This document is an installation and operation manual for an Energenics Tunnel Dryer Lint Filter model MLF-1004/1010/1015. It provides detailed instructions for the receiving, installation, start-up, operation, and maintenance of the lint filter. Key details include descriptions of the lint filter operation, important installation considerations, warnings/cautions, typical on-board and remote installation configurations, utility requirements, maintenance schedules, and procedures for cleaning the filter screen.
The related federal contract opportunity is a solicitation for Laundry Equipment Preventive Maintenance (PM) and Repair Services for the Gulf Coast Veterans Healthcare System in Biloxi, Mississippi. This is a 100% small business set-aside for various small business categories. The contract requires continuous, uninterrupted operation of the laundry facility in support of veteran patient care.
View the file
Other files
Show 40 more
Latest 50 of 57 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.energenics.com
1470 Don Street Naples, Florida 34104 Telephone: (239) 643-1711 Fax: (239) 643-6081 Customer Service: (800) 944-1711
Installation & Operation Manual For MILNOR MLF-1004/1010/1015 On-board or Remote mounted
Individual Lint Filters
Descriptions Page
Table of Contents 1
Description of Lint Filter Operation 2 Important Installation Considerations
Receiving and Installation 3
Warnings/Cautions 4 Start Up and Operation Instructions
Typical On-Board Installation 5
Typical Remote Installation 6
Utilities Installation 7
Sheet Metal Installation 8
Compressed Air Requirements 9
Fire Suppression Water System 10
Dryer/Filter Utility Requirements 11
Side View Connection Location 12
IMPORTANT WARNING/GATE VALVE MAINTENANCE 13
Optional 6” Vacuum with 150 Gallon Lint Storage 14
Motor Starter Wiring for Optional Vacuum 15
Maintenance Requirements 16
MAINTENANCE REQUIREMENTS
The frequency of your maintenance requirements depends upon the number of hours of operation and upon variances in your product output. For a single-shift operation, without special problems, the frequency recommended below should suffice. You should set your own schedule based on your experience.
1. WEEKLY
Visually inspect the filter inside and outside, its controls and their operation.
At time of such inspection, note and correct any discrepancies from normal operation.
2. MONTHLY
Check the static pressure. Use a magnehelic gauge, manometer, or U-tube to measure and record the resistance. This will show the pattern of operation of your system. If pressure exceeds 1 inch W.C., insure the rotor is correctly turning and cleaning the screen.
Watch the air pressure gauge on the filter. Record the drop in pressure during the blow down cycle. A normal pressure is from 100psi at the start to 60psi after six seconds. The minimum pressure is 60psi. Any less will not reliably clean the screen. If the pressure were to fall from 100psi to 40psi, the air supply is inadequate or obstructed.
3. QUARTERLY
Test the Fenwall fire sensor accessed through the inspection door. Heat the Fenwell fire sensor with a heat lamp or other convenient source. When the audible/visual indicators actuate as well as the water solenoid remove heat source and allow Fenwell fire sensor to cool. The fire suppression system will reset after 60 seconds.
FILTER SCREEN MAINTENANCE
Chemicals present in the laundry uniforms, shop towels or other linen may eventually clog the filter screen. When this occurs, try the following:
1. Spray with an engine degreaser like GUNK. Allow soaking per the instructions for cleaning an auto engine. Spray clean with water.
2. Operate one dryer without a load to blow hot air through the filter to dry it.
Restart the dryer. Operation should be perfectly normal. It should not be necessary to replace the screen unless it is punctured.