The document is an Excel spreadsheet (Exhibit L) detailing tank and storage facility information for Collin County, Texas, specifically covering three locations: Farmersville Service Center, Collin County Juvenile Justice Center, and Collin County Service Center. The exhibit provides comprehensive details about eight storage tanks across these facilities, including installation dates ranging from 1988 to 2004, tank capacities from 1,000 to 20,000 gallons, and contents such as unleaded gasoline, diesel, asphalt emulsion, and waste oil. The tanks are a mix of underground (UST) and aboveground (AST) storage units, constructed with various materials including steel, fiberglass reinforced plastic (FRP), and concrete, with different wall configurations and leak detection systems.
Concurrently, Collin County is seeking excess liability insurance proposals for a three-year contract with two potential one-year extensions. The county is currently self-insured and is requesting coverage proposals in multiple areas including commercial crime, professional liability, public officials errors & omissions, employment practices, employee benefits administration, law enforcement liability, and pollution coverage. The insurance proposals are sought with specific self-insured retention (SIR) levels: $3,000,000 coverage with SIRs of $1,000,000 and $2,000,000, and $5,000,000 coverage with SIRs of $1,000,000 and $2,000,000. Note that Tank #4 is currently non-operational due to a pipe leak, though it still contains fuel.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Locations
| EXHIBIT NO. 1 | ||||
| Location Number | Name | Address | Facility Type | Own/Lease |
| 1 | Farmersville Service Center | 1269 S State Hwy 78, Farmersville, TX 75442 | Local Government Center | Own |
| 2 | Collin County Juvenile Justice Center | 4600 Community Ave McKinney, TX 75071 | Generator Fueling Facility | Own |
| 3 | Collin County Service Center | 700 A Wilmeth Road McKinney, TX 75069 | Local Government Center | Own |
Tank Info
| EXHIBIT L | |||||||||
| Location | 1 - Farmersville Service Center | 1- Farmersville Service Center | 1- Farmersville Service Center | 2- Collin County Justice Center | 3 - Collin County Service Center | 3 - Collin County Service Center | 3 - Collin County Service Center | 3 - Collin County Service Center | NOTE: Storage Tank #4 is currently not being used due to a leak in the pipe (the leak was not from the tank itself). The tank still has fuel in it. |
| Tank # | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
| Underground/Aboveground | AST | AST | AST | UST | UST | UST | AST | AST | |
| Install Date Year | 1996 | 2004 | 2004 | 1993 | 1988 | 1988 | 2000 | 2004 | |
| Capacity (Gallons) | 6,000 | 9,600 | 9,600 | 20,000 | 6,000 | 12,000 | 1,000 | 9,600 | |
| Contents | Split Product Tank: Unleaded Gasoline- 1,000 Diesel- 5,000 | Asphalt Emulsion | Asphalt Emulsion | Diesel | Unleaded Gasoline | Diesel | Waste Oil | Asphalt Emulsion | |
| Tank Construction Double Walled (DW)/ Single Walled (SW) | DW | SW | SW | SW | SW | SW | DW | SW | |
| Tank Construction Material (DWDM-Double Wall/Double Material) | Steel, Concrete, DWDM | Steel | Steel | FRP (Fiberglass Reinforced Plastic) | FRP (Fiberglass Reinforced Plastic) | FRP (Fiberglass Reinforced Plastic) | Steel, Concrete, DWDM | Steel | |
| Overfill/Spill Protection | Spill Containment Bucket, Level Gauges- High Level Alarms | None | None | Tight Fill, Level Gauges- High Level Alarms, Spill Containment Bucket, Flow shut-off | Tight Fill, Level Gauges- High Level Alarms, Spill Containment Bucket, Flow shut-off | Tight Fill, Level Gauges- High Level Alarms, Spill Containment Bucket, Flow shut-off | Level Gauges- High Level Alarms | None | |
| Tank Leak Detection | Automatic Tank Gauging System | Visual Inspection of AST systems | Visual Inspection of AST systems | Automatic Tank Gauging Systems, Groundwater Monitoring Wells, Tight Fill | Automatic Tank Gauging Systems, Groundwater Monitoring Wells, Tight Fill | Automatic Tank Gauging Systems, Groundwater Monitoring Wells, Tight Fill | Automatic Tank Gauging Systems, Visual Inspection of AST systems | Visual Inspection of AST systems | |
| AST Diking and Base Construction | None | Asphalt Dike | Asphalt Dike | N/A | N/A | N/A | None | Asphalt Dike | |
| Piping Construction (DW or SW) | SW | SW | SW | SW | SW | SW | SW | SW | |
| Piping Construction Material | Steel | Steel | Steel | FRP | FRP | FRP | Steel | Steel | |
| Piping Leak Detection | Visual | Visual | Visual | Interstitial Monitoring in containment pipe | Mechanical Line Leak Detector | Mechanical Line Leak Detector | Visual | Visual |
File details come from the government source that posted it. Updated .