This document contains a federal contract opportunity solicitation for the procurement of Water Storage Distribution Systems. The U.S. Army Contracting Command- Detroit Arsenal intends to award up to five IDIQ contracts for a minimum quantity purchase of a 125 GPM pump assembly and 350 GPM pump assembly for testing purposes. The test results will be used to select a single IDIQ contract holder to produce maximum quantities of 87 100k GAL WSDS units and 36 split 50k GAL WSDS units, as well as up to 150 spare 350 GPM fluid distribution pumps over a potential five-year base period and two additional option years. The solicitation sets aside this procurement exclusively for small businesses. The resulting contracts will be fixed-price IDIQ agreements. The point of contact is listed as Jon Kaercher of the Department of the Army Materiel Command TACOM Life Cycle Management Command.
View the file
Other files for this federal contract opportunity
Show all 50
Water Storage Distribution System (Solicitation) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Title Page
FOR OFFICIAL USE ONLY (FOUO)
| Contract # TBD |
| WSDS |
| Contractor Name: TBD |
| CDRL | A007 | Rev # | |
| Item Description: | Hazardous Materials Management Report | ||
| Delivery Type: | Draft | ||
| h | |||
| Due Date: | |||
| Submittal Date: |
DISTRIBUTION STATEMENT A – Approved for Public Release; distribution unlimited
(*Distribution Statement A only applies when form is not filled in. Once filled check the Security Class Guide for proper distribution statement/markings)
WARNING - This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751, et seq.) or the Export Administration Act of 1979 (Title 50, U.S.C., App. 2401 et seq.), as amended. Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive 5230.25.
&"Arial,Bold"&8OSHKOSH DEFENSE, LLC – JLTV LRIP / FRP – W56HZV-15-C-0095 &F &G
&"Arial,Bold"&8OSHKOSH DEFENSE, LLC – JLTV LRIP / FRP – W56HZV-15-C-0095 &F &G
&"-,Bold"&14FOR OFFICIAL USE ONLY (FOUO) &P
&"-,Bold"&14FOR OFFICIAL USE ONLY (FOUO) &P
&"-,Bold"&14FOR OFFICIAL USE ONLY (FOUO) &P
HazMat
| Item # | Product Type | Part/Process Description | Vendor / Vendor Product Name | Vendor Part Number | National Stock Number (NSN) | Corresponding Specifications and Standards | Lifecycle Phase | Where Used / Processes | Quantities or Volumes | Embedded on System (Y or N) | Created by System (Y or N) | Anticipated Hazardous Waste | SDS | Special Hazardous Materials Training | Handling, Storage and Disposal Requirements | Alternatives / Trade Offs | Requests for Use of Prohibited Materials |
| NOTES: | Adhesives, Sealants, Cleaners, Greases, Hydraulic Fluid, Paints, Coatings, Oils, Coolant, Fuel, Solvents, Refrigerants, Fire Suppressants, Batteries, etc. | Military or commercial specification associated with the product | Production, Operation, Maintenance and/or Sustainment | Where used on system or what process in production (include part numbers for embedded hazmat) | Provide number of parts impacted or volume of fluid | Embedded examples include cadmium plating on an electrical connector, lead solder on electronics, hex chrome in coating. Something that remains on the system in its hazardous form. | Created by examples include engine emissions and concentrated brines created by water purification systems. | Identify reasonably anticipated hazardous wastes generated during normal O&M and emergency situations | A SDS must be provided for each hazardous material. Embed file or provide numbering system that coordinates with separately-provided SDSs. | Describe special training required. For example, refrigerant requires training and license. | Materials triggering requirements include but are not limited to paint waste, used fluids, batteries, refrigerant, cadmium or hex chrome parts and compressed gases. Includes safety precautions or PPE required for safe handling. |
| If CARC is included, PPE would be required for any cutting, grinding, sanding, welding, etc. of any painted surfaces to prevent exposure to hex chrome. | If OEM plans to request approval for prohibited materials, this column must include alternative materials investigated | Embed or reference any Requests for Use of Prohibited Materials submitted for this hazardous material. Requests for Use of Prohibited Materials must include trade-off analyses for alternative materials considered. | ||||||||||||||
| EXAMPLE | Adhesive | Adhesive, LOCTITE 242 | LOCTITE 242 Threadlocker | --- | 8030-XX-XXX-XXXX | --- | Production | Used on hood assembly | As required | N | N | Empty Tube | SDS-01 | -- | 1) Do not breathe vapors or spray mist. Avoid exceeding the given occupational exposure limits |
2) Do not get in eyes, on skin, or on clothing.
| 3) Disposal should be in accordance with applicable regional, national and local laws and regulations. | No | -- | ||||||||||||||
| EXAMPLE | Lubricating Oil | Lubricating Oil, SAE 15W-40 | Lubrizol 15W40 CC Engine Oil | --- | 9150-XX-XXX-XXXX | MIL-PRF-2104 | Production, Operation and Sustainment | Used in engine | 10 L | N | N | Potentially contaminated used oil. | SDS-02 | -- | 1) Wear safety glasses with side shields (or goggles). |
2) Wear protective nitrile or Neoprene gloves.
| 3) Disposal should be in accordance with applicable regional, national and local laws and regulations. | No | -- | ||||||||||||||
| EXAMPLE | Hardware | Cadmium plating | Cadmium | --- | --- | --- | Production and Sustainment | Cadmium plating is used as a metallic coating on cable and wire harness connectors that mate to GFE. (Provide every part number that contains cadmium). | 50 connectors | Y | N | Used wiring and electrical connectors | SDS-03 | -- | 1) Parts may be considered hazardous waste. |
2) Disposal should be in accordance with applicable regional, national and local laws and regulations.
| 3) Do not cut, grind or torch cadmium connectors. | Alternatives evaluated include zinc-nickel and nickel-Teflon. | -- | ||||||||||||||||
| EXAMPLE | Battery | Lead acid battery | Hawker 6T battery | 23487 | 1234-XX-XXX-XXXX | MIL-PRF-XXX | Production, Operation, Maintenance and Sustainment | Main vehicle battery | 2 batteries | Y | N | Used batteries | SDS-04 | -- | 1) Disposal should be in accordance with applicable regional, national, and local laws and regulations. | No | -- |