EXHIBIT_R_-_JMMU_Target_designation_ref__TAB_B_-_Clusters_and_Moving_Infantry_Targets_(MITs).pdf
PDF 65 KB Posted
- Attached to
- Jack Mountain Multi-Use (JMMU) Range Upgrades, Rep Federal contract opportunity
- Solicitation number
- 140D0426R0084
About this file
This document is an exhibit providing target designation reference specifications for the JMMU (Joint Modernization Munitions Unit) program, specifically detailing clusters and moving infantry targets (MITs).
The exhibit presents a comprehensive table of 15 clusters containing 105 targets, with an additional 12 SIT targets at 3 SATs (SAT420, SAT426, SAT440) designated as SIT/SAT combos (C62, C64, C66), totaling 117 SITs. Each target is allocated 6 fiber count for a combined total of 630 fiber strands. Of these, 252 strands are positioned forward of the Line of Attack (LOA). Target specifications include designation identifiers, topography classifications (low, semi, or medium built-up), front wall heights (16-inches standard), ditch presence indicators, super elevation status, and power center assignments (designated as PJ2A through PJ5B and JP6A variants). Targets are categorized as either behind or forward of the LOA, with specific power center designations determining fiber feed configurations. This technical reference document serves to standardize target construction and resource allocation across the identified cluster array.
View the file
Other files for this federal contract opportunity
Show all 50
Jack Mountain Multi-Use (JMMU) Range Upgrades, Rep has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT R - JMMU Target Designation Ref:
TAB B - Clusters and Moving Infantry Targets (MITs) cluster CURRENT
DESIGNATION
designation
BUILD MIT
AT TGT# topography notes drawing
Front Wall Height? Ditch?
Super Elevated powered by power center fiber count fiber fed from
C12 JC-1
Behind LOA low 16-inches No No PJ2A 42 PJ2A C14 JC-2 1 Behind LOA low 16-inches No Semi PJ2A 42 PJ2A
C16 JC-5 1 Behind LOA semi 16-inches No Semi PJ2B 42 PJ2B C18 JC-8 1 Behind LOA semi 16-inches No Semi PJ2B 42 PJ2B C20 JC-4 1 Behind LOA semi 16-inches No Semi PJ1A 42 PJ1A
C22 JC-6 7 Behind LOA semi 16-inches No Semi PJ3A 42 PJ3A C24 JC-7 7 Behind LOA med built up 16-inches No Yes PJ4A 42 PJ4A C26 JC-9 no Forward of LOA low 16-inches No Semi JP6A 42 JP6A C28 JC-3 7 Forward of LOA low 16-inches No No JP6A 42 JP6A
C30 JC-10
Behind LOA low 16-inches Ditch No PJ5A 42 PJ5A
C32 JC-11
Behind LOA semi 16-inches No Semi PJ4B 42 PJ4B C34 JC-14 1 Forward of LOA semi 16-inches No Semi PJ5A 42 PJ5A
C36 JC-12 7 Forward of LOA low 16-inches Ditch No JP6A 42 JP6A C38 JC-13 no Forward of LOA semi 16-inches No Semi JP6A 42 JP6A
C40 JC-15
Forward of LOA LOW 16-inches Ditch No PJ5B 42 PJ5B C62 C64 C66 other Clusters at heavy SATs
15 clusters = 105 targets SIT/SAT COMBOs (C62, C64, C66)= 12 SIT targets @ 3 SATS (SAT420, SAT426, SAT440) TOTAL 117 SITs each target receives 6 fiber count for a total of 630 fiber count
(42 SITs) 252 strands forward of LOA
File details come from the government source that posted it. Updated .