B01 RFP Attachment J01a Drawings (2).pdf
PDF 5 MB Posted
- Solicitation number
- 75H70126R00004
About this file
These documents are architectural and engineering design drawings for the Kyle Clinic Health Center Addition project located in Kyle, South Dakota, prepared by TSP, Inc. in April 2017. The project involves a comprehensive renovation and expansion of an existing healthcare facility, with multiple detailed sets of drawings covering structural, mechanical, electrical, and lightning protection systems.
Key technical details include a new first-level addition with various medical spaces like exam rooms, dental operatories, nursing areas, and support spaces. The mechanical systems feature an air handling unit (AHU-1) with 3,135 CFM airflow, variable air volume (VAV) terminal units, and hydronic piping. The electrical design includes a new electrical distribution system with panels, a generator, and automatic transfer switches. The lightning protection plan covers comprehensive grounding and bonding methods for the building, with air terminals, conductors, and connections designed to protect the facility from electrical hazards. The project appears to be for the Indian Health Service (IHS) and involves upgrading and expanding the existing Dakota Plains Kyle Clinic Health Center.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FO
R
D
EP
TH
R
EF
S
C
HE
DU
LE
REF MASONRY LINTEL
SCHEDULE FOR REINF
REINF AND GROUT
CORES FULL HGT- REF
SCHEDULE FOR JAB CONSTR
2"
CONTROL JOINT WHERE
INDICATED ON ARCH DRAWINGS
END WALL & JAMBS CORNER
3000 PSI
CONC
1-#5 BAR
C BLOCKL
REF GENERAL NOTES FOR
SIZE & SPACING OF REINF.
REINF SHALL BE DOWELED
INTO FOOTING OR
FOUNDATION WALL
MASONRY LINTEL SCHEDULE
MARK DESCRIPTION DETAIL REMARKS
L1
ADDITIONAL REMARKS:
1. PROVIDE MIN. 8" BEARING AT ALL STEEL LINTELS, UNO (REF DETAIL B3/S-501)
2. EXTEND CMU LINTEL REINF PAST OPNG THRU ALL GROUT FILLED CORES OF JAMBS (REF DETAIL B5/S-501)
3. REFERENCE GENERAL STRUCTURAL NOTES ON S-001 FOR TYPICAL LINTELS FOR MECH, ELEC, AND OTHER OPENINGS NOT SHOWN. COORD OPENING SIZES AND LOCATIONS WITH MECH, ELEC AND ARCH.
4. GROUT MASONRY LINTELS FULL.
5. DO NOT PLACE CONDUIT WITHIN MASONRY LINTELS.
6. GALVANIZE ALL EXTERIOR STEEL LINTELS.
2" 16 " D
EE
P
PROVIDE FULL HGT JAMBS EA SIDE
W/ (2) FULLY GROUTED CORES
W/ (1) #5 PER CORE
16" DEEP LINTEL
REINF w/ (2) #4
L2
2" 24 " D
EE
P
24" DEEP LINTEL
REINF w/ (2) #4
PROVIDE FULL HGT JAMBS EA SIDE
W/ (2) FULLY GROUTED CORES
W/ (1) #5 PER CORE
D S
2S
D
CONT REINF TO
MATCH CONT
FTG REINF
SLEEVE THROUGH WALL MIN 2"
LARGER DIA THAN PIPE
-REF PLAN FOR LOCATIONS
-INSULATE AROUND PIPE
M
IN6"
MIN
6"
3" M
IN
BRG
6"
CMU WALL
(REF PLAN)
PROVIDE BACKER ROD
AT END OF ANGLE TO
ALLOW MOVEMENT
PROVIDE BOND BREAKER
BETWEEN BOTTOM OF
LINTEL AND MORTAR
INSTALL FLEXIBLE JOINT
SEALANT AND BACKER ROD
BRICK ANGLE
(REF PLAN)
CONTROL JOINT
AS OCCURS
EXT NON-BRG BRICK/CMU
ANGLE SCHEDULE
SPAN STEEL ANGLE REMARKS
6'-4" AND SMALLER
6'-5" TO 8'-4"
ADDITIONAL REMARKS:
1. ALL LINTELS TO BEARING A MINIMUM OF 6" ON SOLID MASONRY.
2. REFERENCE DETAIL A5/S-501 FOR BEARING CONDITIONS AT CONTROL JOINTS. REFERENCE ARCH FOR
CONTROL JOINT LOCATIONS.
3. GALVANIZE ALL EXTERIOR LINTELS.
L4x4x1/4"
L6x4x3/8" (LLV)
VERTICAL LEG OF ANGLE BACKED
UP TO EXTERIOR FACE OF CMU
VERTICAL LEG OF ANGLE BACKED
UP TO EXTERIOR FACE OF CMU
BEAM/COLUMN
ADDITIONAL REMARKS:
1. FOR CONNECTIONS SHOWN IN THIS SCHEDULE THE SUPPORTED MEMBER SHALL HAVE A MAXIMUM TOP COPE OF 2" DEEP AND 6" LONG. MINIMUM HORIZONTAL EDGE DISTANCE TO THE CENTER OF THE BOLT HOLES IS 1 1/2". MINIMUM VERTICAL EDGE DISTANCE TO THE CENTER OF BOLT HOLES IS 1-1/4".
2. FOR SHEAR TAB CONNECTIONS WHT SUPPORTING MEMBER WEB THICKNESS GREATER THAN 3/4" US 3/8" WELD AND 7/16" PL.
3. SINGLE ANGLE CONNECTION USED ONLY WHEN NOTED ON PLAN.
BEAM/BEAM
1/
4"
CL BEAM/GRID
REF BEAM CONNECTION
SCHEDULE FOR BOLT SIZE &
QUANTITY OF ROWS
1 1/2"
STEEL BEAM
(REF PLAN)
1/2"
1 1/2" t t
REF SCHED
1 1/2" 1 1/2"
CL BEAM/GRID
REF BEAM CONNECTION
SCHEDULE FOR BOLT SIZE &
QUANTITY OF ROWS
STEEL BEAM
(REF PLAN)1/2"
t t
REF SCHED
SINGLE PLATE
BEAM CONNECTION SCHEDULE
BEAM
SIZE
PLATE
SIZE
WELD
SIZE
ROWS OF
3/4"Ø A325-N
BOLTS
REMARKS
W8, W10 PL 1/4"X3 1/2"X5 1/2" 3/16" ---
W12, W14 PL 1/4"X3 1/2"X8 1/2" 3/16" ---
W16 PL 5/16"X3 1/2"X11 1/2" 1/4" ---
W18 PL 5/16"X3 1/2"X1'-2 1/2" 1/4" ---
W21 PL 5/16"X3 1/2"X1'-5 1/2" 1/4" ---
W24, W27 PL 5/16"X3 1/2"X1'-8 1/2" 1/4" ---
W30 PL 5/16"X3 1/2"X1'-11 1/2" 1/4" ---
W33 PL 3/8"X3 1/2"X2'-2 1/2" 1/4" ---
STRUCT COL
(REF PLAN)3"
S
PA
1/
4" 1 1/
4"3" S
PA
1/
4"
OUTSIDE DEEP
LEG 18GA TOP
TRACK, TYP
STEEL JOIST
(REF PLAN)
STEEL STUD WALL
STEEL DECK (REF PLAN)
INSIDE DEEP LEG 18 GA TOP
TRACK - SNUG TIGHT ONLY -
NO CONNECTION OF DEEP
LEG TRACK TO TOP TRACK
STEEL DECK (REF PLAN)
STEEL JOIST
(REF PLAN)
INSIDE DEEP LEG 18 GA TOP
TRACK - SNUG TIGHT ONLY - NO
CONNECTION OF DEEP LEG
TRACK TO TOP TRACK
OUTSIDE DEEP
LEG 18 GA TOP
TRACK, TYP
STEEL STUD WALL
MIN
8"
AT ONE END ONLY PROVIDE
SLOTTED HOLES IN BEAM
FLANGE & GREASE SURFACE
BETWEEN BEAM & BRG PLATE
PL 3/8"X6"X6" BRG
(2) 5/8"Ø HAB (5" EMBED)
GROUT & REINF 2 CORES MIN
(REF PLANS / GEN NOTES)
LINTEL BEAM AND
PLATE (REF PLAN) 5"
2'-0"
3" CLR
DRAINAGE COURSE
D
45°
ST
EP
V
AR
IE
S
20K4SP
125 150 275 SP1 = MECH UNIT DL
SPECIAL LOADS
SL TOTALDL
UNIFORM JOIST LOADS (PLF)
SIZE
SPECIAL JOIST LOADING SCHEDULE
P1 P1
P1 = 550 LBS
REF PLAN
UNIT
MECH REF PLAN
SP1
CONC SLAB ON METAL DECK
BEARING PL3/4"X8"X8" W/
(2)3/4"X7" EMBED HAB ATOP
1-1/2" NSNM GROUT
CONTINUE WALL & CONT FTG
REINF THRU PIER- REF EXTERIOR
FOUNDATION DETAIL
TOF
REF PLAN
GRID
GEOTECH APPROVED STIFF SILT SOILS
OR ENGINEERED FILL (REF S-001)
1" 2 1/2"
(3)#4 TIES @3"OC AT TOP
AROUND ANCHORS, THEN #4
TIE @ 12"OC (WRAP TIES
BACK PAST WALL REINF)
(4)#7 VERT/L-BAR
EACH CORNER
1' -1
0" A
PP
RO
X.
3/8" WEB STIFFENERS
EACH SIDE
SLOTTED HOLE
IN BEAM FLANGE
10"
SQ
1'-0"
EXIST FND
WALL
-VERIFY
EXISTING
CRAWLSPACE
TOC/FIRST LEVEL
REF PLAN
GRID
REF PLAN
6" 1'
-0
#5 DOWELS @ 12"OC- DRILL
& EPOXY SET (6" EMBED)
(2)#5X12"X12" DOWELS
TOP &BOT- DRILL &
EPOXY SET (4" EMBED)
#5 @ (4) LOC
SHOWN
EXIST TOF
VERIFY
GEOTECH APPROVED STIFF SILT SOILS
OR ENGINEERED FILL (REF S-001)
CONC SLAB ON METAL DECK
BEARING PL3/4"X8"X8" W/
(2)3/4"X7" EMBED HAB ATOP
1-1/2" NSNM GROUT
(3)#3 TIES @ 3"OC AT TOP
AROUND ANCHORS, THEN
#3 TIE @ 12"OC
(4)#6 VERT/L-BAR
EACH CORNER
3/8" WEB STIFFENERS
EACH SIDE
SLOTTED HOLE
IN BEAM FLANGE 1"2 1/2"
1' -1
0" A
PP
RO
X.
4" 4"
L2x2x3/16"
EA SIDE, TYP
STEEL
JOISTS 1/2"Ø A36 THD
ROD, TYP
UNISTRUT PER
EQUIPMENT SUPPLIER
OR L3X3X1/4"
L2x2x1/4" BRACING EACH END
SUPPLIER'S DRAWINGS
PER EQUIP
SUPPLIER'S DRAWINGS
PER EQUIP
SUPPLIER'S DRAWINGS
PER EQUIP
UNISTRUT PER
EQUIPMENT
SUPPLIER OR
L3X3X1/4"
L3x3x1/4" BRACING, TYP (MATCH THD
ROD SUPPORT SPACING)
1/2" DIA A36
THD ROD AT EACH
ANCHOR LOCATION-
COORDINATE W/
EQUIPMENT
PL1/4"x3" TYP
(VERIFY WIDTH)
L2x2x1/4" BRACING, TYP (MATCH THD
ROD SUPPORT
SPACING)
(4)1/2"Ø A36 THD RODS, TYP
L3x3x1/4" CONT AT EACH
THREADED ROD LINE
3/16"
TYP
LIGHT/EQUIPMENT MOUNT-
COORD LOC & LENGTHS OF
EQUIP SUPPORTS WITH
INSTALLATION REQUIREMENTS
L3X3X1/4" BRACING BACK
TO JOIST PANEL POINTS IN TWO
PERPENDICULAR DIRECTIONS
STEEL
JOISTS
L3x3x1/4" CONT AT EACH
THREADED ROD LINE
LIGHT/EQUIPMENT MOUNT-
COORD LOC & LENGTHS OF
EQUIP SUPPORTS WITH
INSTALLATION REQUIREMENTS
L3X3X1/4" BRACING BACK
TO JOIST PANEL POINTS IN TWO
PERPENDICULAR DIRECTIONS
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NOT
FO
R
CONSTR
UCTI
ON
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
ST
ED
D
R
AW
IN
G
S
SC
AL
E(
S) U
N
LE
SS
R
ED
U
C
ED
F R
O M
O R
IG
IN
AL
x
F
O
RM
AT
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
4/ 7/
1:
:0
A
M I:\
_T S
P R ev it
Lo ca l\0
D ak ot a P la in s
K yl e C lin ic
S
_W ei er sA
R .r vt
SCHEDULES &
DETAILS
S-501
0%
D
ES
IG
N
D O
C U
M
EN
TS
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
ARW04/07/2017
CSH03161153
SCALE: 3/4" = 1'-0"
B5
TYPICAL LINTEL BEARING DETAIL
SCALE: 3/4" = 1'-0"
A3
TYPICAL CORE REINF DETAIL
SCALE: 3/4" = 1'-0"
B4
SCHEDULE - MASONRY LINTEL
SCALE: 3/4" = 1'-0"
A2
TYP UTILITY THRU WALL
SCALE: 3/4" = 1'-0"
A5
TYP BRICK ANGLE BEARING @CONTROL POINT
SCALE: 3/4" = 1'-0"
A4
SCHEDULE - EXT NON-BRG BRICK/CMU ANGLE
SCALE: 1" = 1'-0"
C4
SCHEDULE - BEAM - SINGLE PLATE DESIGN
SCALE: 3/4" = 1'-0"
D2
TYP NON-LOAD BEARING STEEL STUD WALL DETAIL
SCALE: 3/4" = 1'-0"
D1
TYP NON-LOAD BEARING STEEL STUD WALL DETAIL
SCALE: 3/4" = 1'-0"
B3
TYP LINTEL BEARING
SCALE: 3/4" = 1'-0"
A1
TYP FOOTING STEP - CONC WALL
SCALE: 1/4" = 1'-0"
D3
SCHEDULE - SPECIAL JOIST LOADING
SCALE: 3/4" = 1'-0"
B1
CONCRETE PIER/BEAM BRG @ NEW
SCALE: 3/4" = 1'-0"
B2
CONCRETE PIER/BEAM BRG @ EXISTING
SCALE: 3/4" = 1'-0"
C2
TYPICAL LIGHT/EQUIPMENT SUPPORT DETAIL
MARK DATE DESCRIPTION
SHEET GENERAL NOTES:
KEY NOTES:
SHEET GENERAL NOTES:
KEY NOTES:
FIRST LEVEL
100' - 0"
T.O. JOIST BEARING
113' - 4"
T.0. MASONRY
115' - 4"
A2
A-301
W1 W1
E X
IS
T
IN
G
N E
W
3 2 1.7 1
2'-0"
FIRST LEVEL
100' - 0"
T.O. JOIST BEARING
113' - 4"
T.0. MASONRY
115' - 4"
C1
A-301
W1 W2 W2 W2
N E
W
E X
IS
T
IN
G
C B.5 B A.9 A.3 A
7 7
8 8
APPLY SEALANT AND BACKER ROD TO ALL JOINTS BETWEEN DISSIMILAR MATERIALS.A.
ALL SURFACES DAMAGED DURING DEMOLITION SHALL BE REPAIRED FOR APPLICATION OF NEW FINISHES
OR PATCHED TO MATCH EXISTING.
B.
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS WHICH ARE TO MATCH
EXISTING CONSTRUCTION. CONTACT A/E WITH DISCREPANCIES.
C.
EXTERIOR ELEVATIONS
NOTE: NOT ALL KEYNOTES MAY BE USED ON EACH PLAN
EXTERIOR ELEVATIONS
1 FACE BRICK
2 BRICK SOLDIER COURSE
3 GLAZED BLOCK DECORATIVE BAND LAYOUT - MATCH EXISTING PATTERN
4 PRE-FINISHED METAL COPING
5 EARTH BERM TO MATCH EXISTING ADJACENT.
6 CONCRETE RETAINING WALL. REFERENCE CIVIL DRAWINGS
7 NEW BRICK LEDGE MATCH EXISTING.
8 MASONRY EXPANSION JOINT.
1/4" / 12"
1/4" / 12"
/4
/4
RD
OD
+4
+9.25"
+9.25"
+9.25"
+7.25"
+9.25"
A2
A-301
A1
A-301
A3
A-301
D5
A-501
D5
A-501
1/4" / 12"
MODIFICATIONS TO EXISTING ROOF TO BE DONE BY CERTIFIED INSTALLER TO AVOID WARRANTY ISSUES.C.
ALL SURFACES DAMAGED DURING DEMOLITION SHALL BE REPAIRED FOR APPLICATION OF NEW FINISHES
OR PATCHED TO MATCH EXISTING.
A.
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS WHICH ARE TO MATCH
EXISTING CONSTRUCTION. CONTACT A/E WITH DISCREPANCIES.
B.
MINIMUM INSULATION THICKNESS OF 4" AT ROOF DRAINS.D.
ROOF PLAN
SEAL ALL PENETRATIONS AT ROOF MEMBRANE PER MANUFACTURER'S STANDARDS TO MAINTAIN ROOF
WARRANTY.
E.
OS
OVERFLOW SCUPPER
RD ROOF DRAIN
OD OVERFLOW ROOF DRAIN
REVISION TAG
KEYNOTE TAG
SECTION TAG
DETAIL TAG
ROOF PLAN LEGEND
A-101
A1
SIM
EPDM WALKMATS -
PROVIDE AROUND MECHANICAL EQUIPMENT
AND AS SHOWN
VTR VENT THROUGH ROOF - REF PLUMBING
REV
A1
A-301
3"
APPROXIMATE ROOF INSULATION
THICKNESS
NOTE: NOT ALL KEYNOTES MAY BE USED ON EACH PLAN
ROOF PLAN
1 EXISTING ROOFING TO REMAIN.
2 NEW PREFINISHED METAL COPING OVER EXISTING PARAPET AND NEW ROOF MEMBRANE.
PROVIDE ADEQUATE OVERLAP BETWEEN NEW AND EXISTING ROOF MEMBRANE TO MAINTAIN
ROOFING WARRANTY.
3 OVERLAP AND SEAL NEW COPING WITH EXISTING COPING TO PROVIDE A WETHERTIGHT SEAL.
4 PROTECTIVE SECONDARY WEAR/WALKING MEMBRANE. 30" WIDE TYPICAL.
5 MECHANICAL ROOF TOP UNIT. REFERENCE MECHANICAL DRAWINGS.
6 MECHANICAL ROOF VENT. REFERENCE MECHANICAL DRAWINGS.
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
N O T
FO
R
C O N S
TR
U C
TI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/7
/2
:3
:0
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic A jo h n s o n d p
.r v t
EXTERIOR
ELEVATIONS & ROOF
PLAN
A-201
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
AJP04/07/2017
DPJ03161153
SCALE: 1/8" = 1'-0"
D1
NORTH ELEVATION
SCALE: 1/8" = 1'-0"
C1
WEST ELEVATION
SCALE: 1/16" = 1'-0"
A1
ROOF PLAN
D
TH
TS
T
SW
S
CO2
CO
NO2
HS
H
M C
F
FS B
(E)
16"x8"
16"/8"
16"Ø
2"
4" RD-1
PLUG
2"
4"
4" 4"
PLUMBING AND PIPING SYMBOLS
GRILLES, REGISTERS, AND DIFFUSERS TAG
CFM
KEYNOTE
CONTINUATION SYMBOL
OVAL DUCT SIZE TAG (WIDTH / HEIGHT)
SQUARE DUCT SIZE TAG (WIDTH x HEIGHT)
NUMBER OF SHEET WHERE DETAIL APPEARS
NUMBER OF DETAIL ON SHEET
REVISION NUMBER - SHOWN ON PLANS
GENERAL MECHANICAL SYMBOLS
ROOM NAME AND NUMBER
POINT WHERE NEW CONNECTS TO EXISTING
HVAC SYMBOLS
MECHANICAL EQUIPMENT TAG
EXISTING MECHANICAL EQUIPMENT TAG
(TYPICAL FOR ALL EXISTING TAGS)
& AND
Ø ROUND
A AIR
AB ABOVE BASE
ABV ABOVE
AC AIR CONDITIONING
ACOUS ACOUSTICAL
AD AREA DRAIN
ADD ADDENDUM
ADDL ADDITIONAL
AFF ABOVE FINISHED FLOOR
AFUE ANNUAL FUEL UTILIZATION EFFICIENCY
AG ABOVE GROUND
ALT ALTERNATE
ALUM ALUMINUM
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT/ARCHITECTURAL
AV ACID RESISTANT VENT
AW ACID RESISTANT WASTE
AUTO AUTOMATIC
BFF BELOW FINISHED FLOOR
BLDG BUILDING
BLW BELOW
BM BEAM
BO BY OTHER
BOT BOTTOM
BSMT BASEMENT
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER HOUR
BTWN BETWEEN
CAP CAPACITY
CB CATCH BASIN
CCW COUNTER CLOCKWISE
CFCV CONSTANT FLOW CONTROL VALVE
CFM CUBIC FEET PER MINUTE
CHW CIRCULATING HOT WATER
CI CAST IRON
CLG CEILING
CLG COOLING
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
COND CONDENSATE
CONF CONFERENCE
CONN CONNECT
CONST CONSTRUCTION
CONT CONTINUE/CONTINUATION
CONTR CONTRACT/CONTRACTOR
COORD COORDINATE
CTR CENTER
CUFT CUBIC FEET
CV CHECK VALVE
CW COLD WATER
CW CLOCKWISE
D DEGREE
DB DRY BULB
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DISCH DISCHARGE
DIV DIVISION
DI DEIONIZED WATER
DMPR DAMPER
DN DOWN
DWG DRAWING
DW DISTILLED WATER
EA EACH
EAT ENTERING AIR TEMPERATURE
EL ELBOW
ELEC ELECTRICAL
ELEV ELEVATION
EP EXPLOSION PROOF
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
E/A EXHAUST AIR
EAH EXHAUST HOOD
EXIST EXISTING
EXP EXPANSION
EXPJT EXPANSION JOINT
EXT EXTERIOR
F DEGREES FAHRENHEIT
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FD FIRE DAMPER
FDV FIRE DEPARTMENT VALVE
FHC FIRE HOSE CABINET
FL FLOOR
FLEX FLEXIBLE
FLG FLANGE
FO FUEL OIL
FOV FUEL OIL VENT
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FPM FEET PER MINUTE
FRP FIBERGLASS REINFORCED PIPE
FS FULL SIZE
FS FLOOR SINK
FT FOOT/FEET
FTG FOOTING
FTR FIN TUBE RADIATION
FUT FUTURE
GA GAGE/GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GENL GENERAL
GPH GALLONS PER MINUTE
GR GRADE
GW GREASE WASTE
HB HOSE BIB
HD HEAD
HORZ HORIZONTAL
HP HORSE POWER
HP HIGH PRESSURE
HTG HEATING
HTR HEATER
HW HOT WATER
HYD HYDRANT
ID INDIRECT
IN INCH
INL INLET
INSUL INSULATION
INT INTERIOR
INV INVERT
INWG INCHES WATER GAUGE
JST SPC JOIST SPACE
JT JOINT
LAB LABORATORY
LB POUND
LB/HR POUNDS PER HOUR
LAT LEAVING AIR TEMPERATURE
LF LINEAL FOOT
LOC LOCATION
LP LOW PRESSURE
LPG LIQUEFIED PETROLEUM GAS
LR LIQUID REFRIGERANT
LS LAWN SPRINKLER
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M/A MIXED AIR
MAN MANUAL
MATL MATERIAL
MAV MANUAL AIR VENT
MAX MAXIMUM
MBD MOTORIZED BYPASS DAMPER
MBH ONE THOUSAND BTU PER HOUR
MCF ONE THOUSAND CUBIC FEET
MCW MAKE-UP COLD WATER
MD MOTORIZED DAMPER
MECH MECHANICAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MTR MOTOR
MU/A MAKE-UP/AIR
N NECK
NC NOISE CRITERIA
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NUMBER
NO NORMALLY OPEN
NOM NOMINAL
NTS NOT TO SCALE
O OXYGEN
O/A OUTSIDE AIR
OC ON CENTER
OF OVERFLOW
OPNG OPENING
ORD OVERFLOW ROOF DRAIN
PD PRESSURE DROP
PIV POST INDICATOR VALVE
PLBG PLUMBING
PR PAIR
PREL PRELIMINARY
PRESS PRESSURE
PRIM PRIMARY
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PW POTABLE WATER
PWR POWER
R DUCT RISER
R/A RETURN AIR
RCP RADIANT CEILING PANEL
RD ROOF DRAIN
REC RECESSED
RED REDUCER
REFR REFRIGERATION
RH RELATIVE HUMIDITY
REQD REQUIRED
REV REVERSE
RL/A RELIEF AIR
RM ROOM
RPM REVOLUTIONS PER MINUTE
RW RAIN WATER
SF SQUARE FOOT
S/A SUPPLY AIR
SAN SANITARY
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SD SMOKE DAMPER
SHT SHEET
SIM SIMILAR
SLV SLEEVE
SM SURFACE MOUNT
SP STANDPIPE
SP STATIC PRESSURE
SPEC SPECIFICATION
SPS STATIC PRESSURE STATION
SQ SQUARE
SR SUCTION REFRIGERANT
SSD SOIL SUBDRAIN
SS STAINLESS STEEL
STD STANDARD
STM STEAM
STRUCT STRUCTURAL
SUCT SUCTION
SUSP SUSPENDED
T THERMOSTAT
TCP TEMPERATURE CONTROL PANEL
TD TEMPERATURE DROP
TDR TRENCH DRAIN
TEFC TOTALLY ENCLOSED FAN COOLED
TEMP TEMPERATURE
TYP TYPICAL
UFD UNDER FLOOR DUCT
UG UNDERGROUND
VAC VACUUM
V VENT
VAV VARIABLE AIR VOLUME
VEL VELOCITY
VENT VENTILATION
VERT VERTICAL
VOL VOLUME
VTR VENT THROUGH ROOF
W WASTE
WB WET BULB
WCO WALL CLEAN OUT
WH WALL HYDRANT
ABBREVIATIONS
FIRE DAMPER
SMOKE DAMPER
MOTORIZED DAMPER
MANUAL BALANCING DAMPER
BACKDRAFT DAMPER
COMBINATION FIRE/SMOKE DAMPER
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
HUMIDISTAT
HUMIDITY SENSOR
NITROGEN DIOXIDE SENSOR
SENSOR
TEMPERATURE & HUMIDITY SENSOR
SUPPLY OUTLET
RETURN / EXHAUST INLET
LINEAR DIFFUSER
RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISE
RECTANGULAR RETURN/TRANSFER AIR DUCT RISE
MECHANICAL EQUIPMENT
ROUND DUCT SIZE TAG (DIAMETER)
EXISTING PIPE TAG
DOMESTIC
WATER METER
AC AIR CONDITIONING UNIT
ACC AIR COOLED CONDENSER
ACCU AIR COOLING CONDENSING UNIT
AFMS AIR FLOW MEASURING STATION
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
B BOILER
CF CABINET FAN
CF CHEMICAL FEEDER
CFP CHEMICAL FEEDER PUMP
CH CHILLER
CRU CONDENSATE RETURN UNIT
CT COOLING TOWER
CUH CABINET UNIT HEATER
CWP CONDENSER WATER PUMP
CHWP CHILLED WATER PUMP
DBP DOMESTIC WATER BOOSTER PUMP
DC DUCT MOUNTED COIL
DCP DOMESTIC WATER CIRCULATING PUMP
EF EXHAUST FAN
EDC ELECTRIC DUCT COIL
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
FCU FAN COIL UNIT
FP FIRE PUMP
GI GREASE INTERCEPTOR
GRV GRAVITY ROOF VENTILATOR
H HUMIDIFIER
HWP HEATING WATER PUMP
HX HEAT EXCHANGER
HPU HEAT PUMP UNIT
HRU HEAT RECOVERY UNIT
ILC INLINE CENTRIFUGAL
PF PROPELLER FAN
PRV POWER ROOF VENTILATOR
PWF POWER WALL FAN
RE RETURN/EXHAUST FAN
RTU ROOFTOP UNIT
SA SHOCK ABSORBER
SAT SOUND ATTENUATOR
SEP SEWAGE EJECTOR PUMP
SF SUPPLY FAN
SP SUMP PUMP
UH UNIT HEATER
US UTILITY SET
UV UNIT VENTILATOR
WFMS WATER FLOW MEASURING STATION
WH WATER HEATER
EQUIPMENT ABBREVIATIONS
PIPING BEING DEMOLISHED
THERMOSTAT
TEMPERATURE SENSOR
MANUAL SWITCH
TYPE (SEE SCHEDULE)
ROUND SUPPLY/OUTSIDE AIR DUCT RISE
ROUND RETURN/TRANSFER AIR DUCT RISE
RECTANGULAR EXHAUST/RELIEF AIR DUCT RISE
ROUND EXHAUST/RELIEF AIR DUCT RISE
ABOVE GROUND PIPING
PIPE SIZE TAG (DIAMETER)
DROP
DROP
DROP
DROP
DROP
DROP
EXISTING MECHANICAL EQUIPMENT
FLOOR
CLEAN OUT
DRAIN SIZE
ROOF DRAIN FIXTURE
TYPE (SEE SCHEDULE)
DRAIN TAG
PLUMBING FIXTURE TAG
PLUMBING FIXTURE
REDUCING 45 DEGREE TEE
45 DEGREE TEE
Room
BELOW GROUND PIPING
PIPE INVERT ELEVATION TAG
PIPE SLOPE TAG
INV. ELEV:-5' - 1"
1/8" / 12" SLOPE
* NOTE *
ALL OF GENERAL NOTES ON THIS SHEET ARE TO BE APPLIED TO ALL OTHER DRAWINGS IN THIS
SET.THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE USED IN
THIS SET OF DRAWINGS.
MECHANICAL EQUIPMENT TAG
(REFER TO OTHER DISCIPLINE FOR ADDITIONAL
INFORMATION)
MECHANICAL EQUIPMENT FOR REFERENCE
4" OFD-1
WH-1
TYPE (SEE SCHEDULE)
S-3
FP-D
FP-O
FP-PA
FP
FIRE PROTECTION PRE-ACTION
FIRE PROTECTION WET
FIRE PROTECTION OTHER
FIRE PROTECTION DRY
FIRE PROTECTION SYMBOLS
UPRIGHT SPRINKLER HEAD
PENDENT SPRINKLER HEAD
RECESSED SPRINKLER HEAD
CONCEALED SPRINKLER HEAD
'D' REPRESENTS DRY SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
EXTENDED COVERAGE
SIDEWALL SPRINKLER HEAD
FP-DOM-W COMBINATION FIRE & DOMESTIC
OBSTRUCTION FROM
DUCTWORK 48" AND GREATER
48"x18" S/A
V
W
ORDB
ORD
SANITARY VENT
SANITARY WASTE
STORM DRAINAGE OVERFLOW BELOW
STORM DRAINAGE OVERFLOW
RD STORM DRAINAGE
ORDB STORM DRAINAGE OVERFLOW BELOW
SANITARY WASTE-BELOW
NO
O
MEDICAL NITROUS OXIDE
MEDICAL OXYGEN
MV MEDICAL VACUUM
N MEDICAL NITROGEN
MGAS
H
MEDICAL GAS
MEDICAL HYDROGEN
CO2 MEDICAL CO2
LV
MA
LAB VACUUM
MEDICAL AIR
LDE
LDI
LAB DEIONIZED WATER
LAB DISTILLED WATER
LA LAB AIR
LG LAB GAS
LAB AND MEDICAL SYMBOLS
CWS
CWR CHILLED WATER RETURN
CHILLED WATER SUPPLY
AW
AWB
AV ACID VENT
ACID WASTE
ACID WASTE BELOW
CR
CS
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
A
CD
CDR
COMPRESSED AIR
CONDENSATE DRAINAGE
CONDENSATE RETURN
CWV COMBINATION WASTE & VENT
DE
DI
DEIONIZED WATER
DISTILLED WATER
CW
F-CW
HCW
SCW
TW
HW 140°
RHW
RHW 140°
DOMESTIC COLD WATER
DOMESTIC COLD WATER-FILTERED
DOMESTIC COLD WATER-HARD
DOMESTIC COLD WATER-SOFT
DOMESTIC TEMPERED WATER
DOMESTIC HOT WATER 140°
DOMESTIC HOT WATER RECIRCULATING
DOMESTIC HOT WATER RECIRCULATING 140°
G-2LB NATURAL GAS 2LB
DUAL TEMP WATER RETURN
DUAL TEMP WATER SUPPLY
GEOTHERMAL RETURN
GEOTHERMAL SUPPLY
GLYCOL HOT WATER RETURN
GLYCOL HOT WATER SUPPLY
GREASE VENT
GREASE WASTE
DTWR
DTWS
GTR
GTS
GHR
GHS
GV
GW
HWR
HWS
HEATING WATER RETURN
HEATING WATER SUPPLY
G NATURAL GAS
MIT MITIGATION VENT
PRO PROPANE GAS
OV
OW
OIL VENT
OIL WASTE
HPS STEAM - HP
RL
RS
REFRIGERANT LIQUID
REFRIGERANT SUCTION
RHG REFRIGERANT HOT GAS
REF REFRIGERANT
PD PUMP DISCHARGE
HPR STEAM - HP CONDENSATE
MPS STEAM - MP
MPR STEAM - MP CONDENSATE
LPS STEAM - LP
LPR STEAM - LP CONDENSATE
1. SIDE CONNECTION
2. ELBOW DOWN
3. ELBOW UP
4. SHUT OFF VALVE
5. BALANCING VALVE
6. CONTROL VALVE
7. PRESSURE REDUCING VALVE
8. PRESSURE RELIEF VALVE
9. CHECK VALVE
10. AIR VENT
11. PRESSURE GAUGE
12. THERMOMETER
13. PIPE ANCHOR
14. PIPE GUIDE
15. CONCENTRIC REDUCER
16. ECCENTRICL REDUCER
17. STRAINER
18. UNION
19. DIRECTION OF FLOW
20. PITCH PIPE DOWN
21. 3-WAY CONTROL VALVE
22. PUMP
23. FLOW SWITCH
24. PRESSURE TEMPERATURE TAP
25. MANUAL CALIBRATED BALANCING VALVE
26. AUTOMATIC FLOW CONTROL VALVE
27. MEDICAL GAS OUTLET
28. HOSE-BIBB OR WALL HYDRANT
29. INSERTION FLOW METER
30. FLOW METER
31. REDUCED PRESSURE BACKFLOW PREVENTER
32. AQUASTAT
33. 3-WAY VALVE
END CAP
1 2 3 4 5 6 7 98
11 1210 13 14 15 16 17 18
20 21 22 25
FS
23 24 26 27 28
FM
A
3230 31
FCO
GAS METERFLOOR
DRAIN
WALL
CLEAN OUT
WCO
PIPE BREAK
DOWNSPOUT NOZZLE
FLEX DUCT
XXX-X
(E)XXX-X
XXX-X
WB
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NO
T
FO
R
CO
NSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/7
/2
:5
:5
A
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic M m a k s c h .r v t
MECHANICAL TITLE
SHEET
M-001
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
CHM04/07/2017
SMT03161153
FIRE PROTECTION GENERAL NOTES
* EXST 1 PROVIDE ALTERATIONS TO THE EXISTING FIRE SUPPRESSION SYSTEM AS REQUIRED TO
ACCOMMODATE THE NEW FLOOR PLAN AND NEW CEILING TYPES. PROVIDE A COMPLETE WET
TYPE SYSTEM INCLUDING NEW MAINS, BRANCHES, HEADS, VALVES, AND ACCESSORIES AS
REQUIRED. REUSE EXISTING SYSTEM EQUIPMENT WHERE APPLICABLE. THE SYSTEM SHALL BE
INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS AND
AS PER REQUIREMENTS OF THE STATE BUILDING CODE, LOCAL FIRE DEPARTMENT, AND ALL
FEDERAL, STATE, AND LOCAL AUTHORITIES, NFPA, AND FACTORY MUTUAL.
* EXST 2 THE BUILDINGS COMPLETE OPERATIONAL FIRE SUPPRESSION SYSTEMS SHALL REMAIN IN
PLACE. THIS CONTRACTOR SHALL REPAIR ANY DAMAGE TO THIS SYSTEM CREATED BY THE
REMOVAL OF ANY OTHER MECHANICAL SYSTEMS OR COMPONENTS.
* EXST 3 THIS CONTRACTOR SHALL COORDINATE PHASING OF WORK WITH THE GENERAL CONTRACTOR
PRIOR TO STARTING WORK.
* NEW 1 PROVIDE A COMPLETE WET TYPE FIRE SUPPRESSION SYSTEM AS REQUIRED TO
ACCOMMODATE THE FLOOR PLAN AND CEILING TYPES INCLUDING MAINS, BRANCHES, HEADS,
VALVES, AND ACCESSORIES AS REQUIRED. THE SYSTEM SHALL BE INSTALLED ACCORDING TO
MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS OF THE STATE BUILDING CODE,
LOCAL FIRE DEPARTMENT, AND ALL FEDERAL, STATE, AND LOCAL AUTHORITIES, NFPA, AND
FACTORY MUTUAL.
* NEW 2 THE FIRE SUPPRESSION SYSTEM SHALL BE DESIGNED BASED UPON ACTUAL WATER FLOW
TEST DATA OBTAINED AT OR NEAR THE JOB SITE.
* NEW 3 REFER TO REFLECTED CEILING PLANS FOR ADDITIONAL INFORMATION REGARDING SPRINKLER
LOCATION AND PIPE, UNLESS NOTED OTHERWISE.
* NEW 4 DIVISION 21 CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR
PROPER INSTALLATION OF THE FIRE SUPPRESSION SYSTEMS ALARM DEVICES INVOLVED WITH
FIRE SPRINKLER SYSTEM.
* NEW 5 ALL FIRE SUPPRESSION SYSTEM PIPING SHALL BE CONCEALED ABOVE THE SUSPENDED
CEILING SYSTEM, UNLESS NOTED OTHERWISE. WRITTEN AUTHORIZATION SHALL BE OBTAINED
FROM THE ARCHITECT PRIOR TO EXPOSING ANY PIPING IN ANY ROOM WHICH HAS A
SUSPENDED CEILING.
* NEW 6 AUXILIARY DRAINS SHALL BE EXPOSED WITH 1" DRAIN VALVES. WHEN 5 OR MORE GALLONS
ARE TRAPPED, THIS CONTRACTOR SHALL PROVIDE FIXED PIPING TO AN ADEQUATELY SIZED
RECEPTOR WHICH IS CAPABLE OF ACCEPTING THE FULL FLOW OF THE DRAIN. WHEN LESS
THAN 5 GALLONS ARE TRAPPED, A HOSE BIB SHALL BE PROVIDED AT THE DRAIN VALVE.
* NEW 7 AUXILIARY DRAINS SHALL NOT BE LOCATED ABOVE PLASTER OR GYPSUM BOARD CEILING
SYSTEMS.
* NEW 8 AN INSPECTOR'S TEST CONNECTION SHALL BE PROVIDED FOR EACH FIRE SUPPRESSION ZONE.
THIS CONTRACTOR SHALL PROVIDE FIXED PIPING FROM THE TEST CONNECTION TO AN
ADEQUATELY SIZED RECEPTOR WHICH IS CAPABLE OF ACCEPTING THE FULL FLOW OF THE
TEST. EXTERIOR DISCHARGE OF THE TEST CONNECTION SHALL BE PERMITTED ONLY BY
SPECIFIC WRITTEN INSTRUCTION FROM THE ENGINEER.
* NEW 9 SHOW ALL ROOM NAMES & NUMBERS ON SHOP DRAWING PLANS.
* NEW 10 THE CONTRACTOR SHALL PERFORM A FIRE FLOW TEST IN ACCORDANCE WITH NFPA 291.
* NEW 11 ROUTE PIPING SUCH THAT IT DOES NOT RUN ABOVE ELECTRICAL PANELS, SWITCHGEAR, OR
SIMILAR EQUIPMENT. MAINS SHALL NOT RUN THROUGH ELECTRICAL OR COMMUNICATION
ROOMS. SPRINKLERS IN THESE ROOMS SHALL BE SERVED BY A DEDICATED BRANCH LINE FOR
EACH ROOM.
* NEW 12 THIS DRAWING INDICATES A GENERAL PIPING ARRANGEMENT AND SUGGESTED SIZING ONLY.
THIS CONTRACTOR SHALL DETERMINE THE PIPE ROUTING AND SIZING REQUIRED AND
COORDINATE WORK WITH ALL OTHER TRADES TO AVOID CONFLICTS.
* NEW 13 THIS CONTRACTOR SHALL PREPARE HYDRAULIC CALCULATIONS BASED UPON THE
CONFIGURATION OF THE ACTUAL SYSTEM DESIGN AS SHOWN ON THIS CONTRACTOR'S SHOP
DRAWINGS.
* NEW 14 FIRE STOPPING & SEALING: ALL PIPE AND DUCT WHICH PENETRATE RATED WALLS AND OR
CEILING ASSEMBLIES SHALL BE PROPERLY FIRE STOPPED AND SEALED AS REQUIRED BY THE
LOCAL BUILDING CODE AUTHORITIES. SEE DETAILS.
* NEW 15 THE FIRE SUPPRESSION CONTRACTOR SHALL SUBMIT DETAILED WORKING PLANS SHOWING
PROPER SPRINKLER PLACEMENT, HYDRAULIC CALCULATIONS AND PIPE SIZE FOR THIS
PROJECT PRIOR TO COMMENCING INSTALLATION.
* NEW 16 FIRE SUPPRESSION CONTRACTOR SHALL VERIFY ALL EXISTING FIRE SUPPRESSION PIPING AND
SPRINKLERS WITH RESPECT TO ALL NEW MECHANICAL EQUIMENT LOCATION. IF THERE IS ANY
INTERFERENCE NOTED, THE FIRE SUPPRESSION CONTRACTOR SHALL BE RESPONSIBLE TO
RELOCATE EXISTING PIPING AND SPRINKLERS TO MEET REQUIREMENTS.
* NEW 17 SPRINKLER AND PIPING INSTALLATION SHALL BE COORDINATED CAREFULLY WIHT NEW AND
EXISTING LIGHTS, GRILLES, SPREAKERS, ETC., TO AVOID CONFLICTS.
* NEW 18 CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND REINSTALLATION OF EXISTING
CEILINGS REQUIRED TO INSTALL PIPING (UNLESS NOTED OTHERWISE).
HVAC GENERAL NOTES
* NEW 1 SUPPLY AND RETURN PIPING TO COILS ARE THE SAME SIZE.
* NEW 2 CONTRACTOR SHALL LOCATE THERMOSTATS AND TEMPERATURE SENSORS AT 4'-0" AFF, A
MINIMUM OF 8" FROM LIGHT SWITCH.
* NEW 3 REFER TO PIPING DRAWINGS FOR THERMOSTAT AND TEMPERATURE SENSOR LOCATIONS.
* NEW 4 CONDENSATE DRAINS SHALL BE SUPPLIED FOR ALL COOLING EQUIPMENT. CONTRACTOR
SHALL ENSURE PROPER INSTALLATION AND DRAINAGE AS REQUIRED BY FEDERAL, STATE,
AND LOCAL CODES. CONDENSATE PIPING SHALL BE TYPE "L" COPPER.
* NEW 5 PROVIDE A 4" HOUSEKEEPING PAD FOR EACH PIECE OF MECHANICAL EQUIPMENT.
COORDINATE SIZES WITH MECHANICAL EQUIPMENT SELECTED.
* NEW 6 THIS CONTRACTOR SHALL BE REQUIRED TO REPLACE FILTERS ON HVAC EQUIPMENT AFTER
ALL DUST PRODUCING CONSTRUCTION HAS BEEN COMPLETED AND PRIOR TO THE FINAL
PUNCH.
PLUMBING GENERAL NOTES
* EXST 1 FIELD VERIFY ALL NEW WATER, WASTE, AND VENT PIPING CONNECTIONS AND
PROVIDE NEW CONNECTIONS AS REQUIRED FOR PROPERLY OPERATING
SYSTEMS.
* NEW 1 PITCH UNDERFLOOR SANITARY WASTE AND STORM PIPING 3" AND GREATER AT
1/8" PER FOOT, UNLESS NOTED OTHERWISE. PITCH ALL OTHER WASTE PIPING AT
1/4" PER FOOT UNLESS OTHERWISE NOTED.
* NEW 2 FIELD VERIFY LOCATION AND INVERTS OF SITE UTILITIES PRIOR TO
INSTALLATION.
* NEW 3 ROUTE DOMESTIC WATER, FIRE PROTECTION, SANITARY SEWER, AND STORM
SEWER SERVICES TO SITE UTILITIES 5'-0" FROM BUILDING UNLESS NOTED
OTHERWISE. REFER TO CIVIL PLANS.
* NEW 4 WASTE AND VENT PIPING BELOW FLOOR AND THROUGH FLOOR SHALL BE 2"
MINIMUM.
* NEW 5 PROVIDE CLEANOUT IN ACCESSIBLE LOCATION AT THE BASE OF ALL PLUMBING
RISERS.
PROJECT GENERAL NOTES
* DEMO 1 WHERE EQUIPMENT AND/OR FIXTURES ARE INDICATED TO BE REMOVED, THE
EXISTING SERVICES SHALL BE CAPPED AND CONCEALED BEHIND FINISHED
SURFACES. ABANDONED BRANCH SERVICES SHALL BE REMOVED BACK TO THE
MAINS AND CAPPED, UNLESS OTHERWISE INDICATED.
* DEMO 2 CAP ANY ABANDONED OR UNUSED PIPE AND/OR DUCT OPENINGS.
* DEMO 3 THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND PAINTING TO
MATCH EXISTING WALLS, FLOORS, AND CEILINGS.
* DMEO 4 HYDRONIC AND DOMESTIC PIPING SHALL BE THOROUGHLY CLEANED BEFORE
PUTTING INTO PERMANENT SERVICE.
* EXST 1 REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES.
* EXST 2 THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING,
PRIOR TO FINAL BID, ALL EXISTING CONDITIONS FOR PLUMBING AND
MECHANICAL SYSTEMS WITHIN TENANT SPACE AND WITHIN CLOSE PROXIMITY
OF TENANT SPACE.
* EXST 3 THE MECHANICAL CONTRACTOR SHALL PERFORM SERVICE AND REPAIR ON THE
EXISTING EQUIPMENT AND ITS ACCESSORIES AS FOLLOWS: CLEAN ALL COILS,
REPLACE THE FILTERS AND BELTS, INSPECT, REPAIR, OR REPLACE THE
ECONOMIZERS, DRIVES AND FAN BEARINGS, MOTORS, CONTROL COMPONENTS,
VALVES AND ANY OTHER ITEM NECESSARY FOR A COMPLETE AND PROPER
OPERATING SYSTEM. THIS CONTRACTOR SHALL ALSO VISIT THE SITE, PRIOR TO
FINAL BIDDING, AND VERIFY ALL EXISTING SITE CONDITIONS. PROVIDE ALL
MATERIAL AND COMPONENTS AS NEEDED TO BRING THE UNITS TO FULL
COMPLIANCE OF THE LANDLORD'S CRITERIA AND LOCAL AUTHORITY HAVING
JURISDICTION.
* EXST 4 WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF CONSTRUCTION,
PREVENT CONSTRUCTION DEBRIS FROM ENTERING DRAIN BODY BY SEALING
DRAIN OPENING PRIOR TO START OF WORK.
* NEW 1 COORDINATE AND COOPERATE WITH THE OTHER TRADES ON THE
INSTALLATION OF PIPING, DUCTWORK, CONDUIT, LIGHTS, CABLE TRAY,
STRUCTURE, AND EQUIPMENT TO PREVENT CONFLICTS.
* NEW 2 THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE CONDITIONS BOTH
EXISTING AND THOSE ILLUSTRATED BY THESE DOCUMENTS AS WELL AS THOSE
WHICH CAN BE REASONABLY ANTICIPATED INCLUDING, BUT NOT LIMITED TO
ARCHITECTURAL, ELECTRICAL, VENTILATION, PLUMBING, AND OTHER SYSTEMS
INVOLVED ON THIS PROJECT.
* NEW 3 FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING SYSTEM, AND SHALL
CONFORM TO ALL REQUIREMENTS OF APPLICABLE FEDERAL, STATE, AND LOCAL
CODES, INCLUDING BUT NOT LIMITED TO THE INTERNATIONAL BUILDING CODE
AND INTERNATIONAL MECHANICAL CODE.
* NEW 4 LOCATE EQUIPMENT REQUIRING ACCESS 2'-0" MAXIMUM ABOVE CEILING.
* NEW 5 ALL ROOF MOUNTED EQUIPMENT SHALL BE A MINIMUM 10'-0" FROM EDGE OF
ROOF.
* NEW 6 LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT AWAY FROM THE
SPACE ABOVE ELECTRICAL PANELS. TRANSFORMERS AND OTHER ELECTRICAL
EQUIPMENT.
* NEW 7 ADJUST PIPING AND DUCTWORK SIZES TO PROPERLY CONNECT TO
MECHANICAL EQUIPMENT.
* NEW 8 REFER TO PLUMBING SERIES DRAWINGS FOR GAS AND A.C. CONDENSATE
DRAIN PIPING.
* NEW 9 PIPE SIZES SHOWN SHALL BE CONTINUED IN THE DIRECTION OF FLOW UNTIL
ANOTHER SIZE IS SHOWN.
* NEW 10 FOR DETAILS, EQUIPMENT CONNECTIONS, AND PIPE SIZES NOT SHOWN ON THE
SEGMENTS, REFER TO DETAILS, SCHEDULES, AND SPECIFICATIONS.
* NEW 11 INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE RESPECTIVE
MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS.
* NEW 12 LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS INDICATED ON THE
DRAWING, ARE APPROXIMATE AND SUBJECT TO MINOR ADJUSTMENTS IN THE
FIELD. WORK SHALL BE COORDINATED WITH ALL OTHER TRADES TO AVOID
INTERFERENCE IN THE FIELD.
* NEW 13 INSTALL EXPOSED PIPING AND DUCTWORK AS HIGH AS PRACTICAL IN ROOMS
WITHOUT CEILINGS.
* NEW 14 MATERIALS AND EQUIPMENT SHOWN ON PLANS SHALL BE NEW AND FURNISHED
BY THIS CONTRACTOR UNLESS OTHERWISE INDICATED.
* NEW 15 THIS CONTRACTOR IS RESPONSIBLE FOR ALL SLEEVES AND/OR OPENINGS
WHERE REQUIRED TO RUN PIPES AND DUCTS THROUGH FOUNDATIONS,FLOOR
SLABS, WALLS, BRIDGING AND BEAMS EXCEPT WHERE OTHERWISE INDICATED.
* NEW 16 CEILING ACCESS IS REQUIRED AT ALL REHEAT COILS, VALVES, FIRE DAMPERS,
MANUAL AND MOTORIZED DAMPERS LOCATED ABOVE CEILING. CEILING
ACCESS PANELS WILL BE PROVIDED UNDER THE GENERAL SECTION OF
CONSTRUCTION AND SHALL BE MINIMUM OF 24" X 24" UNLESS OTHERWISE
INDICATED. COORDINATE WITH GENERAL CONTRACTOR.
* NEW 17 THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS
AND DIMENSIONS. NOTIFY THE A/E IMMEDIATELY OF ANY DISCREPANCIES.
* NEW 18 WHERE NEW SERVICES ARE SHOWN CONNECTING TO EXISTING, VERIFY EXACT
LOCATION AND SIZE OF EXISTING.
* NEW 19 EXISTING SERVICES SHALL BE MAINTAINED UNLESS OTHERWISE INDICATED.
* NEW 20 ALL DUCTS, PIPING, FIXTURES, ETC., WHICH ARE DASHED AND/OR INDICATED BY
NOTE ON DEMOLITION PLANS SHALL BE REMOVED.
* NEW 21 ALL PLUMBING SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE WITH
NATIONAL, STATE, AND LOCAL CODES.
* NEW 22 SEAL ALL SHEET METAL DUCTWORK JOINTS.
* NEW 23 WHERE MATERIAL IS INDICATED TO BE REMOVED, IT SHALL REMAIN THE
PROPERTY OF THE OWNER. THIS CONTRACTOR SHALL DISPOSE OF MATERIAL
AS DIRECTED BY THE OWNER.
* NEW 24 BALANCING OF AIR AND HYDRONIC SYSTEMS SHALL BE PERFORMED BY AN
NEBB OR AABC CERTIFIED TEST AND BALANCE AGENCY.
* NEW 25 PIPE PENETRATIONS OF RATED WALLS AND FLOORS SHALL BE SLEEVED AND
PROPERLY FIRE SEALED.
* NEW 26 ALL PIPE AND DUCT PENETRATIONS OF SMOKE PARTITION WALLS SHALL BE
PROPERLY SEALED TO RESIST THE PASSAGE OF SMOKE AS REQUIRED BY THE
LOCAL AUTHORITY.
* NEW 27 INSTALL FLUSH VALVE OPERATORS ON WIDE SIDE OF ACCESSIBLE STALLS.
* NEW 28 THE HEATING AND/OR COOLING HYDRONIC SYSTEM SHALL BE PROVIDED AND
FILLED WITH AN ANTIFREEZE GLYCOL SOLUTION (AS INDICATED ON THE
EQUIPMENT SCHEDULES) BY THE PIPING CONTRACTOR WHO SHALL BE
RESPONSIBLE FOR DETERMINING THE AMOUNT OF GLYCOL REQUIRED.
* NEW 29 GREASE DUCTS: PROVIDE 2-INCH THICK U.L. 2-HOUR FIRE RATED DUCT WRAP
ON GREASE DUCTS BETWEEN CEILING AND ROOF PENETRATION.
* NEW 30 MECHANICAL CONTRACTOR SHALL PROVIDE BALANCING DAMPERS WHERE
INDICATED. IN ADDITION CONTRACTOR SHALL PROVIDE BALANCING DAMPERS
ON DUCT TAKE-OFFS TO DIFFUSERS, GRILLES, AND REGISTERS, REGARDLESS
OF WHETHER DAMPERS ARE SPECIFIED AS PART OF THE DIFFUSER, GRILLE, OR
REGISTER ASSEMBLY. THE BALANCING DAMPER SHALL BE LOCATED IN THE
DUCT IMMEDIATELY AFTER THE DUCT TAKE-OFF AT THE MAIN DUCT
CONNECTION.
SHEET INDEX - MECHANICAL
D D
Is su e
C D
Is su e
SHEET # SHEET NAME
M-001 MECHANICAL TITLE SHEET
PD100 PLUMBING DEMOLITION PLAN - ADDITION CRAWLSPACE
PD101 PLUMBING DEMOLITION PLAN - ADDITION FIRST LEVEL
PL100 PLUMBING PLAN - ADDITION CRAWLSPACE
PL101 PLUMBING PLAN - ADDITION FIRST LEVEL
PL110 PLUMBING ROOF PLAN
PL601 PLUMBING SCHEDULES
M-100 OVERALL CRAWL SPACE PIPING PLAN
M-101 OVERALL BUILDING PIPING PLAN
MD101 MECHANICAL DEMOLITION PLAN - ADDITION FIRST LEVEL
MH100 MECHANICAL HVAC PLAN - ADDITION CRAWLSPACE
MH101 MECHANICAL HVAC PLAN - ADDITION FIRST LEVEL
MP100 MECHANICAL PIPING PLAN - ADDITION CRAWLSPACE
MP101 MECHANICAL PIPING PLAN - ADDITION FIRST LEVEL
M-120 MECHANICAL ROOF PLAN
M-601 MECHANICAL SCHEDULES
MARK DATE DESCRIPTION
DD MM/DD/YY DESIGN
DEVELOPMENT
M
1 2 3
C
B
A
1.7
A.3
B.5
A.9
SHARED
OFFICE
LOUNGE 337
SHARED STOR
LAB
MED. ALC.
EXAM
EXAM
CORR.
CORR.
N.S.
EXAM
EXAM
TREAT/ PROC
OFFICE
FAMILY TLT
CORR.
NURSING
SOIL
CLEAN
STORAGE
X-RAY
HALL
SUP.OFF.
EXAM
EXAM
EXAM
TLT
HALL
VITALS
O.P.D SUB-WAIT
N.S.
EXAM
C-3
CORRIDOR
RECORD STOR
RECPT.
C-2
CORRIDOR
DENTAL
RECEPT.
DENT. OPER
DENT. OPER
DENT. OPER
DENT. OPER
LKR.
JANITOR
STORAGE
DENT. OPER
DENT. OPER
323A
VEST.
CORR.
10"x10" S/A
20"x10" S/A
10"x8" E/A
12"x14" S/A
10"x8" E/A 20"x10" E/A10"x8" E/A
10"x8" E/A
10"x10" S/A
2 2
S-1
R-2
S-2
R-2
S-1
R-1
S-2
R-2
R-4
S-5
R-2
S-2
S-4
R-3
S-5
S-1
R-1
S-1 100S-1
S-3
R-1
S-1
S-2
S-1
S-2
S-2
R-2
R-1
S-1
R-2
R-1
R-2
S-2
R-2
R-2
R-4
S-2
VAV-338VAV-335
VAV-334
VAV-330
VAV-332
VAV-326
VAV-327
VAV-322
VAV-324
VAV-320VAV-321
18"x12" S/A 14"x10" S/A
10"x10" S/A 8"x10" S/A
12"x10" S/A
"x
S /A
"x
S /A
R-1
8"x10" R/A10"x12" R/A
"x
R /A
"x
R /A
"x
R /A
"x
R /A
18"x14" R/A
"x
R /A
"x
R /A
16"x12" R/A16"x14" R/A
"x
R /A
"x
R /A
R-5
R-5
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NO
T
FO
R
CO
NSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/7
/2
:0
:1
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic M m a k s c h .r v t
MECHANICAL HVAC
PLAN - ADDITION
FIRST LEVEL
MH101
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
CHM04/07/2017
SMT03161153
KEYNOTES
1 CAP DUCT TAKEOFF AT MAIN.
2 ADJUST EXISTING AIR DEVICE TO FIT IN NEW CEILING GRID.
3 RELOCATE EXISTING EXHAUST AIR DEVICE TO FIT IN NEW CEILING GRID. BALANCE
TO 50 CFM.
MARK DATE DESCRIPTION
SCALE: 3/16" = 1'-0"
A1
HVAC PLAN - FIRST LEVEL
TT
T
T T
T
T T
T
T
T 1 2 3
C
B
A
1.7
A.3
B.5
A.9
2 1/2" HWR
2" HWS
1 1/2" HWS
1" HWS
1" HWS 3/4" HWS
1 1/2" HWR 1 1/2" HWR 1 1/2" HWR
2" HWS
2 1/2" HWR
1 1/2" HWR
1 1/4" HWR
1 1/4" HWS
1 1/4" HWR
1 1/4" HWS
1" HWR
1 1/2" HWS
3/4" HWR
1 1/2" HWS 3/4" HWS
3/4" HWR
2" CWS 2" CWR
2" CWR
2" CWS
2" CWR
2" CWS
SHARED
OFFICE
LOUNGE
SHARED STOR
LAB
MED. ALC.
EXAM
EXAM
CORR.
CORR.
N.S.
EXAM
EXAM
TREAT/ PROC
OFFICE
FAMILY TLT
CORR.
NURSING
SOIL
CLEAN
STORAGE
X-RAY
HALL
SUP.OFF.
EXAM
EXAM
EXAM
TLT
HALL
VITALS
O.P.D SUB-WAIT
N.S.
EXAM
C-3
CORRIDOR
RECORD STOR
RECPT.
C-2
CORRIDOR
DENTAL
RECEPT.
DENT. OPER
DENT. OPER
DENT. OPER
DENT. OPER
LKR.
JANITOR
STORAGE
DENT. OPER
DENT. OPER
323A
VEST.
CORR.
VAV-338
VAV-335
VAV-334
VAV-330
VAV-332
VAV-326
VAV-327
VAV-322
VAV-324
VAV-320
VAV-321
RP-1
RP-1
RP-1
RP-1
RP-1
RP-1
RP-1
RP-1
RP-1
RP-1 RP-1
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NO
T
FO
R
CO
NSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/7
/2
:0
:2
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic M m a k s c h .r v t
MECHANICAL PIPING
PLAN - ADDITION
FIRST LEVEL
MP101
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
CHM04/07/2017
SMT03161153
KEYNOTES
SCALE: 3/16" = 1'-0"
A1
HYDRONIC PIPING PLAN - FIRST LEVEL
1 2 3
C
B
A
1.7
A.3
B.5
A.9
ROOF
CC-1
HC-1
RF-1
SF-1
EF-2
EF-1
EF-3
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NO
T
FO
R
CO
NSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/7
/2
:0
:0
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic M m a k s c h .r v t
MECHANICAL ROOF
PLAN
M-120
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
CHM04/07/2017
SMT03161153
KEYNOTES
MARK DATE DESCRIPTION
SCALE: 3/16" = 1'-0"
MECHANICAL PLAN - ROOF
NORTH
(ACTUAL)
NORTH
(REFERENCE)
ISSUES
SHEET NUMBER
SHEET TITLE
A
2 3
1 2 3
4 5
4 5
A
TSP, Inc.
PROJECT
NO
T
FO
R
CO
NSTR
UCTI
O N
600 Kansas City St.
Rapid City, SD 57701
(605) 343-6102 www.teamtsp.com
C C
B B
D D
© TSP, Inc. 2017
ISSUE DATE
CHECKED BY
DRAWN BY
PROJECT #
LI
S
TE
D
D R
A W
IN
G
S S
C A
LE
(S
) U N
LE
S
S R
E D
U C
E D
F R
O M
O R
IG
IN
A L x
F O
R M
A T
CONSULTANTS
Architecture Engineering
Planning
KEY PLAN
EXTG. BLDG.
NEW ADDITION
/7
/2
:0
:0
P
M
I:
T S
P R e v it L o c a l\
D a k o ta P la in s
K y le
C lin ic M m a k s c h .r v t
MECHANICAL
SCHEDULES
M-601
0%
D E
S
IG
N D
O C
U M
E N
T S
Kyle, South Dakota
KYLE CLINIC HEALTH
CENTER ADDITION -
IHS
DAKOTA PLAINS
CHM04/07/2017
SMT03161153
MARK DATE DESCRIPTION
AIR HANDLING UNIT SCHEDULE
MECHANICAL REQUIREMENTS ELECTRICAL REQUIREMENTS
UNIT NO. LOCATION
AREA
SERVED MANUFACTURER MODEL NO. AIRFLOW
MIN. OA
AIRFLOW
FANS COILS
ENERGY
RECOVERY ECONOMIZER FILTER
UNIT
WEIGHT
MECHANICAL
NOTES VOLTAGE PHASESUPPLY FAN RETURN FAN
COOLING
COIL
HEATING
COIL
AHU-1 ROOF ADDITION DAIKIN APPLIED OAH008GDAC 3,135 CFM 793 CFM SF-1 RF-1 CC-1 HC-1 - YES MERV 12 4,581 lb ALL 208 V 3
AHU SUPPLY FAN SCHEDULE
MECHANICAL REQUIREMENTS ELECTRICAL REQUIREMENTS
UNIT
NO. MANUFACTURER SERVES AIRFLOW
TOTAL
SP
EXTERNAL
SP
FAN
RPM BHP HP
MOTOR
RPM VFD FAN TYPE
FAN
CLASS
WHEEL
DIA.
MECHANICAL
NOTES VOLT/PH FLA MOCP
WIRE SIZE /
CONDUIT
CONTROLLER CONTROL
BY
DISCONNECT ELECTRICAL
NOTESTYPE SIZE LOCATION CTL DEVICE AUX BY TYPE BY
SF-1 DAIKIN APPLIED AHU-1 3,135 CFM 5.00 in-wg 2.00 in-wg 3072 4.02 5 1750 NEMA 3R CENTRIFIGUAL DWDI 2 13.2" 208/3 17.5 35 A SEE SCHEDULE VFD - INT - - DIV. 23 BMS INT DIV. 23
AHU RETURN FAN SCHEDULE
MECHANICAL REQUIREMENTS ELECTRICAL REQUIREMENTS
UNIT
NO. MANUFACTURER SERVES AIRFLOW TOTAL SP
EXTERNAL
SP
FAN
RPM HP BHP
MOTOR
RPM VFD FAN TYPE
FAN
CLASS
WHEEL
DIA.
MECHANICAL
NOTES VOLT/PH FLA MOCP
WIRE SIZE /
CONDUIT
CONTROLLER CONTROL
BY
DISCONNECT ELECTRICAL
NOTESTYPE SIZE LOCATION CTL DEVICE AUX BY TYPE BY
RF-1 DAIKIN APPLIED AHU-1 3,135 CFM 1.18 in-wg 1.00 in-wg 2307 2.0 1.4 1750 NEMA 3R CENTRIFUGAL DWDI 1 13.2" 208/3 7.8 20 SEE SCHEDULE VFD - INT - - DIV. 23 BMS INT DIV. 23
HEATING WATER COIL SCHEDULE
COIL NO. SERVES
MANUFACTURER
MODEL NO. TYPE AIRFLOW
CAPACITY
MBH
AIR SIDE WATER SIDE
MECHANICAL
NOTES
FACE
VELOCIT
Y EAT DB LAT DB AIR PD EWT LWT GPM WATER PD PG% ROWS
HC-1 AHU-1 DAIKIN APPLIED HW 3,135 CFM 59.1 448 FPM 49.0 °F 67.9 °F 0.10 in-wg 180 °F 156 °F 5.6 GPM 0.1 ftH2O 50 2
COOLING WATER COIL SCHEDULE
COIL NO. SERVES
MANUFACTURER
MODEL NO. TYPE AIRFLOW
TOTAL CAP.
MBH
AIRSIDE WATERSIDE
MECHANICAL
NOTES
FACE
VELOCIT
Y EAT DB EAT WB LAT DB LAT WB AIR PD EWT LWT GPM WATER PD FLUID ROWS
CC-1 AHU-1 DAIKIN APPLIED CW 3135 CFM 112 418 FPM 80.0 °F 66.0 °F 54.1 °F 53.9 °F 0.75 in-wg 45 °F 55 °F 23.2 GPM 12.6 ftH2O 30% PG 8
VARIABLE AIR VOLUME TERMINAL UNIT SCHEDULE
UNIT NO. MANUFACTURER
MODEL
NO.
MAXIMUM
AIRFLOW
MINIMUM
AIRFLOW
INLET
DIAMETE
R INLET SP
MAX.
BOX NC
AIRSIDE HOT WATER
MECHANICAL
NOTESHEATING CAP. (MBH) HEATING AIRFLOW EAT LAT FLOW PIPE DIAMETER
VAV-320 KRUEGER LMHS 215 CFM 107 CFM 5" 1.5 in-wg 25 5.2 107 CFM 55.0 °F 100.0 °F 0.5 GPM 1/2" ALL
VAV-321 KRUEGER LMHS 140 CFM 70 CFM 4" 1.5 in-wg 25 3.4 70 CFM 55.0 °F 100.0 °F 0.3 GPM 1/2" ALL
VAV-322 KRUEGER LMHS 215 CFM 108 CFM 4" 1.5 in-wg 25 6.4 108 CFM 55.0 °F 110.0 °F 0.6 GPM 1/2" ALL
VAV-324 KRUEGER LMHS 190 CFM 95 CFM 4" 1.5 in-wg 25 4.6 95 CFM 55.0 °F 100.0 °F 0.5 GPM 1/2" ALL
VAV-326 KRUEGER LMHS 470 CFM 235 CFM 6" 1.5 in-wg 25 11.4 235 CFM 55.0 °F 100.0 °F 1.1 GPM 3/4" ALL
VAV-327 KRUEGER LMHS 420 CFM 210 CFM 6" 1.5 in-wg 25 12.5 210 CFM 55.0 °F 110.0 °F 1.2 GPM 3/4" ALL
VAV-330 KRUEGER LMHS 400 CFM 200 CFM 6" 1.5 in-wg 25 9.7 200 CFM 55.0 °F 100.0 °F 1.0 GPM 3/4" ALL
VAV-332 KRUEGER LMHS 385 CFM 193 CFM 6" 1.5 in-wg 25 9.4 193 CFM 55.0 °F 100.0 °F 0.9 GPM 3/4" ALL
VAV-334 KRUEGER LMHS 225 CFM 113 CFM 4" 1.5 in-wg 25 6.7 113 CFM 55.0 °F 110.0 °F 0.7 GPM 1/2" ALL
VAV-335 KRUEGER LMHS 310 CFM 155 CFM 6" 1.5 in-wg 25 9.2 155 CFM 55.0 °F 110.0 °F 0.9 GPM 3/4" ALL
VAV-338 KRUEGER LMHS 165 CFM 83 CFM 5" 1.5 in-wg 25 4.9 83 CFM 55.0 °F 110.0 °F 0.5 GPM 1/2" ALL
EXHAUST FAN & POWER ROOF VENT SCHEDULE
MECHANICAL REQUIREMENTS ELECTRICAL REQUIREMENTS
UNIT NO. LOCATION SERVES MANUFACTURER MODEL NO. TYPE AIRFLOW TSP RPM POWER SONES
MECHANICAL
NOTES VOLT/PH FLA
WIRE SIZE /
CONDUIT
CONTROLLER CONTRO
L BY
DISCONNECT ELECTRICAL
NOTESTYPE SIZE LOCATION CTL DEVICE AUX BY TYPE BY
EF-1 ROOF 325, 331 COOK 70C2B DOWNBLAST 220 CFM 0.38 in-wg 1725 0.17 hp 9 1,2,3,4 120/1 SEE SCHEDULE - - - - - - DIV. 23 INT DIV. 23
EF-2 ROOF 322 COOK 70C2B DOWNBLAST 265 CFM 0.50 in-wg 1725 0.25 hp 12 1,2,3,5 120/1 SEE SCHEDULE - - - - - - DIV. 26 INT DIV. 23 E1
EF-3 ROOF 338 COOK 70C2B DOWNBLAST 265 CFM 0.50 in-wg 1725 0.25 hp 12 1,2,3,4 120/1 SEE SCHEDULE - - - - - - DIV. 23 INT DIV. 23
MECHANICAL NOTES:
1. UNIT SHALL BE HORIZONTAL OUTDOOR UNIT MOUNTED ON ROOF, RF AND SF VFD, DRAW THROUGH, LOW/MEDIUM PRESSURE.
2. UNIT SHALL BE COMPLETE WITH MIXING BOX, FACE AND BYPASS DAMPERS, ACCESS SECTIONS.
3. PREFILTERS SHALL BE THROW AWAY, 2" OR 4" THICK, MINIMUM 30% EFFICIENCY BASED ON DOP METHOD, APD=0.50 (MAXIMUM).
4. FINAL FILTERS SHALL BE THROW AWAY, MINIMUM 90% EFFICIENCY BASED ON DOP METHOD, APD=0.50 (MAXIMUM).
5. PREHEAT HW COIL 50% PG, CHILLED WATER COIL 30% PG.
6. PROVIDE INTEGRAL DISCONNECT FOR SUPPLY FAN AND RETURN FAN.
7. PROVIDE 120V CONVENIENCE OUTLET. PROVIDE WEATHERPROOFGFCI WITH IN-USE COVER.
8. PROVIDE 24" CURB TO MATCH UNIT FOOTPRINT.
MECHANICAL NOTES:
1.
ELECTRICAL NOTES:
1.
MECHANICAL NOTES:
1.
ELECTRICAL NOTES:
1.
MECHANICAL NOTES:
1.
MECHANICAL NOTES:
1.
MECHANICAL NOTES:
1. PROVIDE BIRDSCREEN AND BACKDRAFT DAMPER.
2. PROVIDE ROOF CURB DESIGNED TO MATE WITH UNIT.
3. PROVIDE FLEXIBLE DUCT CONNECTIONS AT FAN INLET.
4. CONTROL ON BAS.
5. WALL SWITCH, BAS SHALL CLOSE RETURN AIR DAMPER WHEN ENERGIZED.
6. PROVIDE FACTORY MOUNTED DISCONNECT.
ELECTRICAL NOTES:
1. DIV. 26 TO PROVIDE TOGGLE SWITCH IN ROOM FOR FAN CONTROL.
MECHANICAL NOTES:
1. NOISE CRITERIA IS BASED ON 1.0" APR AIR TERMINAL STATIC PRESSURE DROP AND THE SCHEDULED NC VALUES ARE RADIATED
NC'S WITH NO SOUND ATTENUATORS, NO LINED DUCTWORK, NO MULTIPLE TAKEOFF ALLOWANCE, AND NO ROOM ABSORPTION.
2. INSULATION SHALL NOT BE EXPOSED TO THE AIR STREAM.
3. INLET AND OUTLET DUCT SIZES SHALL MATCH VAV INLET AND OUTLET UNLESS OTHERWISE NOTED ON DRAWINGS.
4. PRESSURE DROP OF VAV BAX SHALL NOT EXCEED 0.4 INCHES AT DESIGN CFM.
5. CONTRACTOR SHALL ALLOW 5 STRAIGHT DUCT DIAMTERS ON VAV INLET WHEN POSSIBLE.
6. PROVIDE A COIL ACCESS DOOR, AND AN EMPTY BOX FOR DDC CONTROLS BY TEMPERATURE CONTROLS CONTRACTOR.
7. HWS AND HWR RUNOUTS TO HEATING COIL SHALL BE AS NOTED ON PLANS, OR PER SCHEDULE WHICHEVER IS LARGEST.
8. TWO ROW HOT WATER COIL.
GRILLES, REGISTERS AND DIFFUSERS SCHEDULE
TYPE SYSTEM MANUFACTURER MODEL NO. FACE SIZE NECK SIZE
MOUNTING
TYPE SPECIFICATION
MAX NC
(dB)
MAX PD
("WG)
INTEGRAL
DAMPER FINISH COLOR MATERIAL REMARKS
S-1 SUPPLY KRUEGER SHPCR 24x24 6"Ø LAY-IN LOUVER FACE, ROUND NECK, VERT/HORIZ ADJ AIRFLOW, 10 FT VERT THROW 20 0.05 - WHITE STEEL
S-2 SUPPLY KRUEGER SHPCR 24x24 8"Ø LAY-IN LOUVER FACE, ROUND NECK, VERT/HORIZ ADJ AIRFLOW, 10 FT VERT THROW 20 0.05 - WHITE STEEL
S-3 SUPPLY KRUEGER SHPCR 24x24 10"Ø LAY-IN LOUVER FACE, ROUND NECK, VERT/HORIZ ADJ AIRFLOW, 10 FT VERT THROW 20 0.05 - WHITE STEEL
S-4 SUPPLY KRUEGER SHPCR 24x24 12"Ø LAY-IN LOUVER FACE, ROUND NECK, VERT/HORIZ ADJ AIRFLOW, 10 FT VERT THROW 20 0.05 - WHITE STEEL
S-5 SUPPLY KRUEGER SHPCR 12x12 8"Ø SURFACE LOUVER FACE, ROUND NECK, VERT/HORIZ ADJ AIRFLOW, 10 FT VERT THROW 20 0.05 - WHITE STEEL
M15 EXHAUST KRUEGER EGC15 12x12 10"x10" SURFACE 1/2"X1/2"X1" CUBE CORE, 1" FRAME 20 0.12 - WHITE ALUMINUM
R-4 RETURN KRUEGER EGC15 12x12 8"x8" SURFACE 1/2"X1/2"X1" CUBE CORE, 1" FRAME 20 0.12 - WHITE ALUMINUM
R-5 RETURN KRUEGER EGC15 12x12 10"x10" SURFACE 1/2"X1/2"X1" CUBE CORE, 1" FRAME 20 0.12 - WHITE ALUMINUM
R-1 CEILING RETURN / TRANSFER
GRILLE
KRUEGER EG5 24 x 24 8"Ø LAY-IN 1/2" x 1/2" x 1" EGGCRATE GRID. 0 0.00 --- WHITE ENAMEL ALUMINUM
R-2 CEILING RETURN / TRANSFER
GRILLE
KRUEGER EG5 24 x 24 10"Ø LAY-IN 1/2" x 1/2" x 1" EGGCRATE GRID. 0 0.00 --- WHITE ENAMEL ALUMINUM
R-3 CEILING RETURN / TRANSFER
GRILLE
KRUEGER EG5 24 x 24 12"Ø LAY-IN 1/2" x 1/2" x 1" EGGCRATE GRID. 0 0.00 --- WHITE ENAMEL ALUMINUM
HYDRONIC RADIANT CEILING PANEL SCHEDULE
UNIT NO. MANUFACTURER MODEL NO. TYPE LENGTH WIDTH GPM/CIRCUIT BTU/LF WPD/LF GLYCOL AVE WTR TEMP AVE AIR TEMP FINISH MECH REMARKS
RP-1 AIRTEX HEF AS NOTED ON PLANS 24", 3-TUBE 0.0 GPM 0 0.00 ftH2O 0% -460 °F 70.0 °F WHITE
E - 5 0 1
A N N NA
SHEET SEQUENCE
NUMBER 01-99
SHEET TYPE
DESIGNATOR
DISCIPLINE
CHARACTER
MODIFIER
CHARACTER
SHEET TYPE DESIGNATORS
0 GENERAL (SYMBOLS LEGEND)
1 PLANS (HORIZONTAL VIEWS)
2 ELEVATIONS (VERTICAL VIEWS)
3 SECTIONS (SECTIONAL VIEWS)
4 LARGE SCALE VIEWS
5 DETAILS
6 SCHEDULES AND DIAGRAMS
7 USER DEFINED
8 USER DEFINED
9 3D REPRESENTATIONS
1 2 3 4 5 6
E2 E3 E4
C5
A4A1
A
B
C
D
E
TSP
A
B
C
D
E
1 2 3 4 5 6
DISCIPLINE CHARACTERS
S SITE
D DEMOLITION
L LIGHTING
P POWER
Y AUXILIARY
I INSTRUMENTATION
T TELECOMMUNICATION
SHEET IDENTIFICATIONELECTRICAL ABBREVIATIONS LIST
1P 1 POLE (2P, 3P, 4P, ETC.)
A AMPERE
AC AIR CONDITIONER
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFI ARC FAULT CIRCUIT
INTERRUPTER
AHU AIR HANDLING UNIT
AIC AVAILABLE INTERRUPTING FAULT
CURRENT
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMPL AMPLIFIER
ANNUN ANNUNCIATOR
APPROX APPROXIMATELY
AQ-STAT AQUASTAT
ARCH ARCHITECT, ARCHITECTURAL
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BD BOARD
BLDG BUILDING
BMS BUILDING MANAGEMENT
SYSTEM
C CONDUIT
CAB CABINET
CAT CATALOG
CATV CABLE TELEVISION
CB CIRCUIT BREAKER
CB-XX RECESSED CEILING BOX (SEE SCHEDULE)
CCTV CLOSED CIRCUIT TELEVISION
CKT CIRCUIT
CLG CEILING
CM CORNER MOUNT
CMPR COMPRESSOR
COMB COMBINATION
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUATION OR
CONTINUOUS
CONTR CONTRACTOR
CP CIRCULATING PUMP
CRT CATHODE-RAY TUBE
CT CURRENT TRANSFORMER
CTR CENTER
CU COPPER
DCP DOMESTIC WATER
CIRCULATING PUMP
DEPT DEPARTMENT
DIA DIAMETER
DISC DISCONNECT
DIST DISTRIBUTION
DN DOWN
DT DOUBLE THROW
DTS DUAL TECHNOLOGY SENSOR
DWG DRAWING
EC ELECTRICAL CONTRACTOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EMS ENERGY MANAGEMENT SYSTEM
EMT ELECTRICAL METALLIC TUBING
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXH EXHAUST
EXP EXPLOSION PROOF
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FB-XX FLOOR BOX (SEE SCHEDULE)
FCU FAN COIL UNIT
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FU FUSE
FVNR FULL VOLTAGE NON-REVERSING
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GFI/GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GFP GROUND FAULT PROTECTOR
GND GROUND
GRS GALVANIZED RIGID STEEL
(CONDUIT)
GYP BD GYPSUM BOARD
HOA HANDS-OFF-AUTOMATIC
SWITCH
HORIZ HORIZONTAL
HP HORSEPOWER
HT HEIGHT
HTG HEATING
HTR HEATER
HV HIGH VOLTAGE
HVAC HEATING, VENTILATING AND
AIR CONDITIONING
HWP HYDRONIC WATER PUMP
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
I/W INTERLOCK WITH
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KVAR KILOVOLT-AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LOC LOCATE OR LOCATION
LT LIGHT
LTG LIGHTING
LTNG LIGHTNING
LV LOW VOLTAGE
MAX MAXIMUM
MAG.S MAGNETIC STARTER
M/C MOMENTARY CONTACT
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDC MAIN DISTRIBUTION CENTER
MDP MAIN DISTRIBUTION PANEL
MFR MANUFACTURER
MFS MAIN FUSED DISCONNECT
SWITCH
MH MANHOLE
MIC MICROPHONE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUGS ONLY
MMS MANUAL MOTOR STARTER
MOA MULTIOUTLET ASSEMBLY
MSP MOTOR STARTER PANELBOARD
MSB MAIN SWITCHBOARD
MT MOUNT
MT.C EMPTY CONDUIT
MTS MANUAL TRANSFER SWITCH
MTR MOTOR, MOTORIZED
N.C. NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NFDS NON-FUSED SAFETY
DISCONNECT SWITCH
NIC NOT IN CONTRACT
NL NIGHT LIGHT
N.O. NORMALLY OPEN
NTS NOT TO SCALE
OH OVERHEAD
OL OVERLOADS
OS OCCUPANCY SENSOR
PA PUBLIC ADDRESS
PB PULL BOX
PED PEDESTAL
PF POWER FACTOR
PH PHASE
PIR PASSIVE INFRARED
PIV POST INDICATING VALVE
PNL PANEL
PP POWER POLE
PR PAIR
PRI PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
(CONDUIT)
PWR POWER
QUAN QUANTITY
REC RECEPTACLE
REQD REQUIRED
RM ROOM
RSC RIGID STEEL CONDUIT
RTU ROOF TOP UNIT
SC SURFACE CONDUIT
SEC SECONDARY
SHT SHEET
SIM SIMILAR
S/N SOLID NEUTRAL
SPEC SPECIFICATION
SPKR SPEAKER
SP SPARE
SR SURFACE RACEWAY
SS STAINLESS STEEL
SSW SELECTOR SWITCH
S/S STOP/START PUSHBUTTONS
STA STATION
STD STANDARD
SURF SURFACE MOUNTED
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
TEL TELEPHONE
TEL/DATA TELEPHONE/DATA
TERM TERMINAL
TL TWIST LOCK
TR TAMPER RESISTANT
T-STAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER
UE UNDERGROUND ELECTRICAL
UG UNDERGROUND
UH UNIT HEATER
UT UNDERGROUND TELEPHONE
UTIL UTILITY
UV UNIT VENTILATOR OR
ULTRAVIOLET
V VOLT
VA VOLT-AMPERES
VDT VIDEO DISPLAY TERMINAL
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
VS VACANCY SENSOR
W WATT
W/ WITH
WB-XX RECESSED WALL BOX (SEE SCHEDULE)
WG WIRE GUARD
WH WATER HEATER
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
XFR TRANSFER
Y WYE-CONNECTED
ANGLE
@ AT
DELTA
' FEET
" INCHES
# NUMBER
Ø PHASE
C CENTER LINE
P PLATE
ROOM TAG
REVISION TAG
KEYNOTE TAG
SECTION TAG
DETAIL TAG
ELEVATION TAG
EXISTING WORK
NEW WORK
EXISTING ITEMS TO BE REMOVED
NAME
A1
A-301
A1
A-501
A-201A1
NORTH ARROW
MATCH LINE
SEE - - - -
A1
PLAN OR DETAIL
SCALE: 1'-0" = 1'-0"
GRID COLUMN/FND GRID INDICATOR
MATCH LINE INDICATOR
DETAIL/SECTION/PLAN
INDICATOR
CONVENTIONS LEGEND
PLAN NORTH
MECHANICAL EQUIPMENT TAGX-#
A2
12b
E
16c
1,3,5
SF-1
2,4,6
LPN-102
ELECTRICAL SYMBOL…