Drawings 3 of 15 CIVIL 2.pdf

PDF 15 MB Posted

Attached to
Y1AZ--TIERED EVALUATIONS - Build New Community Living Center Minor Construction - Montrose 620-334
Solicitation number
36C77623R0156
Issued by

About this file

This document provides details for a federal contract opportunity to construct a new community living center. The solicitation number is 36C77623R0156 for the project "Y1AZ--TIERED EVALUATIONS - Build New Community Living Center Minor Construction - Montrose 620-334" issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity type is a solicitation for bids to perform construction drawings and build a new community living center. The attached file is civil engineering drawing number 3 of 15 that is likely part of the bid package requirements. No other salient details are provided in this document.

View the file

Other files

File Type Posted
620-334-Responses to Tech Questions - 1-30-24.pdf PDF
36C77623R0156 0003.pdf PDF
620-334-Pre Bid Presentation20240109.pdf PDF
36C77623R0156 0002.pdf PDF
620-334-Responses to Tech Questions - 1-25-24.pdf PDF
Site Visit Sign-In Sheet - 01-09-24.pdf PDF
36C77623R0156 0001.pdf PDF
DBA Wage Rates - Westchester County - 01-05-24.pdf PDF
Drawings 8 of 15 ARCHITECTURAL 3.pdf PDF
Site Visit Campus Map.pdf PDF
Drawings 14 of 15 ELECTRICAL 1.pdf PDF
Specifications 10-30-23.pdf PDF
Small Business Subcontracting Plan Model.docx DOCX document
Drawings 5 of 15 STRUCTURAL.pdf PDF
RFP 36C77623R0156 - 12-20-23.pdf PDF
Drawings 12 of 15 PLUMBING.pdf PDF
Drawings 1 of 15 GENERAL.pdf PDF
Drawings 4 of 15 LANDSCAPE.pdf PDF
Drawings 6 of 15 ARCHITECTURAL 1.pdf PDF
Drawings 2 of 15 CIVIL 1.pdf PDF
Drawings 7 of 15 ARCHITECTURAL 2.pdf PDF
Drawings 10 of 15 ARCH SIGN-EQUIP.pdf PDF
Drawings 13 of 15 MECHANICAL.pdf PDF
DBA Wage Rates - Westchester County - 11-17-23.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
Drawings 15 of 15 ELECTRICAL 2.pdf PDF
Brand Name J_A - Montrose.pdf PDF
Site Visit Instructions.pdf PDF
Drawings 11 of 15 FIRE PROTECTION.pdf PDF
Drawings 9 of 15 ARCHITECTURAL 4.pdf PDF
Construction Cost Breakdown.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X

X

X

X

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

X X X X X X X X X X X X X X X X X X X X X

1.20%

115.66

SW

115.36

SW

114.74

SW

113.73

SW

114.76

SW

115.07

SW

115.80

SW

1.54%

2.0 1%

115.80

SW

0.9 9%116.05

SW

114.21

WV

RIM

114.05

RIM

112.45

EX. RIM

114.24

WV

114.24

WV

114.51

EX SW

114.53

EX SW

114.74

SW

112.53

EX. RIM

0.00%

1.85%

115.09

SW

114.07

FL

113.98

FL

114.71

EX. RIM

2.24%

112.73

FL

112.29

FL

115.29

FL

116.17

SW

7.47%

114.37

SW

114.32

SW

1.83%

1.87%

2.3 3%

1.57%

115.17

SW

115.21

SW

0.53%

114.63

SW115.64

SW

115.64

SW

113.80

FL

113.01

EX

0.64%

.00

.00

.00

GRADING LIMITS

114.80

SW

1.00%

0.7 8%

114.84

SW

115.12

SW

115.20

SW

115.43

SW

115.59

SW

115.35

SW

114.85

SW

114.44

SW

113.95

SW

113.87

SW

114.57

SW

114.16

SW

115.26

SW

115.10

SW

114.85

SW

114.69

SW

115.26

SW

114.74

SW

2.0 0%

1.9 9%

2.1 8%

2.0 4%

2.0 0%

2.0 4%

115.78

FL

115.76

FL

115.17

FL

114.59

EX SW

114.58

EX SW

114.58

EX SW

114.15

EX SW

114.12

EX SW

113.99

EX SW

113.70

EX SW

0.5 4%

112.51

EX112.44

EX

112.59

EX112.53

EX

112.47

RIM

LIMITS OF CONSTRUCTION

BACK OF CURB

SIDEWALK

EXISTING NEW

SLOPE AND FLOW DIRECTION (0.50%) 0.50%

STORM DRAIN MANHOLE

SANITARY SEWER MANHOLE

STREET LIGHT

SEWER CLEAN-OUT

STORM DRAIN INLET

FLOW LINE

8' HIGH CONSTRUCTION FENCING X X

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVILGRADING PLAN

ENLARGED VIEW - SHEET 4

CG106

STRUBLEPERKINS

TELECOMMUNICATIONS MANHOLE

CONCRETE - STANDARD BROOM FINISH

CONCRETE - STAINED BROOM FINISH

DECORATIVE LOUVERED FENCE

STRUCTURAL DESIGN CONCRETE

SIDEWALK SCUPPER

EX. A.C. PAVEMENT

PLANTER BOLLARD

PIPE BOLLARD

AND DECORATIVE BOLLARD

F1 CIVIL GRADING PLAN

1"=10'

010' 10' 20'5'

MATCHLINE - SEE SHEET CG105

SURVEY DISCLAIMER

SURVEY INFORMATION OF SITE DETERMINED FROM VA SUPPLIED AS-BUILT DRAWINGS AND ,

PHOTOGRAPHIC, VISUAL, AND LIDAR SURVEY CONDUCTED BY TRIPLE C. CONSTRUCTION HAS

OCCURRED ON THIS SITE SINCE THE SURVEY WAS COMPLETED. CONDITION OF THE SITE MAY

VARY FROM THE SURVEYED CONDITION. UTILITY LOCATIONS ARE IN APPROXIMATE LOCATION.

CONTRACTOR TO PROVIDE UTILITY LOCATION SERVICE PRIOR TO EXCAVATION FOR

VERIFICATION OF LOCATION AND DEPTH OF ALL UTILITIES TO PROVIDE NON-INTERRUPTION OF

SERVICE, TO ENSURE PROPER CLEARANCE/SEPARATION, AND TO AVOID DAMAGE THERETO.

UTILITIES DAMAGED THROUGH NEGLIGENCE OF THE CONTRACTOR TO OBTAIN LOCATION OF

SAME SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE.

NOTE:

THE CONTRACTOR SHALL PROVIDE A "QUALIFIED SWPPP DEVELOPER" (QSD) WHO WILL

BE RESPONSIBLE FOR DEVELOPING A STORMWATER POLLUTION PREVENTION PLAN FOR

THIS PROJECT. THE QSD WILL ACT AS A DATA SUBMITTER FOR THE VA, WITH THE FILING

OF THE NOTICE OF INTENT TO THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL

CONSERVATION FOR COVERAGE UNDER THE CONSTRUCTION GENERAL PERMIT. THE

CONTRACTOR SHALL BE RESPONSIBLE TO PAY ALL FEES ASSOCIATED WITH THIS

PERMIT, WHICH INCLUDE, BUT ARE NOT LIMITED TO, THE NOTICE OF INTENT FILING AND

ANNUAL FEES FOR MAINTAINING COVERAGE UNDER THIS PERMIT. THE CONTRACTOR

WILL BE RESPONSIBLE FOR REVIEWING AND IMPLEMENTING THE PROVISIONS SPECIFIED

IN THE SWPPP AND THE EROSION CONTROL PLANS. THE CONTRACTOR SHALL ALSO

PROVIDE A "QUALIFIED SWPPP PRACTITIONER" (QSP) WHO WILL BE RESPONSIBLE FOR

IMPLEMENTING THE SWPPP, AND WILL ASSIST THE VA IN THE FILING OF A NOTICE OF

TERMINATION TO THE STATE WATER RESOURCES CONTROL BOARD AT THE END OF THE

PROJECT.

EXCAVATION NOTE

CONTRACTOR TO HAND DIG WITHIN 5' OF KNOWN UTILITIES.

DEDUCTIVE ALTERNATES

SEE SHEET CS103 FOR DEDUCTIVE ALTERNATES

CONSTRUCT 6" CONCRETE CURB - SEE DETAIL B1, SHEET CG501

CONSTRUCT 5" CONCRETE SIDEWALK (BROOM FINISH) - SEE DETAIL C5, SHEET CG501

CONSTRUCT ACCESSIBLE RAMP 1 - SEE DETAIL E1, SHEET CG501

CONSTRUCT ENCLOSED WALKWAY - SEE ARCHITECTURAL PLANS F1, SHEET A-101A

CONSTRUCT 3' CONCRETE DRAINAGE SWALE - SEE DETAIL A6, SHEET CG501

CONSTRUCT CONCRETE APRON - SEE DETAIL E3, SHEET CG501

CONSTRUCT 10' HIGH CONSTRUCTION FENCING W/ FABRIC SCREEN - DETAIL E8, CG502

CONSTRUCT CONSTRUCTION YARD ENTRANCE GATE - (2) 6' CENTER LOCKING

CONSTRUCT CONSTRUCTION SIGN - SEE DETAIL F8, SHEET CG501

10 CONSTRUCT UTILITY TRENCH - SEE DETAIL B3, SHEET CG501 FOR DIRECT BURY PIPE

11 CONSTRUCT POROUS PAVEMENT - SEE DETAIL C7, SHEET CG506

12 SAW-CUT EXISTING PAVEMENT OR SIDEWALK

13 CONNECT TO EXISTING - SEE DETAIL A5, SHEET CG501 FOR CONCRETE

14 CONSTRUCT 2' VERT. CURB SEE DETAIL F5, SHEET CG501

15 CONSTRUCT PLANTER BOLLARD / DECORATIVE BOLLARD - SEE DETAIL F1, SHEET LP302

16 CONSTRUCT EMERGENCY ACCESS BARRIER GATE

W/ SIGN "EMERGENCY VEHICLES ONLY" - SEE DETAIL B1, SHEET CG502

17 ADJUST SAN. / STORM SEWER MANHOLE RIM - RAISE TO MATCH NEW GRADE

18 EXISTING UTILITY - PROTECT IN PLACE PER DETAIL B8, SHEET CG501

19 CONSTRUCT 2' DRAINAGE SWALE - SEE DETAIL F8, SHEET CG502

20 CONSTRUCT 48" STORM DRAIN MANHOLE - SEE SHEET CU101

CONSTRUCT 4' GRASS LINED DRAINAGE SWALE - SEE DETAIL F8, SHEET CG502

CONSTRUCT 18"x18" CATCH BASIN - SEE SHEET CU101

- GRADE TOWARDS CATCH BASIN AT 0.50% MIN. SLOPE

ADJUST EXISTING GATE VALVE -VALVE BOX, MATCH FINISH GRADE ELEVATION24

CONSTRUCT MECHANICAL PAD - SEE DETAIL F1, SHEET CG50325

26 CONSTRUCT 5" CONCRETE SIDEWALK (STAINED) - SEE DETAIL C5, SHEET CG501

CONSTRUCT 2' SIDEWALK SCUPPER - SEE DETAIL E7, SHEET CG50327

CONSTRUCT 6" PVC PIPE UNDER SIDEWALK - SEE DETAIL E5, SHEET CG50328

CONSTRUCT STRUCTURAL DESIGN CONCRETE - SEE STRUCTURAL PLANS29

EXISTING TELECOMM MANHOLE - PROTECT IN PLACE30

CAUTION - UNDERGROUND TELECOMM CONDUIT. - PROTECT IN PLACE31

CONSTRUCT 2' CONCRETE "TIP-OUT" CURB - SEE DETAIL C4, SHEET CG50532

GRADE DITCH TO DAYLIGHT36

CONSTRUCT PRE-CAST ELECTRICAL PAD - SEE DETAILS C3, SHEET CG506 37

RE-INSTALL EXISTING SATELLITE DISH, POLE, AND FOUNDATION. COORDINATE WITH COR.

RE-INSTALL EXISTING MINI-PUTT COURSE. COORDINATE WITH COR.

CONSTRUCT 2' CONCRETE DRAINAGE SWALE - SEE DETAIL A6, SHEET CG501

CONSTRUCT 2' CURB OPENING - SEE DETAIL B1, SHEET CG50138

CONSTRUCT ACCESSIBLE RAMP 2 - SEE DETAIL F1, SHEET CG50639

CONSTRUCT DECORATIVE FENCING - SEE DETAIL F6, SHEET CG50540

CONSTRUCT 3' MAN-GATE - SEE DETAIL F6, SHEET CG50541

CONSTRUCT 12' DOUBLE SWING GATES - SEE DETAIL F6, SHEET CG50542

CONSTRUCT PIPE BOLLARD - SEE DETAIL C1, SHEET CG50643

GAZEBO NOT IN SCOPE OF WORK44

- SEE DETAIL C5, SHEET CG506 FOR CONCRETE DUCT BANK

HAND DIG WITHIN 6' OF NEWLY INSTALLED ELEC./TELECOM CONDUIT - SEE SHEET CU101

05/09/2022

EXPIRES: 12/31/24

FSV

W W

W W

W W

W W W

W W

W W

W W

W

W W W

T T

T T

T T

T

T T

T

X X X X X X X X X X X

X

XX

X X

X X

X X

X X

112.73

EX. RIM

114.79

EX. RIM

114.16

EX. RIM

10+00 11+00 12+00

+0

+3

113.01

TC

113.96

TC

112.98

TC

112.89

TC

112.56

TC

112.25

TC

113.94

EX TC

111.49

EX TC

114.81

TC

115.01

TC

115.53

TC

115.52

TC

114.48

FG

114.19

FG

114.83

FG

113.22

FG

112.22

FL

112.55

FL

111.85

FL

112.41

EX

115.68

TC

115.20

TC

114.94

FG

STA:10+00.00

MAIN DRIVE AISLE AT CENTERLINE

N:876296.9132 E:648046.6872

ST

A:1

0+

.50

EN

D T

RA

NS

ITI

ON

1.79%

2.22%

2.06% 1.08%

1.08%

2.0 0%

0.5 0%

114.72

FG

2.0 0%

2.0 0%

0.5 0%

114.64

FL

115.95

TC

115.67

TC

115.32

TC

115.16

TC

113.45

TC113.40

TC

113.38

TC

113.52

SW

112.01

TC

112.05

TC

111.26

EX SW

112.41

SW

112.03

EX SW

113.65

FG

114.39

TC

113.91

TC

114.45

TC

114.99

TC

114.73

FG

115.80

SW

116.25

SW

116.11

SW

115.65

SW

MA

IN

DR

IVE

AI

SL

E A T C

EN

TE

RL

INE

ST

A 1

1+

.20

MAIN DRIVE AISLE AT CENTERLINE

STA 11+77.20

2.00%

1.00%

0.5 0%

4.9 8%

+0

2.7 2%

114.03

SW

114.56

SW

115.11

SW

114.10

EX. RIM

115.83

RIM

+0

13+00

14+00

115.52

TC

116.06

TC

115.58

TC

116.53

TC

116.06

TC

116.13

TC

116.61

TC

116.56

TC

116.08

TC

115.41

TC

116.39

TC

116.32

TC 115.84

TC

115.58

FG

115.82

FG

115.65

FG

115.68

TC

115.20

TC

114.94

FG

2.00%

2.0 0%

0.5 0%

STA

:12

+53 .52

BEG

. V.

C.

STA:14+11.96

END V.C.

115.77

FG

116.51

TC

116.03

TC

114.34

EX. RIM

115.78

RIM

PVI STA: 13+32.74

PVI ELEV: 116.17

K: 100.00

LVC: 158.44

2.0 0%

2.00%

0.50%0.50% 116.50

TC115.95

TC

115.67

TC 116.22

TC

114.99

TC

114.73

FG

116.10

FG

116.05

FG

115.61

FG

115.64

FG

116.43

SW

116.43

SW

115.73

SW

115.73

SW

116.29

SW

116.05

SW

116.66

SW

116.52

SW

116.03

SW

115.80

SW

116.25

SW

116.11

SW

115.81

SW

115.73

SW

115.65

SW

2.0 0%

2.0 0%

0.50%0.50% 0.50% 4.93%4.98%

PVI STA:13+32.74

PVI ELEV:116.17

K:100.00

LVC:158.44

BV

CS

: 1 2+

.52

BV

CE

: 1

.31

EV

CS

: 1 4+

.96

EV

CE

: 1

.77

1.14% 2.06%

1.08%

1.08% -0.50%

-1.55% -4.20%

-2.00%

EXISTING GROUND

PROPOSED GRADEEX

. S

DM

H #

EX

. R

IM

:11 4.3

N:

.77

E:

.83

INV

. IN

: 1

.50

8"

PV

C N E

INV

OU

T:1

.40 8"

CI

P S

E

STA:13+02.15

ELEV:115.70

ADJUST MANHOLE RIM ELEVATION

CONSTRUCT CONCRETE ADJUSTMENT RINGS

ST

A:

+7

7.2

EL

EV

: 1

.48

CL

IN

TE

RS

EC

TIO

N

ST

A:

+0

0.0

EL

EV

: 1

.41

CL

IN

TE

RS

EC

TIO

N

ST

A:

+3

3.9

EL

EV

: 1

.48

CL

IN

TE

RS

EC

TIO

N

ST

A:

+2

1.9

EL

EV

: 1

.72

CL

GR

AD

E B

RE

AK

ST

A:

+6

0.5

EL

EV

: 1

.22

CL

EN

D T

RA

NS

CONSTRUCT CONCRETE APRON

PROPOSED GRADE

EXISTING GROUND

109.74

INV.

109.74

INV.

STA: 10+36.13

EX. WATERLINE

STA: 10+40.13

EX. WATERLINE

110.70

INV.

STA: 10+50.44

EX. TELECOMM

CONDUIT

W

W

W

W

XXXXXXXXXXXXXX

X

+0

15+00 16+00 16+34

114.81

TC

115.01

TC

115.53

TC

115.52

TC

115.41

TC

116.39

TC

116.32

TC

115.84

TC

115.62

TC

116.15

TC

115.36

FG

115.58

FG

114.48

FG

115.65

FG

115.08

FG

114.19

FG

114.83

FG

115.68

TC

115.20

TC

114.94

FG

1.0 8%

2.00%

0.50% 0.50%

0.5 0%

TC

114.72

FG

2.00%

2.00%

0.50%

2.0 0%

1.0 0%

0.50%

0.50%

0.50%

115.09

FL

114.64

FL

115.33

FG

116.50

TC

115.95

TC

115.67

TC

116.22

TC

115.61

TC

115.77

TC

115.32

TC

115.16

TC

114.45

TC

114.99

TC

114.73

FG

116.29

SW

116.05

SW116.66

SW

116.52

SW

116.03

SW

115.80

SW

116.25

SW

116.11

SW

115.81

SW

115.73

SW

115.65

SW

115.73

TC

114.86

FL

115.54

TC

MAIN DRIVE AISLE AT CENTERLINE

STA 11+77.20

MA

IN

DR

IVE

AI

SL

E A T C

EN

TE

RL

INE

ST

A 1

1+

.20

2.0 0%2.0

0%

1.0 0%

0.50% 0.50%0.50%4.93% 4.98%

114.56

SW

115.11

SW

F1 CIVIL STREET PROFILE

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL GRADING

PARKING ACCESS ROAD

PLAN AND PROFILE

CG201

STRUBLEPERKINS

HORIZ. 1"=20' VERT. 1"=2'

020' 20' 40'10'

SURVEY DISCLAIMER

SURVEY INFORMATION OF SITE DETERMINED FROM VA SUPPLIED AS-BUILT DRAWINGS AND ,

PHOTOGRAPHIC, VISUAL, AND LIDAR SURVEY CONDUCTED BY TRIPLE C. CONSTRUCTION HAS

OCCURRED ON THIS SITE SINCE THE SURVEY WAS COMPLETED. CONDITION OF THE SITE MAY

VARY FROM THE SURVEYED CONDITION. UTILITY LOCATIONS ARE IN APPROXIMATE LOCATION.

CONTRACTOR TO PROVIDE UTILITY LOCATION SERVICE PRIOR TO EXCAVATION FOR

VERIFICATION OF LOCATION AND DEPTH OF ALL UTILITIES TO PROVIDE NON-INTERRUPTION OF

SERVICE, TO ENSURE PROPER CLEARANCE/SEPARATION, AND TO AVOID DAMAGE THERETO.

UTILITIES DAMAGED THROUGH NEGLIGENCE OF THE CONTRACTOR TO OBTAIN LOCATION OF

SAME SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE.

LIMITS OF CONSTRUCTION

BACK OF CURB

SIDEWALK

EXISTING NEW

SLOPE AND FLOW DIRECTION

STORM DRAIN MANHOLE

SANITARY SEWER MANHOLE

STREET LIGHT

SEWER CLEAN-OUT

STORM DRAIN INLET

NOTE:

THE CONTRACTOR SHALL PROVIDE A "QUALIFIED SWPPP DEVELOPER" (QSD) WHO WILL BE RESPONSIBLE FOR DEVELOPING A STORMWATER POLLUTION PREVENTION PLAN FOR THIS PROJECT. THE QSD WILL ACT AS A DATA SUBMITTER FOR THE VA, WITH THE FILING OF THE NOTICE OF INTENT TO THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION FOR COVERAGE UNDER THE CONSTRUCTION GENERAL PERMIT. THE CONTRACTOR SHALL BE RESPONSIBLE TO PAY ALL FEES ASSOCIATED WITH THIS PERMIT, WHICH INCLUDE, BUT ARE NOT LIMITED TO, THE NOTICE OF INTENT FILING AND ANNUAL FEES FOR MAINTAINING COVERAGE UNDER THIS PERMIT. THE CONTRACTOR WILL BE RESPONSIBLE FOR REVIEWING AND IMPLEMENTING THE PROVISIONS SPECIFIED IN THE SWPPP AND THE EROSION CONTROL PLANS. THE CONTRACTOR SHALL ALSO PROVIDE A "QUALIFIED SWPPP PRACTITIONER" (QSP) WHO WILL BE RESPONSIBLE FOR IMPLEMENTING THE SWPPP, AND WILL ASSIST THE VA IN THE FILING OF A NOTICE OF TERMINATION TO THE STATE WATER RESOURCES CONTROL

BOARD AT THE END OF THE PROJECT.

FLOW LINE

8' HIGH CONSTRUCTION FENCING

EXCAVATION NOTE

CONTRACTOR TO HAND DIG WITHIN 5' OF KNOWN UTILITIES.

MATCHLINE

C1 CIVIL STREET PLAN

1"=20'

MATCHLINE - STA:12+10.00

MA

TC

HL

INE

- S

TA

:12 +1

0.0

MATCHLINE - STA:14+42.50

MATCHLINE - STA:14+42.50

MATCHLINE -

STA:12+10.00

MA

TC

HL

INE

- S

TA

:14 +4

2.5

MA

TC

HL

INE

- S

TA

:12 +1

0.0

CONCRETE - STANDARD BROOM FINISH

CONCRETE - STAINED BROOM FINISH

DEDUCTIVE ALTERNATES

SEE SHEET CS103 FOR DEDUCTIVE ALTERNATES

1. EXCEPT AS PROVIDED HEREIN, GRADING SHALL BE PERFORMED AT THE ELEVATIONS AND IN ACCORDANCE WITH

THE DETAILS SHOWN ON SHEET CG501-CG506.

2. THE COST FOR REQUIRED CONSTRUCTION DUST AND EROSION CONTROL MEASURES SHALL BE INCIDENTAL TO THE

PROJECT COST.

3. ALL WORK RELATIVE TO FOUNDATION CONSTRUCTION, SITE PREPARATION, AND PAVEMENT INSTALLATION, AS SHOWN ON THIS PLAN, SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "GEOTECHNICAL INVESTIGATION", AS PROVIDED BY THE ARCHITECT OR OWNER. ALL OTHER WORK SHALL, UNLESS OTHERWISE STATED OR PROVIDED FOR HEREON, BE CONSTRUCTED IN ACCORDANCE WITH THE PROJECT, (FIRST PRIORITY) SPECIFICATIONS, AND/OR THE

TOWN OF CORTLANDT, MUNICIPAL CODE (SECOND PRIORITY).

4. EARTH SLOPES SHALL NOT EXCEED 3 HORIZONTAL TO 1 VERTICAL UNLESS SHOWN OTHERWISE.

5. IT IS THE INTENT OF THESE PLANS THAT THIS CONTRACTOR SHALL NOT PERFORM ANY WORK OUTSIDE OF THE

PROPERTY BOUNDARIES EXCEPT AS REQUIRED BY THIS PLAN.

6. THE CONTRACTOR IS TO ENSURE THAT NO SOIL ERODES FROM THE SITE ONTO ADJACENT PROPERTY OR PUBLIC RIGHT-OF-WAY. THIS SHOULD BE ACHIEVED BY CONSTRUCTING TEMPORARY BERMS OR SILT FENCE AT THE

PROPERTY LINES AND WETTING THE SOIL TO PROTECT IT FROM WIND EROSION.

7. A DISPOSAL SITE FOR ANY & ALL EXCAVATION MATERIAL, AND UNSUITABLE MATERIAL AND/OR A BORROW SITE CONTAINING ACCEPTABLE FILL MATERIAL SHALL BE OBTAINED BY THE CONTRACTOR IN COMPLIANCE WITH APPLICABLE ENVIRONMENTAL REGULATIONS AND APPROVED BY VA COR. ALL COSTS INCURRED IN OBTAINING A DISPOSAL OR BORROW SITE AND HAUL TO OR FROM SHALL BE CONSIDERED INCIDENTAL TO THE PROJECT AND NO

SEPARATE MEASURE OR PAYMENT SHALL BE MADE.

8. PAVING AND ROADWAY GRADES SHALL BE +/- 0.1' FROM PLAN ELEVATIONS. PAD ELEVATIONS SHALL BE +/- 0.05'

FROM BUILDING PLAN ELEVATION.

9. DUST CONTROL REQUIRED THROUGHOUT CONSTRUCTION. SPECIAL CONSIDERATION TO BUILDING 5 AND ADJACENT CHILD CARE. SEE SPECIFICATION FOR DUST CONTROL SUBMITTAL REQUIREMENTS. COORDINATE WITH

COR.

05/09/2022

NOT TO SCALE VA STD. SD010000-01F8

VA OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT

U.S. Department of Veterans Affairs

TRIPLE C - THE A/E GROUP, LLC

.00

.00

.00

.00

.00

.00

(GENERAL CONTRACTOR)

NEW COMMUNITY LIVING CENTER

PROJ. NO. 620-19-334

2.0 0'

8.0 0'

2.0 0'

.00

3.0

0' 6.0

0' 3.0

0' 6.0

0' 6.0

0' 6.0

0' 6.0

0' 6.0

0' 6.0

0'

96.00'

CL

1.87' 44.13' 2.00'2.00' 43.87' 2.13'

PROJECT RENDERING

SITE CONSTRUCTION SIGN

PLAN VIEW

2" x 4" FRAMING

4" x 6"POSTS

FACE

96.00'

6.0 0'

4.00'

DEPTH & TYPE OF FOOTING

DETERMINED BY EXISTING

SOIL CONDITIONS.

NOT TO SCALE

PIPE

OD

12"

MIN

MAX

(TYP) 6"

SE

E

SH

EE

T

CU

"U

TI

LIT

Y

SE

PA

RA

TI

ON

N

OT

ES

FO

R

MI

NI

MU

M

CO

VE

R

RE

QU

IR

EM

EN

TS

MI

N

VA

RI

ES

AREAS WITHIN PUBLIC RIGHTS-OF WAY

TRENCH BACKFILL REQUIREMENTS

ABOVE PIPE ZONE - TYPE II AGGREGATE

BASE BACKFILL COMPACTED TO 90% OF

MAX DENSITY, OR CLSM

EXIST GRADE

4" MIN

BEDDING

PIPE ZONE (INCLUDING BEDDING)

PIPE SIZES 24" AND SMALLER:

TYPE II AGGREGATE BASE BACKFILL

COMPACTED TO 90% OF MAX DENSITY,

OR CLSM

PIPE SIZES LARGER THAN 24" CLSM

ONLY (SEE SPECS)

IN AREAS OF EXCESSIVE GROUND WATER OR POOR SUBGRADE MATERIAL,

USE DRAIN BACKFILL SECTION TO A MAXIMUM DEPTH OF 18" FOR

STABILIZATION.

B3

NEW 4" THICK CONCRETE

SLAB-ON-GRADEEXISTING

CONCRETE SLAB

6"

COMPACTED

SUBGRADEEXISTING SUBGRADE,

DO NOT DISTURB

3/8" EXPANSION JOINT

PAD & SEALANT

NO. 4 BARS @ 12" O.C.

DRILL & EPOXY INTO

EXISTING SLAB

6" 6"

NOT TO SCALEA5

NOT TO SCALE VA STD. SD320523-18

NOTES:

1. EXPANSION JOINTS SHALL BE LOCATED WHERE SIDEWALK ABUTS CONCRETE DRIVEWAYS, CURB OR OTHER

ADJACENT STRUCTURES.

2. ONE-HALF INCH BITUMINOUS JOINT FILLER SHALL BE INSTALLED AT EXPANSION JOINT LOCATIONS AND SHALL

EXTEND THE FULL DEPTH OF THE CONCRETE.

3. 1" DEEP CONTRACTION JOINTS SHALL BE PLACED AT INTERVALS OF APPROXIMATELY 15' [4572mm] OR AT A

SPACING THAT MATCHES THE ADJACENT CURB.

4. FORMED CONTRACTION JOINTS SHALL BE FINISHED WITH A TOOL HAVING A 1/4" [6mm] RADIUS.

5. SCORED JOINTS SHALL BE 1/4" [6mm] DEEP AND PLACED AT THE SPACING INDICATED FOR THE WIDTH OF

SIDEWALK OR MATCH SCORED JOINTS OF ADJACENT CURB.

6. CONCRETE SHALL BE FINISHED BY MEANS OF A FLOAT, STEEL TROWELLED AND BROOMED WITH A FINE

BRUSH IN A TRANSVERSE DIRECTION.

7. 1/4" DEEP SCORED JOINTS (TYP) SPACED AT 6' [1829mm] OR EQUAL TO SIDEWALK WIDTH.

1" [25mm]

SCORED OR SAWCUT

CONTRACTION JOINT.

TOP OF CURB

1/4" [6mm] DEEP

SCORED JOINTS

1/4" [6mm] R. (TYP.)

FORMED JOINTS

ONLY

CLASS "B"

CONCRETE

EXPANSION JOINT WITH 1/4"

[6mm] BITUMINOUS JOINT

FILLER

1% MIN. 2%

MAX.

1% MIN.

2% MAX.

5" M

IN

VARIES PER PLANS 0' MIN.

10.5' MAX.

[3200mm]

TYPICAL SECTION

EXPANSION AND SCORED JOINT DETAIL

[5m m]3/1

6"

5" (T

YP

60' MAX.

[18288mm]

EXPANSION JOINT TO EXPANSION JOINT

60' MAX.

[18288mm]

EXPANSION JOINT TO EXPANSION JOINT

SEE NOTE 7

(TYP) PL

AN

S P

ER

P

ER

PL

AN

S

PLAN

'A'

C5

2" [51mm] R.

H=DESIGN REVEAL

NOTES:

1. ALL CONCRETE CURBS AND TRANSITIONS, SHALL HAVE A MINIMUM

COMPRESSIVE STRENGTH OF 2,500 PSI.

2. MAXIMUM SPACING ON SCORED JOINTS SHALL BE 15' [4572mm].

3. 1/2" [13mm] THICK EXPANSION JOINTS SHALL BE LOCATED AT TANGENT

POINTS IN CURB RETURNS, TRANSITIONS, AND AT A MAXIMUM OF 60'

[1828.8cm] INTERVALS. EXPANSION MATERIAL SHALL ALSO BE PLACED

BETWEEN CURBS AND ADJACENT STRUCTURES, SIDEWALKS, DRIVEWAYS

AND CURB ACCESS RAMPS. THE 1/2" [13mm] JOINT FILLER SHALL EXTEND

THE FULL DEPTH OF THE CONCRETE.

4. CONCRETE SHALL BE FINISHED WITH A STEEL TROWEL FOLLOWED BY

BRUSHING WITH A FINE BRUSH ALONG THE LENGTH OF THE CURB OR CURB

AND GUTTER.

5. SINGLE CURB MAY BE CONSTRUCTED BY THE USE OF FORMS OR MAY BE

SLIP FORMED.

6. ALL EXPOSED EDGES AND HAND TOOLED JOINTS SHALL BE FINISHED WITH A

TOOL HAVING A 1/4" [6mm] RADIUS UNLESS A LARGER RADIUS IS INDICATED

BY THE APPLICABLE STANDARD DETAIL OR PROJECT PLANS.

7. FOR REVEALS OF 6" [152mm] TO LESS THAN 8" [203mm].

8. FOR REVEALS OF 8" [203mm] TO 10" [254mm].

6 TO 1 (MAX.)

TOP OF CURB

1/2" [13mm]

BITUMINOUS JOINT

FILLER

3/4" R.

[19mm]

ROADWAY & PAVEMENT

WIDTH

CONCRETE VERTICAL CURB

[241mm]

NOTE 7

9 1/2"

[254mm]

NOTE 8

10"

[40 6m m]

NO

TE

[35 6m m]

NO

TE

6" [152mm]

"H

1:4 CURB

BATTER

CONCRETE CURB TERMINAL SECTION 6"

M

IN

[15 2m m]

PAVEMENT

SURFACE

DESIGN END OF CURB

B1

RAMP CURB HEIGHT TO MATCH

ADJACENT BACK OF SIDEWALK

ELEVATION

ROUGH BROOM FINISH USE RIPPLE

PATTERN

RAMP CURB

8'-0" [2.4m]

8'-0" [2.4m]

SIDEWALK RAMP

GUTTER

1/2" [13mm]

2'-6" [760mm]

MATCH GUTTER

FLOW LINE TC=0"

2' R [609mm]

1/4" R [6mm] TRUNCATED DOME (TYP)

DETECTABLE WARNING STRIP

ROUGH BROOM FINISH

USE RIPPLE PATTERN

2'-6" [760mm]

TRUNCATED DOME DETAIL

ELEVATION

DEPRESSED CURB AT SIDEWALK RAMP

PERSPECTIVE

E1

SIDEWALK

PLAN

LC

SECTION A SECTION B

LC

[2438mm] 8'

[1524mm] 5'

[60 mm

6' [1829mm]

B A A

4' [1219mm]

5' [1524mm]

1' [305mm]

3' [914mm]TOP OF CURBGUTTER

[15 2m m] 6"

PAVEMENT

WALK FLUSH

WITH CURB

1/2" [13mm]

EXPANSION JOINT

B

A

TOP OF CURB

[1524mm] 5'

CU

RB

G

UT

TE

R

4" [102mm] PAINTED

DIAGONAL LINES

LC

1' [305mm]

CROSS SLOPE OF

GUTTER SAME AS

PAVEMENT

2' MODIFIED

CURB &

GUTTER

6" [152mm]

NOT TO SCALEA6

4 #6 Continuous

8"8"

2" C

I

6.5

2' W

ID

TH

6"

3' W

ID

TH

1'-1.5' - PER PLAN CG101

2'-3' - PER PLAN CG101

APPROVED BY THE COR

#4 BARS AT 16" CENTERS,

BOTH WAYS SUPPORTED

BY NON-FERROUS CHAIRS

R = SEE PLAN

SEALANT DETAIL

FINISHED ASPHALT CONCRETE SURFACE TO BE FLUSH WITH CROSS GUTTER LIP.

SECTION A-A

ADJACENT SPANDREL SHALL BE 6" THICK P.C.C.

NOTES:

2.

1.

2" CLR. (TYP.)

3"

6" 6"

C

LR

AGGREGATE BASE

CONCRETE - SEE NOTE NO. 2

A

3/4"

#4 BARS AT 16" O.C.

JOINT DETAIL

1" TYP.

5'-6"

EACH WAY

2" CLR.

12"

3" 3"

SILICONE SEALANT

1'-6"

5/8" BACKING ROD

BOND BREAKER OR

PLAN

2'

"R"

JOINT FILLER

1/2" PREMOLDED EXPANSION

1'-6"

7'

FLOWLINE

A END PLUG. GREASE REINFORCING STEEL

PRIOR TO PIPE INSTALLATION

2'

STANDARD 1/2" PVC PIPE

1/ 4"

1/2"

1/ 4"

E3

E5

BACK OF CURB

PLAN

TYPICAL SECTION

FLOWLINE

WEAKENED

PLANE JOINTS

10' (TYP.)

10'

1"

17"6"

7"

NOTES:

1. 1" BATTER ON GUTTER FACE OPTIONAL.

2. WHERE LONGITUDINAL SLOPE IS LESS THAN

0.4%, THE FLOW LINE SHALL BE WATER

TESTED.

1/2" R

12"

6" 1"

1/4"

1" R

CONCRETE

1/2" R

1"

25"

1-1/2" 4-1/2"

4-1/2" 6"

1-1/2"

SEE

NOTE 1

1/2" EXPANSION JOINT AT ALL COLD JOINTS, AT

BEGINNING AND END OF RETURN AND AT 300'

MAX. INTERVALS FOR EXTRUDED CURB AND 30'

MAX. INTERVALS FOR FORMED CURB.

F5

9' MIN.9' MIN.

5'

8' MIN. 8' MIN.

[2743mm] [2743mm] [2438mm] [2438mm]

1.

2.

3.

ACCESSIBILITY SIGNS WALK4" [102mm] PAINTED DIAGONAL

LINES

[1524mm] 5'

[1524mm] 5'

[1524mm]

SEE SITE AND ENGINEERING DESIGN MANUAL FOR PARKING BAY WIDTHS.

SEE VA BARRIER FREE DESIGN HANDBOOK H-08-13 FOR ACCESSIBLE SPACE QUANTITIES AND

SIGNAGE.

ACCESSIBLE SPACE FOR VANS MUST BE 11' [3300mm] WIDE WITH 5' [1524mm] ACCESS AISLES AND BE

DESIGNATED FOR VANS ONLY.

NOTE:

REGULAR SPACES ACCESSIBLE SPACES

' M

IN

.-2

0'

MA

X.

[54 mm

M

IN

.-6

6m m

MA

X.

[3 m m

CO

MB

IN

AT

IO

N

CU

RB

GU

TT

ER

/W

HE

EL

S

TO

P

PE

R

DE

TA

IL

7-

ACCESSIBILITY SYMBOL4" [102mm] PAINTED PARKING

STALL LINES

F3

6" 6" 3'-

6"

2' 2'

NOT TO SCALEB8

4"x4" WOOD POST

BURIED 6"

4"x4" WOOD CONNECTING

BETWEEN POSTS

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL DETAIL SHEET 1

CG501

STRUBLEPERKINS

GUTTER

NOTES:

1. PROTECTION DETAIL TO BE USED AT ALL ABOVE GROUND

PROTECT IN PLACE LOCATIONS

2. CONTRACTOR TO REMOVE PROTECTION UPON

COMPLETION OF PROJECT OR WHEN APPROVED BY THE

VA COR.

05/09/2022

VA

RI

ES

12"

NOT TO SCALE VA STD. SD260541-04B3

(8

SECTION "A-A"

SECTION "B-B"

SL

OP

E

SLO

PE

SLOPE

VA

RI

ES

(5'-0") 1930mm

(6'-4")

(8") 1524mm

SUMP

305x305mm (12"x12")

203mm

3m m

(6

(1 2"

) M

IN

(8

1524mm (5'-0")

3m m (8 mm (7

'-4

(3") 76mm

(8 '-0

(8

3m m

(9 '-4

(8

3m m mm mm

BB PULLING

IRON

CONC.

ENVELOPE

GROUND ROD

SLEEVE

PULLING

IRON

CABLE STANCHION PER

SECTION 26 05 41.

SUMP 305mm (12")

SUMP FRAME

& COVER

(3 '-0

5m m

915mm (3'-0")

GENERAL NOTE:

INCLUDE ALUMINUM LADDER

(NOT SHOWN FOR CLARITY)

TOP VIEW

965mm965mm (3'-2")

1930mm (6'-4")

(3'-2")

(5 '-6

(3

'-1 0"

(9 '-4 mm mm mm

AA

GROUND ROD PER

SECTION 26 05 26.

GRAVEL SUMP

0.764 CUBIC METERS (1 CUBIC YARD) 19mm

(3/4")

FINISHED

GRADE

GRADE RINGS AS REQ'D TO

MATCH CIVIL FINISHED

GRADE ELEVATION. CABLE

STANCHION

2m m

5m m

3m m

NOT TO SCALE VA STD. SD320523-01C5 NOT TO SCALEC8

1.

2.

3.

4.

5.

NOT TO SCALEF1 NOT TO SCALEF6

NOT TO SCALEE8

FABRIC SCREEN

NOT TO SCALEF8

2.0' - 4.0'

SEE SHEET CG101

4:1 MAX

GRADE TO SIDEWALK

SEE GRADING PLAN CG101

GRADE TO BUILDING

SEE GRADING PLAN CG101

4:1 MAX

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL DETAIL SHEET 2

CG502

STRUBLEPERKINS

NOT TO SCALEB1

NOT TO SCALEC1

EMERGENCY

VEHICLE

ONLY

3"

8"

FENCE AND POST

FINISH GRADE SEE

SHEET CG101

CONCRETE FOOTING

SLOPE TOP

8" DIAMETER - OR AS

REQUIRED BY FENCE

MANUFACTURER

STANDARD

COUPLING

GREASE PIPE ABOVE

COUPLING

-0

" T

OP

O F

FE

NC

E 3'-

0" M

IN

FABRIC SCREEN

-SEE DETAIL C1, THIS SHEET

PIPE BOLLARD

-SEE DETAIL C1, SHEET CG506

4'-0"

SEE SPECIFICATION 26 05 41 SECTION 3.3.D FOR

DUCT CONNECTION TO NEW MANHOLE.

SEE DETAIL C3, THIS SHEET AND SPECIFICATION

26 05 41 SECTION 3.3.E FOR DUCT CONNECTION

TO EXISTING MANHOLE.

BREAK THE STRUCTURE WALL OUT

TO THE DIMENSIONS REQUIRED AND PRESERVE

THE STEEL IN THE STRUCTURE WALL.

CUT STEEL AND EXTEND

INTO THE DUCT BANK ENVELOPE.

CHIP THE PERIMETER SURFACE OF THE

DUCT BANK OPENING TO FORM A KEY

OR FLARED SURFACE,

PROVIDING A POSITIVE CONNECTION

WITH THE DUCT BANK ENVELOPE.

NOT TO SCALEC3

05/09/2022

12" X WIDTH OF LANE

WHITE THERMOPLASTIC STOP BAR

8'-4" WHITE PAINTED "STOP" PAVEMENT MARKINGS

PER BELOW

4'

MI

N.

NOT TO SCALEB3

TYPICAL CROSSWALK

STRIPING DETAIL

2' TYP

10' TYP

2'

TY

P

5' TYP

4' MIN

2' WIDE BARS

TO BE CENTERED

BETWEEN LANE

LINES AND ON

LANE LINES

(TYP)

MEDIAN

ISLAND

(AS APPLICABLE)

LANE LINES

3' MIN

NOT TO SCALEB1

NOTE:

FIELD LEVEL DOME

COVERAGE = 41 POINTS PER

SQUARE INCH

INTERNAL EMBEDMENT FLANGE @ 3"

[76mm] C/C (SEE PLAN FOR

ORIENTATION)

90° POINTS 0.045"

[1mm] HIGH

INTERNAL EMBEDMENT FLANGE @ 3"

[76MM] C/C (SEE PLAN FOR

ORIENTATION)

0.625"Ø HOLE THROUGH EMBEDMENT

FLANGES (3 PER FLANGE) AS SHOWN ON

REFLECTED PLAN

0.625"[16mm]Ø HOLE

THROUGH EMBEDMENT

FLANGES (3 PER FLANGE)

INTERNAL

EMBEDMENT

FLANGE 7 PER

TILE

0.1875"Øx0.0625" DEEP [5mmØx1mm] DOME

UNDERSIDE OF TILE

SECTION B-B

SECTION A-A

DETAILPLAN - TILE REFLECTED PLAN - TILE

[79mm] 3.125"3"

[76mm]

0.1875" [5mm]

3.125" [79mm]

0.1875" [5mm]

0.2 0"

[5m m]

1.3

[35 mm

0.20" [5mm]

0.20" [51mm]

0.45" [11mm]

0.45" [11mm]

1.26" [32mm]

1.67" [42mm]

1.67" [42mm]

24.625" [625mm]

TILE FILLED WITH STRUCTURAL

POLYMER CONCRETE

0.625" [16mm]Ø HOLE

EMBEDMENT FLANGES AS

SHOWN IN PLAN

0.0 6"

[2m m]

0.2 5"

[6m m]

0.3 75"

R [10 mm]

90° POINTS 0.045"

[1mm] HIGH0.20"

[5mm] 0.20"

[51mm] 0.45" [11mm]

0.45" [11mm]

1.26" [32mm]

1.67" [42mm]

1.67" [42mm]

24.625" [625mm]

0.3 75"

R [10 mm]

0.1875" [5mm]

0.1 5" [4m m]

1.3

[35 mm

0.7 0"

[18 mm

0.2 7"

[7m m]

0.9 5"

[24 mm

1.6

7"

2.3 5"

[60 mm]

0.40" [10mm]

1.26" [32mm]

0.0

8" [2m m] 0.9

0" [23 mm

0.4 0"

[10 mm

[42 mm

1.67" [42mm]

0.0

8" [2m m]

0.0

8" [2m m] 0.0

8"

[2m m]

0.0625" [1mm]B B

A

A

1.26" [32mm]

1.26" [32mm]

14 DOMES @ 1.67"

[42mm] SPACING C/C

24.625" [625mm]

1.2 6"

[32 mm

1.2

6" [32 mm

D

OM

ES

1.

[42 mm

] S

PA

CI

NG

C /C

.62

5" [62

5m m]

SEE DETAIL

RIGHT

1.26" [79mm]

3.125" [79mm]

7 FLANGES @ 3"

[76mm] SPACING C/C

24.625" [625mm]

1.8

[5m m] 1.2

6" [32 mm

8.0 0"

[20 3m m]

.62

5" [62

5m m]

8.0 0"

[20 3m m] 0.7

5" [19 mm

0.625" [16mm]

1.238" [31mm]

DETECTABLE WARNING NOTES:

THE DETECTABLE WARNING STRIP MUST COVER THE

ENTIRE WIDTH OF THE RAMP OPENING, EXCLUDING THE

WINGS. ALL DOMES MUST BE ALIGNED IN THE DIRECTION OF

TRAVEL. ONE CORNER OF THE LEADING EDGE OF THE

DETECTABLE WARNING MAY BE MORE THAN 5 FEET FROM

THE BACK OF THE CURB. WHEN LOCATED ALONG A CURB

RETURN, THE LEADING EDGE OF THE DETECTABLE

WARNING MAY BE DEIFNED BY THE CHORD DRAWN

BETWEEN THE LEADING EDGES OF THE RAMP OPENING.

NOT TO SCALE VA STD. SD320523-20C7

MATERIALS:

1. PERFORATED POSTS SHALL BE SQUARE TUBE FORMED FROM 0.105 U.S.S. GAUGE

ASTM A-366 COLD ROLLED CARBON STEEL. THE SQUARE TUBES SHALL BE WELDED

DIRECTLY IN THE CORNER BY HIGH FREQUENCY RESISTANCE WELDING OR EQUAL.

THE POSTS SHALL BE EXTERNALLY SCARFED TO AGREE WITH STD. CORNER RADII OF

5/32" [4mm] TO 1/64" [.3mm].

2. PERFORATED POSTS SHALL BE GALVANIZED TO CONFORM TO ASTM A-525. COATING

DESIGNATION G-90.

3. ALL HARDWARE SHALL CONFORM TO ASTM A-307 CLASS A.

4. ALL HARDWARE SHALL BE GALVANIZED TO CONFORM TO ASTM A-153 OR CADMIUM

PLATED TO CONFORM TO ASTM A-165.

5. ALL CONCRETE SHALL BE 2500 PSI.

NOTES:

1. FOUNDATION WILL BE CONSTRUCTED WITH 1 3/4"x1 3/4" STARTER SIGN POST.

STARTER SIGN POST SHALL BE REMOVED AFTER CONCRETE HAS SET AND EXPOSED

SQUARE TUBING WRAPPED AND SEALED WITH DUCT TAPE.

2. FOUNDATION LOCATED 1' FROM EDGE OF PAVEMENT.

3. FOUNDATION LOCATION TO BE APPROVED BY ENGINEERING.

4. POST FOUNDATIONS SHALL BE PERPENDICULAR TO THE PAVED SURFACE.

5. BOLT WITH NUT AND LOCK WASHER TO BE 7/16"x3" GALVANIZED.

6. REFER TO SIGN POST LOCATION DETAIL, DETAIL 4, THIS SHEET FOR INSTALLATION

LOCATION.

7/16" [10mm] HOLE DIAMETER SPACED AT 1" [25mm] 0.C.

EXPANSION

MATERIAL TYP. IN

CONCRETE AREAS.

FINISH WITH

LANDSCAPE

MATERIAL.

FINISHED

GRADE

4" [100mm]

12" SQUARE

[300mm]

8" [2 m m

2 1 /2"

[6 3m m

[5 0m m

12" SQUARE

[300mm]

2 1 /2"

[6 3m m

[1 m m

]12

[3 m m

2'- 2 1

/2" [6 m m

2'- 8 1

/2" [8 m m

[1 m m

2"x2" [50x50mm]

PERFORATED POST

2 1/4"x2 1/4" [57x57mm]

PERFORATED POST

1 3/4"x1 3/4" [40x40mm]

PERFORATED POST 2'-

9"

[8 m m

8" SQUARE

[200mm]

[2 5m m ] 1

[2 5m m

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL DETAIL SHEET 3

CG503

STRUBLEPERKINS

LIGHT POLE PER LIGHT FIXTURE

SCHEDULE

3"x5" [76x127mm] REINFORCED HAND HOLE

WITH TAMPER RESISTANT SCREWS.

PROVIDE IN-LINE SCREW-TYPE FUSE

HOLDER(S) WITH FUSE(S).

POLE GROUNDING STUD

2-PIECE BOLT COVER PLATE.

PVC CONDUIT ADAPTER COUPLING

PVC CONDUIT

RIGID STEEL CONDUIT

1" EMPTY CONDUIT WITH CAP

(WHERE SHOWN ON PLANS)

FINISHED GRADE

ANCHOR BOLTS PER POLE MANUFACTURER'S

REQUIREMENTS WITH LEVELING NUTS

ABOVE & BELOW BASE PLATE

" [76 mm

2'- 0"

M

IN

[61 0m m]

UNDISTURBED SOIL OR

SELECT BACKFILL

COMPACTED, SEE NOTE

BELOW.

#4 BARE COPPER GROUND

20FT COILED BELOW BASE

CONCRETE BASE &

REINFORCING STEEL, SEE

NOTE BELOW.

NOTE:

BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE SHOWN FOR REFERENCE ONLY.

STRUCTURAL DESIGN IS SHOWN ON STRUCTURAL DRAWINGS.

NOT TO SCALE VA STD. SD265600-02B5

NOT TO SCALE

SIDEWALK

0.50%

0.50%

6" PVC S.D. 0.50% MIN.

4:1MAX.

4:1

MAX.

4'W x 3'L x 6"D - RIVER ROCK D50 = 3" 4'W x 3'L x 6"D - RIVER ROCK

D50 = 3"

6" 6"

E5

SECTION A-A SECTION B-B

NOTES:

1. ( ) INDICATES DIRECTION OF FLOW.

2. DIMENSION 'B' EQUALS 'A'+1' [305mm].

3. 1/2" [13mm] THICK STEEL DIAMOND PLATE ASTM A-36. STEEL

DIAMOND PLATE SHALL BE GIVEN ONE SHOP COAT OF PAINT

NO.1 PER VA SPECIFICATIONS. EXPOSED METAL SHALL BE

PAINTED WITH TWO COATS OF SSPC PAINT NO. 5 PER VA

SPECIFICATIONS.

4. 'H' EQUALS CURB FACE HEIGHT. DIMENSION TO BE NOTED ON

PLANS OR ESTABLISHED IN THE FIELD.

5. FOR CURB AND GUTTER, USE 2' [610mm] TRANSITIONS TO

VERTICAL CURB.

6. FOR MULTIPLE SCUPPERS PROVIDE 4" [100mm] BETWEEN

ADJACENT PANELS OF STEEL DIAMOND PLATE. INTERMEDIATE

POSTS FOR BARRICADE RAILINGS SHALL BE PLACED MIDWAY IN

4" [100mm] AREA BETWEEN ADJACENT PANELS.

7. STEEL DIAMOND PLATE SHALL BE DELIVERED AS ONE PIECE,

CONFORMING TO THE REQUIRED SCUPPER DIMENSIONS.

PLATES SHALL NOT BE SPLICED.

8. PROVIDE A MIN. 1" [25mm] LIP BETWEEN FLOW LINE OF SCUPPER

AND PAVEMENT SURFACE.

LP

LP

VARIES

B

A A

B

EXPANSION JOINT

CURB

6" [150mm]

SIDEWALK

PER PLANS

1' MIN.

[305mm]

1'(

TY

P) [30

5m m]

"(T

YP

[45 5m m]

STEEL

DIAMOND PLATE ASTM

A-36

3/8" [10mm]

FLATHEAD STAINLESS STEEL CAP

SCREW COUNTERSINK (8 EACH MIN.

PER SIDE)

CARRY PLATE TO TOP

FRONT FACE OF CURB

DEPRESSED CURB BARRACADE RAILING

PLAN

SLOPE PER PLANS

VARIES

SLOPE PER PLANS[15

0m m] 6"

[10 0m m]

STEEL DIAMOND PLATE

CLASS "B" CONCRETE 1/4" [6mm] R

SCUPPER FOUNDATION SHALL CONFORM TO STANDARD CURB CROSS

SECTION BELOW PAVEMENT

GUTTER

FLOWLINE

PAVEMENT SERVICE

NO

TE

'H

[760mm]

2'-6" MAX.

'A' 2" 2"

[50mm][50mm]

CLASS "B" CONCRETE

EXPANSION JOINT

(TYP)

[10 0m m]

4"SEE DETAIL

BELOW

[100mm] 4"

[100mm] 4"

[10 0m m] 4"

SEE NOTE 3

[255mm] 10"

'B' (SEE NOTE 2)

1/8" [3mm]

3/8" [10mm] FLATHEAD STAINLESS

STEEL CAPSCREW COUNTERSUNK

(6 EACH SIDE MIN.)

L 2"x2"x1/4" [50x50x6mm]

TYP. BOTH SIDES

#4 [No. 13] REBAR, 4" [100mm]

LONG

3 EACH SIDE MIN.

3/16" [5mm]

DETAIL

(N

OT

E 4)

NOT TO SCALE VA STD. SD320523-08E7

12" 12"

F1 NOT TO SCALE

1.

2.

3.

4.

5.

6.

EQUIPMENT.

MINIMUM 12" THICK

CONCRETE SLAB ON

SUBGRADE.

#5 AT 12" O.C. EACH WAY TOP

AND BOTTOM.

TOOLED EDGE.

EXISTING GROUND

SUBBASE COMPACTED TO 90%

3 2" CL

R

6"

NOTE:

COORDINATE EQUIPMENT PAD

EDGE DIMENSION AND

DIMENSION ABOVE FINISHED

FLOOR REQUIREMENTS WITH

MECHANICAL DRAWINGS.

10" MIN

1'-

CLEAN 3/4" CRUSHED ROCK

8"

3" CL

R8"

24"

#5 BAR @ 24" O.C.

7. GENERATOR PAD TO HAVE 4'

CLEAR ON SERVICE SIDE

05/09/2022

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL DETAIL SHEET 4

CG504

STRUBLEPERKINS

NOT TO SCALEC1

ROOF SLAB REINFORCING DESIGNED

TO WITHSTAND HS-25 LOADING.

1'-0" 8"

48" DIA.

48" DIA. 5"

SEE STEP

DETAIL

8"8"

8"

BASE SECTION

2',3',4' OR 5' HGT.

RISER SECTION

1',2',3' OR 4' HGT.

CONE SECTION

3'-0"(30" OP'N)

5"

12" MAX.

5"

4"

JOINT DETAIL

(TYP.)

BUTYL RUBBER JOINT

SEALANT PER FED'L.

SPEC. NO. SS-S-00210.

STEP DETAIL

12" O.C.

6" MIN.

0.12 SQ. IN. PER LIN. FT. BOTH WAYS.

AREA OF CIRCUMFERENTIAL STEEL

0.12 SQ. IN. PER LIN. FT.

SECTION WITH ROOF SLAB

SECTION WITH CONECOARSE AGGREGATE #57

BY CONTRACTOR IN THE FIELD.

5 7/8"MA INDUSTRIES MODEL #PS2-PF

STEEL REINFORCED COPOLYMER

POLYPROPYLENE PLASTIC STEP(OR

EQUAL) PER ASTM D2146 TYPE II,

GRADE 16906.

EITHER OVERSIZED

HOLES OR SPECIAL

CONNECTIONS INTO

WALLS, ANGLE AND

ELEVATION TO SUIT.

POURED INVERTS (CHANNEL & BENCH) BY A&R AVAILABLE UPON

REQUEST WHEN PIPE SIZE IS 8" DIA.

4'-0" DIAMETER MANHOLES

(CONSEAL MODEL CS-102)

FRAME & COVER SUBMITTAL BY

CONTRACTOR

AREA OF CIRCUMFERENTIAL STEEL

0.12 SQ. IN. PER LIN. FT.

NOTES:

1) DESIGN IN ACCORDANCE WITH AASHTO 17TH ED.

2) LIVE LOAD = A-20 (AASHTO HS25)

3) EARTH FILL FOR DESIGN = 24"

4) CONCRETE STRENGTH = 4,500 PSI

5) REINFORCING STEEL - ASTM A615, GRADE 60

6) WELDED WIRE REINFORCING - ASTM A1064, GRADE 65

SMOOTH.

7) MATERIALS AND MANUFACTURING SHALL CONFORM TO

ASTM C913 .

8) LIFTING AND HANDLING SHALL CONFORM TO OSHA

STANDARDS.

9) PRECAST MANHOLE TO BE CONSTRUCTED AND

REINFORCED IN ACCORDANCE WITH ASTM C-478-90b

MANHOLE REQUIREMENT CHECKLIST:

PIPE TO MH CONNECTOR - □ HOLE THRU

□ BOOT (KOR-N-SEAL)

□ ECONSEAL (EQ. TO A-LOK)

COATING - □ YES;□ INTERIOR, □ BITUMINOUS

□ EXTERIOR, □ EPOXY

□ NO

ROOF OPENING - □ 24" Dia.; □ 30" Dia.

6" BASE EXT. REQUIRED? □ YES; □ NO

4'-0"(24" OP'N)

BASE EXTENSION AS NEEDED FOR BUOYANCY

CONCRETE VERT. CURB

PER VA STD. SD320523-17

SEE DETAIL B1 SHEET CG501

3'

CONC.

SWALE 24.5'

POROUS ASPHALT - PARKING STALLS

SEE DETAIL C7, SHEET CG506

VERTICAL CURB AND

MODIFIED CURB AT CURB OPENING

SEE DETAILS B1 AND E5 SHEET CG501

16.5' 18'

POROUS ASPHALT - DRIVE AISLE

SEE DETAIL C7, SHEET CG506

CONCRETE SWALE

SEE DETAIL A6 SHEET CG501

EXTERIOR BUILDING WALL

FF=116.50'

6"

VARIES - SEE SHEET CS101

5' MIN.

18"x18" CATCH BASIN

SEE DETAIL E5, THIS SHEET

FOR LOCATIONS - SEE SHEET CU101

VARIES - SEE

SHEET CS101

SIDEWALK

WIDTH AND SLOPE

VARY

SEE SHEETS CS101

AND CG101

VARIES

5% MIN

VARIES

FINISHING PIPE ENTRIES:

CONNECTIONS BETWEEN THE STRUCTURE AND PIPE SHALL BE MADE BY

EITHER USING A RESILIENT CONNECTOR MEETING THE REQUIREMENTS OF

ASTM C1478 OR BY COMPLETELY FILLING THE SPACE AROUND EACH PIPE

WITH CONCRETE GROUTING MATERIAL OR CONCRETE REPAIR MATERIAL

POROUS ASPHALT - PARKING STALLS

SEE DETAIL C7, SHEET CG506

05/09/2022

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL DETAIL SHEET 5

CG505

STRUBLEPERKINS

TYPICAL SECTION

NOTES:

1/2" R

6"

6" 1"

1/4"

HOLDING GUTTER

1/2" R

1"

25"

6"

1" R

17"

CONCRETE

1"

1/2"

5-1/2"

SEE NOTE 2

WHERE REQUIRED

FOR DRAINAGE

1. CONTINUOUS NO. 4 BAR REQUIRED IN NOSE OF

MEDIAN ONLY.

2. 1" BATTER ON GUTTER FACE OPTIONAL.

BACK OF CURB

PLAN

FLOWLINE

WEAKENED

PLANE JOINTS

10' (TYP.)

10' 17"6"

7"

1/2" EXPANSION JOINT AT ALL COLD JOINTS, AT

BEGINNING AND END OF RETURN AND AT 300'

MAX. INTERVALS FOR EXTRUDED CURB AND 30'

MAX. INTERVALS FOR FORMED CURB.

C4

PO

ST

A

BO

VE

G

RO

UN

D

OPENING

GATEGATE

GA

TE

AP

PR

OX

0.0 3'

0.1 1'

0.0 5'

LATCH

0.625"-1.5"

LATCH

0.500"-1.656"

HINGE

0.500"-1.656"

HINGE

Opening Gate Post Dimensions

PostPanel

77" 12' 4" x 4" 11GA or 6" x 6" x 3/16"

Opening 3' to 5'

Gate Post Dimensions PostPanel

77" 3" x 3" 11GA

STANDARD

HINGE

ALUMINUM CAP

PO

ST

A

BO

VE

G

RO

UN

D

GATE

OPENING

Ap pr ox

STANDARD LATCH

0.0 5'

0.0 3'

GA

TE

0.1 1'

0.500"-1.656"

HINGE

0.625"-1.5"

LATCH

HARDWARE KIT

PANEL HEIGHT

NUMBER OF BRACKET KITS PER

POST

77"H 3

HORIZONTAL LOUVERS

VERTICAL FLAT

VERTICAL WIRES

0.08" THICK

2" x 11GA

8GA

64 58" (1642mm)

1 2"

(1

3m m)

3 16

(4 .8m m)

TREE PROTECTION SPECIFICATIONS

1. A 6” LAYER OF COARSE MULCH OR WOODCHIPS IS TO BE PLACED BENEATH THE DRIPLINE OF THE PROTECTED TREES.

MULCH IS TO BE KEPT 12” FROM THE TRUNK.

2. A PROTECTIVE BARRIER OF 6' CHAIN LINK FENCING SHALL BE INSTALLED AROUND THE DRIPLINE OF PROTECTED TREE(S). THE FENCING CAN BE MOVED WITHIN THE DRIPLINE IF AUTHORIZED BY THE PROJECT ARBORIST OR C.O.R. BUT NOT CLOSER THAN 2' FROM THE TRUNK OF ANY TREE. FENCE POSTS SHALL BE 1.5” IN DIAMETER AND ARE TO BE DRIVEN 2' INTO THE GROUND. THE DISTANCE BETWEEN POSTS SHALL NOT BE MORE THAN 10'. THIS ENCLOSED AREA IS THE TREE

PROTECTION ZONE (TPZ).

3. MOVABLE BARRIERS OF CHAIN LINK FENCING SECURED TO CEMENT BLOCKS CAN BE SUBSTITUTED FOR “FIXED” FENCING IF THE PROJECT ARBORIST AND C.O.R. AGREE THAT THE FENCING WILL HAVE TO BE MOVED TO ACCOMMODATE CERTAIN PHASES OF CONSTRUCTION. THE BUILDER MAY NOT MOVE THE FENCE WITHOUT AUTHORIZATION FORM THE

PROJECT ARBORIST OR C.O.R..

4. WHERE THE C.O.R. OR PROJECT ARBORIST HAS DETERMINED THAT TREE PROTECTION FENCING WILL INTERFERE WITH THE SAFETY OF WORK CREWS, TREE WRAP MAY BE USED AS AN ALTERNATIVE FORM OF TREE PROTECTION. WOODEN SLATS AT LEAST ONE INCH THICK ARE TO BE BOUND SECURELY, EDGE TO EDGE, AROUND THE TRUNK. A SINGLE LAYER OR MORE OF ORANGE PLASTIC CONSTRUCTION FENCING IS TO BE WRAPPED AND SECURED AROUND THE OUTSIDE OF THE WOODEN SLATS.

MAJOR SCAFFOLD LIMBS MAY REQUIRE PROTECTION AS DETERMINED BY THE C.O.R. OR PROJECT ARBORIST. STRAW WADDLE MAY ALSO BE USED AS A TRUNK WRAP BY COILING THE WADDLE AROUND THE TRUNK UP TO A MINIMUM HEIGHT OF SIX FEET FROM GRADE. A SINGLE LAYER OR MORE OF ORANGE PLASTIC CONSTRUCTION FENCING IS TO BE WRAPPED AND SECURED

AROUND THE STRAW WADDLE.

5. AVOID THE FOLLOWING CONDITIONS. DO NOT:

a. ALLOW RUN OFF OF SPILLAGE OF DAMAGING MATERIALS INTO THE AREA BELOW ANY TREE CANOPY.

b. STORE MATERIALS, STOCKPILE SOIL, OR PARK OR DRIVE VEHICLES WITHIN THE TPZ.

c. CUT, BREAK, SKIN, OR BRUISE ROOTS, BRANCHES, OR TRUNKS WITHOUT FIRST OBTAINING AUTHORIZATION FROM THE C.O.R..

d. ALLOW FIRES UNDER AND ADJACENT TO TREES.

e. DISCHARGE EXHAUST INTO FOLIAGE.

f. SECURE CABLE, CHAIN, OR ROPE TO TREES OR SHRUBS.

g. TRENCH, DIG, OR OTHERWISE EXCAVATE WITHIN THE DRIPLINE OR TPZ OF THE TREE(S) WITHOUT FIRST OBTAINING

AUTHORIZATION FROM THE C.O.R..

h. APPLY SOIL STERILANTS UNDER PAVEMENT NEAR EXISTING TREES.

6. ONLY EXCAVATION BY HAND OR COMPRESSED AIR SHALL BE ALLOWED WITHIN THE DRIPLINE OF TREES. MACHINE

TRENCHING SHALL NOT BE ALLOWED.

7. AVOID INJURY TO TREE ROOTS. WHEN A DITCHING MACHINE, WHICH IS BEING USED OUTSIDE OF THE DRIPLINE OF TREES, ENCOUNTERS ROOTS SMALLER THAN 2”, THE WALL OF THE TRENCH ADJACENT TO THE TREES SHALL BE HAND TRIMMED, MAKING CLEAR, CLEAN CUTS THROUGH THE ROOTS. ALL DAMAGED, TORN AND CUT ROOTS SHALL BE GIVEN A CLEAN CUT TO REMOVE RAGGED EDGES, WHICH PROMOTE DECAY. TRENCHES SHALL BE FILLED WITHIN 24 HOURS, BUT WHERE THIS IS NOT POSSIBLE, THE SIDE OF THE TRENCH ADJACENT TO THE TREES SHALL BE KEPT SHADED WITH FOUR LAYERS OF DAMPENED, UNTREATED BURLAP, WETTED AS FREQUENTLY AS NECESSARY TO KEEP THE BURLAP WET. ROOTS 2” OR LARGER, WHEN ENCOUNTERED, SHALL BE REPORTED IMMEDIATELY TO THE PROJECT ARBORIST, WHO WILL DECIDE WHETHER THE CONTRACTOR MAY CUT THE ROOT AS MENTIONED ABOVE OR SHALL EXCAVATE BY HAND OR WITH

COMPRESSED AIR UNDER THE ROOT. ROOT IS TO BE PROTECTED WITH DAMPENED BURLAP.

8. ROUTE PIPES OUTSIDE OF THE AREA THAT IS 10 TIMES THE DIAMETER OF A PROTECTED TREE TO AVOID CONFLICT

WITH ROOTS.

9. WHERE IT IS NOT POSSIBLE TO REROUTE PIPES OR TRENCHES, THE CONTRACTOR SHALL BORE BENEATH THE DRIPLINE OF THE TREE. THE BORING SHALL TAKE PLACE NOT LESS THAN 3' BELOW THE SURFACE OF THE SOIL IN ORDER TO AVOID

ENCOUNTERING “FEEDER” ROOTS.

10. ANY DAMAGE DUE TO CONSTRUCTION ACTIVITIES SHALL BE REPORTED TO THE PROJECT ARBORIST OR C.O.R. WITHIN

SIX HOURS SO THAT REMEDIAL ACTION CAN BE TAKEN.

11. AN ISA CERTIFIED ARBORIST OR ASCA REGISTERED CONSULTING ARBORIST SHALL BE RETAINED AS THE PROJECT ARBORIST TO MONITOR THE TREE PROTECTION SPECIFICATIONS. THE PROJECT ARBORIST SHALL BE RESPONSIBLE FOR THE PRESERVATION OF THE DESIGNATED TREES. SHOULD THE BUILDER FAIL TO FOLLOW THE TREE PROTECTION SPECIFICATIONS, IT SHALL BE THE RESPONSIBILITY OF THE PROJECT ARBORIST TO REPORT THE MATTER TO THE C.O.R. AS AN ISSUE OF

NON-COMPLIANCE.

12. VIOLATION OF ANY OF THE ABOVE PROVISIONS MAY RESULT IN SANCTIONS OR OTHER DISCIPLINARY ACTION.

MONTHLY INSPECTIONS

IT IS REQUIRED THAT THE SITE ARBORIST PROVIDE PERIODIC INSPECTIONS DURING CONSTRUCTION.

FOUR-WEEK INTERVALS WOULD BE SUFFICIENT TO ACCESS AND MONITOR THE EFFECTIVENESS OF THE TREE PROTECTION

PLAN AND TO PROVIDE RECOMMENDATIONS FOR ANY ADDITIONAL CARE OR TREATMENT.

DO NOT

ENTER:

Tree Protection

Zone

DO NOT

ENTER:

Tree Protection

Zone

NOTES:

1. AREA 1: TREE PROTECTION

ZONE

2. AREA 2: LOWER CANOPY

PROTECTION

3. AREA 3: CRITICAL ROOT ZONE

AND/OR STRUCTURAL ROOT

ZONE PROTECTION

4. 2"x4" WOODEN CRIBBING

ENCIRCLING TREE TRUNK

5. WIRE TIE SECURED TIGHTLY

AROUND WOODEN CRIBBING

DRIP LINE

C7

05/09/2022

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORDSTAMPCONSULTANT

Revisions: Date:

ISSUED FOR

CONSTRUCTIONA/E:

TRIPLE C - The A/E Group 201 E. Jefferson Street, Suite 200 Syracuse, NY 13202 315.484.5958 Mat Perkins

05/09/2022

MEP

550 North Reo Street, Suite 203 Tampa, FL 33609

(813) 289-4700 Nicholas Stephenson, PE

Structural 315 West James Street, Suite 102 Lancaster, PA 17603

(717) 481-2991 Jason Vannoy, SE, PE

Protective Design Specialist 240 West 35th St. Suite 1004 New York, NY 10001

(212) 967-4890 Corrine Tan, SE

620-334

CLC

2094 Albany Post Road, Montrose, NY 10548

NEW COMMUNITY LIVING

CENTER

CIVIL DETAIL SHEET 6

CG506

STRUBLEPERKINS

3.67' 3.13'

3.75' 3.21'

0.69'

0.25'

2.17'

0.75'

0.75'

0.2 5'

2 TON

SWIFT LIFTS

4 TYP.

ROUNDED CONCRETE

SURFACE

HSS 6.000x0.312

CONC. FILLED STEEL

PIPE COLUMN

PAVING OR FINISHED

GRADE

(6) #5 BARS EQUALLY

SPACED; W/ #3 SPIRAL

TIES @12" O.C.; W/ (2) TIES

IN TOP 5" OF THE PIER

3" CLR.

CONCRETE

FOUNDATION

1' - 6"3" C

LR

6" M

IN

6" 3'

- 6

4'

- 0

112.5-750 KVA

APPROX. WEIGHT: 3080 LBS.

GEOTEXTILE CUT FLUSH

WITH TOP OF ASPHALT

CONCRETE CURB

SEE SHEET CG101

POROUS ASPHALT - OPEN GRADED MIX

3 1/2" THICK

HIGH WATER LINE (TYPICAL)

BASE LAYER,

MIN. 3” ASTM NO. 57 STONE TOP (FILTER) LAYER OVER SUB BASE

2” ASTM No. 57 STONE

SUBBASE LAYER,

9" AVG. ASTM No. 2 STONE

GEOTEXTILE FILTRATION FABRIC

ON BOTTOM AND SIDES OF OPEN

GRADED BASE IF REQUIRED BY

THE DESIGN ENGINEER.

Min 24"

SUBBASE EXTENDS BEYOND

CURB TO PROVIDE WORKING

PLATFORM FOR INSTALLATION.

SUBGRADE. PREPARE ACCORDING

TO RECOMMENDATIONS IN

GEOTECHNICAL REPORT.

GEOTEXTILE FILTRATION FABRIC ON BOTTOM

AND SIDES OF OPEN GRADED BASE IF

REQUIRED BY THE DESIGN ENGINEER.

SUBGRADE (DO NOT COMPACT).

1'-0" Min.

SUB BASE LAYER,

9” ASTM NO. 2 STONE

1'-0"

40 MIL HDPE

SMOOTH LINER BAFFLE

1" WEEP HOLES

(INCLUDE IN PARTIAL

AND FULL INFILTRATION

SYSTEMS)

BASE LAYER,

2” ASTM NO. 57 STONE

DESIGN NOTES:

1. DEPTH OF SUBBASE SUBJECT TO SITE SPECIFIC HYDRAULIC AND STRUCTURAL REQUIREMENTS. CONTACT BELGARD COMMERCIAL FOR DESIGN ASSISTANCE.

2. PAVER DIMENSIONS SUBJECT TO ASPECT AND PLAN RATIO REQUIREMENTS BASED ON TRAFFIC LOADING.

3. GEOTECHNICAL ENGINEER NEEDS TO BALANCE STRUCTURAL STABILITY AND SOIL INFILTRATION WHEN RECOMMENDING SUBGRADE CONDITIONS.

4. WHERE THE FILTRATION GEOTEXTILE IS USED, VERIFY WITH THE MANUFACTURER THAT THE MATERIAL IS NOT SUBJECT TO CLOGGING AND MEETS REQUIREMENTS OF AASHTO M-288.

5. ASTM NO. 2 STONE MAY BE SUBSTITUTED WITH NO. 3 OR NO. 4 STONE.

6. STRICTLY PEDESTRIAN APPLICATIONS MAY SUBSTITUTE BASE/SUBBASE LAYERS WITH ONE 6” BASE LAYER OF ASTM NO. 57 STONE.

SLOPE = 15% MAXIMUM

POROUS ASPHALT - OPEN GRADED MIX

4" THICK

UNDISTURBED EARTH

18"

4" 3"

3"

3"4"4"3" 3"

" M

IN

YELLOW PLASTIC WARNING TAPE.

PROVIDE LABEL "HIGH VOLTAGE"

FOR 12.5kV DUCTBANKS.

TYPE II AGGREGATE BASE BACKFILL

COMPACTED TO 90% RELATIVE DENSITY.

FREE FROM LARGE ROCKS AND DEBRIS.

(COMPACTED IN 6" LAYERS).

FINISHED GRADE OR

SURFACE

CONCRETE DUCTBANK.

SEE ELEC. DETAIL E,

SHEET E-501

6" SAND BED.#4/0 BARE CU. GROUND,

FULL LENGTH OF TRENCH

COUPLE -3-1/2*_

COUPLE -4*_

COUPLING OF EXISTING DUCT BANK

NOTES:

1. When a = 3.5 inches use 3-1/2 inch schedule 40 PVC duct and internal joining coupling for 3-1/2 inch I.D. duct.

2. When a=4.0 inches use 4 inch Schedule 40 PVC duct and internal joining coupling for 4 inch I.D.

duct.

3. Use bell ends for 3-1/2 inch and 4 inch Schedule 40 PVC duct as required.

4. Special order Schedule 40 PVC duct and bell ends as required.

5. For split duct applications:

6. Saw cut Schedule 40 PVC duct into two halves or plate SPLT-DCT-_

7. Place around existing cable.

8. Cover saw cut joints with 2 inch wide sealing tape.

9. Band the 2 halves together using plastic straps on 2 foot centers.

REQUIRED MATERIAL: (PER DUCT)

Internal joining coupling - 1 each PVC bell end - 1 each Schedule 40 PVC duct - length as required Plastic straps - 1 each for every 2 feet of PVC split duct.

Sealing tape 2 inch wide - as required.

INSTALLATION OPTIONS:

*C – Cold - New Construction *H – Hot - Around existing cables

EXISTING REBAR TO HAVE EXISTING

CONCRETE REMOVED FOR A MINIMUM

OF 12" WHERE NEW DUCT BANK WILL BE

CONNECTED THE EXISTING DUCTBANK.

ENSURE EMBED WILL MEET PULL OUT

TEST REQUIREMENTS.

MINIMUM 12" EMBED REBAR,

SPLICE OVERLAP.

SEE STRUCTURAL DRAWINGS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION

TO MANHOLE OR

BUILDING

SEE CIVIL PLANS

TO BE CONCRETE

ENCASED

4"-6"

INTERNAL PVC

JOINT COUPLING

ENSURE NO SHARP EDGES

EX. PVC CONDUIT

EXISTING CONCRETE ENCASED DUCT BANK

CHIP EXISTING CONCRETE

SCH.40 PVC CONDUIT

05/09/2022

GV

GV

PIV

CO

CO

CO

CO

CLC

FF=116.50

STAGING AREA

12,500 SF

EXISTING

BUILDING 6

FF=116.90 @

CONNECTING

CORRIDOR

EXISTING WATER LINE AT TUNNEL CROSSING

CONTRACTOR TO VERIFY DEPTH

PROTECT IN PLACE AND/OR RELOCATE TO

MAINTAIN 12" SEPARATION BELOW TUNNEL

SEE ARCH PLANS FOR TUNNEL INFORMATION

CONTRACTOR:

DO NOT ACCESS SITE

THROUGH PARKING LOT

EXISTING UTILITY ENCLOSURE

PROTECT IN PLACE

CONTRACTOR - USE EXISTING

DRIVE FOR ACCESS

EXISTING SECTIONAL SWITCH #11

PROTECT IN PLACE

ELECTRICAL TRANSFORMER

- SEE ELECTRICAL PLANS ES100

NEW TRANSFORMER REQUIRES UPDATE TO SPILL

PREVENTION, CONTAINMENT, AND CONTROL

(SPCC) PLAN. COORDINATE WITH COR.

ELECTRICAL GENERATOR WITH ABOVE

GROUND FUEL STORAGE TANK WITHIN

GENERATOR ENCLOSURE - SEE ELECTRICAL

PLANS ES100

BOTTOM OF GENERATOR DAY TANK TO BE AT

LEAST 1" ABOVE CONCRETE PAD.

EX. WATER

EX

. E

LE

CT

RI

CA

L

EX

. W

AT

ER

EX. WATER

18 8

19 19

20 21

EX. STLT

EX. FH

EXISTING SECTIONAL SWITCH #12

PROTECT IN PLACE

EX. SSMH #12

RIM:110.45

N: 876738.1073 E: 648281.5780

INV IN:96.73 8" DIP (NE)

INV OUT:96.73 8" DIP (SW)

EX. 8" DIP SS @ S=0.60%

EX. SSMH #11

RIM:109.55

N: 876620.5184 E: 648055.7227

INV IN:95.17 8" DIP (NE)

INV OUT:88.25 10" DIP (S)

EX. 8" DIP SS @ S=0.61%

EX. SSMH #10

RIM:112.47

N: 876489.6369 E: 648007.4534

INV IN:87.55 10" DIP (N)

INV OUT:87.55 10" DIP (SE)

EX. 10

" D

IP SS @

S=0.5

0%

EX

. 1

0" D

IP

S

S

S =0

.51

EX. SSMH #9

RIM:109.43

N: 876235.5472 E: 648140.9733

INV IN:86.10 10" DIP NW

INV OUT:86.10 10" DIP SE

EX

. 1

0" D

IP

S

S

S =0

.50

SAN. SEWER C.O.

RIM:116.29

N: 876655.8470 E: 648278.1551

INV OUT:101.50 6" PVC (NW)

SAN. SEWER WYE CONNECTION

RIM:97.20

N: 876719.1626 E: 648245.1906

INV IN:96.48 8" DIP (NE)

INV IN:96.64 6" PVC (SE)

INV OUT:96.48 8" DIP (SW)

.38

LF

6"

P

VC

S

=6 .81

EX. SDCB

RIM:108.02

N: 876733.1410 E: 648140.9398

INV OUT:97.21 8" DIP SE

EX. SDMH #82

RIM:110.18

N: 876709.2511 E: 648184.1219

INV IN:96.72 8" DIP NW

INV OUT:96.65 10" DIP NE

EX. 49-LF 8" DIP SD S=1.00%

EX. SDMH #80

RIM:111.62

N: 876799.7891 E: 648357.4449

INV IN:93.62 10" DIP SW

INV IN:93.79 8" S

INV OUT:90.07 12" DIP NW

EX. 196-LF 10" DIP SD S=1.55%

EX

. 2

-L

F

" D

IP

S D

S= 1.0

4%

EX. SDMH #91

RIM:114.34

N: 876472.7772 E: 648251.8370

INV IN:101.50 8" PVC N

INV OUT:101.40 8" DIP SE

EX. SDMH #90

RIM:112.54

N: 876310.6450 E: 648338.8379

INV IN:100.48 8" DIP NW

INV IN:100.72 8" PVC N

INV OUT:100.48 8" DIP SE

EX

. 1

-L

F 8"

D

IP

S D

S= 0.5

0%

EX

. 2

-L

F 8"

D

IP

S D

S= 0.9

6%

C

EX. SDCO

RIM:116.54

N: 876602.8329 E: 648517.2078

INV OUT:110.20 6" PVC SW

EX. SDMH #95

RIM:116.39

N: 876583.9104 E: 648477.9498

INV IN:109.90 6" PVC NE

INV OUT:109.73 8" PVC SE

43…