Copy of Attachment 0010-SESAME.xlsx
XLSX spreadsheet 23 KB Posted
- Attached to
- Water Storage Distribution System (Solicitation) Federal contract opportunity
- Solicitation number
- W56HZV21R0011
About this file
This document contains details regarding a federal solicitation for water storage and distribution systems. The U.S. Army Contracting Command- Detroit Arsenal intends to procure up to 123 water storage distribution systems with capacities of 100,000 gallons or split capacities of 2 units at 50,000 gallons each. The systems will provide bulk water storage and distribution capabilities to various Army water systems. The water storage distribution systems are comprised of collapsible fabric storage tanks, engine driven centrifugal water pumps, meters, hoses, fittings and nozzles, as well as hypochlorination units. The Army also intends to award an IDIQ contract for up to 150 spare 350 GPM fluid distribution pumps. The Government will award to up to five IDIQ contracts initially for minimum quantity deliveries to be utilized for testing. The single down-selected awardee will receive orders for full production of the water storage distribution systems and associated logistics products. The resulting IDIQ contracts will have a five-year base period and two one-year options. This procurement is set aside entirely for small businesses. Interested parties should contact the named buyer for additional details.
View the file
Other files for this federal contract opportunity
Show all 50
Water Storage Distribution System (Solicitation) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SESAME
| Inputs | Values | Comments | |
| Controls/ Support Structure | Selection | ||
| Run Objectives | Operational Availability | 0.9 | Readiness goal is 90% |
| Minimize On | Cost | Default | |
| Stock Quantities in Parts File | Use Stock Quantities | Default | |
| Redundancy in Parts File | Use Redundancy in Parts File | Default | |
| Retail Lower Bound | Zero Lower Bound | Default | |
| Location of Order Ship Time | Order Ship Time By End Item | Default | |
| Repair Cycle Time By End Item | Repair Cycle Time By Part | Default | |
| Treatment of Piece Part Wait Times | Add | Default | |
| Output Options | Summary, Part Detail, Stocked Items Only | ||
| Wholesale | |||
| Geographical Area | All except other will be run | Run one at a time | |
| Wholesale Fill Rate | 0.9 | GEN Perna | |
| Wholesale Delay | 120 | Default | |
| Buy Years | 1 | Default | |
| Weapon System Densities | Beginning Density | 0 | Build Schedule |
| Year 1 | |||
| Year 2 | |||
| Year 3 | |||
| Year 4 | |||
| Year 5 | |||
| Year 6 | |||
| Year 7 | |||
| End Item Catalogue Data | Value | Comments | |
| FIA Code (MATCAT) | Jen | ||
| End Item Unit Price | Omar | ||
| Provisioning Contract Control | Jen | ||
| Model | Jen | ||
| End Item National Stock Number | Jen | ||
| Apply All Parts to This Item | No | Default no if only 1 end item | |
| Number of End Items Per System | 1 | Likely 1 | |
| Provisioning Control Code | Jen | ||
| EI Parameters | Value | ||
| Calender Time Between Failures | Leave Blank | ||
| Time To Repair End Item | |||
| Unserviceable Return Rate | 0.85 | Default | |
| Piece Part Maximum Availability | 1 | Default | |
| Failure Factor Modifier | 1 | Default | |
| Depot Repair Cycle Time | 90 | Possibly SIAD | |
| Vertical Supply System | Non-Vertical | Default | |
| EI Retail | |||
| Retail Add Criteria | The run objective and lower bound is not SIP | Choice greyed out because of Run Obectives selection | |
| Retail Operating level | The run objective and lower bound is not SIP | Choice greyed out because of Run Obectives selection | |
| Retail Order Ship Time | GSU | 15 | Default |
| DSU | 15 | Default | |
| ORG | 15 | Default | |
| Retail Repair Cycle Time | GSU | 60 | Default |
| DSU | 45 | Default | |
| ORG | 30 | Default |