View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
High Power Microwave Technological Electromagnetic Susceptibility with Laboratory Applications (HPMTESLA)
BAA 10-RD-03
CALL 0005
Questions and Answers #1
Q1: What might be expected to be classified in the work?
A1: Classified deals with detailed experimental work pertaining to upset phenomena of operational military devices.
Q2: Are the disruptive effects discussed in the BAA meant to imply upset only, or upset and damage?
A2: The disruptive effects, as referred in CALL 0005 of the HMPTESLA BAA, does not include damage. In accordance with the table shown below, we are interested in levels 2,3 and 4; however, focused more in level 4.
Table for Various Levels of High Power Electromagnetic Effects on a System or Equipment (ref: “Installation and Mitigation Guidelines - System-level Susceptibility Assessments for HEMP and HPEM,” International Electrotechnical Commission (IEC) Standard, Electromagnetic Compatibility (EMC) - 61000-5-9 (2008))
| Level |
| Effect |
| Description |
| Duration |
| 5 |
| Damage |
| Damaged system. Hardware must be replaced, or software has to be reloaded |
| Permanent; until maintenance and repair. |
| 4 |
| Upset |
| Manual intervention is required to restore normal system functionality within a tolerable period |
| Until human intervention, after expiration of a set waiting period. |
| 3 |
| Disturbance |
| Effect is still present some time after RF Source is turned off, but system eventually recovers. |
| Sometime after exposure to RF, unless the set waiting period has expired. |
| 2 |
| Interference |
| Effect is present only during illumination |
| During exposure to RF |
| 1 |
| No Effect |
| No disturbances |
| - / - |
| 0 |
| Unknown |
| Unable to determine due to another component or not Observed effects on |
| - / - |
Reference for the table above: "Installation and Mitigation Guidelines - System-level Susceptibility Assessments for HEMP and HPEM,” International Electrotechnical Commission (IEC) Standard, Electromagnetic Compatibility (EMC) - 61000-5-9 (2008))