B
C
A
B
A
GARAGE
COMM.
MEN
WOMEN
MECH./ELEC.
OPEN OFFICE
OIC OFFICE
SUPT. OFFICE
STORAGE
110READING ROOM
TV ROOM
112 GAME ROOM
PASSENGER
LOUNGE
CONFERENCE
117 LOUNGE LOBBY
ADMIN
COPY AREA
STO.
TRAINING
COMM.
BREAK ROOM
WOMENS
ALCOVE
BAGGAGE
BUILD UP
DISPATCH
FUNDS
SUPR.
BAGGAGE
SCREENING
ADMIN LOBBY
OPS NCOIC
OFFICE
CARTS
VESTIBULE
SECURE GATE
CORRIDOR
CENTRAL
LOBBY
CORRIDOR
DEPARTURE
GATE 2
150DEPARTURE
GATE 1
SPEC. CAT
LOUNGE
UNISEX
SHOWER/
CHANGING
ROOM
COMM.
BUSINESS
CENTER
N
M
L.8
L
K
J
G
F
E
D
SENTROL
SENTROL SENTROL
SENTROLU.S.A.
U.S.A.
U.S.A.
U.S.A.
8.00
SUSPENDED CEILING LEVEL
BMS DOOR SWITCH
W/ ARMORED CABLE
120VAC TO POWER SUPPLY
ALL CONDUIT TO BE MIN. 3/4" EMT
DOOR LOCK POWER SUPPLY
4x4 J-BOX
SECURE SIDE OF DOOR SECURE SIDE OF DOOR 3/4" CONDUIT IN DOOR FRAME
TO ELECTRIFIED CRASH BAR
(BOTH SIDES)
TRANSFER HINGE OR DOOR CORD
TO ELECTRIFIED CRASH BAR (BOTH
SIDES)
SINGLE GANG BOX FOR
IDS KEYPAD (HORIZONTALLY MOUNTED)
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
I
No.
A
TU
S
R B
E
AS. B
T
A
27238
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
N
S
O
0'
= 1'-0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11-1122 A/B
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N
4' 8' 16'
1/8"
IDS01
IN
TR
U
SI
O N D
ET
EC
TI
O N P
LA
N
N O
RT
H S
ID
E
AI
M S
Au th or
B
SB
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'-0"IDS01
1 INTRUSION DETECTION PLAN
NORTH
SIDE
K
DOOR CONTACT
S
DS
TOUCH SCREEN
KEYPAD
PIEZO SPEAKER
DURESS SWITCH
INF
IEM
PS
INFRAGUARD PANEL
INPUT EXPANSION
MODULE
POWER SUPPLY
INTRUSION DETECTION SYSTEM LEGEND
SCALE: NOT TO SCALEIDS01
2 DOUBLE DOOR WITH ELECTRIFIED CRASH BAR
NOTES:
1. SEE SPECIFICATION SECTION SECTION 28 20 00.00 20
ELECTRONIC SECURITY SYSTEMS (ESS), COMMERCIAL FOR
ADDITIONAL INFORMATION.
2. GENERAL CONTRACTOR (GC) SHALL VERIFY AND COORDINATE
ALL REQUIREMENTS WITH IDS MANUFACTURER.
3. GC SHALL NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF
ANY CONFLICTS OR DISCREPANCIES.
4. REFER TO MEP FOR REQUIREMENTS WHICH ARE PART OF THE
BASE BID AND IN THE GC SCOPE OF WORK.
CAMERA
ANCILLARY ITEM #3 -
INTRUSION DETECTION
SYSTEM (IDS) NOTES:
1. INCLUDES, BUT NOT LIMITED TO:
a. CAMERAS
b. CONTACTS
c. KEYPADS
d. DURESS SWITCHES
e. ALL EQUIPMENT
f. INSTALLATION AND CONNECTION TO JBC MONITORING
SYTEMS
g. TESTING
h. REFER TO SPEC SECTION 28 20 00.00 20 - ELECTRONIC
SECURITY SYSTEMS FOR ADDITIONAL INFORMATION.
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND
COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT AREN’T
LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION, ETC. AND
SHALL BE COORDINATED AND INSTALLED AS PART OF THE BASE BID
SCOPE OF WORK.
4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.
6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT REQUIREMENTS.
CCTV CAMERA SCHEDULE
TYPE MANUF. MODEL DESCRIPTION QUAN.
A ARECONT AV2256 2MP CAMERA 7
B ARECONT AV3255 3MP CAMERA 11
C ARECONT AV5255 5MP CAMERA 4
D ARECONT AV8185DN 8MP CAMERA 1
E ARECONT AV12186DN 12MP 180 DEGREE
CAMERA
F ARECONT AV3255 3MP CAMERA 2
CAMERA F PART OF BID ALTERNATE #3
30'-2"
[9.21M]
27'-10"
[8.50M]
30'-2"
[9.21M]
27'-10"
[8.50M]
DS K K DS
D S
D S
DS
S S S S
DS
K K
K
8 9 9.3 9.7 10 11
D
A
B
B F F
B
B
B
B
C
B B C
A
C
E
E
CARTS
ENHANCED
VENDING AREA
VESTIBULE
FAMILY
LOUNGE
PLAY ROOM
ELEC.
ARRIVAL
WAITING
CRIB ROOM
RESTROOM
CORRIDOR
CAR RENTAL
PSC
WOMEN
MEN
MECHANICAL
BAGGAGE
CLAIM
BAGGAGE
BREAKDOWN
SPRINKLER
RISER ROOM
LOST & FOUND
MEN
COMM.
CUSTOMS
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
DEPARTURE/ARRIVAL
GATE 3
MEN
WOMEN
SECURITY
SCREENING
N
M
L.8
L
K
J
G
F
E
D
COVERED
CANOPY AREA
VESTIBULE
CENTRAL
LOBBY
SECURE GATE
CORRIDOR
DEPARTURE
GATE 2
IEMIFNPS
LOCATION
OF ATTIC
ACCESS
LIMITS OF BID ALTERNATE #3
CAMERAS ARE INCLUDED IN BID ALTERNATE #3
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11-1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11-1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR - -
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
I
No.
A
TU
S
R B
E
AS. B
T
A
27238
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
N
S
O
0'
= 1'-0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11-1122 A/B
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N
4' 8' 16'
1/8"
IDS02
IN
TR
U
SI
O N D
ET
EC
TI
O N P
LA
N
S O U
TH
S
ID
E
AI
M S
Au th or
B
SB
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'-0"IDS02
1 INTRUSION DETECTION PLAN
NORTH
SIDE
SOUTH
SIDE
K
DOOR CONTACT
S
DS
TOUCH SCREEN
KEYPAD
PIEZO SPEAKER
DURESS SWITCH
INF
IEM
PS
INFRAGUARD PANEL
INPUT EXPANSION MODULE
POWER SUPPLY
INTRUSION DETECTION SYSTEM LEGEND
ANCILLARY ITEM #3 -
INTRUSION DETECTION
SYSTEM (IDS) NOTES:
1. INCLUDES, BUT NOT LIMITED TO:
a. CAMERAS
b. CONTACTS
c. KEYPADS
d. DURESS SWITCHES
e. ALL EQUIPMENT
f. INSTALLATION AND CONNECTION TO JBC MONITORING
SYTEMS
g. TESTING
h. REFER TO SPEC SECTION 28 20 00.00 20 - ELECTRONIC
SECURITY SYSTEMS FOR ADDITIONAL INFORMATION.
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND
COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT AREN’T
LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION, ETC. AND
SHALL BE COORDINATED AND INSTALLED AS PART OF THE BASE BID
SCOPE OF WORK.
4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.
6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT REQUIREMENTS.
CAMERA
CCTV CAMERA SCHEDULE
TYPE MANUF. MODEL DESCRIPTION QUAN.
A ARECONT AV2256 2MP CAMERA 7
B ARECONT AV3255 3MP CAMERA 11
C ARECONT AV5255 5MP CAMERA 4
D ARECONT AV8185DN 8MP CAMERA 1
E ARECONT AV12186DN 12MP 180 DEGREE
CAMERA
F ARECONT AV3255 3MP CAMERA 2
CAMERA F PART OF BID ALTERNATE #3
1ST FLOOR
2ND FLOOR
CORRIDOR
RACK
IT ROOM
CABLE TRAY
CONDUIT
TYPICAL
CAMERA,
SEE NOTE 1
CABLE
TRAY
SLEEVE
CAT6 CABLE
ROOM
I
No.
A
TU
S
RB
E
AS. B
T
A
27238
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
N
S
O
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
IDS03
C C
TV
D
ET
AI
LS
A N D N O
TE
S
AI
DA
W
DA
W
B
SB
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: NOT TO SCALEIDS03
1 CCTV SYSTEM DEVICE RISER
ANCILLARY ITEM #3 *
INTRUSION DETECTION
SYSTEM (IDS) NOTES:
1. INCLUDES, BUT NOT LIMITED TO:
a. CAMERAS
b. CONTACTS
c. KEYPADS
d. DURESS SWITCHES
e. ALL EQUIPMENT
f. INSTALLATION AND CONNECTION TO JBC MONITORING
SYTEMS
g. TESTING
h. REFER TO SPEC SECTION 28 20 00.00 20 * ELECTRONIC
SECURITY SYSTEMS FOR ADDITIONAL INFORMATION.
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR INFORMATION AND
COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE ELEMENTS INCLUDE BUT AREN’T
LIMITED TO CONDUIT, BOXES, POWER, COMMUNICATION, ETC. AND
SHALL BE COORDINATED AND INSTALLED AS PART OF THE BASE BID
SCOPE OF WORK.
4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR AND PART OF THE BASE BID SCOPE OF WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.
6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT REQUIREMENTS.
NOTE 1: ELECTRICAL CONTRACTOR SHALL COORDINATE JUNCTION BOX LOCATION FOR EACH CAMERA
LOCATION WITH CAMERA MANUFACTURER TO OPTIMIZE VIEW RANGE.
REF.
1 2
A
B
C
H
3 4 5 5.2 7 7.1 8 9 9.3 9.7 10 11
FIDSFIDS
FIDS
FIDS
GARAGE
COMM.
MEN
WOMEN
MECH./ELEC.
OPEN OFFICE
OIC OFFICE
SUPT. OFFICE
STORAGE
READING ROOM
TV ROOM
GAME ROOM
PASSENGER
LOUNGE
CONFERENCE
117 LOUNGE LOBBY
ADMIN
COPY AREA
STO.
TRAINING
COMM.
BREAK ROOM
WOMENS
ALCOVE
BAGGAGE
BUILD UP
DISPATCH
FUNDS
SUPR.
BAGGAGE
SCREENING
ADMIN LOBBY
OPS NCOIC
OFFICE
CARTS
VESTIBULE
CARTS
ENHANCED
VENDING AREA
COVERED
CANOPY AREA
VESTIBULE
FAMILY
LOUNGE
PLAY ROOM
ELEC.
ARRIVAL
WAITING
CRIB ROOM
RESTROOM
CORRIDOR
CAR RENTAL
PSC
WOMEN
MEN
MECHANICAL
BAGGAGE
CLAIM
BAGGAGE
BREAKDOWN
SPRINKLER
RISER ROOM
LOST & FOUND
MEN
COMM.
CUSTOMS
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
DEPARTURE/ARRIVAL
GATE 3
MEN
WOMEN
SECURITY
SCREENING
SECURE GATE
CORRIDOR
CENTRAL
LOBBY
CORRIDOR
DEPARTURE
GATE 2
DEPARTURE
GATE 1
149SPEC. CAT
LOUNGE
UNISEX
SHOWER/
CHANGING
ROOM
COMM.
BUSINESS
CENTER
LEGEND:
FIDS FLIGHT INFORMATION
DISPLAY SYTEM
N
M
L.8
L
K
J
G
F
E
D
LOCATION
OF ATTIC
ACCESS
NOTES:
LIMITS OF BID ALTERNATE #3
TV
TV
TV TV
1. GENERAL CONTRACTOR (GC) SHALL VERIFY
AND COORDINATE ALL REQUIREMENTS WITH
AVS MANUFACTURER(S).
2. GC SHALL NOTIFY THE CONTRACTING
OFFICER IMMEDIATELY OF ANY CONFLICTS
OR DISCREPANCIES.
3. REFER TO MEP FOR REQUIREMENTS WHICH
ARE PART OF THE BASE BID AND IN THE GC
SCOPE OF WORK.
4. REFER TO IDS DRAWINGS.
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
I
No.
A
TU
S
RB
E
AS. B
T
A
27238
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
N
S
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
AVS01
AU
DI
O
V
IS
U
AL
S
YS
TE
M P
LA
N S
AI
DA
W
DA
W
B B
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"AVS01
1 AUDIO VISUAL SYSTEMS PLAN 203
ANCILLARY ITEM #4 # AUDIO VISUAL SYSTEM
(AVS)
1. INCLUDES BUT NOT LIMITED TO:
a. CAMERAS
b. TV’S
c. SPEAKERS
d. MONITORING AND RECORDING EQUIPMENT
e. INSTALLATION AND CONNECTION
f. TESTING
g. REFER TO SPEC SECTION XX XX XX (IF NO
INFORMATION FOR THIS ANCILLARY ITEM IS IN THE
SPECS THEN ENGINEER TO DELETE THIS ENTIRE NOTE
g) FOR ADDITIONAL INFORMATION.
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR
INFORMATION AND COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE ELEMENTS
INCLUDE BUT AREN’T LIMITED TO CONDUIT, BOXES,
POWER, COMMUNICATION, ETC. AND SHALL BE
COORDINATED AND INSTALLED AS PART OF THE BASE
BID SCOPE OF WORK.
4. COORDINATION OF THIS WORK IS THE
RESPONSIBILITY OF THE GENERAL CONTRACTOR AND
PART OF THE BASE BID SCOPE OF WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY ITEM
NOTES.
6. REFER TO BID SHEDULE FOR PRICING BREAKOUT
REQUIREMENTS
REF.
WAP
WAP
WAPWAP
WAP
WAP
WAP
WAP
WAP
1 2
A
B
C
H
3 4 5 5.2 7 7.1
N
M
L.8
L
K
J
G
F
E
D
GENERAL NOTES:
1. PROVIDE WIRELESS ACCESS POINTS IN AN
ACCESSIBLE LOCATION ABOVE DROPPED CEILING,
BUT BELOW ATTIC SPACE. PROVIDE A PERMANENT
LABEL ON CEILING TILE DIRECTLY BELOW EQUIPMENT.
2. WIRELESS ACCESS POINT LOCATIONS SHOWN ARE
BASED ON A PARTICULAR SYSTEM AND WILL NOT BE
IDEAL FOR ALL SYSTEMS. CONTRACTOR SHALL
PROVIDE A WIRELESS STUDY TO DETERMINE ACTUAL
SPACING FOR PROPOSED EQUIPMENT TO PROVIDE
100% COVERAGE OF ENTIRE BUILDING.
3. PROVIDE RACK MOUNT TYPE POWER*OVER*
ETHERNET NETWORK SWITCHES IN EACH IT CLOSET
FOR FREE PUBLIC ACCESS NETWORK. GOVERNMENT
SHALL PROVIDE UTILITY SERVICE TO NETWORK
SWITCHES.
4. PROVIDE A CAT6E CABLE FROM EACH WIRELESS
ACCESS POINT TO NEAREST IT ROOM AND TERMINATE
TO DEDICATED SWITCH. CABLE SHALL BE ROUTED IN
J*HOOKS AROUND PERIMETER OF ROOMS TO CABLE*
TRAY.
5. ALL DATA CABLING FOR PUBLIC NETWORK SHALL BE
PURPLE IN COLOR.
6. CABLE*TRAY SHOWN ON THESE DRAWINGS ARE
INCLUDED IN A SEPARATE PACKAGE ARE FOR
REFERENCE ONLY. CONTRACTOR SHALL PROVIDE J*
HOOKS AS REQUIRED TO CABLE SUPPORTS FROM
DEVICES TO CABLE*TRAY.
7. GENERAL CONTRACTOR (QC) SHALL VERIFY AND
COORDINATE ALL REQUIREMENTS WITH WIFI
MANUFACTURER(S). GC SHALL NOTIFY THE
CONTRACTING OFFICER IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES. REFER TO MEP FOR
REQUIREMENTS WHICH ARE PART OF THE BASE BID
AND IN THE QC SCOPE OF WORK.
SYMBOL LEGEND:
WIRELESS ACCESS POINT:
POWER OVER ETHERNET TYPE
BY CISCO SYSTEMS OR PRIOR
APPROVED EQUAL
MANUFACTURER.
INDICATES EQUIPMENT OR
DEVICE SHALL BE LISTED FOR
EXTERIOR USE IN DAMP
LOCATIONS.
WAP
WP
WP
CONFERENCE
OPEN OFFICE
SUPT. OFFICE
OIC OFFICE
READING ROOM
STORAGE
MECH./ELEC.
OPEN OFFICE
TRAINING
COMM.
TV ROOM
GAME ROOM
PASSENGER
LOUNGE
LOUNGE LOBBY
ADMIN LOBBY
COVERED
CANOPY AREA
VESTIBULE
CENTRAL
LOBBY
DISPATCH
CORRIDOR
BUSINESS
CENTER
FUNDS
SUPR.
FLIGHT
CHECK#IN
COUNTER
DEPARTURE
GATE 1
DEPARTURE
GATE 2
SPEC. CAT
LOUNGE
UNISEX
SHOWER/
CHANGING
ROOM
COMM.
SECURE GATE
CORRIDOR
MENS
WOMENS
SHOWER
SHOWER
BREAK ROOM
ADMIN
COPY AREA
STO.
MEN
WOMEN
GARAGE
COMM.
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
I
No.
A
TU
S
RB
E
AS. B
T
A
27238
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
N
S
O
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
WF01
PU
B
LI
C W
IF
I
SY
ST
EM
N
O
RT
H P
LA
N A I #5
DA
W
Au th or
B
SB
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SCALE: 1/8" = 1'*0"WF01
1 PUBLIC WIFI SYSTEMS PLAN 204
ANCILLARY ITEM #5 *
WIFI SYSTEM (WFS)
NORTH
SIDE
1. INCLUDES:
a. ACCESS CONTROL POINTS
b. ALL EQUIPMENT
c. INSTALLATION AND CONNECTION
d. TESTING
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR
INFORMATION AND COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE ELEMENTS
INCLUDE BUT AREN’T LIMITED TO CONDUIT, BOXES,
POWER, COMMUNICATION, ETC. AND SHALL BE
COORDINATED AND INSTALLED AS PART OF THE BASE BID
SCOPE OF WORK.
4. COORDINATION OF THIS WORK IS THE RESPONSIBILITY
OF THE GENERAL CONTRACTOR AND PART OF THE BASE
BID SCOPE OF WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY ITEM NOTES.
6. REFER TO BID SCHEDULE FOR PRICING BREAKOUT
REQUIREMENTS.
WAP
WAP WAP
WAP
WAP
WAP
WAP
8 9 9.3 9.7 10 11
N
M
L.8
L
K
J
G
F
E
D
GENERAL NOTES:
1. PROVIDE WIRELESS ACCESS POINTS IN AN
ACCESSIBLE LOCATION ABOVE DROPPED CEILING,
BUT BELOW ATTIC SPACE. PROVIDE A PERMANENT
LABEL ON CEILING TILE DIRECTLY BELOW EQUIPMENT.
2. WIRELESS ACCESS POINT LOCATIONS SHOWN ARE
BASED ON A PARTICULAR SYSTEM AND WILL NOT BE
IDEAL FOR ALL SYSTEMS. CONTRACTOR SHALL
PROVIDE A WIRELESS STUDY TO DETERMINE ACTUAL
SPACING FOR PROPOSED EQUIPMENT TO PROVIDE
100% COVERAGE OF ENTIRE BUILDING.
3. PROVIDE RACK MOUNT TYPE POWER*OVER*
ETHERNET NETWORK SWITCHES IN EACH IT CLOSET
FOR FREE PUBLIC ACCESS NETWORK. GOVERNMENT
SHALL PROVIDE UTILITY SERVICE TO NETWORK
SWITCHES.
4. PROVIDE A CAT6E CABLE FROM EACH WIRELESS
ACCESS POINT TO NEAREST IT ROOM AND TERMINATE
TO DEDICATED SWITCH. CABLE SHALL BE ROUTED IN
J*HOOKS AROUND PERIMETER OF ROOMS TO CABLE*
TRAY.
5. ALL DATA CABLING FOR PUBLIC NETWORK SHALL BE
PURPLE IN COLOR.
6. CABLE*TRAY SHOWN ON THESE DRAWINGS ARE
INCLUDED IN A SEPARATE PACKAGE ARE FOR
REFERENCE ONLY. CONTRACTOR SHALL PROVIDE J*
HOOKS AS REQUIRED TO CABLE SUPPORTS FROM
DEVICES TO CABLE*TRAY.
7. GENERAL CONTRACTOR (QC) SHALL VERIFY AND
COORDINATE ALL REQUIREMENTS WITH WIFI
MANUFACTURER(S). GC SHALL NOTIFY THE
CONTRACTING OFFICER IMMEDIATELY OF ANY
CONFLICTS OR DISCREPANCIES. REFER TO MEP FOR
REQUIREMENTS WHICH ARE PART OF THE BASE BID
AND IN THE QC SCOPE OF WORK.
SYMBOL LEGEND:
WIRELESS ACCESS POINT:
POWER OVER ETHERNET TYPE
BY CISCO SYSTEMS OR PRIOR
APPROVED EQUAL
MANUFACTURER.
INDICATES EQUIPMENT OR
DEVICE SHALL BE LISTED FOR
EXTERIOR USE IN DAMP
LOCATIONS.
WAP
WP
WP
WP WP
LOCATION
OF ATTIC
ACCESS
DEPARTURE/ARRIVAL
GATE 3
MEN
WOMEN
SECURE GATE
CORRIDOR
DEPARTURE
GATE 2
CENTRAL
LOBBY
WOMEN
MEN
MECHANICAL
WOMEN
MEN
COMM.
CUSTOMS
SHOWER/
CHANGING
ROOM
SHOWER/
CHANGING
ROOM
LOST & FOUND
CORRIDOR
FAMILY
LOUNGE
RESTROOM
CRIB ROOM
ARRIVAL
WAITING
PLAY ROOM
ELEC.
VESTIBULE
COVERED
CANOPY AREA
ENHANCED
VENDING AREA
PSC
CAR RENTAL
BAGGAGE
CLAIM
156 BAGGAGE
BREAKDOWN
SPRINKLER
RISER ROOM
CONTROLLER
BAGGAGE
ACCESS
LIMITS OF BID ALTERNATE #3
SCOPE OF WORK LEGEND
THE SCOPE OF WORK IS DEVIDED INTO TWO
SEPARATE DESIGNATIONS:
DKFX: 11*1122 A FOR ADD (MINOR CONSTRUCTION
AND
DKFX: 11*1122 B FOR REPAIR
INDICATES WORK AS REQUIRED FOR * *
MINOR CONSTRUCTION (MC)
ALL OTHER WORK IS REPAIR
I
No.
A
TU
S
RB
E
AS. B
T
A
27238
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
N
S
O
0'
= 1'*0"
0'
= 1'*0"
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
OFSHEET
D A T E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
ARCH30 E(30X42)DRAWING SIZE:
PROJECT NO.
OFSHEET
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
C H K
B Y
D R A W N
B Y
D S G N
B Y
S U P V
C H
E N G R
DKFX: 11(1122 A/B
G
LI
C K
/B O
E H
M
A S
SO
C
IA
TE
S, IN
C
KI
N G
S
TR
EE
T, S U
IT
E
C H
A R
LE
ST
O N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
A B
C H A R
LE
S
TO
N S C
N4' 8' 16'
1/8"
5' 10' 20'
3/32"
WF02
PU
B
LI
C W
IF
I
SY
ST
EM
S O U
TH
P
LA
N A I #5
DA
W
Au th or
B
SB
/3 0/
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
AD
D/
RE
PA
IR
P
AS
SE
N
GE
R
TE
RM
IN
AL
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
B U
IL
DI
N G
SOUTH
SIDE
SCALE: 1/8" = 1'*0"WF02
1 PUBLIC WIFI SYSTEMS PLAN
ANCILLARY ITEM #5 *
WIFI SYSTEM (WFS)
1. INCLUDES:
a. ACCESS CONTROL POINTS
b. ALL EQUIPMENT
c. INSTALLATION AND CONNECTION
d. TESTING
2. LOCATIONS OF ELEMENTS ARE SHOWN FOR
INFORMATION AND COORDINATION PURPOSES.
3. UTILITIES AND SUPPORT FOR THESE
ELEMENTS INCLUDE BUT AREN’T LIMITED TO
CONDUIT, BOXES, POWER, COMMUNICATION,
ETC. AND SHALL BE COORDINATED AND
INSTALLED AS PART OF THE BASE BID SCOPE
OF WORK.
4. COORDINATION OF THIS WORK IS THE
RESPONSIBILITY OF THE GENERAL
CONTRACTOR AND PART OF THE BASE BID
SCOPE OF WORK.
5. REFER TO A000 FOR GENERAL ANCILLARY
ITEM NOTES.
6. REFER TO BID SCHEDULE FOR PRICING
BREAKOUT REQUIREMENTS.
| 03_100% CIVIL.pdf |
| C001_PRELIMINARY CONTRACTOR LAYDOWN AREA |
| C002_SITEWORK PROJECT BREAKDOWN PLAN |
| C100_DEMOLITION PLAN-BASE BID |
| C101_DEMOLITION PLAN-BID ALTERNATE |
| C200_SITE PLAN-BASE BID |
| C201_SITE PLAN-BID ALTERNATE |
| C300_GRADING & DRAINAGE PLAN-BASE BID |
| C301_GRADING & DRAINAGE PLAN-BID ALTERNATE |
| C310_DRAINAGE AREAS PLAN-BID ALTERNATE |
| C400_SITE UTILITY PLAN-BASE BID |
| C401_SITE UTILITY PLAN-BID ALTERNATE |
| C620_CIVIL DETAILS-SITE |
| C621_CIVIL DETAILS-SITE |
| C622_CIVIL DETAILS-SITE |
| C630_CIVIL DETAILS-STORM WATER |
| C631_CIVIL DETAILS-STORM WATER |
| C640_CIVIL DETAILS-WATER |
| C641_CIVIL DETAILS-SEWER |
| C700_EROSION CONTROL PLAN PHASE I-BASE BID |
| C701_EROSION CONTROL PLAN PHASE II-BASE BID |
| C710_EROSION CONTROL PLAN PASE I-BID ALTERNATE |
| C711_EROSION CONTROL PLAN PHASE II-BID ALTERNATE |
| C720_CIVIL DETAILS-EROSION CONTROL |
| C721_CIVIL DETAILS-EROSION CONTROL |
| 04_100% LANDSCAPE.pdf |
| L100_OVERALL SITE PLAN BASE BID |
| L101_OVERALL SITE PLAN BID ALTERNATE |
| L102_ENLARGED SITE PLAN BASE BID |
| L103_ENLARGED SITE PLAN BID ALTERNATE |
| L200_LANDSCAPE PLAN BASE BID |
| L201_LANDSCAPE PLAN BID ALTERNATE |
| L500_LANDSCAPE DETAILS BASE BID AND BID ALTERNATE |
| 12_100% INTERIOR.pdf |
| I101_059 |
| I102_059 |
| I201_059 |
File details come from the government source that posted it. Updated .