DRAFT
VANCE AFB
FIRE EMERGENCY SERVICES
18-1-1
SECTION 18-1
18. FIRE EMERGENCY SERVICES (FES)
18.1. DESCRIPTION OF SERVICES: The Fire Emergency Service (FES) activity is responsible for providing oversight and management of all fire protection and fire prevention services at Vance Air Force Base (AFB) and any attached or related properties under the control of Vance AFB on a 24 hours, 7 days a week basis and Kegelman Auxiliary Airfield (AAF) during flying operations. The mission of the Fire Emergency Services is to provide fire protection and prevention services to minimize negative consequences of emergency incidents.
Services include responding to and mitigating releases of hazardous materials (HazMat) for example toxic industrial chemicals (TIC), toxic industrial materials (TIM), and chemical, biological, radiological, nuclear and high yield explosives (CBRNE) resulting from accident, natural causes, or intentional use as a weapon of mass destruction (WMD); fires that endanger people, property, or the environment regardless of the property involved (wildland, equipment, buildings, aircraft, etc.); fires in nearby DOD and federal agency facilities in the event normal FES are inhibited; persons trapped or otherwise unable to escape a dangerous situation; pre-hospital emergency medical care (non-transport); and intervention at other emergency situations such as natural or manmade disasters that threaten life, property or the environment. The FES activity is broadly categorized as (1) Management and Administration; (2) Training; (3) Fire Prevention; and (4) Operations. The FES management staff provides administration, communication, oversight and supervision of FES activities. FES management staff consists of the Fire Chief, a Deputy Fire Chief, Assistant Fire Chief(s) of Operations (one per shift), one Assistant Fire Chief of Training, one Assistant Fire Chief of Health and Safety, and one Assistant Fire Chief of Fire Prevention. The administrative staff includes a Fire ECC Supervisor and emergency communications center (ECC) dispatchers.
18.1.2. The Service Provider (SP) shall:
18.1.2.1. FIRE EMERGENCY SERVICES (FES): Provide FES Management and Administration Services, FES Training Services, Fire Prevention Services, FES Fire and Rescue Emergency Response Services, HazMat Mitigation Services, pre-hospital Emergency Medical Services, Emergency Management Services, intervention at other emergency situations (such as natural or manmade disasters that threaten life, property or the environment), and associated tasks for Vance AFB and any attached or related properties under the control of Vance AFB on a 24 hour / 7 days a week basis and Kegelman AAF during flying operations. Perform all duties associated with fire protection and prevention. Provide a fully trained and certified staff. Ensure quality work performance in accordance with (IAW) applicable standards and guidelines.
Comply with most current versions of Department of Defense (DoD), Air Force (AF), higher headquarters (HHQ), Occupational Safety and Health Administration (OSHA), Code of Federal Regulations (CFR) directives, instructions, regulations, and supplements, the National Fire Codes published by the National Fire Protection Association (NFPA) to include Technical Implementation Guides (TIGs) and the Fire Emergency Services Assessment Plan (FESAP), and all applicable state and local directives, instructions, regulations, and or supplements. Provide continued service during periods of labor unrest to include for example walkouts, work slowdowns, and strikes. Create and maintain a strike plan that sets forth procedures to follow
18-1-2 that will ensure continuous un-interrupted Fire Emergency Services are provided. Submit the strike plan to the Contracting Officer Representative (COR) and the Contracting Officer (CO) for review and approval 30 days after contract award. Provide continued service 24 hours a day, 7 days a week throughout a crisis declared by the National Command Authority. Ensure qualified personnel are available during a crisis for any operational emergency IAW current DOD, AF, and higher headquarters guidance. Submit a crisis management plan and an essential personnel list to the COR and CO within 10 days after contract start date. The essential personnel list shall contain the individual's name, duty title, security clearance, home address, home phone number, cell phone number, and beeper number. This essential personnel list shall be updated as required and at-least semi-annually. Comply with and implement the AF fire and emergency services and higher headquarter fire and emergency services fire reporting to National Fire Incident Reporting System (NFIRS). Populate, maintain, update, generate, and manage data and reports from government designated database(s) system to include for example Interim Work Information Management System (IWIMS), Automated Civil Engineer System-Fire Department (ACES-FD), Civil Engineer Material Acquisition System (CEMAS), other data collection systems, and government designated replacement systems, for example NexGen/Tririga, as required by higher headquarters. Utilize database systems to the fullest extent. Provide data and reports as requested. Develop and implement a self-inspection program to address the areas outlined in the current Higher Headquarters Inspector General (IG) Inspection Guidance, to include the FESAP.
Maintain compliance with the most current edition of the FESAP. Provide fire protection and investigation services for DoD and federal agency interests in the local area when needed.
Maintain mutual aid support agreements IAW higher headquarter instructions. Additionally, partner with the base and local communities in order to improve the quality of Fire Protection Programs and services offered to customers. Provide all staff uniforms and ensure uniforms are maintained in a clean and professional manner. Provide 24 hours a day, 7 days a week Emergency Communication Center (ECC) operations. Provide qualified and certified personnel for FES/ECC dispatch services 24 hours a day, 7 days a week. Conduct and participate in ad hoc meetings, teleconferences, Defense Connect Online (DCO) meetings, and information exchange with base and higher headquarters staff. Participate in the Confined Space Program, Wing Inspection Team, Emergency Management Working Group, HazMat Planning Board, and meetings to address operational concerns. The fire emergency services functions include but not limited to: fire protection program management; fire protection operational management;
incident management; fire emergency response; technical rescue; confined space rescue;
offensive hazardous material response mitigation at the Hazmat Technician level; emergency medical response; pre-incident planning; equipment and vehicle management; depot level vehicle program participant; mutual aid program participant; contingency response force participation; fire prevention support; community fire prevention education; review design drawings; acceptance testing of fire alarm/fire suppression systems; fire investigation; welding, cutting and brazing permits; open fame permits; fire prevention inspections; financial management; and training and documentation.
18.1.2.2. FIRE EMERGENCY SERVICES (FES) MANAGEMENT: Establish and maintain FES programs to ensure the protection of the Vance AFB community, personnel, property and the environment. Implement a firefighter safety program to ensure firefighter safety IAW applicable standards and guidelines. Provide FES management support personnel consisting of a Fire Chief, a Deputy Fire Chief, Assistant Fire Chief(s) of Operations (one per shift), one
18-1-3
Assistant Fire Chief of Training, one Assistant Fire Chief of Health and Safety Officer, and one Assistant Fire Chief of Fire Prevention and administrative support personnel consisting Fire Emergency Communications Center (ECC) dispatchers and a Fire ECC Supervisor. ECC personnel shall not be included in the minimum staffing for Fire Operations. Also provide Fire Prevention support personnel consisting of two (2) Fire Inspectors. Provide a minimum of 13 personnel for Vance AFB Fire Operations (an Assistant Chief of Operations and 12 firefighters) per 24 hour period. This includes a minimum of seven DoD certified Hazardous Materials (HazMat) Technicians per 24 hour period. Additionally, provide Fire Protection/Emergency Services for Kegelman AAF during flying operations; ensure Kegelman AAF Fire Protection/Emergency Services is staffed and operationally capable Monday through Friday 30 minutes prior to start of flying operations in the Kegelman AAF airspace area of responsibility and ending 30 minutes after flying operations cease, and on weekends as required to support flying operations beginning 30 minutes prior to start of flying operations and ending 30 minutes after flying operations cease. Minimum FES staffing for Kegelman AAF is four (a Station Chief and three fire fighters). Conduct and participate in ad hoc meetings, teleconferences, Defense Connect Online (DCO) meetings, and information exchange with base and higher headquarters staff.
18.1.2.2.1. FES ASSESSMENT PROGRAM (FESAP): Utilize the most current version of the FESAP located on the AF FES Community of Practice (CoP) or next generation replacement as the standard inspection checklist for the annual self inspection program, Command Staff Assistance Visits (SAV), and Higher Headquarters Inspector General Inspections. Update the FESAP semi-annually and provide a copy to the Command Fire Chief on an annual basis and as requested.
18.1.2.2.2. FIREFIGHTER FITNESS AND WELLNESS (FFW) PROGRAM: Implement a FFW Program. The program shall be IAW OSHA and NFPA requirements. All AF firefighters whose positions require participation in emergency incident operations, to include firefighters with 56/60-hour work schedules will participate in the program. Individuals not physically capable of performing essential job functions shall be referred to a physician for a fitness-for-duty evaluation. Members disqualified shall be immediately removed from firefighting duties.
18.1.2.2.3. EMPLOYEE APPEARANCE: Ensure employees present a neat appearance. Fire protection uniforms shall be easily recognized and uniform throughout the department.
18.1.2.2.4. MEETINGS: Attend all meetings concerning on-base and off-base activities that involve FES interest, support and when representation is requested by another appropriate activity (for example work order review committee). Brief the installation leadership and government officials as required.
18.1.2.2.5. PUBLICATIONS MANAGEMENT: Review and update Fire Protection publications annually. Submit revised publications to include Standard Operating Instructions/Guides/ Procedures, Management Plans and the Vance AFB supplement to AFI 32-2001 to the Government for approval. Maintain files, forms, documents and publications as required to comply with the most current versions of DoD, AF, higher headquarters, OSHA, CFR directives, instructions, regulations, supplements, all federal, state, and local directives, instructions, 18-1-4 regulations, supplements, and National Fire Codes and recommendations published by the NFPA to include TIGs. Develop and implement efficient processes for accomplishing outputs without sacrificing quality standards. Provide the Government access to all files, forms, documents, and publications and electronic media at all times.
18.1.2.2.6. MUTUAL AID AGREEMENTS: Review and honor current mutual aid agreements (MAA) with the local civilian community. Actively participate in the MAA program. Maintain a copy of these agreements. Mutual aid agreements that are reviewed and require updating will be accomplished IAW higher headquarters standards. All MAAs shall be approved by the installation commander. Coordinate with local agencies to become familiar with local agency incident management system used by each emergency response agency. Obtain copies of local community fire department emergency response plans for high hazard areas within the mutual aid response area. Perform an annual survey of the MAA response areas to ensure a full understanding of potential hazards Provide a qualified Incident Safety Officer at every MAA incident supported with full authority to alter or suspend Fire/Rescue Emergency Operations, and authority to suspend Vance AFB FES participation in emergency operations.
18.1.2.2.7. EMERGENCY COMMUNICATION CENTER (ECC): Process and dispatch all request for emergency assistance from voice and automated receiving devices, process and forward routine administrative calls and notifications 24 hours a day, 7 days a week with a qualified and certified ECC operator. The ECC operator shall maintain alertness and shall not leave the ECC unless properly relieved by a certified and qualified operator. In the event the Emergency Communications Center is impaired or out of service for any reason, transfer operations to a pre-designated alternate location. Maintain instructions, plans, and required documentation required for ECC operations in each ECC location, for example all pre-incident/pre-fire plans, required maps, explosive licenses, Management Plans and Standard Operating Instructions/Guides/Procedures, routine checklists and Emergency Response Checklists. ECC instructions, plans, and required documentation shall be current at all times.
Maintain all required activity and service logs, for example daily activity log, emergency response log, service outage log, and welding permit log in ACES-FD and government designated data management systems as required, and government designated replacement systems. The ECC Supervisor shall report to the Deputy Fire Chief. The Deputy Fire Chief shall manage the ECC.
18.1.2.2.8. FES HEALTH AND SAFETY PROGRAM(S): The Assistant Chief of Health and Safety shall be assigned as FES Health and Safety Officer. Implement and maintain FES Health and Safety Programs IAW applicable standards and guidelines.
18.1.2.3. FES TRAINING: Establish a program that encompasses certification and proficiency training requirements. All members shall be certified IAW DoD directives and the Fire and Emergency Services Certification System (FESCS). Participate in the Fire Emergency Services Credentialing (FESCRE) program. Record and maintain all FES proficiency and certification training in ACES-FD and government designated system(s), for example NexGen/Tririga.
Ensure all FES personnel meet and maintain the minimum training requirements in the AF Fire Emergency Services Training Program (FESTP) as outlined in the FESAP. Conduct and participate in ad hoc meetings, teleconferences, Defense Connect Online (DCO) meetings, and
18-1-5 information exchange with base and higher headquarters staff. Utilize government computer based testing tool, for example Certification Testing (CERTEST) and designated replacement software program(s) and associated procedural guide.
18.1.2.3.1. AIRCRAFT/STRUCTURAL LIVE-FIRE TRAINING FACILITIES: Maintain and operate live-fire training facilities IAW most current standards and government technical directives. Any modifications to live fire trainers shall be coordinated and approved by higher headquarters. All live-fire training shall be conducted IAW the most current standards and guidelines. Live fire training proficiencies shall be IAW the most current NFPA Standards.
18.1.2.3.2. Deleted
18.1.2.4. FIRE PREVENTION: Implement all fire prevention program elements for example facility plan reviews, identification of fire hazards in facilities, code enforcement, and fire safety education. Identify and monitor status of fire safety hazards and Fire Safety Deficiencies (FSD).
Aid the development and annual review of facility fire prevention programs and facility pre-fire plans to facilitate early intervention at fire events. Conduct and participate in ad hoc meetings, teleconferences, Defense Connect Online (DCO) meetings, and information exchange with base and higher headquarters staff. Provide fire safety training to the entire base populace.
18.1.2.4.1. PREVENTION: Conduct facility fire prevention inspections at least annually for all facilities or more frequently if required or directed. Inspect commercial kitchen hood and duct systems as required. Identify, document, and report fire safety hazards (conditions that can cause a fire) and FSDs (conditions that cannot directly cause a fire but will increase risk to personnel or property if a fire occurs). Manage fire safety hazards and FSDs IAW government directives. Use AF Form 1487, Fire Prevention Visit Report, or government approved automated product to document and report fire safety hazards and FSDs to commanders. Enter fire prevention visit reports into ACES-FD and government designated replacement system(s), for example NexGen/Tririga. Use AF Form 218, Facility Fire Prevention and Protection Record, or government approved automated product as an inspection checklist and to record results of facility inspections. Record facility inspection in ACES-FD and government designated replacement system(s) and identify the condition of the facility fire prevention program to commanders. Initiate development and annual review of pre-incident plans/pre-fire plans for facilities having a significant fire or loss-of-life potential, hazardous operations, all assigned aircraft, and any transient aircraft IAW applicable directives, instructions, regulations, standards and guidance.
18.1.2.4.2. FIRE PROTECTION DESIGN REVIEWS: Review plans to ensure all required features are present and local emergency response elements are incorporated (for example, accessibility to facility, location of fire hydrants, etc.). Provide review comments to the Engineering activity for incorporation in projects.
18.1.2.4.3. HOT WORK AND WELDING PERMITS: Establish and maintain a welding inspection and permit program.
18-1-6
18.1.2.4.4. EXPLOSIVE SAFETY: Coordinate FES fire response exercises, and munitions area fire drills.
18.1.2.4.5. EDUCATION: Implement a fire safety education program and utilize educational programs during fire inspections and other personal contacts. Promote fire safety education objectives to equip personnel with the information needed to prevent fires, protect themselves and intervene early when fire occurs. Ensure educational processes are in place to inform and motivate installation personnel concerning fire prevention responsibilities on a quarterly basis.
Conduct an expanded fire safety education program during National Fire Prevention Week.
18.1.2.5. FIRE EMERGENCY SERVICES (FES) OPERATIONS: Respond with appropriate number of qualified personnel and appropriate equipment to all fires, fire alarms, aircraft incidents, automobile accidents, hazardous material incidents, rescues, and miscellaneous fires/emergency situations. Develop pre-incident plans/pre-fire plans and review annually to facilitate early intervention at fire events. Record all facility pre-fire plans on an AF Form 1028, Facility Pre-Fire Plan, or government approved computer generated equivalent form. Record all Aircraft pre-fire plans on AFTO Form 88, Aircraft Pre-Fire Plan, or government computer generated equivalent. Conduct and participate in ad hoc meetings, teleconferences, Defense Connect Online (DCO) meetings, and information exchange with base and higher headquarters staff. Do not respond off the installation without approval from the Installation Commander or designated representative. Submit Fire Incident Response data to NFIRS and perform fire response reporting notification procedures IAW higher headquarters directives.
18.1.2.5.1. AIRCRAFT RESCUE AND FIRE FIGHTING (ARFF): Respond to and mitigate aircraft emergencies and hazardous situations involving aircraft. Respond with appropriate number of qualified personnel and appropriate equipment to all aircraft in-flight and ground emergencies to include on base and off base aircraft incidents involving government and government chartered aircraft, IAW with all applicable DoD, AF, and higher headquarters standards/instructions. Assume Incident Command (IC), secure the scene, establish emergency egress route, render medical aid, provide fire suppression and perform aircrew rescue when possible IAW DOD, AF, OSHA and NFPA firefighting guidance. If munitions are involved, the IC shall notify the Emergency Operations Center or Crisis Action Team, and perform safe-distance operations by command post, fire protection dispatch or other Vance AFB governing body. Ensure responses meet the time and distance requirements IAW higher headquarters directives and comply with DOD, AF, OSHA and NFPA firefighting guidance.
18.1.2.5.2. STRUCTURAL AND OTHER FIRE INCIDENTS: Respond to and mitigate structural fires/alarms, rescue situations and other emergency incidents. Respond with appropriate number of qualified personnel and appropriate equipment to all fire alarms, fire emergencies, automobile accidents and rescue situations IAW with all applicable DoD, AF, and higher headquarters standards/instructions. Perform Incident Command (IC), rescue operations, fire attack, ventilation, confinement, control, suppression, overhaul, and salvage IAW DOD, AF, OSHA and NFPA firefighting guidance. If munitions are involved, the IC shall notify the Emergency Operations Center or Crisis Action Team immediately and perform safe-distance operations. Ensure responses meet the time and distance requirements IAW higher headquarters directives and comply with OSHA and NFPA firefighting guidance.
18-1-7
18.1.2.5.3. HAZARDOUS MATERIAL (HazMat) AND CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR AND HIGH YIELD EXPLOSIVES (CBRNE) RESPONSE:
Respond with appropriate number of qualified personnel and appropriate equipment to HazMat and CBRNE incidents. Respond to releases and potential releases as part of the initial response to the incident. Perform incident command, control the scene, communications, accountability, contain the spill/release, fire suppression, rescue and extrication, emergency decontamination, secure the scene and preserve evidence. Perform limited atmospheric monitoring, detection, mass personnel decontamination, and operations in Immediately Dangerous to Life and Health (IDLH) locations. Ensure responses comply with DOD, AF, OSHA and NFPA guidance.
18.1.2.5.4. EMERGENCY MEDICAL SERVICES (EMS): Provide emergency medical response IAW applicable directives, instructions, regulations, standards, and AF EMS protocols which guide emergency response agencies. Fire Emergency Services will act as initial EMS responder and provide patient care at the Emergency Medical Responder (EMR) level. FES role in EMS shall be limited to non-transport Basic Life Support (BLS) at the Emergency Medical Responder (EMR) level of care from fire department apparatus. Firefighters shall not be used to staff ambulances or regularly provide assistance in transporting patients. The EMS program remains the responsibility of the installation medical group commander. The installation senior medical officer will provide the Service Provider with: EMS protocols; EMS program management oversight; and expendable supplies and durable equipment as specifically identified in the supply list approved by AF/SG3 and AF/A7C. Guidance for issuing supplies and equipment will be accomplished IAW AFI 41-209, paragraph 3.23, Medical Logistics Support. DHP funds shall not be used to purchase supplies and equipment items that are normally contained on FES response vehicles (i.e. backboards, extrication equipment, etc.). Comply with installation medical group EMS requirements and guidance. Provide emergency medical treatment under the medical direction of the Medical Group Commander or his/her designee. AF EMS protocols shall be used unless the appropriate Medical Group Command authorizes deviations in writing. All FES operations section personnel shall be trained and certified to the Department of Transportation (DOT) Emergency Medical Responder (EMR) level and shall be certified and registered as EMR by the State of Oklahoma IAW the current edition of the Emergency Response Systems Development Act, and Title 310 of the Oklahoma Administrative Code, Oklahoma State Department of Health Statutes and Regulations, Chapter 641, Emergency Medical Services.
Ensure responses meet time and distance requirements IAW higher headquarters directives and comply with DOD, AF, OSHA, NFPA and State guidance.
18.1.2.5.5. CONTINGENCY EXERCISES AND OPERATIONS: Participate in all exercises and operations. Respond to findings generated from exercises and operations. Provide timely, current emergency incident information to the Emergency Operation Center (EOC).
18.1.2.5.6. EQUIPMENT: Maintain equipment to ensure a constant state of readiness. Establish program requirements and implementation procedures to ensure all equipment is inspected, tested and maintained as required by DOD, AF, HHQ, OSHA, and NFPA requirements, and manufacturer’s recommendations. Document all inspections, testing, and maintenance in ACES- FD and government designated replacement system. Establish and maintain a respiratory
18-1-8 protection program for self-contained breathing apparatus (SCBA) IAW DOD, AF, and NFPA and OSHA requirements.
18.1.2.5.7. VEHICLES: All vehicles shall be inspected daily and maintained in a response ready posture. Validate that all vehicles and equipment are maintained in a safe and serviceable condition IAW applicable directives, instructions, regulations, standards National Fire Codes, manufacturers recommended instructions and military technical orders. Conduct and document required periodic (for example daily, weekly, monthly, and annual) inspections and tests. Record all fire pump testing, maintenance, and annual certifications on AF Form 1078, Fire Truck and Equipment Test, and Inspection Record, or government approved automated product.
Government provides fuel for government vehicles. Government provided vehicles may be used for official services associated with this contract and may not be used for other unauthorized purposes IAW official vehicle use policies.
18.1.2.6. KEGELMAN AAF DELEGATED AIRFIELD MANAGEMENT DUTIES (Separate CLIN): Perform Daily Airfield Check on Kegelman AAF active landing surface and aircraft movement areas prior to start of FES required duty day and marshaling aircraft as needed, as delegated to Fire Emergency Services in the Associate Contractor Agreement. Additionally, FES personnel will perform Runway Condition surveys and Emergency Wildlife Hazard Response as requested to aid in safe flight operations. FES personnel performing delegated Airfield Operations (AO) duties will be trained and certified by AO personnel and AO will retain liability for airfield operations.
18-2-1
SECTION 18-2
18.2. SERVICE SUMMARY
Performance Objectives PWS
Reference Performance Threshold
1. Maintain fully qualified and trained personnel for positions assigned
18.1.2.1. Zero discrepancies
2. Ensure ACES FD programs are updated as required
18.1.2.1. No more than 3 discrepancies per
quarter.
3. Conduct self-inspection to support the areas outlined in the current Higher Headquarters/IG Inspection Guidance
18.1.2.1. 100% compliance with having a program
4. Implement firefighter safety program IAW applicable standards and guidelines
18.1.2.2., 18.1.2.3.2.
No more than one reportable safety incident per quarter
5. Provide Emergency Communication Center services
18.1.2.1., 18.1.2.2.7.
No more than one valid customer complaints or unsatisfactory observations per quarter
6. Provide Fire Emergency Services Training
18.1.2.3. No more than two valid customer
complaints or unsatisfactory observations per quarter
7. Implement an effective Base Fire Prevention Program
18.1.2.4. No more than two valid customer
complaints or unsatisfactory observations per quarter
8. Implement and maintain a fire safety education program to educate personnel on fire prevention practices
18.1.2.4.5. No more than two valid customer
complaints or unsatisfactory observations per quarter
9. Respond to and mitigate aircraft emergencies and hazardous situations involving aircraft
18.1.2.5.1. Zero valid customer complaints or
unsatisfactory observations Inspections
10. Respond to and mitigate structural fires/alarms, rescue situations and other emergency incidents
18.1.2.5.2. Zero valid customer complaints or
unsatisfactory observations
11. Respond to and mitigate HazMat/CBRNE emergencies
18.1.2.5.3. Zero valid customer complaints or
unsatisfactory observations
12. Provide EMT-B certified and licensed personnel as required
18.1.2.5.4. Zero valid customer complaints or
unsatisfactory observations
13. Respond to and provide support to mitigate Emergency Medical Services emergencies
18.1.2.5.4. Zero valid customer complaints or
unsatisfactory observations
14. Respond to and mitigate emergencies involving miscellaneous fires
18.1.2.5. Zero valid customer complaints or
unsatisfactory observations
18-2-2
Performance Objectives PWS Reference
Performance Threshold
15. Implement and maintain equipment inspection and maintenance program
18.1.2.5.6. No more than one unsatisfactory
observation per quarter
16. Maintain equipment in a constant state of readiness
18.1.2.5.6. No more than one deviation per
quarter
17. Ensure all vehicles and equipment are maintained in a safe and serviceable condition
18.1.2.5.7. Zero unsatisfactory observations
18. Ensure all required vehicle and equipment periodic inspections and test are conducted and documented
18.1.2.5.7. No more than one unsatisfactory
observation per quarter
19. Respond to all suspense’s from base agencies and higher headquarters
18.1.2.1. No more than 1 late suspense per
month without prior approval from the Government
18-3-1
SECTION 18-3
18.3.1. GENERAL INFORMATION
Refer to Section 11-3 for General Information
18A-1
APPENDIX 18-A
18A.1. PUBLICATIONS
Refer to Section 11-A for a list of publications
18B-1
APPENDIX 18-B
18B.1. WORKLOAD ESTIMATES
Refer to Section 11-B for Workload Estimates
18C-1
APPENDIX 18-C
18C.1 MAPS AND WORK AREA LAYOUT
Refer to Appendix 11-C for Maps and Work Area Layouts
18D-1
APPENDIX 18-D
18D.1. REQUIRED REPORTS
Report Title Description/Form Submit To: Date Due Directive
1. National Fire Incident Reporting System
(NFIRS)
Fire Incident Report
Naval Safety Center, Norfolk, Va.
Daily & as Required
AFI 32-2001
2. Fire Department Emergency Response Message Notification
Fire Incident Report
Higher Headquarters
As Required
AFI 32-2001
3. Halon Report ACES-FD print-out
Higher Headquarters
Semi-annual
Higher Headquarters
4. Material Inspection and Receiving Report
DD Form 250 Departmental Use As Required
Government Directed
5. Serviceable Tag - Material
DD Form 1574 Departmental Use As Required
Government Directed
6. Unserviceable (Condemned) Tag – Material
DD Form 1577 Departmental Use As Required
Government Directed
7. Unserviceable (Reparable) Tag - Material
DD Form 1577-2 Departmental Use As Required
Government Directed
8. USAF Welding, Cutting, and Brazing Permit
AF Form 592 Departmental Use As Required
Government Directed
9. Equipment Action Request
AF Form 601 Departmental Use As Required
Government Directed
10. Water Flow Test Record
AF Form 1027 Departmental Use As Required
Government Directed
11. USAF Ground Fuel Identaplate
AF Form 1295 Departmental Use As Required
Government Directed
12. Facility Fire Prevention and Protection Record
AF Form 218 Departmental Use As Required
AFI 32-2001
13. Personal Clothing and Equipment Record
AF Form 538 Departmental Use As Required
AFI 32-2001
14. Facility Pre-Fire Plan AF Form 1028 Departmental Use As Required
AFI 32-2001
15. Inspection Maintenance Record
AF Form 1071 Departmental Use As Required
AFI 32-2001
16. Fire Truck and Equipment Test and Inspection Record
AF Form 1078 Departmental Use As Required
AFI 32-2001
18D-2
Report Title Description/Form Submit To: Date Due Directive
17. Fire Prevention Visit Report
AF Form 1487 Departmental Use As Required
AFI 32-2001
18. Operator’s Inspection Guide and Trouble Report
AF Form 1800, Departmental Use As Required
AFI 32-2001
19. SAVE Report Electronic Higher Headquarters
As Required
Government Directed
20. Fire Emergency Services Assessment Program (FESAP)
Electronic Higher Headquarters
As Required
AFI 90-201
and AFI 32-
21. Emergency Response Capability (ERC) Tracker
Electronic Higher Headquarters
As Required
Government Directed
22. Fire Emergency Response Data for Privatized Housing
Electronic Government Housing Manager
Monthly Government Directed
23. Standard of Response Coverage (SORC)
Electronic Higher Headquarters via
71 FTW/CC
Annual AFI 32-2001
24. FES Operational Risk Management Plan
Electronic Higher Headquarters via
71 FTW/CC
Annual AFI 32-2001
25. Strategic Plan Electronic Higher Headquarters via
71 FTW/CC
Annual AFI 32-2001
18E-1
APPENDIX 18-E
18E.1. COLLATERAL TASKS - (DUTIES)
Refer to PWS Section 2 Appendix E
18F-1
APPENDIX 18-F
18F.1. GOVERNMENT-FURNISHED PROPERTY AND SERVICES – SUPPLIES,
MATERIALS, AND LEASED EQUIPMENT
See GFE Appendix Attachment
FIRES EMERGENCY SERVICES
18FA-1
APPENDIX 18-FA
18FA.1. GOVERNMENT-FURNISHED PROPERTY -FACILITIES
Refer to Appendix 11-FA
18FB-1
APPENDIX 18-FB
18FB.1. GOVERNMENT FURNISHED PROPERTY-EAID
18FC-1
APPENDIX 18-FC
18FC.1. GOVERNMENT FURNISHED PROPERTY-NON-EAID
18-FD-1
APPENDIX 18-FD
1. GOVERNMENT FURNISHED PROPERTY-COMMON HAND TOOLS AND SPECIAL
TOOLS
DESCRIPTION QTY LOCATION
Portable Tool Box 3 Fire Department 32 pc Westward Wrench Set 1 SCBA Room - Brown Tool Box 32 pc Proto Socket Set 3/8 in Drive 1 SCBA Room - Brown Tool Box 8 pc Nicholson File Set 1 SCBA Room - Brown Tool Box 7 pc Proto Punch Set 1 SCBA Room - Brown Tool Box 13 pc Allen Hex Key Set 1 SCBA Room - Brown Tool Box 27 pc Proto Black Hawk 1/4 in Drive 1 SCBA Room - Brown Tool Box 3/8 " Drive Speed Handle K&S 1 SCBA Room - Brown Tool Box Diamond Brand #SL58-1P Wire Pliers 1 SCBA Room - Brown Tool Box Klien Tools D213-9ST Wire Pliers 1 SCBA Room - Brown Tool Box Rico 10 inch Pipe ·wrench 2 SCBA Room - Brown Tool Box Flat Tip Screwdriver 13 SCBA Room - Brown Tool Box Phillips Tip screw driver 3 SCBA Room - Brown Tool Box 13/16” Proto Wrench 1 SCBA Room - Brown Tool Box 1” KAL Open & Box Wrench 1 SCBA Room - Brown Tool Box 7/8" KAL Open & Box Wrench 1 SCBA Room - Brown Tool Box 15/16”KAL Open & Box Wrench 1 SCBA Room - Brown Tool Box 13/16” KAL Open & Box Wrench 1 SCBA Room - Brown Tool Box 3/4" KAL Open & Box Wrench 1 SCBA Room - Brown Tool Box Grizzly 12ft Tape measure 1 SCBA Room - Brown Tool Box Air Nozzel CEJN #207 1 SCBA Room - Brown Tool Box
11/16” Open End Wrench 1 SCBA Room - Brown Tool Box Battery Terminal Cleaner 1 SCBA Room - Brown Tool Box 12” Cresent Wrench 1 SCBA Room - Brown Tool Box 8” Cresent Wrench 1 SCBA Room - Brown Tool Box Multi-Wrench 1 SCBA Room - Brown Tool Box Dremel Model 290 Engraver 1 SCBA Room - Brown Tool Box 3/4" Cole Chisel 1 SCBA Room - Brown Tool Box Barco Claw Hammer Wooden Handle 1 SCBA Room - Brown Tool Box Claw Hammer Metal Handle 1 SCBA Room - Brown Tool Box Stanley 24 oz Ball Pen Hammer 1 SCBA Room - Brown Tool Box Nuple Flex FS-4 Power Drive 1 SCBA Room - Brown Tool Box
Anchor #388 Wire Brush 1 SCBA Room - Brown Tool Box
Scott Wrench 1 SCBA Room - Brown Tool Box
18-FD-2
Snap-on 15/8" Impact Socket 1 SCBA Room - Red Tool Box Snap-on 1/2 x 3/4 Drive Adaptor 1 SCBA Room - Red Tool Box Snap-on 1/2 x 3/8 Drive Adaptor 1 SCBA Room - Red Tool Box #4 Erwine Step Bit 1 SCBA Room - Red Tool Box Cylinder Valve Lock Wrench 1 SCBA Room - Red Tool Box Stanley Utility Knife 1 SCBA Room - Red Tool Box MSA 1st Stage Reg. Safety Clip 1 SCBA Room - Red Tool Box Snap-on Slip Joint Pliers, Water Pump 1 SCBA Room - Red Tool Box Snap-on Needle Nose Pliers 1 SCBA Room - Red Tool Box Snap-on 5 pc Snap Ring Tool 1 SCBA Room - Red Tool Box MSA Tool Kit 1 SCBA Room - Red Tool Box Cresent Flat Blade Screw Driver 1 SCBA Room - Red Tool Box Snap-on 3/16" Nut Driver 1 SCBA Room - Red Tool Box Snap-on 3/8 Drive Torque Wrench ft/pds
1 SCBA Room - Red Tool Box
Snap-on 3/8 Drive Torque Wrench inch/pds
1 SCBA Room - Red Tool Box
Audiolarm Piston Tools 2 SCBA Room - Red Tool Box Snap-on 11/16 Combination Wrench
1 SCBA Room - Red Tool Box
Snap-on 13/16 Combination Wrench 1 SCBA Room - Red Tool Box Snap-on 7/8 Combination Wrench 1 SCBA Room - Red Tool Box Snap-on 5/8 Combination Wrench 1 SCBA Room - Red Tool Box Snap-on 7/16 Combination Wrench 1 SCBA Room - Red Tool Box Snap-on 7/8 Crow Foot Wrench 1 SCBA Room - Red Tool Box Snap,on 13/16 Crow Foot Wrench 1 SCBA Room - Red Tool Box Snap-on 3/4 Crow Foot Wrench 1 SCBA Room - Red Tool Box Snap-on 11/16 Crow Foot Wrench 1 SCBA Room - Red Tool Box Snap-on 5/8 Crow Foot Wrench 1 SCBA Room - Red Tool Box Snap-on 7/8 Crow Foot Wrench 1 SCBA Room - Red Tool Box Snap-on 1” Deep Socket 1 SCBA Room - Red Tool Box Snap-on 7/8 Deep Socket 1 SCBA Room - Red Tool Box Snap-on 3/4" Deep Socket 1 SCBA Room - Red Tool Box Snap-on 11/16” Deep Socket 1 SCBA Room - Red Tool Box Snap-on 9/16” Deep Socket 1 SCBA Room - Red Tool Box Snap-on 7/16" Deep Socket 2 SCBA Room - Red Tool Box K&S 1/2” Deep Socket 1 SCBA Room - Red Tool Box Snap-on 1./4 “ Allen Wrench Socket 1 SCBA Room - Red Tool Box
18-FD-3
Snap-on 13/16” Allen Wrench Socket 1 SCBA Room - Red Tool Box Snap-on1/8” Allen Wrench Socket 1 SCBA Room - Red Tool Box Snap-on #2 Phillips Socket 1 SCBA Room - Red Tool Box Ear Protectors 2 SCBA Room - Red Tool Box 2nd Stage Adjustment Tools 3 SCBA Room - Red Tool Box 3/8" Drive Brake-over Handle 1 SCBA Room - Red Tool Box Wrench Set(1-Stanley, 2-Easco) 3 Extinguisher Mx Tool Chest Ball Pen Hammer 1 Extinguisher Mx Tool Chest Wire Brush 2 Extinguisher Mx Tool Chest 8" Pipe Wrench Rico 1 Extinguisher Mx Tool Chest 10" Pipe Wrench Rico 1 Extinguisher Mx Tool Chest 10" Pipe Wrench Ridgid 2 Extinguisher Mx Tool Chest 14" Pipe Wrench Ridgid 3 Extinguisher Mx Tool Chest 24" Pipe Wrench Rico 1 Extinguisher Mx Tool Chest Grease Guns 2 Extinguisher Mx Tool Chest Cresent Wrench(1-Top, 3-Williams) 4 Extinguisher Mx Tool Chest Pliers 6 Extinguisher Mx Tool Chest Screw Driver, flat 6 Extinguisher Mx Tool Chest Screw Driver, Phillips 3 Extinguisher Mx Tool Chest 3/8" Stanley Socket Set, standard 1 Extinguisher Mx Tool Chest Proto Punch Set 1 Extinguisher Mx Tool Chest Claw Hammer Stanley 1 Assistant Fire Chief’s Office 12" Cresent 1 Assistant Fire Chief’s Office Vice Grips Pliers 1 Assistant Fire Chief’s Office Slip-Joint Pliers Cresent 1 Assistant Fire Chief’s Office 3/8 x 7/16 Wrench 1 Assistant Fire Chief’s Office 13/32 x 5/16 Wrench 1 Assistant Fire Chief’s Office Screw Driver Kit VACO 1 Assistant Fire Chief’s Office Flat Screw Drivers 6 Assistant Fire Chief’s Office Phillips Screw Drivers 4 Assistant Fire Chief’s Office Proto Wrench Set, Standard, Box End 5/16” through 1-1/8”
1 Assistant Fire Chief’s Office
18-FE-1
APPENDIX 18-FE
18FE.1. GOVERNMENT FURNISHED PROPERTY AND SERVICES – ITAM & AIM
18FE.1.1. ITAM Inventory
Bldg Room Part Number Serial Number Model
Number Model Description Init
Install Date
140 AC 578800303S USB1029189 C4111A
PRINTER,
LASERJET 5000N 18-Dec-98
140 AC 375-2438 MX07V6YP7287598H0P4I E2209W
DELL E2209W 22IN
WIDESCREEN
MONITOR 22-Sep-09
140 AC 375-2438
MX07V6YP7287598H0PM
I E2209W
DELL E2209W 22IN
WIDESCREEN
MONITOR 22-Sep-09
140 AC
SK878UC-
ABA MXL0410RTJ 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 AC
SK878UC-
ABA MXL0410RTW 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 Admin 375-2438
MX07V6YP7287598H0LL
I E2209W
DELL E2209W 22IN
WIDESCREEN
MONITOR 22-Sep-09
140 Admin
SK878UC-
ABA MXL0410RS7 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 FACC 0E251 9HGY131 GX260T
DELL OPTIPLEX
GX260T P4 2.40GHZ 14-Jul-03
140 FACC 375-2366
MX0K474F7426297U1AH
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 FACC 375-2366 MX0K474F7426297U1AJS E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 FACC 375-2438
MX07V6YP7287598H0PU
I E2209W
DELL E2209W 22IN
WIDESCREEN
MONITOR 22-Sep-09
140 FACC MJ17ASSB MJ17HCHX516786 710N
SAMSUNG 17IN
LCD ANALOG
MONITOR 19-Jul-04
140 FACC
PHASER-
AF3600DN
G MHB890994 3600DNG
XEROX PHASER
AF3600DNG LASER
PRINTER 8-Nov-10
18-FE-2
Bldg Room Part Number Serial Number Model Number Model Description Init Install
Date
140 FACC
PHASER-
AF3600DN
G MHB899023 3600DNG
XEROX PHASER
AF3600DNG LASER
PRINTER 1-Nov-10
140 FACC
SK878UC-
ABA MXL0410RS5 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 FACC
SK878UC-
ABA MXL0410RSM 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 FACC 57880032JF SG0AU1219W C2690A
HP INKJET 2200CXI
PRINTER 21-Jun-01
140 FC 375-2438 MX07V6YP7287598H0L9I E2209W
DELL E2209W 22IN
WIDESCREEN
MONITOR 22-Sep-09
140 FC
SK878UC-
ABA MXL0410RSG 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 INSP 224-3478 2LW7SG1 2330DN
DELL 2330DN TAA
MONOCHROME
LASER PRINTER
20-Aug-
140 INSP
2443BWT-
TAA MY24HCGS710004N 2443BWT
SAMSUNG 24IN
2443B
WIDESCREEN LCD
FLAT PANEL
20-Aug-
140 INSP
2443BWT-
TAA MY24HCGS710009J 2443BWT
SAMSUNG 24IN
2443B
WIDESCREEN LCD
FLAT PANEL
20-Aug-
140 INSP
IX270AET
C ZZGEG7271ZZ4064 IX270
ITRONIX GOBOOK
XR-1 18-Oct-07
140 INSP
IX270AET
C ZZGEG7277ZZ4403 IX270
ITRONIX GOBOOK
XR-1 18-Oct-07
140 INSP
SK878UC-
ABA MXL0410RTG 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 INSP
SK878UC-
ABA MXL0410RTH 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 OFFC
CF-
19CHGXB
M 7FKYA52862R
CF-
19CHGX
BM
PANASONIC
TOUGHBOOK CF-19
LAPTOP 16-Jul-07
140 SCBA 224-3478 26W7SG1 2330DN
DELL 2330DN TAA
MONOCHROME
LASER PRINTER
20-Aug-
18-FE-3
Bldg Room Part Number Serial Number Model Number Model Description Init Install
Date
140 SCBA 375-2366
MX0K474F7426297U1A9
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 SCBA 375-2366
MX0K474F7426297U1CK
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 SCBA
SK878UC-
ABA MXL0410RSH 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 SCBA 57880032JG SG0A02626R C7675A
HP SCAN JET
6350CXI 22-Jun-01
140 SCBA
GR463UC-
ABA MXL7480DPL DC5750M
HP DC5750M
EXPANDABLE
MINI-TOWER
2.4GHZ 7-Dec-07
140 Suply 375-2366
MX0K474F7426297U1AM
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 Suply 7373C65 MJCRFND M58
LENOVO
THINKCENTRE M58 9-Apr-12
140 TRAIN 1908FP
MX0DY5264663478T1DM
U 1908FP
DELL ANALOG
AND DIGITAL
1908FP 19IN DUAL
MONITOR 18-Sep-07
140 TRAIN 47VHW
MX0DY526742627AH47C
U 1908FP
DELL 1908FP 19IN
FLAT MONITOR 31-Oct-07
140 TRAIN
SK878UC-
ABA MXL0410N8N 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER 9-Nov-10
140 TRNG 223-9338 2V08HK1 E6400
DELL LATITUDE
E6400 LAPTOP 20-Apr-10
140 TRNG 375-2366
MX0K474F7426297U1C1
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 TRNG 375-2366 MX0K474F7426297U1CJS E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 TRNG 375-2438 MX07V6YP7287598H0L3I E2209W
DELL E2209W 22IN
WIDESCREEN
MONITOR 22-Sep-09
140 TRNG
SK878UC-
ABA MXL0410RT2 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
18-FE-4
Bldg Room Part Number Serial Number Model Number Model Description Init Install
Date
140 TRNG
SK878UC-
ABA MXL0410RTF 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG
SK878UC-
ABA MXL0410RV2 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG 375-2366
MX0K474F7426297U1AN
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 TRNG 375-2366
MX0K474F7426297U1C3
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 TRNG 375-2366
MX0K474F7426297U1C4
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 TRNG 375-2366
MX0K474F7426297U1CF
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
140 TRNG
CF-
19CHGXB
M 7FKYA52694R
CF-
19CHGX
BM
PANASONIC
TOUGHBOOK CF-19
LAPTOP 16-Jul-07
140 TRNG
SK878UC-
ABA MXL0410N9P 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG
SK878UC-
ABA MXL0410RSF 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG
SK878UC-
ABA MXL0410RV5 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG
SK878UC-
ABA MXL0410RV6 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG
SK878UC-
ABA MXL0410RV8 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER
10-Nov-
140 TRNG
CF-
19CHGXB
M 7FKYA52815R
CF-
19CHGX
BM
PANASONIC
TOUGHBOOK CF-19
LAPTOP 16-Jul-07
413 N/A 0CC388
CN0CC3887161868GAE4
H 1907FPV
DELL 1907FPV 19IN
MONITOR
28-Nov-
413 Office
SK878UC-
ABA MXL0410JB3 6005PRO
HP 6005 PRO
EXPANDABLE
MINI-TOWER 2-Nov-10
18-FE-5
Bldg Room Part Number Serial Number Model Number Model Description Init Install
Date
413 Office 1708FPT
CN-0KU789-71618-76P-
BA4T 1708FPT
DELL ULTRA
SHARP 17 INCH
LCD MONITOR 23-Jun-14
413 NULL 7373C65 MJCRFMZ M58
LENOVO
THINKCENTRE M58 9-Apr-12
413 NULL L1942P-BS 808NDWEDK481
L1942P-
BS
FLATRON L1942P-
BS 19IN LCD
MONITOR 4-Sep-09
500 24 MJ17ASSB MJ17H9NX417389 710N
SAMSUNG 17IN
LCD ANALOG
MONITOR 19-Jul-04
500 24
POWERED
GE830 6RWY191
POWERE
DGE 830
DELL POWEREDGE
830 22-Dec-05
KAA
F
Fire Station 375-2366
MX0K474F7426297U1C2
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
KAA
F
Fire Station 375-2366
MX0K474F7426297U1CE
S E1909W
DELL E1909W 19IN
WIDESCREEN
MONITOR
18-Aug-
KAA
F Fire
Station 7373C65 MJCRGCK M58
LENOVO
THINKCENTRE M58 9-Apr-12
KAA
F Fire
Station 7373C65 MJCRGCN M58
LENOVO
THINKCENTRE M58 9-Apr-12
KAA
F Fire
Station 976105 CN6B7GY1KD Q8134A
HP DJ F380 ALL-IN-
ONE 2-Mar-07
KAA
F
Fire Station
SAM-SCX-
5635FN-
XAR Z2UGB1BS700303
SCX-
5635FN-
XAR
SAMSUNG
MONOCHROME
MULTIFUNCTION
LASER PRINTER 28-Sep-09
18FE.1.2. AIM Inventory
Description Model Part Number Serial Number Location
CHARGER RF-5853-
CH001
RF-5853 UCC12541420 Bldg 140
ADVANCED TONE
DESKSET
MC 2000
TONE L3216A
124CFG0546 Bldg 140
RADIO MOBILE ASTRO D04KKF9PW5A 412CDC1122 Bldg 140 RADIO MOBILE ASTRO D04KKF9PW5A 412CDC1126 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEC9PW5 320CDU7944 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEC9PW5AN 320CLZ0640 Bldg 140
18-FE-6
Description Model Part Number Serial Number Location BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0171 Bldg 140 RADIO MOBILE ASTRO D04KKF9PW5A 412CDC1148 Bldg 140 RADIO MOBILE ASTRO D04KKF9PW5A 412CDC1165 Bldg 140
RADIO HANDHELD -
HARRIS
AN/PRC-
152(V)1(C)
ON689740-7 109018 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEH9PW7 320CDU6437 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEH9PW7 320CDU6436 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEH9PW7 320CDU6438 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEC9PW5 320CDU7942 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0641 Bldg 140
RADIO MOBILE ASTRO D04KKF9PW5A 412CDC1133 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEH9PW7 320CDU6439 Bldg 140
BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0150 Bldg 140
RADIO HANDHELD
- AES
XTS 3000 H09KDC9PW5 620CCW1893 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEC9PW5 320CDU7943 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEC9PW5 320CDU7941 Bldg 140
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CLZ0133 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0642 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0644 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0643 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0646 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEC9PW5 320CDU7945 Bldg 140
BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0156 Bldg 140
RADIO HANDHELD
- AES
XTS 3000 H09KDC9PW5 620CCW1892 Bldg 140
RADIO HANDHELD
- AES
XTS 3000 H09KDC9PW5 620CDG0497 Bldg 140
18-FE-7
Description Model Part Number Serial Number Location
RADIO HANDHELD
- AES
XTS 3000 H09KDC9PW5 620CCW1889 Bldg 140
BASE STATION ASTRO L04KKH9PW7A 374CDG0015 Bldg 140 BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDC1156 Bldg 140 BASE MOBILE ASTRO D04KKF9PW5A 412CDC1158 Bldg 140 BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0152 Bldg 140 BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0158 Bldg 140 BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0165 Bldg 140 BASE MOBILE ASTRO D04KKF9PW5A 412CDE0167 Bldg 140 BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0170 Bldg 140
RADIO HANDHELD
- AES
XTS 3000 H09KDC9PW5 620CCW1891 Bldg 140
RADIO HANDHELD
- AES
XTS 3000 H09KDC9PW5 620CCW1894 Bldg 140
RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0495 Bldg 140 RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0496 Bldg 140 RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0498 Bldg 140 RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0499 Bldg 140 RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0500 Bldg 140 RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0501 Bldg 140 RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0502 Bldg 140 RADIO HANDHELD ASTRO H09KDC9PW5 412CDC1131 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0647 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0648 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0649 Bldg 140
BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDE0153 Bldg 140 BASE MOBILE - AES ASTRO D04KKF9PW5A 412CDC1121 Bldg 140
RADIO HANDHELD-
AES/OTAR/P25
XTS 5000 H18KEH9PW7 320CDU6440 Bldg 140
RADIO HANDHELD
- AES / IS / P25
XTS 5000 H18KEC9PW5AN 320CLZ0645 Bldg 140
RADIO BASE -
AES/OTAR/P25
XTL5000
CONSOLETTE
L20KSS9PW1AN 276CMX0372 Bldg 150
TONE REMOTE MC 1000
TONE
L3213 124CMY0529 Bldg 413
ADVANCED TONE
DESKSET
MC 2000
TONE
L3216A 124CNA0057 Bldg 413
BASE STATION -
AES
ASTRO L04KKH9PW7A 374CDE0036 Bldg 413
RADIO MOBILE MCS2000 M01MX513W 623ABW0664 Bldg 500 RADIO MOBILE MCS2000 M01MX513W 623ABW0703 Bldg 500
18-FE-8
BASE STATION ASTRO L04KKH9PW7A 374CDE0035 Bldg 509 Description Model Part Number Serial Number Location
TONE REMOTE MC 1000
TONE
L3213 124CCY0191 Bldg 1037
TONE REMOTE MC 1000
TONE
L3213 124CCY0268 Bldg 1038
RADIO BASE -
AES/OTAR/P25
XTL5000
CONSOLETTE
L20KSS9PW1AN 276CMX0054 Bldg 413
BASE STATION ASTRO L04KKH9PW7A 374CDG0014 Kegelman FD
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CLZ0134 Kegelman FD
TONE REMOTE MC 1000 TONE L3213 124CCY0279 Kegelman FD
RADIO HANDHELD -
AES
XTS 3000 H09KDC9PW5 620CCW1890 Kegelman FD
RADIO HANDHELD XTS 3000 H09KDC9PW5 620CDG0503 Kegelman FD
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CLZ0129 Kegelman FD
RADIO HANDHELD
- HARRIS
AN/PRC-
152(V)1(C)
ON689740-7 109260 Kegelman FD
CHARGER - HARRIS RF-5853-
CH001
RF-5853 UCC12541415 Kegelman FD
TONE REMOTE MC 1000
TONE
L3213 124CCY0387 Kegelman FD North RSU
TONE REMOTE MC 1000
TONE
L3213 124CCY0308 Kegelman FD South RSU
TONE REMOTE MC 1000
TONE
L3213 124CCY0271 Kegelman FD Storage
TONE REMOTE MC 1000
TONE
L3213 124CCY0278 Kegelman FD Storage
BASE MOBILE ASTRO D04KKF9PW5A 412CDE0166 Kegelman FD
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CMX1131 Not Listed on AIM Inventory
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CMX1161 Not Listed on AIM Inventory
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CMX1164 Not Listed on AIM Inventory
RADIO MOB -
AES/OTAR/P25
XTL5000 M20KSS9PW1AN 585CMX1167 Not Listed on AIM…
This is the start of the file's text. The full file is on GovTribe.