This package includes structural drawings and details for the rehabilitation of a historic lighthouse located at Fort Washington, Maryland. The drawings show proposed repairs and replacements to the building's wood framing members, foundation piers, and sill beams. Replacement details include full section replacements with splices, and partial depth repairs of deteriorated wood members. Foundation pier repairs involve anchoring new sill beams to the existing brick piers with adhesive anchors. The related federal contract opportunity is solicitation number 140P3022R0030 from the National Park Service to perform lighthouse road and rehabilitation work for the National Capital Parks-East office. The solicitation seeks offers for preservation and rehabilitation of the historic lighthouse located at Fort Washington, Maryland in accordance with the specifications and drawings provided.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10/26/21
DETAIL E-2 SILT FENCE ON PAVEMENTDETAIL E- 6 FILTER LOGDETAIL E- 6 FILTER LOG
GENERAL NOTES
1. ALL STRUCTURAL WORK SHALL BE COORDINATED WITH
ARCHITECTURAL AND MECHANICAL DRAWINGS AND SHALL
CONFORM TO THE PROJECT SPECIFICATIONS, INCLUDING THE
2021 INTERNATIONAL BUILDING CODE AND 2021 INTERNATIONAL
EXISTING BUILDING CODE. ALL GOVERNING STANDARDS LISTED IN
THESE NOTES SHALL BE THE EDITION REFERENCED IN THIS
GOVERNING CODE.
2. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING, BRACING,
AND SHEETING AND MAKE SAFE ALL FLOORS, ROOFS, WALLS,
AND ADJACENT PROPERTY AS PROJECT CONDITIONS REQUIRE.
SHORING AND SHEETING SHALL BE DESIGNED BY A REGISTERED
PROFESSIONAL ENGINEER LICENSED IN THE PROJECT
JURISDICTION, HIRED BY THE CONTRACTOR WHO SHALL SUBMIT
SHOP DRAWINGS AND CALCULATIONS FOR REVIEW.
3. DIMENSIONS AND ELEVATIONS OF EXISTING CONSTRUCTION GIVEN
IN STRUCTURAL DRAWINGS ARE BASED ON INFORMATION
CONTAINED IN VARIOUS ORIGINAL DESIGN AND CONSTRUCTION
DOCUMENTS PROVIDED BY THE OWNER, AND LIMITED FIELD
OBSERVATIONS AND MEASUREMENTS. THE CONTRACTOR SHALL
VERIFY ALL INFORMATION PERTAINING TO EXISTING CONDITIONS
BY ACTUAL MEASUREMENT AND OBSERVATION AT THE SITE. ALL
DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE
SHOWN IN THE CONTRACT DOCUMENTS SHALL BE REPORTED TO
THE CO. FOR EVALUATION BEFORE THE AFFECTED
CONSTRUCTION IS PUT IN PLACE.
4. THE CONTRACT DRAWINGS AND SPECIFICATIONS ARE
COMPLEMENTARY. THESE NOTES HIGHLIGHT RATHER THAN
REPLACE THE SPECIFICATIONS CONTAINED IN THE PROJECT
MANUAL.
CONCRETE
1. ALL CONCRETE WORK SHALL CONFORM TO THE ACI FOLLOWING
GOVERNING STANDARDS.
A. AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE
REQUIREMENTS FOR CONCRETE" (ACI 318).
B. ACI "MANUAL OF CONCRETE PRACTICE", LATEST
EDITION.
C. CONCRETE REINFORCING STEEL INSTITUTE (CRSI)
"MANUAL OF STANDARD PRACTICE", LATEST EDITION.
2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE WITH A
MINIMUM COMPRESSIVE STRENGTH OF 4,500 PSI AT 28 DAYS,
MAXIMUM WATER/CEMENT RATIO 0.45, DURABILITY EXPOSURE
CATEGORIES PER ACI 318 "F3", "S0", "P0", AND "C2" UNLESS
OTHERWISE NOTED.
A. CONCRETE MIXES DESIGN SHALL BE PROPORTIONED IN
ACCORDANCE WITH ACI 318 "PROPORTIONING ON THE
BASIS OF FIELD EXPERIENCE AND/OR TRIAL MIXTURES"
AND PREPARED BY A LICENSED TESTING LABORATORY PAID
FOR BY THE CONTRACTOR. SUBMIT MIX DESIGNS FOR
REVIEW.
3. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING
TO ASTM A615, GRADE 60. REINFORCING STEEL SHALL BE
DETAILED ACCORDING TO THE ACI "DETAILS AND DETAILING OF
REINFORCEMENT" (ACI 315).
4. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A1064,
WITH A MINIMUM YIELD STRENGTH OF 65,000 PSI.
5. SHOP DRAWINGS SHALL BE SUBMITTED TO THE CO. FOR REVIEW
AND APPROVAL. NO CONCRETE WORK SHALL COMMENCE
WITHOUT APPROVED SHOP DRAWINGS.
POST-INSTALLED ADHESIVE AND MECHANICAL ANCHORS
1. POST INSTALLED ANCHORAGE SHALL BE INSTALLED BY
QUALIFIED PERSONNEL PER THE MANUFACTURER’S PRINTED
INSTALLATION INSTRUCTIONS (MPII), AS INCLUDED IN THE
ANCHOR PACKAGING, TO INTACT BASE MATERIAL. INSTALLATION
OF ANCHORS SHALL BE CARRIED OUT BY AN INSTALLER
TRAINED TO INSTALL THE SPECIFIED ANCHORS. NOTIFY
ENGINEER OF RECORD PRIOR TO INSTALLATION IF BASE
MATERIAL CONDITION DEVIATES FROM STRUCTURAL DRAWINGS
OR ASSUMPTIONS AND CONDITIONS OF THE MPII. ALL HOLES
SHALL BE DRY AND HAMMER DRILLED UNLESS OTHERWISE
NOTED, AND ALL CONCRETE BASE MATERIAL TO RECEIVE
ADHESIVE ANCHORS SHALL HAVE A MINIMUM AGE OF 21 DAYS.
2. INSTALLATION OF ADHESIVE ANCHORS IN A HORIZONTAL OR
UPWARDLY INCLINED ORIENTATION AND SUPPORTING A
SUSTAINED TENSION LOAD SHALL BE PERFORMED BY A
CERTIFIED ADHESIVE ANCHOR INSTALLER. CERTIFICATION SHALL
INCLUDE WRITTEN AND PERFORMANCE TESTS IN ACCORDANCE
WITH THE ACI/CRSI ADHESIVE ANCHOR INSTALLER
CERTIFICATION PROGRAM OR APPROVED EQUAL. PRIOR TO THE
COMMENCEMENT OF INSTALLING ANCHORS PROVIDE OWNER AND
ENGINEER OF RECORD WITH DOCUMENTED CONFIRMATION THAT
ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL
HORIZONTAL OR UPWARDLY INCLINED ADHESIVE ANCHORS
SUPPORTING SUSTAINED TENSION LOADS ARE TRAINED AND
CERTIFIED.
A. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED
USING THE PISTON PLUG SYSTEM SPECIFIED BY THE
MPII AND PRODUCED BY THE CORRESPONDING
MANUFACTURER FOR THE ANCHOR SYSTEM BEING
INSTALLED.
3. EXISTING REINFORCING BARS IN THE STRUCTURE MAY
CONFLICT WITH SPECIFIC ANCHOR LOCATIONS. REINFORCING
BARS SHALL NOT BE CUT WITHOUT THE WRITTEN APPROVAL OF
THE ENGINEER OF RECORD. UNLESS NOTED ON THE
DRAWINGS THAT THE EXISTING REBARS CAN BE CUT, THE
CONTRACTOR SHALL REVIEW THE EXISTING STRUCTURAL
DRAWINGS AND SHALL UNDERTAKE TO LOCATE THE POSITION
OF THE REINFORCING BARS BY A MEANS APPROVED BY THE
ENGINEER OF RECORD.
4. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN
ADJACENT ANCHORS, PROXIMITY OF ANCHORS TO EDGE OF
CONCRETE, AND EMBEDMENT DEPTH INTO THE SUBSTRATE.
INSTALL ANCHORS IN ACCORDANCE WITH SPACING, EDGE
CLEARANCES, AND EMBEDMENT DEPTHS INDICATED ON THE
DRAWINGS.
5. UNLESS OTHERWISE INDICATED, POST INSTALLED ANCHORAGE
SHALL BE ADHESIVE TYPE HILTI HIT-HY 200-R INTO
CONCRETE OR HILTI HIT-HY270 INTO BRICK MASONRY, GROUT
FILLED CMU OR UNGROUTED CMU BASE MATERIAL. PROVIDE
MESH SCREEN IN UNGROUTED CMU, UNREINFORCED MASONRY
CONSTRUCTION, AND BRICK MASONRY WITH HOLES OR VOIDS.
6. SUBSTITUTION REQUESTS FOR ALTERNATE ANCHORAGE
PRODUCTS SHALL BE SUBMITTED TO ENGINEER OF RECORD
FOR REVIEW AND APPROVAL PRIOR TO USE. THIS SHALL
INCLUDE MANUFACTURER PRODUCT DATA AND CALCULATIONS
DEMONSTRATING THAT THE PROPOSED SUBSTITUTE CAN
ACHIEVE THE PERFORMANCE VALUES OF THE SPECIFIED
PRODUCT. ANCHOR CAPACITY USED IN DESIGN SHALL BE
BASED ON THE TECHNICAL DATA PUBLISHED BY THE
MANUFACTURER OR SUCH OTHER METHOD AS APPROVED BY
THE ENGINEER OF RECORD. SUBSTITUTIONS WILL BE
EVALUATED BY THEIR HAVING AN ICC-ES EVALUATION REPORT
SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE,
SEISMIC USE, LOAD RESISTANCE, INSTALLATION CATEGORY, AND
AVAILABILITY OF MPII. ADHESIVE ANCHOR EVALUATION WILL ALSO
CONSIDER CREEP, IN-SERVICE TEMPERATURE AND
INSTALLATION TEMPERATURE AND MUST PROVIDE INFORMATION
ON THESE ITEMS. SUBSTITUTION REQUESTS FOR ALTERNATE
PRODUCTS MUST BE APPROVED IN WRITING BY THE ENGINEER
OF RECORD PRIOR TO USE.
FRAMING LUMBER
1. ALL FRAMING LUMBER WORK SHALL CONFORM TO THE FOLLOWING
GOVERNING STANDARDS:
A. AMERICAN WOOD COUNCIL "NATIONAL DESIGN SPECIFICATION
FOR WOOD CONSTRUCTION","NDS SUPPLEMENT: DESIGN
VALUES FOR WOOD CONSTRUCTION", AND "SPECIAL DESIGN
PROVISIONS FOR WIND AND SEISMIC".
2. FRAMING LUMBER SHALL HAVE EACH PIECE GRADE STAMPED, SHALL
BE SURFACED DRY, MILLED AND SAWN TO MATCH THE PROFILE OR
EXISTING LUMBER TO BE REPLACED OR REPAIRED, AND SHALL
CONFORM TO THE FOLLOWING SPECIES AND GRADE: DOUGLAS FIR-
LARCH #1, SPRUCE PINE FIR #1, OR HEM FIR #1
3. TIMBER SHALL BE MILLED AND SAWN TO MATCH THE SIZE OF
EXISTING MEMBERS TO BE REPLACED OR REPAIRED. EXTERIOR
EXPOSED FACES SHALL BE SURFACED. TIMBER SPECIES AND GRADE:
DOUGLAS FIR-LARCH #1, EASTERN WHITE PINE #1, OR SOUTHERN
YELLOW PINE #1. TIMBER SHALL BE DRIED IN A KILN TO A MAXIMUM
MOISTURE CONTENT OF 19%. TIMBERS SHALL BE FREE OF HEART
CENTER.
4. PRESERVATIVE-TREATED WOOD: PROVIDE TREATED LUMBER COMPLYING
WITH ACQ-D (CARBONATE). COPPER AZOLE (CA-B), OR SODIUM
BORATE (SBX (DOT) WITH NaS10/2) AT ALL STRUCTURAL LUMBER
OR AS OTHERWISE INDICATED ON ARCHITECTURAL OR STRUCTURAL
DRAWINGS. ACZA TREATMENT IS NOT PERMITTED. TREATED LUMBER
AND/OR PLYWOOD SHALL BEAR THE LABEL OF AN ACCREDITED
AGENCY SHOWING 0.40 PCF RETENTION. WHERE LUMBER AND/OR
PLYWOOD IS CUT OR DRILLED AFTER TREATMENT, THE TREATED
SURFACE SHALL BE FIELD-TREATED WITH COPPER NAPTHENATE (THE
CONCENTRATION OF WHICH SHALL CONTAIN A MINIMUM OF 2%
COPPER METAL) BY REPEATED BRUSHING, DIPPING, OR SOAKING
UNTIL THE WOOD ABSORBS NO MORE PRESERVATIVE. REFER TO
NOTES 2 AND 3 FOR SPECIES AND GRADE OF TIMBER, UNLESS
OTHERWISE NOTED ON PLAN.
5. FASTENING SHALL BE IN ACCORDANCE WITH THE 2021
INTERNATIONAL BUILDING CODE AND THE 2021 INTERNATIONAL
EXISTING BUILDING CODE.
6. ALL FASTENERS SHALL BE HOT-DIP GALVANIZED OR STAINLESS
STEEL.
7. NO NEW OR EXISTING JOISTS SHALL BE CUT OR NOTCHED WITHOUT
APPROVAL.
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
NACE 899
177009
REHABILITATE
HISTORIC LIGHTHOUSE AT FORT WASHINGTON
251994D
10/26/2021 14
GENERAL STRUCTURAL
NOTES
S0.1
SILMAN
SILMAN
SILMAN
10/21/2021
S3.1
S3.2
S3.1
S3.2
FOUNDATION PIER
REPAIRS, SEE
/3 S5.1
S3.1
S3.1
S3.2
S3.2
S3.1
S3.1
S3.2
S3.2
S3.1
S3.1
S3.2
S3.2
REPLACE FULL SECTION IN-KIND
& SPLICE TO EXISTING, SEE
DETAIL
PARTIAL-DEPTH REPAIR, SEE
DETAIL
LEGEND - FRAMING REPAIRS
/1 S5.1
/2 S5.1
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
NACE 899
177009
REHABILITATE
HISTORIC LIGHTHOUSE AT FORT WASHINGTON
251994D
10/26/2021 14
FLOOR FRAMING PLANS
S1.1
SILMAN
SILMAN
SILMAN
SCALE OF FEET
2 420
SCALE AS1.1
1 1ST FLOOR FRAMING PLAN
SCALE AS1.1
2 2ND FLOOR FRAMING PLAN
SCALE AS1.1
3 LOW ROOF FRAMING PLAN
SCALE AS1.1
4 HIGH ROOF FRAMING PLAN
SCALE A
1/2" = 1'-0"
2ND FLOOR
EL. 14' - 0"
1ST FLOOR
EL. 0' - 0"
LOW ROOF
EL. 21' - 8"
HIGH ROOF
EL. 30' - 0"
3x12 BEAM
3x8 BEAM
3x6 BEAM
FOUNDATION
PIER REPAIRS,
SEE 3/S5.1
2x6 WALL
STUDS,
TYPICAL
2ND FLOOR
EL. 14' - 0"
1ST FLOOR
EL. 0' - 0"
LOW ROOF
EL. 21' - 8"
HIGH ROOF
EL. 30' - 0"
FOUNDATION
PIER REPAIRS,
SEE 3/S5.1
2x6 WALL
STUDS,
TYPICAL
3x14 BEAM
REPLACE FULL SECTION IN-KIND
& SPLICE TO EXISTING, SEE
DETAIL
PARTIAL-DEPTH REPAIR, SEE
DETAIL
LEGEND - FRAMING REPAIRS
/1 S5.1
/2 S5.1
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
NACE 899
177009
REHABILITATE
HISTORIC LIGHTHOUSE AT FORT WASHINGTON
251994D
10/26/2021 14
SECTIONS
S3.1
SILMAN
SILMAN
SILMAN
SCALE AS3.1
1 SECTION LOOKING NORTH
SCALE AS3.1
2 SECTION LOOKING SOUTH
NOTES:
1. FOR PRICING BID, ON NORTH ELEVATION INCLUDE ADDITIONAL ALLOWANCE TO REPAIR 10% OF
ALL FRAMING WITH PARTIAL DEPTH REPAIR AND 5% OF ALL FRAMING SHOWN WITH IN-KIND
REPLACEMENT. PERCENTAGES SHALL BE BASED ON LENGTH OF MEMBERS CATEGORIZED INTO
EACH FRAMING SIZE.
NOTES:
1. FOR PRICING BID, ON SOUTH ELEVATION INCLUDE ADDITIONAL ALLOWANCE TO
REPAIR 5% OF ALL FRAMING WITH PARTIAL DEPTH REPAIR AND 5% OF ALL
FRAMING SHOWN WITH IN-KIND REPLACEMENT. PERCENTAGES SHALL BE BASED
ON LENGTH OF MEMBERS CATEGORIZED INTO EACH FRAMING SIZE.
SCALE OF FEET
2 60 2 4
SCALE A
3/8" = 1'-0"
2ND FLOOR
EL. 14' - 0"
1ST FLOOR
EL. 0' - 0"
LOW ROOF
EL. 21' - 8"
HIGH ROOF
EL. 30' - 0"
0"
2x6 WALL
STUDS,
TYPICAL
FOUNDATION
PIER REPAIRS,
SEE 3/S5.1
REPLACE FULL SECTION IN-KIND
& SPLICE TO EXISTING, SEE
DETAIL
PARTIAL-DEPTH REPAIR, SEE
DETAIL
LEGEND - FRAMING REPAIRS
/1 S5.1
/2 S5.1
2ND FLOOR
EL. 14' - 0"
1ST FLOOR
EL. 0' - 0"
LOW ROOF
EL. 21' - 8"
HIGH ROOF
EL. 30' - 0"
2x6 WALL
STUDS,
TYPICAL
FOUNDATION
PIER REPAIRS,
SEE 3/S5.1
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
NACE 899
177009
REHABILITATE
HISTORIC LIGHTHOUSE AT FORT WASHINGTON
251994D
10/26/2021 14
SECTIONS
S3.2
SILMAN
SILMAN
SILMAN
SCALE AS3.2
1 SECTION LOOKING EAST
SCALE AS3.2
2 SECTION LOOKING WEST
SCALE OF FEET
2 60 2 4
SCALE A
NOTES:
1. FOR PRICING BID, ON EAST ELEVATION INCLUDE ADDITIONAL ALLOWANCE TO REPAIR 5% OF
ALL FRAMING WITH PARTIAL DEPTH REPAIR AND 5% OF ALL FRAMING SHOWN WITH IN-KIND
REPLACEMENT. PERCENTAGES SHALL BE BASED ON LENGTH OF MEMBERS CATEGORIZED INTO
EACH FRAMING SIZE.
NOTES:
1. FOR PRICING BID, ON WEST ELEVATION INCLUDE ADDITIONAL ALLOWANCE TO
REPAIR 5% OF ALL FRAMING WITH PARTIAL DEPTH REPAIR AND 5% OF ALL
FRAMING SHOWN WITH IN-KIND REPLACEMENT. PERCENTAGES SHALL BE BASED
ON LENGTH OF MEMBERS CATEGORIZED INTO EACH FRAMING SIZE.
3/8" = 1'-0"
HALF-LAP SPLICE IN TIMBER FASTENED
W/ (2) 1" STAINLESS STEEL BOLTS
BEARING ENDS OF SPLICE SHALL BE SQUARE
AND TIGHT ON BOTH ENDS (NO GAPS)
SECTION OF EXISTING FRAMING TO REMAIN
NEW FRAMING REPLACING EXISTING
DETERIORATED FRAMING (SEE PLAN AND
SECTIONS)
M
IN
M
IN
M
IN
SECTION ELEVATION
NEW WOOD TO REPLACE ROTTED WOOD,
FASTENED TO EXISTING WITH ANSI/HPVA TYPE I
SPECIFICATION EXTERIOR PVA WOOD GLUE AND
#10 STAINLESS STEEL SCREWS AT 4" O.C.,
EMBED SCREW MIN. 2" IN EXISTING WOOD TO
REMAIN
EXISTING WOOD TO REMAIN
NOTES:
1. CONTRACTOR SHALL FIELD VERIFY DEPTH OF ROTTED WOOD. FOR
PRICING BID ASSUME DEPTH OF "d/2".
2. IF DEPTH OF ROT IS LESS THAN 1/2 OF MEMBER'S DEPTH, RIP
FACE OF EXISTING WOOD TO CUT ROT FROM SECTION AND REPLACE
WITH NEW WOOD AS SHOWN.
3. IF DEPTH OF ROT EXCEEDS 1/2 OF MEMBER'S DEPTH, REPLACE
FULL SECTION OF MEMBER.
EXTERIOR FACE OF STUD
INTERIOR FACE OF STUD
EXTERIOR SHEATHING, SEE ARCH.
"d
"d M A X
END OF EXISTING STUD (BOTTOM OR TOP)
1 1/2"
EXISTING MEMBER BEYOND REPAIR
WHERE PARTIAL DEPTH REPAIR DOES NOT
TERMINATE AT END OF STUD, PROVIDE HALF
LAP SPLICE W/ (3) 1/2" STAINLESS STEEL
CARIAGE BOLTS; RECESS HEAD FLUSH W/
EXTERIOR FACE.
EXISTING SHEATHING, SEE ARCH. FOR
REPLACEMENT & REFININSHING
EXISTING STUDS, POSTS, AND BRACES
EXISTING SILL BEAMS
ANCHOR EACH SILL BEAM INTO BRICK
PIER WITH 1/2" STAINLESS STEEL
ADHESIVE ANCHORS W/ 12"
EMBEDMENT INTO CONCRETE AND
BRICK. CAP HOLE W/ GLUED PLUG.
REPLACE EXISTING WOOD PLINTH W/ NEW
PRECAST CONCRETE MEMBER W/
GALVANIZED 6x6 W2.1xW2.1
REINFORCEMENT OR EQUIVALENT. PLINTH
SIZE TO MATCH EXISTING. SEE GENERAL
NOTES FOR CONCRETE REQUIREMENTS.
SEE ARCH. FOR FLASHING & WATERPROOFING
EXISTING BRICK PIER
1 1/2"
SUB SHEET NO. TITLE OF SHEET
OF
DATE:
TECH. REVIEW:
DESIGNED: DRAWING NO.
PMIS/PKG NO.
SHEET
NACE 899
177009
REHABILITATE
HISTORIC LIGHTHOUSE AT FORT WASHINGTON
251994D
10/26/2021 14
DETAILS
S5.1
SILMAN
SILMAN
SILMAN
SCALE AS5.1
1 SPLICE AT FULL-SECTION WOOD MEMBER REPLACEMENT
SCALE AS5.1
2 PARTIAL DEPTH WOOD REPAIR
SCALE BS5.1
3 FOUNDATION PIER REPAIRS
SCALE OF FEET
1 210
SCALE OF FEET
12 126 0
SCALE A
SCALE B
1-1/2"=1'-0"
1"=1'-0"
| Sheets |
| S0.1 - GENERAL STRUCTURAL NOTES |
| S1.1 - FLOOR FRAMING PLANS |
| S3.1 - SECTIONS |
| S3.2 - SECTIONS |
| S5.1 - DETAILS |