This solicitation is for new family housing construction at Villaggio Southwest and Camp Ederle North in Vicenza, Italy. The solicitation seeks proposals for design and construction services including site preparation, utilities, streets and roads, and 142 housing units comprised of townhomes, apartments, and officer housing. Proposals are due by September 15, 2020 and the contract is to be awarded by January 15, 2021. The period of performance is 730 calendar days from notice to proceed. The total contract value is estimated between $75-150 million. The set-aside is for small business and the contracting agency is the Naval Facilities Engineering Command. The incumbent contractor was not identified.
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE SUPPRESSION LEGENDS AND SYMBOLS /
SPEGNIMENTO INCENDIO - NOTE GENERALI E SIMBOLI
SYMBOL /
SIMBOLO
DESCRIPTION /
DESCRIZIONE
FIRE DEPARTMENT INLET CONNECTION (FDC) /
CONNESSIONE INGRESSO VIGILI DEL FUOCO (FDC)
GATE VALVE - OS&Y /
VALVOLA A SARACINESCA CON STELO ESTERNO E GIOGO
RISER /
COLONNA MONTANTE
FIRE SUPPRESSION GENERAL NOTES /
NOTE GENERALI ESTINZIONE INCENDI
1. FIRE SUPPRESSION SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13D (LATEST EDITION)
FOR ALL TOWNHOUSES AND SINGLE FAMILY HOUSES. /
IL SISTEMA DI SPEGNIMENTO INCENDIO DEVE ESSERE FORNITO IN CONFORMITA' A NFPA 13D (ULTIMA
EDIZIONE) PER TUTTE LE TOWNHOUSE (TH) E CASE UNIFAMILIARI (SF).
2. FIRE SUPPRESSION SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 13
(LATEST EDITION) FOR ALL APARTMENTS. /
IL SISTEMA DI SPEGNIMENTO DEVE ESSERE FORNITO IN CONFORMITA' ALLA UFC-3-600-01 E NFPA 13
(ULTIMA EDIZIONE) PER TUTTI GLI APPARTAMENTI.
3. OFH AND TOWNHOUSE RISERS SHALL BE LOCATED IN MECHANICAL SPACES WITH EXTERIOR ACCESS. /
LE COLONNE MONTANTI DELLE OHF E TWONHOUSE DEVONO ESSERE POSIZIONATE IN SPAZI
MECCANICI CON ACCESSO DALL'ESTERNO.
4. ALL PIPING EXPOSED TO THE EXTERIOR SHALL BE WRAPPED WITH HEAT TAPE FOR FREEZE
PROTECTION. /
TUTTE LE TUBAZIONI ESTERNE ESPOSTE DEVONO ESSERE AVVOLTE CON NASTRI PER LA PROTEZIONE
DAL GELO.
5. FIRE SUPPRESSION DRAWINGS AND RISER DIAGRAMS ARE SCHEMATIC. FINAL ROUTING OF PIPES AND
CONDUITS SHALL BE COORDINATED BY THE CONTRACTOR. /
I DISEGNI E GLI SCHEMI DELLE MONTANTI DELL'IMPINAOT DI SPEGNIMENTO INCENDI SONO SCHEMATICI.
IL PERCORSO FINALE DELLE TUBAZIONI E DELLE CONDOTTE DEVE ESSERE COORDINATO
DALL'APPALTATORE.
6. SEE CIVIL DRAWINGS FOR SITE WIDE FIRE WATER LOOP, FIRE HYDRANT LOCATIONS, AND GENERAL
SITE PLANS. /
FARE RIFERIMENTO AI DISEGNI CIVILI PER L'ANELLO PIU' AMPIO DELL'ACQUA ANTINCENDIO DEL SITO, LE POSIZIONI DEGLI IDRANTI ANTINCENDIO E LE PLANIMETRIE GENERALI DEL SITO.
7. SEE LIFE SAFETY DRAWINGS FOR CODE ANALYSIS AND PENETRATION PROTECTION REQUIREMENTS. / FARE RIFERIMENTO AI DISEGNI DELLA SICUREZZA PER L'ANALISI DELLA NORMATIVA ED I REQUISITI
DELLE SIGILLATURE DEGLI ATTRAVERSAMENTI.
8. TYPICAL DRAWINGS HAVE BEEN PROVIDED WHERE APPLICABLE FOR SIMPLICITY. SOME DRAWING NUMBERS ARE NOT USED IN ORDER TO RETAIN SIMILAR DRAWING ORGANIZATION TO ARCHITECTURAL DRAWING SET. / PER SEMPLICITA' SONO STATI PREDISPOSTI DOVE APPLICABILI DISEGNI TIPICI. ALCUNE NUMERAZIONI DEI DISEGNI NON SONO UTILIZZATE IN ORDINE PROGRESSIVO PER OTTENERE UNA
ORGANIZZAZIONE DEI DISEGNI SIMILARE A QUELLA DEL SET DI DISEGNI ARCHITETTONICI.
9. SEISMIC BRACING FOR EQUIPMENT AND PIPING WILL BE PROVIDED BASED ON THE SEISMIC DESIGN CATAGORY. / SUPPORTI ANTISISMICI PER APPARATIE E TUBAZIONI SARANNO FORNITI IN OPERA IN BASE
ALLA CATEGORIA SISMICA DI PROGETTO.
10. PROVIDE CONCEALED SPRINKLER HEADS IN ALL LIVING SPACES. / INSTALLARE TESTINE SPRINKLER
INCASSATE IN TUTTI GLI SPAZI DI SOGGIORNO
GATE VALVE /
VALVOLA A SARACINESCA
CHECK VALVE /
VALVOLA DI RITEGNO
FS FLOW SWITCH /
FLUSSOSTATO
STANDPIPE /
IDRANTE, TUBAZIONE MONTANTE VERTICALE
SIDEWALL DRY SPRINKLER HEAD FOR PROTECTION BELOW BALCONY ABOVE /
TESTINA SPRINKLER A SECCO DA PARTE LATERALE PER PROTEZIONE SOTTOSTANTE
IL BALCONE SUPERIORE
BACKFLOW PREVENTER /
VALVOLA DI NON RITORNO
PRESSURE SWITCH /
PRESSOSTATO
FIRE EXTINGUISHER /
ESTINTORE
PS
FE
ZONE CONTROL /
CONTROLLO DI ZONA
ZC
SINGLE FAMILY OR TOWNHOUSE SHALL BE SPRINKLERED IN
ACCORDANCE WITH NFPA 13D (2 mm/MINUTE) OR SPRINKLER
LISTING, WHICHEVER IS GREATER.
APARTMENT BUILDINGS SHALL BE SPRINKLERED IN
ACCORDANCE WITH UFC 3-600-01 AND NFPA 13:
1. DWELLING UNITS, STAIRWELLS, AND CORRIDORS SHALL BE
4mm/MINUTE OVER A 140m2 AREA.
MECHANICAL ROOMS SHALL BE 8mm/MINUTE OVER A 230m2
AREA. 13 - /
CASE UNIFAMILIARI O TOWNHOUSE DEVONO ESSERE DOTATE
DI SPRINKLER IN CONFORMITA' ALLA NFPA 13D (2mm/MINUTO) O
DEGLI SPRINKLER ELENCATI, A SECONDA DEL VALRE
MAGGIORE.
GLI EDIFICI PER APPARTAMENTI DEVONO ESSERE DOTATI DI
SPRINKLER IN CONFORMITA' A UFC-3-600-01 E NFPA13:
1. UNITA' ABITATIVE, VANI SCALE E CORRIDOI DEVONO ESSERE
4mm/MINUTO SU UN'AREA DI 140m2.
I LOCALI PER IMPIANTI MECCANICI DEVONO ESSERE
8mm/MINUTO SU UN'AREA DI 230m2. 13 -
APARTMENT BUILDINGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
EDIFICI AD APPARTAMENTI:
ZONA CON SPRINCKLER ASCIUTTI IN CONFORMITA' A NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13D:
1. IN CLOSETS LESS THAN 2.2m2
2. BATHROOMS LESS THAN 5.1m2
3. OPEN ATTACHED PORCH /
GLI SPRINKLER NON SONO RICHIESTI DA NFPA 13D:
1 - IN GUARDAROBA PIU' PICCOLI DI 2.2 m2
2 - STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3 - PORTICI ADIACENTI ANNESSI
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
NO
HATCH
/ NESSUN
TRATTEGGIO
THE WATER SUPPLY AT CAMP EDERLE HAS BEEN TESTED AND FOUND
SUFFICIENT TO SUPPORT BOTH THE SPRINKLER SYSTEM AND
MANUAL WET STANDPIPES./
LA FORNITURA DI ACQUA A CAMP EDERLE E' STATA TESTATA ED E'
RISULTATA SUFFICIENTE PER SUPPORTARE SIA IL SISTEMA DI
SPRINKLER SIA GLI IDRANTI MANUALI AD ACQUA.
THE BASE WATER (DOMESTIC) SUPPLY AT VILLAGGIO HAS PROVEN TO
BE INSUFFICIENT FOR FIRE WATER USE; A NEW FIRE WATER SUPPLY
WILL BE INSTALLED. THE FIRE WATER SUPPLY WILL BE EXTENDED
FROM THE EXISTING PUMP HOUSE BUILDING 710 TO ALL OF THE
FAMILY HOUSING UNITS. THE FIRE WATER AND DOMESTIC WATER
SUPPLY WILL BE SEPARATE FOR ALL OF THE FAMILY HOUSING UNITS
IN ORDER TO PROVIDE SUFFICIENT FIRE WATER DEMAND AND TO
MAINTAIN FRESH DOMESTIC WATER. BACKFLOW PREVENTERS WILL
NOT BE PROVIDED ON THE FIRE WATER SYSTEM IN THE FAMILY
HOUSING AREAS. /
LA FORNITURA DELL'ACQUA (DOMESTICA) AL VILLAGGIO E' STATA
TESTATA ED E' RISULTATA ESSERE INSUFFICIENTE PER L'UTILIZZO DI
ACQUA AI FINI ANTINCENDIO: UNA NUOVA FORNITURA DI ACQUA
ANTINCENDIO DEVE ESSERE INSTALLATA. LA FORNITURA DELL'ACQUA
ANTINCENDIO DEVE ESSERE ESTESA DALL'ESITENTE EDIFICIO POMPE
710 A TUTTE LE CASE CASE UNIFAMILIARI. LE FORNITURE DI ACQUA
ANTINCENDIO E ACQUA PER CONSUMI DOMESTICI DOVRANNO
ESSERE SEPARATE PER TUTTE LE CASE UNIFAMILIARI IN MODO DA
FORNIRE SUFFICIENTE ACQUA ANTINCENDIO E PER MANTENERE
FRESCA L'ACQUA PER GLI USI DOMESTICI.
VALVOLE DI NON RITORNO NON SARANNO INSTALLATE NEL SISTEMA
DI ACQUA ANTINCENDIO NELL'AREA DELLE CASE UNIFAMILIARI.
WATER SUPPLY /
FORNITURA ACQUA
ABBREVIATIONS /
ABBREVIAZIONI
AFF
APT
BLDG
BR
OFH
T.H
FX
ABOVE FINISHED FLOOR /
AL DI SOPRA DEL PAVIMENTO FINITO
APARTMENT /
APPARTAMENTO
BUILDING /
EDIFICIO
BEDROOM /
CAMERA DA LETTO
OFFICER HOUSING /
CASA DEGLI UFFICIALI
TOWNHOUSE /
TOWNHOUSE
FIRE SUPPRESSION /
ESTINZIONE INCENDI
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -G
EN
ER
AL
N
O
TE
S
AN
D
SY
M
BO
LS
ES
TI
NZ
IO
NE
IN
CE
ND
I-
NO
TE
G
EN
ER
AL
I E
S
IM
BO
LI
FX001
CL AK SL
14083463
DESCRIPTION / DESCRIZIONE VALUE / VALORE
STATIC PRESSURE /
PRESSIONE STATICA
RESIDUAL PRESSURE /
PRESSIONE RESIDUA
TEST FLOW /
FLUSSO VERIFICATO
269 KPa
269 KPa
1,279 LPM
VILLAGIO WATER SUPPLY DATA / DATI FORNITURA IDRICA VILLAGGIO
DATE / DATA OCT - 18 - 2018
CONDUCTED BY /
ESEGUITO DA
ATLANTIC FIRE PROTECTION ENGINEERING
565 KPa
455 KPa
4,221 LPM
EDERLE WATER SUPPLY DATA /
SEP - 14 - 2019
JOSEPH GRAUPMANN / GIANCARLO
BASTIANELLO & CAPTAIN GOOD
NOTE: VILLAGIO WATER SUPPLY IS INSUFFICIENT FOR FIRE WATER USE. PRESSURE LIMITING DEVICE WILL BE RECALLIBERATED TO ACCOMODATE THE SYSTEM PRESSURE REQUIREMENT. / NOTA: LA FORNITURA D'ACQUA AL VILLAGGIO E' INSUFFICIENTE AI FINI ANTINCENDIO. DISPOSITIVI DI LIMITAZIONE DELLA
PRESSIONE SARANNO RICALIBRATI PER RISPETTARE I REQUISITI DI PRESSIONE NECESSARI.
DESCRIPTION / DESCRIZIONE
STATIC PRESSURE /
PRESSIONE STATICA
RESIDUAL PRESSURE /
PRESSIONE RESIDUA
TEST FLOW /
FLUSSO VERIFICATO
DATE / DATA
CONDUCTED BY /
ESEGUITO DA
VALUE / VALORE
DN 20
DN 50 CHECK VALVE /
DN 50 VALVOLA DI CONTROLLO
DN 50 GATE VALVE /
VALVOLA A SARACINESCA DN 50
WATER MOTOR
GONG /
GONG AD ACQUA
DN 50 TO WET PIPE SPRINKLER DISTRIBUTION SYSTEM /
DN 50 AL SISTEMA DI DISTRIBUZIONE DEI TUBI BAGNATI
DEGLI SPRINKLER
PRESSURE GAUGE /
MISURATORE DI
PRESSIONE
DRAIN VALVE /
VALVOLA DI
DRENAGGIO
WALL MOUNTED POST
INDICATOR VALVE WITH
LOCKING METHOD /
VALVOLA A
SARACINESCA MONTATA
A PARETE CON
DISPOSITIVO DI
BLOCCAGGIO OPEN
TO SPRINKLERS /
AGLI SPRINKLER
ZONE DRAIN VALVE (WITH PRESSURE RELIEF
WHERE REQUIRED) /
VALVOLA DI SCARICO DI ZONA (CON RILIEVO
DELLA PRESSIONE DOVE RICHIESTO)
WATERFLOW SWITCH /
SWITCH DEL FLUSSO D'ACQUA
PRESSURE GAUGE /
MISURATORE DI PRESSIONE
INDICATING CONTROL VALVE WITH VALVE
SUPERVISORY SWITCH /
VALVOLA DI INDICAZIONE APERTO/CHIUSO CON
SWITCH DELLA VALVOLA DI SUPERVISIONE
CHECK VALVE /
VALVOLA DI NON RITORNO
SIGHT GLASS /
VETRINO DI CONTROLLO
TEST VALVE /
VALVOLA DI PROVA
UNION WITH CORROSION RESISTANT ORIFICE (12mm) /
UNIONE CON OREFIZIO RESISTENTE ALLA
CORROSIONE
FIRE SERVICE MAIN /
SERVIZIO ANTINCENDIO PRINCIPALE
TO DRAIN /
ALLO SCARICO
2" 45 DEGREE ELBOW BUSHING WITH 1/2"
SMOOTH BORE CORROSION RESISTANT
OUTLET / BOCCOLA DEL GOMITO DA 2" 45
GRADI CON USCITA RESISTENTE ALLA
CORROSIONE A FORO LISCIO DA 1/2"
STAIRWELL FLOOR /
PAVIMENTO VANO SCALA
OUTSIDE GROUND LEVEL/
LIVELLO TERRENO ESTERNO
ZONE CONTROL DRAIN RISER / MONTANTE
DRENAGGIO CONTROLLO DI ZONA
SD
TEST & DRAIN /
TEST & DRENAGGIO
FS
COUNTER WEIGHT /
CONTRAPPESO
SD
SD
SDELEVATOR CAB /
CABINA ASCENSORE
ELEVATOR LOBBY /
SBARCO ASCENSORE
ELEVATOR LOBBY /
SBARCO ASCENSORE
ELEVATOR LOBBY /
SBARCO ASCENSORE
MACHINE ROOM /
LOCALE MACCHINA
ZONE CONTROL
VALVE ASSEMBLY /
MONTAGGIO
VALVOLA DI
CONTROLLO DI
ZONA
SD
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -G
EN
ER
AL
N
O
TE
S
AN
D
SY
M
BO
LS
EN
ST
IN
ZI
O
NE
IN
CE
ND
I-
NO
TE
G
EN
ER
AL
I E S
IM
BO
LI
FX002
CL AK SL
14083464
SCALE: N.T.S.1
OFH/TH MECHANICAL ROOM DETAIL / OFH/TH
DETTAGLI LOCALE IMPIANTI MECCANICI
SCALE: N.T.S.2
TYPICAL ZONE CONTROL FOR APARTMENTS
/ VALVOLA DI CONTROLLO ZONA TIPO PER
APPARTAMENTI
SCALE: 1 : 50 (FX100)3
ZONE CONTROL DRAIN PIPE DETAIL /
DETTAGLIO TUBAZIONE DRENAGGIO
CONTROLLO DI ZONA
SCALE: NTS4
ELEVATOR & MACHINE ROOM SPRINKLER
DETAILS / DETTAGLI SPRINKLER
ASCENSORE E LOCALE MACCHINA
ELE
C
SUBSTA
BUILDING 1BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
FIRE DEPARTMENT CONNECTION /
CONNESSIONE VIGILI DEL FUOCO
FIRE DEPARTMENT CONNECTION /
CONNESSIONE VIGILI DEL FUOCO
FIRE DEPARTMENT CONNECTION /
CONNESSIONE VIGILI DEL FUOCO
FIRE HYDRANT /
IDRANTE ANTINCENDIO
FIRE HYDRANT /
IDRANTE ANTINCENDIO
FIRE HYDRANT /
IDRANTE ANTINCENDIO
FIRE HYDRANT /
IDRANTE ANTINCENDIO
EDERLE APARTMENT QUANTITIES /
QUANTITA' APPARTAMENTI EDERLE
BUILDING /
COSTRUZIONE
APT BLDG 1
APT BLDG 2
APT BLDG 3
APT BLDG 4
APT BLDG 5
APT BLDG 6
UNIT TYPE
/ TIPO DI
UNITÀ
QUANTITY /
QUANTITÀ
3BR
3BR
3BR
3BR
3BR
3BR
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:300
6M 12M 24M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D C O M P G .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
SI
TE
P
LA
N
/ S
PE
G
NI
M
EN
TO
IN
CE
ND
IO
PL
AN
IM
ET
RI
A
ED
ER
LE
FXS001
CL AK SL
14083465
8681 : 300FXS001
FX - EDERLE SITE PLAN /
FX - PLANIMETRIA EDERLE
ELEC
SUBSTA
TWO-WAY TRAFFIC
ONE-WAY TRAFFIC
ONE-WAY TRAFFIC
OFH
UNIT 1
OFH
UNIT 2
OFH
UNIT 3
OFH
UNIT 4
OFH
UNIT 5
VILLAGGIO SUBSTATION BLDG 4 - TYPE 1/
SOTTOSTAZIONE VILLAGGIO BLDG 4 - TIPO 1
FIRE HYDRANT FH-O1 /
IDRANTE ANTINCENDIOFH-O1
DISTANCE TO FARTHEST PART
OF THE HOME: 77 m /
DISTANZA DALLA PIU' LONTANA
PARTE DI ABITAZIONE: 77m
FIRE WATER SUPPLY /
FORNITURA ACQUA ANTINCENDIO
FIRE WATER SUPPLY /
FORNITURA ACQUA
ANTINCENDIO
FIRE WATER SUPPLY /
FORNITURA ACQUA ANTINCENDIO
VILLAGGIO OFFICER HOUSING /
ALLOGGIO UFFICIALI VILLAGGIO
UNIT TYPE /
TIPO DI UNITÀ
QUANTITY /
QUANTITÀ
OFH 5
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:300
6M 12M 24M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D V
IL
C O M P G .r vt
FI
RE
S
UP
PR
ES
SI
O
N -V
IL
LA
G G
IO
S
IT
E
PL
AN
SP
EG
NI
M
EN
TO
IN
CE
ND
IO
PI
AN
TA
D
EL
S
IT
O
V
IL
LA
G
G
IO
FXS002
CL AK SL
14083466
1 : 300FXS002
OFH HOUSE SITE PLAN FX /
FX PIANTA DEL SITO OFH
ELEC
SUBSTA
TEMP ELEC
SUBSTA
FIR
E
LA
NE
FIR
E
LA
NE
TWO-WAY TRAFFIC
TWO-WAY TRAFFIC
ONE WAY
TW
O-
W
AY
TR
AF
FIC
ONE WAY
ONE WAY
ONE WAY
ONE WAY
ONE WAY
TOWNHOUSE BLK 1A
TOWNHOUSE BLK 2A
TOWNHOUSE BLK 3
VILLAGGIO
APT BLDG 1
TOWNHOUSE
BLK 4
VILLAGGIO
APT BLDG 2
TOWNHOUSE
BLOCK 5
TOWNHOUSE BLK 1B
TOWNHOUSE BLK 2B
VILLAGGIO
SUBSTATION BLDG 2
TYPE 1 /
SOTTOSTAZIONE
VILLAGGIO BLDG 2
DI TIPO 1
VILLAGGIO SUBSTATION
BLDG 3 - TYPE 1 /
SOTTOSTAZIONE VILLAGGIO
BLDG 3 - TIPO 1
VILLAGGIO
SUBSTATION BLDG 1
TYPE 1 /
SOTTOSTAZIONE
VILLAGGIO
BLDG 1 TIPO 1
FIRE DEPARTMENT
CONNECTION /
CONNESSIONE VIGILI DEL
FUOCO
FIRE HYDRANT FH-7 /
IDRANTE ANTINCENDIO FH-7
FIRE HYDRANT FH-5 /
IDRANTE ANTINCENDIO FH-5
FIRE HYDRANT FH-4 /
IDRANTE ANTINCENDIO FH-4
FIRE HYDRANT FH-1 /
IDRANTE ANTINCENDIO FH-1
FIRE HYDRANT FH-3 /
IDRANTE ANTINCENDIO FH-3
FIRE HYDRANT FH-8 /
IDRANTE ANTINCENDIO FH-8
FIRE HYDRANT FH-9 /
IDRANTE ANTINCENDIO FH-9
FIRE HYDRANT FH-2 /
IDRANTE ANTINCENDIO FH-2
FIRE HYDRANT FH-6 /
IDRANTE ANTINCENDIO FH-6
VILLAGGIO APT BLDG 1&2
UNIT TYPE / TIPO DI
UNITÀ
QUANTITY / QUANTITÀ
3BR 12
4BR 4
5BR 2
VILLAGGIO TOWNHOUSES
UNIT TYPE / TIPO DI
UNITÀ
QUANTITY / QUANTITÀ
3BR
4BR
5BR
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:300
6M 12M 24M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D V
IL
C O M P G .r vt
FI
RE
S
UP
PR
ES
SI
O
N -V
IL
LA
G G
IO
S
IT
E
PL
AN
S
PE
G
NI
M
EN
TO
IN
CE
DI
O
PL
AN
IM
ET
RI
A
VI
LL
AG
G
IO
FXS003
CL AK SL
14083467
1 : 300FXS003
VILLAGGIO FX SITE PLAN /
VILLAGGIO FX PLANIMETRIA
• OFH OR TOWNHOUSE:
SPRINKLER IN ACCORDANCE WITH NFPA 13D /
OHF O TOWNHOUSE:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APARTMENT BUILDINGS:
SPRINKLER IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
EDIFICI PER APPARTAMENTI:
SPRINKLER IN CONFORMITA' A UFC 4-711-01 E NFPA 13
FIRE SUPPRESSION HATCHING /
TRATTEGGI ESTINZIONE INCENDI
GENERAL NOTES /
NOTE GENERALI
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. /
VEDI TAVOLE FAS001-FAS003 PER LE PLANIMETRIE DELL'ALARME
INCENDI DEL SITO.
2. EDERLE APT BLDG 2 IS A MIRROR IMAGE OF EDERLE APT BLDG 1.
THIS DRAWING APPLIES TO EDERLE APT BLDG 2 OPPOSITE HAND.
EDERLE APT BLDG 2 DRAWINGS NOT INCLUDED IN DRAWING SET. /
L'APT BLDG 2 DI EDERLE E' L'IMMAGINE SPECCHIATA DEL'APT BLDG
1 DI EDERLE. QUESTO DISEGNO SI APPLICA AD APT BLDG 2 DI
EDERLE ALL'INVERSO. I DISEGNI DELL'APT BLDG 2 DI EDERLE NON
SONO INCLUSI NEL SET DI DISEGNI.
• APARTMENT BUILDINGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
EDIFICI AD APPARTAMENTI:
ZONA CON SPRINCKLER ASCIUTTI IN ACCORDO CON
NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR NECESSARI SECONDO NFPA 13:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 m2
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3. PORTICATI APERTI IN ADIACENZA
NO HATCH
\NESSUNA
CAMPITURA
ZC
GAR
STREET STAIR
COURT STAIR
MECH
ELEC
1.6
FX420
1.11
FE FE
1.24
1.13
ELEV
MECHCOMM
CORR
CORR
FX420
1.8
1.31
1.40
1.36
1.41
1.361.311.8
MECH
1.43
FX002
M BDR
M CLS
M BTH
BTH 2
LAUN
CIRC
BDR 3
BDR 2
LIV
FAM
STOR
FOY
DIN
KIT
BALC
1.42
1.45
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
G
RO
UN
D
FL
O
O R
/ E
ST
IN
ZI
O
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
P
IA
NO
T
ER
RA
FX100
CL AK SL
14083468
SCALE: 1 : 100
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 1 - GROUND FLOOR /
PIANTA ESTINZIONE INCENDI - EDERLE APT
BLDG 1 - PIANO TERRA
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.6 150 mm FIRE WATER FROM BASE SUPPLY / TUBAZIONE DA 150 mm
PER ACQUA ANTINCENDIO DALL'ARRIVO FORNITURA
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.11 FIRE DEPARTMENT CONNECTION (FDC) / CONNESSIONE VIGILI DEL
FUOCO (VVF)
1.13 WET PIPE SPRINKLER DISTRIBUTION ON FLOOR / DISTRIBUZIONE
DELLE TUBAZIONI DELL' IMPIANTO SPRINKLER AD ACQUA AL PIANO
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.31 STANDPIPE UP / TUBAZIONE DI SCARICO IN SALITA
1.36 CONTROL VALVE/VALVOLA DI CONTROLLO
1.40 PIPE TO PROTECT GROUND LEVEL CORRIDOR AND COMM
ROOM/TUBAZIONE A PROTEZIONE DEL CORRIDOIO AL PIANO TERRA
E DELLA STANZA COMM
1.41 ORIENT FDC TO ALLOW FOR MAXIMUM HOSE CLEARANCE/ INDICARE
IL PERCORSO DEI VVF AL FINE DI CONSENTIRE IL MASSIMO
ALLUNGAMENTO DEL TUBO
1.42 EXPOSED PIPING IN GARAGE SHALL BE PROTECTED FROM
FREEZING WITH HEAT TRACE (SEE DETAILS ON ELECTRICAL
SHEETS)/ LE TUBAZIONI ESPOSTE IN GARAGE DEVONO ESSERE
PROTETTE DAL GELO CON CAVI SCALDANTI (VEDI DETTAGLI SULLE
TAVOLE ELETTRICHE)
1.43 FDC PIPING IS DRY AND HEAT TRACE IS NOT REQUIRED/LA
TUBAZIONE DEI VVF E' A SECCO E NON E' RICHIESTO IL CAVO
SCALDANTE
1.45 PROVIDE WALL MOUNTED POST INDICATOR VALVE WITH
TAMPERING SWITCH / FORNITURA E POSA IN OPERA INDICATORE DI
POSIZIONE A PARETE CON VALVOLA E INTERRUTTORE
ANTIMANOMISSIONE
COURT STAIR
CORR
STREET STAIR
MECH
ELEV
1.27
ZC
1.91.10
FE FE
1.24
CORR
M BDR
FAM
LAUN
BALC
KIT
DIN
CIRC
BTH 2FOY
BDR 3 BDR 2
M CLS
LIV
STOR
M BDR
M CLS
BDR 2
BDR 3 LIV
FAM
FOY
LAUN
BTH 2
M BTH
BALC
KIT
DIN
CIRC
STOR
1.8
FX420
1.27
MECH
• OFH OR TOWNHOUSE:
SPRINKLER IN ACCORDANCE WITH NFPA 13D /
OHF O TOWNHOUSE:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APARTMENT BUILDINGS:
SPRINKLER IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
EDIFICI PER APPARTAMENTI:
SPRINKLER IN CONFORMITA' A UFC 4-711-01 E NFPA 13
FIRE SUPPRESSION HATCHING /
TRATTEGGI ESTINZIONE INCENDI
GENERAL NOTES /
NOTE GENERALI
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. /
VEDI TAVOLE FAS001-FAS003 PER LE PLANIMETRIE DELL'ALARME
INCENDI DEL SITO.
2. EDERLE APT BLDG 2 IS A MIRROR IMAGE OF EDERLE APT BLDG 1.
THIS DRAWING APPLIES TO EDERLE APT BLDG 2 OPPOSITE HAND.
EDERLE APT BLDG 2 DRAWINGS NOT INCLUDED IN DRAWING SET. /
L'APT BLDG 2 DI EDERLE E' L'IMMAGINE SPECCHIATA DEL'APT BLDG
1 DI EDERLE. QUESTO DISEGNO SI APPLICA AD APT BLDG 2 DI
EDERLE ALL'INVERSO. I DISEGNI DELL'APT BLDG 2 DI EDERLE NON
SONO INCLUSI NEL SET DI DISEGNI.
• APARTMENT BUILDINGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
EDIFICI AD APPARTAMENTI:
ZONA CON SPRINCKLER ASCIUTTI IN ACCORDO CON
NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR NECESSARI SECONDO NFPA 13:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 m2
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3. PORTICATI APERTI IN ADIACENZA
NO HATCH
\NESSUNA
CAMPITURA
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
T
YP
IC
AL
F
LO
O R
/ E
ST
IN
ZI
O
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
P
IA
NI
T
IP
O
FX101
CL AK SL
14083469
SCALE: 1 : 100
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 1 - FIRST FLOOR (TYPICAL OF SECOND
AND THIRD FLOORS) /
PIANTA ESTINZIONE INCENDI - EDERLE APT
BLDG 1 - PRIMO PIANO (TIPICO DEL
SECONDO E TERZO PIANO)
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.27 STANDPIPE UP AND DOWN/ TUBAZIONE DI SCARICO IN SALITA
SALITA E DISCESA
1.8
ZC
1.9
1.8
1.10
FE
1.24
M BDR
FAM
LAUNM BTH
BALC
KIT
DIN
CIRC
BTH 2 FOY
BDR 3BDR 2
M CLS
LIV
STOR
ELEV
MECH
CORR
MECH
STREET STAIR
COURT STAIR
FX420
1.28
1.27
ROOF
• OFH OR TOWNHOUSE:
SPRINKLER IN ACCORDANCE WITH NFPA 13D /
OHF O TOWNHOUSE:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APARTMENT BUILDINGS:
SPRINKLER IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
EDIFICI PER APPARTAMENTI:
SPRINKLER IN CONFORMITA' A UFC 4-711-01 E NFPA 13
FIRE SUPPRESSION HATCHING /
TRATTEGGI ESTINZIONE INCENDI
GENERAL NOTES /
NOTE GENERALI
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. /
VEDI TAVOLE FAS001-FAS003 PER LE PLANIMETRIE DELL'ALARME
INCENDI DEL SITO.
2. EDERLE APT BLDG 2 IS A MIRROR IMAGE OF EDERLE APT BLDG 1.
THIS DRAWING APPLIES TO EDERLE APT BLDG 2 OPPOSITE HAND.
EDERLE APT BLDG 2 DRAWINGS NOT INCLUDED IN DRAWING SET. /
L'APT BLDG 2 DI EDERLE E' L'IMMAGINE SPECCHIATA DEL'APT BLDG
1 DI EDERLE. QUESTO DISEGNO SI APPLICA AD APT BLDG 2 DI
EDERLE ALL'INVERSO. I DISEGNI DELL'APT BLDG 2 DI EDERLE NON
SONO INCLUSI NEL SET DI DISEGNI.
• APARTMENT BUILDINGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
EDIFICI AD APPARTAMENTI:
ZONA CON SPRINCKLER ASCIUTTI IN ACCORDO CON
NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR NECESSARI SECONDO NFPA 13:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 m2
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3. PORTICATI APERTI IN ADIACENZA
NO HATCH
\NESSUNA
CAMPITURA
COURT STAIR
ZC
FE
1.24ELEV
MECH
FX420
1.14
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
F O
UR
TH
F
LO
O R
RO
O F
ES
TI
NZ
IO
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
Q
UA
RT
O P
IA
NO
T
ET
TO
FX104
CL AK SL
14083470
SCALE: 1 : 1001
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 1 - FOURTH FLOOR /
PIANTA ESTINZIONE INCENDIO- EDERLE APT
BLDG 1 - QUARTO PIANO
SCALE: 1 : 100 (FX420)2
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 1 - ROOF LEVEL /
PIANTA ESTINZIONE INCENDI - EDERLE APT
BLDG 1 - LIVELLO TETTO
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.14 ZONE CONTROL FOR ELEVATOR MACHINE ROOM / ZONA DI
CONTROLLO DELLA SALA MACCHINE DEGLI ASCENSORI
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.27 STANDPIPE UP AND DOWN/ TUBAZIONE DI SCARICO IN SALITA
1.28 STANDPIPE DOWN / TUBAZIONE DI SCARICO IN DISCESA
• SF OR TH:
SPRINKLE IN ACCORDANCE WITH NFPA 13D /
SF O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APT BLDGS:
SPRINKLE IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
APT BLDGS:
SPRINKLER IN CONFORMITA' A UFC 4-711-01 E NFPA
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. / VEDI
TAVOLE FAS001-FAS003 PER PLANIMETRIE DELL'IMPIANTO ALLARME
INCENDI DEL SITO.
2. EDERLE APT BLDG 4 IS A MIRROR IMAGE OF EDERLE APT BLDG 3. THIS
DRAWING APPLIES TO EDERLE APT BLDG 4 OPPOSITE HAND. EDERLE APT
BLDG 4 DRAWINGS NOT INCLUDED IN DRAWING SET. / L'APT BLDG 4 DI
EDERLE E' L'IMMAGINE SPECCHIATA DELL'APT BLDG 3. QUESTO DSEGNO SI
APPLICA IN MANIERA SPECCHIATA ALL'APT BLDG 4 DI EDERLE. I DISEGNI DI
EDERLE APT BLDG 4 NON SONO INCLUSI NEL SET DI DISEGNI.
GENERAL NOTES /
NOTE GENERALI
• APT BLDGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
APT BLDGS:
ZONA CON SPRINCKLER A SECCO IN ACCORDO CON
NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR RICHIESTI PER NFPA 13:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 m2
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3. PORTICATI APERTI IN ADIACENZA
NO HATCH
\NESSUNA
CAMPITURA
Z C
1.8
1.8 1.10
1.9
FE
1.24
FE
1.5
1.18
ELEC
MECH
COMM
CORRCORR
STREET STAIR
GAR
FX421
FX421
1.25
1.26
1.31
1.31
1.36
1.36
ELEV
MECH
COURT STAIR
MECH
1.43
1.41
1.6
1.45 1.34
BALC
KIT
DIN
FOY
STOR
FAM
CIRCLAUN
BTH 2
M BTH
M CLS
M BDR
BDR 2
BDR 3
LIV
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
G
RO
UN
D
FL
O
O R
/ E
ST
IN
ZI
O
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
P
IA
NO
T
ER
RA
FX120
CL AK SL
14083471
SCALE: 1 : 100
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 3 - GROUND FLOOR /
PIANTA ENSTINZIONE INCENDI - EDERLE APT
BLDG 3 - PIANO TERRA
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.5 DRY SPRINKLER COVERAGE OF GARAGE / IMPIANTO SPRINKLER DI
SCARICO A SECCO A COPERTURA DEL GARAGE
1.6 150 mm FIRE WATER FROM BASE SUPPLY / TUBAZIONE DA 150 mm
PER ACQUA ANTINCENDIO DALL'ARRIVO FORNITURA
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.18 FDC / DIPARTIMENTO VIGILI DEL FUOCO (VVF)
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.25 PIPING SHOWN HERE IS ON GROUND FLOOR A / IL SISTEMA DI
TUBAZIONI INDICATO QUI E' AL PIANO TERRA A
1.26 PIPING SHOWN HERE IS ON GROUND FLOOR A AND IS FED DOWN
FROM FIRST FLOOR SYSTEM / IL SISTEMA DI TUBAZIONI INDICATO
QUI E' AL PIANO TERRA A ED E' ALIMENTATO DAL SISTEMA DEL
PRIMO PIANO
1.31 STANDPIPE UP / TUBAZIONE DI SCARICO IN SALITA
1.34 TO MAIN DRAIN/ALLO SCARICO PRINCIPALE
1.36 CONTROL VALVE/VALVOLA DI CONTROLLO
1.41 ORIENT FDC TO ALLOW FOR MAXIMUM HOSE CLEARANCE/ INDICARE
IL PERCORSO DEI VVF AL FINE DI CONSENTIRE IL MASSIMO
ALLUNGAMENTO DEL TUBO
1.43 FDC PIPING IS DRY AND HEAT TRACE IS NOT REQUIRED/LA
TUBAZIONE DEI VVF E' A SECCO E NON E' RICHIESTO IL CAVO
SCALDANTE
1.45 PROVIDE WALL MOUNTED POST INDICATOR VALVE WITH
TAMPERING SWITCH / FORNITURA E POSA IN OPERA INDICATORE DI
SF O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APT BLDGS:
SPRINKLE IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
APT BLDGS:
SPRINKLER IN CONFORMITA' A UFC 4-711-01 E NFPA
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. / VEDI
TAVOLE FAS001-FAS003 PER PLANIMETRIE DELL'IMPIANTO ALLARME
INCENDI DEL SITO.
2. EDERLE APT BLDG 4 IS A MIRROR IMAGE OF EDERLE APT BLDG 3. THIS
DRAWING APPLIES TO EDERLE APT BLDG 4 OPPOSITE HAND. EDERLE APT
BLDG 4 DRAWINGS NOT INCLUDED IN DRAWING SET. / L'APT BLDG 4 DI
EDERLE E' L'IMMAGINE SPECCHIATA DELL'APT BLDG 3. QUESTO DSEGNO SI
APPLICA IN MANIERA SPECCHIATA ALL'APT BLDG 4 DI EDERLE. I DISEGNI DI
EDERLE APT BLDG 4 NON SONO INCLUSI NEL SET DI DISEGNI.
GENERAL NOTES /
NOTE GENERALI
• APT BLDGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
APT BLDGS:
ZONA CON SPRINCKLER A SECCO IN ACCORDO CON
NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR RICHIESTI PER NFPA 13:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 m2
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3. PORTICATI APERTI IN ADIACENZA
NO HATCH
\NESSUNA
CAMPITURA
ZC
1.8
1.9
1.8
FE
F E
1.24ELEVCORR
CORR
MECH
STREET STAIR
COURT STAIR
M BDR
FAM
LAUN
BALC
KIT
DIN
CIRC
BTH 2
FOY
BDR 3
BDR 2
M CLS
LIV
STOR
M BDR
M CLS
BDR 2
BDR 3LIV
FAM
FOY
LAUN
BTH 2
M BTH
BALC
KIT
DIN
CIRC
STOR
FX421 1.27
1.27
1.10
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
T
YP
IC
AL
F
LO
O R
/ E
ST
IN
ZI
O
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
P
IA
NO
T
IP
IC
O
FX121
CL AK SL
14083472
SCALE: 1 : 100
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 3 - FIRST FLOOR (TYPICAL OF SECOND
AND THIRD FLOORS) /
PIANTA ESTINZIONE INCENDI - EDERLE APT
BLDG 3 - PRIMO PIANO (TIPICO SECONDO E
TERZO PIANO)
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
SF O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APT BLDGS:
SPRINKLE IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
APT BLDGS:
SPRINKLER IN CONFORMITA' A UFC 4-711-01 E NFPA
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. / VEDI
TAVOLE FAS001-FAS003 PER PLANIMETRIE DELL'IMPIANTO ALLARME
INCENDI DEL SITO.
2. EDERLE APT BLDG 4 IS A MIRROR IMAGE OF EDERLE APT BLDG 3. THIS
DRAWING APPLIES TO EDERLE APT BLDG 4 OPPOSITE HAND. EDERLE APT
BLDG 4 DRAWINGS NOT INCLUDED IN DRAWING SET. / L'APT BLDG 4 DI
EDERLE E' L'IMMAGINE SPECCHIATA DELL'APT BLDG 3. QUESTO DSEGNO SI
APPLICA IN MANIERA SPECCHIATA ALL'APT BLDG 4 DI EDERLE. I DISEGNI DI
EDERLE APT BLDG 4 NON SONO INCLUSI NEL SET DI DISEGNI.
GENERAL NOTES /
NOTE GENERALI
• APT BLDGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
APT BLDGS:
ZONA CON SPRINCKLER A SECCO IN ACCORDO CON
NFPA 13
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR RICHIESTI PER NFPA 13:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 m2
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 m2
3. PORTICATI APERTI IN ADIACENZA
NO HATCH
\NESSUNA
CAMPITURA
ZC
1.8 1.27
1.9
FE
1.24
ELEV
CORR
MECH
STREET STAIR
COURT STAIR
M BDR
FAM
LAUN M BTH
BALC
KIT
DIN
CIRC
BTH 2FOY
BDR 3 BDR 2
M CLS
LIV
STOR
FX421
1.10
ROOF
Z C F E
1.8
MACH
ELEV
FX421
1.28 1.10
1.24
ROOF
ROOF
1.14
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
F O
UR
TH
F
LO
O R
RO
O F
ES
TI
NZ
IO
NE
IN
CE
ND
I E
DE
RL
E
AP
T
BL
DG
Q
UA
RT
O
P
IA
NO
T
ET
TO
FX124
CL AK SL
14083473
SCALE: 1 : 1001
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 3 - FOURTH FLOOR /
PIANTA ESTINZIONE INCENDI - EDERLE APT
BLDG 3 - QUARTO PIANO
SCALE: 1 : 1002
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 3 - ROOF LEVEL /
PIANTA ESTINZIONE INCENDI - EDERLE APT
BLDG 3 - LIVELLO TETTO
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.14 ZONE CONTROL FOR ELEVATOR MACHINE ROOM / ZONA DI
CONTROLLO DELLA SALA MACCHINE DEGLI ASCENSORI
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.27 STANDPIPE UP AND DOWN/ TUBAZIONE DI SCARICO IN SALITA
SF O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APT BLDGS:
SPRINKLE IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
APT BLDGS:
SPRINKLER IN CONFORMITA' CON CON CON UFC
4-711-01 E NFPA 13
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE
PLANS. / VEDI TAVOLE FXS001-FXS003 PER LE PLANIMETRIE DI
ESTINZIONE INCENDI DEL SITO.
2. EDERLE APT BLDG 6 IS A MIRROR IMAGE OF EDERLE APT BLDG 5.
THIS DRAWING APPLIES TO EDERLE APT BLDG 6 OPPOSITE HAND.
EDERLE APT BLDG 6 DRAWINGS NOT INCLUDED IN DRAWING SET. /
L'APT BLDG 6 DI EDERLE E' L'IMMAGINE SPECCHIATA DELL'APT
BLDG 5 DI EDERLE. QUESTO DISEGNO SI APPLICA ALL'APT BLDG 6
DI EDELE IN MANIERA SPECCHIATA.I DIEGNI DELL'APT BLDG 6 DI
EDERLE NON SONO INCLUSI NEL SET DI DISEGNI.
GENERAL NOTES /
NOTE GENERALI
• APT BLDGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
APT BLDGS:
ZONA CON SPRINKLER A SECCO IN CONFORMITA' CON
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR RICHIESTI COME DA NFPA 13:
1. IN GUARDAROBA PIU' PICCOLI DI 2.2 MQ
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 MQ
3. PORTICATI E/O VERANDE
NO HATCH
\NESSUNA
CAMPITURA
ZC
1.11
1.6
FE
1.24
1.5
1.9
1.10
FX422
FX422
MECH
ELEC
GAR
COMM
CORR
COURT STAIR
STREET STAIR
M BDR
FAM
LAUN
BALC
KIT
DIN
CIRC
BTH 2 FOY
BDR 3BDR 2
M CLS
LIV
STOR
1.8
1.8
1.31
1.31
FE
MECH
ELEV
MECHCORR
1.41
1.45
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
G
RO
UN
D
FL
O
O R
/ E
ST
IN
ZI
O
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
-P
IA
NO
T
ER
RA
FX140
CL AK SL
14083474
SCALE: 1 : 100
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 5 - GROUND FLOOR /
PLANIMETRIA ESTINZIONE INCENDI - EDERLE
APT BLDG 5 - PIANO TERRA
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.5 DRY SPRINKLER COVERAGE OF GARAGE / IMPIANTO SPRINKLER DI
SCARICO A SECCO A COPERTURA DEL GARAGE
1.6 150 mm FIRE WATER FROM BASE SUPPLY / TUBAZIONE DA 150 mm
PER ACQUA ANTINCENDIO DALL'ARRIVO FORNITURA
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.11 FIRE DEPARTMENT CONNECTION (FDC) / CONNESSIONE VIGILI DEL
FUOCO (VVF)
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.31 STANDPIPE UP / TUBAZIONE DI SCARICO IN SALITA
1.41 ORIENT FDC TO ALLOW FOR MAXIMUM HOSE CLEARANCE/ INDICARE
IL PERCORSO DEI VVF AL FINE DI CONSENTIRE IL MASSIMO
ALLUNGAMENTO DEL TUBO
1.45 PROVIDE WALL MOUNTED POST INDICATOR VALVE WITH
TAMPERING SWITCH / FORNITURA E POSA IN OPERA INDICATORE DI
SF O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APT BLDGS:
SPRINKLE IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
APT BLDGS:
SPRINKLER IN CONFORMITA' CON CON CON UFC
4-711-01 E NFPA 13
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE
PLANS. / VEDI TAVOLE FXS001-FXS003 PER LE PLANIMETRIE DI
ESTINZIONE INCENDI DEL SITO.
2. EDERLE APT BLDG 6 IS A MIRROR IMAGE OF EDERLE APT BLDG 5.
THIS DRAWING APPLIES TO EDERLE APT BLDG 6 OPPOSITE HAND.
EDERLE APT BLDG 6 DRAWINGS NOT INCLUDED IN DRAWING SET. /
L'APT BLDG 6 DI EDERLE E' L'IMMAGINE SPECCHIATA DELL'APT
BLDG 5 DI EDERLE. QUESTO DISEGNO SI APPLICA ALL'APT BLDG 6
DI EDELE IN MANIERA SPECCHIATA.I DIEGNI DELL'APT BLDG 6 DI
EDERLE NON SONO INCLUSI NEL SET DI DISEGNI.
GENERAL NOTES /
NOTE GENERALI
• APT BLDGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
APT BLDGS:
ZONA CON SPRINKLER A SECCO IN CONFORMITA' CON
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR RICHIESTI COME DA NFPA 13:
1. IN GUARDAROBA PIU' PICCOLI DI 2.2 MQ
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 MQ
3. PORTICATI E/O VERANDE
NO HATCH
\NESSUNA
CAMPITURA
ZC
FE
1.24
1.9
FX422
CORRMECH
STREET STAIR
COURT STAIR
M BDR
FAM
LAUN
BALC
KIT
DIN
CIRC
BTH 2 FOY
BDR 3BDR 2
M CLS
LIV
STOR
M BDR
M CLS
BDR 2
BDR 3LIV
FAM
FOY
LAUN
BTH 2
M BTH
BALC
KIT
DIN
CIRC
STOR
1.8
1.27
1.8
1.27
1.10
FE
ELEV
MECHCORR
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
T
YP
IC
AL
F
LO
O R
/ E
ST
IN
ZI
O
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
-P
IA
NO
T
IP
O
FX141
CL AK SL
14083475
SCALE: 1 : 100
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 5 - FIRST FLOOR (TYPICAL OF SECOND
AND THIRD FLOORS) /
PLANIMETRIA ESTINZIONE INCENDI - EDERLE
APT BLDG 5 - PRIMO PIANO (TIPICO
SECONDO E TERZO PIANO)
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
SF O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APT BLDGS:
SPRINKLE IN ACCORDANCE WITH UFC 4-711-01 AND
NFPA 13 /
APT BLDGS:
SPRINKLER IN CONFORMITA' CON CON CON UFC
4-711-01 E NFPA 13
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE
PLANS. / VEDI TAVOLE FXS001-FXS003 PER LE PLANIMETRIE DI
ESTINZIONE INCENDI DEL SITO.
2. EDERLE APT BLDG 6 IS A MIRROR IMAGE OF EDERLE APT BLDG 5.
THIS DRAWING APPLIES TO EDERLE APT BLDG 6 OPPOSITE HAND.
EDERLE APT BLDG 6 DRAWINGS NOT INCLUDED IN DRAWING SET. /
L'APT BLDG 6 DI EDERLE E' L'IMMAGINE SPECCHIATA DELL'APT
BLDG 5 DI EDERLE. QUESTO DISEGNO SI APPLICA ALL'APT BLDG 6
DI EDELE IN MANIERA SPECCHIATA.I DIEGNI DELL'APT BLDG 6 DI
EDERLE NON SONO INCLUSI NEL SET DI DISEGNI.
GENERAL NOTES /
NOTE GENERALI
• APT BLDGS:
DRY SPRINKLER ZONE IN ACCORDANCE WITH NFPA 13 /
APT BLDGS:
ZONA CON SPRINKLER A SECCO IN CONFORMITA' CON
SPRINKLERS NOT REQUIRED PER NFPA 13:
1. IN CLOSETS LESS THAN 2.2 m2
2. BATHROOMS LESS THAN 5.1 m2
3. OPEN ATTACHED PORCHES /
SRINKLER NOR RICHIESTI COME DA NFPA 13:
1. IN GUARDAROBA PIU' PICCOLI DI 2.2 MQ
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 MQ
3. PORTICATI E/O VERANDE
NO HATCH
\NESSUNA
CAMPITURA
ZC
1.8
1.9
FE FE
1.8
1.9
1.24
FX422
ELEV
CORRMECH
STREET STAIR
COURT STAIR
M BDR
FAM
LAUN
BALC
KIT
DIN
CIRC
BTH 2 FOY
BDR 3BDR 2
M CLS
LIV
STOR
M BDR
FAM
LAUN M BTH
BALC
KIT
DIN
CIRC
BTH 2FOY
BDR 3 BDR 2
M CLS
LIV
STOR
1.27 1.10
1.8 1.28
1.30
MECHCORR
ZC
1.14
FE
1.24
1.8
1.14
FX422
1.29 1.28
1.10
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:100
2M 4M 8M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P E D B
LD
G F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -E
DE
RL
E
AP
T
BL
DG
F O
UR
TH
F
LO
O R
RO
O F
ES
TI
NZ
IO
NE
IN
CE
ND
I-
ED
ER
LE
A
PT
B
LD
G
-Q
UA
RT
O P
IA
NO
T
ET
TO
FX144
CL AK SL
14083476
SCALE: 1 : 1001
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 5 - FOURTH FLOOR /
PLANIMETRIA ESTINZIONE INCENDI - EDERLE
APT BLDG 5 - QUARTO PIANO
SCALE: 1 : 1002
FIRE SUPPRESSION PLAN - EDERLE APT
BLDG 5 - ROOF LEVEL /
PLANIMETRIA ESTINZIONE INCENDI - EDERLE
APT BLDG 5 - LIVELLO TETTO SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
1.8 WET MANUAL STANDPIPE CONNECTION / CONNESSIONE MANUALE
AL SISTEMA DI SCARICO AD ACQUA
1.9 ZONE CONTROL FOR FLOOR / CONTROLLO DI ZONA PER PIANO
1.10 WET PIPE SPRINKLER RISER / MONTANTE DEL SISTEMA SPRINKLER
AD ACQUA
1.14 ZONE CONTROL FOR ELEVATOR MACHINE ROOM / ZONA DI
CONTROLLO DELLA SALA MACCHINE DEGLI ASCENSORI
1.24 PROVIDE FIRE EXTINGUISHER / FORNITURA E POSA IN OPERA DI
ESTINTORE
1.27 STANDPIPE UP AND DOWN/ TUBAZIONE DI SCARICO IN SALITA
SALITA E DISCESA
1.28 STANDPIPE DOWN / TUBAZIONE DI SCARICO IN DISCESA
1.29 PIPE DOWN TO FOURTH FLOOR A / TUBAZIONE IN DISCESA AL
QUARTO PIANO
1.30 PIPE TO ROOF LEVEL SPRINKLER SYSTEM / TUBAZIONE
DELL'IMPIANTO SPRINKLER AL LIVELLO DEL TETTO
GAR
K005
KIT
K009
DIN
K010
LIV
K011 FAM
K002
H-BTH
K003
MECH
K004
FOY
K013
ENT
K001
D
4.2
O
4.1
FE
CLO
K014
DK
K008
STOR
K012
4.3
• OFH OR TH:
SPRINKLE IN ACCORDANCE WITH NFPA 13D. /
OFH O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APARTMENT BUILDINGS:
SPRINKLER IN ACCORDANCE WITH UFC 4-711-01 AND NFPA 13
/ EDIFICI PER APPARTAMENTI: SPRINKLER IN CONFORMITA' A
UFC-4-711-01 E NFPA 13
PROVIDE SPRINKLERS IN STORAGE AREA PER IRC.
1. SPRINKLER DENSITY 2 mm/min. /
FORNIRE SPRINKLER NELLE AREA DI IMMAGAZZINAMENTO
COME DA IRC.
1. DENSITA' DEGLI SPRINKLER 2mm/minuto.
SPRINKLERS NOT REQUIRED PER NFPA 13D:
1. IN CLOSETS LESS THAN 2.2m2
2. BATHROOMS LESS THAN 5.1m2
3. OPEN ATTCHED PORCHED OR GARAGE /
SRINKLER NON RICHIESTI DA NFPA 13D:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 MQ
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 MQ
3. PORTICATI E/O VERANDE
NO HATCH /
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
NESSUNA
CAMPITURA
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. /
VEDI DIESEGNI FAS001-FAS-003 PER LE PLANIMETRIE DI ALLARME
INCENDIO.
2. OFH AND TOWNHOUSE UNITS ARE SHOWN AS TYPICAL. SOME UNITS
ARE MIRRORED AS SHOWN ON THE TYPICAL PLANS. / LE UNITA' OFH
E TOWNHOUSE SONO MOSTRATE COME TIPICHE. ALCUNE UNITA'
SONO SPECCIHATE RISPETTO A COME MOSTRATO SULLE PIANTE
TIPICHE.
GENERAL NOTES /
NOTE GENERALI
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
DES DRW
S Y M
D E S C R
IP
TI
O N
D A
TE
A P P R
DRAWFORM REVISION: 12 APRIL 2018
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
DES PROD DIR
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
A
TL
A
N
TI
C N O
RF
O
LK
VA
FIRE PROTECTION
AS SHOWN
1595974
R. STEPHENS, PE
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
RE
VD
AT
E
N33191-15-D-0811
H
AM
P
TO
N B
LV
D
CCA/MPO
DPS
14 AUG 2020
SEAL
VI
C
EN
ZA
IT
AL
Y
C
AS
ER
M A
ED
ER
LE
P -7
A
R M
Y F
A M
IL
Y
H O
U S
IN
G
PLAN NORTH /
PIANTA NORD
1:50
1M 2M 4M
DPS
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
B
IM
V ic e n za
H o u s in g P V
IL
S F B R F .r vt
FI
RE
S
UP
PR
ES
SI
O
N -O
FH
G
RO
UN
D
FL
O O
R / E
ST
IN
ZI
O
NE
IN
CE
ND
I- O
FH
PI
AN
O
T
ER
RA
FX160
CL AK SL
14083477
SCALE: 1 : 50
FIRE SUPPRESSION - VILLAGGIO OFH -
GROUND FLOOR /
ESTINZIONE INCENDI - VILLAGGIO OFH -
PIANO TERRA
SHEET KEYNOTES: /
NOTE CHIAVE DEL DISEGNO
4.1 PROVIDE WET-PIPE SPRINKLER RISER, AS SHOWN ON DETAIL 1
SHEET FX002. / FORNITURA E POSA IN OPERA DI MONTANTE
TUBAZIONE SPRINKLER AD ACQUA.
4.2 EXTERIOR WALL-MOUNTED WATER MOTOR GONG / CAMPANA
ALIMENTATA AD ACQUA INCENDIO MONTATA A PARETE.
4.3 PROVIDE WALL MOUNTED POST INDICATOR VALVE WITH LOCKING
METHOD. / FORNITURA E POSA IN OPERA INDICATORE DI POSIZIONE
A PARETE CON VALVOLA E CON SISTEMA DI CHIUSURA.
BDR 2
K106
M CLS
K105
M BTH
K103
LAUN
K102
BDR 4
K101
BDR 3
K108
BTH 2
K107
M BDR
K104
CIRC
K100
LIN
K110
LIN
K109
• OFH OR TH:
SPRINKLE IN ACCORDANCE WITH NFPA 13D. /
OFH O TH:
SPRINKLER IN CONFORMITA' CON NFPA 13D
• APARTMENT BUILDINGS:
SPRINKLER IN ACCORDANCE WITH UFC 4-711-01 AND NFPA 13
/ EDIFICI PER APPARTAMENTI: SPRINKLER IN CONFORMITA' A
UFC-4-711-01 E NFPA 13
PROVIDE SPRINKLERS IN STORAGE AREA PER IRC.
1. SPRINKLER DENSITY 2 mm/min. /
FORNIRE SPRINKLER NELLE AREA DI IMMAGAZZINAMENTO
COME DA IRC.
1. DENSITA' DEGLI SPRINKLER 2mm/minuto.
SPRINKLERS NOT REQUIRED PER NFPA 13D:
1. IN CLOSETS LESS THAN 2.2m2
2. BATHROOMS LESS THAN 5.1m2
3. OPEN ATTCHED PORCHED OR GARAGE /
SRINKLER NON RICHIESTI DA NFPA 13D:
1. NEI GUARDAROBA PIU' PICCOLI DI 2.2 MQ
2. STANZE DA BAGNO PIU' PICCOLE DI 5.1 MQ
3. PORTICATI E/O VERANDE
NO HATCH /
FIRE SUPPRESSION HATCHING /
TRATTEGGIO SISTEMA DI SPEGNIMENTO
NESSUNA
CAMPITURA
1. SEE SHEETS FXS001 - FXS003 FOR FIRE SUPPRESSION SITE PLANS. /
VEDI DIESEGNI FAS001-FAS-003 PER LE PLANIMETRIE DI ALLARME
INCENDIO.
2. OFH AND TOWNHOUSE UNITS ARE SHOWN AS TYPICAL. SOME UNITS
ARE MIRRORED AS SHOWN ON THE TYPICAL PLANS. / LE UNITA' OFH
E TOWNHOUSE SONO MOSTRATE COME TIPICHE. ALCUNE UNITA'
SONO SPECCIHATE RISPETTO A COME MOSTRATO SULLE PIANTE
TIPICHE.
GENERAL NOTES /
NOTE GENERALI
SCALE:
GRAPHIC SCALE / SCALA GRAFICA
D E P A R
TM
E N T O F
TH
E
N A V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A V A L F A C
I…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .