F1
HOLLOW METAL
DO
OR
H
EI
GH
T
WIDTH
DOOR
NOTE: REFER TO A620 FOR STOREFRONT ELEVATIONS
F2
HOLLOW METAL
DO
OR
H
EI
GH
T
WIDTH
DOOR
FRAMED OPENING;
SMOOTH FRAME
(NO RABITS)
2" 2" 2" 2"
4" 4"
GLAZING TYPES
MARK
GL-1 BRONZE, BLAST RESISTANT, LOW E, LAMINATED,
INSULATED GLAZING UNITS
GL-2
GL-3
GL-4
GL-5
DESCRIPTION
REFER TO SPEC SECTION 08 81 00
SIZE
1 5/16"
GL-6
GL-7 MIRROR
9/16"
1/4" 1/4" 9/16"
9/16"
BRONZE, BLAST RESISTANT, LOW E, LAMINATED
GLAZING UNITS
TEMPERED GLASS
CLEAR GLASS
BRONZE, LOW E, LAMINATED, WINDBORNE DEBRIS
IMPACT RATED GLAZING UNITS
CLEAR, BLAST RESISTANT, LAMINATED GLAZING UNITS
D1
FLUSH
D2
FULL
VISION
D3
OVERHEAD
ROLLING
D4
SLIDING
(IR)
D5
SLIDING
(BR)
6" 6"
6" 1'-
0"
NOTE: REFER TO DOOR & FRAME SCHEDULE FOR GLAZING TYPE IN DOORS
DO
OR
H
EI
GH
T
DOOR WIDTH
DOOR WIDTH
DO
OR
H
EI
GH
T
DOOR WIDTH
DO
OR
H
EI
GH
T
14'-0" R.O. 14'-0" R.O.
7'- 8"
R .O
7'-
/2
" R .O
7'- 0"
EQ. DOOR WIDTH EQ.
7'-
1/ 2"
EQ. DOOR WIDTH EQ.
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A610
DO
OR
S C
HE
DU
LE
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
DOOR & FRAME SCHEDULE
TAG TYPE
DOOR FRAME HARDWARE
SET
DETAILS
NOTES TAGMATERIAL WIDTH HEIGHT THICKNESS FINISH GLAZING TYPE MATERIAL FINISH HEAD JAMB SILL 101A D4 ALUM 13' - 8 1/2" 7' - 0" 0' - 1 3/4" DK BRZ GL-5 INTEGRAL ALUM DK BRZ 01 5/A613 4/A613 10/A613 SLIDING, MOTION DETECTION, IR, E 101A 101B D5 ALUM 13' - 7" 7' - 0 1/2" 0' - 2 1/2" DK BRZ GL-6 INTEGRAL ALUM DK BRZ 01 3/A613 2/A613 1/A613 SLIDING, MOTION DETECTION, BR, E 101B 105 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A611 2/A611 1/A611 105 106 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 W/A620 ALUM DK BRZ 03 11/A624 5/A624 -- 106 107 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 P/A620 ALUM DK BRZ 03 11/A624 4/A624 & 5/A624 2/A624 107 108 D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 K/A620 ALUM DK BRZ 04 6/A622 8/A622 12/A622 BR 108 109 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A611 2/A611 -- 109 110 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 06 3/A612 6/A612 1/A611 110 111 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A612 6/A612 1/A611 111 112 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A611 2/A611 -- 112 114 D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 L/A620 ALUM DK BRZ 07 6/A622 9/A622 & 5/A622 12/A622 BR 114 115 D1 WD 5' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 08 3/A611 2/A611 -- 115 117 D1 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 09 3/A611 2/A611 1/A611 117 118 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A611 2/A611 -- 118 119 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A611 2/A611 -- 119 120 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 10 3/A611 2/A611 1/A611 120 121 D1 WD 2' - 6" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 11 3/A611 2/A611 -- 121 122 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 12 3/A611 2/A611 1/A611 122 123 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 12 3/A611 2/A611 1/A611 123
124A D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 13 6/A611 7/A611 8/A611 (SIM) 124A 124B D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 14 4/A611 10/A611 8/A611 BR 124B 124C D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 (SIM) 9/A613 -- NOTE 4, IR, E 124C 125 D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 15 8/A612 9/A612 8/A611 125 126 D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 40 5/A611 (SIM) 11/A611 (SIM) 9/A611 BR 126
127A D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 17 3/A611 2/A611 1/A611 127A 127B D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 17 3/A611 2/A611 -- 127B 127C D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 L/A620 ALUM DK BRZ 07 6/A622 8/A622 & 5/A622 12/A622 BR 127C 127D D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 18 7/A613 6/A613 1/A611 BR 127D 128 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A611 2/A611 1/A611 128 129 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 20 3/A611 2/A611 1/A611 129 130 D1 WD 2' - 6" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 130 131 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 20 3/A611 2/A611 1/A611 131 132 D1 WD 2' - 6" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 132 133 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 26 3/A611 2/A611 -- 133 134 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 05 3/A612 5/A612 & 6/A612 1/A611 134 135 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A612 6/A612 -- 135 136 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 02 3/A612 6/A612 -- 136
138A D3 STEEL 14' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4, IR, E 138A 138B D3 STEEL 14' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4, IR, E 138B 142 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 N/A620 ALUM DK BRZ 03 11/A624 5/A624 2/A624 142 143 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 10 3/A611 2/A611 1/A611 143
144A D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- R/A620 ALUM DK BRZ 23 11/A624 4/A624 2/A624 144A 144B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 25 6/A622 5/A622 12/A622 BR, E 144B 145 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 24 3/A611 2/A611 1/A611 145 146 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 24 3/A611 2/A611 1/A611 146 147 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- R/A620 ALUM DK BRZ 26 11/A624 4/A624 -- 147
149A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 X/A620 ALUM DK BRZ 27 11/A624 4/A624 2/A624 149A 149B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 149B 149C D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 149C 150A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 T/A620 ALUM DK BRZ 29 11/A624 5/A624 2/A624 150A 150B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 150B 150C D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 150C 153A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 X/A620 ALUM DK BRZ 29 11/A624 1/A623 -- 153A 153B D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 153B 153C D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 153C 154 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- N/A620 ALUM DK BRZ 03 11/A624 5/A624 2/A624 154 155 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- R/A620 ALUM DK BRZ 10 11/A624 4/A624 2/A624 155
156A D2 ALUM 6' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 H/A620 ALUM DK BRZ 28 6/A622 5/A622 12/A622 BR, E 156A 156B D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 M/A620 ALUM DK BRZ 30 11/A624 5/A624 -- 156B 156C D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 M/A620 ALUM DK BRZ 30 11/A624 5/A624 -- 156C 157 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 31 3/A611 2/A611 1/A611 157
158A D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4 & 14, IR, E 158A 158B D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4 & 14, IR, E 158B 158C D3 STEEL 10' - 0" 9' - 4" 0' - 2" DK BRZ -- -- ST C1 19 7/A612 9/A613 -- NOTE 4 & 14, IR, E 158C 159A D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 32 8/A612 9/A612 8/A611 BR 159A 159B D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 32 8/A612 9/A612 8/A611 BR 159B 162 D1 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 33 1/A612 4/A612 1/A611 162 163 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 26 2/A612 5/A612 1/A611 163 164 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 34 3/A611 2/A611 1/A611 164
165A D2 WD 6' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 Q/A620 ALUM DK BRZ 35 11/A624 5/A624 -- 165A 165B D1 HM 3' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM DK BRZ 36 5/A611 11/A611 9/A611 BR 165B 167A -- -- 8' - 0" 7' - 0" 0' - 1 3/4" -- -- F2 HM PT-14 -- 12/A611 13/A611 1/A611 (SIM) FRAMED OPENING 167A 167B D2 ALUM 3' - 0" 7' - 0" 0' - 1 3/4" DK BRZ GL-2 K/A620 ALUM DK BRZ 37 6/A622 8/A622 12/A622 BR 167B 168 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 12 3/A612 6/A612 1/A611 168 169 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 38 3/A612 6/A612 -- 169 170 D2 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN GL-3 P/A620 ALUM DK BRZ 39 11/A624 4/A624 & 5/A624 -- 170 171 D1 HM 6' - 0" 7' - 0" 0' - 1 3/4" PT-12 -- F1 HM PT-12 16 5/A611 11/A611 9/A611 BR 171
172A D4 ALUM 13' - 8 1/2" 7' - 0" 0' - 1 3/4" DK BRZ GL-5 INTEGRAL ALUM DK BRZ 01 5/A613 4/A613 10/A613 SLIDING, MOTION DETECTION, IR, E 172A 172B D5 ALUM 13' - 7" 7' - 0 1/2" 0' - 2 1/2" DK BRZ GL-6 INTEGRAL ALUM DK BRZ 01 3/A613 2/A613 1/A613 SLIDING, MOTION DETECTION, BR, E 172B 173 -- -- 8' - 0" 7' - 0" 0' - 1 3/4" -- -- F2 HM PT-14 -- 12/A611 13/A611 1/A611 (SIM) FRAMED OPENING 173 176 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 176 178 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 21 3/A611 2/A611 -- 178 180 D1 WD 3' - 0" 7' - 0" 0' - 1 3/4" STAIN -- F1 HM PT-14 11 3/A611 2/A611 1/A611 180
SCALE: 1/4" = 1'-0"
DOOR FRAME ELEVATIONS
DOOR SCHEDULE NOTES
1 REFER TO EXTERIOR FINISH SCHEDULE, A201 FOR BASIS OF DESIGN FOR BLAST RESISTANT DOOR
ASSEMBLIES AND STOREFRONT SYSTEMS.
2 REFER TO DOOR ELEVATIONS FOR GLAZING LOCATIONS
3 DK BRZ IS ANODIZED DARK BRONZE FINISH, AA-M10 C22 A34
4 IMPACT RATED OH DOOR. MIN. 20 GA. SLATS; REFER TO SPEC. SECTION 08 33 23 AND ELECTRICAL 5 REFER TO FINISH SCHEDULE A600 FOR PAINT COLORS, PAINT NOTES, AND SPEC. SECTION 09 90 00 PAINTS
AND COATINGS.
6 REFER TO A620 FOR STOREFRONT ELEVATIONS, GLAZING TYPES AND LOCATIONS.
7 REFER TO SPEC SECTION 08 71 00 FOR HARDWARE REQUIREMENTS.
8 BR INDICATES BLAST RESISTANT - ALL EXTERIOR DOORS ARE TO BE BLAST RESISTANT AS REQUIRED BY
UFC 4-010-01, DoD MINIMUM ANTI TERRORISM STANDARDS FOR BUILDINGS, LATEST EDITION.
9 IR INDICATES IMPACT RESISTANT - DOORS NOT REQUIRED TO BE BLAST RESISTANT PER UFC 4-010-01, DoD
MINIMUM ANTI TERRORISM STANDARDS FOR BUILDINGS, LATEST EDITION ARE REQUIRED TO BE IMPACT RESISTANT IN ACCORDANCE WITH 2009 IBC DESIGN PRESSURE RATINGS AND LARGE MISSLE TESTS
10 BASIS OF DESIGN FOR AUTOMATIC SLIDING DOOR IS STANLEY, DURA-SHEILD HIGH SECURITY SERIES, BALLISTIC / BLAST RESISTANT AUTOMATIC SLIDING DOOR SYSTEMS, DUAL MOTOR DRIVE, WITH SU-100
MOTIOIN SENSOR, DARK BRONZE FINISH
11 BASIS OF DESIGN FOR INTERIOR STOREFRONT IS EFCO SERIES 401, COLOR - DK BRZ, FINISH - AA-M10 C22 A34
12 REFER TO SPECIFICATION SECTION 08 39 54 - BLAST RESISTANT DOORS, REFER TO SPECIFICATION SECTION 08 42 29.43 - IMPACT RATED SLIDING AUTOMATIC ENTRANCES, REFER TO SPECIFICATION
SECTION 08 42 29.53 - BLAST RESISTANT SLIDING AUTOMATIC ENTRANCES
13 E INDICATES ELECTRICAL CONNECTION IS REQUIRED. REFER TO ELECTRICAL.
14 ALL SURFACES OF STRUCTURAL STEEL PLATES, CHANNELS, COLUMNS AND ANGLES USED TO RE-INFORCE
OPENINGS FOR AT-FP SHALL BE FINISHED WITH COATING 1 (C1); REFER TO A201 EXTERIOR MATERIAL &
COLOR LEGEND, AND SPECIFICATION SECTION 09 97 13.00 40 STEEL COATINGS.
15 SEAL ALL SURFACES OF DOORS WITH PAINT OR STAIN, INCLUDING EDGES.
16 DOORS INDICATED TO BE STAINED TO BE IN ACCORDANCE WITH 2.2.8.6 ON A600
17 EXPOSED OR CONCEALED STEEL PLATES, ANGLES OR TUBES TO BE C1; REFER TO A201 & SPECIFICATION
SECTION 09 97 13.00 40 STEEL COATINGS.
SCALE: 1/4" = 1'-0"
DOOR ELEVATIONS
(2) 3'-0"
(2) 2'-6"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-0"
(2) 3'-6 1/2"
(2) 3'-7 1/8"
(2) 3'-6 1/2"
(2) 3'-7 1/8"
HOLLOW METAL DOOR FRAME;
REFER TO DOOR SCHEDULE
DOOR; REFER TO
DOOR SCHEDULE
TRANSITION STRIP (IF REQUIRED);
REFER TO DOOR SCHEDULE, FLOOR
FINISH PLAN, DETAILS & NOTES
EXISTING SLAB; REFER TO
STRUCTURAL FLOOR FINISH; REFER
FINISH SCHEDULE
5 3/4"
SEALANT; BOTH
SIDES , TYP.
DOOR; REFER TO
DOOR SCHEDULE
METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
GYPSUM BOARD
HOLLOW METAL DOOR FRAME;
REFER TO DOOR SCHEDULE
DOUBLE STUD AT JAMB;
EACH SIDE, TYP.
SOUND BATTS; REFER TO
PLAN(S) AND WALL TYPES
FOR LOCATION(S)
5 3/4"
2"
SOUND BATTS; REFER
TO PLAN(S) & WALL
TYPES FOR LOCATION(S)
SEALANT; BOTH
SIDES, TYP.
DOOR; REFER TO
DOOR SCHEDULE
METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
GYPSUM BOARD; ABUT
DOOR FRAME
HOLLOW METAL DOOR
FRAME; REFER TO
DOOR SCHEDULE
METAL STUD HEADER;
REFER TO STRUCTURAL
5 3/4"
4"
NEW/EXISTING BRICK
VENEER/STUD WALL; REFER TO
FLOOR PLAN AND WALL TYPES
AIR SPACE
STEEL LINTEL; REFER TO
STRUCTURAL
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
BACKER-ROD & SEALANT
DOOR; REFER TO
DOOR SCHEDULE
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT AND ATTACH
TO STEEL PLATE2" 5 3/4"
CMU LINTEL BLOCK;
REFER TO STRUCTURAL
FLUID APPLIED VAPOR BARRIER AT NEW CMU
WALL LOCATIONS. APPLY TO CONCEALED
EDGE OF CMU PRIOR TO INSTALLATION OF
STEEL PLATE AND/OR BRICK. REFER TO
EXTERIOR FINISH SCHEDULE.
SEALANT
STEEL TUBE; FINISH TO BE
C1; REFER TO EXTERIOR
MATERIAL & COLOR
SCHEDULE; REFER TO
STRUCTURAL
BOLT STEEL PLATE TO CMU;
REFER TO STRUCTURAL
STEEL PLATE; PAINT
EXPOSED SURFACES,
REFER TO STRUCTURAL
LAP FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
HEAD FLASHING, TYPE F; REFER TO
A620 FOR FLASHING TYPES SELF-ADHERING BITUTHANE
FLASHING WRAP AT OPENING;
REFER TO A625 FOR SEQUENCE
NEW/EXISTING BRICK VENEER/CMU
STUD WALL; REFER TO FLOOR
PLAN AND WALL TYPES
AIR SPACE
STEEL LINTEL; REFER TO
STRUCTURAL
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
BACKER-ROD & SEALANT
DOOR; REFER TO
DOOR SCHEDULE
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT AND ATTACH
TO STEEL PLATE
2 1/8" 8 5/8"
CMU LINTEL BLOCK(S);
REFER TO STRUCTURALFLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS. APPLY
TO CONCEALED EDGE OF CMU PRIOR
TO INSTALLATION OF STEEL PLATE
AND/OR BRICK. REFER TO EXTERIOR
FINISH SCHEDULE.
SEALANT
BOLT STEEL PLATE TO CMU;
REFER TO STRUCTURAL
LAP COAT OF FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
SELF-ADHERING BITUTHANE
FLASHING WRAP AT OPENING;
REFER TO A625 FOR SEQUENCE
STEEL TUBE; REFER TO
STRUCTURAL
BATT INSULATION
GYPSUM BOARD
CORNER BEAD
GYPSUM BOARD; ATTACH TO
TRACK/CHANNEL, ADHERE
TO STEEL PLATE AND
ABUT DOOR FRAME
STEEL PLATE; ATTACH TO
TUBE STEEL, REFER TO
STRUCTURAL
METAL CHANNEL
METAL STUD HEADER;
REFER TO STRUCTURAL
METAL TRACK; TRIM AT
TUBE STEEL
SEALANT; TYP.
DOOR, REFER TO
DOOR SCHEDULE
CMU/METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
METAL STUD HEADER;
REFER TO STRUCTURAL
GYPSUM BOARD
HOLLOW METAL DOOR
FRAME; FILL WITH GROUT,
REFER TO DOOR SCHEDULE
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
CORNER BEAD
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL) SOUND BATTS; REFER
TO PLAN(S) AND WALL
TYPES FOR LOCATION(S)
SEALANT; TYP.
5 3/4"
AIR SPACE
FLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS; APPLY
TO CONCEALED EDGE OF CMU PRIOR
TO INSTALLATION OF STEEL PLATE
AND/OR BRICK, REFER TO EXTERIOR
FINISH SCHEDULE
BACKER-ROD & SEALANT
DOOR; REFER TO
DOOR SCHEDULE
STEEL TUBE; FINISH
TO BE C1; REFER TO
EXTERIOR MATERIAL
& COLOR SCHEDULE;
REFER TO
STRUCTURAL
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT AND ATTACH
TO STEEL PLATE.
BRICK/CMU WALL;
REFER TO FLOOR
PLAN AND WALL TYPESREFER TO STRUCTURAL FOR
CMU REINFORCEMENT SIZE,
QUANTITY AND LOCATION(S)
STEEL PLATE; ATTACH TO
TUBE STEEL, PAINT, REFER
TO STRUCTURAL
BOLT STEEL PLATE TO CMU;
REFER TO STRUCTURAL
SEALANT
SELF-ADHERING BITUTHANE
FLASHING WRAP; REFER TO
A625 FOR SEQUENCE
2" 5 3/4"
AIR SPACE
FLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS; APPLY
TO CONCEALED EDGE OF CMU
PRIOR TO INSTALLATION OF STEEL
PLATE AND/OR BRICK, REFER TO
EXTERIOR FINISH SCHEDULE
BACKER-ROD &
SEALANT; TYP.
DOOR; REFER TO
DOOR SCHEDULE
STEEL TUBE; REFER TO
STRUCTURAL
HOLLOW METAL DOOR FRAME;
CONCEAL ANCHOR BOLT, FILL
WITH GROUT AND ATTACH TO
STEEL PLATE.
BATT INSULATION
BRICK/CMU/METAL STUD
WALL; REFER TO FLOOR
PLAN AND WALL TYPES
GYPSUM BOARD
CORNER BEAD
REFER TO STRUCTURAL
FOR CMU REINFORCEMENT
SIZE AND LOCATION(S)
GYPSUM BOARD; ATTACH TO
CHANNEL, ADHERE TO STEEL
PLATE AND ABUT FRAME
STEEL PLATE; ATTACH TO
TUBE STEEL, REFER TO
STRUCTURAL
METAL TRACK; ATTACH TO
SLAB, CONTINUE TO CORNER
METAL CHANNEL
BOLT STEEL PLATE TO CMU;
REFER TO STRUCTURAL
SEALANT; TYP.
SELF-ADHERING BITUTHANE
FLASHING WRAP AT
OPENING; REFER TO A625
FOR SEQUENCE
2" 8 3/4"
SEALANT; TYP.
DOOR; REFER TO
DOOR SCHEDULE
CMU/METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
SOUND BATTS; REFER TO
PLAN AND WALL TYPES
FOR LOCATIONS
DOUBLE STUDS AT JAMB;
EACH SIDE TYP.
GYPSUM BOARD
HOLLOW METAL DOOR
FRAME; FILL WITH GROUT,
REFER TO DOOR SCHEDULE
REFER TO STRUCTURAL FOR
CMU REINFORCEMENT SIZE,
QUANTITY AND LOCATION(S)
CORNER BEAD
5 3/4"
SEALANT, TYP.
HOLLOW METAL DOOR FRAME;
REFER TO DOOR SCHEDULE
DOOR; REFER TO
DOOR SCHEDULE
EXPANSION JOINT;
REFER TO STRUCTURAL
CONCRETE SIDEWALK;
REFER TO CIVIL
THRESHOLD; REFER TO
DOOR SCHEDULE AND
HARDWARE SPEC SECTION
08 71 00 FOR TYPE & SIZE
EXISTING SLAB; REFER TO
STRUCTURAL
2" 5 3/4"
HOLLOW METAL DOOR FRAME;
REFER TO DOOR SCHEDULE
DOOR; REFER TO
DOOR SCHEDULE
EXPANSION JOINT;
REFER TO STRUCTURAL
CONCRETE SIDEWALK;
REFER TO CIVIL
THRESHOLD; REFER TO
DOOR SCHEDULE AND
HARDWARE SPEC SECTION
08 71 00 FOR TYPE & SIZE
EXISTING SLAB; REFER TO
STRUCTURAL
2" 8 3/4" SOUND BATTS; REFER
TO PLAN(S) & WALL
TYPES FOR LOCATION(S)
SEALANT; BOTH
SIDES, TYP.
METAL STUD WALL;
REFER TO FLOOR
PLAN AND WALL TYPES
GYPSUM BOARD; ABUT
DOOR FRAME
HOLLOW METAL
CASING FRAME; REFER
TO DOOR SCHEDULE
METAL STUD HEADER;
REFER TO STRUCTURAL
4"
5 3/4"
SEALANT; BOTH
SIDES , TYP.
METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
GYPSUM BOARD
HOLLOW METAL DOOR FRAME;
REFER TO DOOR SCHEDULE
DOUBLE STUD AT JAMB;
EACH SIDE, TYP.
SOUND BATTS; REFER TO
PLAN(S) AND WALL TYPES
FOR LOCATION(S)
2"
5 3/4"
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A611
DO
OR
D
ET
AI
LS
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 3" = 1'-0"1 INTERIOR DOOR TRANSITION
SCALE: 3" = 1'-0"2 INTERIOR DOOR JAMB
SCALE: 3" = 1'-0"3 INTERIOR DOOR HEAD
SCALE: 3" = 1'-0"4 EXTERIOR DOOR HEAD (BR)
SCALE: 3" = 1'-0"5 EXTERIOR DOOR HEAD (BR)
SCALE: 3" = 1'-0"6 INTERIOR DOOR HEAD
SCALE: 3" = 1'-0"10 EXTERIOR DOOR JAMB (BR)
SCALE: 3" = 1'-0"11 EXTERIOR DOOR JAMB (BR)
SCALE: 3" = 1'-0"7 INTERIOR DOOR JAMB
SCALE: 3" = 1'-0"8 EXTERIOR DOOR THRESHOLD
SCALE: 3" = 1'-0"9 EXTERIOR DOOR THRESHOLD
SCALE: 3" = 1'-0"12 INTERIOR FRAMED OPENING HEAD
SCALE: 3" = 1'-0"13 INTERIOR FRAMED OPENING JAMB
SEALANT; BOTH SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
SOUND BATTS; REFER TO PLAN(S)
WALL TYPES FOR LOCATION(S)
GYPSUM BOARD
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT, ATTACH TO
CMU, REFER TO DOOR SCHEDULE
CMU/SHOTCRETE/STUD WALL;
REFER TO FLOOR PLANS AND
WALL TYPES
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
CORNER BEAD
STEEL ANGLE; REFER
TO STRUCTURAL
GYPSUM BOARD; ATTACH TO STUD,
ADHERE TO ANGLE AND ABUT DOOR FRAME
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
METAL STUD HEADER;
REFER TO STRUCTURAL
5 3/4"
SEALANT; BOTH
SIDES,TYP.
DOOR; REFER TO
DOOR SCHEDULE
SHOTCRETE; REFER TO
STRUCTURAL FOR
THICKNESS AND LOCATION(S)
SOUND BATTS; REFER TO
PLAN(S) WALL TYPES FOR
LOCATION(S)
METAL STUD HEADER;
REFER TO STRUCTURAL
GYPSUM BOARD; ATTACH TO STUD,
ADHERE TO ANGLE AND ABUT DOOR FRAME
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT, ATTACH TO
CMU, REFER TO DOOR SCHEDULE
CMU/SHOTCRETE/STUD WALL;
REFER TO FLOOR PLANS AND
WALL TYPES
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
CORNER BEADCORNER BEAD
GYPSUM BOARD
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
STEEL ANGLE;
REFER TO STRUCTURAL
5 3/4"
SEALANT; BOTH
SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
GYPSUM BOARD
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT, ATTACH TO
CMU, REFER TO DOOR SCHEDULE
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
CORNER BEADCORNER BEAD
GYPSUM BOARD
CMU/STUD WALL; REFER TO
FLOOR PLANS AND WALL TYPES
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
SOUND BATTS; REFER TO
PLAN(S) WALL TYPES FOR
LOCATION(S)
GYPSUM BOARD; ATTACH TO
STUD AND ABUT DOOR FRAME
5 3/4"
SEALANT; BOTH SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
SOUND BATTS; REFER TO PLAN(S)
WALL TYPES FOR LOCATION(S)
GYPSUM BOARD
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT, ATTACH TO
CMU, REFER TO DOOR SCHEDULE
NEW/EXISTING CMU WALL;
REFER TO FLOOR PLAN AND
WALL TYPES
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
CORNER BEAD
STEEL ANGLE; REFER TO
STRUCTURAL
5 3/4"
GYPSUM BOARD; ATTACH TO STUD,
ADHERE TO ANGLE AND ABUT DOOR FRAME
SEALANT; BOTH
SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
SHOTCRETE; REFER TO
STRUCTURAL FOR THICKNESS
AND LOCATION(S)
SOUND BATTS; REFER TO PLAN(S)
WALL TYPES FOR LOCATION(S)
GYPSUM BOARD
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT, ATTACH TO
CMU, REFER TO DOOR SCHEDULE
CMU/SHOTCRETE/STUD WALL;
REFER TO FLOOR PLAN AND
WALL TYPES
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
GYPSUM BOARD
CORNER BEADCORNER BEAD
STEEL ANGLE; REFER
TO STRUCTURAL
GYPSUM BOARD; ATTACH STUD,
ADHERE TO ANGLE AND ABUT
DOOR FRAME
5 3/4"
SEALANT; BOTH
SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
SOUND BATTS; REFER TO
PLAN(S) WALL TYPES FOR
LOCATION(S)
GYPSUM BOARD
HOLLOW METAL DOOR FRAME,
FILL WITH GROUT, ATTACH TO
CMU, REFER TO DOOR SCHEDULE
CMU/STUD WALL; REFER
TO FLOOR PLANS AND
WALL TYPES
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
GYPSUM BOARD
CORNER BEADCORNER BEAD
GYPSUM BOARD; ATTACH TO
STUD AND ABUT DOOR FRAME
5 3/4"
STEEL BEAM, REFER TO
STRUCTURAL.
ROLL-UP DOOR MOTOR
STEEL PLATE, REFER TO
STRUCTURAL.
ROLL-UP DOOR HOOD
BREAK METAL TRIM; PRE-FINISHED
TO MATCH STOREFRONT SYSTEM
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
LAP FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
CMU, REFER TO STRUCTURAL
FOR REINFORCING AND LINTEL
INFORMATION
INSULATED METAL SOFFIT
PANELS; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
ROLL-UP OVERHEAD DOOR;
REFER TO DOOR SCHEDULE
SELF-ADHERING BITUTHANE
FLASHING WRAP; REFER TO
A625 FOR SEQUENCE
DRIP EDGE; PRE-FINISHED TO
MATCH STOREFRONT SYSTEM
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
CMU INFILL FOR DOOR
HOOD ATTACHMENT
EXISTING BRICK VENEER
AIR SPACE
EXISTING ANGLE
SEALANT; BOTH
SIDES, TYP.
EXISTING BRICK BEYOND
DOOR, REFER TO
DOOR SCHEDULE
EXISTING CMU
WALL
HOLLOW METAL DOOR
FRAME; FILL WITH GROUT,
ATTACH TO CMU, REFER
TO DOOR SCHEDULE
2" 5 3/4"
EXISTING CMU
BOND BEAM
EXISTING VAPOR
BARRIER (FIELD VERIFY
LOCATION AND MATERIAL) EXISTING BRICK
VENEER
AIR SPACE
SEALANT; BOTH
SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
EXISTING CMU
WALL
HOLLOW METAL DOOR FRAME;
FILL WITH GROUT ATTACH TO
CMU, REFER TO DOOR SCHEDULE
2" 5 3/4"
EXISTING VAPOR BARRIER
(FIELD VERIFY LOCATION
AND MATERIAL)
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A612
DO
OR
D
ET
AI
LS
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 3" = 1'-0"1 INTERIOR DOOR HEAD
SCALE: 3" = 1'-0"2 INTERIOR DOOR HEAD
SCALE: 3" = 1'-0"3 INTERIOR DOOR HEAD
SCALE: 3" = 1'-0"4 INTERIOR DOOR JAMB
SCALE: 3" = 1'-0"5 INTERIOR DOOR JAMB
SCALE: 3" = 1'-0"6 INTERIOR DOOR JAMB
SCALE: 3" = 1'-0"7 EXTERIOR DOOR HEAD (ROLL-UP DOOR)
SCALE: 3" = 1'-0"8 EXTERIOR DOOR HEAD
SCALE: 3" = 1'-0"9 EXTERIOR DOOR JAMB
ALUMINUM STOREFRONT
SYSTEM FRAME
THRESHOLD
6"
STEEL PLATE; REFER
TO STRUCTURE
WELD STEEL PLATE TO STEEL
TUBE; REFER TO STRUCTURAL
GYPSUM WALLBOARD
ALUMINUM STOREFRONT
SYSTEM FRAME
DOOR PANEL
THRESHOLD BELOW
STEEL TUBE; REFER TO
STRUCTURE
SEALANT; BOTH SIDES,
TYP.
METAL STUD WALL; REFER
TO PLAN(S) AND WALL TYPES
METAL CHANNEL
SEALANT, TYP.
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
BACKER-ROD & SEALANT
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
BRICK VENEER
BRICK VENEER/CMU/STUD
WALL; REFER TO FLOOR
PLAN AND WALL TYPES
BATT INSULATION
CORNER BEAD
STEEL TUBE; REFER TO
STRUCTURAL
METAL CHANNEL
GYPSUM BOARD; ATTACH TO METAL
CHANNEL, ADHERE TO STEEL PLATE
AND ABUT STOREFRONT FRAME
STEEL PLATE; ATTACH TO TUBE
STEEL; REFER TO STRUCTURAL
FLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS, APPLY TO
CONCEALED EDGE OF CMU PRIOR TO
INSTALLATION OF STEEL PLATE, REFER
TO EXTERIOR FINISH SCHEDULE4
1/ 2"
2"
SELF-ADHERING BITUTHANE
FLASHING WRAP; REFER TO
A625 FOR SEQUENCING
5 3/4"
SEALANT; BOTH SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
CMU/METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
GYPSUM BOARD; ATTACH TO CHANNEL,
ADHERE TO STEEL PLATE AND ABUT
DOOR FRAME
HOLLOW METAL DOOR
FRAME; FILL WITH
GROUT, REFER TO
DOOR SCHEDULE
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
METAL CHANNEL
SOUND BATTS; REFER TO
PLAN(S) AND WALL TYPES
FOR LOCATION(S)
STEEL TUBE; REFER
TO STRUCTURAL
CORNER BEAD
2"
SEALANT; BOTH SIDES, TYP.
DOOR, REFER TO
DOOR SCHEDULE
CMU/METAL STUD WALL;
REFER TO FLOOR PLAN
AND WALL TYPES
STUD HEADER; REFER
TO STRUCTURAL
GYPSUM BOARD
HOLLOW METAL DOOR
FRAME; CONCEAL
FASTENER, FILL WITH
GROUT, REFER TO DOOR
SCHEDULE
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
METAL CHANNEL
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL)
SOUND BATTS;
REFER TO PLAN(S)
AND WALL TYPES
FOR LOCATION(S)
5 3/4"
STEEL TUBE; REFER
TO STRUCTURAL
CORNER BEAD
4"
METAL TRACK; TRIM AT TUBE STEEL
EXTERIORINTERIOR
5/
8"
8 7/8" 6"
DIRECTIONAL MOTION
SENSOR BY SLIDING
DOOR MANUFACTURER
DIRECTIONAL MOTION
SENSOR BY SLIDING DOOR
MANUFACTURER
ACCESS COVER
GYPSUM BOARD
BATT INSULATION
STEEL PLATE; REFER
TO STRUCTURAL
METAL STUD WALL; REFER TO
FLOOR PLAN AND WALL TYPES
SEALANT; BOTH
SIDES, TYP.
CLOSURE STRIP BY SLIDING
DOOR MANUFACTURER
DIRECTIONAL MOTION SENSOR BY
SLIDING DOOR MANUFACTURER
ACCESS COVER
INTERIOR EXTERIOR
AUTOMATIC SLIDING DOOR. REFER
TO A201 FOR BASIS OF DESIGN
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
BREAK METAL TRIM; PRE-FINISH TO
MATCH STOREFRONT SYSTEM
GYPSUM BOARD
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
BACKER-ROD AND SEALANT
BATT INSULATION
CORNER BEAD
STEEL PLATE; REFER
TO STRUCTURAL
STEEL TUBE; REFER TO
STRUCTURAL
GYPSUM BOARD; ATTACH TO
CHANNEL, ADHERE TO STEEL PLATE
AND ABUT STOREFRONT FRAME
METAL TRACK;
TRIM AT TUBE STEEL
FLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS, APPLY
TO CONCEALED EDGE OF CMU PRIOR
TO INSTALLATION OF STEEL PLATE,
REFER TO EXTERIOR FINISH SCHEDULE
REFER TO STRUCTURAL FOR
REINFORCEMENT SIZE AND LOCATION(S)
LAP COAT OF FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
STUD FURRING; REFER
TO WALL TYPES
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
DIRECTIONAL MOTION SENSOR BY
SLIDING DOOR MANUFACTURER
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
4 1/2" 2"
BREAK METAL TRIM; PRE-FINISHED TO
MATCH STOREFRONT SYSTEM WITH
PRE-FORMED DRIP EDGE
GYPSUM BOARD
CONCRETE BEAM;
REFER TO STRUCTURAL
BACKER-ROD AND SEALANT
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
BATT INSULATION
GLAZING; REFER TO ELEVATIONS
AND GLAZING SCHEDULE
CORNER BEAD
STEEL PLATE; REFER
TO STRUCTURAL
STEEL TUBE; REFER TO
STRUCTURAL
GYPSUM BOARD; ATTACH TO
CHANNEL, ADHERE TO STEEL PLATE
AND ABUT STOREFRONT FRAME
METAL TRACK; TRIM AT TUBE STEEL
METAL HEADER; REFER
TO STRUCTURAL
5" 2"
METAL CHANNEL
SEALANT, TYP.
REFER TO STRUCTURAL FOR
REINFORCEMENT SIZE AND LOCATION(S)
STEEL CHANNEL; REFER
TO STRUCTURAL
STEEL CHANNEL; REFER
TO STRUCTURAL
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
CLOSURE STRIP BY
STOREFRONT MANUFACTURER
HEAD FLASHING, TYPE F; REFER TO A620
FOR FLASHING TYPES
LAP COAT OF FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
AIR SPACE
FLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS; APPLY
TO CONCEALED EDGE OF CMU
PRIOR TO INSTALLATION OF STEEL
PLATE AND/OR BRICK, REFER TO
EXTERIOR FINISH SCHEDULE
SEALANT; TYP.
STEEL TUBE; REFER TO
STRUCTURAL
BATT INSULATION
BRICK/CMU/METAL STUD WALL; REFER
TO FLOOR PLAN AND WALL TYPES
GYPSUM BOARDREFER TO STRUCTURAL
FOR CMU REINFORCEMENT
SIZE AND LOCATION(S)
STEEL PLATE; ATTACH TO TUBE
STEEL, REFER TO STRUCTURAL
BRICK VENEER/CMU/STUD
WALL; REFER TO WALL TYPES
METAL CHANNEL
SELF-ADHERING BITUTHANE
FLASHING WRAP AT OPENING;
REFER TO A625 FOR SEQUENCING
OVERHEAD DOOR; REFER
TO DOOR SCHEDULE
STEEL DOOR TRACK BY
OVERHEAD DOOR
MANUFACTURER; C2
COATING
ALUMINUM STOREFRONT
SYSTEM FRAME
TAPERED EXTRUSION
THRESHOLD
4 1/2"
1/ 2"
6"
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A613
DO
OR
D
ET
AI
LS
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 3" = 1'-0"1 DOOR SILL (BR)
SCALE: 3" = 1'-0"2 INTERIOR DOOR JAMB (BR)
SCALE: 3" = 1'-0"4 EXTERIOR DOOR JAMB (IR)
SCALE: 3" = 1'-0"6 INTERIOR DOOR JAMB (BR)
SCALE: 3" = 1'-0"7 INTERIOR DOOR HEAD (BR)
SCALE: 3" = 1'-0"3 INTERIOR DOOR HEAD (BR)
SCALE: 3" = 1'-0"5 EXTERIOR DOOR HEAD (IR)
SCALE: 3" = 1'-0"8 EXTERIOR STOREFRONT (HEAD @ TRANSOM) (BR)
SCALE: 3" = 1'-0"9 EXTERIOR DOOR JAMB
SCALE: 3" = 1'-0"10 DOOR SILL (IR)
6'-11"
6'- 8"
2'- 8"
2'- 4"
4'- 4"
GL-1 GL-1
GL-1 GL-1
EQEQ
9'- 4"
1/A622 3/A
2 3/A621
6/A621
7/A
4/A
1/A
5/A
3'- 0"
4'- 4"
3'-0"
7'- 4"
GL-2
6/A624
3/A
/A
6'-11"
2'- 4"
7'- 0"
EQ EQ
9'- 4"
GL-1 GL-1
1/A622 3/A621
4/A
1/A
9'- 4"
4'-2"
2'- 4"
4'- 4"
2'- 8"
GL-1
GL-1
GL-1
3/A
3/A621
4/A
8/A
10'-3"
9'- 4"
2'- 8"
4'- 4"
2'- 4"
EQ EQ EQ
GL-1GL-1 GL-1
GL-1GL-1 GL-1
GL-1GL-1 GL-1
1/A622
3/A
8/A
/A
10/A621
7/A
3/A621
9'- 4"
10'-3"
7'- 0"
2'- 8"
4'- 4"
2'- 4"
2'-1 1/2" 6'-0" 2'-1 1/2"
GL-1
GL-1
GL-1
GL-1
GL-1
GL-1GL-12/A622
6/A
3/A
5/A622
7/A
/A
10/A621
9/A621
8/A
3/A621
6'-11"
9'- 4"
2'- 4"
4'- 4"
2'- 8"
3'-3 1/2" 3'-0"
7'- 0"
GL-1
GL-1
GL-1 GL-1
2/A622
5/A622
3/A
2 6/A
9/A622 8/A622
4/A
7/A
3/A621
6/A621
11/A622 10/A622
8/A
GL-4 GL-4
GL-3
GL-4
GL-3
GL-3GL-3
9'- 4"
2'- 4"
4'- 4"
2'- 8"
10'-0" 2'-0" 6'-0" 2'-0"
7'- 0"
/A
7/A
5/A624
9/A624
2/A
1/A
5/A623
6/A
GL-4
GL-4 GL-4
GL-3 GL-3
GL-3 GL-3
2'- 4"
4'- 4"
2'- 8"
9'- 4"
8'-0" 2'-6" 3'-0" 2'-6"
7'- 0"
6/A624
1/A
2/A
7/A
/A
9/A624
/A
5/A624
5'-6"
9'- 4"
2'-0 3/4"3'-0"
2'- 8"
4'- 4"
2'- 4"
GL-4 GL-4
GL-3
7'- 0"
GL-3
6/A624
/A
1/A
2/A
4/A624
7/A
/A
9/A624
5/A624
16'-0"
9'- 4"
6'-0"
2'- 4"
4'- 4"
2'- 8"
EQ EQ EQ EQ
7'- 0"
GL-4GL-4GL-4 GL-4GL-4
GL-3GL-3
GL-3GL-3
GL-3GL-3 GL-3GL-3
6/A624
8/A624
5/A624
/A
/A
2/A
7/A
9/A624
1/A
9'- 4"
2'- 8"
4'- 4"
2'- 4"
GL-3GL-3GL-3GL-3 GL-3 GL-3 GL-3
GL-4GL-4GL-4GL-4 GL-4 GL-4 GL-4
GL-3GL-3GL-3GL-3 GL-3 GL-3 GL-3
/A
7/A
1/A
8/A624
SPECIAL JAMB SHAPE; REFER TO
STOREFRONT MANUFACTURER
28'-0"
9'- 4"
6'-0"
2'- 4"
4'- 4"
2'- 8"
7'- 0"
EQEQEQ EQ EQ EQ
GL-4GL-4GL-4GL-4 GL-4GL-4GL-4
GL-3GL-3GL-3 GL-3GL-3GL-3
GL-3GL-3GL-3 GL-3GL-3GL-3
6/A6248/A6245/A624
9/A624
/A
2/A
1/A
7/A
/A
21'-0"
9'- 4"
2'- 4"
4'- 4"
2'- 8"
EQEQEQEQEQEQ
GL-4GL-4GL-4 GL-4 GL-4 GL-4
GL-3GL-3GL-3 GL-3 GL-3 GL-3
GL-3GL-3GL-3 GL-3 GL-3 GL-3
6/A6248/A624
7/A
1/A
/A
9'- 4"
10'-5 1/4"
EQ EQ EQ
2'- 4"
4'- 4"
2'- 8"
GL-3
GL-4
GL-3
GL-3
GL-4
GL-3
GL-3
GL-4
GL-3
6/A6248/A624
7/A
1/A
/A
GL-4
6'-3 1/2"
9'- 4"
6'-0"7'- 0"
2'- 4"
4/A62411 /A
/A
2/A
6/A
1/A623
GLAZING TYPES
MARK
GL-1 BRONZE, BLAST RESISTANT, LOW E, LAMINATED,
INSULATED GLAZING UNITS
GL-2
GL-3
GL-4
GL-5
DESCRIPTION
REFER TO SPEC SECTION 08 81 00
SIZE
1 5/16"
GL-6
GL-7 MIRROR
9/16"
1/4" 1/4" 9/16"
9/16"
BRONZE, BLAST RESISTANT, LOW E, LAMINATED
GLAZING UNITS
TEMPERED GLASS
CLEAR GLASS
BRONZE, LOW E, LAMINATED, WINDBORNE DEBRIS
IMPACT RATED GLAZING UNITS
CLEAR, BLAST RESISTANT, LAMINATED GLAZING UNITS
9'- 4"
2'- 4"
7'- 0"
3'-5"
GL-1
6/A
8/A622
4/A
10/A622
9'- 4"
2'- 8"
4'- 4"
2'- 4"
5'-9"
EQ EQ
GL-1 GL-1
GL-1 GL-1
GL-1 GL-1
1/A622
3/A
10/A621
9/A621
8/A
7/A
/A
3'-9 1/2"
22'-0"4'-5 3/8" 4'-4 1/2" 4'-4 1/2" 4'-4 1/2" 4'-5 3/8"
3'-9 1/2
SPECIAL JAMB SHAPE; REFER TO
STOREFRONT MANUFACTURER
9'- 4"
2'- 8"
4'- 4"
2'- 4"
10'-0"
2'-0"3'-0"2'-6"2'-6"
7'- 0"
GL-4GL-4GL-4 GL-4
GL-3GL-3 GL-3
GL-3GL-3 GL-3
6/A624
5/A624
8/A624
1/A
2/A
9/A624
/A
/A
7/A
GL-1 GL-1 GL-1 GL-1GL-1
1/A622
23'-11 3/8"
4'-6 1/8" 2'-6" 5'-7 1/8" 5'-8 1/8" 5'-8 1/8" 4'-
8" 4/A623
2/A
3/A
GL-1 GL-1
GL-1GL-1
GL-1
1/A622
23'-3 3/4"
5'-3" 5'-4 1/2" 5'-0 1/2" 2'-7 1/2" 5'-0 1/4"
2'- 4"
1'- 2"
1'- 2"
4'- 8"
4/A623
3/A
2/A
LEGEND
SYMBOL
SECTION MARK @ STOREFRONT
DESCRIPTION
1/A600
9'- 4"
2'- 4"
7'- 0"
3'-3 1/2" 3'-0"
4/A624
6/A624
/A
/A
2/A
5" M
IN
5"
STEP FLASHING
TYPE A
WALL TO ROOF FLASHING
TYPE B
6" M
IN
4"
1/ 2"
THROUGH WALL FLASHING
TYPE C
3"MIN.
3/ 4"
EAVE FLASHING
TYPE D
3/4" OVERHANG
1/4" DRIP EDGE
3"MIN.
3/
4" 3/4" OVERHANG
1/4" DRIP EDGE
RAKE FLASHING
TYPE E
4"
SIZE TO FIT
1/4" DRIP EDGE
HEAD FLASHING
TYPE F
VA
RI
ES
SIZE TO FIT
1/ 2"
3" (+/-) VARIES
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A620
ST
OR
EF
RO
NT
E
LE
VA
TI
ON
S N
OT
ES
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE A
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE C
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE B
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE D
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE G
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE H
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE L
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE M
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE N
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE P
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE Q
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE S
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE T
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE U
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE V
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE X
STOREFRONT & WINDOW NOTES
1 GLAZING SPECIFIED IN SECTION 08 81 00
2 BASIS OF DESIGN FOR BLAST RESISTANT STOREFRONT & WINDOWS - EFCO
S526 (T)
3 BASIS OF DESIGN FOR INTERIOR STOREFRONT & WINDOWS - EFCO S401
4 EXTERIOR ENTRANCE DOOR, BASIS OF DESIGN - EFCO D300, MEDIUM STILE
5 INTERIOR ENTRANCES IN STOREFRONT TO BE WOOD.
6 ALL SURFACES OF STRUCTURAL STEEL PLATES, CHANNELS, COLUMNS AND
ANGLES USED TO RE-INFORCE OPENINGS FOR AT-FP SHALL BE FINISHED
WITH COATING 1 (C1); REFER TO A201 EXTERIOR MATERIAL & COLOR
LEGEND, AND SPECIFICATION SECTION 09 97 13.00 40 STEEL COATINGS.
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE K
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE J
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE S PLAN
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE W
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE Z
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE Y
(EXTERIOR-BR)
SCALE: 1/4" = 1'-0"
STOREFRONT TYPE R
SCALE: 6" = 1'-0"
FLASHING TYPES
NEW ROWLOCK SILL
SEALANT
END DAMN; SEAL TO ADJACENT BRICK
BRICK/CMU/METAL STUD WALL; REFER
TO FLOOR PLAN AND WALL TYPES
GYPSUM BOARD
STEEL TUBE - REFER
TO STRUCTURAL
SEALANT ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
BATT INSULATION
EXISTING CMU
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
SOLID SURFACE WINDOW STOOL;
ADHERE TO STEEL PLATE & ATTACH TO
METAL STUD; PLUG ATTACHMENT HOLES,
REFER TO COLOR SCHEDULE
EXISTING BRICK VENEER
METAL CHANNEL; TRIM
AT TUBE STEEL
METAL CHANNEL
5" 2"
ROPE WEEPS @ 6 INCHES O.C.;
DO NOT SEAL ABOVE FLASHING
THROUGH WALL FLASHING; REFER
TO SPEC SECTION XX.XX.XX
STEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
SEALANT
CMU LINTEL BLOCK;
REFER TO STRUCTURAL
FLUID APPLIED VAPOR BARRIER AT NEW
CMU LOCATIONS, EXTEND OVER EXISTING
CMU IF POSSIBLE; APPLY TO CONCEALED
EDGE OF CMU PRIOR TO INSTALLATION OF
STEEL PLATE; REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
SILL FLASHING
GYPSUM BOARD
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
BATT INSULATION
CORNER BEAD
STEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
STEEL TUBE; REFER TO
STRUCTURAL
GYPSUM BOARD; ATTACH TO
CHANNEL, ADHERE TO STEEL PLATE
AND ABUT STOREFRONT FRAME
METAL TRACK; TRIM AT TUBE STEEL
METAL HEADER; REFER
TO STRUCTURAL
METAL CHANNEL
SEALANT, TYP.
BREAK METAL TRIM; PRE-FINISHED
TO MATCH STOREFRONT SYSTEM
LAP FLUID APPLIED VAPOR BARRIER
OVER METAL FLASHING
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
BACKER-ROD AND SEALANT
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
SELF-ADHERING BITUTHANE FLASHING
WRAP, REFER TO A625 FOR SEQUENCE
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
CLOSURE STRIP BY STOREFRONT
MANUFACTURER
5" 2"
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
SEALANT, TYP.
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
GLAZING; REFER TO
STOREFRONT ELEVATIONS
& GLAZING SCHEDULE
BACKER-ROD & SEALANT
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
EXISTING BRICK VENEER
BRICK/CMU/METAL STUD; REFER
TO FLOOR PLAN AND WALL TYPES
BATT INSULATION
CORNER BEAD
EXISTING CMU
STEEL TUBE; REFER TO
STRUCTURALSTEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
METAL CHANNEL
2" 5"
GYPSUM BOARD; ATTACH TO METAL
CHANNEL, ADHERE TO STEEL PLATE
AND ABUT STOREFRONT FRAME
FLUID APPLIED VAPOR BARRIER, APPLY TO
CONCEALED EDGES OF EXISTING CMU, IF
POSSIBLE, PRIOR TO INSTALLATION OF
STEEL TUBE COLUMN, REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
CLOSURE STRIP BY
STOREFRONT MANUFACTURER
CMU LINTEL BLOCK; REFER
TO STRUCTURAL
NEW ROWLOCK SILL
SEALANT
END DAMN; SEAL TO ADJACENT BRICK
METAL STUDS; ALIGN TOP TRACK
WITH TOP OF STEEL PLATE
GYPSUM BOARD
STEEL PLATE, WELD TO STEEL
ANGLE; REFER TO STRUCTURAL
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
BATT INSULATION
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
EXISTING BRICK VENEER
EXISTING CMU
STEEL ANGLE; REFER
TO STRUCTURAL
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
SOLID SURFACE WINDOW STOOL;
ADHERE TO STEEL PLATE & ATTACH TO
METAL STUD; PLUG ATTACHMENT
HOLES. REFER TO COLOR SCHEDULE
THROUGH WALL FLASHING; REFER
TO SPEC SECTION XX.XX.XX
SEALANT
5" 2"
BRICK/CMU/SHOTCRETE WALL; REFER
TO FLOOR PLAN AND WALL TYPES
SEALANT
ROPE WEEP @ 6 INCHES O.C.,
DO NOT SEAL ABOVE FLASHING
FLUID APPLIED VAPOR BARRIER AT NEW CMU
LOCATIONS, EXTEND OVER EXISTING CMU IF
POSSIBLE; APPLY TO CONCEALED EDGE OF
CMU PRIOR TO INSTALLATION OF STEEL
PLATE; REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
SILL FLASHING
GYPSUM BOARD; ADHERE TO STEEL
PLATE, ATTACH TO METAL STUD
AND ABUT STOREFRONT SYSTEM
SEALANT, TYP.
ALUMINUM STOREFRONT
SYSTEM JAMB; ATTACH TO
STEEL PLATE
GLAZING; REFER TO
GLAZING SCHEDULE
BACKER-ROD & SEALANT
ROW-LOCK BRICK SILL
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
EXISTING BRICK VENEER
BRICK/CMU/SHOTCRETE/METAL
STUD WALL; REFER TO FLOOR
PLAN AND WALL TYPES
BATT INSULATION
CORNER BEAD
EXISTING CMU
SHOTCRETE; REFER TO
STRUCTURAL FOR THICKNESS
AND LOCATION(S)
STEEL ANGLE - REFER TO
STRUCTURAL
STEEL PLATE, WELD TO STEEL
ANGLE; REFER TO STRUCTURAL
FLUID APPLIED VAPOR BARRIER, APPLY TO
CONCEALED EDGES OF EXISTING CMU, IF
POSSIBLE, PRIOR TO INSTALLATION OF
STEEL TUBE COLUMN, REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
SELF-ADHERING BITUTHANE FLASHING WRAP;
REFER TO A625 FOR SEQUENCING
CLOSURE STRIP BY
STOREFRONT MANUFACTURER 2"
5"
BREAK METAL TRIM; PRE-FINISHED TO
MATCH STOREFRONT SYSTEM
LAP FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
METAL STUD/SHOTCRETE/CMU
WALL; REFER TO FLOOR PLAN
AND WALL TYPES
GYPSUM BOARD
CMU LINTEL BLOCK(S);
REFER TO STRUCTURAL
BACKER-ROD AND SEALANT
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
BATT INSULATION
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
CORNER BEAD
STEEL PLATE, WELD TO STEEL
ANGLE; REFER TO STRUCTURAL
STEEL ANGLE; REFER
TO STRUCTURAL
GYPSUM BOARD; ATTACH TO METAL
STUD, ADHERE TO STEEL PLATE AND
ABUT STOREFRONT FRAME
5" 2"
SELF-ADHERING BITUTHANE FLASHING
WRAP, REFER TO A625 FOR SEQUENCE
REFER TO STRUCTURAL FOR
REINFORCEMENT SIZE AND LOCATION(S)
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
CLOSURE STRIP BY STOREFRONT
MANUFACTURERGLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO SLAB
SEALANT
SILL PLATE
BRICK VENEER BEYOND
EXPANSION JOINT;
REFER TO STRUCTURAL
CONCRETE SIDEWALK;
REFER TO CIVIL DWGS.
EXISTING CONCRETE SLAB;
REFER TO STRUCTURAL
5" 2"
METAL STUD FRAMING
GLAZING; REFER TO
STOREFRONT ELEVATIONS
& GLAZING SCHEDULE
SEALANT, TYP.
STEEL BEAM - REFER TO
STRUCTURAL
GYPSUM BOARD; ADHERE
TO STEEL PLATE AND ABUT
STOREFRONT FRAME
METAL STUD; REFER TO FLOOR
PLAN AND WALL TYPES
BATT INSULATION
STEEL PLATE, WELD TO
STEEL BEAM; REFER TO
STRUCTURAL
GYPSUM BOARD
CORNER BEAD BREAK METAL TRIM; PRE-FINISHED
TO MATCH STOREFRONT SYSTEM
LAP FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
BACKER-ROD AND SEALANT
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE
SELF-ADHERING BITUTHANE
FLASHING WRAP, REFER TO A625
FOR SEQUENCE
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
CLOSURE STRIP BY STOREFRONT
MANUFACTURER
5" 2"
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
GYPSUM BOARD; ATTACH TO
METAL STUD, ADHERE TO STEEL
PLATE, ABUT STOREFRONT FRAME
STEEL TUBE COLUMN;
REFER TO STRUCTURAL
SEALANT, TYP.
ALUMINUM STOREFRONT
SYSTEM FRAME; ATTACH TO
STEEL PLATE
GLAZING; REFER TO
STOREFRONT ELEVATIONS
& GLAZING SCHEDULE
CLOSURE STRIP BY
STOREFRONT MANUFACTURER
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
EXISTING BRICK VENEER
BRICK/CMU/METAL STUD WALL;
REFER TO FLOOR PLAN(S) AND
WALL TYPES
BATT INSULATION
CORNER BEAD
EXISTING CMU
5" 2"
STEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
FLUID APPLIED VAPOR BARRIER, APPLY
TO CONCEALED EDGES OF EXISTING CMU,
IF POSSIBLE, PRIOR TO INSTALLATION OF
STEEL TUBE COLUMN, REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
BACKER-ROD & SEALANT
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
BREAK METAL TRIM; PRE-FINISHED
TO MATCH STOREFRONT SYSTEM
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL
SEALANT, TYP.
BREAK METAL TRIM; PRE-FINISHED
TO MATCH STOREFRONT SYSTEM
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
WRAP COLUMN WITH SELF-
ADHERING BITUTHANE FLASHING
WRAP PRIOR TO INSTALLING
BREAK METAL TRIM
SEALANT, TYP.
EXTERIOR
INTERIOR
STEEL PLATE; BOLT TO STEEL
TUBE; REFER TO STRUCTURAL
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
FACE OF BRICK
2"
3" 3"
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A621
EX
TE
RI
OR
S
TO
RE
FR
ON
T
DE
TA
IL
S
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
141SCALE: 3" = 1'-0"1 EXTERIOR STOREFRONT SILL (BR)
SCALE: 3" = 1'-0"4 EXTERIOR STOREFRONT HEAD (BR)
SCALE: 3" = 1'-0"3 EXTERIOR STOREFRONT JAMB (BR)
SCALE: 3" = 1'-0"5 EXTERIOR STOREFRONT SILL (BR)
SCALE: 3" = 1'-0"6 EXTERIOR STOREFRONT JAMB (BR)
SCALE: 3" = 1'-0"7 EXTERIOR STOREFRONT HEAD (BR)
SCALE: 3" = 1'-0"8 EXTERIOR STOREFRONT SILL
SCALE: 3" = 1'-0"11 EXTERIOR STOREFRONT HEAD (BR)
SCALE: 3" = 1'-0"9 EXTERIOR STOREFRONT JAMB (BR)
SCALE: 3" = 1'-0"10 EXTERIOR STOREFRONT JAMB (BR)
2 1/2"
5"
ALUMINUM STOREFRONT
SYSTEM FRAME
GLAZING; REFER TO ELEVATIONS
AND GLAZING SCHEDULE
5"
2 1/2" 7/8"
ALUMINUM STOREFRONT
SYSTEM FRAME
GLAZING; REFER TO ELEVATIONS
AND GLAZING SCHEDULE
GLAZING; REFER TO ELEVATIONS
AND GLAZING SCHEDULE
ALUMINUM STOREFRONT
SYSTEM FRAME
5"
1/
2"
DOOR; REFER TO
DOOR SCHEDULE
ALUMINUM STOREFRONT
SYSTEM FRAME
GLAZING; REFER TO ELEVATIONS
AND GLAZING SCHEDULE
2 1/2"
5"
GLAZING; REFER TO ELEVATIONS
AND GLAZING SCHEDULE
ALUMINUM STOREFRONT
SYSTEM FRAME
DOOR; REFER TO
DOOR SCHEDULE
1/
2" 5"
SEALANT, TYP.
STEEL TUBE; REFER
TO STRUCTURAL
METAL STUD
BATT INSULATION
GYPSUM BOARD; ADHERE TO STEEL
PLATE, ATTACH TO METAL STUD
AND ABUT STOREFRONT FRAME
STEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
CORNER BEAD
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
BREAK METAL TRIM; PRE-FINISHED TO
MATCH STOREFRONT SYSTEM
LAP FLUID APPLIED VAPOR
BARRIER OVER METAL FLASHING
EXISTING CONCRETE BEAM;
REFER TO STRUCTURAL
BACKER-ROD AND SEALANT
ALUMINUM STOREFRONT SYSTEM
FRAME; ATTACH TO STEEL PLATE5" 2"
SELF-ADHERING BITUTHANE FLASHING
WRAP, REFER TO A625 FOR SEQUENCE
HEAD FLASHING, TYPE F; REFER
TO A620 FOR FLASHING TYPES
ROPE WEEPS @ 6 INCHES O.C.;
CAULK BETWEEN WEEPS ONLY
CLOSURE STRIP BY STOREFRONT
MANUFACTURER
3/8" ENGINEERED SEALANT
JOINT WITH BACKER-ROD
GYPSUM BOARD
METAL CHANNEL
SEALANT
ALUMINUM STOREFRONT SYSTEM
JAMB; ATTACH TO STEEL PLATE
DOOR PANEL
BACKER-ROD & SEALANT
REFER TO STRUCTURAL FOR
CMU REINFORCEMENT SIZE
AND LOCATION(S)
EXISTING BRICK VENEER
METAL STUD/CMU WALL; REFER
TO PLAN(S) AND WALL TYPES
BATT INSULATION
CORNER BEAD
EXISTING CMU
STEEL TUBE; REFER
TO STRUCTURAL
STEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
2" 5"
METAL TRACK; TRIM
AT TUBE STEEL
GYPSUM BOARD; ADHERE TO
STEEL PLATE, ATTACH TO
METAL CHANNEL AND ABUT
STOREFRONT FRAME
FLUID APPLIED VAPOR BARRIER AT NEW
CMU WALL LOCATIONS, APPLY TO
CONCEALED EDGE OF CMU PRIOR TO
INSTALLATION OF STEEL PLATE, REFER TO
EXTERIOR MATERIAL & COLOR SCHEDULE
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
SEALANT
ALUMINUM STOREFRONT SYSTEM
JAMB; ATTACH TO STEEL PLATE
DOOR PANEL
BACKER-ROD & SEALANT
REFER TO STRUCTURAL FOR CMU
REINFORCEMENT SIZE AND LOCATION(S)
EXISTING BRICK VENEER
METAL STUD/SHOTCRETE/CMU WALL;
REFER TO PLAN(S) AND WALL TYPES
BATT INSULATIONCORNER BEAD
EXISTING CMU
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
STEEL ANGLE; REFER TO
STRUCTURAL
STEEL PLATE - REFER
TO STRUCTURAL DWGS.
GYPSUM BOARD; ADHERE TO STEEL
PLATE, ATTACH TO METAL STUD AND
ABUT STOREFRONT FRAME
2" 5"
FLUID APPLIED VAPOR BARRIER;
APPLY TO CONCEALED EDGE OF
EXISTING CMU, IF POSSIBLE, PRIOR
TO INSTALLATION OF STEEL PLATE,
REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
METAL CHANNEL
METAL TRACK; TRIM
AT TUBE STEEL
SEALANT
ALUMINUM STOREFRONT SYSTEM
JAMB; ATTACH TO STEEL PLATE
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
BACKER-ROD & SEALANT
REFER TO STRUCTURAL FOR
CMU REINFORCEMENT SIZE
AND LOCATION(S)
EXISTING BRICK VENEER
METAL STUD/CMU WALL; REFER
TO PLAN(S) AND WALL TYPES
BATT INSULATION
CORNER BEAD
EXISTING CMU
STEEL TUBE - REFER
TO STRUCTURAL DWGS.
STEEL PLATE, WELD TO STEEL
TUBE; REFER TO STRUCTURAL
2" 5"
GYPSUM BOARD; ADHERE TO STEEL PLATE, ATTACH
TO METAL CHANNEL AND ABUT STOREFRONT FRAME
FLUID APPLIED VAPOR BARRIER AT
NEW CMU WALL LOCATIONS, APPLY
TO CONCEALED EDGE OF CMU PRIOR
TO INSTALLATION OF STEEL PLATE,
REFER TO EXTERIOR MATERIAL &
COLOR SCHEDULE
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
SEALANT
ALUMINUM STOREFRONT SYSTEM
JAMB; ATTACH TO STEEL PLATE
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
BACKER-ROD & SEALANT
REFER TO STRUCTURAL FOR
CMU REINFORCEMENT SIZE
AND LOCATION(S)
EXISTING BRICK VENEER
METAL STUD/SHOTCRETE/CMU WALL;
REFER TO PLAN(S) AND WALL TYPES
BATT INSULATIONCORNER BEAD
EXISTING CMU
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
STEEL ANGLE; REFER TO
STRUCTURAL
STEEL PLATE, WELD TO STEEL
ANGLE; REFER TO STRUCTURAL
2" 5"
GYPSUM BOARD; ADHERE TO STEEL
PLATE, ATTACH TO METAL STUD AND
ABUT STOREFRONT FRAME
FLUID APPLIED VAPOR BARRIER; APPLY
TO CONCEALED EDGE OF CMU, IF
POSSIBLE, PRIOR TO INSTALLATION OF
STEEL PLATE, REFER TO EXTERIOR
MATERIAL & COLOR SCHEDULE
SELF-ADHERING BITUTHANE FLASHING
WRAP; REFER TO A625 FOR SEQUENCING
GLAZING; REFER TO
STOREFRONT ELEVATIONS
& GLAZING SCHEDULE
ALUMINUM STOREFRONT DOOR;
REFER TO DOOR SCHEDULE
BRICK VENEER BEYOND
THRESHOLD; SET IN MASTIC; REFER
TO DOOR SCHEDULE & HARDWARE
SETS
EXPANSION JOINT;
REFER TO STRUCTURAL
CONCRETE SIDEWALK;
REFER TO CIVIL
EXISTING CONCRETE SLAB;
REFER TO STRUCTURAL
5" 2"
GLICK/BOEHM
CHARLESTON
NO. B-80006 T
CE
TIHCRADER
ET
SI
G E
R
TH CARO
LIN
A
S
TA
TE
OF
SOU
& ASSOCIATES, INC.
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T
HE
A
IR
F
OR
C E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
A622
EX
TE
RI
OR
S
TO
RE
FR
ON
T
DE
TA
IL
S
GB
KR
S
SM
/30
/20
AD
D/
RE
PA
IR
P
AS
SE
NG
ER
T
ER
M
IN
AL
B
UI
LD
IN
G
DKFX:11-1122 A / B
SCALE: 3" = 1'-0"1 EXTERIOR STOREFRONT (VERTICAL MULLION)
SCALE: 3" = 1'-0"2 EXTERIOR STOREFRONT (SIDELITE @ TRANSOM)
SCALE: 3" = 1'-0"3 EXTERIOR STOREFRONT (HORIZONTAL MULLION)
SCALE: 3" = 1'-0"5 EXTERIOR STOREFRONT (DOOR JAMB @ SIDELITE) (BR)
SCALE: 3" = 1'-0"6 EXTERIOR STOREFRONT (DOOR HEAD @ TRANSOM) (BR)
SCALE: 3" = 1'-0"7 EXTERIOR STOREFRONT HEAD (BR)
SCALE: 3" = 1'-0"8 EXTERIOR STOREFRONT DOOR JAMB (BR)
SCALE: 3" = 1'-0"9 EXTERIOR STOREFRONT DOOR JAMB (BR)
SCALE: 3" = 1'-0"10 EXTERIOR STOREFRONT WINDOW JAMB (BR)
SCALE: 3" = 1'-0"11 EXTERIOR STOREFRONT WINDOW JAMB (BR)
SCALE: 3" = 1'-0"12 EXTERIOR STOREFRONT THRESHOLD (BR)
STEEL CHANNEL; REFER
TO STRUCTURAL
EXISTING CMU
GLAZING
CORNER BEAD
SEALANT; BOTH SIDES, TYP.
ALUMINUM STOREFRONT
SYSTEM FRAME
CORNER BEAD
SHOTCRETE; REFER TO
STRUCTURAL
METAL STUD/SHOTCRETE/CMU
WALL; REFER TO FLOOR PLAN(S)
AND WALL TYPES
STEEL CHANNEL; REFER
TO STRUCTURAL
THREADED THRU-RODS;
REFER TO STRUCTURAL
GYPSUM WALLBOARDGYPSUM WALLBOARD
SHOTCRETE; REFER TO STRUCTURAL
FOR THICKNESS AND LOCATION(S)
STUD/SHOTCRETE/CMU WALL; REFER
TO FLOOR PLANS AND WALL TYPES
GYPSUM WALLBOARD
DOUBLE STUD
AT JAMBS
CORNER BEAD
ALUMINUM STOREFRONT
SYSTEM FRAME
GLAZING; REFER TO STOREFRONT
ELEVATIONS & GLAZING SCHEDULE
EXISTING CMU
3-5/8" METAL STUD
GYPSUM WALLBOARD
REFER TO STRUCTURAL FOR
REINFORCEMENT QUANTITY,
SIZE AND LOCATION(S)
CORNER BEAD
SEALANT; BOTH SIDES, TYP.
WD SHIM
GYPSUM…