Attachment J-2c ANC ATCT TRACON Drawings Vol 4.pdf

PDF 37 MB Posted

Attached to
Anchorage Airport Traffic Control Tower (ANC ATCT) and Anchorage Terminal Radar Approach Control/Base Building (A11 TRACON)
Solicitation number
697DCK-25-R-00074
Issued by

About this file

This file appears to be a volume of technical drawings (Volume 4) related to the Anchorage Airport Traffic Control Tower (ANC ATCT) and Terminal Radar Approach Control (TRACON) facility construction project. Since this is marked as "Attachment J-2c" and contains drawings, it serves as a technical reference document providing architectural and engineering specifications for the construction project rather than containing specific requirements or instructions for contractors.

The file is referenced as part of solicitation number 697DCK-25-R-00074 issued by the FAA Southwestern Region for the construction of a new Airport Traffic Control Tower and TRACON facility at Ted Stevens International Airport in Anchorage. Without access to the actual drawings, no further details about the specific technical content can be provided.

View the file

Other files

File Type Posted
QUESTIONS and RESPONES Jan 30 2025.pdf PDF
01 40 00_Contractor_Quality_Control_Rev 1_Amend 0003.pdf PDF
22 11 23.13_domestic-water_packaged_booster_pumps_Rev 1_Amend 0003.pdf PDF
697DCK-25-R-00074 Amend 0002.pdf PDF
01 31 00_Project_Management_and_Coordination_Rev 1_Amend 0003.pdf PDF
Zoom Meeting Attendence.pdf PDF
697DCK-25-R-00074 Amend 0003.pdf PDF
697DCK-25-R-00074 Amend 0002.pdf PDF
FINANICAL CAPABILITY FORM.pdf PDF
Zoom Meeting Attendence.pdf PDF
697DCK-25-R-00074 Amend 0001.pdf PDF
Attachment J-2d ANC ATCT TRACON Drawings Vol 5.pdf PDF
Attachment J-3a ANC ATCT and TRACON Final Specs Vol 2.pdf PDF
Attachment J-2b ANC ATCT TRACON Drawings Vol 3.pdf PDF
Attachment J-7 Price Proposal.xlsx XLSX spreadsheet
Attachment J-3c ANC ATCT TRACON Final Spec Vol 4.pdf PDF
Attachment J-6 Wage Determination.pdf PDF
Attachment J-4 ANC ATCT TRACON BOD Final.pdf PDF
Attachment J-1 ANC ATCT TRACON Statement of Work.pdf PDF
Attachment J-3b ANC ATCT TRACON Final Spec Vol 3.pdf PDF
697DCK-25-R-00074_Final.pdf PDF
Attachment J-2a ANC ATCT TRACON Drawings Vol 2.pdf PDF
PAST PERFORMANCE QUESTIONNAIRE.pdf PDF
Attachment J-2 ANC ATCT TRACON Drawings Vol 1.pdf PDF
Attachment J-3 ANC ATCT TRACON Final Spec Vol 1.pdf PDF
Attachment J-2e ANC ATCT TRACON Drawings Vol 6.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KODIAK

ANCHORAGE

FAIRBANKS

JUNEAU

130°140°150°160°170°

170° 160° 150° 140° 130° 120°70°

65°

60°

55°

60°

65°

70°180°

Project Location

SCALE : NOT TO SCALE

ALASKA LOCATION MAP

SEWARD

TOK

GLENALLEN

NOME

BETHEL

KOTZEBUE

UTQIAGVIK

DEADHORSE

VALDEZ

DUTCH HARBOR

Project Location

SCALE : NOT TO SCALE

ANCHORAGE VICINITY MAP

C H

U G

A C

H M

O U

N T

A

IN

S

TUDOR ROAD

CAMPBELL CREEK

L A

K E

O T

IS

P

K W

Y

O L D

S E

W A

R D

H W

Y

DOWLING ROAD

RASPBERRY ROAD

A R

C T

IC

B

L V

D

C S

T R

E E

T

M

IN

N E

S O

T A

D R

N E

W S

E W

A R

D H

W Y

K N

IK

A R M

WESTCHESTER

LAGOON

PORT OF

ANCHORAGE

AK RAILROAD

POST R

OAD

COMMERCIAL DR

TED STEVENS

INTERNATIONAL AIRPORT

J E

W E

L L

A K

E R

O A

D

INT. AIRPORT ROAD

LAKE

HOOD

P O

S T

M A

R K

D R

IV

E

NORTHERN LIGHTS BLVD.

SPENARD R

OAD

FIREWEED LANE

BENSON BLVD

36TH AVENUE

U A

A

D R

IV

E

CHESTER

CREEK

B R

A G

A W

S

T R

E E

T

DEBARR ROAD

A

IR

P O

R T

H E

IG

H

T S

L S

T R

E E

T

I S

T R

E E

T E

S T

15TH AVENUE

G A

M B

E L L

S T

R E

E T

C S

T

A S

T

IN

G

R A

S T

R E

E T

MERRILL

FIELD

SHIP CREEK

GLENN HWY

(TO M

AT-SU, F

AIRBANKS,

VALDEZ, A

ND ALASKA HWY)

4TH AVENUE

5TH AVENUE

6TH AVENUE

R E

E V

E B

L V

D

O'MALLEY ROAD

ABBOTT ROAD

KINCAID PARK

T O

K E N

A I, S

E W

A R

D

A N

D H

O M

E R

S A

N D

L A

K E

R O

A D

S O

U T H

P O

R T D

R

N O

R T

H W

O O

D S

T

STRAWBERRY RD

W 88TH AVE

W KLATT RD

DIMOND BLVD

HUFFMAN RD

De ARMOUN RD

E L M

O R

E R

O A

D

JOINT BASE ELMENDORF - RICHARDSON (JBER)

MOUNTAIN VIEW

M U

L D

O O

N R

O A

D

NORTHERN LIGHTS BLVD.

B O

N

IF

A C

E P

R K

W Y

C O O

K IN

LE

T

POINT McKENZIE

TURNAGAIN ARM

B

IR

C H

R O

A D

H

IL

L S

ID

E

D R

IV

E

DIMOND BLVD

E L M

O R

E R

O A

D

W

IS

C O

N S

IN

S

T

O C

E A

N D

O C

K R

D

MT. V

IEW

D R

M c C

A R

R E

Y S

T

MLK BLVD

W. 100TH

VOLUME INDEX

VOLUME 1: GENERAL

REAL ESTATE / LEASE

DEMOLITION

CIVIL

LANDSCAPING

VOLUME 2: ARCHITECTURAL

SIGNAGE

VOLUME 3: STRUCTURAL

VOLUME 4: MECHANICAL

PLUMBING

VOLUME 5: ELECTRICAL

VOLUME 6: TELECOMMUNICATIONS

AUDIO VISUAL

SECURITY

FIRE PROTECTION

FIRE ALARM

VERTICAL TRANSPORTATION

FOR OFFICIAL USE ONLY

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

/1

/2

:1

:0

P

M

G004

DRAWING COVER - VOL 4

SW

SW

KZ

06/11/2024

S U

B M

IT

T

A L

P H

A S

E

GENERAL

ANC New ATCT & TRACON/ Base Building

100% FINAL SUBMITTAL

VOLUME 4

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

SENSITIVE SECURITY INFORMATION

WARNING: THIS RECORD CONTAINS SENSITIVE SECURITY INFORMATION THAT IS CONTROLLED

UNDER 49 CFR PARTS 15 AND 1520. NO PART OF THIS RECORD MAY BE DISCLOSED TO PERSONS

WITHOUT A "NEED TO KNOW", AS DEFINED IN 49 CFR PARTS 15 AND 1520, EXCEPT WITH THE

WRITTEN PERMISSION OF THE ADMINISTRATOR OF THE TRANSPORTATION SECURITY

ADMINISTRATION OR THE SECRETARY OF TRANSPORTATION. UNAUTHORIZED RELEASE MAY

RESULT IN CIVIL PENALTY OR OTHER ACTION. FOR U.S. GOVERNMENT AGENCIES, PUBLIC

DISCLOSURE IS GOVERNED BY 5 U.S.C. 552 AND 49 CFR PARTS 15 AND 1520.

FOR OFFICIAL USE ONLY

PUBLIC AVAILABILITY TO BE DETERMINED UNDER 5 USC 552

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

/1

/2

:1

:0

P

M

G024

DRAWING INDEX - VOL 4

SW

SW

KZ

06/11/2024

S U

B M

IT

T

A L

P H

A S

E

GENERAL

DRAWING INDEX - VOLUME 4

DRAWING INDEX

NO. DRAWING NAME

GENERAL - VOL 4

G004 DRAWING COVER - VOL 4

G024 DRAWING INDEX - VOL 4

MECHANICAL

M002 MECHANICAL LEGENDS & ABBREVIATIONS & SHEET INDEX

M201 OVERALL LEVEL 1 MECHANICAL PLAN

M202 BASE BUILDING LEVEL 1 MECHANICAL PLAN - AREA A

M203 BASE BUILDING & TOWER LEVEL 1 MECHANICAL PLAN - AREA B

M204 OVERALL LEVEL 2 MECHANICAL PLAN

M205 BASE BUILDING LEVEL 2 MECHANICAL PLAN - AREA A

M206 BASE BUILDING & TOWER LEVEL 2 MECHANICAL PLAN - AREA B

M207 BASE BUILDING OVERALL ROOF MECHANICAL PLAN

M208 TOWER LEVEL 1 & 2 - MECHANICAL PLAN

M209 TOWER LEVEL 3 & 3B - STAIR 1 FAN LEVEL MECHANICAL PLAN

M210 TOWER LEVEL 4 & 4B - STAIR 2 FAN LEVEL MECHANICAL PLAN

M211 TOWER LEVEL 5 - MECHANICAL PLAN

M212 TOWER LEVEL 6 & 6B - STAIR 1 FAN LEVEL MECHANICAL PLAN

M213 TOWER LEVEL 7 & 7B - STAIR 2 FAN LEVEL MECHANICAL PLAN

M214 TOWER LEVEL 8 - MECHANICAL PLAN

M215 TOWER LEVEL 9 - ELECTRICAL LEVEL MECHANICAL PLAN

M216 TOWER LEVEL 10 - ELECTRONICS LEVEL MECHANICAL PLAN

M217 TOWER LEVEL 11 - JUNCTION LEVEL MECHANICAL PLAN

M218 TOWER LEVEL 12 - CONSOLE ACCESS LEVEL MECHANICAL PLAN

M219 TOWER LEVEL 13 - CAB LEVEL MECHANICAL PLAN

M300 MECHANICAL SITE PLAN

M301 OVERALL LEVEL 1 PIPING PLAN

M302 BASE BUILDING LEVEL 1 PIPING PLAN - AREA A

M303 BASE BUILDING & TOWER LEVEL 1 PIPING PLAN - AREA B

M304 OVERALL LEVEL 2 PIPING PLAN

M305 BASE BUILDING LEVEL 2 PIPING PLAN - AREA A

M306 BASE BUILDING & TOWER LEVEL 2 PIPING PLAN - AREA B

M307 BASE BUILDING OVERALL ROOF PIPING PLAN

M308 TOWER LEVEL 1 & 2 - PIPING PLAN

M309 TOWER LEVEL 3 & 3B - STAIR 1 FAN LEVEL PIPING PLAN

M310 TOWER LEVEL 4 & 4B - STAIR 2 FAN LEVEL PIPING PLAN

M311 TOWER LEVEL 5 - PIPING PLAN

M312 TOWER LEVEL 6 & 6B - STAIR 1 FAN LEVEL PIPING PLAN

M313 TOWER LEVEL 7 & 7B - STAIR 2 FAN LEVEL PIPING PLAN

M314 TOWER LEVEL 8 - PIPING PLAN

M315 TOWER LEVEL 9 - ELECTRICAL LEVEL PIPING PLAN

M316 TOWER LEVEL 10 - ELECTRONICS LEVEL PIPING PLAN

M317 TOWER LEVEL 11 - JUNCTION LEVEL PIPING PLAN

M318 TOWER LEVEL 12 - CONSOLE ACCESS LEVEL PIPING PLAN

M400 MECHANICAL SECTIONS

M401 MECHANICAL SECTIONS

M402 MECHANICAL SECTIONS

M403 MECHANICAL SECTIONS

M404 MECHANICAL SECTIONS-BOILER RM

M405 MECHANICAL SECTIONS-ELECTRONIC EQUIPMENT RM

M406 MECHANICAL SECTIONS-ELECTRONIC EQUIPMENT RM II

M410 ENLARGED MECHANICAL PLANS

M420 ENLARGED PIPING PLANS I

M421 ENLARGED PLANS I CLEARANCES

M422 ENLARGED PIPING PLANS II

M601 MECHANICAL DIAGRAMS - PIPING

M602 MECHANICAL DIAGRAMS - AIR RISER

M603 MECHANICAL DIAGRAMS - HEATING & COOLING PLANT

M701 MECHANICAL SCHEDULES

M702 MECHANICAL SCHEDULES

M703 MECHANICAL SCHEDULES

M704 MECHANICAL SCHEDULES

M705 MECHANICAL SCHEDULES

M706 MECHANICAL SCHEDULES

M801 MECHANICAL DETAILS

M802 MECHANICAL DETAILS

M803 MECHANICAL DETAILS

M804 MECHANICAL DETAILS

M805 MECHANICAL DETAILS

M901 MECHANICAL CONTROLS LEGEND AND ABBREVIATIONS

M902 ERV CONTROLS

M903 FAN COIL AND CHILLED BEAM CONTROLS

M904 AHU AND VAV WITH HEATING COIL CONTROLS

DRAWING INDEX

NO. DRAWING NAME

M905 STAIR PRESSURIZATION AND VENT FAN CONTROLS

M906 MISCELLANEAOUS MECHANICAL CONTROLS

M907 CHILLER-HEATING PLANT CONTROLS DIAGRAM

M908 CHILLER-HEATING PLANT SEQUENCE OF OPERATIONS

M909 SNOW MELT SEQUENCE OF OPERATIONS

M910 AC UNIT

M911 GENERATOR VENTILATION AND LOAD SHEDDING CONTROLS

M912 UPS VENTILATION CONTROL

PLUMBING

P002 PLUMBING LEGENDS & ABBREVIATIONS

P200 OVERALL BELOW GRADE PLUMBING PLAN

P201 BELOW GRADE PLUMBING PLAN - AREA A

P202 BELOW GRADE PLUMBING PLAN - AREA B

P203 OVERALL LEVEL 1 PLUMBING PLAN

P204 BASE BUILDING LEVEL 1 PLUMBING PLAN - AREA A

P205 BASE BUILDING & TOWER LEVEL 1 PLUMBING PLAN - AREA B

P206 OVERALL LEVEL 2 PLUMBING PLAN

P207 BASE BUILDING LEVEL 2 PLUMBING PLAN - AREA A

P208 BASE BUILDING & TOWER LEVEL 2 PLUMBING PLAN - AREA B

P209 BASE BUILDING OVERALL ROOF & TOWER PLUMBING PLAN

P210 TOWER LEVEL 1 - PLUMBING PLANS

P211 TOWER LEVEL 2 - PLUMBING PLANS

P212 TOWER LEVEL 3 & 3B - STAIR 1 FAN LEVEL PLUMBING PLAN

P213 TOWER LEVEL 4 & 4B - STAIR 2 FAN LEVEL PLUMBING PLAN

P214 TOWER LEVEL 5 - PLUMBING PLAN

P215 TOWER LEVEL 6 & 6B - STAIR 1 FAN LEVEL PLUMBING PLAN

P216 TOWER LEVEL 7 & 7B - STAIR 2 FAN LEVEL PLUMBING PLAN

P217 TOWER LEVEL 8 - PLUMBING PLAN

P218 TOWER LEVEL 9 - ELECTRICAL LEVEL PLUMBING PLAN

P219 TOWER LEVEL 10 - ELECTRONICS LEVEL PLUMBING PLAN

P220 TOWER LEVEL 11 - JUNCTION LEVEL PLUMBING PLAN

P221 TOWER LEVEL 12 - CONSOLE ACCESS LEVEL PLUMBING PLAN

P223 TOWER LEVEL 13 - CAB LEVEL PLUMBING PLAN

P224 TOWER ROOF PLUMBING PLAN

P301 ENLARGED PLUMBING PLANS I

P302 ENLARGED PLUMBING PLANS II

P303 ENLARGED PLUMBING PLANS III

P401 PLUMBING DIAGRAMS - WASTE & VENT

P402 PLUMBING DIAGRAMS - WASTE & VENT

P403 PLUMBING DIAGRAMS - DOMESTIC WATER

P404 PLUMBING DIAGRAMS - STORM

P501 PLUMBING DETAILS

P502 PLUMBING DETAILS

P503 PLUMBING DETAILS

P601 PLUMBING SCHEDULES I

P602 PLUMBING SCHEDULES II

P603 PLUMBING SCHEDULES III

P701 WATER SERVICE RISER ISOMETRIC

SEE G025 FOR SCHEDULE CONTINUATION

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

BRINE RETURN

LOW TEMP CHILLED WATER RETURN - GLYCOL

BRINE SUPPLY

VENTILATION (HVAC)

BOILER BLOWDOWNBBD

PIPING SYSTEMS (HVAC)

BOILER FEED WATERBFW

BR

BS

LCWR(G)

LOW TEMP CHILLED WATER SUPPLY - GLYCOLLCWS(G)

FUEL OIL RETURNFOR

FUEL OIL SUPPLYFOS

FUEL OIL VENTFOV

SNOW MELT HEATING WATER RETURN - GLYCOLSMHWR(G)

SNOW MELT HEATING WATER SUPPLY - GLYCOLSMHWS(G)

NATURAL GASG

2-WAY

2-WAY

3-WAY

3-WAY

TWO-WAY ELECTRIC CONTROL VALVE, BUTTERFLY TYPE

THREE-WAY ELECTRIC CONTROL VALVE, BUTTERFLY TYPE

SUCTION DIFFUSER

CO

REAL OBJECT SYMBOL

PIPING COMPONENTS

SIGHT FLOW GLASS

ANCHOR

CONCENTRIC REDUCER

ECCENTRIC REDUCER

AUTOMATIC AIR VENT

MANUAL AIR VENT

BALANCING VALVE

CHECK VALVE (GENERIC)

FLOAT OPERATED VALVE ACTUATOR

ANGLE VALVE

SAFETY OR RELIEF VALVE

FLEXIBLE CONNECTOR

FLANGED CONNECTION

UNION CONNECTION

EXPANSION JOINT

SHOCK ABSORBER

PRESSURE GAUGE

TEMPERATURE GAUGE

Y STRAINER (GENERIC)

Y STRAINER W/ DRAIN VALVE

GUIDE

NEEDLE VALVE

TEMPERATURE AND PRESSURE TAP

GATE VALVE

GLOBE VALVE

PRESSURE REDUCING VALVE

BALL VALVE

PLUG VALVE

BUTTERFLY VALVE NPS 6 AND LESS

BACKFLOW PREVENTER (GENERIC)

PIPE CAP

PIPE BREAK

FLOW ARROW

PIPING ELBOW DOWN

PIPING ELBOW UP

PIPING TEE UP

PIPING TEE DOWN

STANDARD CLEAN-OUT IN LINE END OF RUNCO

PIPING SLOPE

1%

CO

CO

STANDARD CLEAN-OUT THROUGH FLOOR END OF RUN

STANDARD CLEAN-OUT THROUGH FLOOR IN LINE

PUMP (GENERIC)

ISOLATION VALVE (GENERIC)

FLOW LIMITING VALVE

VACUUM BREAKER

MULTI-PURPOSE VALVE (SHUTOFF, BALANCING AND CHECK)

2-WAY CONTROL VALVE (GENERIC)

3-WAY CONTROL VALVE (GENERIC)

SOLENOID 2-WAY CONTROL VALVE

SOLENOID 3-WAY CONTROL VALVE

PIPE CROSS

BOILER STOP AND CHECK VALVE

BFP

BUTTERFLY VALVE NPS 8 AND MORE

CO

NATURAL GAS VENTGV

RECTANGULAR DUCT WITH ACOUSTIC LINING*

AIR FLOW ARROW

EXTERIOR DUCT TREATMENT*

FLEXIBLE DUCT

ELBOW TURN, SUPPLY DOWN. APPLIES TO RECT., ROUND AND OVAL

18"x12"

18"x12"

18"x12"

RECTANGULAR DUCT AND SIZE*

18"ø ROUND DUCT AND SIZE*

18"x12"

18"x12"

18"ø

18"x12"ø FLAT OVAL DUCT AND SIZE*18"x12"ø

DUCT SECTION, SUPPLY AIR. SIZE* IS HORIZONTAL DIM. x VERTICAL DIM.

APPLIES TO RECT., ROUND AND OVAL

30"x12"

DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, RETURN AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, EXHAUST AIR. APPLIES TO RECT., ROUND AND OVAL

ELBOW TURN, OUTSIDE AIR DOWN. APPLIES TO RECT., ROUND AND OVAL

ELBOW TURN, RETURN DOWN. APPLIES TO RECT., ROUND AND OVAL

ELBOW TURN, EXHAUST DOWN. APPLIES TO RECT., ROUND AND OVAL

CHANGE IN DUCT ELEVATION RISING IN DIRECTION INDICATED

CHANGE IN DUCT ELEVATION DROPPING IN DIRECTION INDICATED

END CAP

UP

DN

ELBOW, RECTANGULAR, SMOOTH RADIUS WITH SPLITTER VANES

(0.25 R/W DEFAULT)

ELBOW, RECTANGULAR, SMOOTH RADIUS WITHOUT VANES (1.5 R/W

DEFAULT)

ELBOW, ROUND, SMOOTH RADIUS (1.5 R/W DEFAULT)

MITERED ELBOW, RECTANGULAR, WITH TURNING VANES

RECTANGULAR TO ROUND TRANSITION

DUCT ACCESS DOOR (TOP, SIDE, BOTTOM)

AD

AD AD

FLEXIBLE CONNECTION

FC

BDD

BACKDRAFT DAMPER

MANUAL DAMPER

MOTORIZED DAMPER

FIRE DAMPER

SMOKE DAMPER

SMOKE AND FIRE DAMPER

DUCT SILENCER

CONTROL DEVICE (REFER TO CONTROLS LEGEND)

AIR FLOW MEASURING STATION (REFER TO CONTROLS LEGEND)

AIR OUTLET OR INLET TAG (REFER TO SCHEDULE)

RECTANGULAR DIFFUSER, SUPPLY. OPTIONAL ARROWS SHOW THE

FLOW DIRECTION.

RECTANGULAR REGISTER OR GRILLE, RETURN

RECTANGULAR REGISTER OR GRILLE, EXHAUST

ROUND DIFFUSER, SUPPLY

LINEAR DIFFUSER

SIDEWALL REGISTER OR GRILLE, SUPPLY

SIDEWALL GRILLE, RETURN OR EXHAUST

UNDERCUT DOOR

DOOR GRILLE OR LOUVER

TRANSFER GRILLE OR LOUVER

COIL (REFER TO CONTROLS LEGEND)

EQUIPMENT TAG

RADIATION HEATING TAG (REFER TO SCHEDULE)

M

X

ID-#

QUANTITY

TYPE

SIZE (IN.)

VOLUME (CFM)

VENTILATION (HVAC)

QUANTITY

TYPE

LENGTH (FT)

CAPACITY (MBH)

UC

PIPE INSULATION

2 1/2" PIPE SIZE

* NOTE: ALL DUCT SIZES ARE INTERIOR, FREE DIMENSIONS (ALWAYS

WIDTH X HEIGHT IN FLOOR PLAN AND SECTION)

ONE-LINE DIAGRAMS - DUCTWORK

SUPPLY AIR (SA)

RETURN AIR (RA)

EXHAUST AIR (EA)

OUTSIDE AIR (OA)

HOSE BIBB

DRAIN VALVE

6-WAY VALVEM

UNDERLAY ELEMENTS SHOWN BELOW LEVEL

MEDIUM TEMP CHILLED WATER RETURN - GLYCOLMCWR(G)

MEDIUM TEMP CHILLED WATER SUPPLY - GLYCOLMCWS(G)

HEATING WATER RETURN - GLYCOLHWR(G)

HEATING WATER SUPPLY - GLYCOLHWS(G)

HIGH PRESSURE HEATING WATER RETURN - GLYCOLHPHWR(G)

HIGH PRESSURE HEATING WATER SUPPLY - GLYCOLHPHWS(G)

HIGH PRESSURE LOW TEMP CHILLED WATER RETURN - GLYCOLHPLCWR(G)

HIGH PRESSURE LOW TEMP CHILLED WATER SUPPLY - GLYCOLHPLCWS(G)

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

06/11/2024

/1

/2

: 5 :4

P

M

M002

MECHANICAL LEGENDS & ABBREVIATIONS & SHEET

INDEX

MSM

KMS

SS

6/11/2024

S u b m itt a l P h a s e

MECHANICAL

A/C AIR CONDITIONING UNIT

AAV AUTOMATIC AIR VENT

ACS AIR CLEANING SYSTEM

ADA AMERICANS WITH DISABILITIES ACT

ADJ ADJUSTABLE

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AP ACCESS PANEL

APD AIR PRESSURE DROP

AVG AVERAGE

BAS BUILDING AUTOMATION SYSTEM

BDD BACKDRAFT DAMPER

BHP BRAKE HORSEPOWER

BMS BUILDING MANAGEMENT SYSTEM

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

C/W COMPLETE WITH

CAV CONSTANT AIR VOLUME

CB CHILLED BEAM

CFM CUBIC FEET PER MINUTE

COTF CLEANOUT THROUGH FLOOR

DB DRY BULB TEMPERATURE

dB DECIBEL(S)

DDC DIRECT DIGITAL CONTROL

DEG DEGREE

DIA./Ø DIAMETER

DIFF DIFFERENTIAL

DIV DIVISION

DN DOWN

DOAS DEDICATED OUTSIDE AIR SYSTEM

DWG DRAWING

EA EXHAUST AIR

EA (D) EXHAUST AIR, DISHWASH

EA (G) EXHAUST AIR, GENERAL

EA (K) EXHAUST AIR, KITCHEN

EA (LAB) EXHAUST AIR, LABORATORY

EA (LD) EXHAUST AIR, LAUNDRY/DRYER

EA (W) EXHAUST AIR, WASHROOM

EAT ENTERING AIR TEMPERATURE

EAV EXHAUST AIR VALVE

ED EXISTING TO BE DEMOLISHED (DEMOLITION

PLANS)

EER ENERGY EFFICIENCY RATIO

EM EMERGENCY

ER EXISTING RELOCATED (NEW CONSTRUCTION

PLANS)

ERL EXISTING TO BE RELOCATED (DEMOLITION

PLANS)

ESP EXTERNAL STATIC PRESSURE

EWT ENTERING WATER TEMPERATURE

FFCU FLOOR FAN COIL UNIT

FLA FULL LOAD AMPERAGE

FO FUEL OIL

FP FIRE PROTECTION

FPM FEET PER MINUTE

FPS FEET PER SECOND

FT FOOT/FEET

GA GAUGE

GAL GALLON (US)

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HFCU HORIZONTAL FAN COIL UNIT

HP HORSEPOWER

HR HOUR

HVAC HEATING / VENTILATING / AIR CONDITIONING

HZ HERTZ

IE INVERT ELEVATION

IN INCHES

IN WG INCHES WATER GAUGE

IPLV INTEGRATED PART LOAD VALUE

kW KILOWATT kWh KILOWATT HOUR

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LF LINEAR FEET

LWT LEAVING WATER TEMPERATURE

M METER

MAX MAXIMUM

MBH THOUSAND OF BTUH

MCA MINIMUM CIRCUIT AMPS

MFR MANUFACTURER

MIN MINIMUM

MOP MAXIMUM OVERCURRENT PROTECTION

MQ MOTORIZED QUADRANT

N/A NOT APPLICABLE

NB NOT BALANCED

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NPS NOMINAL PIPE SIZE

NTS NOT TO SCALE

OA OUTSIDE AIR

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFE OWNER FURNISHED EQUIPMENT

OFOI OWNER FURNISHED / OWNER INSTALLED

PG PROPYLENE GLYCOL

POE POINT OF ENTRANCE

POS POINT OF SERVICE

PPM PARTS PER MILLION

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH, ABSOLUTE

PSIG POUNDS PER SQUARE INCH, GAGE

PTS PNEUMATIC TUBE STATION

PVC POLYVINYL CHLORIDE

RA RETURN AIR

RELA RELIEF AIR

REQD REQUIRED

RH RELATIVE HUMIDITY

RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR

SP STATIC PRESSURE

SP STAIR PRESSURIZATION AIR (*)

SRV SAFETY RELIEF VALVE

TA TRANSFER AIR

TEMP TEMPERATURE

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

TYP TYPICAL

UC UNDER CUT (DOOR)

UG UNDERGROUND

UP UP

VAV VARIABLE AIR VOLUME

VFD VARIABLE FREQUENCY DRIVE

VIF VERIFY IN FIELD

VTR VENT-THRU-ROOF

W/ WITH

W/O WITHOUT

WB WET BULB TEMPERATURE

WG WATER GAUGE

YCO YARD CLEANOUT

ZN-# ZONE

°C CELSIUS

°F FAHRENHEIT

Ø PHASE

SHEET INDEX - MECHANICAL

# NAME

M002 MECHANICAL LEGENDS & ABBREVIATIONS & SHEET INDEX

M201 OVERALL LEVEL 1 MECHANICAL PLAN

M202 BASE BUILDING LEVEL 1 MECHANICAL PLAN - AREA A

M203 BASE BUILDING & TOWER LEVEL 1 MECHANICAL PLAN - AREA B

M204 OVERALL LEVEL 2 MECHANICAL PLAN

M205 BASE BUILDING LEVEL 2 MECHANICAL PLAN - AREA A

M206 BASE BUILDING & TOWER LEVEL 2 MECHANICAL PLAN - AREA B

M207 BASE BUILDING OVERALL ROOF MECHANICAL PLAN

M208 TOWER LEVEL 1 & 2 - MECHANICAL PLAN

M209 TOWER LEVEL 3 & 3B - STAIR 1 FAN LEVEL MECHANICAL PLAN

M210 TOWER LEVEL 4 & 4B - STAIR 2 FAN LEVEL MECHANICAL PLAN

M211 TOWER LEVEL 5 - MECHANICAL PLAN

M212 TOWER LEVEL 6 & 6B - STAIR 1 FAN LEVEL MECHANICAL PLAN

M213 TOWER LEVEL 7 & 7B - STAIR 2 FAN LEVEL MECHANICAL PLAN

M214 TOWER LEVEL 8 - MECHANICAL PLAN

M215 TOWER LEVEL 9 - ELECTRICAL LEVEL MECHANICAL PLAN

M216 TOWER LEVEL 10 - ELECTRONICS LEVEL MECHANICAL PLAN

M217 TOWER LEVEL 11 - JUNCTION LEVEL MECHANICAL PLAN

M218 TOWER LEVEL 12 - CONSOLE ACCESS LEVEL MECHANICAL PLAN

M219 TOWER LEVEL 13 - CAB LEVEL MECHANICAL PLAN

M300 MECHANICAL SITE PLAN

M301 OVERALL LEVEL 1 PIPING PLAN

M302 BASE BUILDING LEVEL 1 PIPING PLAN - AREA A

M303 BASE BUILDING & TOWER LEVEL 1 PIPING PLAN - AREA B

M304 OVERALL LEVEL 2 PIPING PLAN

M305 BASE BUILDING LEVEL 2 PIPING PLAN - AREA A

M306 BASE BUILDING & TOWER LEVEL 2 PIPING PLAN - AREA B

M307 BASE BUILDING OVERALL ROOF PIPING PLAN

M308 TOWER LEVEL 1 & 2 - PIPING PLAN

M309 TOWER LEVEL 3 & 3B - STAIR 1 FAN LEVEL PIPING PLAN

M310 TOWER LEVEL 4 & 4B - STAIR 2 FAN LEVEL PIPING PLAN

M311 TOWER LEVEL 5 - PIPING PLAN

M312 TOWER LEVEL 6 & 6B - STAIR 1 FAN LEVEL PIPING PLAN

M313 TOWER LEVEL 7 & 7B - STAIR 2 FAN LEVEL PIPING PLAN

M314 TOWER LEVEL 8 - PIPING PLAN

M315 TOWER LEVEL 9 - ELECTRICAL LEVEL PIPING PLAN

M316 TOWER LEVEL 10 - ELECTRONICS LEVEL PIPING PLAN

M317 TOWER LEVEL 11 - JUNCTION LEVEL PIPING PLAN

M318 TOWER LEVEL 12 - CONSOLE ACCESS LEVEL PIPING PLAN

M400 MECHANICAL SECTIONS

M401 MECHANICAL SECTIONS

M402 MECHANICAL SECTIONS

M403 MECHANICAL SECTIONS

M404 MECHANICAL SECTIONS-BOILER RM

M405 MECHANICAL SECTIONS-ELECTRONIC EQUIPMENT RM

M406 MECHANICAL SECTIONS-ELECTRONIC EQUIPMENT RM II

M410 ENLARGED MECHANICAL PLANS

M420 ENLARGED PIPING PLANS I

M421 ENLARGED PLANS I CLEARANCES

M422 ENLARGED PIPING PLANS II

M601 MECHANICAL DIAGRAMS - PIPING

M602 MECHANICAL DIAGRAMS - AIR RISER

M603 MECHANICAL DIAGRAMS - HEATING & COOLING PLANT

M701 MECHANICAL SCHEDULES

M702 MECHANICAL SCHEDULES

M703 MECHANICAL SCHEDULES

M704 MECHANICAL SCHEDULES

M705 MECHANICAL SCHEDULES

M706 MECHANICAL SCHEDULES

M801 MECHANICAL DETAILS

M802 MECHANICAL DETAILS

M803 MECHANICAL DETAILS

M804 MECHANICAL DETAILS

M805 MECHANICAL DETAILS

M901 MECHANICAL CONTROLS LEGEND AND ABBREVIATIONS

M902 ERV CONTROLS

M903 FAN COIL AND CHILLED BEAM CONTROLS

M904 AHU AND VAV WITH HEATING COIL CONTROLS

M905 STAIR PRESSURIZATION AND VENT FAN CONTROLS

M906 MISCELLANEAOUS MECHANICAL CONTROLS

M907 CHILLER-HEATING PLANT CONTROLS DIAGRAM

M908 CHILLER-HEATING PLANT SEQUENCE OF OPERATIONS

M909 SNOW MELT SEQUENCE OF OPERATIONS

M910 AC UNIT, METERS, AND HEAT TRACE CONTROLS

M911 GENERATOR VENTILATION AND LOAD SHEDDING CONTROLS

M912 UPS VENTILATION CONTROL

MECHANICAL ABBREVIATIONS

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

CG

T

MS

MS

MS

MS

MS

T

T

T

T

MS

T

MS

TT

T

M

M

M M

T

MS MS

M

M

M MM MM

M

M

M

M

M

M

MM

M

T

T T

T

T

T

MS

MS

MS

T TR

RT

M

M

T

T

T

T

TA

TC

T3

T1

T2

TB

J

1 5

A

C

E

G

K

B

D

F

ELECTRICAL

GENERATOR

PARTS STOR

SECURE STOR

ARCTIC ENTRY

MECHANICAL RM

STAIR 4

ST4-1

CPDS-1 SYST SPECIALS

131A

LOADING/ VEHICLE STOR

LAN-1

PPE STOR GROUP

PPE STOR TECH

127A

WOMEN'S RESTROOM

MEN'S RESTROOM

LINK 1

SECURITY EQUIP

JANITOR

RECEPTION

STAIR 5

ST5-1

SHIP/ RECEIVE

HALL-SOUTH

127S

STORAGE

GMM

135A

UPS

STAIR 1

ST1-1

STAIR 2

ST2-1

PLUMB CHASE

ELECT CHASE

FIRE PUMP

FIRE CONTROL

ELEV LOBBY

ELEV 4 CONTROL

SMOKING

AT SYSTEM SPECS

131B

SSC COORD

TECH OPS SSC MAN.

SSC ADMIN SUPP

BOILER RM

TECH OPS CONF

TELCO-PPO

DDC CONTROL

FLS ELECT

OPEN OFFICE

ELECTRICAL

ENVIRONMENTAL SHOP

M400

A8_______

MATCHLINE A8/ M202

MATCHLINE A8/ M203

"x

O A

"x

E A

108"x36" OA

"x

F

LU

E

"x

O A

"x

O A

B-AHU-5

B-ERV-3

6" ø

S A

B-VAV3-4

B-VAV3-3

B-VF-1

B-EF-4

B-VAV3-1

MATCHLINE A8/ M202

MATCHLINE A8/ M203

M401

C3_______

M403

D8_______

M403

D6_______

M403

D4_______

M403

D5_______

M403

D2_______

9'-7 5/8" 10'-0 3/4"

SHEET NOTES - MECHANICAL

1. EXACT LOCATIONS OF ALL WALL MOUNTED SENSORS, LOUVERS, CEILING DIFFUSERS, REGISTERS

AND GRILLES, AND ACTIVE CHILLED BEAMS ARE DETAILED ON THE ARCHITECTURAL REFLECTED

CEILING PLANS AND INTERIOR ELEVATIONS.

2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST TO THE GOVERNMENT.

3. EXACT LOCATION OF ALL ROOF AND FLOOR OPENINGS TO BE COORDINATED WITH CONSTRUCTION

WORK AND ARCHITECTURAL AND STRUCTURAL DRAWINGS.

4. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS,

DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

5. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE

BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED.

6. PROVIDE FIRE DAMPERS AS SHOWN ON DRAWINGS AT ALL PENETRATIONS THROUGH FIRE RATED

WALLS AND FLOOR/CEILING. DAMPERS SHALL BE INSTALLED STRICTLY PER MANUFACTURERS

INSTRUCTIONS AND THE DAMPER'S LISTING.

7. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL

REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA)

8. DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS, INTERNAL DUCT LINER AND

EXTERNAL INSULATION ARE IN ADDITION TO THE DIMENSIONS SHOWN.

9. PENETRATION OF RATED ASSEMBLIES SHALL BE FIRE STOPPED USING AN APPROVED PENETRATION FIRESTOP AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE AN F AND T RATING OF NOT

LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLIES.

10. ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THE PLANS, IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR

THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) NATIONAL STANDARDS.

11. ALL OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL INCORPORATE DAMPERS THAT

AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE. THE DAMPERS SHALL BE EITHER

MOTORIZED OR OF THE GRAVITY TYPE.

12. PROVIDE INSULATED DOUBLE WALL DUCTWORK AT ALL EXPOSED AREAS AND FROM ALL AIR

HANDLING UNITS THROUGH THE FIRST 15 FEET LENGTH OF SUPPLY DUCTS.

13. SEE ARCHITECTURAL FOR LOUVERS AND SCHEDULES.

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

0'8' 8' 24'16'

SCALE: 3/32" = 1'-0"

TRUENORTH

KEY PLAN

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

06/11/2024

/1

/2

: 5 :5

P

M

M201

OVERALL LEVEL 1 MECHANICAL PLAN

MSM

TR

SS

6/11/2024

S u b m itt a l P h a s e

MECHANICAL

3/32" = 1'-0"M201

A8 LEVEL 1 OVERALL MECHANICAL PLAN

KEYNOTES

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

CG

T

MS

MS

MS

MS

T

M

M MM MM

M

M

M

M

M

M

MM

T

T T

T

T

T

M

T

J

1 5432

E

G

K

F

MATCHLINE A8/ M203

ELECTRICAL

GENERATOR

PARTS STOR

ENVIRONMENTAL SHOP

STAIR 4

ST4-1

LOADING/ VEHICLE STOR

PPE STOR TECH

127A

SECURITY EQUIP

STORAGE

FLS ELECT

11316"x16" EA

16"x16" SA

"x

O A 16

"x

E

A

"ø

R A

PPE STOR GROUP

SECURE STOR

GMM

135A

B-VAV5-4

"x

S A

B-VAV3-5

TELCO-PPO

LAN-1

8" ø

S A

"ø

S A

6"ø

CB-3B

6"ø

CB-2E

15 8"ø

CB-6A

M:01

24"ø RA

B-VAV5-6

14"ø FLUE UP

B-VAV1-1

B-VAV1-2

8"ø SA

6"ø RA

6"ø SA

8"ø SA

6"ø SA

ELEV 3 CAB

E3

8" ø

S A

6"ø SA

12"x12" S-4

12"x12"

S-4

12"x12"

S-4

FLEXIBLE

CONNECTION

40"Wx28"Hx27"L

SUMMER MERV

9 & MERV-15

FILTER BOX

B-PHC-3

B-ERV-3

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

44"x60"

MOTORIZED

RECIRCULATION

DAMPER (TYP 6)

8"x8" S-4

8"x8" S-4

8"x8" S-4

8"x8" S-4

8"x8" S-4

8"x8" S-4

8"x8" S-4

"x

S A

ELECTRICAL

6"x6" S-6

6"x6" S-6

6"x6" S-6

"ø

S A

B-TCAC-1

12"x12" SA

12"x12" SA

M401

E5_______

36"x30" OA 36"x30" EA

OFFSET BRANCH DUCT

OVER MAIN

B-VAV3-66"ø SA 6"ø SA

8"ø RA

8"x6" S-3

10"x10" S-6

10"x10" SA

CONNECT TO

ARCHITECTURAL LOUVER.

24"x18" MIN. SEE

ARCHITECTURAL PLANS,

TYP.

10"x12"

T-1

16"x16"

T-1

14"ø EA

M401

C3_______

8"x8" S-6

8"x6" S-6

16"x16" SA

VOLUME

DAMPER (TYP)

28"x20"

R-4

8"x8" R-3

6"x6" R-3

6"x6" R-3

8"x8" R-3

8"ø RA

M403

D8_______

12"x10"

R-3

32"x30"

R-4

M403

D2_______

14"x22"

T-1 20"x12" RA

MD-1-1

MD-1-2 MD-1-3

MD-1-4

6"ø SA

8" ø

E A

MD-1-7

MD-1-8

6"ø SA

10"x10"

R-4

EXHAUST

SILENCER,

SEE 26 32 13

M804

E2 TYP

M804

E4 TYP

MQ-1-1

MQ-2-1

12"x12" SA

M402

E8_______

DUCT ACCESS

DOOR

M402

B8_______

3FT MIN

SHEET NOTES - MECHANICAL

1. EXACT LOCATIONS OF ALL WALL MOUNTED SENSORS, LOUVERS, CEILING DIFFUSERS, REGISTERS

AND GRILLES, AND ACTIVE CHILLED BEAMS ARE DETAILED ON THE ARCHITECTURAL REFLECTED

CEILING PLANS AND INTERIOR ELEVATIONS.

2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST TO THE GOVERNMENT.

3. EXACT LOCATION OF ALL ROOF AND FLOOR OPENINGS TO BE COORDINATED WITH CONSTRUCTION

WORK AND ARCHITECTURAL AND STRUCTURAL DRAWINGS.

4. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS,

DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

5. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE

BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED.

6. PROVIDE FIRE DAMPERS AS SHOWN ON DRAWINGS AT ALL PENETRATIONS THROUGH FIRE RATED

WALLS AND FLOOR/CEILING. DAMPERS SHALL BE INSTALLED STRICTLY PER MANUFACTURERS

INSTRUCTIONS AND THE DAMPER'S LISTING.

7. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL

REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA)

8. DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS, INTERNAL DUCT LINER AND

EXTERNAL INSULATION ARE IN ADDITION TO THE DIMENSIONS SHOWN.

9. PENETRATION OF RATED ASSEMBLIES SHALL BE FIRE STOPPED USING AN APPROVED PENETRATION FIRESTOP AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE AN F AND T RATING OF NOT

LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLIES.

10. ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THE PLANS, IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR

THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) NATIONAL STANDARDS.

11. ALL OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL INCORPORATE DAMPERS THAT

AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE. THE DAMPERS SHALL BE EITHER

MOTORIZED OR OF THE GRAVITY TYPE.

12. PROVIDE INSULATED DOUBLE WALL DUCTWORK AT ALL EXPOSED AREAS AND FROM ALL AIR

HANDLING UNITS THROUGH THE FIRST 15 FEET LENGTH OF SUPPLY DUCTS.

13. SEE ARCHITECTURAL FOR LOUVERS AND SCHEDULES.

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

0'8' 16'8'

SCALE: 1/8" = 1'-0"

TRUENORTH

KEY PLAN

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

06/11/2024

/1

/2

: 5 :0

P

M

M202

BASE BUILDING LEVEL 1 MECHANICAL PLAN - AREA

A

MSM

TR

SS

6/11/2024

S u b m itt a l P h a s e

MECHANICAL

1/8" = 1'-0"M202

A8 LEVEL 1 MECHANICAL PLAN - AREA A

KEYNOTES

M:01 PROVIDE HEAT TRACE ON STRUCTURAL CROSS BEAM.

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

MS

MS

T

T

T

T

MS

T

MS

TT

M

M

M

M

T

MS MS

M

M

MS

MS

MS

T TR

R T

M

T

T

T

TA

TC

T3

T1

T2

TB

1 5

A

C

E

B

D

MATCHLINE A8/ M202

M208

ELECTRICAL

ARCTIC ENTRY

ENVIRONMENTAL SHOP

CPDS-1 SYST SPECIALS

131A

WOMEN'S RESTROOM

MEN'S RESTROOM

LINK 1

JANITOR

RECEPTION

STAIR 5

ST5-1

SHIP/ RECEIVE

HALL-SOUTH

127S

UPS

STAIR 1

ST1-1

STAIR 2

ST2-1

PLUMB CHASE

ELECT CHASE

FIRE PUMP

FIRE CONTROL

ELEV LOBBY

ELEV 4 CONTROL

SMOKING

AT SYSTEM SPECS

131B

SSC COORD

TECH OPS SSC MAN.

SSC ADMIN SUPP

BOILER RM

DDC CONTROL

OPEN OFFICE

M400

A8_______

"ø

R A

B-VAV3-25

22"x14"

T-2

22"x14"

T-2

18"x10" TA

B-VAV3-5

B-VAV3-1MECHANICAL RM

TECH OPS CONF

108"x20" 16"ø FLUE UP

8" ø

S A

ELEV 4 CAB

E4

6"ø

CB-2E

15 8"ø

CB-6A

4"ø

CB-2F

4"ø

CB-2A

4"ø

CB-2A

4" ø

S A

4" ø

S A

6"ø SA

6"ø SA

B-VAV3-4

6"ø SA

6"ø

CB-5A

6"ø SA

"ø

R A

10"ø SA 6"ø SA

4"ø S-5

6"ø RA

8"ø

CB-7A

6"ø

CB-3B

4"ø S-5

8"ø SA

6" ø

S A14"ø SA 14"ø RA

10"ø EA

8"ø EA

8" ø

E A

8"ø E-1

6"ø RA

4" ø

S A

14"ø RA

8"ø SA

B-VAV1-1

B-VAV1-2

8"ø SA

16"ø S-11

8"ø E-1

10"ø R-1

6"ø R-1

6"ø R-1

6"ø S-1

8"ø R-1

6"ø EA

B-VAV3-2

6"ø S-1

B-VAV5-1

12"ø S-2

12"ø SA

HALL-WEST

127W

6"ø

CB-3D

6"ø

CB-3D

6"ø

CB-5A

12"ø R-1

10"ø SA

6"ø SA

8"ø SA

6"ø SA

8"ø SA

6" ø

S A

4" ø

S A

4" ø

S A

6"ø SA

B-VAV3-7

"ø

S A

B-VAV3-3

B-VAV5-5

RELIEF

"x

R A

B-EF-4

12"ø RA

B-AHU-5

12"ø E-1

"x

O A

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

48x24 EA CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

"x

S A

8"x8" S-4

8"x8" S-4

"x

S A

B-EF-2

12"x12"

R-1

53"x14" RA

6"x6" E-2

6"ø R-1

"ø

S A

BELOW 18"ø SA 10"ø SA

M401

A6_______

6"ø SA

B-EF-1

M401

A8_______

MD-1-9

6"ø SA 8"ø SA

6"ø R-1

B-AC-1

B-VF-1

12"x12" S-3

14"x14" S-3

"x

O A

"x

E A

CONNECT TO

ARCHITECTURAL LOUVER.

SEE ARCHITECTURAL

PLANS, TYP.

48"x36"

R-1

B-FCU-3-B

B-VAV5-2

10"ø SA

"ø

S A

8" ø

S A

14"ø EA

6"x6" R-3

8"x8" T-2

8"ø RA

M403

D6_______

M403

D4_______

M403

D5_______

4"ø

CB-3A

12"x12" S-6

12"x12" S-6

22"x14"

T-1

14"x22"

T-1

14"x22"

T-1

20"x12" RA

MD-1-11 MD-1-12

MD-1-14

MD-1-15

24"x16" SA

18"x18" EA

B-S A-S

A5

"ø

S A

22"x12" R-2

10"ø

S-10

6"ø SA

10"x10"

R-4

E4

TYP

FAN GUARD

ON INLET

14"x14" SA

6"ø SA

10"ø RA

"ø

R A

18"x16" RA

18"x18" E-2

"ø

R A

12"x12" RA

8"ø EA

VOLUME DAMPER

ON BRANCH

14"ø EA UP

12"ø RA

B-VAV3-26

"ø

E A

B-FCU-5-C

11'-3 1/4"

32"x32" SA

B-VAV-5-3

B-FCU-5-B

SHEET NOTES - MECHANICAL

1. EXACT LOCATIONS OF ALL WALL MOUNTED SENSORS, LOUVERS, CEILING DIFFUSERS, REGISTERS

AND GRILLES, AND ACTIVE CHILLED BEAMS ARE DETAILED ON THE ARCHITECTURAL REFLECTED

CEILING PLANS AND INTERIOR ELEVATIONS.

2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST TO THE GOVERNMENT.

3. EXACT LOCATION OF ALL ROOF AND FLOOR OPENINGS TO BE COORDINATED WITH CONSTRUCTION

WORK AND ARCHITECTURAL AND STRUCTURAL DRAWINGS.

4. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS,

DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

5. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE

BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED.

6. PROVIDE FIRE DAMPERS AS SHOWN ON DRAWINGS AT ALL PENETRATIONS THROUGH FIRE RATED

WALLS AND FLOOR/CEILING. DAMPERS SHALL BE INSTALLED STRICTLY PER MANUFACTURERS

INSTRUCTIONS AND THE DAMPER'S LISTING.

7. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL

REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA)

8. DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS, INTERNAL DUCT LINER AND

EXTERNAL INSULATION ARE IN ADDITION TO THE DIMENSIONS SHOWN.

9. PENETRATION OF RATED ASSEMBLIES SHALL BE FIRE STOPPED USING AN APPROVED PENETRATION FIRESTOP AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE AN F AND T RATING OF NOT

LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLIES.

10. ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THE PLANS, IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR

THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) NATIONAL STANDARDS.

11. ALL OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL INCORPORATE DAMPERS THAT

AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE. THE DAMPERS SHALL BE EITHER

MOTORIZED OR OF THE GRAVITY TYPE.

12. PROVIDE INSULATED DOUBLE WALL DUCTWORK AT ALL EXPOSED AREAS AND FROM ALL AIR

HANDLING UNITS THROUGH THE FIRST 15 FEET LENGTH OF SUPPLY DUCTS.

13. SEE ARCHITECTURAL FOR LOUVERS AND SCHEDULES.

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

0'8' 16'8'

SCALE: 1/8" = 1'-0"

TRUENORTH

KEY PLANKEY PLAN

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

06/11/2024

/1

/2

: 5 :2

P

M

M203

BASE BUILDING & TOWER LEVEL 1 MECHANICAL

PLAN - AREA B

MSM

TR

SS

6/11/2024

S u b m itt a l P h a s e

MECHANICAL

1/8" = 1'-0"M203

A8 LEVEL 1 MECHANICAL PLAN - AREA B

KEYNOTES

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

MS MS MS

MS

MS

MS

MS

MS

MS

MS

T

MS

MS

MS

T

MS

T

MS

MS

MS

MS

T

T

T

T

T

MS

MS

MS

MS

MS

MS

MS MS

MS

MS

MS

MS

MS

MSMS

MS

MS

MS

MS

MS

T

T

T

T

MS

TA

TC

T3

T1

T2

TB

J

1 5

A

C

E

G

K

B

D

F

ELEV LOBBY

STAIR 2

ST2-2

STAIR 1

ST1-2

STAIR 4

ST4-2

LARGE CONF

QUIET RM

ADMIN STOR

MAIL-FILE-COPIER

PLUMB CHASE

ELECT CHASE

TRACON SUPP SPECS

228B

TRACON ADMIN SUPP

WOMEN'S RESTROOM

MEN'S RESTROOM

JANITOR

LOCKERS

CBI TRAIN

208UNISEX TOILET/SHOWER

UNISEX TLT/SHWR/TEST

TRACON

ELECTRONIC EQUIP

AT COACH

VESTIBULE

ACCESS AISLE

LAN-2

ACCESS AISLE

TRACON OPS SUP

SMALL CONF

TRACON OPS SUP

TRACON OPS SUP

TRACON OPS SUP

CWO

ATCT OPS SUP

ATCT OPS SUP

TRAIN CONTRACT

227C

TRAIN CONTRACT

227C

TRAIN PROGRAM

227A

TSS PRE/DEBRIEF

PLAYBACK

TRACON ATM

STAFF SSA-QC

228A

ATCT SUPP SPEC

228D

STAFF SSA-TRAINING

228E

TELCO-FTI

NAS ELECTRONIC WORKSHOP

NAS TECH LIBRARY

231A

KITCHEN

BREAKROOM

TURNAGAIN SSC ATSS

LACTATION

STAIR 5

ST5-2

ATCT OPS SUP

ATCT OPS SUP

ATCT ATM

STAFF SSA-AIRSPACE

228C

LAN-2

STARS SUPP SPEC

TSS

ATCT ADMIN SUPP

204A

LINK 2

HALL-SOUTH

248S

TSS CLASSROOM

MATCHLINE A8/ M205

MATCHLINE A8/ M206

M401

C3_______

M406

E8_______

M403

D8_______

M403

D6_______

M403

D4_______

M403

D5_______

M403

D2_______

SHEET NOTES - MECHANICAL

1. EXACT LOCATIONS OF ALL WALL MOUNTED SENSORS, LOUVERS, CEILING DIFFUSERS, REGISTERS

AND GRILLES, AND ACTIVE CHILLED BEAMS ARE DETAILED ON THE ARCHITECTURAL REFLECTED

CEILING PLANS AND INTERIOR ELEVATIONS.

2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST TO THE GOVERNMENT.

3. EXACT LOCATION OF ALL ROOF AND FLOOR OPENINGS TO BE COORDINATED WITH CONSTRUCTION

WORK AND ARCHITECTURAL AND STRUCTURAL DRAWINGS.

4. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS,

DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

5. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE

BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED.

6. PROVIDE FIRE DAMPERS AS SHOWN ON DRAWINGS AT ALL PENETRATIONS THROUGH FIRE RATED

WALLS AND FLOOR/CEILING. DAMPERS SHALL BE INSTALLED STRICTLY PER MANUFACTURERS

INSTRUCTIONS AND THE DAMPER'S LISTING.

7. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL

REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA)

8. DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS, INTERNAL DUCT LINER AND

EXTERNAL INSULATION ARE IN ADDITION TO THE DIMENSIONS SHOWN.

9. PENETRATION OF RATED ASSEMBLIES SHALL BE FIRE STOPPED USING AN APPROVED PENETRATION FIRESTOP AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE AN F AND T RATING OF NOT

LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLIES.

10. ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THE PLANS, IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR

THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) NATIONAL STANDARDS.

11. ALL OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL INCORPORATE DAMPERS THAT

AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE. THE DAMPERS SHALL BE EITHER

MOTORIZED OR OF THE GRAVITY TYPE.

12. PROVIDE INSULATED DOUBLE WALL DUCTWORK AT ALL EXPOSED AREAS AND FROM ALL AIR

HANDLING UNITS THROUGH THE FIRST 15 FEET LENGTH OF SUPPLY DUCTS.

13. SEE ARCHITECTURAL FOR LOUVERS AND SCHEDULES.

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

0'8' 8' 24'16'

SCALE: 3/32" = 1'-0"

TRUENORTH

KEY PLAN

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

06/11/2024

/1

/2

: 5 :4

P

M

M204

OVERALL LEVEL 2 MECHANICAL PLAN

MSM

TR

SS

6/11/2024

S u b m itt a l P h a s e

MECHANICAL

3/32" = 1'-0"M204

A8 LEVEL 2 OVERALL MECHANICAL PLAN

KEYNOTES

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

MS MS

MS

MS

MS

MS

MS

MS

MS

MS

MS

T

T

MS

MS

MS

MS

MS

MS

MS MS

MS

T

MS

TC

J

1 5432

E

G

K

F

STAIR 4

ST4-2

TRACON SUPP SPECS

228B

TRACON ADMIN SUPP

AT COACH

ACCESS AISLE

TRACON OPS SUP

SMALL CONF

TRACON OPS SUP

TRACON OPS SUP

TRACON OPS SUP

CWO

ATCT OPS SUP

TRAIN CONTRACT

227C

TRAIN PROGRAM

227A

TSS PRE/DEBRIEF

PLAYBACK

TRACON ATM

16"x16" SA

"x

S A

"x

S A

18"x14" RA

18"x14" RA

"x

R A

36"x18" RA

16"x16" SA

"x

S A

18"x14" RA

STAFF SSA-QC

228A

ATCT SUPP SPEC

228D

STAFF SSA-TRAINING

228E

TELCO-FTI

STAFF SSA-AIRSPACE

228C

B-VAV1-8

22"x20" SA

10"ø SA

8"ø SA

32"x16" RA

TSS

6"ø

CB-4A

6"ø SA

ELEV 3 CAB

E36"ø SA

10"ø SA 6"ø SA

"ø

S A

8"ø SA

6"ø SA 6"ø SA

6"ø SA

8" ø

S A

6"ø SA

8" ø

S A

6"ø SA

8" ø

S A

6" ø

S A

6" ø

S A

6" ø

S A

6" ø

S A

"ø

S A

6"ø SA

6"ø

CB-4A

6"ø

CB-3J

6"ø

CB-2B

6"ø

CB-2B

6"ø

CB-2J

45 6"ø

CB-3G

6"ø

CB-3H

6"ø

CB-2D

6"ø

CB-2D

6"ø

CB-3F

6"ø

CB-3D

6"ø

CB-3D

LAN-2

HALL-NORTH

248N

TSS CLASSROOM

ELECTRONIC EQUIP

6"ø

CB-4A

45 8" ø

S A

12"ø SA

B-VAV-3-14

10"ø RA

15"x9" S-12

8" x8

S

A

B-VAV1-4

B-VAV1-3

"ø

R A

"x

S A

16"x14" RA

"ø

R A

"ø

S A

"x

S A

6"ø R-1

6"ø R-1

6"ø R-1

6"ø R-1

6"ø R-1

6"ø R-1

6"ø R-1

6"ø R-1

6"ø R-1

12"ø R-1

10"ø R-1

6"ø RA

6"ø RA6"ø RA6"ø RA

8"ø SA

B-VAV-3-16

12"ø RA

8"ø

CB-3A

6"ø SA

B-VAV-3-15

8"ø R-1

14"ø R-1

6"ø SA

B-VAV-3-17

10"ø S-11

B-VAV1-9

10"ø SA

"ø

S A 8"x8" SA

14"ø FLUE UP/DN

6"ø R-1

10"ø S5

14"ø R-1

"x

R A

"ø

R A

12"x12" RA

"x

S A

B-VAV-3-13

B-VAV-3-12

B-VAV-3-11

ELECTRONIC EQUIP

TELCO-FTI

EXIT CORRIDOR

248W

"ø

S A

"ø

S A

B-VAV-3-23

M405

C8_______

"x

R A

"x

R A

18"x12"

R-4

9"x12" S-12

18"x12"

R-4

9"x12" S-12

18"x12"

R-4

9"x12" S-12

18"x12"

R-4

6"ø

CB-2C

10"ø SA

8"x8" SA

18"ø RA 10 "ø

S A

8"x8" S-6

210"x10" S-4

8"x8" S-3

M406

E8_______

18"x12"

R-4

10"x10"

R-1

12"ø SA

"ø

R A

"ø

R A

"ø

R A

"ø

R A

18"ø RA 8"ø

CB-8B

6"ø SA

6"ø SA

6"ø SA

6"ø SA

6"ø

CB-3A

6"ø SA

6"ø

CB-4A

12"x12"

R-4 B-SA-RA2B

B-SA-SA1

14"x16" SA

B-SA-SA2

6"ø SA

6" ø

S A

6"ø SA

8"ø SA

21"x9" RA

22"x14"

T-1

M405

F8_______ fds

V:03

V:03

V:01

V:03

V:01

V:03

B-FCU-3-A

SHEET NOTES - MECHANICAL

1. EXACT LOCATIONS OF ALL WALL MOUNTED SENSORS, LOUVERS, CEILING DIFFUSERS, REGISTERS

AND GRILLES, AND ACTIVE CHILLED BEAMS ARE DETAILED ON THE ARCHITECTURAL REFLECTED

CEILING PLANS AND INTERIOR ELEVATIONS.

2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST TO THE GOVERNMENT.

3. EXACT LOCATION OF ALL ROOF AND FLOOR OPENINGS TO BE COORDINATED WITH CONSTRUCTION

WORK AND ARCHITECTURAL AND STRUCTURAL DRAWINGS.

4. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS,

DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

5. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE

BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED.

6. PROVIDE FIRE DAMPERS AS SHOWN ON DRAWINGS AT ALL PENETRATIONS THROUGH FIRE RATED

WALLS AND FLOOR/CEILING. DAMPERS SHALL BE INSTALLED STRICTLY PER MANUFACTURERS

INSTRUCTIONS AND THE DAMPER'S LISTING.

7. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL

REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA)

8. DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS, INTERNAL DUCT LINER AND

EXTERNAL INSULATION ARE IN ADDITION TO THE DIMENSIONS SHOWN.

9. PENETRATION OF RATED ASSEMBLIES SHALL BE FIRE STOPPED USING AN APPROVED PENETRATION FIRESTOP AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE AN F AND T RATING OF NOT

LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLIES.

10. ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THE PLANS, IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR

THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) NATIONAL STANDARDS.

11. ALL OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL INCORPORATE DAMPERS THAT

AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE. THE DAMPERS SHALL BE EITHER

MOTORIZED OR OF THE GRAVITY TYPE.

12. PROVIDE INSULATED DOUBLE WALL DUCTWORK AT ALL EXPOSED AREAS AND FROM ALL AIR

HANDLING UNITS THROUGH THE FIRST 15 FEET LENGTH OF SUPPLY DUCTS.

13. SEE ARCHITECTURAL FOR LOUVERS AND SCHEDULES.

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

0'8' 16'8'

SCALE: 1/8" = 1'-0"

TRUENORTH

KEY PLAN

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS ANCHORAGE INTERNATIONAL AIRPORT

ANC-D-ATCT-

ATCT-TRACON

Stantec Architecture Inc.

725 East Fireweed Lane Suite 200

Anchorage, AK 99503-2245

Tel: (907) 276-4245 www.stantec.com

Project Number: 2014261000

Authorization to Practice # AECC1207

SUBMITTED BY APPROVED BY

DATE JCN

REVDRAWING NO

DESIGNED

DRAWN

CHECKED

REVIEWED BY

ISSUED BY

ANC ATCT-TRACON

ANCHORAGE

ALASKA

subttl appttl

H

G

E

C

A

D

F

B

1605098

06/11/2024

/1

/2

: 5 :0

P

M

M205

BASE BUILDING LEVEL 2 MECHANICAL PLAN - AREA

A

MSM

TR

SS

6/11/2024

S u b m itt a l P h a s e

MECHANICAL

1/8" = 1'-0"M205

A8 LEVEL 2 MECHANICAL - AREA A

KEYNOTES

V:01 INSTALL 6 IN DUCT DOWN THROUGH RATED FLOOR. PROVIDE WITH FD AND

VOLUME DAMPER. BALANCE TO 120 CFM.

V:03 VOLUME DAMPER ON BRANCH.

REV APPROVED DATE DESCRIPTION JCN REDLINE DATE APVD

T

MS

MS

MS

T

MS

T

MS

MS

MS

T

T

T

MS

MS

MS

MS

MSMS

MS

MS

MS

MS

MS

T

T

T

TA

TC

T3

T1

T2

TB

1 5

A

C

E

B

D

ELEV LOBBY

STAIR 2

ST2-2

STAIR 1

ST1-2

HALL-SOUTH

248S

LARGE CONF

QUIET RM

ADMIN STOR

MAIL-FILE-COPIER

PLUMB CHASE

ELECT CHASE

WOMEN'S RESTROOM

MEN'S RESTROOM

JANITOR

LOCKERS

CBI TRAIN

UNISEX TOILET/SHOWER

U N

IS

E

X T

LT

/S

H W

R /T

E S

T

TRACON

VESTIBULE

ACCESS AISLE

ACCESS AISLE

ATCT OPS SUP

NAS ELECTRONIC WORKSHOP

NAS TECH LIBRARY

231A

KITCHEN

BREAKROOM

TURNAGAIN SSC ATSS

LACTATION

STAIR 5

ST5-2

ATCT OPS SUP

ATCT OPS SUP

ATCT ATM

ATCT ADMIN SUPP

204A

DISTRICT ADMIN

204B

STARS SUPP SPEC

16"ø FLUE UP/DN

8"ø SA B-VAV3-9

B-VAV1-6

B-VAV1-7

B-VAV1-8

22"x20" SA

"ø

S A

10"ø SA

8"ø SA

32"x16" RA

B-VAV-3-22

B-VAV-3-19

12"ø RA

8" ø

S A

8"ø SA

8" ø

S A

6"ø

CB-4E

8"ø

CB-4C

8" ø

S A

6"ø SA

6"ø

CB-2B

8"ø

CB-4F

4"ø SA

6"ø

CB-2K

LINK 2

6" ø

S A

"ø

S A

6"ø

CB-3D

6"ø SA 18"ø SA DN

4"ø SA

12"ø SA

18"x10" TA 18"x10" TA

B-VAV3-8

20"x22" SA UP

TO AHU-1A/1B

6"ø

CB-2C

6"ø

CB-3E

10"ø SA

12"ø SA

10"ø SA8"ø SA

6"ø SA

12"x12" SA

18"ø SA

B-VAV-3-24

B-VAV-3-20

12"ø EA

6"ø RA

"ø

R A

"ø

R A

12"ø RA

6"ø RA

8" ø

R A6"ø SA

4"ø SA

B-VAV1-4

B-VAV1-3

10"x10" SA DN

6" ø

S A

"x

S A

12"x12" RA DN

"ø

R A

10"x10" SA

16"x14" RA

36"x20" RA UP

TO AHU-1A/1B

8"ø R-1

22"x14"

T-2

22"x14"

T-2

6"ø R-1

8"ø R-1

8" ø

R A

8" ø

S A

8" ø

R A —

8"ø R-1

10"ø RA

6"ø R-1

10"ø RA

6"ø RA 4"ø S-5

6"ø

CB-3A

8"ø

CB-3A

B-VAV1-9

6"ø

CB-4D

10"ø SA

10"ø SA

6"ø SA

6"ø SA

6" ø

S A

14"ø RA

14"ø R-1

10"ø S-11

TO B-RH-1

10"ø S-11

10"ø S-11

10"ø R-1

10"x10" SA 10"x10" SA

6" ø

S A

6"ø R-1

"x

S A

10"ø S-11

6"ø E-1

8"ø E-1

8"ø E-1

8"ø E-1

6"ø SA

6"ø

CB-3C

46"x14" R-1

4"ø S-4

4" ø

S A

8"ø SA

"ø

S A

12"x48" S-8

12"x48" S-8

8"ø R-1

6"ø RA

12"ø SA

8" ø

S A

8"ø RA

6"ø SA

12"ø EA UP

20"ø SA

B-VAV1-5

"x

S A

8"x8" SA 8"x8" SA

10"ø SA

"ø

S A

12"ø SA

10"ø SA

10"ø SA

"ø

S A

12"ø SA

"ø

S A

8" ø

S A

10"ø SA

10"ø SA

10"ø SA

10"ø SA

B-VAV-3-10

TELCO-FTI

H A

LL

-S

O U

T H

W E

S T

8S

W

H A

LL

-E

A S

T

8E

B-VAV-3-18

"ø

S A

"ø

R A

6"ø SA

6"ø SA

"ø

S A

12"x12" S-3

B-VAV-3-21

14"ø RA DN

26"x12" RA 12"ø RA

6"ø R-1

10"ø R-1

6"ø R-1

"x

S A

B-FCU-5-A-1

B-FCU-5-A-2

18"ø RA

"ø

R A

42"x10" RA42"x10" RA

10"ø SA

"x

R A

"x

R A

10"ø RA

12"x10"

R-3

22"x14"

T-2

22"x14"

T-2

22"x14"

T-2

22"x14"

T-1

22"x14"

T-1

22"x14"

T-1

8"ø R-1

10"ø SA

12"ø R-1

16"ø R-1

8"x8" S-4

22"x22"

R-2

"ø

S A

14"ø EA UP/DN

M403

D6_______

M403

D4_______

M403

D5_______

M803

C2_______

B-KH-1

6"ø

CB-4B

6"ø

CB-4B

6"ø

CB-4B

6"ø

CB-8A

8"ø

CB-7A

6"ø

CB-3A

25 8"ø

CB-7A

6"ø

CB-3A

8"ø

CB-2H

6"ø

CB-8A

"x

S A

B-SA-SA1

"x

S A

"x

R A

14"x16" SA

B-SA-RA2A

12"x12"

R-1

6" ø

S A

10"x10" SA

22"x14"

T-1

22"x14"

T-1

6"ø SA

B-VAV3-27

B-VAV3-28

'-2

/4

10"ø RA

8" ø

E A

22"x14"

T-1

V:03

V:03

V:02

B-FCU-4-B

B-FCU-4-C

14"ø SA

10"ø SA

10"ø SA

8"ø SA

10"ø SA

26"x13" SA

16"ø RA

10"ø SA

10"ø SA

10"ø SA16 "ø

S A

16"ø SA

"ø

S A

"ø

S A

"ø

S A

B-FCU-4-A

10"ø SA

V:07

V:07

V:07V:07

SHEET NOTES - MECHANICAL

1. EXACT LOCATIONS OF ALL WALL MOUNTED SENSORS, LOUVERS, CEILING DIFFUSERS, REGISTERS

AND GRILLES, AND ACTIVE CHILLED BEAMS ARE DETAILED ON THE ARCHITECTURAL REFLECTED

CEILING PLANS AND INTERIOR ELEVATIONS.

2. DESIGN DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, BENDS ELBOWS OR

OTHER ELEMENTS WHICH MAY BE REQUIRED. CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AS NECESSARY FOR A COMPLETE INSTALLATION, WITH NO ADDITIONAL COST TO THE GOVERNMENT.

3. EXACT LOCATION OF ALL ROOF AND FLOOR OPENINGS TO BE COORDINATED WITH CONSTRUCTION

WORK AND ARCHITECTURAL AND STRUCTURAL DRAWINGS.

4. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS. CONTRACTOR TO PROVIDE ALL FITTINGS, TRANSITIONS,

DAMPERS, VALVES, AND OTHER DEVICES REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

5. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND MATERIALS INSTALLED OUTSIDE OF THE

BUILDING OR OTHERWISE EXPOSED TO THE WEATHER SHALL BE COMPLETELY WEATHERPROOFED.

6. PROVIDE FIRE DAMPERS AS SHOWN ON DRAWINGS AT ALL PENETRATIONS THROUGH FIRE RATED

WALLS AND FLOOR/CEILING. DAMPERS SHALL BE INSTALLED STRICTLY PER MANUFACTURERS

INSTRUCTIONS AND THE DAMPER'S LISTING.

7. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN ACCORDANCE WITH THE LOCAL

REGULATIONS AND PROCEDURES DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE

SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION. (SMACNA)

8. DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE CLEAR DIMENSIONS, INTERNAL DUCT LINER AND

EXTERNAL INSULATION ARE IN ADDITION TO THE DIMENSIONS SHOWN.

9. PENETRATION OF RATED ASSEMBLIES SHALL BE FIRE STOPPED USING AN APPROVED PENETRATION FIRESTOP AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER AND SHALL HAVE AN F AND T RATING OF NOT

LESS THAN THE REQUIRED FIRE RESISTANCE RATING OF THE ASSEMBLIES.

10. ALL SPACE CONDITIONING AND VENTILATION SYSTEMS SHALL BE BALANCED TO THE QUANTITIES SPECIFIED IN THE PLANS, IN ACCORDANCE WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC) OR

THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) NATIONAL STANDARDS.

11. ALL OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL INCORPORATE DAMPERS THAT

AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE. THE DAMPERS SHALL BE EITHER

MOTORIZED OR OF THE GRAVITY TYPE.

12. PROVIDE INSULATED DOUBLE WALL DUCTWORK AT ALL EXPOSED AREAS AND FROM ALL AIR

HANDLING UNITS THROUGH THE FIRST 15 FEET LENGTH OF SUPPLY DUCTS.

13. SEE ARCHITECTURAL FOR LOUVERS AND SCHEDULES.

TH

ME-11897

R E

G

IS

TERED

PROFESS I ONAL

ENG

I N

E E

R

ST

ATE OF ALASKA

MICHAEL S. MACEDO

0'8' 16'8'

SCALE: 1/8" = 1'-0"

TRUENORTH

KEY PLANKEY PLAN

8 7 6 5 4 3 2 1

H

G

E

C

A

D

IS

S

U E

D F

O R

B

IM

C

L O

U D

C O

L L A

B O

R A

T

IO

N S

T A

N T

E C

C O

N S

U L T

IN

G

R

E V

IT

F

B

8 7 6 5 4 3 2 1

ATO - TECHNICAL OPERATIONS

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

WESTERN SERVICE AREA

ANCHORAGE ALASKATED STEVENS…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .