Task Order #3 5 Sep 2010
MA-SASC Task Order:
Performance Work Statement on
Building 596, 776, and 862 Dormitory Security/Surveillance Systems (362 TRS/TRR, 361 TRS/TRR, and 363 TRS/TRR, respectively)
REQUIREMENTS:
362, 361, and 363 Training Squadrons (TRS) have a requirement to install an Internet Protocol (IP) based, private video surveillance systems in Non-Prior Service (NPS) student housing areas, Buildings 596, 776, and 862, respectively. The systems shall include wired IP cameras with Power-Over Ethernet (POE) capability, network video recorders, monitoring station in Dorm 596, Dorm 776, and Dorm 862 with high definition displays capable of displaying multiple areas, and Uninterruptable Power Supply (UPS). Note that the monitoring station within each dorm shall only monitors the IP cameras installed within that dorm. The system shall have the capability to display and store high quality video images for a period of 7-14 days, 24 hour coverage (168-336 hours storage). The system shall also be expandable to accommodate future planned surveillance projects in Dorms 596, 776, and 862 that will enable maximum camera coverage in each dormitory (reference Exhibit 4). Future projects will provide full surveillance coverage in all interiors (100% of remaining hallways, entrance to every stairwell), and all exteriors (sides of buildings and courtyards). All computers, cabling and switches used in the system must meet current Air Force configuration standards. The systems within each dorm shall include initial user training and include a 1-year maintenance agreement for all installed equipment.
For this task order, these systems shall cover the facilty areas of Buildings 596, 776, and 862 as detailed below.
“Base” CLINS
The following Exterior requirements apply to Dorms 596, 776, and 862: Front, sides and rear of each building (to include “blind spots”); Outdoor common area consisting of covered picnic area and sand volleyball courts, as indicated on the Exhibits 1, 2, and 3 dorm drawings.
The following interior requirements apply to Dorms 596, 776, and 862: All entrances/exits to/from each facility (interior cameras only); commercial computer access area on Floor 1 of each facility; laundry rooms on Floor 1 of each facility; Day rooms on Floors 1 of each facility;
central hall ways on Floor 1 of each facility, to include central/lobby/atrium areas and entrances to all stairwells of each facility as indicated on Exhibits 1-3.
Contractor shall design the each dorm system based on the building drawings in Exhibit 1, 2, and
3. A site visit will be conducted in conjunction with the overall MA-SASC site visit. The date/time for this site visit will be announced on the FedBizOps website where the MA-SASC soliciation is posted. The purpose of the Dorm 596, 776, and 862 portion of this site visit is to ensure interested contractors are familiar with the physical layout of the facility and to determine where cameras and related equipment should be placed to meet or exceed requirements.
Contractor shall provide all necessary system design elements. All required equipment, software, hardware; cabling and electrical connections shall be provided and installed by the contractor.
Contractor shall be responsible for complying with any other requirements set forth in the MA- SASC contract, and for coordinating all installation permits and facility modification/construction requests through 82 Civil Engineering Squadron (DS2) and/or Base Security Forces.
“Option” CLINS
The following interior requirements apply to Dorms 596, 776, and 862: Interior: Tie into commercial computer access area on Floor 1 installed with “Base” CLINS; laundry rooms on Floors 2-4; Day rooms on Floors 2-4; central hall ways on Floors 2-4, to include central/lobby/atrium areas and entrances to all stairwells.
Exhibits
1. SAFB Building 596 Layout (362 TRS)
2. SAFB Building 776 Layout (361 TRS)
3. SAFB Building 862 Layout (363 TRS)
4. Background Paper on Proposed Dorm Surveillance Standards
5. Dorm 596 Asbestos Survey (38 pages)
6. Dorm 776 Asbestos Survey (35 pages)
7. Dorm 862 Lead Based Paint and Asbestos Statement (1 page)
Task Order Contract Line Items (CLINS):
CLIN Description (Base)
Design a turnkey, IP based, private network, video observation system for Dorms 596, 776, and 862 Sheppard AFB TX
(Base)
Provide and install all equipment and supplies for the Dorm 596, video observation system for building exterior and interior floor 1
(Base)
Provide and install all equipment and supplies for the Dorm 776, video observation system for building exterior and interior floor 1
(Base)
Provide and install all equipment and supplies for the Dorm 862, video observation system for building exterior and interior floor 1
(Base)
Provide a minimum of two training sessions to familiarize Dorms 596, 776, and 862 users with the operation and maintenance of the system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
(Option)
Provide and install all equipment and supplies for the Dorm 596, video observation system for interior floors 2-4
(Option)
Provide and install all equipment and supplies for the Dorm 776, video observation system for interior floors 2-4
(Option)
Provide and install all equipment and supplies for the Dorm 862, video observation system for interior floors 2-4
19 Aug 2010
596 1st Floor
Exhibit 1
Randell.Smith Text Box "Base" CLIN
Exhibit 1
"Option" CLIN
Exhibit 2
Exhibit 2
Exhibit 3
Exhibit 3
Gina Johnson/82 TRW/TOO/6-5884/gj/4 Aug 10
BULLET BACKGROUND PAPER
ON
82d TRW MĀ-SASC AiT DORMITORY REQUIREMENTS
INTRODUCTION: The purpose of this paper is to provide standardized requirements for cameras, public address systems, alarms, and accountability in the AiT dormitories.
DISCUSSION:
- Scope is limited to the 6 AiT dormitories, 3 dorms currently have some level of surveillance -- Need to address sister service dormitories and T-Flight
- Goal is to provide a standardized level of security in each dorm that is scalable -- Built in phases, with compatible equipment -- Integrated with other networked systems if required -- Maintainable by single contractor
- Data recorded for evidentiary purposes only, computer and data stored in a secure location -- Cameras serve as a deterrent to inappropriate actions -- No real time monitoring, due to lack of continuity, consistency, and training -- Access to data limited to Squadron Leadership and MTLs – think YouTube -- Data retained at least 5 days, more if recommended and affordable
REQUIREMENT PHASES
- Phase 1 – Minimum camera coverage in each dormitory -- Main entry, 1st floor main thoroughfares, 1st floor exits, and CQ area
- Phase 2 – Maximum camera coverage in each dormitory -- Interior – 100% of remaining hallways, entrance to every stairwell, and laundry rooms -- Exterior – sides of buildings and courtyards
- Phase 3 – Public Address System, coverage throughout dorm for mass notification -- Must comply with Unified Facility Code, integrate with Giant Voice -- Comply with Installation Warning System Plan
- Phase 4 – Alarms for unauthorized exits and emergency situations
- Phase 5 – Student Accountability – similar to DBIDS, real-time verification of occupants
EITDR – all PWS for dorm systems must contain this clause
- "Contractor will meet all government certification and accreditation requirements for information technology (IT) systems in accordance with DoDI 8510.01, DoD Information Assurance Certification and Accreditation Process (DIACAP) and AFI33-210, Air Force Certification and Accreditation (C&A) Program (AFCAP). The system must receive an Air
Exhibit 4
Gina Johnson/82 TRW/TOO/6-5884/gj/4 Aug 10
Force (AF) Approval to Operate (ATO) through the Designated Accrediting Authority (DAA) upon delivery."
COMM REQUIREMENTS
- All cabling must be coordinate with 82 CS for base standards
- IP cameras on copper CAT 6 cable, cannot exceed 300' in length
- Switches must be IPv6 compatible and CISCO
- Switches must be in a Comm cabinet and copper cables will be punched down to patch panels and then jumpered to the switch.
- Computers must have current version of FDCC 2.4
- All DoD and AF comm and industry standards for communications equipment and cable installation must be followed.
RECOMMENDATION
- Phases prioritized by Senior Leadership -- Advocate wing level funding of each phase to ensure standardization in dorms -- Phases 1 and 2 combined if funding allows -- Utilize phase approach to minimize man-hours for EITDR, project management, contracting, etc. versus one dorm at a time with actions repeated by multiple personnel, multiple dorms
Exhibit 4
SHEPPARD AFB
ASBESTOS-CONTAINING BUILDING MATERIALS
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MR01AH2-3 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
1997 1 SR Sheetrock NAD Fair
Not Abated
Galson 1993 OF01OFC1 Wall SR Sheetrock 500 sq. ft. Positive 3
Not Abated
Galson 1993 MR01AH5-6 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 MR01AH5-6 HVAC HFLEX Flexible Duct/Joint
Ass. Negative Rubber material.
Not Abated
Thursday, September 02, 2010 Page 1 of 38
Exhibit 5
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MR01AH5-6 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH5-6 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH5-6 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH5-6 Piping PI Unspecified Type
8 ft. Negative Tar wrap.
Not Abated
Galson 1993 MR01AH2-3 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 2 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC1 Floor FLVCT Vinyl Composite Tile
1100 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 MR01AH2-3 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 OF01OFC1 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 MR01AH2-3 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH2-3 Piping PI Unspecified Type
20 ft. Negative Tar wrap.
Not Abated
Thursday, September 02, 2010 Page 3 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MR01AH
MEZZ
HVAC HFLEX Flexible Duct/Joint
Ass. Negative Rubber material.
Not Abated
Galson 1993 MR01AH
MEZZ
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH
MEZZ
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH
MEZZ
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01AH
MEZZ
Duct DI Duct Insulation Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 4 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01LAUND
RY2
Ceiling CLLI Lay-in 646 sq. ft. Negative 2'x2' white, fissured.
Not Abated
Galson 1993 MI01LAUND
RY1
Ceiling CLLI Lay-in 646 sq. ft. Negative 2'x2' white, fissured.
Not Abated
Galson 1993 MR01AH2-3 HVAC HFLEX Flexible Duct/Joint
Ass. Negative Rubber material.
Not Abated
Galson 1993 OF01OFC3 Wall SR Sheetrock 750 sq. ft. Positive 3
Not Abated
Galson 1993 OF01OFC4 Ceiling SR Sheetrock 1200 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Thursday, September 02, 2010 Page 5 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC4 Wall SR Sheetrock 750 sq. ft. Positive 3
Not Abated
Galson 1993 OF01OFC3 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 OF01OFC3 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFC3 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFC3 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 6 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC3 Floor FLVCT Vinyl Composite Tile
192 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 OF01OFC3 Ceiling CLLI Lay-in 544 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 OF01OFC3 Ceiling CLLI Lay-in 1600 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 OF01OFC1 Ceiling CLLI Lay-in 1000 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 OF01OFC3 Ceiling SR Sheetrock 1200 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Thursday, September 02, 2010 Page 7 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 LO01BREA K2
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 OF01OFC2 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFC2 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFC2 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFC2 Floor FLVCT Vinyl Composite Tile
1100 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Thursday, September 02, 2010 Page 8 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC2 Ceiling CLLI Lay-in 300 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 OF01OFC2 Ceiling CLLI Lay-in 700 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 OF01OFC2 Wall SR Sheetrock 500 sq. ft. Positive 3
Not Abated
Galson 1993 OF01OFC1 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFC1 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 9 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC3 Ceiling PLST Plaster 24 sq. ft. Negative
Not Abated
Galson 1993 BR01BOIL Mech Equipment MTK Tank Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 DR01DININ G
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 DR01DININ G
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 DR01DININ G
Ceiling CLLI Lay-in 7000 sq. ft. Negative 2'x2' white, fissured.
Not Abated
Thursday, September 02, 2010 Page 10 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 DR01DININ G
Wall SR Sheetrock 6000 sq. ft. Positive 3
Not Abated
Galson 1993 CS01CRAW L
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 CS01CRAW L
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 BR01BOIL Mech Equipment MFLUE Flue Ass. Negative Fiberglass, non-suspect ACM. Under metal jacket.
Not Abated
Galson 1993 BR01BOIL Mech Equipment MBLR Boiler Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Thursday, September 02, 2010 Page 11 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 BR01BOIL Mech Equipment MEQIN Insulating Material
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 LO01BREA K2
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 BR01BOIL Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 ER01ELEC
TRIC
Ceiling SR Sheetrock 268 sq. ft. Positive 4
Not Abated
Galson 1993 BR01BOIL Piping PI Unspecified Type
1 ft. Negative Tar wrap.
Not Abated
Thursday, September 02, 2010 Page 12 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 BR01BOIL Fitting FIHW Heating Hot Water
18 ftgs. Negative Mud fittings on fiberglass line.
Not Abated
Galson 1993 BR01BOIL Ceiling SR Sheetrock 1500 sq. ft. Positive 3
Not Abated
1997 7 SR Sheetrock NAD Fair
Not Abated
1997 6 FT/M Floor Tile/Mastic
NAD Fair <1% Chrysotile in sample, 5% Chrysotile in black mastic.
Not Abated
1997 5 FT/M Floor Tile/Mastic
NAD Fair <1% Chrysotile in sample, 10% Chrysotile in black mastic.
Not Abated
Thursday, September 02, 2010 Page 13 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
1997 4 FT/M Floor Tile/Mastic
NAD Chrysotile Fair <1% Chrysotile in sample, 10% Chrysotile in black mastic.
Not Abated
1997 3 SR Sheetrock NAD Fair
Not Abated
1997 2 SR Sheetrock NAD Fair
Not Abated
Galson 1993 BR01BOIL Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 KI01KITCH N
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 14 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC4 Ceiling CLLI Lay-in 544 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 LO01BREA K2
Ceiling CLLI Lay-in 720 sq. ft. Negative 2'x2' white, fissured.
Not Abated
Galson 1993 LO01BREA K1
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 LO01BREA K1
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 LO01BREA K1
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Thursday, September 02, 2010 Page 15 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 LO01BREA K1
Ceiling CLLI Lay-in 720 sq. ft. Negative 2'x2' white, fissured.
Not Abated
Galson 1993 KI01WASH HVAC HFLEX Flexible Duct/Joint
Ass. Negative Rubber material.
Not Abated
Galson 1993 KI01WASH Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 KI01WASH Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 DR01DININ G
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Thursday, September 02, 2010 Page 16 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 KI01KITCH N
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 DR01DININ G
Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 KI01KITCH N
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 KI01KITCH N
Floor FLVCT Vinyl Composite Tile
925 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 KI01KITCH N
Ceiling PLST Plaster 2400 sq. ft. Positive
Not Abated
Thursday, September 02, 2010 Page 17 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 KI01KITCH N
Ceiling SR Sheetrock 495 sq. ft. Positive 3
Not Abated
Galson 1993 FO01LOBB Y
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 FO01LOBB Y
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 FO01LOBB Y
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 FO01LOBB Y
Floor FLVCT Vinyl Composite Tile
2000 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Thursday, September 02, 2010 Page 18 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 FO01LOBB Y
Ceiling SR Sheetrock 2000 sq. ft. Positive 3
Not Abated
Galson 1993 LO01BREA K2
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 KI01WASH Ceiling PLST Plaster 648 sq. ft. Negative
Not Abated
Galson 1993 RS02LIV6 Ceiling SR Sheetrock 5500 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS02LIV7 Ceiling PLST Plaster 546 sq. ft. Negative
Not Abated
Thursday, September 02, 2010 Page 19 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV7 Ceiling SR Sheetrock 5500 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS02LIV7 Wall SR Sheetrock 26000 sq. ft. Positive 2
Not Abated
Galson 1993 RS02LIV6 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 RS02LIV6 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV6 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 20 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV6 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV6 Floor FLVCT Vinyl Composite Tile
4400 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS02LIV6 Ceiling CLLI Lay-in 13000 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 RS02LIV5 Ceiling SR Sheetrock 5500 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS02LIV6 Ceiling PLST Plaster 546 sq. ft. Negative
Not Abated
Thursday, September 02, 2010 Page 21 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV7 Floor FLVCT Vinyl Composite Tile
4400 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS02LIV6 Wall SR Sheetrock 26000 sq. ft. Positive 2
Not Abated
Galson 1993 RS02LIV5 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 RS02LIV5 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV5 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 22 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV5 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV5 Floor FLVCT Vinyl Composite Tile
4400 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS02LIV5 Ceiling CLLI Lay-in 13000 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 RS02LIV5 Ceiling CLLI Lay-in 3700 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 OF01OFC4 Ceiling PLST Plaster 24 sq. ft. Negative
Not Abated
Thursday, September 02, 2010 Page 23 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV6 Ceiling CLLI Lay-in 3700 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS02LIV8 Floor FLVCT Vinyl Composite Tile
4400 sq. ft. Ass. Positive 7 2'x4' white fissured pattern.
Not Abated
Galson 1993 TO01TOILT
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 TO01TOILT
Ceiling PLST Plaster 344 sq. ft. Negative
Not Abated
Galson 1993 TO01TOILT
Ceiling SR Sheetrock 56 sq. ft. Positive 3
Not Abated
Thursday, September 02, 2010 Page 24 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 TO01TOILT
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 TO01TOILT
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 TO01TOILT
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 TO01TOILT
Ceiling SR Sheetrock 146 sq. ft. Positive 3
Not Abated
Galson 1993 RS02LIV8 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 25 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV8 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV7 Ceiling CLLI Lay-in 3700 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS02LIV8 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV7 Ceiling CLLI Lay-in 13000 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 RS02LIV8 Ceiling CLLI Lay-in 13000 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Thursday, September 02, 2010 Page 26 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV8 Ceiling CLLI Lay-in 3700 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS02LIV8 Ceiling PLST Plaster 546 sq. ft. Negative
Not Abated
Galson 1993 RS02LIV8 Ceiling SR Sheetrock 5500 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS02LIV8 Wall SR Sheetrock 26000 sq. ft. Positive 2
Not Abated
Galson 1993 RS02LIV7 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 27 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV7 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV7 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV7 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS02LIV5 Wall SR Sheetrock 26000 sq. ft. Positive 2
Not Abated
Galson 1993 RS02LIV8 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 28 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV1 Ceiling CLLI Lay-in 4600 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 RS01LIV2 Floor FLVCT Vinyl Composite Tile
1500 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS01LIV2 Ceiling CLLI Lay-in 4600 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Galson 1993 RS01LIV2 Ceiling CLLI Lay-in 5600 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS01LIV2 Ceiling PLST Plaster 192 sq. ft. Negative
Not Abated
Thursday, September 02, 2010 Page 29 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV2 Ceiling SR Sheetrock 1900 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS01LIV2 Wall SR Sheetrock 9000 sq. ft. Positive 2
Not Abated
Galson 1993 RS01LIV1 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Galson 1993 RS01LIV1 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV1 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Thursday, September 02, 2010 Page 30 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS02LIV5 Ceiling PLST Plaster 546 sq. ft. Negative
Not Abated
Galson 1993 RS01LIV1 Floor FLVCT Vinyl Composite Tile
1500 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS01LIV2 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV1 Ceiling CLLI Lay-in 5600 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS01LIV1 Ceiling PLST Plaster 192 sq. ft. Negative
Not Abated
Thursday, September 02, 2010 Page 31 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV1 Ceiling SR Sheetrock 1900 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS01LIV1 Wall SR Sheetrock 9000 sq. ft. Positive 2
Not Abated
Galson 1993 RF02ROOF
Roof RFAG Asphalt and Gravel
32000 sq. ft. Ass. Positive 7
Not Abated
Galson 1993 RF02ROOF
Roof RFAG Asphalt and Gravel
32000 sq. ft. Ass. Positive 7
Not Abated
Galson 1993 RF01ROOF
Roof RFAG Asphalt and Gravel
20000 sq. ft. Ass. Positive 7
Not Abated
Thursday, September 02, 2010 Page 32 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC4 Floor FLVCT Vinyl Composite Tile
192 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 TO01TOILT
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV1 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV3 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV4 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 33 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV4 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV4 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV4 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV4 Floor FLVCT Vinyl Composite Tile
1500 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS01LIV4 Ceiling CLLI Lay-in 4600 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Thursday, September 02, 2010 Page 34 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV4 Ceiling CLLI Lay-in 5600 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS01LIV4 Ceiling PLST Plaster 192 sq. ft. Negative
Not Abated
Galson 1993 RS01LIV4 Ceiling SR Sheetrock 1900 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS01LIV2 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV3 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 35 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV2 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV3 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV3 Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 RS01LIV3 Floor FLVCT Vinyl Composite Tile
1500 sq. ft. Ass. Positive 7 1'x1' gray with gray specks, 1'x1' white with gray specks.
Not Abated
Galson 1993 RS01LIV3 Ceiling CLLI Lay-in 4600 sq. ft. Negative 2'x4' white pinhole pattern.
Not Abated
Thursday, September 02, 2010 Page 36 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 RS01LIV3 Ceiling CLLI Lay-in 5600 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS01LIV3 Ceiling PLST Plaster 192 sq. ft. Negative
Not Abated
Galson 1993 RS01LIV3 Ceiling SR Sheetrock 1900 sq. ft. Positive 3 Wall and ceiling material considered identical.
Not Abated
Galson 1993 RS01LIV3 Wall SR Sheetrock 9000 sq. ft. Positive 2
Not Abated
Galson 1993 RS01LIV2 Piping PI Unspecified Type
Ass. Negative Foam rubber. Non-suspect
ACM.
Not Abated
Thursday, September 02, 2010 Page 37 of 38
Bldg No/Street Address 596 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 OF01OFC4 Ceiling CLLI Lay-in 1600 sq. ft. Negative 2'x4' white fissured pattern.
Not Abated
Galson 1993 RS01LIV4 Wall SR Sheetrock 9000 sq. ft. Positive 2
Not Abated
Thursday, September 02, 2010 Page 38 of 38
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01LAUN2 Ceiling SR Sheetrock 360 sq. ft. Positive 2
Not Abated
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Tuesday, August 17, 2010 Page 1 of 35
Exhibit 6
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MI01LAUN2 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 MI01LAUN2 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 OF01OFF1 Wall SR Sheetrock 348 sq. ft. Positive 2
Not Abated
Tuesday, August 17, 2010 Page 2 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01LAUN2 Ceiling CLLI Lay-in 680 sq. ft. Negative 2'x2' white, fissured and perforated.
Not Abated
Galson 1993 MR01MECH
Ceiling SR Sheetrock 254 sq. ft. Positive 1
Not Abated
Galson 1993 MI01LAUN1 Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 MI01LAUN1 Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 MI01LAUN1 Floor FLVCT Vinyl Composite Tile
680 sq. ft. Ass. Positive 7 1'x1' white with gray.
Not Abated
Tuesday, August 17, 2010 Page 3 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01LAUN1 Ceiling CLLI Lay-in 680 sq. ft. Negative 2'x2' white, fissured and perforated.
Not Abated
Galson 1993 MI01LAUN1 Ceiling SR Sheetrock 420 sq. ft. Positive 2
Not Abated
Galson 1993 KI01KIT Floor FLVCT Vinyl Composite Tile
1500 sq. ft. Ass. Positive 7 1'x1' red brick pattern - 80%, 1'x1' brown - 20%.
Not Abated
Galson 1993 KI01KIT Fitting FIDW Domestic Water 4 ftgs. Negative Mud fittings on fiberglass line.
Not Abated
Galson 1993 KI01KIT Ceiling CLLI Lay-in 5600 sq. ft. Negative 2'x2' white textured pattern.
Not Abated
Tuesday, August 17, 2010 Page 4 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01LAUN2 Floor FLVCS Vinyl Composite Sheet
680 sq. ft. Trace Tan with raised brown circles.
Not Abated
Galson 1993 MR01MECH
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
1997 1 TSI Thermal System Insulation
NAD Fair
Not Abated
Galson 1993 OF01OFF1 Ceiling PLST Plaster 112 sq. ft. Negative Wall and ceiling material considered identical.
Not Abated
Galson 1993 OF01OFF1 Wall PLST Plaster 848 sq. ft. Negative
Not Abated
Tuesday, August 17, 2010 Page 5 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MR01MECH
HVAC HFLEX Flexible Duct/Joint
Ass. Negative Foam rubber, non-suspect
ACM.
Not Abated
Galson 1993 MR01MECH
Piping PI Unspecified Type
Ass. Negative
Not Abated
Galson 1993 MR01MECH
Fitting FIDW Domestic Water 8 ftgs. Negative Mud fittings on fiberglass line.
Not Abated
Galson 1993 MR01MECH
Mech Equipment MDHWTK Domestic Hot Water Tank
392 sq. ft. Trace
Not Abated
Galson 1993 MR01MECH
Fitting FIHW Heating Hot Water
13 ftgs. Negative Mud fittings on fiberglass line.
Not Abated
Tuesday, August 17, 2010 Page 6 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MR01MECH
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MI01STAIR
Ceiling SR Sheetrock 196 sq. ft. Positive 2
Not Abated
Galson 1993 MR01MECH
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01MECH
Fitting FITAR Tar Wrap On Pipe
3 ftgs. Negative
Not Abated
Tuesday, August 17, 2010 Page 7 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MR01MECH
Ceiling SR Sheetrock 254 sq. ft. Positive 1
Not Abated
Galson 1993 MR01MECH
HVAC HFLEX Flexible Duct/Joint
Ass. Negative Rubber material.
Not Abated
Galson 1993 MR01MECH
Fitting FI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01MECH
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Galson 1993 MR01MECH
Duct DI Duct Insulation Ass. Negative Fiberglass, non-suspect ACM.
Not Abated
Tuesday, August 17, 2010 Page 8 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 MR01MECH
Fitting FITAR Tar Wrap On Pipe
3 ftgs. Negative
Not Abated
Galson 1993 KI01KIT Ceiling SR Sheetrock 840 sq. ft. Positive 2 Wall and ceiling material considered identical.
Not Abated
Galson 1993 MR01MECH
HVAC HFLEX Flexible Duct/Joint
Ass. Negative Rubber material.
Not Abated
1997 4 SR Sheetrock NAD Fair
Not Abated
Galson 1993 KI01KIT Ceiling CLLI Lay-in 1800 sq. ft. Negative 2'x2' white, fissured and perforated.
Not Abated
Tuesday, August 17, 2010 Page 9 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
2000 1 Front Office FT/M Floor Tile/Mastic
10% Chrysotile Fair Black mastic. Green FT is 3%.
Not Abated
2000 3 SR Sheetrock NAD Fair Brown/white.
Not Abated
2000 2 SR Sheetrock NAD Fair Brown/white.
Not Abated
2000 1 SR Sheetrock NAD Fair Brown/white.
Not Abated
1997 9 CT Ceiling Tile NAD Fair
Not Abated
Tuesday, August 17, 2010 Page 10 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
1997 8 CT Ceiling Tile NAD Fair
Not Abated
1997 7 CT Ceiling Tile NAD Fair
Not Abated
2000 3 Front Office FT/M Floor Tile/Mastic
10% Chrysotile Fair Black mastic. Green FT is 3%.
Not Abated
1997 5 SR Sheetrock NAD Fair
Not Abated
2000 1 Main Mech Rm, Water Tank
IM Insulating Material
40% Chrysotile Fair White mud insulation.
Not Abated
Tuesday, August 17, 2010 Page 11 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
1997 3 FT Floor 3% Fair
Not Abated
1997 2 FT Floor 2% Fair
Not Abated
1997 1 FT Floor 2% Fair
Not Abated
1997 7 TSI Thermal System Insulation
30% Fair
Not Abated
1997 6 TSI Thermal System Insulation
NAD Fair
Not Abated
Tuesday, August 17, 2010 Page 12 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
1997 5 TSI Thermal System Insulation
NAD Fair
Not Abated
1997 4 TSI Thermal System Insulation
30% Fair
Not Abated
1997 3 TSI Thermal System Insulation
NAD Fair
Not Abated
1997 2 TSI Thermal System Insulation
NAD Fair
Not Abated
1997 6 SR Sheetrock NAD Fair
Not Abated
Tuesday, August 17, 2010 Page 13 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
2000 7 IM Insulating Material
NAD Fair White mudded elbow.
Not Abated
Galson 1993 OF01OFF1 Ceiling SR Sheetrock 664 sq. ft. Positive 2 Wall and ceiling material considered identical.
Not Abated
Galson 1993 FO01FOYE R
Ceiling CLLI Lay-in 2500 sq. ft. Negative 2'x2' white, fissured and perforated.
Not Abated
Galson 1993 CS0BCRAW
LSPACE
Piping PI Unspecified Type
Ass. Negative Fiberglass, non-suspect ACM. Above ceiling.
Not Abated
Galson 1993 CS0BCRAW
LSPACE
Fitting FIDW Domestic Water 4 ftgs. Negative Mud fittings on fiberglass line.
Not Abated
Tuesday, August 17, 2010 Page 14 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
Galson 1993 CS0BCRAW
LSPACE
Fitting FIHW Heating Hot Water
4 ftgs. Negative Mud fittings on fiberglass line.
Not Abated
Galson 1993 CM01COMP
UTER
Floor FLVCT Vinyl Composite Tile
480 sq. ft. Ass. Positive 7 1'x1' white gray.
Not Abated
Galson 1993 CM01COMP
UTER
Ceiling CLLI Lay-in 760 sq. ft. Negative 2'x4' white large fissured pattern.
Not Abated
Galson 1993 CM01COMP
UTER
Wall SR Sheetrock 80 sq. ft. Positive 2
Not Abated
2000 2 Front Office FT/M Floor Tile/Mastic
10% Chrysotile Fair Black mastic. Green FT is 3%.
Not Abated
Tuesday, August 17, 2010 Page 15 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
2001 1 Hot Water Gen TSI Thermal System Insulation
NAD Fair Gray.
Not Abated
Galson 1993 KI01KIT Wall SR Sheetrock 4300 sq. ft. Positive 2
Not Abated
2000 6 IM Insulating Material
NAD Fair Tan insulation.
Not Abated
2000 5 IM Insulating Material
NAD Fair Tan insulation.
Not Abated
2000 4 IM Insulating Material
45% Chrysotile Fair Black seal.
Not Abated
Tuesday, August 17, 2010 Page 16 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
2000 3 IM Insulating Material
NAD Fair Tan mudded elbow.
Not Abated
2000 2 IM Insulating Material
20% Chrysotile Fair White stack.
Not Abated
2000 1 IM Insulating Material
15% Chrysotile Fair White stack.
Not Abated
2000 4 Main Mech Rm, On Valve.
IM Insulating Material
NAD Fair Gray mud insulation.
Not Abated
2000 3 Main Mech Rm, On Valve.
IM Insulating Material
NAD Fair Gray mud insulation.
Not Abated
Tuesday, August 17, 2010 Page 17 of 35
Bldg No/Street Address 776 Construction Date
Description of Building Housing Group (if applicable)
Sampled by
Sampling Date
Space ID Material Location
Sample
ID
Material Approximate Quantity
Asbestos Content
Asbestos Type
Condition Comments
2000 2 Main Mech Rm, Water Tank
IM Insulating Material
NAD Fair White mud insulation.
Not Abated
2001 2 Hot Water Gen TSI Thermal System Insulation
30% Chrysotile Fair Gray.
Not Abated
Galson 1993 RS01RES4 Fitting FI Unspecified Type
Ass.…