7. 0005--Public Address Systems Hangars 1040 1080 and 1090 Task Order PWS.pdf

PDF 3 MB Posted

Attached to
Sheppard AFB MA-SASC Solicitation Federal contract opportunity
Solicitation number
FA3020-10-R-0041
Issued by
Department of the Air Force Air Education and Training Command

About this file

FA3020-10-R-0041 7. 0005--Public Address Systems Hangars 1040 1080 and 1090 Task Order PWS

View the file

Other files for this federal contract opportunity

Other files attached to Sheppard AFB MA-SASC Solicitation, newest first.
File Type Posted
Amendment 0003 —
Atch 8. 0006--Door Locks Bldgs 1670 530 527 280 Task Order PWS —
Atch 5. 0003--82 TRG Dorms 596 776 862 Task Order PWS —
1. M -SASC PWS Final —
Amendment 0002 —
16. M -SASC ITO Eval Criteria —
7. 0005--PA Systems Hangars 1040 1080 1090 Task Order PWS —
6. 0004--Courthouse Vindicator Duress Alarms Task Order PWS —
7. 0005--PA Systems Hangars 1040 1080 1090 Task Order PWS —
4. 0002--Post Office Surveillance Task Order PWS —
8. 0006--Door Locks Bldgs 280 527 530 1670 Task Order PWS —
16. M -SASC ITO Eval Criteria.pdf PDF
5. 0003--82 TRG Dorms 596 776 862 Task Order PWS —
1. M -SASC PWS Final —
3. 0001--Dorm 622 Task Order PWS —
Amendment 0001 —
M -SASC Site Visit.pptx PPTX presentation
Initial M -SASC Task Orders —
Sheppard AFB Contractors —
M -SASC RFP.pdf PDF
14. Base Pass Forms.pdf PDF
5. 0003--82 TRG Dorms 596 776 862 Task Order PWS.pdf PDF
6. 0004--Courthouse Vindicator Duress Alarms Task Order PWS.pdf PDF
9. Service Contract WD TX 2005-2525.pdf PDF
M -SASC RFP.pdf PDF
13. Past Performance Questionnaire.pdf PDF
4. 0002--Post Office Surveillance Task Order PWS.pdf PDF
10. General WD TX 43.pdf PDF
11. General WD TX 302.pdf PDF
12. Contractor Past Performance Submittal Form.pdf PDF
2. SECTION 13280 Asbestos Abatetement.pdf PDF
8. 0006--Electronic Door Lock Systems Bldgs 280 527 530 1670 Task Order PWS.pdf PDF
1. M -SASC PWS Final —
15. M -SASC Performance Plan.pdf PDF
3. 0001--Dorm 622 Task Order PWS.pdf PDF
Show all 35

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Task Order #5 5 Sep 2010

MA-SASC Task Order:

Performance Work Statement on

Intercom/Paging Systems Hangars 1040, 1080, and 1090

REQUIREMENTS:

Exhibits

1. First and Second Floor Drawings; Hangars 1040, 1080, & 1090

2. Hangar 1040 Asbestos Survey (45 pages)

3. Hangar 1080 Asbestos Survey (25 pages)

4. Hangar 1090 Asbestos Survey (1 page)

Task Order #5 5 Sep 2010

Task Order Contract Line Items (CLINS):

CLIN Description

Design a turnkey, IP based, private network, intercom/paging system for Hangars 1040, 1080, and 1090, Sheppard AFB TX

0002 Provide and install all equipment and supplies for the intercom/paging system for Hangar 1040

0003 Provide and install all equipment and supplies for the intercom/paging system for Hangar 1080

0004 Provide and install all equipment and supplies for the intercom/paging system for Hangar 1090

Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system

Exhibit 1

SHEPPARD AFB

ASBESTOS-CONTAINING BUILDING MATERIALS

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 2 Ceiling Sheetrock 2300 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Hall 5 Floor Vinyl composite tile

935 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 Hall 5 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Hall 5 Chilled Water System Piping

Mud fittings 2 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 Hall 4 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Tuesday, August 17, 2010 Page 1 of 45

Exhibit 2

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 4 Floor Vinyl composite tile

935 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 Hall 4 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Hall 4 Chilled Water System Piping

Fittings 2 ftgs Positive 3

Not Abated

Galson 1993 Hall 3 Floor Vinyl composite tile

2500 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 Hall 3 Ceiling Sheetrock 2300 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 2 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 3 Wall Sheetrock 40000 sq ft Positive 3

Not Abated

Galson 1993 Hall 2 Fitting Insulation Negative Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 5 Wall Sheetrock 2400 sq ft Positive 3

Not Abated

Galson 1993 Hall 2 Wall Transite 15 sq ft Assumed positive

Not Abated

Galson 1993 Miscellaneo us 1

Wall Sheetrock 800 sq ft Positive 3

Not Abated

Tuesday, August 17, 2010 Page 3 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 2 Wall Sheetrock 4900 sq ft Positive 3

Not Abated

Galson 1993 Hall 1 Fitting Insulation Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Hall 1 Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Hall 1 Wall Transite 15 sq ft Assumed positive

Not Abated

Galson 1993 Hall 1 Ceiling Sheetrock 2000 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 4 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 1 Wall Sheetrock 4500 sq ft Positive 3

Not Abated

Galson 1993 Exterior Wall Transite 17000 sq ft Assumed positive

Not Abated

Galson 1993 Classroom 6 Ceiling Tile - Lay In Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 6 Wall Sheetrock 3800 sq ft Positive 3

Not Abated

Galson 1993 Classroom 5 Ceiling Tile - Lay In Negative Fiberglass, non-suspect ACM

Not Abated

Tuesday, August 17, 2010 Page 5 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER5 Ceiling Sheetrock 63 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Galson 1993 Hall 2 Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Stair 3 Floor Vinyl composite tile

30 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 MER1 Ceiling Sheetrock 800 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Galson 1993 MER1 Wall Sheetrock 1200 sq ft Positive 2

Not Abated

Tuesday, August 17, 2010 Page 6 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER1 Hot Water Heating Piping

Mud fittings 12 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 MER1 Chilled Water System Piping

Mud fittings 20 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 Stair 6 Floor Vinyl composite tile

160 sq ft Assumed positive

7 12" x 12" white with beige streaks

Not Abated

Galson 1993 Stair 6 Ceiling Sheetrock 160 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Stair 6 Wall Sheetrock 840 sq ft Positive 3

Not Abated

Tuesday, August 17, 2010 Page 7 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 5 Floor Vinyl composite tile

160 sq ft Assumed positive

7 12" x 12" white with beige streaks

Not Abated

Galson 1993 Stair 5 Ceiling Sheetrock 160 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Stair 5 Wall Sheetrock 840 sq ft Positive 3

Not Abated

Galson 1993 Stair 4 Floor Vinyl composite tile

30 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 Hall 5 Wall Transite 15 sq ft Assumed positive

Not Abated

Tuesday, August 17, 2010 Page 8 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 4 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Hall 5 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Stair 3 Ceiling Sheetrock 378 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Stair 3 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Stair 2 Floor Vinyl composite tile

30 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Tuesday, August 17, 2010 Page 9 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 2 Ceiling Tile - Lay In 250 sq ft Negative 2' x 4' white, small and large perforation

Not Abated

Galson 1993 Stair 2 Ceiling Sheetrock 400 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Stair 2 Wall Sheetrock 850 sq ft Positive 3

Not Abated

Galson 1993 Stair 1 Floor Vinyl composite tile

30 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 Stair 1 Ceiling Tile - Lay In 250 sq ft Negative 2' x 4' white, small and large perforation

Not Abated

Tuesday, August 17, 2010 Page 10 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 1 Ceiling Sheetrock 400 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Stair 1 Wall Sheetrock 850 sq ft Positive 3

Not Abated

Galson 1993 Miscellaneo us 1

Ceiling Sheetrock 400 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Classroom 4 Floor Vinyl composite tile

1600 sq ft Assumed positive

7 9" x 9" green with white streaks

Not Abated

Galson 1993 Stair 4 Ceiling Sheetrock 378 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 11 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER6 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Office 3 Ceiling Ceiling Tile 2900 sq ft Negative

Not Abated

Galson 1993 Office 3 Wall Sheetrock 5200 sq ft Positive 2

Not Abated

Galson 1993 Office 2 Battery Insulation Material

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling

Not Abated

Galson 1993 Office 2 Domestic Water Pipe Insulation

Fiberglass 240 sq ft Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Tuesday, August 17, 2010 Page 12 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Office 2 Floor Ninyl Composite Tile Floor

480 sq ft Assumed positive

7 Under carpet

Not Abated

Galson 1993 Office 2 Ceiling Ceiling Tile 240 sq ft Negative 2' X 4' White; grooved into 2' X 2' sections fissured appearance

Not Abated

Galson 1993 Office 2 Ceiling Ceiling Tile 240 sq ft Negative 2' X 4' White; Small and Large Perforation.

Not Abated

Galson 1993 Office 2 Wall Sheetrock 12800 sq ft Positive 3

Not Abated

Galson 1993 Office 1 Floor Vinyl Composite Tile Floor

1600 sq ft Assumed positive

7 9" X 9" gren with white streaks. Under Carpet.

Not Abated

Tuesday, August 17, 2010 Page 13 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Office 1 Ceiling Ceiling Tile 1600 sq ft Negative 2' X 4' White; Small and large perforation

Not Abated

Galson 1993 Office 1 Wall Sheetrock 2400 sq ft Positive 3

Not Abated

Galson 1993 Classroom 5 Ceiling Tile - Lay In 88 sq ft Negative 2' x 4' white, tiny fissured and perforations

Not Abated

Galson 1993 MER6 Piping - Heating Hot Water

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Office 4 Ceiling Sheetrock 80 sq ft Positive 3 Wall and ceiling material considered indentical

Not Abated

Tuesday, August 17, 2010 Page 14 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER6 HVAC-Flexible duct/flex duct J

Insulation 80 sq ft Assumed positive

Not Abated

Galson 1993 MER6 Domestic Water Piping

Mud fittings 1 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 MER6 Ceiling Sheetrock 870 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Galson 1993 MER6 Wall Sheetrock 1200 sq ft Positive 2

Not Abated

Galson 1993 MER6 Hot Water Heating Piping

Mud fittings 10 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Tuesday, August 17, 2010 Page 15 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER6 HVAC-Duct surface-trowelled

Insulation 600 sq ft Positive 2

Not Abated

Galson 1993 MER6 Chilled Water System Piping

Fittings 32 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 MER5 Domestic Water Pipe

Insulation Negative Fiberglass, non-suspect ACM

Not Abated

Galson 1993 MER5 Fitting on pipe Tar wrap 5 ftgs Negative

Not Abated

Galson 1993 MER5 Domestic Water Fitting

Mud fittings 8 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Tuesday, August 17, 2010 Page 16 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER5 Mech Equip - Domestic Hot Water

Insulation 94 sq ft Positive 3

Not Abated

Galson 1993 MER6 Domestic Water Fitting Insulation

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 1 Ceiling Tile - Lay In 1600 sq ft Negative 2' x 4' white fissured pattern

Not Abated

Galson 1993 Classroom 4 Ceiling Tile - Lay In 800 sq ft Negative 2' x 4' white, tiny fissured and perforatiions

Not Abated

Galson 1993 Classroom 4 Ceiling Tile - Lay In 800 sq ft Negative 2' x 4' white, small and large perforation

Not Abated

Tuesday, August 17, 2010 Page 17 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 4 Wall Sheetrock 2400 sq ft Positive 3

Not Abated

Galson 1993 Classroom 3 Floor Vinyl composite tile

1600 sq ft Assumed positive

7 12" x 12" white with black streaks

Not Abated

Galson 1993 Classroom 3 Ceiling Tile - Lay In 600 sq ft Negative 2' x 4' white, small and large perforation

Not Abated

Galson 1993 Classroom 3 Wall Sheetrock 2400 sq ft Positive 3

Not Abated

Galson 1993 Classroom 2 Floor Vinyl composite tile

1200 sq ft Assumed positive

7 12" x 12" white with black streaks

Not Abated

Tuesday, August 17, 2010 Page 18 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 2 Ceiling Tile - Lay In 800 sq ft Negative 2' x 4' white, small and large perforation

Not Abated

Galson 1993 Classroom 2 Ceiling Sheetrock 400 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Classroom 2 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Classroom 1 Ceiling Tile - Lay In Negative Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Office 3 Duct Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Tuesday, August 17, 2010 Page 19 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 1 Floor Vinyl composite tile

1600 sq ft Assumed positive

7 12" x 12" white with beige streaks, under carpet

Not Abated

Galson 1993 Office 3 Battery Insulation Material

Fiberglass 2900 sq ft Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Classroom 1 Ceiling Tile - Lay In 11000 sq ft Negative 2' x 4' white, grooved into 2' x 2' sections, fissured appearance

Not Abated

Galson 1993 Classroom 1 Ceiling Tile - Lay In 8600 sq ft Negative 2' x 4' white, small and large perforation

Not Abated

Galson 1993 Classroom 1 Ceiling Sheetrock 399 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 20 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 1 Wall Sheetrock 33000 sq ft Positive 2

Not Abated

Galson 1993 Office 4 Duct Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Office 4 Battery Insulation Material

Fiberglass Assumed negative

Above ceiling. Fiberglass, non-suspect ACM.

Not Abated

Galson 1993 Office 4 Floor Vinyl Composite Tile Floor

6500 sq ft Assumed Positive

7 9" X 9" green with white streaks

Not Abated

Galson 1993 Office 4 Ceiling Ceiling Tile 320 sq ft Negative 2' X 4' White; tiny fissured and perforations.

Not Abated

Tuesday, August 17, 2010 Page 21 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Office 4 Ceiling Ceiling Tile 210 sq ft Negative 2' X 4' White fissured pattern

Not Abated

Galson 1993 Office 4 Ceiling Ceiling Tile 300 sq ft Negative 2' X 4' White; Small and Large Perforation.

Not Abated

Galson 1993 Office 4 Wall Sheetrock 10500 sq ft Positive 3

Not Abated

Galson 1993 MER1 Domestic water piping

Insulation 5 ft Positive 2

Not Abated

Galson 1993 Classroom 1 Wall Transite 15 sq ft Assumed positive

Not Abated

Tuesday, August 17, 2010 Page 22 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1997 1 FTB Floor Tile B 7% Fair

Not Abated

1999 1 SR Sheetrock NAD Fair White.

Not Abated

1996 5 SR Sheetrock NAD Fair

Not Abated

1996 4 SR Sheetrock NAD Fair

Not Abated

1996 3 MAST Mastic NAD Fair

Not Abated

Tuesday, August 17, 2010 Page 23 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1996 3 FT Floor Tile NAD Fair

Not Abated

1996 2 MAST Mastic 3% Chrysotile Fair

Not Abated

1996 2 FT Floor Tile 3% Chrysotile Fair

Not Abated

1996 1 MAST Mastic 3% Chrysotile Fair

Not Abated

1996 1 FT Floor Tile 3% Chrysotile Fair

Not Abated

Tuesday, August 17, 2010 Page 24 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1997 3 SR Sheetrock NAD Fair

Not Abated

1997 2 SR Sheetrock NAD Fair

Not Abated

Galson 1993 MER1 Mechanical Equipment - Tank

Insulation 32 sq ft Positive/Inconc lusive

Not Abated

1997 2 CT Ceiling Tile NAD Fair

Not Abated

2001 1 Trainer Unit F-16 TSI Thermal System Insulation

NAD Fair Gray.

Not Abated

Tuesday, August 17, 2010 Page 25 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1997 1 FTA Floor Tile A NAD Fair

Not Abated

Galson 1993 Toilet 2 Domestic Water Pipe Insulation

Fiberglass Assumed negative

Fiberglass, Non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Toilet 2 Battery Insulation Material

Fiberglass Assumed negative

Above ceiling. Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Toilet 2 Ceiling Sheetrock 840 sq ft Positive 4 Wall and ceiling material considered identical

Not Abated

Galson 1993 Toilet 2 Wall Sheetrock 13600 sq ft Positive 4

Not Abated

Tuesday, August 17, 2010 Page 26 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Toilet 1 Ceiling Sheetrock 928 sq ft Positive 3 Wall and ceiling material considered identical

Not Abated

Galson 1993 Toilet 1 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Storage 4 Ceiling Ceiling Tile Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Storage 4 Floor Vinyl Composite Tile Floor

3000 sq ft Assumed positive

7 12" X 12" White with black streaks

Not Abated

Galson 1993 Storage 4 Ceiling Ceiling Tile 89 sq ft Negative 2' X 4' white; Tiny fissured and perforations

Not Abated

Tuesday, August 17, 2010 Page 27 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Storage 4 Wall Sheetrock 6400 sq ft Positive 3

Not Abated

1997 3 FT Floor Tile NAD Fair

Not Abated

1997 11 CT Ceiling Tile NAD Fair

Not Abated

2009 wall C111-3 sheetrock <1% chrysolite

Not Abated

2009 wall C111-2 sheetrock 2% chrysolite

Not Abated

Tuesday, August 17, 2010 Page 28 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

2009 Wall C111-1 sheetrock <1% chrysolite

Not Abated

1997 1 SR Sheetrock NAD Fair

Not Abated

1997 4 SR Sheetrock NAD Fair

Not Abated

1997 3 SR Sheetrock NAD Fair

Not Abated

1997 2 SR Sheetrock NAD Fair

Not Abated

Tuesday, August 17, 2010 Page 29 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1997 1 SR Sheetrock NAD Fair

Not Abated

1997 16 FT Floor Tile 10% Fair

Not Abated

1997 15 CT Ceiling Tile NAD Fair

Not Abated

1997 14 CT Ceiling Tile NAD Fair

Not Abated

1999 2 SR Sheetrock NAD Fair White.

Not Abated

Tuesday, August 17, 2010 Page 30 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1997 12 FT Floor Tile NAD Fair

Not Abated

1999 3 SR Sheetrock NAD Fair White.

Not Abated

1997 10 CT Ceiling Tile NAD Fair

Not Abated

1997 9 FT Floor Tile NAD Fair

Not Abated

1997 8 CT Ceiling Tile NAD Fair

Not Abated

Tuesday, August 17, 2010 Page 31 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

1997 7 FT Floor Tile NAD Fair

Not Abated

1997 6 CT Ceiling Tile NAD Fair

Not Abated

1997 5 FT Floor Tile 2% Chrysotile Fair 7% in green tile, NAD in white tile.

Not Abated

1997 4 CT Ceiling Tile NAD Fair

Not Abated

2001 3 Trainer Unit F-16 TSI Thermal System Insulation

NAD Fair White.

Not Abated

Tuesday, August 17, 2010 Page 32 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

2001 3 Trainer Unit F-16 TSI Thermal System Insulation

NAD Fair Gray.

Not Abated

2001 2 Trainer Unit F-16 TSI Thermal System Insulation

NAD Fair Gray.

Not Abated

2001 1 Trainer Unit F-16 TSI Thermal System Insulation

NAD Fair White.

Not Abated

Galson 1993 Storage 3 Ceiling Ceiling Tile Assumed negative

Fiberglass, non-suspect ACM

Not Abated

1997 13 CT Ceiling Tile NAD Fair

Not Abated

Tuesday, August 17, 2010 Page 33 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER2 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Storage 3 Battery Insulation Material

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 MER4 Hot Water Heating Piping

Mud fittings 10 ftgs Positive 3

Not Abated

Galson 1993 MER4 HVAC-Duct surface-trowelled

Insulation 350 sq ft Positive 2

Not Abated

Galson 1993 MER4 Chilled Water System Piping

Fittings 18 ftgs Positive 3

Not Abated

Tuesday, August 17, 2010 Page 34 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER3 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 MER3 Hot Water Heating Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 MER3 HVAC-Flexible duct/flex duct J

Insulation 80 sq ft Assumed positive

Not Abated

Galson 1993 MER3 Ceiling Sheetrock 841 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Galson 1993 MER3 Wall Sheetrock 1100 sq ft Positive 2

Not Abated

Tuesday, August 17, 2010 Page 35 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER3 Hot Water Heating Piping

Mud fittings 12 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 MER3 HVAC-Duct surface-trowelled

Insulation 800 sq ft Positive 1

Not Abated

Galson 1993 MER4 Ceiling Sheetrock 400 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Galson 1993 MER2 Hot Water Heating Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 MER4 HVAC-Flexible duct/flex duct J

Insulation 80 sq ft Assumed positive

Not Abated

Tuesday, August 17, 2010 Page 36 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER2 HVAC-Flexible duct/flex duct J

Insulation 80 sq ft Assumed positive

Not Abated

Galson 1993 MER2 Ceiling Sheetrock 399 sq ft Positive 2 Wall and ceiling material considered identical

Not Abated

Galson 1993 MER2 Wall Sheetrock 800 sq ft Positive 2

Not Abated

Galson 1993 MER2 Hot Water Heating Piping

Mud fittings 6 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 MER2 HVAC-Duct surface-trowelled

Insulation 400 sq ft Positive 2

Not Abated

Tuesday, August 17, 2010 Page 37 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER2 Chilled Water System Piping

Mud fittings 12 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Galson 1993 MER1 Mechanical Equipment

Insulation Assumed negative

Rubber material

Not Abated

Galson 1993 MER1 Hot Water Heating Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 MER1 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 MER1 Mechanical Equipment

Gasket 3 sq ft Assumed positive

Not Abated

Tuesday, August 17, 2010 Page 38 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER1 Domestic water fitting

Insulation 24 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

2009 wall A108A-1 sheetrock <1 %chrysolite

Not Abated

Galson 1993 MER3 Chilled Water System Piping

Fittings 16 ftgs Positive 3

Not Abated

Galson 1993 Shop 1 Ceiling Ceiling Tile 480 sq ft Negative 2' X 4' White fissured pattern

Not Abated

Galson 1993 MER1 Fitting on pipe Tar wrap 4 ftgs Negative

Not Abated

Tuesday, August 17, 2010 Page 39 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Storage 3 Wall Sheetrock 1100 sq ft Positive 3

Not Abated

Galson 1993 Storage 2 Ceiling Ceiling Tile Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Storage 2 Battery Insulation Material

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Storage 2 Duct Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Storage 2 Ceiling Ceiling Tile 5700 sq ft Negative 2' X 4' White; Tiny fissured and perforations

Not Abated

Tuesday, August 17, 2010 Page 40 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Storage 2 Wall Sheetrock 6800 sq ft Positive 3

Not Abated

Galson 1993 Storage 1 Ceiling Ceiling Tile Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Storage 1 Floor Vinyl Composite Tile Floor

1200 sq ft Assumed positive

7 12" X 12" White with beige streaks

Not Abated

Galson 1993 Storage 1 Ceiling Ceiling Tile 64 sq ft Negative 2' X 4' White fissured pattern

Not Abated

Galson 1993 Storage 1 Wall Sheetrock 2000 sq ft Positive 7

Not Abated

Tuesday, August 17, 2010 Page 41 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 MER4 Wall Sheetrock 619 sq ft Positive 2

Not Abated

Galson 1993 Shop 1 Wall Wall Transite 15 sq ft Assumed positive

Not Abated

Galson 1993 Storage 3 Duct Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Shop 1 Wall Sheetrock 2000 sq ft Positive 3

Not Abated

Galson 1993 Shop 1 Chilled Water System Fittings

Fittings 6 ftgs Positive 3 Mud fittings on fiberglass line

Not Abated

Tuesday, August 17, 2010 Page 42 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Roof Wall Wall Transite 3400 sq ft Assumed positive

Not Abated

Galson 1993 Roof Asphalt and Gravel

Asphalt and Gravel

75000 sq ft Assumed positive

Not Abated

Galson 1993 Office 6 Battery Insulation Material

Fiberglass Assumed negatie

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Office 6 Duct Fiberglass Assumed negatie

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Office 6 Ceiling Ceiling Tile Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Tuesday, August 17, 2010 Page 43 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Office 6 Ceiling Ceiling Tile 1100 sq ft Negative 2' X 4' white; grooved into 2' X 2'

Not Abated

Galson 1993 Office 6 Wall Sheetrock 2400 sq ft Positive 3

Not Abated

Galson 1993 MER5 Wall Sheetrock 320 sq ft Positive 2

Not Abated

Galson 1993 MER4 HVAC - Duct Joint

Tape compound

30 sq ft Assumed positive

Not Abated

Galson 1993 MER4 Fitting on pipe Tar wrap 2 ftgs Negative

Not Abated

Tuesday, August 17, 2010 Page 44 of 45

Bldg No/Street Address 1040 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Shop 1 Chilled Water System Fittings

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Tuesday, August 17, 2010 Page 45 of 45

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 2 Floor Vinyl Composite Tile Floor

2400 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Hall 4 Ceiling Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 5 Ceiling Ceiling Tile 3200 sq ft Pos/Incon. 3 2' X 4' White with two-sized perforations

Not Abated

Galson 1993 Classroom 5 Floor Vinyl Composite Tile Floor

2000 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Classroom 5 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Tuesday, August 17, 2010 Page 1 of 25

Exhibit 3

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 5 Chilled Water System Fittings

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 5 HVAC - Flexible Duct/Flexible Duct Joint

Rubber Material Assumed negative

Rubber Material

Not Abated

Galson 1993 Exterior Wall Wall Transite 17000 sq ft Assumed positive

Not Abated

Galson 1993 Hall 1 Wall Sheetrock 2600 sq ft Trace

Not Abated

Galson 1993 Hall 1 Ceiling Sheetrock 432 sq ft Trace Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 2 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 1 Chilled Water system Fittings

Mud Fittings 1 ftg Positive 4 Mud fittings on fiberglass line

Not Abated

Galson 1993 Hall 1 Floor Vinyl Composite Tile Floor

2400 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Hall 1 Ceiling Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Hall 2 Wall Sheetrock 2600 sq ft Trace

Not Abated

Galson 1993 Classroom 5 Wall Sheetrock 5100 sq ft Trace

Not Abated

Tuesday, August 17, 2010 Page 3 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 3 Floor Vinyl Composite Tile Floor

2400 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Classroom 1 Floor Vinyl Composite Tile Floor

800 sq ft Assumed positive

7 12" X 12" Beige with brown streaks

Not Abated

Galson 1993 Hall 4 Chilled Water System Fittings

Mud Fittings 1 ftg Positive 4 Mud fittings on fiberglass line

Not Abated

Galson 1993 Hall 4 Ceiling Sheetrock 432 sq ft Trace Wall and ceiling material considered identical

Not Abated

Galson 1993 Hall 4 Wall Sheetrock Trace

Not Abated

Tuesday, August 17, 2010 Page 4 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 4 Wall Sheetrock Trace

Not Abated

Galson 1993 Hall 2 Ceiling Sheetrock 432 sq ft Trace Wall and ceiling material considered identical

Not Abated

Galson 1993 Hall 3 Ceiling Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Hall 2 Chilled Water system Fittings

Mud Fittings 1 ftg Positive 4 Mud fittings on fiberglass line

Not Abated

Galson 1993 Hall 3 Chilled Water System Fittings

Mud Fittings 1 ftg Positive 4 Mud fittings on fiberglass line

Not Abated

Tuesday, August 17, 2010 Page 5 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 3 Ceiling Sheetrock 432 sq ft Trace Wall and ceiling material considered identical

Not Abated

Galson 1993 Hall 3 Wall Sheetrock 2600 sq ft Trace

Not Abated

Galson 1993 Hall 2 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Hall 2 Ceiling Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 4 Floor Vinyl Composite Tile Floor

5000 sq ft Assumed positive

7 9" X 9" Green with white streaks. Under Carpet.

Not Abated

Tuesday, August 17, 2010 Page 6 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 3 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 1 Wall Sheetrock 3800 sq ft Trace

Not Abated

Galson 1993 Classroom 1 Battery Insulation Material

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Classroom 1 Pipe Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 1 Fitting (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Tuesday, August 17, 2010 Page 7 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 1 HVAC - Flexible Duct/Flexible Joint

Rubber Material Assumed negative

Rubber material

Not Abated

Galson 1993 Classroom 2 Wall Sheetrock 4700 sq ft Trace

Not Abated

Galson 1993 Classroom 2 Ceiling Ceilng Tile 4100 sq ft Pos/Incon. 2 2' X 4' White with two-sized perforations

Not Abated

Galson 1993 Classroom 2 Duct Foil over Fiberglass

320 sq ft Positive 3 Foil over fiberglass with tar sealing the seams. Above ceiling.

Not Abated

Galson 1993 Classroom 2 Pipe (type not specified)

Fiberglass Assumed negative

Above Ceiling. Fiberglass, non-suspect ACM.

Not Abated

Tuesday, August 17, 2010 Page 8 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 2 Fitting (type not specified)

Fiberglass Assumed negative

Above ceiling. Fiberglass, non-suspect ACM.

Not Abated

Galson 1993 Classroom 2 HVAC - Flexible Duct/Flexible Duct Joint

Rubber Material Assumed negative

Rubber material

Not Abated

Galson 1993 Classroom 2 Battery Insulation Material

Foam Rubber Assumed negative

Foam rubber. Non-suspect ACM. Above ceilng.

Not Abated

Galson 1993 Classroom 3 Wall Sheetrock 3800 sq ft Trace

Not Abated

Galson 1993 Classroom 3 Ceiling Ceilng Tile 3000 sq ft Pos/Incon. 3 2' X 4' White with two-sized perforations

Not Abated

Tuesday, August 17, 2010 Page 9 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 5 Ceiling Sheetrock 56 sq ft Trace Wall and ceiling material considered identical

Not Abated

Galson 1993 Classroom 6 Wall Sheetrock 5300 sq ft Trace

Not Abated

Galson 1993 Classroom 4 Ceiling Ceilng Tile 5000 sq ft Pos/Incon. 2 2' X 4' White with two-sized perforations

Not Abated

Galson 1993 Classroom 4 Wall Sheetrock 6600 sq ft Trace

Not Abated

Galson 1993 Classroom 6 Chilled Water System Fittings

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Supplies hot and chilled water to building.

Not Abated

Tuesday, August 17, 2010 Page 10 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 6 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Supplies hot and chilled water to building.

Not Abated

Galson 1993 Classroom 6 Floor Vinyl Composite Tile Floor

3300 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Classroom 3 Ceilng Ceiling Tile 200 sq ft Negative 2' X 4' White with large fissures.

Not Abated

Galson 1993 Classroom 6 Ceiling Ceiling Tile 3200 sq ft Pos/Incon. 3 2' X 4' White with two-sized perforations

Not Abated

Galson 1993 Classroom 3 Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Tuesday, August 17, 2010 Page 11 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Classroom 3 HVAC - Flexible Duct/Flexible Duct Joint

Rubber Material Assumed negative

Rubber Material

Not Abated

Galson 1993 Classroom 3 Battery Insulation Material

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Classroom 3 Fitting (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Classroom 1 Ceiling Ceiling Tile 100 sq ft Negative 2' X 4' White with large fissures

Not Abated

Galson 1993 Classroom 1 Ceiling Ceiling Tile 3100 sq ft Pos/Incon. 2 2' X 4' White with two-sized perforations

Not Abated

Tuesday, August 17, 2010 Page 12 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Hall 4 Chilled Water System Piping

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Classroom 6 Ceiling Ceiling Tile 56 sq ft Negative 2' X 4' With white large fissures

Not Abated

Galson 1993 Store 1 Floor Vinyl Composite Tile Floor

260 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Hall 4 Floor Vinyl Composite Tile Floor

2400 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Shop 2 Wall Sheetrock 2400 sq ft Trace

Not Abated

Tuesday, August 17, 2010 Page 13 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Shop 2 Chilled Water System Fittings

Mud Fittings 8 ftgs Positive 4 Mud fittings on fiberglass line

Not Abated

Galson 1993 Shop 2 Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Shop 2 Ceiling Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Store 3 Wall Sheetrock 1300 sq ft Trace

Not Abated

Galson 1993 Store 3 Ceiling Ceiling Tile 1700 sq ft Pos/Incon. 2 2' X 4' White with two-sized perforations

Not Abated

Tuesday, August 17, 2010 Page 14 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Store 3 Duct Foil over fiberglass

50 sq ft Positive 3 Foil over fiberglass with tar sealing the seams. Above ceiling.

Not Abated

Galson 1993 Store 3 Floor Vinyl Composite Tile Floor

1700 sq ft Assumed positive

7 12" X 12" Beige with brown streaks

Not Abated

Galson 1993 Store 3 Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Store 3 Fitting (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Store 3 HVAC - Flexible Duct/Flexible Duct Joint

Rubber Material Assumed negative

Rubber material

Not Abated

Tuesday, August 17, 2010 Page 15 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Store 1 Wall Sheetrock 838 sq ft Trace

Not Abated

Galson 1993 Shop 1 Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Store 1 Ceiling Ceiling Tile 231 sq ft Pos/Incon. 3 2' X 4' White with two-sized perforations

Not Abated

2005 wall 1080-SR-4 Cellulose <1

Not Abated

2005 wall 1080-SR-3 Cellulose <1

Not Abated

Tuesday, August 17, 2010 Page 16 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

2005 wall 1080-SR-2 Cellulose <1

Not Abated

2005 wall 1080-SR-1 Cellulose <1

Not Abated

Galson 1993 Toilet Pipe (type not specified)

Fiberglass Assumed negative

Fiberglass, non-suspect ACM. Above ceiling.

Not Abated

Galson 1993 Store 1 Ceiling Sheetrock 56 sq ft Trace Wall and ceiling material considered identical

Not Abated

Galson 1993 Toilet Ceiling Sheetrock 800 sq ft Trace Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 17 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Store 1 Ceiling Ceiling Tile 260 sq ft Pos/Incon. 3 2' X 4' White with two-sized perforations

Not Abated

Galson 1993 Store 4 Wall Sheetrock 619 sq ft Trace

Not Abated

Galson 1993 Store 2 Floor Vinyl Composite Tile Floor

260 sq ft Assumed positive

7 9" X 9" Green with white streaks

Not Abated

Galson 1993 Store 2 Ceiling Ceiling Tile 260 sq ft Pos/Incon. 3 2' X 4' White with two-sized perforations

Not Abated

Galson 1993 Store 2 Ceiling Sheetrock 56 sq ft Trace Wall and ceiling material considered identical

Not Abated

Tuesday, August 17, 2010 Page 18 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Store 2 Wall Sheetrock 897 sq ft Trace

Not Abated

Galson 1993 Shop 1 Chilled Water System Fittings

Mud Fittings 8 ftgs Positive 4 Mud fittings on fiberglass line

Not Abated

Galson 1993 Toilet Wall Sheetrock 1200 sq ft Trace Behind ceramic tile

Not Abated

Galson 1993 Mech Room Mechanical Equipment - Tank

Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Stair 1 Wall Sheetrock 800 sq ft Trace

Not Abated

Tuesday, August 17, 2010 Page 19 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 1 Ceiling Sheetrock 484 sq ft Trace Wall and ceiling considered identical

Not Abated

Galson 1993 Stair 2 Wall Sheetrock 800 sq ft Trace

Not Abated

Galson 1993 Stair 2 Ceiling Sheetrock 484 sq ft Trace Wall and ceiling considered identical

Not Abated

Galson 1993 Stair 3 Wall Sheetrock 5200 sq ft Trace

Not Abated

Galson 1993 Stair 3 Ceiling Sheetrock 1100 sq ft Trace Wall and ceiling considered identical

Not Abated

Tuesday, August 17, 2010 Page 20 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 4 Wall Sheetrock 5200 sq ft Trace

Not Abated

Galson 1993 Stair 4 Ceiling Sheetrock 1100 sq ft Trace Wall and ceiling considered identical

Not Abated

Galson 1993 Stair 5 Wall Sheetrock 800 sq ft Trace

Not Abated

Galson 1993 Stair 5 Ceiling Sheetrock 484 sq ft Trace Wall and ceiling considered identical

Not Abated

Galson 1993 Stair 6 Wall Sheetrock 800 sq ft Trace

Not Abated

Tuesday, August 17, 2010 Page 21 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Stair 6 Ceiling Sheetrock 484 sq ft Trace Wall and ceiling considered identical

Not Abated

Galson 1993 Mech Room Chilled Water System Fittings

Mud Fittings 30 ftgs Postive 2 Mud fittings on fiberglass line. Supplies hot and chilled water to building.

Not Abated

Galson 1993 Shop 1 Ceiling Fiberglass Assumed negative

Fiberglass, non-suspect ACM

Not Abated

Galson 1993 Office 2 Wall Sheetrock 3300 sq ft Trace

Not Abated

Galson 1993 Shop 1 Wall Sheetrock 2400 sq ft Trace

Not Abated

Tuesday, August 17, 2010 Page 22 of 25

Bldg No/Street Address 1080 Construction Date

Description of Building Housing Group (if applicable)

Sampled by

Sampling Date

Space ID Material Location

Sample

ID

Material Approximate Quantity

Asbestos Content

Asbestos Type

Condition Comments

Galson 1993 Roof 2 Asphalt and Gravel

As…

This is the start of the file's text. The full file is on GovTribe.