Attachment__2_-_Drawings_dated_30_October_2013_-_Part_11.pdf

PDF 5 MB Posted

Attached to
Add/Repair Passenger Terminal, Bldg. 164
Solicitation number
FA4418-15-R-0009
Issued by

About this file

Attachment 2 - Drawings dated 30 October 2013 - Part 11 for Solicitation FA4418-16-R-0002 Add/Repair Passenger Terminal Bldg 164.

View the file

Other files

File Type Posted
Attachment__15_-_Spec_Section_01_32_16_00_20_dated_30_October_2013.pdf PDF
Attachment__14_-_Addendum__3_dated_9_February_2016.pdf PDF
FA4418-16-R-0002-0003_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__3.pdf PDF
FA4418-16-R-0002_-_Add_Repair_Passenger_Terminal _Bldg_164_-_Questions_and_Answers.pdf PDF
FA4418-16-R-0002-0001_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__2.pdf PDF
FA4418-16-R-0002_-_Pre-proposal_Site_Visit_Minutes_-_Passenger_Terminal.pdf PDF
Attachment__1_-_Pre-proposal_Site_Visit_Record_of_Attendance.pdf PDF
Attachment__2_-_Pre-proposal_Site_Visit_Presentation.pdf PDF
Attachment__11_-_Asbestos_ _Lead_Report_dated_10_October_2012.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_2.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_1.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_3.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_5.pdf PDF
FA4418-16-R-0002-0001_Add_Repair_Passenger_Terminal _Bldg_164_-_Amendment__1.pdf PDF
Attachment__12_-_Passenger_Terminal_OS-SWPPP_dated_2_October_2013.pdf PDF
Attachment__13_-_Temp_Facility_Specs_dated_12_June_2015_-_Part_4.pdf PDF
FA4418-16-R-0002_-_Pre-proposal_Conference_Transportation_Instructions.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_3.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_13.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_7.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_1.pdf PDF
Attachment__4_-_SID_Schedule_dated_30_October_2013.pdf PDF
Attachment__6_-_Green_Procurement_Form_dated_15_July_2015.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_2.pdf PDF
Attachment__3_-_FF E_Schedule_dated_30_October_2013.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_10.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_8.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_14.pdf PDF
Attachment__10_-_Addendum__2_dated_10_November_2015.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_6.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_12.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_2.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_3.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_9.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_4.pdf PDF
Attachment__5_-_Wage_Determination_dated_22_May_2015.pdf PDF
FA4418-16-R-0002_Add_Repair_Passenger_Terminal _Bldg_164.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_5.pdf PDF
Attachment__7_-_Submittal_Register_dated_14_March_2014.pdf PDF
Attachment__9_-_Spec_Section_01_32_17_00_20_NAS_dated_30_October_2013.pdf PDF
Attachment__1_-_Specifications_dated_30_October_2013_-_Part_1.pdf PDF
Attachment__2_-_Drawings_dated_30_October_2013_-_Part_15.pdf PDF
Attachment__8_-_Addendum__1_dated_17_September_2014.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F1

HOLLOW METAL

DO

OR

H

EI

GH

T

WIDTH

DOOR

NOTE: REFER TO A620 FOR STOREFRONT ELEVATIONS

F2

HOLLOW METAL

DO

OR

H

EI

GH

T

WIDTH

DOOR

FRAMED OPENING;

SMOOTH FRAME

(NO RABITS)

2" 2" 2" 2"

4" 4"

GLAZING TYPES

MARK

GL-1 BRONZE, BLAST RESISTANT, LOW E, LAMINATED,

INSULATED GLAZING UNITS

GL-2

GL-3

GL-4

GL-5

DESCRIPTION

REFER TO SPEC SECTION 08 81 00

SIZE

1 5/16"

GL-6

GL-7 MIRROR

9/16"

1/4" 1/4" 9/16"

9/16"

BRONZE, BLAST RESISTANT, LOW E, LAMINATED

GLAZING UNITS

TEMPERED GLASS

CLEAR GLASS

BRONZE, LOW E, LAMINATED, WINDBORNE DEBRIS

IMPACT RATED GLAZING UNITS

CLEAR, BLAST RESISTANT, LAMINATED GLAZING UNITS

D1

FLUSH

D2

FULL

VISION

D3

OVERHEAD

ROLLING

D4

SLIDING

(IR)

D5

SLIDING

(BR)

6" 6"

6" 1'-

0"

NOTE: REFER TO DOOR & FRAME SCHEDULE FOR GLAZING TYPE IN DOORS

DO

OR

H

EI

GH

T

DOOR WIDTH

DOOR WIDTH

DO

OR

H

EI

GH

T

DOOR WIDTH

DO

OR

H

EI

GH

T

14'-0" R.O. 14'-0" R.O.

7'- 8"

R .O

7'-

/2

" R .O

7'- 0"

EQ. DOOR WIDTH EQ.

7'-

1/ 2"

EQ. DOOR WIDTH EQ.

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A610

DO

OR

S C

HE

DU

LE

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

DOOR & FRAME SCHEDULE

TAG TYPE

DOOR FRAME HARDWARE

SET

DETAILS

NOTES TAGMATERIAL WIDTH HEIGHT THICKNESS FINISH GLAZING TYPE MATERIAL FINISH HEAD JAMB SILL 101A D4 ALUM 13' - 8 1/2" 7' - 0" 0' - 1 3/4" DK BRZ GL-5 INTEGRAL ALUM DK BRZ 01 5/A613 4/A613 10/A613 SLIDING, MOTION DETECTION, IR, E 101A 101B D5 ALUM 13' - 7" 7' - 0 1/2" 0' - 2 1/2" DK BRZ GL-6 INTEGRAL ALUM DK BRZ 01 3/A613 2/A613 1/A613 SLIDING, MOTION DETECTION, BR, E 101B 105 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A611 2/A611 1/A611 105 106 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 W/A620 ALUM DK BRZ 03 11/A624 5/A624 -- 106 107 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 P/A620 ALUM DK BRZ 03 11/A624 4/A624 & 5/A624 2/A624 107 108 D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 K/A620 ALUM DK BRZ 04 6/A622 8/A622 12/A622 BR 108 109 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A611 2/A611 -- 109 110 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 06 3/A612 6/A612 1/A611 110 111 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A612 6/A612 1/A611 111 112 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A611 2/A611 -- 112 114 D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 L/A620 ALUM DK BRZ 07 6/A622 9/A622 & 5/A622 12/A622 BR 114 115 D1 WD 5' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 08 3/A611 2/A611 -- 115 117 D1 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 09 3/A611 2/A611 1/A611 117 118 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A611 2/A611 -- 118 119 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A611 2/A611 -- 119 120 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 10 3/A611 2/A611 1/A611 120 121 D1 WD 2' - 6" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 11 3/A611 2/A611 -- 121 122 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 12 3/A611 2/A611 1/A611 122 123 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 12 3/A611 2/A611 1/A611 123

124A D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 13 6/A611 7/A611 8/A611 (SIM) 124A 124B D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 14 4/A611 10/A611 8/A611 BR 124B 124C D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 (SIM) 9/A613 -- NOTE 4, IR, E 124C 125 D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 15 8/A612 9/A612 8/A611 125 126 D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 40 5/A611 (SIM) 11/A611 (SIM) 9/A611 BR 126

127A D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 17 3/A611 2/A611 1/A611 127A 127B D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 17 3/A611 2/A611 -- 127B 127C D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 L/A620 ALUM DK BRZ 07 6/A622 8/A622 & 5/A622 12/A622 BR 127C 127D D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 18 7/A613 6/A613 1/A611 BR 127D 128 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A611 2/A611 1/A611 128 129 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 20 3/A611 2/A611 1/A611 129 130 D1 WD 2' - 6" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 130 131 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 20 3/A611 2/A611 1/A611 131 132 D1 WD 2' - 6" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 132 133 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 26 3/A611 2/A611 -- 133 134 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A612 5/A612 & 6/A612 1/A611 134 135 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A612 6/A612 -- 135 136 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A612 6/A612 -- 136

138A D3 STEEL 14' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4, IR, E 138A 138B D3 STEEL 14' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4, IR, E 138B 142 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 N/A620 ALUM DK BRZ 03 11/A624 5/A624 2/A624 142 143 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 10 3/A611 2/A611 1/A611 143

144A D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- R/A620 ALUM DK BRZ 23 11/A624 4/A624 2/A624 144A 144B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 25 6/A622 5/A622 12/A622 BR, E 144B 145 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 24 3/A611 2/A611 1/A611 145 146 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 24 3/A611 2/A611 1/A611 146 147 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- R/A620 ALUM DK BRZ 26 11/A624 4/A624 -- 147

149A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 X/A620 ALUM DK BRZ 27 11/A624 4/A624 2/A624 149A 149B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 149B 149C D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 149C 150A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 T/A620 ALUM DK BRZ 29 11/A624 5/A624 2/A624 150A 150B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 150B 150C D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 150C 153A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 X/A620 ALUM DK BRZ 29 11/A624 1/A623 -- 153A 153B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 153B 153C D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 153C 154 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- N/A620 ALUM DK BRZ 03 11/A624 5/A624 2/A624 154 155 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- R/A620 ALUM DK BRZ 10 11/A624 4/A624 2/A624 155

156A D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 156A 156B D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 M/A620 ALUM DK BRZ 30 11/A624 5/A624 -- 156B 156C D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 M/A620 ALUM DK BRZ 30 11/A624 5/A624 -- 156C 157 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 31 3/A611 2/A611 1/A611 157

158A D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4 & 14, IR, E 158A 158B D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4 & 14, IR, E 158B 158C D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4 & 14, IR, E 158C 159A D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 32 8/A612 9/A612 8/A611 BR 159A 159B D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 32 8/A612 9/A612 8/A611 BR 159B 162 D1 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 33 1/A612 4/A612 1/A611 162 163 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 26 2/A612 5/A612 1/A611 163 164 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 34 3/A611 2/A611 1/A611 164

165A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 Q/A620 ALUM DK BRZ 35 11/A624 5/A624 -- 165A 165B D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM DK BRZ 36 5/A611 11/A611 9/A611 BR 165B 167A -- -- 8' - 0" 7' - 0" 0' - 1 3/4" -- -- F2 HM PT-14 -- 12/A611 13/A611 1/A611 (SIM) FRAMED OPENING 167A 167B D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 K/A620 ALUM DK BRZ 37 6/A622 8/A622 12/A622 BR 167B 168 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 12 3/A612 6/A612 1/A611 168 169 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 38 3/A612 6/A612 -- 169 170 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 P/A620 ALUM DK BRZ 39 11/A624 4/A624 & 5/A624 -- 170 171 D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 16 5/A611 11/A611 9/A611 BR 171

172A D4 ALUM 13' - 8 1/2" 7' - 0" 0' - 1 3/4" DK BRZ GL-5 INTEGRAL ALUM DK BRZ 01 5/A613 4/A613 10/A613 SLIDING, MOTION DETECTION, IR, E 172A 172B D5 ALUM 13' - 7" 7' - 0 1/2" 0' - 2 1/2" DK BRZ GL-6 INTEGRAL ALUM DK BRZ 01 3/A613 2/A613 1/A613 SLIDING, MOTION DETECTION, BR, E 172B 173 -- -- 8' - 0" 7' - 0" 0' - 1 3/4" -- -- F2 HM PT-14 -- 12/A611 13/A611 1/A611 (SIM) FRAMED OPENING 173 176 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 176 178 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 178 180 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 11 3/A611 2/A611 1/A611 180

SCALE: 1/4" = 1'-0"

DOOR FRAME ELEVATIONS

DOOR SCHEDULE NOTES

1 REFER TO EXTERIOR FINISH SCHEDULE, A201 FOR BASIS OF DESIGN FOR BLAST RESISTANT DOOR

ASSEMBLIES AND STOREFRONT SYSTEMS.

2 REFER TO DOOR ELEVATIONS FOR GLAZING LOCATIONS

3 DK BRZ IS ANODIZED DARK BRONZE FINISH, AA-M10 C22 A34

4 IMPACT RATED OH DOOR. MIN. 20 GA. SLATS; REFER TO SPEC. SECTION 08 33 23 AND ELECTRICAL 5 REFER TO FINISH SCHEDULE A600 FOR PAINT COLORS, PAINT NOTES, AND SPEC. SECTION 09 90 00 PAINTS

AND COATINGS.

6 REFER TO A620 FOR STOREFRONT ELEVATIONS, GLAZING TYPES AND LOCATIONS.

7 REFER TO SPEC SECTION 08 71 00 FOR HARDWARE REQUIREMENTS.

8 BR INDICATES BLAST RESISTANT - ALL EXTERIOR DOORS ARE TO BE BLAST RESISTANT AS REQUIRED BY

UFC 4-010-01, DoD MINIMUM ANTI TERRORISM STANDARDS FOR BUILDINGS, LATEST EDITION.

9 IR INDICATES IMPACT RESISTANT - DOORS NOT REQUIRED TO BE BLAST RESISTANT PER UFC 4-010-01, DoD

MINIMUM ANTI TERRORISM STANDARDS FOR BUILDINGS, LATEST EDITION ARE REQUIRED TO BE IMPACT RESISTANT IN ACCORDANCE WITH 2009 IBC DESIGN PRESSURE RATINGS AND LARGE MISSLE TESTS

10 BASIS OF DESIGN FOR AUTOMATIC SLIDING DOOR IS STANLEY, DURA-SHEILD HIGH SECURITY SERIES, BALLISTIC / BLAST RESISTANT AUTOMATIC SLIDING DOOR SYSTEMS, DUAL MOTOR DRIVE, WITH SU-100

MOTIOIN SENSOR, DARK BRONZE FINISH

11 BASIS OF DESIGN FOR INTERIOR STOREFRONT IS EFCO SERIES 401, COLOR - DK BRZ, FINISH - AA-M10 C22 A34

12 REFER TO SPECIFICATION SECTION 08 39 54 - BLAST RESISTANT DOORS, REFER TO SPECIFICATION SECTION 08 42 29.43 - IMPACT RATED SLIDING AUTOMATIC ENTRANCES, REFER TO SPECIFICATION

SECTION 08 42 29.53 - BLAST RESISTANT SLIDING AUTOMATIC ENTRANCES

13 E INDICATES ELECTRICAL CONNECTION IS REQUIRED. REFER TO ELECTRICAL.

14 ALL SURFACES OF STRUCTURAL STEEL PLATES, CHANNELS, COLUMNS AND ANGLES USED TO RE-INFORCE

OPENINGS FOR AT-FP SHALL BE FINISHED WITH COATING 1 (C1); REFER TO A201 EXTERIOR MATERIAL &

COLOR LEGEND, AND SPECIFICATION SECTION 09 97 13.00 40 STEEL COATINGS.

15 SEAL ALL SURFACES OF DOORS WITH PAINT OR STAIN, INCLUDING EDGES.

16 DOORS INDICATED TO BE STAINED TO BE IN ACCORDANCE WITH 2.2.8.6 ON A600

17 EXPOSED OR CONCEALED STEEL PLATES, ANGLES OR TUBES TO BE C1; REFER TO A201 & SPECIFICATION

SECTION 09 97 13.00 40 STEEL COATINGS.

SCALE: 1/4" = 1'-0"

DOOR ELEVATIONS

(2) 3'-0"

(2) 2'-6"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-0"

(2) 3'-6 1/2"

(2) 3'-7 1/8"

(2) 3'-6 1/2"

(2) 3'-7 1/8"

HOLLOW METAL DOOR FRAME;

REFER TO DOOR SCHEDULE

DOOR; REFER TO

DOOR SCHEDULE

TRANSITION STRIP (IF REQUIRED);

REFER TO DOOR SCHEDULE, FLOOR

FINISH PLAN, DETAILS & NOTES

EXISTING SLAB; REFER TO

STRUCTURAL FLOOR FINISH; REFER

FINISH SCHEDULE

5 3/4"

SEALANT; BOTH

SIDES , TYP.

DOOR; REFER TO

DOOR SCHEDULE

METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

GYPSUM BOARD

HOLLOW METAL DOOR FRAME;

REFER TO DOOR SCHEDULE

DOUBLE STUD AT JAMB;

EACH SIDE, TYP.

SOUND BATTS; REFER TO

PLAN(S) AND WALL TYPES

FOR LOCATION(S)

5 3/4"

2"

SOUND BATTS; REFER

TO PLAN(S) & WALL

TYPES FOR LOCATION(S)

SEALANT; BOTH

SIDES, TYP.

DOOR; REFER TO

DOOR SCHEDULE

METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

GYPSUM BOARD; ABUT

DOOR FRAME

HOLLOW METAL DOOR

FRAME; REFER TO

DOOR SCHEDULE

METAL STUD HEADER;

REFER TO STRUCTURAL

5 3/4"

4"

NEW/EXISTING BRICK

VENEER/STUD WALL; REFER TO

FLOOR PLAN AND WALL TYPES

AIR SPACE

STEEL LINTEL; REFER TO

STRUCTURAL

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

BACKER-ROD & SEALANT

DOOR; REFER TO

DOOR SCHEDULE

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT AND ATTACH

TO STEEL PLATE2" 5 3/4"

CMU LINTEL BLOCK;

REFER TO STRUCTURAL

FLUID APPLIED VAPOR BARRIER AT NEW CMU

WALL LOCATIONS. APPLY TO CONCEALED

EDGE OF CMU PRIOR TO INSTALLATION OF

STEEL PLATE AND/OR BRICK. REFER TO

EXTERIOR FINISH SCHEDULE.

SEALANT

STEEL TUBE; FINISH TO BE

C1; REFER TO EXTERIOR

MATERIAL & COLOR

SCHEDULE; REFER TO

STRUCTURAL

BOLT STEEL PLATE TO CMU;

REFER TO STRUCTURAL

STEEL PLATE; PAINT

EXPOSED SURFACES,

REFER TO STRUCTURAL

LAP FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

HEAD FLASHING, TYPE F; REFER TO

A620 FOR FLASHING TYPES SELF-ADHERING BITUTHANE

FLASHING WRAP AT OPENING;

REFER TO A625 FOR SEQUENCE

NEW/EXISTING BRICK VENEER/CMU

STUD WALL; REFER TO FLOOR

PLAN AND WALL TYPES

AIR SPACE

STEEL LINTEL; REFER TO

STRUCTURAL

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

BACKER-ROD & SEALANT

DOOR; REFER TO

DOOR SCHEDULE

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT AND ATTACH

TO STEEL PLATE

2 1/8" 8 5/8"

CMU LINTEL BLOCK(S);

REFER TO STRUCTURALFLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS. APPLY

TO CONCEALED EDGE OF CMU PRIOR

TO INSTALLATION OF STEEL PLATE

AND/OR BRICK. REFER TO EXTERIOR

FINISH SCHEDULE.

SEALANT

BOLT STEEL PLATE TO CMU;

REFER TO STRUCTURAL

LAP COAT OF FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

SELF-ADHERING BITUTHANE

FLASHING WRAP AT OPENING;

REFER TO A625 FOR SEQUENCE

STEEL TUBE; REFER TO

STRUCTURAL

BATT INSULATION

GYPSUM BOARD

CORNER BEAD

GYPSUM BOARD; ATTACH TO

TRACK/CHANNEL, ADHERE

TO STEEL PLATE AND

ABUT DOOR FRAME

STEEL PLATE; ATTACH TO

TUBE STEEL, REFER TO

STRUCTURAL

METAL CHANNEL

METAL STUD HEADER;

REFER TO STRUCTURAL

METAL TRACK; TRIM AT

TUBE STEEL

SEALANT; TYP.

DOOR, REFER TO

DOOR SCHEDULE

CMU/METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

METAL STUD HEADER;

REFER TO STRUCTURAL

GYPSUM BOARD

HOLLOW METAL DOOR

FRAME; FILL WITH GROUT,

REFER TO DOOR SCHEDULE

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

CORNER BEAD

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL) SOUND BATTS; REFER

TO PLAN(S) AND WALL

TYPES FOR LOCATION(S)

SEALANT; TYP.

5 3/4"

AIR SPACE

FLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS; APPLY

TO CONCEALED EDGE OF CMU PRIOR

TO INSTALLATION OF STEEL PLATE

AND/OR BRICK, REFER TO EXTERIOR

FINISH SCHEDULE

BACKER-ROD & SEALANT

DOOR; REFER TO

DOOR SCHEDULE

STEEL TUBE; FINISH

TO BE C1; REFER TO

EXTERIOR MATERIAL

& COLOR SCHEDULE;

REFER TO

STRUCTURAL

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT AND ATTACH

TO STEEL PLATE.

BRICK/CMU WALL;

REFER TO FLOOR

PLAN AND WALL TYPESREFER TO STRUCTURAL FOR

CMU REINFORCEMENT SIZE,

QUANTITY AND LOCATION(S)

STEEL PLATE; ATTACH TO

TUBE STEEL, PAINT, REFER

TO STRUCTURAL

BOLT STEEL PLATE TO CMU;

REFER TO STRUCTURAL

SEALANT

SELF-ADHERING BITUTHANE

FLASHING WRAP; REFER TO

A625 FOR SEQUENCE

2" 5 3/4"

AIR SPACE

FLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS; APPLY

TO CONCEALED EDGE OF CMU

PRIOR TO INSTALLATION OF STEEL

PLATE AND/OR BRICK, REFER TO

EXTERIOR FINISH SCHEDULE

BACKER-ROD &

SEALANT; TYP.

DOOR; REFER TO

DOOR SCHEDULE

STEEL TUBE; REFER TO

STRUCTURAL

HOLLOW METAL DOOR FRAME;

CONCEAL ANCHOR BOLT, FILL

WITH GROUT AND ATTACH TO

STEEL PLATE.

BATT INSULATION

BRICK/CMU/METAL STUD

WALL; REFER TO FLOOR

PLAN AND WALL TYPES

GYPSUM BOARD

CORNER BEAD

REFER TO STRUCTURAL

FOR CMU REINFORCEMENT

SIZE AND LOCATION(S)

GYPSUM BOARD; ATTACH TO

CHANNEL, ADHERE TO STEEL

PLATE AND ABUT FRAME

STEEL PLATE; ATTACH TO

TUBE STEEL, REFER TO

STRUCTURAL

METAL TRACK; ATTACH TO

SLAB, CONTINUE TO CORNER

METAL CHANNEL

BOLT STEEL PLATE TO CMU;

REFER TO STRUCTURAL

SEALANT; TYP.

SELF-ADHERING BITUTHANE

FLASHING WRAP AT

OPENING; REFER TO A625

FOR SEQUENCE

2" 8 3/4"

SEALANT; TYP.

DOOR; REFER TO

DOOR SCHEDULE

CMU/METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

SOUND BATTS; REFER TO

PLAN AND WALL TYPES

FOR LOCATIONS

DOUBLE STUDS AT JAMB;

EACH SIDE TYP.

GYPSUM BOARD

HOLLOW METAL DOOR

FRAME; FILL WITH GROUT,

REFER TO DOOR SCHEDULE

REFER TO STRUCTURAL FOR

CMU REINFORCEMENT SIZE,

QUANTITY AND LOCATION(S)

CORNER BEAD

5 3/4"

SEALANT, TYP.

HOLLOW METAL DOOR FRAME;

REFER TO DOOR SCHEDULE

DOOR; REFER TO

DOOR SCHEDULE

EXPANSION JOINT;

REFER TO STRUCTURAL

CONCRETE SIDEWALK;

REFER TO CIVIL

THRESHOLD; REFER TO

DOOR SCHEDULE AND

HARDWARE SPEC SECTION

08 71 00 FOR TYPE & SIZE

EXISTING SLAB; REFER TO

STRUCTURAL

2" 5 3/4"

HOLLOW METAL DOOR FRAME;

REFER TO DOOR SCHEDULE

DOOR; REFER TO

DOOR SCHEDULE

EXPANSION JOINT;

REFER TO STRUCTURAL

CONCRETE SIDEWALK;

REFER TO CIVIL

THRESHOLD; REFER TO

DOOR SCHEDULE AND

HARDWARE SPEC SECTION

08 71 00 FOR TYPE & SIZE

EXISTING SLAB; REFER TO

STRUCTURAL

2" 8 3/4" SOUND BATTS; REFER

TO PLAN(S) & WALL

TYPES FOR LOCATION(S)

SEALANT; BOTH

SIDES, TYP.

METAL STUD WALL;

REFER TO FLOOR

PLAN AND WALL TYPES

GYPSUM BOARD; ABUT

DOOR FRAME

HOLLOW METAL

CASING FRAME; REFER

TO DOOR SCHEDULE

METAL STUD HEADER;

REFER TO STRUCTURAL

4"

5 3/4"

SEALANT; BOTH

SIDES , TYP.

METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

GYPSUM BOARD

HOLLOW METAL DOOR FRAME;

REFER TO DOOR SCHEDULE

DOUBLE STUD AT JAMB;

EACH SIDE, TYP.

SOUND BATTS; REFER TO

PLAN(S) AND WALL TYPES

FOR LOCATION(S)

2"

5 3/4"

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A611

DO

OR

D

ET

AI

LS

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 3" = 1'-0"1 INTERIOR DOOR TRANSITION

SCALE: 3" = 1'-0"2 INTERIOR DOOR JAMB

SCALE: 3" = 1'-0"3 INTERIOR DOOR HEAD

SCALE: 3" = 1'-0"4 EXTERIOR DOOR HEAD (BR)

SCALE: 3" = 1'-0"5 EXTERIOR DOOR HEAD (BR)

SCALE: 3" = 1'-0"6 INTERIOR DOOR HEAD

SCALE: 3" = 1'-0"10 EXTERIOR DOOR JAMB (BR)

SCALE: 3" = 1'-0"11 EXTERIOR DOOR JAMB (BR)

SCALE: 3" = 1'-0"7 INTERIOR DOOR JAMB

SCALE: 3" = 1'-0"8 EXTERIOR DOOR THRESHOLD

SCALE: 3" = 1'-0"9 EXTERIOR DOOR THRESHOLD

SCALE: 3" = 1'-0"12 INTERIOR FRAMED OPENING HEAD

SCALE: 3" = 1'-0"13 INTERIOR FRAMED OPENING JAMB

SEALANT; BOTH SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

SOUND BATTS; REFER TO PLAN(S)

WALL TYPES FOR LOCATION(S)

GYPSUM BOARD

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT, ATTACH TO

CMU, REFER TO DOOR SCHEDULE

CMU/SHOTCRETE/STUD WALL;

REFER TO FLOOR PLANS AND

WALL TYPES

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

CORNER BEAD

STEEL ANGLE; REFER

TO STRUCTURAL

GYPSUM BOARD; ATTACH TO STUD,

ADHERE TO ANGLE AND ABUT DOOR FRAME

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

METAL STUD HEADER;

REFER TO STRUCTURAL

5 3/4"

SEALANT; BOTH

SIDES,TYP.

DOOR; REFER TO

DOOR SCHEDULE

SHOTCRETE; REFER TO

STRUCTURAL FOR

THICKNESS AND LOCATION(S)

SOUND BATTS; REFER TO

PLAN(S) WALL TYPES FOR

LOCATION(S)

METAL STUD HEADER;

REFER TO STRUCTURAL

GYPSUM BOARD; ATTACH TO STUD,

ADHERE TO ANGLE AND ABUT DOOR FRAME

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT, ATTACH TO

CMU, REFER TO DOOR SCHEDULE

CMU/SHOTCRETE/STUD WALL;

REFER TO FLOOR PLANS AND

WALL TYPES

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

CORNER BEADCORNER BEAD

GYPSUM BOARD

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

STEEL ANGLE;

REFER TO STRUCTURAL

5 3/4"

SEALANT; BOTH

SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

GYPSUM BOARD

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT, ATTACH TO

CMU, REFER TO DOOR SCHEDULE

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

CORNER BEADCORNER BEAD

GYPSUM BOARD

CMU/STUD WALL; REFER TO

FLOOR PLANS AND WALL TYPES

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

SOUND BATTS; REFER TO

PLAN(S) WALL TYPES FOR

LOCATION(S)

GYPSUM BOARD; ATTACH TO

STUD AND ABUT DOOR FRAME

5 3/4"

SEALANT; BOTH SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

SOUND BATTS; REFER TO PLAN(S)

WALL TYPES FOR LOCATION(S)

GYPSUM BOARD

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT, ATTACH TO

CMU, REFER TO DOOR SCHEDULE

NEW/EXISTING CMU WALL;

REFER TO FLOOR PLAN AND

WALL TYPES

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

CORNER BEAD

STEEL ANGLE; REFER TO

STRUCTURAL

5 3/4"

GYPSUM BOARD; ATTACH TO STUD,

ADHERE TO ANGLE AND ABUT DOOR FRAME

SEALANT; BOTH

SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

SHOTCRETE; REFER TO

STRUCTURAL FOR THICKNESS

AND LOCATION(S)

SOUND BATTS; REFER TO PLAN(S)

WALL TYPES FOR LOCATION(S)

GYPSUM BOARD

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT, ATTACH TO

CMU, REFER TO DOOR SCHEDULE

CMU/SHOTCRETE/STUD WALL;

REFER TO FLOOR PLAN AND

WALL TYPES

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

GYPSUM BOARD

CORNER BEADCORNER BEAD

STEEL ANGLE; REFER

TO STRUCTURAL

GYPSUM BOARD; ATTACH STUD,

ADHERE TO ANGLE AND ABUT

DOOR FRAME

5 3/4"

SEALANT; BOTH

SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

SOUND BATTS; REFER TO

PLAN(S) WALL TYPES FOR

LOCATION(S)

GYPSUM BOARD

HOLLOW METAL DOOR FRAME,

FILL WITH GROUT, ATTACH TO

CMU, REFER TO DOOR SCHEDULE

CMU/STUD WALL; REFER

TO FLOOR PLANS AND

WALL TYPES

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

GYPSUM BOARD

CORNER BEADCORNER BEAD

GYPSUM BOARD; ATTACH TO

STUD AND ABUT DOOR FRAME

5 3/4"

STEEL BEAM, REFER TO

STRUCTURAL.

ROLL-UP DOOR MOTOR

STEEL PLATE, REFER TO

STRUCTURAL.

ROLL-UP DOOR HOOD

BREAK METAL TRIM; PRE-FINISHED

TO MATCH STOREFRONT SYSTEM

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

LAP FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

CMU, REFER TO STRUCTURAL

FOR REINFORCING AND LINTEL

INFORMATION

INSULATED METAL SOFFIT

PANELS; REFER TO EXTERIOR

MATERIAL & COLOR SCHEDULE

ROLL-UP OVERHEAD DOOR;

REFER TO DOOR SCHEDULE

SELF-ADHERING BITUTHANE

FLASHING WRAP; REFER TO

A625 FOR SEQUENCE

DRIP EDGE; PRE-FINISHED TO

MATCH STOREFRONT SYSTEM

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

CMU INFILL FOR DOOR

HOOD ATTACHMENT

EXISTING BRICK VENEER

AIR SPACE

EXISTING ANGLE

SEALANT; BOTH

SIDES, TYP.

EXISTING BRICK BEYOND

DOOR, REFER TO

DOOR SCHEDULE

EXISTING CMU

WALL

HOLLOW METAL DOOR

FRAME; FILL WITH GROUT,

ATTACH TO CMU, REFER

TO DOOR SCHEDULE

2" 5 3/4"

EXISTING CMU

BOND BEAM

EXISTING VAPOR

BARRIER (FIELD VERIFY

LOCATION AND MATERIAL) EXISTING BRICK

VENEER

AIR SPACE

SEALANT; BOTH

SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

EXISTING CMU

WALL

HOLLOW METAL DOOR FRAME;

FILL WITH GROUT ATTACH TO

CMU, REFER TO DOOR SCHEDULE

2" 5 3/4"

EXISTING VAPOR BARRIER

(FIELD VERIFY LOCATION

AND MATERIAL)

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A612

DO

OR

D

ET

AI

LS

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 3" = 1'-0"1 INTERIOR DOOR HEAD

SCALE: 3" = 1'-0"2 INTERIOR DOOR HEAD

SCALE: 3" = 1'-0"3 INTERIOR DOOR HEAD

SCALE: 3" = 1'-0"4 INTERIOR DOOR JAMB

SCALE: 3" = 1'-0"5 INTERIOR DOOR JAMB

SCALE: 3" = 1'-0"6 INTERIOR DOOR JAMB

SCALE: 3" = 1'-0"7 EXTERIOR DOOR HEAD (ROLL-UP DOOR)

SCALE: 3" = 1'-0"8 EXTERIOR DOOR HEAD

SCALE: 3" = 1'-0"9 EXTERIOR DOOR JAMB

ALUMINUM STOREFRONT

SYSTEM FRAME

THRESHOLD

6"

STEEL PLATE; REFER

TO STRUCTURE

WELD STEEL PLATE TO STEEL

TUBE; REFER TO STRUCTURAL

GYPSUM WALLBOARD

ALUMINUM STOREFRONT

SYSTEM FRAME

DOOR PANEL

THRESHOLD BELOW

STEEL TUBE; REFER TO

STRUCTURE

SEALANT; BOTH SIDES,

TYP.

METAL STUD WALL; REFER

TO PLAN(S) AND WALL TYPES

METAL CHANNEL

SEALANT, TYP.

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

BACKER-ROD & SEALANT

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

BRICK VENEER

BRICK VENEER/CMU/STUD

WALL; REFER TO FLOOR

PLAN AND WALL TYPES

BATT INSULATION

CORNER BEAD

STEEL TUBE; REFER TO

STRUCTURAL

METAL CHANNEL

GYPSUM BOARD; ATTACH TO METAL

CHANNEL, ADHERE TO STEEL PLATE

AND ABUT STOREFRONT FRAME

STEEL PLATE; ATTACH TO TUBE

STEEL; REFER TO STRUCTURAL

FLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS, APPLY TO

CONCEALED EDGE OF CMU PRIOR TO

INSTALLATION OF STEEL PLATE, REFER

TO EXTERIOR FINISH SCHEDULE4

1/ 2"

2"

SELF-ADHERING BITUTHANE

FLASHING WRAP; REFER TO

A625 FOR SEQUENCING

5 3/4"

SEALANT; BOTH SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

CMU/METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

GYPSUM BOARD; ATTACH TO CHANNEL,

ADHERE TO STEEL PLATE AND ABUT

DOOR FRAME

HOLLOW METAL DOOR

FRAME; FILL WITH

GROUT, REFER TO

DOOR SCHEDULE

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

METAL CHANNEL

SOUND BATTS; REFER TO

PLAN(S) AND WALL TYPES

FOR LOCATION(S)

STEEL TUBE; REFER

TO STRUCTURAL

CORNER BEAD

2"

SEALANT; BOTH SIDES, TYP.

DOOR, REFER TO

DOOR SCHEDULE

CMU/METAL STUD WALL;

REFER TO FLOOR PLAN

AND WALL TYPES

STUD HEADER; REFER

TO STRUCTURAL

GYPSUM BOARD

HOLLOW METAL DOOR

FRAME; CONCEAL

FASTENER, FILL WITH

GROUT, REFER TO DOOR

SCHEDULE

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

METAL CHANNEL

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL)

SOUND BATTS;

REFER TO PLAN(S)

AND WALL TYPES

FOR LOCATION(S)

5 3/4"

STEEL TUBE; REFER

TO STRUCTURAL

CORNER BEAD

4"

METAL TRACK; TRIM AT TUBE STEEL

EXTERIORINTERIOR

5/

8"

8 7/8" 6"

DIRECTIONAL MOTION

SENSOR BY SLIDING

DOOR MANUFACTURER

DIRECTIONAL MOTION

SENSOR BY SLIDING DOOR

MANUFACTURER

ACCESS COVER

GYPSUM BOARD

BATT INSULATION

STEEL PLATE; REFER

TO STRUCTURAL

METAL STUD WALL; REFER TO

FLOOR PLAN AND WALL TYPES

SEALANT; BOTH

SIDES, TYP.

CLOSURE STRIP BY SLIDING

DOOR MANUFACTURER

DIRECTIONAL MOTION SENSOR BY

SLIDING DOOR MANUFACTURER

ACCESS COVER

INTERIOR EXTERIOR

AUTOMATIC SLIDING DOOR. REFER

TO A201 FOR BASIS OF DESIGN

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

BREAK METAL TRIM; PRE-FINISH TO

MATCH STOREFRONT SYSTEM

GYPSUM BOARD

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

BACKER-ROD AND SEALANT

BATT INSULATION

CORNER BEAD

STEEL PLATE; REFER

TO STRUCTURAL

STEEL TUBE; REFER TO

STRUCTURAL

GYPSUM BOARD; ATTACH TO

CHANNEL, ADHERE TO STEEL PLATE

AND ABUT STOREFRONT FRAME

METAL TRACK;

TRIM AT TUBE STEEL

FLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS, APPLY

TO CONCEALED EDGE OF CMU PRIOR

TO INSTALLATION OF STEEL PLATE,

REFER TO EXTERIOR FINISH SCHEDULE

REFER TO STRUCTURAL FOR

REINFORCEMENT SIZE AND LOCATION(S)

LAP COAT OF FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

STUD FURRING; REFER

TO WALL TYPES

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

DIRECTIONAL MOTION SENSOR BY

SLIDING DOOR MANUFACTURER

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

4 1/2" 2"

BREAK METAL TRIM; PRE-FINISHED TO

MATCH STOREFRONT SYSTEM WITH

PRE-FORMED DRIP EDGE

GYPSUM BOARD

CONCRETE BEAM;

REFER TO STRUCTURAL

BACKER-ROD AND SEALANT

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

BATT INSULATION

GLAZING; REFER TO ELEVATIONS

AND GLAZING SCHEDULE

CORNER BEAD

STEEL PLATE; REFER

TO STRUCTURAL

STEEL TUBE; REFER TO

STRUCTURAL

GYPSUM BOARD; ATTACH TO

CHANNEL, ADHERE TO STEEL PLATE

AND ABUT STOREFRONT FRAME

METAL TRACK; TRIM AT TUBE STEEL

METAL HEADER; REFER

TO STRUCTURAL

5" 2"

METAL CHANNEL

SEALANT, TYP.

REFER TO STRUCTURAL FOR

REINFORCEMENT SIZE AND LOCATION(S)

STEEL CHANNEL; REFER

TO STRUCTURAL

STEEL CHANNEL; REFER

TO STRUCTURAL

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

CLOSURE STRIP BY

STOREFRONT MANUFACTURER

HEAD FLASHING, TYPE F; REFER TO A620

FOR FLASHING TYPES

LAP COAT OF FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

AIR SPACE

FLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS; APPLY

TO CONCEALED EDGE OF CMU

PRIOR TO INSTALLATION OF STEEL

PLATE AND/OR BRICK, REFER TO

EXTERIOR FINISH SCHEDULE

SEALANT; TYP.

STEEL TUBE; REFER TO

STRUCTURAL

BATT INSULATION

BRICK/CMU/METAL STUD WALL; REFER

TO FLOOR PLAN AND WALL TYPES

GYPSUM BOARDREFER TO STRUCTURAL

FOR CMU REINFORCEMENT

SIZE AND LOCATION(S)

STEEL PLATE; ATTACH TO TUBE

STEEL, REFER TO STRUCTURAL

BRICK VENEER/CMU/STUD

WALL; REFER TO WALL TYPES

METAL CHANNEL

SELF-ADHERING BITUTHANE

FLASHING WRAP AT OPENING;

REFER TO A625 FOR SEQUENCING

OVERHEAD DOOR; REFER

TO DOOR SCHEDULE

STEEL DOOR TRACK BY

OVERHEAD DOOR

MANUFACTURER; C2

COATING

ALUMINUM STOREFRONT

SYSTEM FRAME

TAPERED EXTRUSION

THRESHOLD

4 1/2"

1/ 2"

6"

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A613

DO

OR

D

ET

AI

LS

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 3" = 1'-0"1 DOOR SILL (BR)

SCALE: 3" = 1'-0"2 INTERIOR DOOR JAMB (BR)

SCALE: 3" = 1'-0"4 EXTERIOR DOOR JAMB (IR)

SCALE: 3" = 1'-0"6 INTERIOR DOOR JAMB (BR)

SCALE: 3" = 1'-0"7 INTERIOR DOOR HEAD (BR)

SCALE: 3" = 1'-0"3 INTERIOR DOOR HEAD (BR)

SCALE: 3" = 1'-0"5 EXTERIOR DOOR HEAD (IR)

SCALE: 3" = 1'-0"8 EXTERIOR STOREFRONT (HEAD @ TRANSOM) (BR)

SCALE: 3" = 1'-0"9 EXTERIOR DOOR JAMB

SCALE: 3" = 1'-0"10 DOOR SILL (IR)

6'-11"

6'- 8"

2'- 8"

2'- 4"

4'- 4"

GL-1 GL-1

GL-1 GL-1

EQEQ

9'- 4"

1/A622 3/A

2 3/A621

6/A621

7/A

4/A

1/A

5/A

3'- 0"

4'- 4"

3'-0"

7'- 4"

GL-2

6/A624

3/A

/A

6'-11"

2'- 4"

7'- 0"

EQ EQ

9'- 4"

GL-1 GL-1

1/A622 3/A621

4/A

1/A

9'- 4"

4'-2"

2'- 4"

4'- 4"

2'- 8"

GL-1

GL-1

GL-1

3/A

3/A621

4/A

8/A

10'-3"

9'- 4"

2'- 8"

4'- 4"

2'- 4"

EQ EQ EQ

GL-1GL-1 GL-1

GL-1GL-1 GL-1

GL-1GL-1 GL-1

1/A622

3/A

8/A

/A

10/A621

7/A

3/A621

9'- 4"

10'-3"

7'- 0"

2'- 8"

4'- 4"

2'- 4"

2'-1 1/2" 6'-0" 2'-1 1/2"

GL-1

GL-1

GL-1

GL-1

GL-1

GL-1GL-12/A622

6/A

3/A

5/A622

7/A

/A

10/A621

9/A621

8/A

3/A621

6'-11"

9'- 4"

2'- 4"

4'- 4"

2'- 8"

3'-3 1/2" 3'-0"

7'- 0"

GL-1

GL-1

GL-1 GL-1

2/A622

5/A622

3/A

2 6/A

9/A622 8/A622

4/A

7/A

3/A621

6/A621

11/A622 10/A622

8/A

GL-4 GL-4

GL-3

GL-4

GL-3

GL-3GL-3

9'- 4"

2'- 4"

4'- 4"

2'- 8"

10'-0" 2'-0" 6'-0" 2'-0"

7'- 0"

/A

7/A

5/A624

9/A624

2/A

1/A

5/A623

6/A

GL-4

GL-4 GL-4

GL-3 GL-3

GL-3 GL-3

2'- 4"

4'- 4"

2'- 8"

9'- 4"

8'-0" 2'-6" 3'-0" 2'-6"

7'- 0"

6/A624

1/A

2/A

7/A

/A

9/A624

/A

5/A624

5'-6"

9'- 4"

2'-0 3/4"3'-0"

2'- 8"

4'- 4"

2'- 4"

GL-4 GL-4

GL-3

7'- 0"

GL-3

6/A624

/A

1/A

2/A

4/A624

7/A

/A

9/A624

5/A624

16'-0"

9'- 4"

6'-0"

2'- 4"

4'- 4"

2'- 8"

EQ EQ EQ EQ

7'- 0"

GL-4GL-4GL-4 GL-4GL-4

GL-3GL-3

GL-3GL-3

GL-3GL-3 GL-3GL-3

6/A624

8/A624

5/A624

/A

/A

2/A

7/A

9/A624

1/A

9'- 4"

2'- 8"

4'- 4"

2'- 4"

GL-3GL-3GL-3GL-3 GL-3 GL-3 GL-3

GL-4GL-4GL-4GL-4 GL-4 GL-4 GL-4

GL-3GL-3GL-3GL-3 GL-3 GL-3 GL-3

/A

7/A

1/A

8/A624

SPECIAL JAMB SHAPE; REFER TO

STOREFRONT MANUFACTURER

28'-0"

9'- 4"

6'-0"

2'- 4"

4'- 4"

2'- 8"

7'- 0"

EQEQEQ EQ EQ EQ

GL-4GL-4GL-4GL-4 GL-4GL-4GL-4

GL-3GL-3GL-3 GL-3GL-3GL-3

GL-3GL-3GL-3 GL-3GL-3GL-3

6/A6248/A6245/A624

9/A624

/A

2/A

1/A

7/A

/A

21'-0"

9'- 4"

2'- 4"

4'- 4"

2'- 8"

EQEQEQEQEQEQ

GL-4GL-4GL-4 GL-4 GL-4 GL-4

GL-3GL-3GL-3 GL-3 GL-3 GL-3

GL-3GL-3GL-3 GL-3 GL-3 GL-3

6/A6248/A624

7/A

1/A

/A

9'- 4"

10'-5 1/4"

EQ EQ EQ

2'- 4"

4'- 4"

2'- 8"

GL-3

GL-4

GL-3

GL-3

GL-4

GL-3

GL-3

GL-4

GL-3

6/A6248/A624

7/A

1/A

/A

GL-4

6'-3 1/2"

9'- 4"

6'-0"7'- 0"

2'- 4"

4/A62411 /A

/A

2/A

6/A

1/A623

GLAZING TYPES

MARK

GL-1 BRONZE, BLAST RESISTANT, LOW E, LAMINATED,

INSULATED GLAZING UNITS

GL-2

GL-3

GL-4

GL-5

DESCRIPTION

REFER TO SPEC SECTION 08 81 00

SIZE

1 5/16"

GL-6

GL-7 MIRROR

9/16"

1/4" 1/4" 9/16"

9/16"

BRONZE, BLAST RESISTANT, LOW E, LAMINATED

GLAZING UNITS

TEMPERED GLASS

CLEAR GLASS

BRONZE, LOW E, LAMINATED, WINDBORNE DEBRIS

IMPACT RATED GLAZING UNITS

CLEAR, BLAST RESISTANT, LAMINATED GLAZING UNITS

9'- 4"

2'- 4"

7'- 0"

3'-5"

GL-1

6/A

8/A622

4/A

10/A622

9'- 4"

2'- 8"

4'- 4"

2'- 4"

5'-9"

EQ EQ

GL-1 GL-1

GL-1 GL-1

GL-1 GL-1

1/A622

3/A

10/A621

9/A621

8/A

7/A

/A

3'-9 1/2"

22'-0"4'-5 3/8" 4'-4 1/2" 4'-4 1/2" 4'-4 1/2" 4'-5 3/8"

3'-9 1/2

SPECIAL JAMB SHAPE; REFER TO

STOREFRONT MANUFACTURER

9'- 4"

2'- 8"

4'- 4"

2'- 4"

10'-0"

2'-0"3'-0"2'-6"2'-6"

7'- 0"

GL-4GL-4GL-4 GL-4

GL-3GL-3 GL-3

GL-3GL-3 GL-3

6/A624

5/A624

8/A624

1/A

2/A

9/A624

/A

/A

7/A

GL-1 GL-1 GL-1 GL-1GL-1

1/A622

23'-11 3/8"

4'-6 1/8" 2'-6" 5'-7 1/8" 5'-8 1/8" 5'-8 1/8" 4'-

8" 4/A623

2/A

3/A

GL-1 GL-1

GL-1GL-1

GL-1

1/A622

23'-3 3/4"

5'-3" 5'-4 1/2" 5'-0 1/2" 2'-7 1/2" 5'-0 1/4"

2'- 4"

1'- 2"

1'- 2"

4'- 8"

4/A623

3/A

2/A

LEGEND

SYMBOL

SECTION MARK @ STOREFRONT

DESCRIPTION

1/A600

9'- 4"

2'- 4"

7'- 0"

3'-3 1/2" 3'-0"

4/A624

6/A624

/A

/A

2/A

5" M

IN

5"

STEP FLASHING

TYPE A

WALL TO ROOF FLASHING

TYPE B

6" M

IN

4"

1/ 2"

THROUGH WALL FLASHING

TYPE C

3"MIN.

3/ 4"

EAVE FLASHING

TYPE D

3/4" OVERHANG

1/4" DRIP EDGE

3"MIN.

3/

4" 3/4" OVERHANG

1/4" DRIP EDGE

RAKE FLASHING

TYPE E

4"

SIZE TO FIT

1/4" DRIP EDGE

HEAD FLASHING

TYPE F

VA

RI

ES

SIZE TO FIT

1/ 2"

3" (+/-) VARIES

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A620

ST

OR

EF

RO

NT

E

LE

VA

TI

ON

S N

OT

ES

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE A

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE C

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE B

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE D

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE G

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE H

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE L

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE M

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE N

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE P

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE Q

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE S

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE T

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE U

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE V

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE X

STOREFRONT & WINDOW NOTES

1 GLAZING SPECIFIED IN SECTION 08 81 00

2 BASIS OF DESIGN FOR BLAST RESISTANT STOREFRONT & WINDOWS - EFCO

S526 (T)

3 BASIS OF DESIGN FOR INTERIOR STOREFRONT & WINDOWS - EFCO S401

4 EXTERIOR ENTRANCE DOOR, BASIS OF DESIGN - EFCO D300, MEDIUM STILE

5 INTERIOR ENTRANCES IN STOREFRONT TO BE WOOD.

6 ALL SURFACES OF STRUCTURAL STEEL PLATES, CHANNELS, COLUMNS AND

ANGLES USED TO RE-INFORCE OPENINGS FOR AT-FP SHALL BE FINISHED

WITH COATING 1 (C1); REFER TO A201 EXTERIOR MATERIAL & COLOR

LEGEND, AND SPECIFICATION SECTION 09 97 13.00 40 STEEL COATINGS.

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE K

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE J

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE S PLAN

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE W

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE Z

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE Y

(EXTERIOR-BR)

SCALE: 1/4" = 1'-0"

STOREFRONT TYPE R

SCALE: 6" = 1'-0"

FLASHING TYPES

NEW ROWLOCK SILL

SEALANT

END DAMN; SEAL TO ADJACENT BRICK

BRICK/CMU/METAL STUD WALL; REFER

TO FLOOR PLAN AND WALL TYPES

GYPSUM BOARD

STEEL TUBE - REFER

TO STRUCTURAL

SEALANT ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

BATT INSULATION

EXISTING CMU

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

SOLID SURFACE WINDOW STOOL;

ADHERE TO STEEL PLATE & ATTACH TO

METAL STUD; PLUG ATTACHMENT HOLES,

REFER TO COLOR SCHEDULE

EXISTING BRICK VENEER

METAL CHANNEL; TRIM

AT TUBE STEEL

METAL CHANNEL

5" 2"

ROPE WEEPS @ 6 INCHES O.C.;

DO NOT SEAL ABOVE FLASHING

THROUGH WALL FLASHING; REFER

TO SPEC SECTION XX.XX.XX

STEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

SEALANT

CMU LINTEL BLOCK;

REFER TO STRUCTURAL

FLUID APPLIED VAPOR BARRIER AT NEW

CMU LOCATIONS, EXTEND OVER EXISTING

CMU IF POSSIBLE; APPLY TO CONCEALED

EDGE OF CMU PRIOR TO INSTALLATION OF

STEEL PLATE; REFER TO EXTERIOR

MATERIAL & COLOR SCHEDULE

SILL FLASHING

GYPSUM BOARD

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

BATT INSULATION

CORNER BEAD

STEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

STEEL TUBE; REFER TO

STRUCTURAL

GYPSUM BOARD; ATTACH TO

CHANNEL, ADHERE TO STEEL PLATE

AND ABUT STOREFRONT FRAME

METAL TRACK; TRIM AT TUBE STEEL

METAL HEADER; REFER

TO STRUCTURAL

METAL CHANNEL

SEALANT, TYP.

BREAK METAL TRIM; PRE-FINISHED

TO MATCH STOREFRONT SYSTEM

LAP FLUID APPLIED VAPOR BARRIER

OVER METAL FLASHING

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

BACKER-ROD AND SEALANT

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

SELF-ADHERING BITUTHANE FLASHING

WRAP, REFER TO A625 FOR SEQUENCE

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

CLOSURE STRIP BY STOREFRONT

MANUFACTURER

5" 2"

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

SEALANT, TYP.

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

GLAZING; REFER TO

STOREFRONT ELEVATIONS

& GLAZING SCHEDULE

BACKER-ROD & SEALANT

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

EXISTING BRICK VENEER

BRICK/CMU/METAL STUD; REFER

TO FLOOR PLAN AND WALL TYPES

BATT INSULATION

CORNER BEAD

EXISTING CMU

STEEL TUBE; REFER TO

STRUCTURALSTEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

METAL CHANNEL

2" 5"

GYPSUM BOARD; ATTACH TO METAL

CHANNEL, ADHERE TO STEEL PLATE

AND ABUT STOREFRONT FRAME

FLUID APPLIED VAPOR BARRIER, APPLY TO

CONCEALED EDGES OF EXISTING CMU, IF

POSSIBLE, PRIOR TO INSTALLATION OF

STEEL TUBE COLUMN, REFER TO EXTERIOR

MATERIAL & COLOR SCHEDULE

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

CLOSURE STRIP BY

STOREFRONT MANUFACTURER

CMU LINTEL BLOCK; REFER

TO STRUCTURAL

NEW ROWLOCK SILL

SEALANT

END DAMN; SEAL TO ADJACENT BRICK

METAL STUDS; ALIGN TOP TRACK

WITH TOP OF STEEL PLATE

GYPSUM BOARD

STEEL PLATE, WELD TO STEEL

ANGLE; REFER TO STRUCTURAL

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

BATT INSULATION

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

EXISTING BRICK VENEER

EXISTING CMU

STEEL ANGLE; REFER

TO STRUCTURAL

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

SOLID SURFACE WINDOW STOOL;

ADHERE TO STEEL PLATE & ATTACH TO

METAL STUD; PLUG ATTACHMENT

HOLES. REFER TO COLOR SCHEDULE

THROUGH WALL FLASHING; REFER

TO SPEC SECTION XX.XX.XX

SEALANT

5" 2"

BRICK/CMU/SHOTCRETE WALL; REFER

TO FLOOR PLAN AND WALL TYPES

SEALANT

ROPE WEEP @ 6 INCHES O.C.,

DO NOT SEAL ABOVE FLASHING

FLUID APPLIED VAPOR BARRIER AT NEW CMU

LOCATIONS, EXTEND OVER EXISTING CMU IF

POSSIBLE; APPLY TO CONCEALED EDGE OF

CMU PRIOR TO INSTALLATION OF STEEL

PLATE; REFER TO EXTERIOR MATERIAL &

COLOR SCHEDULE

SILL FLASHING

GYPSUM BOARD; ADHERE TO STEEL

PLATE, ATTACH TO METAL STUD

AND ABUT STOREFRONT SYSTEM

SEALANT, TYP.

ALUMINUM STOREFRONT

SYSTEM JAMB; ATTACH TO

STEEL PLATE

GLAZING; REFER TO

GLAZING SCHEDULE

BACKER-ROD & SEALANT

ROW-LOCK BRICK SILL

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

EXISTING BRICK VENEER

BRICK/CMU/SHOTCRETE/METAL

STUD WALL; REFER TO FLOOR

PLAN AND WALL TYPES

BATT INSULATION

CORNER BEAD

EXISTING CMU

SHOTCRETE; REFER TO

STRUCTURAL FOR THICKNESS

AND LOCATION(S)

STEEL ANGLE - REFER TO

STRUCTURAL

STEEL PLATE, WELD TO STEEL

ANGLE; REFER TO STRUCTURAL

FLUID APPLIED VAPOR BARRIER, APPLY TO

CONCEALED EDGES OF EXISTING CMU, IF

POSSIBLE, PRIOR TO INSTALLATION OF

STEEL TUBE COLUMN, REFER TO EXTERIOR

MATERIAL & COLOR SCHEDULE

SELF-ADHERING BITUTHANE FLASHING WRAP;

REFER TO A625 FOR SEQUENCING

CLOSURE STRIP BY

STOREFRONT MANUFACTURER 2"

5"

BREAK METAL TRIM; PRE-FINISHED TO

MATCH STOREFRONT SYSTEM

LAP FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

METAL STUD/SHOTCRETE/CMU

WALL; REFER TO FLOOR PLAN

AND WALL TYPES

GYPSUM BOARD

CMU LINTEL BLOCK(S);

REFER TO STRUCTURAL

BACKER-ROD AND SEALANT

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

BATT INSULATION

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

CORNER BEAD

STEEL PLATE, WELD TO STEEL

ANGLE; REFER TO STRUCTURAL

STEEL ANGLE; REFER

TO STRUCTURAL

GYPSUM BOARD; ATTACH TO METAL

STUD, ADHERE TO STEEL PLATE AND

ABUT STOREFRONT FRAME

5" 2"

SELF-ADHERING BITUTHANE FLASHING

WRAP, REFER TO A625 FOR SEQUENCE

REFER TO STRUCTURAL FOR

REINFORCEMENT SIZE AND LOCATION(S)

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

CLOSURE STRIP BY STOREFRONT

MANUFACTURERGLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO SLAB

SEALANT

SILL PLATE

BRICK VENEER BEYOND

EXPANSION JOINT;

REFER TO STRUCTURAL

CONCRETE SIDEWALK;

REFER TO CIVIL DWGS.

EXISTING CONCRETE SLAB;

REFER TO STRUCTURAL

5" 2"

METAL STUD FRAMING

GLAZING; REFER TO

STOREFRONT ELEVATIONS

& GLAZING SCHEDULE

SEALANT, TYP.

STEEL BEAM - REFER TO

STRUCTURAL

GYPSUM BOARD; ADHERE

TO STEEL PLATE AND ABUT

STOREFRONT FRAME

METAL STUD; REFER TO FLOOR

PLAN AND WALL TYPES

BATT INSULATION

STEEL PLATE, WELD TO

STEEL BEAM; REFER TO

STRUCTURAL

GYPSUM BOARD

CORNER BEAD BREAK METAL TRIM; PRE-FINISHED

TO MATCH STOREFRONT SYSTEM

LAP FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

BACKER-ROD AND SEALANT

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE

SELF-ADHERING BITUTHANE

FLASHING WRAP, REFER TO A625

FOR SEQUENCE

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

CLOSURE STRIP BY STOREFRONT

MANUFACTURER

5" 2"

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

GYPSUM BOARD; ATTACH TO

METAL STUD, ADHERE TO STEEL

PLATE, ABUT STOREFRONT FRAME

STEEL TUBE COLUMN;

REFER TO STRUCTURAL

SEALANT, TYP.

ALUMINUM STOREFRONT

SYSTEM FRAME; ATTACH TO

STEEL PLATE

GLAZING; REFER TO

STOREFRONT ELEVATIONS

& GLAZING SCHEDULE

CLOSURE STRIP BY

STOREFRONT MANUFACTURER

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

EXISTING BRICK VENEER

BRICK/CMU/METAL STUD WALL;

REFER TO FLOOR PLAN(S) AND

WALL TYPES

BATT INSULATION

CORNER BEAD

EXISTING CMU

5" 2"

STEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

FLUID APPLIED VAPOR BARRIER, APPLY

TO CONCEALED EDGES OF EXISTING CMU,

IF POSSIBLE, PRIOR TO INSTALLATION OF

STEEL TUBE COLUMN, REFER TO

EXTERIOR MATERIAL & COLOR SCHEDULE

BACKER-ROD & SEALANT

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

BREAK METAL TRIM; PRE-FINISHED

TO MATCH STOREFRONT SYSTEM

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL

SEALANT, TYP.

BREAK METAL TRIM; PRE-FINISHED

TO MATCH STOREFRONT SYSTEM

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

WRAP COLUMN WITH SELF-

ADHERING BITUTHANE FLASHING

WRAP PRIOR TO INSTALLING

BREAK METAL TRIM

SEALANT, TYP.

EXTERIOR

INTERIOR

STEEL PLATE; BOLT TO STEEL

TUBE; REFER TO STRUCTURAL

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

FACE OF BRICK

2"

3" 3"

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A621

EX

TE

RI

OR

S

TO

RE

FR

ON

T

DE

TA

IL

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

141SCALE: 3" = 1'-0"1 EXTERIOR STOREFRONT SILL (BR)

SCALE: 3" = 1'-0"4 EXTERIOR STOREFRONT HEAD (BR)

SCALE: 3" = 1'-0"3 EXTERIOR STOREFRONT JAMB (BR)

SCALE: 3" = 1'-0"5 EXTERIOR STOREFRONT SILL (BR)

SCALE: 3" = 1'-0"6 EXTERIOR STOREFRONT JAMB (BR)

SCALE: 3" = 1'-0"7 EXTERIOR STOREFRONT HEAD (BR)

SCALE: 3" = 1'-0"8 EXTERIOR STOREFRONT SILL

SCALE: 3" = 1'-0"11 EXTERIOR STOREFRONT HEAD (BR)

SCALE: 3" = 1'-0"9 EXTERIOR STOREFRONT JAMB (BR)

SCALE: 3" = 1'-0"10 EXTERIOR STOREFRONT JAMB (BR)

2 1/2"

5"

ALUMINUM STOREFRONT

SYSTEM FRAME

GLAZING; REFER TO ELEVATIONS

AND GLAZING SCHEDULE

5"

2 1/2" 7/8"

ALUMINUM STOREFRONT

SYSTEM FRAME

GLAZING; REFER TO ELEVATIONS

AND GLAZING SCHEDULE

GLAZING; REFER TO ELEVATIONS

AND GLAZING SCHEDULE

ALUMINUM STOREFRONT

SYSTEM FRAME

5"

1/

2"

DOOR; REFER TO

DOOR SCHEDULE

ALUMINUM STOREFRONT

SYSTEM FRAME

GLAZING; REFER TO ELEVATIONS

AND GLAZING SCHEDULE

2 1/2"

5"

GLAZING; REFER TO ELEVATIONS

AND GLAZING SCHEDULE

ALUMINUM STOREFRONT

SYSTEM FRAME

DOOR; REFER TO

DOOR SCHEDULE

1/

2" 5"

SEALANT, TYP.

STEEL TUBE; REFER

TO STRUCTURAL

METAL STUD

BATT INSULATION

GYPSUM BOARD; ADHERE TO STEEL

PLATE, ATTACH TO METAL STUD

AND ABUT STOREFRONT FRAME

STEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

CORNER BEAD

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

BREAK METAL TRIM; PRE-FINISHED TO

MATCH STOREFRONT SYSTEM

LAP FLUID APPLIED VAPOR

BARRIER OVER METAL FLASHING

EXISTING CONCRETE BEAM;

REFER TO STRUCTURAL

BACKER-ROD AND SEALANT

ALUMINUM STOREFRONT SYSTEM

FRAME; ATTACH TO STEEL PLATE5" 2"

SELF-ADHERING BITUTHANE FLASHING

WRAP, REFER TO A625 FOR SEQUENCE

HEAD FLASHING, TYPE F; REFER

TO A620 FOR FLASHING TYPES

ROPE WEEPS @ 6 INCHES O.C.;

CAULK BETWEEN WEEPS ONLY

CLOSURE STRIP BY STOREFRONT

MANUFACTURER

3/8" ENGINEERED SEALANT

JOINT WITH BACKER-ROD

GYPSUM BOARD

METAL CHANNEL

SEALANT

ALUMINUM STOREFRONT SYSTEM

JAMB; ATTACH TO STEEL PLATE

DOOR PANEL

BACKER-ROD & SEALANT

REFER TO STRUCTURAL FOR

CMU REINFORCEMENT SIZE

AND LOCATION(S)

EXISTING BRICK VENEER

METAL STUD/CMU WALL; REFER

TO PLAN(S) AND WALL TYPES

BATT INSULATION

CORNER BEAD

EXISTING CMU

STEEL TUBE; REFER

TO STRUCTURAL

STEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

2" 5"

METAL TRACK; TRIM

AT TUBE STEEL

GYPSUM BOARD; ADHERE TO

STEEL PLATE, ATTACH TO

METAL CHANNEL AND ABUT

STOREFRONT FRAME

FLUID APPLIED VAPOR BARRIER AT NEW

CMU WALL LOCATIONS, APPLY TO

CONCEALED EDGE OF CMU PRIOR TO

INSTALLATION OF STEEL PLATE, REFER TO

EXTERIOR MATERIAL & COLOR SCHEDULE

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

SEALANT

ALUMINUM STOREFRONT SYSTEM

JAMB; ATTACH TO STEEL PLATE

DOOR PANEL

BACKER-ROD & SEALANT

REFER TO STRUCTURAL FOR CMU

REINFORCEMENT SIZE AND LOCATION(S)

EXISTING BRICK VENEER

METAL STUD/SHOTCRETE/CMU WALL;

REFER TO PLAN(S) AND WALL TYPES

BATT INSULATIONCORNER BEAD

EXISTING CMU

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

STEEL ANGLE; REFER TO

STRUCTURAL

STEEL PLATE - REFER

TO STRUCTURAL DWGS.

GYPSUM BOARD; ADHERE TO STEEL

PLATE, ATTACH TO METAL STUD AND

ABUT STOREFRONT FRAME

2" 5"

FLUID APPLIED VAPOR BARRIER;

APPLY TO CONCEALED EDGE OF

EXISTING CMU, IF POSSIBLE, PRIOR

TO INSTALLATION OF STEEL PLATE,

REFER TO EXTERIOR MATERIAL &

COLOR SCHEDULE

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

METAL CHANNEL

METAL TRACK; TRIM

AT TUBE STEEL

SEALANT

ALUMINUM STOREFRONT SYSTEM

JAMB; ATTACH TO STEEL PLATE

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

BACKER-ROD & SEALANT

REFER TO STRUCTURAL FOR

CMU REINFORCEMENT SIZE

AND LOCATION(S)

EXISTING BRICK VENEER

METAL STUD/CMU WALL; REFER

TO PLAN(S) AND WALL TYPES

BATT INSULATION

CORNER BEAD

EXISTING CMU

STEEL TUBE - REFER

TO STRUCTURAL DWGS.

STEEL PLATE, WELD TO STEEL

TUBE; REFER TO STRUCTURAL

2" 5"

GYPSUM BOARD; ADHERE TO STEEL PLATE, ATTACH

TO METAL CHANNEL AND ABUT STOREFRONT FRAME

FLUID APPLIED VAPOR BARRIER AT

NEW CMU WALL LOCATIONS, APPLY

TO CONCEALED EDGE OF CMU PRIOR

TO INSTALLATION OF STEEL PLATE,

REFER TO EXTERIOR MATERIAL &

COLOR SCHEDULE

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

SEALANT

ALUMINUM STOREFRONT SYSTEM

JAMB; ATTACH TO STEEL PLATE

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

BACKER-ROD & SEALANT

REFER TO STRUCTURAL FOR

CMU REINFORCEMENT SIZE

AND LOCATION(S)

EXISTING BRICK VENEER

METAL STUD/SHOTCRETE/CMU WALL;

REFER TO PLAN(S) AND WALL TYPES

BATT INSULATIONCORNER BEAD

EXISTING CMU

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

STEEL ANGLE; REFER TO

STRUCTURAL

STEEL PLATE, WELD TO STEEL

ANGLE; REFER TO STRUCTURAL

2" 5"

GYPSUM BOARD; ADHERE TO STEEL

PLATE, ATTACH TO METAL STUD AND

ABUT STOREFRONT FRAME

FLUID APPLIED VAPOR BARRIER; APPLY

TO CONCEALED EDGE OF CMU, IF

POSSIBLE, PRIOR TO INSTALLATION OF

STEEL PLATE, REFER TO EXTERIOR

MATERIAL & COLOR SCHEDULE

SELF-ADHERING BITUTHANE FLASHING

WRAP; REFER TO A625 FOR SEQUENCING

GLAZING; REFER TO

STOREFRONT ELEVATIONS

& GLAZING SCHEDULE

ALUMINUM STOREFRONT DOOR;

REFER TO DOOR SCHEDULE

BRICK VENEER BEYOND

THRESHOLD; SET IN MASTIC; REFER

TO DOOR SCHEDULE & HARDWARE

SETS

EXPANSION JOINT;

REFER TO STRUCTURAL

CONCRETE SIDEWALK;

REFER TO CIVIL

EXISTING CONCRETE SLAB;

REFER TO STRUCTURAL

5" 2"

GLICK/BOEHM

CHARLESTON

NO. B-80006 T

CE

TIHCRADER

ET

SI

G E

R

TH CARO

LIN

A

S

TA

TE

OF

SOU

& ASSOCIATES, INC.

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

OFSHEET

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T

HE

A

IR

F

OR

C E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

A622

EX

TE

RI

OR

S

TO

RE

FR

ON

T

DE

TA

IL

S

GB

KR

S

SM

/30

/20

AD

D/

RE

PA

IR

P

AS

SE

NG

ER

T

ER

M

IN

AL

B

UI

LD

IN

G

DKFX:11-1122 A / B

SCALE: 3" = 1'-0"1 EXTERIOR STOREFRONT (VERTICAL MULLION)

SCALE: 3" = 1'-0"2 EXTERIOR STOREFRONT (SIDELITE @ TRANSOM)

SCALE: 3" = 1'-0"3 EXTERIOR STOREFRONT (HORIZONTAL MULLION)

SCALE: 3" = 1'-0"5 EXTERIOR STOREFRONT (DOOR JAMB @ SIDELITE) (BR)

SCALE: 3" = 1'-0"6 EXTERIOR STOREFRONT (DOOR HEAD @ TRANSOM) (BR)

SCALE: 3" = 1'-0"7 EXTERIOR STOREFRONT HEAD (BR)

SCALE: 3" = 1'-0"8 EXTERIOR STOREFRONT DOOR JAMB (BR)

SCALE: 3" = 1'-0"9 EXTERIOR STOREFRONT DOOR JAMB (BR)

SCALE: 3" = 1'-0"10 EXTERIOR STOREFRONT WINDOW JAMB (BR)

SCALE: 3" = 1'-0"11 EXTERIOR STOREFRONT WINDOW JAMB (BR)

SCALE: 3" = 1'-0"12 EXTERIOR STOREFRONT THRESHOLD (BR)

STEEL CHANNEL; REFER

TO STRUCTURAL

EXISTING CMU

GLAZING

CORNER BEAD

SEALANT; BOTH SIDES, TYP.

ALUMINUM STOREFRONT

SYSTEM FRAME

CORNER BEAD

SHOTCRETE; REFER TO

STRUCTURAL

METAL STUD/SHOTCRETE/CMU

WALL; REFER TO FLOOR PLAN(S)

AND WALL TYPES

STEEL CHANNEL; REFER

TO STRUCTURAL

THREADED THRU-RODS;

REFER TO STRUCTURAL

GYPSUM WALLBOARDGYPSUM WALLBOARD

SHOTCRETE; REFER TO STRUCTURAL

FOR THICKNESS AND LOCATION(S)

STUD/SHOTCRETE/CMU WALL; REFER

TO FLOOR PLANS AND WALL TYPES

GYPSUM WALLBOARD

DOUBLE STUD

AT JAMBS

CORNER BEAD

ALUMINUM STOREFRONT

SYSTEM FRAME

GLAZING; REFER TO STOREFRONT

ELEVATIONS & GLAZING SCHEDULE

EXISTING CMU

3-5/8" METAL STUD

GYPSUM WALLBOARD

REFER TO STRUCTURAL FOR

REINFORCEMENT QUANTITY,

SIZE AND LOCATION(S)

CORNER BEAD

SEALANT; BOTH SIDES, TYP.

WD SHIM

GYPSUM…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .