EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_C_-_Startionary_Armored_Targets_(SATs).pdf

PDF 71 KB Posted

Attached to
Jack Mountain Multi-Use (JMMU) Range Upgrades, Rep Federal contract opportunity
Solicitation number
140D0426R0084
Issued by
Department of the Interior Departmental Offices Interior Business Center

About this file

This document is an exhibit providing target designation reference information for Stationary Armored Targets (SATs) at the JMMU (Joint Multinational Training Center or similar military facility). The exhibit contains a comprehensive inventory and technical specifications for 59 SATs organized by current designation, historical designation, location relative to Line of Advance (LOA), and specific characteristics.

The SAT inventory includes 27 targets positioned behind the LOA and 32 targets positioned forward of the LOA, with each target receiving a fiber count of 6 for a total of 354 fiber strands. Key specifications tracked for each SAT include power center connections (PJ1A through PJ9A), drainage ditch requirements, elevation status (No, Semi, or Depression), and special features. The document identifies three SAT/SIT (Stationary/Semi-mobile Integrated Target) combination clusters at pits 420/C62, 426/C64, and 440/C66, each containing four SIT targets within the SAT pit and requiring 16 fiber count and 4 fibers fed from SITs. Additionally, the JMMU maintains 10 Heavy SATs (HSATs) designated for specific pits (458, 470, 472, 486, 490, 494, 496, 502, 512, and 518), which differ from regular SATs in configuration. Notable maintenance items include drainage ditch grading requirements for multiple targets and the replacement of a missing heavy SAT target at pit 458.

View the file

Other files for this federal contract opportunity

Other files attached to Jack Mountain Multi-Use (JMMU) Range Upgrades, Rep, newest first.
File Type Posted
Sol_140D0426R0084_Amd_0002.pdf PDF
SQA_Q_A_JMMU_Ft__Hood_0002.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part2_0001.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part1_0001.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part6_0001.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part5_0001.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part3_0001.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part7_0001.pdf PDF
Sol_140D0426R0084_Amd_0001.pdf PDF
EXHIBIT_F_-_CCMU_JMMU_2001_Part4_0001.pdf PDF
B03_WD_TX20260279.pdf PDF
EXHIBIT_B_-_JMMU_CLUSTER_LOCATIONS_FOR_MIT_LOCATIONS.pdf PDF
EXHIBIT_K_-_TXDOT_Concrete_Repair_Manual_crm.pdf PDF
EXHIBIT_S_-_Target_Protection_-_July_2017.pdf PDF
EXHIBIT_V_-_CCI-TII_Checklist_Instructions.pdf PDF
EXHIBIT_W_-_CCI-TII_Checklist.pdf PDF
EXHIBIT_X_-_Portable_HSAT_Specifications.pdf PDF
EXHIBIT_Y_-_Range_Limit_Marker_Design.pdf PDF
EXHIBIT_Z_-_JMMU_SACON_Trench_System_Repairs.pdf PDF
EXHIBIT_BB_-_Firing_Positions_Revision_6.pdf PDF
EXHIBIT_CC_-_EXISTING_CONDITIONS_PHOTOS.pdf PDF
EXHIBIT_E___Cluster_MIT_V-Shape_Formation.pdf PDF
B08_SOL_Fort_Hood_JMMU_Range_Upgrades_SOW.pdf PDF
EXHIBIT_H_-_SIT_Cluster_November_2018.pdf PDF
EXHIBIT_N_-_Mandatory_Shutdown_times.pdf PDF
EXHIBIT_O___Summary_Target_Electrical_and_Communications.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_B_-_Clusters_and_Moving_Infantry_Targets_(MITs).pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_D_-_Drainage_(ditches_culverts_and_sump_pumps).pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_E_-_Power_Centers.pdf PDF
EXHIBIT_U_-_Gate_Design.pdf PDF
EXHIBIT_AA___DMMU_MAT_System_locations_and_existing_conditions.pdf PDF
Sol_140D0426R0084.pdf PDF
EXHIBIT_A_-_FTHOOD-JMMU-AERIAL.pdf PDF
EXHIBIT_G_-_Moving_InfantryTarget_(MIT)_-_Aug2017.pdf PDF
EXHIBIT_J_-_Moving_Armor_Target_(MAT)_-_Aug2017.pdf PDF
EXHIBIT_L_-_JMMU_RANGE_SITE_SUMMARY_PCs_AND_CAMERA.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_A_-_Moving_Armored_Targets_(MATs).pdf PDF
EXHIBIT_T_-_Portable_Armored_Target_Protection.pdf PDF
EXHIBIT_FF_-_PKRA_FIRING_POSITION_ASBUILT_DRAWING.pdf PDF
EXHIBIT_GG_-_QTR_FIRING_POSITION_ASBUILT_DRAWING.pdf PDF
B08_SOL_140D0426R0084_JMMU_Range_Upgrades_Fort_Hood.pdf PDF
EXHIBIT_C_-_JMMU_MAT54_MAT56__MAT58___AT60_CROSS-SECTION.pdf PDF
EXHIBIT_D_-_Moving_Armor_Target_MAT_Locations.pdf PDF
EXHIBIT_I_-_Stationary_ArmorTarget_(SAT)_-_Aug2017.pdf PDF
EXHIBIT_M_-_Species_List_for_Range_Seed.pdf PDF
EXHIBIT_P_-_ELECTRICAL_AND_COMMUNICATIONS.pdf PDF
EXHIBIT_Q___TC25-8_Minimum_MAT_Specification_Requirements.pdf PDF
EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_F_-_Fiber_Optics.pdf PDF
EXHIBIT_DD_-_BGRC_FIRING_POSITION_ASBUILT_DRAWING.pdf PDF
EXHIBIT_EE_-_CCRB_FIRING_POSITION_ASBUILT_DRAWING.pdf PDF
Show all 50

Jack Mountain Multi-Use (JMMU) Range Upgrades, Rep has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT R - JMMU Target Designation Ref:

TAB C - Stationary Armored Targets (SATs)

SAT

CURRENT

DESIGNAT

ION

DESIGNATIO

N powered by power center NOTES

Front Wall Height?

Drainage Ditch Y/N?

Super Elevated? # SATs fiber count fiber fed from sits

412 JV-1 Behind LOA PJ1A Ditch No 1 6

414 JV-6 Behind LOA PJ1A No No 1 6

416 JV-2 Behind LOA PJ2A No Semi 1 6

418 JV-3 Behind LOA PJ2A No Yes 1 6

420/C62 JV-4 Behind LOA PJ1B combo SAT/SIT cluster C62. 4 SITS IN SAT PIT. Sump pump

Ditch & Sump Depression 1 6 4

422 JV-11 Behind LOA PJ3A No No 1 6

424 JV-12 Behind LOA PJ3A Access road washed out Ditch No 1 6

426/C64 JV-7 Behind LOA PJ2A combo SAT/SIT cluster C64. 4 SITS IN SAT PIT. Ditch No 1 6 4

428 JV-9 Behind LOA PJ2A Ditch No 1 6

430 JV-10 Behind LOA PJ2A No Yes 1 6

432 JV-8 Behind LOA PJ1B Ditch Depression 1 6

434 JV-18 Behind LOA PJ3A Ditch No 1 6

436 JV-14 Behind LOA PJ3A Ditch No 1 6 ECM-1

438 JV-19 Behind LOA PJ4A Ditch No 1 6

440/C66 JV-15 Behind LOA PJ4A combo SAT/SIT cluster C66. 4 SITS IN SAT PIT. No Yes 1 6 4

442 JV-22 Behind LOA PJ4A Ditch No 1 6

444 JV-20 Behind LOA PJ4A No Yes 1 6

446 JV-16 Behind LOA PJ2B No Yes 1 6

448 JV-17 Behind LOA PJ2B No Semi 1 6

450 JV-24 Behind LOA PJ5A Ditch No 1 6

452 JV-26 Behind LOA PJ3B Ditch No 1 6

454 JV-27 Behind LOA PJ3B Need drainage ditch graded Ditch No 1 6

456 JV-30 Behind LOA PJ5A Ditch No 1 6

458 JV-28 Behind LOA PJ3B Heavy SAT. Target Missing Need drainage ditch graded Ditch No 2 6

460 JV-21 Behind LOA PJ3B Need drainage ditch graded Ditch No 1 6

462 JV-29 Behind LOA PJ3B Ditch Depression 1 6

464 JV-33 Behind LOA PJ4B Feeds RLM Ditch Depression 1 6

466 JV-31 Forward of LOA PJ5A No No 1 6

468 JV-36 Forward of LOA PJ6A No Semi 1 6

470 JV-32 Forward of LOA PJ5A Heavy SAT Ditch No 2 6

472 JV-38 Forward of LOA PJ4B Heavy SAT No No 2 6

474 JV-34 Forward of LOA PJ6A No Semi 1 6

476 JV-35 Forward of LOA PJ6A has sump pump dam around target & sump pump Depression

1 6

478 JV-37 Forward of LOA PJ4B No Yes 1 6

480 JV-41 Forward of LOA PJ5B No Yes 1 6

482 JV-39 Forward of LOA PJ6A No No 1 6

484 JV-40 Forward of LOA PJ6A Ditch No 1 6

486 JV-42 Forward of LOA PJ5B Heavy SAT Ditch No 2 6

488 JV-47 Forward of LOA PJ7A No No 1 6

490 JV-49 Forward of LOA PJ5B Heavy SAT No No 2 6

492 JV-51 Forward of LOA PJ6B No Yes 1 6

494 JV-46 Forward of LOA PJ7A Heavy SAT No Semi 2 6

496 JV-48 Forward of LOA PJ7A Heavy SAT Ditch No 2 6

498 JV-44 Forward of LOA PJ8A No Semi 1 6

502 JV-45 Forward of LOA PJ8A Heavy SAT No Semi 2 6

504 JV-53 Forward of LOA PJ7A No Yes 1 6

506 JV-55 Forward of LOA PJ6B No Yes 1 6

508 JV-59 Forward of LOA PJ7B No Semi 1 6

510 JV-60 Forward of LOA PJ7B No Yes 1 6

512 JV-63 Forward of LOA PJ7B Heavy SAT No No 2 6

514 JV-70 Forward of LOA PJ7B No Yes 1 6

516 JV-54 Forward of LOA PJ9A No No 1 6

518 JV-57 Forward of LOA PJ9A Heavy SAT No No 2 6

520 JV-58 Forward of LOA PJ8B No Yes 1 6

522 JV-56 Forward of LOA PJ9A has mafia block No Yes 1 6

524 JV-61 Forward of LOA PJ8B No Yes 1 6

526 JV-62 Forward of LOA PJ8B No Yes 1 6

528 JV-67 Forward of LOA PJ8B No Yes 1 6

530 JV-68 Forward of LOA PJ8B No Yes 1 6

69 354 12 total of 59 SATs each target receives 6 fiber count for a total of 354 fiber count

(32 SATs) 192 Strands forward of LOA

27 of 59 behind LOA 32 of 59 forward of LOA

JMMU does have 10 HSAT's, The HSAT's are different than the regular SAT's. Pit is the same and the target pits that require a HSAT are

470 Heavy SAT’s pits are458, 470, 472, 486, 490, 494, 496, 502, 512, 518 486 SAT’s with SIT’s pits are 420, 426 and 440 494 420/C62 496 426/C64 502 440/C66

SIT/SAT COMBOs (C62, C64, C66)= 12 SIT targets @ 3 SATS (SAT420, SAT426, SAT440)

File details come from the government source that posted it. Updated .