Task Order # 6 3 Sep 2010
MA-SASC Task Order:
Performance Work Statement on
Building 280, 527, 530 & 1670 Electronic Door Lock (RFID) System
(82 CES/CEHD)
REQUIREMENTS:
82 CES/CEHD has a requirement to install wireless networked electronic door locking systems in buildings 280, 527, 530 and 1670. The equipment used to install the system shall be radio frequency identification device (RFID). The system shall have the capability to program RFID cards to provide access or to deny access to dormitory entrance doors. The RFID cards need to have the ability to be updated, restricted or deleted remotely. RFID cards need to have ability to be recycled. The dormitory locks shall have the ability to open doors mechanically using conventional keys. Door room locks and deadbolt must meet ANSI Grade 1 standards. All electronics, cabling and switches used in the system must meet current Air Force configuration standards IAW AFI 31-101, "Air Force Physical Security Program. The system shall include initial user training and include a minimum 1-year maintenance agreement for all installed equipment.
Installation
This system shall cover the facility areas as detailed below.
Exterior: All entrance doors in Bldg 280, 527, 530 and 1670 will have mortise or cylindrical locks installed depending on the current door’s lock style.
Interior: All entrance doors in Bldg 280, 527, 530 and 1670 will have mortise or cylindrical locks installed depending on the current door’s lock style. All electronic control equipment will be installed Buildings 373, 530 and 1670.
The contractor shall design the system based on the building diagram in the Exhibits 1-4 building layouts.
The contractor shall provide all necessary system design elements. All required equipment, software, hardware; cabling and electrical connections shall be provided and installed by the contractor.
Task Order # 6 3 Sep 2010
The contractor shall be responsible for coordinating all installation permits and facility modification/construction requests through 82d Civil Engineering Squadron (DS2), 82d Security Forces Squadron, and 82d Civil Engineering Squadron Fire Department.
Exhibits
1. 82 CES/CEHD SAFB Building 280 Layout
2. 82 CES/CEHD SAFB Building 527 Layout
3. 82 CES/CEHD SAFB Building 530 Layout
4. 82 CES/CEHD SAFB Building 1670 Layout
Task Order Contract Line Items (CLINS):
CLIN Description 0001 Design an electronic door lock system using
RFID technology for Bldg 280, 527, 530 and 1670 to be controlled from 373, 530 and 1670.
0002 Provide and install all equipment and supplies for the electronic door lock (RFID) system.
0003 Provide a minimum of two training sessions to familiarize users with the operation and maintenance of the system and a minimum of two hard and soft copies of any manufacturer’s information on the installed system
Exhibit 1
Exhibit 1
Permanent Party- First, Second, and Third Floors Building 527
N
A
Exhibit 2
Dorm Managers Office #119 Janitor #124
BUILDING 1670
1ST FLOOR QUAD 102-110
Exhibit 4
STORAGE
ROOM #219
2ND FLOOR QUAD 202-210
Mechanical Room
3RD FLOOR QUAD 302-310
Roof Access
4TH FLOOR QUAD 402-410
File details come from the government source that posted it. Updated .