About this file

Questions and Answers (Q A) 1. Covers questions received from CALL 0005 posting date (23 February 2011) through 08 March 2011.

View the file

Other files for this federal contract opportunity

Other files attached to High Power Microwave Technology and Electromagnetic Susceptibility with Laboratory Applications (HPMTESLA), newest first.
File Type Posted
Call_Announcement.doc DOC document
BAA_10-RD-03 _Amendment_4_ _Attachment.docx DOCX document
CALL_0011 _Q A__1.docx DOCX document
BAA_10-RD-03 _CALL_0011_ _Attachments.pdf PDF
CALL_0009 _Q A__1.pdf PDF
BAA_10-RD-03 _CALL_0009_ _Attachments.pdf PDF
BAA_10-RD-03 _Amendment_3_ _Attachments.docx DOCX document
CALL_0008_Q A__1.pdf PDF
BAA_10-RD-03 _CALL_0008_ _Attachments.pdf PDF
CALL_0007_Q A__1.pdf PDF
CALL_0007_ _Attachments.pdf PDF
CALL 0006 QA 2.pdf PDF
BAA 10-RD-03 CALL 0006 AMENDMENT 02.pdf PDF
CALL 0006 Q A 1.pdf PDF
CALL 0006 Amendment 01 Revised SOO 1.pdf PDF
CALL0006 Attachments.pdf PDF
BAA 10-RD-03 Amendment 02 Attachments.pdf PDF
CALL 0005 Q A 2.pdf PDF
Q A.doc DOC document
Q A.doc DOC document
BAA 10-RD-03 CALL 0005 Attachments.pdf PDF
BAA 10-RD-03 CALL 0004 Attachments.pdf PDF
BAA 10-RD-03 CALL 0003 Attachments.pdf PDF
BAA 10-RD-03 CALL 0002 Attachment.pdf PDF
BAA 10-RD-03 Amendment 01 Attachments.pdf PDF
BAA 10-RD-03 CALL 0001 Attachments.pdf PDF
BAA 10-RD-03 Attachments.pdf PDF
HPMTESLA PresolicitationNotice.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

High Power Microwave Technological Electromagnetic Susceptibility with Laboratory Applications (HPMTESLA)

BAA 10-RD-03

CALL 0005

Questions and Answers #1

Q1: What might be expected to be classified in the work?

A1: Classified deals with detailed experimental work pertaining to upset phenomena of operational military devices.

Q2: Are the disruptive effects discussed in the BAA meant to imply upset only, or upset and damage?

A2: The disruptive effects, as referred in CALL 0005 of the HMPTESLA BAA, does not include damage. In accordance with the table shown below, we are interested in levels 2,3 and 4; however, focused more in level 4.

Table for Various Levels of High Power Electromagnetic Effects on a System or Equipment (ref: “Installation and Mitigation Guidelines - System-level Susceptibility Assessments for HEMP and HPEM,” International Electrotechnical Commission (IEC) Standard, Electromagnetic Compatibility (EMC) - 61000-5-9 (2008))

Level
Effect
Description
Duration
5
Damage
Damaged system. Hardware must be replaced, or software has to be reloaded
Permanent; until maintenance and repair.
4
Upset
Manual intervention is required to restore normal system functionality within a tolerable period
Until human intervention, after expiration of a set waiting period.
3
Disturbance
Effect is still present some time after RF Source is turned off, but system eventually recovers.
Sometime after exposure to RF, unless the set waiting period has expired.
2
Interference
Effect is present only during illumination
During exposure to RF
1
No Effect
No disturbances
- / -
0
Unknown
Unable to determine due to another component or not Observed effects on
- / -

Reference for the table above: "Installation and Mitigation Guidelines - System-level Susceptibility Assessments for HEMP and HPEM,” International Electrotechnical Commission (IEC) Standard, Electromagnetic Compatibility (EMC) - 61000-5-9 (2008))

File details come from the government source that posted it. Updated .