Atch 8. 0006--Door Locks Bldgs 1670 530 527 280 Task Order PWS
2 MB Posted
- Attached to
- Sheppard AFB MA-SASC Solicitation Federal contract opportunity
- Solicitation number
- FA3020-10-R-0041
About this file
attachment 8 amendment
Text of this file
FA3020‐10‐R‐0041, A0001A0003
Attachment 8
Task Order # 6 10 Sep 1021 Sep 10
MA-SASC Task Order:
Performance Work Statement on
Building 280, 527, 530 & 1670 Electronic Door Lock (RFID) System
(82 CES/CEHD)
REQUIREMENTS:
82 CES/CEHD has a requirement to install electronic door locking systems in buildings 280, 527, 530 and 1670. The equipment used to install the system shall be radio frequency identification device (RFID) (often referred as proximity locks). The system shall have the capability to program RFID cards to provide access or to deny access to dormitory entrance doors. The RFID cards need to have the ability to be updated, restricted or deleted remotely.
RFID cards need to have ability to be recycled. The dormitory locks shall have the ability to open doors mechanically using conventional keys. Door room locks and deadbolt must meet ANSI Grade 1 standards. All electronics, cabling and switches used in the system must meet current Air Force configuration standards IAW AFI 31-101, "Air Force Physical Security Program. The system shall include initial user training and include a minimum 1-year maintenance agreement for all installed equipment.
Installation
This system shall cover the facility areas as detailed below.
Exterior: All entrance doors in Bldg 280, 527, 530 and 1670 will have mortise or cylindrical locks installed depending on the current door’s lock style.
Interior: All entrance doors in Bldg 280, 527, 530 and 1670 will have mortise or cylindrical locks installed depending on the current door’s lock style. All electronic control equipment will be installed Buildings 373, 530 and 1670.
The contractor shall design the system based on the building diagram in the Exhibits 1-4 building layouts.
The contractor shall provide all necessary system design elements. All required equipment, software, hardware; cabling and electrical connections shall be provided and installed by the contractor.
The contractor shall be responsible for coordinating all installation permits and facility modification/construction requests through 82d Civil Engineering Squadron (DS2), 82d Security Forces Squadron, and 82d Civil Engineering Squadron Fire Department.
Door Breakout/type by Building
Building
Number of Doors w/ Panic Bars (Monarch Exit Device currently installed)
Number of Cylindrical Locks Currently Installed
Number of Mortise Locks Currently Installed
Number of Doors (total)
280 2 0 208 210 527 0 0 96 96 530 4 0 6 10 1670 1 183 0 184 Totals 7 183 310 500
Exhibits
1. 82 CES/CEHD SAFB Building 280 Layout
2. 82 CES/CEHD SAFB Building 527 Layout
3. 82 CES/CEHD SAFB Building 530 Layout
4. 82 CES/CEHD SAFB Building 1670 Layout
5. Pictures of existing dorm door hardware
Task Order Contract Line Items (CLINS):
CLIN Description 0001 Design an electronic door lock system using RFID technology for Bldg 280, 527, 530 and 1670 to be controlled from 373, 530 and 1670.
0002 Provide and install all equipment and supplies for the electronic door lock (RFID) system.
0003 Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
CLIN Description
(Base)
Design an electronic door lock system using RFID technology for Bldg 1670 to be controlled from 373, 530 and 1670.
(Base)
Provide and install all equipment and supplies for the Bldg 1670 electronic door lock (RFID) system.
(Base)
Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the Bldg 1670 system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
(Option)
Design an electronic door lock system using RFID technology for Bldg 530 to be controlled from 373, 530 and 1670.
(Option)
Provide and install all equipment and supplies for the Bldg 530 electronic door lock (RFID) system.
(Option)
Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the Bldg 530 system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
(Option)
Design an electronic door lock system using RFID technology for Bldg 527 to be controlled from 373, 530 and 1670.
(Option)
Provide and install all equipment and supplies for the Bldg 527 electronic door lock (RFID) system.
(Option)
Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the Bldg 527 system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
00010 (Option)
Design an electronic door lock system using RFID technology for Bldg 280 to be controlled from 373, 530 and 1670.
00011 (Option)
Provide and install all equipment and supplies for the Bldg 280 electronic door lock (RFID) system.
00012 (Option)
Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the Bldg 280 system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
Exhibit 1
Exhibit 1
Permanent Party- First, Second, and Third Floors Building 527
N
A
Exhibit 2
Exhibit 3
Randell.Smith Line
Dorm Managers Office #119 Janitor #124
BUILDING 1670
1ST FLOOR QUAD 102-110
Exhibit 4
STORAGE
ROOM #219
2ND FLOOR QUAD 202-210
Mechanical Room
3RD FLOOR QUAD 302-310
Roof Access
4TH FLOOR QUAD 402-410
3 Sep 201010 Sep 10
Exhibit 5
Dorms 280 and 527 Hardware
Dorm 530 (side view)
Dorms 280, 527 frame view
Dorm 530 Door Hardware