Attachment H - 1595974dwg22of43.pdf

PDF 8 MB Posted

Attached to
P-759, FAMILY HOUSING NEW CONSTRUCTION VILLAGGIO SW & CAMP EDERLE NORTH - VICENZA, ITALY
Solicitation number
N62470-20-R-4007
Issued by

About this file

This solicitation is for the construction of new family housing at Villaggio SW and Camp Ederle North in Vicenza, Italy. The Navy is seeking proposals for design-build services including site work, utilities, roads and parking, 140 multi-family housing units in 15 buildings, a community center, playgrounds and open spaces. Proposals are due by July 20, 2020 with award anticipated by September 30, 2020. The period of performance is 730 calendar days for substantial completion. The place of performance is Vicenza, Italy.

View the file

Other files

File Type Posted
Attachment O - ENG-UXO Report Annex1.pdf PDF
Attachment N - Health and Safety Plan.pdf PDF
Attachment P - Demo Bldg As-Built.pdf PDF
N62470-20-R-4007 Amendment 11.pdf PDF
N62470-20-R-4007 Amendment 10.pdf PDF
N62470-20-R-4007 Amendment 9.pdf PDF
N62470-20-R-4007 Amendment 8.pdf PDF
Attachment E - Revised Schedule B Price Proposal Form Dated 8 Dec 2020.pdf PDF
(M) 1595974_Amend0007_spc.pdf PDF
(L) 1595974Amend0007dwg.pdf PDF
N62470-20-R-4007 Amendment 7.pdf PDF
N62470-20-R-4007 Amendment 6.pdf PDF
N62470-20-R-4007 Amendment 5.pdf PDF
(J) Pre-Proposal Conference Presentation.pdf PDF
N62470-20-R-4007 Amendment 4.pdf PDF
(K) Pre-Proposal Conference Attendee Log.pdf PDF
N6247020R4007 Amendment 0003.pdf PDF
N62470-20-R-4007 Amendment 2.pdf PDF
ATTACHMENT I P759 PREPOSALCONFACCESSREQUESTFORM.docx DOCX document
N62470-20-R-4007 Amendment 1.pdf PDF
Attachment H - 1595974dwg27of43.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
N62470-20-R-4007 Solicitation.pdf PDF
Attachment H - 1595974dwg11of43.pdf PDF
Attachment H - 1595974dwg38of43.pdf PDF
AFH JnA.pdf PDF
Attachment H - 1595974dwg21of43.pdf PDF
Attachment H - 1595974dwg5of43.pdf PDF
Attachment H - 1595974dwg16of43.pdf PDF
Attachment H - 1595974dwg28of43.pdf PDF
Attachment H - 1595974dwg33of43.pdf PDF
Attachment H - 1595974dwg15of43.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment H - 1595974dwg43of43.pdf PDF
Attachment H - 1595974dwg9of43.pdf PDF
Attachment H - 1595974dwg4of43.pdf PDF
Attachment H - 1595974dwg12of43.pdf PDF
Attachment H - 1595974dwg10of43.pdf PDF
Attachment H - 1595974dwg13of43.pdf PDF
Attachment H - 1595974dwg18of43.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - 1595974dwg3of43.pdf PDF
Attachment H - 1595974dwg39of43.pdf PDF
Attachment H - 1595974dwg24of43.pdf PDF
Attachment H - 1595974dwg29of43.pdf PDF
Attachment H - 1595974dwg30of43.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment H - 1595974dwg34of43.pdf PDF
Attachment H - 1595974dwg40of43.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T.O.F.

EL -1500

GROUND FL

EL 0

FIRST FL

EL 3400

SECOND FL

EL 6800

THIRD FL

EL 10200

FOURTH FL

EL 13600

GROUND FL A

EL 1700

FIRST FL A

EL 5100

SECOND FL A

EL 8500

THIRD FL A

EL 11900

04 FOURTH

FLOOR A

EL 15300

PENTHOUSE

LEVEL

EL 17000

6 11

OVERALL ROOF

PLAN

EL 20400

SEE SHEET A-521

FOR ELEVATOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER /

VEDERE TAVOLA

A-521 PER REQUISITI

ASCENSORE.

COORDINARE CON

PRODUTTORE.

SUMP PIT/SEE A-521

FOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER /

POZZETTO

SIFONATO/VEDERE

A-521 PER

REQUISITI.

COORDINARE CON

PRODUTTORE.

A3

S-504 OPP

H

G

A2 S-350

SUMP PIT/SEE

A-521FOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER /

POZZETTO

SIFONATO/VEDERE

A-521 PER REQUISITI.

COORDINARE CON

PRODUTTORE.

EQ EQ

FULL DEPTH 10mm STIFFNER PL NS &FS /

ELEMENTO DI IRRIGIDIMENTO A PIENA

PROFONDITÀ 10mm CON PIASTRA

SHIM PL AS REQUIRED /

SPESSORI PIASTRA COME RICHIESTO

ELEVATOR MACHINE BEAM OR

HOIST BEAM. NOTE 2 /

TRAVE DELL' IMPIANTO

MACCHINA DELL'ASCENSORE O

TRAVE DEL PARANCO. NOTA 2

FILL POCKET WITH GROUT AFTER

BEAM INSTALLATION /

RIEMPIRE LA TASCA CON MALTA DOPO

L'INSTALLAZIONE DELLA TRAVE

NOTES: / NOTE:

1. PROVIDE 50⌀ OPENING IN EMBED PLATE

CENTERED IN BETWEEN EACH STUD TO AID GROUT

CONSOLIDATION. /

FORNIRE IN OPERA APERTURE 50 ⌀ DELLA PIASTRA

INCASSATA CENTRATA TRA OGNI PERNO PER

FAVORIRE IL CONSOLIDAMENTO DELLA MALTA

2. SIZE AND LOCATION OF ELEVATOR MACHINE BEAM

AND HOIST BEAM TO BE COORDINATED WITH

ELEVATOR MANUFACTURER, EMBED PLATE SIZE

SHOWN IS PRELIMINARY AND MAY REQUIRE

ADJUSTMENT BASED ON FINAL ELEVATOR

COORDIATION. /

LA DIMENSIONE E LA POSIZIONE DELLA TRAVE

DELL'IMPIANTO MACCHINA ASCENSORE DA

COORDINARE CON IL COSTRUTTORE

DELL'ASCENSORE, LA DIMENSIONE DELLA PIASTRA

MOSTRATA E’ INDICATIVA E PUÒ RICHIEDERE

UN'AGGIUSTAMENTO BASATO SUL COORDINAMENTO

FINALE DELL'ASCENSORE

EMBED PL 13X 140X 300

WITH 20⌀ X 100 HSA (165

GAGE),

UNO NOTE 2 /

INCASSARE PIASTRA 13X

140X 300 CON 20 ⌀ X 100

HSA (MISURA 165),

UNO NOTA 2

SLAB & FRAMING NOTES: /

NOTE SU SOLAI E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES /

FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO.

D. REFER TO SHEET S-601 FOR WALL AND BEAM REINFORCEMENT

SCHEDULES / FARE RIFERIMENTO ALLA TAVOLA S-601 PER

L'ABACO DELLE ARMATURE DELLE PARETI E TRAVI.

E. 250 mm CAST IN PLACE CONCRETE SLAB REINFORCED WITH Ø12

@ 150 O.C EACH WAY TOP AND BOTTOM. SEE PLAN FOR TOP OF

SLAB ELEVATION. /

250 mm GETTO IN CALCESTRUZZO CON SOLETTA ARMATA CON

Ø12 @ OGNI 150 O.C. IN OGNI DIREZIONE IN ALTO E IN BASSO.

VEDERE TAVOLE IN PIANTA PER LE QUOTE DELLA PARTE

SUPERIORE DELLA SOLETTA.

F. REFER TO DETAIL A4 ON SHEET S-502 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A4 SULLA TAVOLA S-502 PER

"IL PROSEGUIMENTO DELLE ARMATURE DELLA TRAVE IN

CALCESTRUZZO AGLI ANGOLI ED INTERSEZIONI"

G. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

H. EDERLE APT BLDG 2 IS AN IDENTICAL MIRROR IMAGE OF

EDERLE APT BUILDING 1. THIS DRAWING APPLIES TO EDERLE

APT BUILDING 2 OPPOSITE HAND. DRAWING SHEETS FOR

EDERLE APT BUILDING 2 ARE NOT INCLUDED. /

EDERLE APT BLDG 2 E' UN'IMMAGINE SPECULARE IDENTICA

A EDERLE APT BLDG 1. QUESTO DISEGNO SI APPLICA A EDERLE

APT BLDG 2 IN MANIERA SPECULARE. I DISEGNI PER EDERLE

APT BLDG 2 NON SONO INCLUSI.

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

H

AM

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:500

10M 20M 40M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

EL

EV

AT

O

R

ST

RU

CT

UR

AL

D

ET

AI

LS

DE

TT

AG

LI

S

TR

UT

TU

RA

LI

A

SC

EN

SO

RE

S-350

SH BDC NJB

14083009

SCALE: 1 : 50A2

ELEVATOR HOISTWAY SECTION /

SEZIONE MONTACARICHI PER ASCENSORI

SCALE: 1 : 50A4

ELEVATOR HOISTWAY PLAN /SEZIONE

MONTACARICHI PER ASCENSORI

SCALE: 1 : 20A1

BEAM POCKET AT CONCRETE WALL /TASCA

SUL MURO DI CEMENTO ARMATO DI

APPOGGIO DELLA TRAVE

7 9

K

M

SUMP PIT-SEE

A-521 FOR REQUIREMENTS.

COOR'D W/ MANUF. /

POZZETTO SIFONATO/VEDERE A-521

PER REQUISITI.

COORDINARE CON PRODUTTORE.

A2

S-351

GROUND FLR B

EL 0

FIRST FL

EL 3400

SECOND FL

EL 6800

THIRD FL

EL 10200

FOURTH FL

EL 13600

TOW

EL 17000

GROUND FL A

EL 1700

FIRST FL A

EL 5100

SECOND FL A

EL 8500

THIRD FL A

EL 11900

TOW A

EL 15300

TOW ROOF WELL

EL 20130

7 9

SEE SHEET A-521

FOR ELEVATOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER /

VEDERE TAVOLA

A-521 PER REQUISITI

ASCENSORE.

COORDINARE CON

PRODUTTORE.

SUMP PIT/SEE A-521

FOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER /

POZZETTO

SIFONATO/VEDERE

A-521

PER REQUISITI.

COORDINARE CON

PRODUTTORE.

PILE CAP

EL -1500

SLAB & FRAMING NOTES: /

NOTE SU SOLAI E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES /

FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO.

D. REFER TO SHEET S-602 FOR WALL AND BEAM REINFORCEMENT

SCHEDULES / FARE RIFERIMENTO ALLA TAVOLA S-602 PER

L'ABACO DELLE ARMATURE DELLE PARETI E TRAVI.

E. 250 mm CAST IN PLACE CONCRETE SLAB REINFORCED WITH Ø12

@ 150 O.C EACH WAY TOP AND BOTTOM. SEE PLAN FOR TOP OF

SLAB ELEVATION. /

250 mm GETTO IN CALCESTRUZZO CON SOLETTA ARMATA CON

Ø12 @ OGNI 150 O.C. IN OGNI DIREZIONE IN ALTO E IN BASSO.

VEDERE TAVOLE IN PIANTA PER LE QUOTE DELLA PARTE

SUPERIORE DELLA SOLETTA.

F. REFER TO DETAIL A4 ON SHEET S-502 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A4 SULLA TAVOLA S-502 PER

"IL PROSEGUIMENTO DELLE ARMATURE DELLA TRAVE IN

CALCESTRUZZO AGLI ANGOLI ED INTERSEZIONI"

G. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

H. EDERLE APT BLDG 4 IS AN IDENTICAL MIRROR IMAGE OF

EDERLE APT BUILDING 3. THIS DRAWING APPLIES TO EDERLE

APT BUILDING 4 OPPOSITE HAND. DRAWING SHEETS FOR

EDERLE APT BUILDING 4 ARE NOT INCLUDED. /

EDERLE APT BLDG 4 E' UN'IMMAGINE SPECULARE IDENTICA

A EDERLE APT BLDG 3. QUESTO DISEGNO SI APPLICA A EDERLE

APT BLDG 4 IN MANIERA SPECULARE. I DISEGNI PER EDERLE

APT BLDG 4 NON SONO INCLUSI.

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:500

10M 20M 40M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

EL

EV

AT

O

R

ST

RU

CT

UR

AL

D

ET

AI

LS

DE

TT

AG

LI

S

TR

UT

TU

RA

LI

A

SC

EN

SO

RE

S-351

SH BDC NJB

14083010

SCALE: 1 : 50A1

ELEVATOR HOISTWAY SECTION / SEZIONE

MONTACARICHI PER ASCENSORI

SCALE: 1 : 50A2

ELEVATOR HOISTWAY SECTION / SEZIONE

MONTACARICHI PER ASCENSORI

6 9

F

G

A2

S-352

SUMP PIT-SEE

A-521 FOR REQUIREMENTS.

COOR'D W/ MANUF. /

FIRST FL

EL 3400

SECOND FL

EL 6800

THIRD FL

EL 10200

FOURTH FL

EL 13600

GROUND FL A

EL 1700

FIRST FL A

EL 5100

SECOND FL A

EL 8500

THIRD FL A

EL 11900

FOURTH FL A

EL 15300

TOW

EL 17000

PENTHOUSE

EL 18700

6 9

T.O.F.

EL -1500

SEE SHEET A-521

FOR ELEVATOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER

/ VEDERE TAVOLA

A-521 PER

REQUISITI

ASCENSORE.

COORDINARE CON

PRODUTTORE.

SUMP PIT/SEE

A-521FOR

REQUIREMENTS.

COORDINATE

W/MANUFACTURER /

POZZETTO

SIFONATO/VEDERE

A-521

PER REQUISITI.

COORDINARE CON

PRODUTTORE.

POZZETTO SIFONATO/VEDERE

A- 521 PER REQUISITI.

COORDINARE CON PRODUTTORE.

SLAB & FRAMING NOTES: /

NOTE SU SOLAI E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES /

FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO.

D. REFER TO SHEET S-603 FOR WALL AND BEAM REINFORCEMENT

SCHEDULES / FARE RIFERIMENTO ALLA TAVOLA S-603 PER

L'ABACO DELLE ARMATURE DELLE PARETI E TRAVI.

E. 250 mm CAST IN PLACE CONCRETE SLAB REINFORCED WITH Ø12

@ 150 O.C EACH WAY TOP AND BOTTOM. SEE PLAN FOR TOP OF

SLAB ELEVATION. /

250 mm GETTO IN CALCESTRUZZO CON SOLETTA ARMATA CON

Ø12 @ OGNI 150 O.C. IN OGNI DIREZIONE IN ALTO E IN BASSO.

VEDERE TAVOLE IN PIANTA PER LE QUOTE DELLA PARTE

SUPERIORE DELLA SOLETTA.

F. REFER TO DETAIL A4 ON SHEET S-502 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A4 SULLA TAVOLA S-502 PER

"IL PROSEGUIMENTO DELLE ARMATURE DELLA TRAVE IN

CALCESTRUZZO AGLI ANGOLI ED INTERSEZIONI"

G. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

H. EDERLE APT BLDG 6 IS AN IDENTICAL MIRROR IMAGE OF

EDERLE APT BUILDING 5. THIS DRAWING APPLIES TO EDERLE

APT BUILDING 6 OPPOSITE HAND. DRAWING SHEETS FOR

EDERLE APT BUILDING 6 ARE NOT INCLUDED. /

EDERLE APT BLDG 6 E' UN'IMMAGINE SPECULARE IDENTICA

A EDERLE APT BLDG 5. QUESTO DISEGNO SI APPLICA A EDERLE

APT BLDG 6 IN MANIERA SPECULARE. I DISEGNI PER EDERLE

APT BLDG 6 NON SONO INCLUSI.

EQ EQ

FULL DEPTH 10mm STIFFNER PL NS &FS /

ELEMENTO DI IRRIGIDIMENTO A PIENA

PROFONDITÀ 10mm CON PIASTRA

SHIM PL AS REQUIRED /

SPESSORI PIASTRA COME RICHIESTO

ELEVATOR MACHINE BEAM OR

HOIST BEAM. NOTE 2 /

TRAVE DELL' IMPIANTO

MACCHINA DELL'ASCENSORE O

TRAVE DEL PARANCO. NOTA 2

FILL POCKET WITH GROUT AFTER

BEAM INSTALLATION /

RIEMPIRE LA TASCA CON MALTA DOPO

L'INSTALLAZIONE DELLA TRAVE

NOTES: / NOTE:

1. PROVIDE 50⌀ OPENING IN EMBED PLATE

CENTERED IN BETWEEN EACH STUD TO AID GROUT

CONSOLIDATION. /

FORNIRE IN OPERA APERTURE 50 ⌀ DELLA PIASTRA

INCASSATA CENTRATA TRA OGNI PERNO PER

FAVORIRE IL CONSOLIDAMENTO DELLA MALTA

2. SIZE AND LOCATION OF ELEVATOR MACHINE BEAM

AND HOIST BEAM TO BE COORDINATED WITH

ELEVATOR MANUFACTURER, EMBED PLATE SIZE

SHOWN IS PRELIMINARY AND MAY REQUIRE

ADJUSTMENT BASED ON FINAL ELEVATOR

COORDIATION. /

LA DIMENSIONE E LA POSIZIONE DELLA TRAVE

DELL'IMPIANTO MACCHINA ASCENSORE DA

COORDINARE CON IL COSTRUTTORE

DELL'ASCENSORE, LA DIMENSIONE DELLA PIASTRA

MOSTRATA E’ INDICATIVA E PUÒ RICHIEDERE

UN'AGGIUSTAMENTO BASATO SUL COORDINAMENTO

FINALE DELL'ASCENSORE

EMBED PL 13X 140X 300

WITH 20⌀ X 100 HSA (165

GAGE),

UNO NOTE 2 /

INCASSARE PIASTRA 13X

140X 300 CON 20 ⌀ X 100

HSA (MISURA 165),

UNO NOTA 2

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:500

10M 20M 40M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

EL

EV

AT

O

R

ST

RU

CT

UR

AL

D

ET

AI

LS

DE

TT

AG

LI

S

TR

UT

TU

RA

LI

A

SC

EN

SO

RE

S-352

SH BDC NJB

14083011

SCALE: 1 : 50A1

ELEVATOR HOISTWAY PLAN / SEZIONE

MONTACARICHI PER ASCENSORI

SCALE: 1 : 75A2

ELEVATOR HOISTWAY SECTION / SEZIONE

MONTACARICHI PER ASCENSORI

SCALE: 1 : 20A4

BEAM POCKET AT CONCRETE WALL /TASCA

HG

A2

S-353

SUMP PIT-SEE A-521

FOR REQUIREMENTS.

COORDINATE W/ MANUF. /

00 T.O.F.

EL -1500

00 GROUND

FLOOR

EL 0

01 FIRST FLOOR

EL 3400

02 SECOND

FLOOR

EL 6800

03 THIRD FLOOR

EL 10200

04 FOURTH

FLOOR B

EL 13600

TOW

EL 17000

HG

SUMP PIT/SEE

A-521 FOR

REQUIREMENTS.

COORDINATE W/

MANUF. /

POZZETTO

SIFONATO/VEDERE

A-521

PER REQUISITI.

COORDINARE CON

PRODUTTORE.

SEE SHEET A-521

FOR ELEVATOR

REQUIREMENTS.

COORDINATE W/

MANUF./ VEDERE

TAVOLA

A-521 PER

REQUISITI

ASCENSORE.

COORDINARE CON

PRODUTTORE.

POZZETTO SIFONATO/VEDERE A- 521 PER

REQUISITI. COORDINARE CON PRODUTTORE.

SLAB & FRAMING NOTES: /

NOTE SU SOLAI E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES / FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE

NOTE GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO.

D. REFER TO SHEET S-611 FOR WALL AND BEAM REINFORCEMENT

SCHEDULES / FARE RIFERIMENTO ALLA TAVOLA S-611 PER

L'ABACO DELLE ARMATURE DELLE PARETI E TRAVI.

E. 250 mm CAST IN PLACE CONCRETE SLAB REINFORCED WITH

Ø12 @ 150 O.C EACH WAY TOP AND BOTTOM. SEE PLAN FOR

TOP OF SLAB ELEVATION. /

250 mm GETTO IN CALCESTRUZZO CON SOLETTA ARMATA CON

Ø12 @ OGNI 150 O.C. IN OGNI DIREZIONE IN ALTO E IN BASSO.

VEDERE TAVOLE IN PIANTA PER LE QUOTE DELLA PARTE

SUPERIORE DELLA SOLETTA.

F. REFER TO DETAIL A4 ON SHEET S-502 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A4 SULLA TAVOLA S-502 PER

"IL PROSEGUIMENTO DELLE ARMATURE DELLA TRAVE IN

CALCESTRUZZO AGLI ANGOLI ED INTERSEZIONI"

G. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

H. VILLAGOP APT BLDG 2 IS AN IDENTICAL MIRROR IMAGE OF

VILLAGIO APT BUILDING 1. THIS DRAWING APPLIES TO VILLAGIO

APT BUILDING 2 OPPOSITE HAND. DRAWING SHEETS FOR

VILLAGIO APT BUILDING 2 ARE NOT INCLUDED. /

VILLAGIO APT BLDG 2 E' UN'IMMAGINE SPECULARE IDENTICA

A VILLAGIO APT BLDG 1. QUESTO DISEGNO SI APPLICA A

VILLAGIO APT BLDG 2 IN MANIERA SPECULARE. I DISEGNI PER

VILLAGIO APT BLDG 2 NON SONO INCLUSI.

EQ EQ

FULL DEPTH 10mm STIFFNER PL NS &FS /

ELEMENTO DI IRRIGIDIMENTO A PIENA

PROFONDITÀ 10mm CON PIASTRA

SHIM PL AS REQUIRED /

SPESSORI PIASTRA COME RICHIESTO

ELEVATOR MACHINE BEAM OR

HOIST BEAM. NOTE 2 /

TRAVE DELL' IMPIANTO

MACCHINA DELL'ASCENSORE O

TRAVE DEL PARANCO. NOTA 2

FILL POCKET WITH GROUT AFTER

BEAM INSTALLATION /

RIEMPIRE LA TASCA CON MALTA DOPO

L'INSTALLAZIONE DELLA TRAVE

NOTES: / NOTE:

1. PROVIDE 50⌀ OPENING IN EMBED PLATE

CENTERED IN BETWEEN EACH STUD TO AID GROUT

CONSOLIDATION. /

FORNIRE IN OPERA APERTURE 50 ⌀ DELLA PIASTRA

INCASSATA CENTRATA TRA OGNI PERNO PER

FAVORIRE IL CONSOLIDAMENTO DELLA MALTA

2. SIZE AND LOCATION OF ELEVATOR MACHINE BEAM

AND HOIST BEAM TO BE COORDINATED WITH

ELEVATOR MANUFACTURER, EMBED PLATE SIZE

SHOWN IS PRELIMINARY AND MAY REQUIRE

ADJUSTMENT BASED ON FINAL ELEVATOR

COORDIATION. /

LA DIMENSIONE E LA POSIZIONE DELLA TRAVE

DELL'IMPIANTO MACCHINA ASCENSORE DA

COORDINARE CON IL COSTRUTTORE

DELL'ASCENSORE, LA DIMENSIONE DELLA PIASTRA

MOSTRATA E’ INDICATIVA E PUÒ RICHIEDERE

UN'AGGIUSTAMENTO BASATO SUL COORDINAMENTO

FINALE DELL'ASCENSORE

EMBED PL 13X 140X 300

WITH 20⌀ X 100 HSA (165

GAGE),

UNO NOTE 2 /

INCASSARE PIASTRA 13X

140X 300 CON 20 ⌀ X 100

HSA (MISURA 165),

UNO NOTA 2

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:500

10M 20M 40M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P V

IL

A P T_ B

LD

G S .r vt

EL

EV

AT

O

R

ST

RU

CT

UR

AL

D

ET

AI

LS

DE

TT

AG

LI

S

TR

UT

TU

RA

LI

A

SC

EN

SO

RE

S-353

SH BDC NJB

14083012

415SCALE: 1 : 50A1

ELEVATOR HOISTWAY PLAN / SEZIONE

MONTACARICHI ASCENSORI

SCALE: 1 : 50A2

ELEVATOR HOISTWAY SECTION / SEZIONE

MONTACARICHI PER ASCENSORI

SCALE: 1 : 20C1

BEAM POCKET AT CONCRETE WALL /TASCA

00 GROUND

FLOOR

EL 0

01 FIRST FL

EL 3360

02 SECOND FL

EL 6780

03 ROOF

EL 10510

CDFHJ

CRAWLSPACE

EL -740

75 200

1400 6050 3100 1200

3.013A

3.013

3.053 3.053

S-507 A2

S-508 B1

S-508 B3

S-507 A2

S-509 A2

S-509 A2

TYP.

TYP.

A3 S-508

TYP

S-508 A1

S-506 A1

SIM

S-507

C2SIM

TYP

O.H.

T.O.F.

EL -1200

3.056 3.056

00 T.O.F.

EL -1200

00 GROUND

FLOOR

EL 0

DJ

CRAWLSPACE

EL -740

10550

3290 7260

3.053 3.039

3.021

3.056

SLAB & FRAMING NOTES: /

NOTE SU SOLETTE E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMANTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES /

FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO

D. 250mm CAST IN PLACE CONCRETE FLOOR SLAB REINFORCED

WITH ⌀12 @ 150 EACH WAY TOP AND BOTTOM. SEE PLAN FOR

SLAB ELEVATION. /

250 mm GETTO IN CALCESTRUZZO CON SOLETTA RINFORZATA

CON Ø12 @ OGNI 150 O.C. IN OGNI DIREZIONE IN ALTO E IN

BASSO. VEDERE TAVOLE IN PIANTA PER LE QUOTE.

E. REFER TO DETAIL 1 ON SHEET S-501 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERS AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO 1 SULLA TAVOLA S-502 PER

“CONTINUITA’ DEI RINFORZI DELLE TRAVI@ ANGOLI &

INTERSEZIONI”.

F. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:50

1M 2M 4M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P V

IL

B

LK

S .r vt

VI

LL

AG

G

IO

T

O W

NH

O

US

E

BL

O

CK

&5 S

EC

TI

O N

/ V

IL

LA

G

G

IO

T H

BL

K

3&

SE

ZI

O

NE

S-360

MC MC VVW

14083013

SCALE: 1 : 50B2

VILLAGGIO TOWNHOME BLOCK 3 AND 5

BUILDING SECTION /

VILLAGGIO TH BLK 3 E 5 SEZIONE EDIFICIO

SHEET KEYNOTES / NOTE CHIAVE DEL DISEGNO

3.013 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON S-508 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA. VEDERE DETTAGLIO 03

3.013A CAST IN PLACE CONCRETE STAIR. SEE S-508 / SCALA IN CALCESTRUZZO

GETTATO IN OPERA. VEDERE S-508 03

3.021 VAPOR BARRIER./BARRIERA DI VAPORE

3.039 200mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB W/ Ø12 BARS @ 300 ON

CENTER EACH WAY CENTERED AT SLAB MID-DEPTH OVER WELL

COMPACTED FILL AND VAPOR RETARDER. PROVIDE THICKENED SLAB EDGE

AT PERIMETER OF SLAB, DOWN TO TOP OF MAT FOUNDATION. / SOLETTA IN

CALCESTRUZZO GETTATA IN OPERA DA MIN 200mm CON FERRI Ø12 a 300 DAL

CENTRO IN TUTTE LE DIREZIONI, CENTRATO IN OGNI DIREZIONE ALLA METÀ

DELLO SPESSORE DELLA SOLETTA POSTA SOPRA AL SOTTOFONDO

COMPATTATO E BARRIERA AL VAPORE. REALIZZARE UN CORDOLO AL

PERIMETRO DEL SOLAIO , FINO ALL'INIZIO DELLA FONDAZIONE A PLATEA.

3.053 13mm PRE-MOULDED JOINT FILLER. / RIEMPIMENTO GIUNTO PERFORMATO DA 13mm.

3.056 100mm CAST-IN-PLACE CONCRETE FLOOR SLAB W/ Ø12 BARS @ 300 ON

CENTER EACH WAY CENTERED AT SLAB MID-DEPTH OVER MODULAR FLOOR

SYSTEM./ SOLETTA IN CALCESTRUZZO GETTATO IN OPERA DA 100 mm

ARMATO CON Ø12 A PASSO 300 O.C. IN TUTTE LE DIREZIONI CENTRATO NEL

MEZZO DELLA PROFONDITÀ DELLA SOLETTA SOPRA AL SISTEMA DI

PAVIMENTAZIONE MODULARE.

SCALE: 1 : 50A2

GARAGE SLAB SECTION /

SEZIONE SOLETTA GARAGE

00 T.O.F.

00 GROUND

FLOOR

EL 0

01 FIRST FLOOR

EL 3400

02 SECOND

FLOOR

EL 6800

03 THIRD FLOOR

EL 10200

04 FOURTH

FLOOR B

EL 13600

05 ROOF A

EL 16830

A H KE

S-505 A1

O.H.

S-505 A3

SIM.

S-509 A2

S-509 A2

TYP.TYP.

S-507 A2

S-507 A1

S-506 B4

S-507 A2

S-506 A4

SIM.

S-507 A3

SIM.

S-509

A2

SIM.

S-506 A1

SIM.

S-508 A1

S-508 B1A3

S-508TYP.

S-508 B3

TYP.

O.H.

SIM.

3.023

3.022

60 60

SIM.

03 THIRD FLOOR

EL 10200

VEDI ABACO MURI

SEE WALL SCHEDULE /

RI

NF

OR

ZO

LA

TE

RA

LE

SP

AN

DR

EL

C/L C/L

VEDI PLANIMETRIA

SEE PLAN

3.015

3.015

600 LAP (TYP)

3.050

3.027

3.063

SLAB & FRAMING NOTES: /

NOTE SU SOLAI E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES /

FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO.

D. 250 mm CAST IN PLACE SLAB REINFORCED WITH ⌀12 @ 150 O.C

EACH WAY TOP AND BOTTOM. SEE PLAN FOR TOP OF SLAB

ELEVATION. /

SOLETTA IN CLS GETTATA IN OPERA ARMATA CON ⌀12 OGNI

150 IN ENTRAMBE LE DIREZIONI SOPRA E SOTTO. VEDERE

TAVOLE IN PIANTA PER LE QUOTE.

E. REFER TO DETAIL A4 ON SHEET S-502 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A4 SULLA TAVOLA S-502 PER

“CONTINUITA’ DEI RINFORZI DELLE TRAVI AGLI ANGOLI &

INTERSEZIONI”.

F. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

G. VILLAGIO APT 2 IS AN IDENTICAL MIRROR IMAGE OF VILLAGIO

APT 1. THIS DRAWING APPLIES TO EDERLE VILLAGIO APT 2

OPPOSITE HAND. DRAWING SHEETS FOR EDERLE VILLAGIO APT

2 ARE NOT INCLUDED. /

VILLAGGIO APT 2 E' UN'IMMAGINE SPECULARE IDENTICA A

VILLAGGIO APT 1. QUESTO DISEGNO SI APPLICA AL

VILLAGGIO APT 2 IN MANIERA SPECULARE. I DISEGNI DEL

VILLAGGIO APT 2 NON SONO INCLUSI.

H. REFER TO SHEET S-611 FOR CONCRETE BEAM SCHEDULE. /

FARE RIFERIMENTO ALLA TAVOLA S-611 PER LA TABELLA DELLE

TRAVI IN CALCESTRUZZO

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:100

2M 4M 8M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P V

IL

A P T_ B

LD

G S .r vt

VI

LL

AG

IO

A

PT

B

LD

G

B

UI

LD

IN

G S

EC

TI

O N

/ V

IL

LA

G

G

IO

B

LD

G

SE

ZI

O

NE

ED

IF

IC

IO

S-380

SH BDC NJB

14083014

SCALE: 1 : 100A1

BUILDING SECTION /

SEZIONE EDIFICIO

SCALE: 1 : 20C1

VILLAGIO APT BLDG WALL SECT 3RD FL 3 BR

BALC / VILLAGIO APT BLDG SEZIONE DEL

MURO AL TERZO PIANO DEL BALCONE 3 BR

SHEET KEYNOTES / NOTE CHIAVE DEL DISEGNO

3.015 Ø12 @ 150 EACH WAY TOP AND BOTTOM/ Ø12 A PASSO 150 IN

TUTTE LE DIREZIONI SIA IN ALTO CHE IN BASSO

3.022 100mm CONCRETE MUD SLAB. / SOLETTA CALCESTRUZZO CONTROTERRA 100mm

3.023 MODULAR FLOOR SYSTEM./SISTEMA DI PAVIMENTO MODULARE

3.027 REFER TO SPANDREL REINFORCING DETAIL./FARE RIFERIMENTO

AL DETTAGLIO DI RINFORZO LATERALE, RINFIANCO

3.050 HOOK SLAB REINFORCING INTO CONCRETE WALL. / AGGANCIARE

LE ARMATURE DEL SOLAIO ALLA PARETE IN CALCESTRUZZO.

3.063 EXTEND BOTTOM BAR REINFORCING TO LAP SPLICE WITH TOP BAR

REINFORCING. / ESTENDERE L’ARMATURA INFERIORE PER

SOVRAPPORLA CON LA SUPERIORE.

00 T.O.F.

00 GROUND

FLOOR

EL 0

01 FIRST FLOOR

EL 3400

02 SECOND

FLOOR

EL 6800

03 THIRD FLOOR

EL 10200

2 1510

S-507 A2

S-507 A2

S-509 A2

TYP.

S-509

A2

TYP.

S-506

A1

TYP.

S-505 A3

TYP.

O.H.

3.023

3.022 A5

S-510

00 T.O.F.

EL -1500

00 GROUND

FLOOR

EL 0

01 FIRST FLOOR

EL 3400

02 SECOND

FLOOR

EL 6800

03 THIRD FLOOR

EL 10200

04 FOURTH

FLOOR B

EL 13600

05 ROOF A

EL 16830

1 6 173 9 16

S-507 A2

S-509 C3

S-505 D3

S-505 A3

SIM.

S-505 A1

TYP.

S-505 A1O.H.

S-505 C1 S-506

A1

TYP.

O.H.

C1 S-380

O.H.

SIM

SLAB & FRAMING NOTES: /

NOTE SU SOLAI E STRUTTURE

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES /

FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL

VENTO.

D. 250 mm CAST IN PLACE SLAB REINFORCED WITH ⌀12 @ 150 O.C

EACH WAY TOP AND BOTTOM. SEE PLAN FOR TOP OF SLAB

ELEVATION. /

SOLETTA IN CLS GETTATA IN OPERA ARMATA CON ⌀12 OGNI

150 IN ENTRAMBE LE DIREZIONI SOPRA E SOTTO. VEDERE

TAVOLE IN PIANTA PER LE QUOTE.

E. REFER TO DETAIL A4 ON SHEET S-502 FOR "CONTINUITY OF

CONCRETE BEAM REINF @ CORNERES AND INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A4 SULLA TAVOLA S-502 PER

“CONTINUITA’ DEI RINFORZI DELLE TRAVI AGLI ANGOLI &

INTERSEZIONI”.

F. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING

DRAWINGS FOR PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

IDRAULICI PER LE PENETRAZIONI NON MOSTRATE.

G. VILLAGIO APT 2 IS AN IDENTICAL MIRROR IMAGE OF VILLAGIO

APT 1. THIS DRAWING APPLIES TO EDERLE VILLAGIO APT 2

OPPOSITE HAND. DRAWING SHEETS FOR EDERLE VILLAGIO APT

2 ARE NOT INCLUDED. /

VILLAGGIO APT 2 E' UN'IMMAGINE SPECULARE IDENTICA A

VILLAGGIO APT 1. QUESTO DISEGNO SI APPLICA AL

VILLAGGIO APT 2 IN MANIERA SPECULARE. I DISEGNI DEL

VILLAGGIO APT 2 NON SONO INCLUSI.

H. REFER TO SHEET S-611 FOR CONCRETE BEAM SCHEDULE. /

FARE RIFERIMENTO ALLA TAVOLA S-611 PER LA TABELLA DELLE

TRAVI IN CALCESTRUZZO

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:100

2M 4M 8M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P V

IL

A P T_ B

LD

G S .r vt

VI

LL

AG

IO

A

PT

B

LD

G

B

UI

LD

IN

G S

EC

TI

O N

/ V

IL

LA

G

G

IO

A

PT

B

LD

G

SE

ZI

O

NE

DE

LL

'E

DI

FI

CI

O

S-381

SH BDC NJB

14083015

SCALE: 1 : 100A1

BUILDING SECTION /

SEZIONE EDIFICIO

SCALE: 1 : 100A3

BUILDING SECTION /

SEZIONE EDIFICIO

SHEET KEYNOTES / NOTE CHIAVE DEL DISEGNO

3.022 100mm CONCRETE MUD SLAB. / SOLETTA CALCESTRUZZO CONTROTERRA 100mm

3.023 MODULAR FLOOR SYSTEM./SISTEMA DI PAVIMENTO MODULARE

GRND FLOOR

EL 0

1ST FLOOR

EL 3420

TOF

EL -1200

ACDH G

1920 5155 6765 3110

SLOPE

/PENDENZA

3.013A

3.013A1 S-506

O.H.

A1 S-506

O.H.

SIM

A1 S-509

SIMA1

S-506

VA

R

IE

S

/ V

AR

IE

A1 S-506

O.H.

SIM

S-507 A4

C1 S-502

3.021

3.039 3.056 3.024A

3.053

3.053

3.060 3.060

T/SLAB EL / T/SOLETTA 4150

T/RIDGE LINE EL. / T/LINEA DI COLMO EL. 9100

SIM

GRND FLOOR

EL 0

TOF

EL -1200

1 63

SLOPE/

PENDENZA

4865 7015

3.024 3.039

3.021

3.053

GRND FLOOR

EL 0

3.013A

3.024A

SLAB NOTES: /

NOTE SUI SOLAI

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES / FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL VENTO.

D. REFER TO DETAIL C3 ON SHEET S-501 FOR "CONTINUITY OF FDN

REINF @ CORNERS & INTERSECTIONS" / FARE RIFERIMENTO AL

DETTAGLIO C3 SULLA TAVOLA S-501 PER “PROSEGUIMENTO DELLE

ARMATURE DI FONDAZIONE AGLI ANGOLI & INTERSEZIONI”.

E. TOP OF SLAB-ON-GRADE ELEVATION IS -170mm (UNO) / LA QUOTA DELL’ESTRADOSSO DELLA SOLETTA A LIVELLO E’ -170mm

(UNO).

F. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS

ADJACENT TO BUILDING / FARE RIFERIMENTO AI DISEGNI CIVILI, PER LE

QUOTE DEI PIANI FINITI ADIACENTI ALL'EDIFICIO.

G. SLAB JOINTS SHOWN ARE SUGGESTED AND MAY BE REVISED AS

REQUIRED. REFER TO DETAILS A4 ON SHEETS S-501 / LE GIUNZIONI DELLE

SOLETTE MOSTRATE SONO SUGGERITE E POSSONO ESSERE RIVISTE A

SECONDA DELLE NECESSITÀ. FARE RIFERIMENTO AL DETTAGLIO A4 SUL

FOGLIO S-501.

H. REFER TO S-490 FOR PILE FOUNDATION PLAN /

FARE RIFERIMENTO AL PIANO DI FONDAZIONE DEL PALO

SCALE:

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

200 400 800

1:10

1:50

1M 2M 4M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P V

IL

S F B R S .r vt

VI

LL

AG

IO

O

FF

IC

ER

H O

US

IN

G B

UI

LD

IN

G

S

EC

TI

O

N / V

IL

LA

G G

IO

A

LL

O

G G

IO

UF

FI

CC

IA

LI

S

EZ

IO

NE

E

DI

FI

CI

O

S-390

SH BDC NJB

14083016

SCALE: 1 : 50B2

VILLAGIO OFFICER HOUSING BUILDING

LONGITUDINAL SECTION /

VILLAGGIO OFH SEZIONE LONGITUDINALE

SHEET KEYNOTES / NOTE CHIAVE DEL DISEGNO

3.013 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON S-508 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA. VEDERE DETTAGLIO 03

3.013A CAST IN PLACE CONCRETE STAIR. SEE S-508 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA. VEDERE S-508 03

3.021 VAPOR BARRIER./BARRIERA DI VAPORE

3.024 CAST IN-PLACE CONCRETE FLOOR SLAB./SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA

3.024A 125mm CAST-IN-PLACE CONCRETE FLOOR SLAB W/ SOLETTA IN

CALESTRUZZO GETTATA IN OPERA SPESSA 125mm.

3.039 200mm (MIN) CAST-IN-PLACE CONCRETE FLOOR SLAB W/ Ø12 BARS

@ 300 ON CENTER EACH WAY CENTERED AT SLAB MID-DEPTH OVER

WELL COMPACTED FILL AND VAPOR RETARDER. PROVIDE

THICKENED SLAB EDGE AT PERIMETER OF SLAB, DOWN TO TOP OF

MAT FOUNDATION. / SOLETTA IN CALCESTRUZZO GETTATA IN

OPERA DA MIN 200mm CON FERRI Ø12 a 300 DAL CENTRO IN TUTTE

LE DIREZIONI, CENTRATO IN OGNI DIREZIONE ALLA METÀ DELLO

SPESSORE DELLA SOLETTA POSTA SOPRA AL SOTTOFONDO

COMPATTATO E BARRIERA AL VAPORE. REALIZZARE UN CORDOLO

AL PERIMETRO DEL SOLAIO , FINO ALL'INIZIO DELLA FONDAZIONE A

PLATEA.

3.053 13mm PRE-MOULDED JOINT FILLER. / RIEMPIMENTO GIUNTO PERFORMATO DA 13mm.

3.056 100mm CAST-IN-PLACE CONCRETE FLOOR SLAB W/ Ø12 BARS @ 300

ON CENTER EACH WAY CENTERED AT SLAB MID-DEPTH OVER

MODULAR FLOOR SYSTEM./ SOLETTA IN CALCESTRUZZO GETTATO

IN OPERA DA 100 mm ARMATO CON Ø12 A PASSO 300 O.C. IN TUTTE

LE DIREZIONI CENTRATO NEL MEZZO DELLA PROFONDITÀ DELLA

SOLETTA SOPRA AL SISTEMA DI PAVIMENTAZIONE MODULARE.

3.060 200mm CAST-IN-PLACE CONCRETE FLOOR SLAB W/ Ø16 TOP AND

BOTTOM BARS, EACH WAY, @ 300 ON CENTER. / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA DA 200mm

SCALE: 1 : 50A1

GARAGE SLAB SECTION /

SEZIONE SOLETTA GARAGE

SCALE: 1 : 10A3

EXTERIOR SLAB SECTION /

SEZIONE SOLETTA ESTERNA

GRND FLOOR

EL 0

1ST FLOOR

EL 3420

TOF

EL -1200

BF E

03.0563.053

TYP

A1 S-506

SIM

T/RIDGE LINE EL. / T/LINEA DI COLMO EL. 9100

3.052

3.042

S-507 A2

S-507 A2

O.H.

3.066

SLAB NOTES: /

NOTE SUI SOLAI

A. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

LA QUOTA DI RIFERIMENTO 0,0 = VEDERE DISEGNI CIVILI

B. REFER TO SHEETS S-001 & S-002 FOR STRUCTURAL GENERAL

NOTES / FARE RIFERIMENTO ALLE TAVOLE S-001 & S-002 PER LE NOTE

GENERALI STRUTTURALI

C. REFER TO SHEET S-003 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLE TAVOLE S-003 PER IL CARICO DEL VENTO.

D. REFER TO DETAIL C3 ON SHEET S-501 FOR "CONTINUITY OF FDN

REINF @ CORNERS & INTERSECTIONS" / FARE RIFERIMENTO AL

DETTAGLIO C3 SULLA TAVOLA S-501 PER “PROSEGUIMENTO DELLE

ARMATURE DI FONDAZIONE AGLI ANGOLI & INTERSEZIONI”.

E. TOP OF SLAB-ON-GRADE ELEVATION IS -170mm (UNO) / LA QUOTA DELL’ESTRADOSSO DELLA SOLETTA A LIVELLO E’ -170mm

(UNO).

F. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS

ADJACENT TO BUILDING / FARE RIFERIMENTO AI DISEGNI CIVILI, PER LE

QUOTE DEI PIANI FINITI ADIACENTI ALL'EDIFICIO.

G. SLAB JOINTS SHOWN ARE SUGGESTED AND MAY BE REVISED AS

REQUIRED. REFER TO DETAILS A4 ON SHEETS S-501 / LE GIUNZIONI DELLE

SOLETTE MOSTRATE SONO SUGGERITE E POSSONO ESSERE RIVISTE A

SECONDA DELLE NECESSITÀ. FARE RIFERIMENTO AL DETTAGLIO A4 SUL

FOGLIO S-501.

H. REFER TO S-490 FOR PILE FOUNDATION PLAN /

FARE RIFERIMENTO AL PIANO DI FONDAZIONE DEL PALO

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

1:50

1M 2M 4M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P V

IL

S F B R S .r vt

VI

LL

AG

IO

O

FF

IC

ER

H O

US

IN

G B

UI

LD

IN

G

S

EC

TI

O

N / V

IL

LA

G G

IO

A

LL

O

G G

IO

UF

FI

CI

AL

I S

EZ

IO

NE

E

DI

FI

CI

O

S-391

SH BDC NJB

14083017

SCALE: 1 : 50A2

VILLAGIO OFFICER HOUSING BUILDING

SECTION / Sezione 1

SHEET KEYNOTES / NOTE CHIAVE DEL DISEGNO

3.042 CONSTRUCTION JOINT. / GIUNTO DI COSTRUZIONE.

3.052 SHORING FOR CONCRETE SLAB SHALL REMAIN IN PLACE UNTIL

CONCRETE WALL ABOVE HAS REACHED FULL STRENGTH. / I

PUNTELLAMENTI DELLE SOLETTE CEMENTIZIE DEVONO RESTARE IN

OPERA FIN QUANDO IL SOPRASTANTE MURO IN CALCESTRUZZO NON

RAGGIUNGE LA PIENA RESISTENZA.

3.053 13mm PRE-MOULDED JOINT FILLER. / RIEMPIMENTO GIUNTO PERFORMATO DA 13mm.

3.056 100mm CAST-IN-PLACE CONCRETE FLOOR SLAB W/ Ø12 BARS @ 300 ON

CENTER EACH WAY CENTERED AT SLAB MID-DEPTH OVER MODULAR

FLOOR SYSTEM./ SOLETTA IN CALCESTRUZZO GETTATO IN OPERA DA 100

mm ARMATO CON Ø12 A PASSO 300 O.C. IN TUTTE LE DIREZIONI

CENTRATO NEL MEZZO DELLA PROFONDITÀ DELLA SOLETTA SOPRA AL

SISTEMA DI PAVIMENTAZIONE MODULARE.

3.066 100mm CAST-IN-PLACE CONCRETE ROOF SLAB W/ Ø12 BOTTOM BARS, EACH WAY, @ 150 ON CENTER. / SOLAIO I COPERTURA IN CALCESTRUZZO

GETTATO IN OPERA DA 100MM ARMATO IN BASSO CON Ø12 , A PASSO 150

O.C.

C3 S-506

A3 S-505

3.096

3.096

A2 S-350

GB-1 GB-1

GB-1

G B-

PC-38

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

W F-

W F-

PC-4A

WF-1800

WF-1800

PC-2A

PC-2B

W F-

A1 S-402

C1 S-402

C2 S-402

A2 S-402

C3 S-402

A1 S-403

A5 S-510

PC-2A

TYP

TYP

C2 S-402

ED APT BLDG 2

TYP

C5 S-510

MIRROR PC-4

FOR EDL APT 2

D1 S-510

TEST PILE / MUCCHIO DI PROVA

CL COLUMN (U.O.N.) IN PLANS /

ASSE DEL PILASTRO (SE NON

DIVERSAMENTE INDICATO) SULLE

PIANTE

REINF. SEE PILE CAP FDN DETAILS

DOWELS SAME SIZE

AND NUMBER AS

COL. VERT. REINF. /

ARMATURA DI RIPRESA

DELLA STESSA

DIMENSIONE E NUMERO

DI ARMATURA DELLA

COLONNA VERTICALE

D

EP

TH

S 1/2 S

TOP OF FOUNDATION.

SEE PLAN /

FILO SUPERIORE DELLA FONDAZIONE

TOP REINFORCING

WHERE INDICATED

/ ARMATURA

SUPERIORE DOVE

INDICATO

LAP - SEE GENERAL

NOTES /

SOVRAPPOSIZIONI -

VEDI NOTE GENERALI

PROVIDE 1/2 S TIE

SPA FROM TOP OF FDN

TO TOP OF S.O.G. /

PREVEDERE STAFFA A 1/2 DI S

DAL FILO SUPERIORE DELLA

FONDAZIONE AL FILO SUPERIORE

DELLA SOLETTA A TERRA

FOUNDATION NOTES: /

NOTE SULLE FONDAZIONI

A. REFER TO DETAIL C3 ON SHEET S-501 FOR "CONTINUITY OF FDN

REINF @ CORNERS & INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO 3 SULLA TAVOLA S-501 PER

"PROSEGUIMENTO DELLE ARMATURE DELLE FONDAZIONI AGLI ANGOLI

ED INTERSEZIONI"

B. REFER TO SHEET S-510 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-510 PER I DETTAGLI TIPOLOGICI

DEI PALI E DEI DADI DI COLLEGAMENTO

C. TOP OF FOUNDATION ELEVATION IS -1500 mm (UNO) / QUOTA ESTRADOSSO FONDAZIONE -1500mm (UNO)

D. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS

ADJACENT TO BUILDING /

FARE RIFERIMENTO AI DISEGNI CIVILI PER I RIALZI SUPERIORI

ADIACENTI ALL'EDIFICIO

E. EDERLE APT BLDG 2 IS AN IDENTICAL MIRROR IMAGE OF EDERLE

APT BUILDING 1. THIS DRAWING APPLIES TO EDERLE APT

BUILDING 2 OPPOSITE HAND. /

EDERLE APT BLDG 2 E' UN'IMMAGINE IDENTICA SPECCHIATA DI

EDERLE APT BLDG 1. QUESTO DISEGNO SI APPLICA A EDERLE APT

BLDG 2 IN MANIERA SPECULARE.

LEGEND: /

LEGENDA

WF-1800 = INDICATES WALL FOUNDATION /

INDICA LA FONDAZIONE DELLA PARETE

=INDICATES WALL FOUNDATION WIDTH /

INDICA LARGHEZZA DELLA FONDAZIONE DELLA PARETE

GB-1 = INDICATES CONCRETE GRADE BEAM. SEE SECTION D1 ON

S-510./

INDICA LA TRAVE DI COLLEGAMENTO IN CLS. VEDI SEZIONE

D1 SCHEDA S-510.

PC-XX = INDICATES PILE CAP FOUNDATION. SEE SHEET S-402 &

S-403 /

INDICA LA SOLETTA IN TESTA ALLA PALIFICATA DI

FONDAZIONE. VEDI SCHEDA S-402 & S-403

= INDICATES 600mm DIAMETER AUGER CAST PILE.

REFER TO DETAILS A3 & D3 ON S-510. /

INDICA 600 mm DIAMETRO PALO TRIVELLATO.

FARE RIFERIMENTO AI DETTAGLI A3 E D3 DELLA SCHEDA S-510

SCALE:

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

PLAN NORTH /

PIANTA NORD

400 800

1:20

1.6M

1:100

2M 4M 8M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

ED

ER

LE

A

PT

B

LD

G

P

IL

E

FO

UN

DA

TI

O N

PL

AN

PI

AN

TA

F O

ND

AZ

IO

NI

S U

PA

LI

S-401

SH BDC NJB

14083018

SHEET KEYNOTES /

NOTE CHIAVE DEL DISEGNO

3.096 300mm x 600mm OPENING THROUGH WALL. BOT OF OPENING 320 mm ABOVE FOUNDATION. / APERTURA ATTRAVERSO PARETE 300mmX600mm. BASE DELL’APERTURA 320mm SOPRA LA FONDAZIONE.

SCALE: 1 : 100

PILE FOUNDATION PLAN /

PIANTA FONDAZIONI SU PALI

SCALE: 1 : 20A1

TYP. CONCRETE COLUMN

FOUNDATION DETAIL /

DETTAGLIO TIPOLOGICO DI FONDAZIONE

DEL PILASTRO IN CEMENTO ARMATO

1800 MIN 1800 MIN

TYPICAL WALL FOUNDATION PILE SPACING @ EDERLE APT. &

VILLAGIO APT BUILDINGS/

TIPOLOGICO INTERASSE PALI SU FONDAZIONE DELLA PARETE

CL

1800 MIN

CL

CL

300 600600 300

6001800

TYPICAL WALL FOUNDATION AT CORNER

PILE SPACING AT EDERLE APT. & VILLAGIO

APT. BUILDINGS / TIPOLOGICO INTERASSE

PALI D'ANGOLO SU FONDAZIONE DELLA

PARETE

750 750

725 775

750 750

1000 mm THICK/ 1000 mm DI SPESSORE

(10)-Ø28 (T2)

(22)-Ø28 (T1)

(10)-Ø28 (B2)

(22)-Ø28 (B1)

1000 mm THICK/ 1000 mm DI SPESSORE

(10)-Ø28 (T2)

(26)-Ø28 (T1)

(10)-Ø28 (B2)

(26)-Ø28 (B1)

750 750

750 750

725 775

600 3400 600

1000 mm THICK / 1000 mm DI SPESSORE

3575 900

(30)-Ø28 (T2)

(23)-Ø28 (T1)

(30)-Ø28 (B2)

(23)-Ø28 (B1)

MIRROR PC-4

FOR EDL APT 2

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

A. REFER TO FOUNDATION PLANS FOR INFORMATION NOT SHOWN HERE.

/ FARE RIFERIMENTO ALLA PIANTA FONDAZIONI PER LE

INFORMAZIONI NON MOSTRATE QUI.

B. REFER TO SHEET S-510 FOR TYPICAL GRADE BEAM, PILE, AND PILE

CAP DETAILS. / FARE RIFERIMENTO ALLA SCHEDA S-510 PER I

DETTAGLI TIPOLOGICI DI TRAVI, PALI, SOLETTA IN TESTA AI PALI

TYPICAL WALL FOUNDATION PILE

SPACING @ VILLAGIO BLOCK 1-5

& OFFICER HOUSING/

TIPOLOGICO INTERASSE PALI SU

FONDAZIONE DELLA PARETE

600 600 600

SE

E

PL

AN

VE

D I P

IA

N

O

EQ

U

AL

S

PA

C

IN

G

SE

E

PL

AN

VE

D I P

IA

AL

S

PA

C

IN

G

SE

E

PL

AN

VE

D I P

IA

AL

S

PA

C

IN

G

SE

E

PL

AN

VE

D I P

IA

AL

S

PA

C

IN

G

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

PLAN NORTH /

PIANTA NORD

1:25

1M 2M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

PI

LE

C

AP

P

LA

N

DE

TA

IL

S / D

ET

TA

G

LI

S O

LE

TT

A

IN

T

ES

TA

A

I P

AL

I

S-402

SH BDC NJB

14083019

SCALE: 1 : 25A1

TYPICAL DETAIL /

DETTAGLIO TIPOLOGICO

SCALE: 1 : 25C1

TYPICAL DETAIL /

DETTAGLIO TIPOLOGICO SCALE: 1 : 25C2

PC-2A PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

SCALE: 1 : 25C3

PC-2B PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

SCALE: 1 : 25A2

PC-4A PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

SCALE: 1 : 25A4

TYPICAL DETAIL /

DETTAGLIO TIPOLOGICO

600 1775 535 1240 1075 700 1775 1775 1775 600

(19)-Ø28 (T2)

(40)-Ø28 (T1)

(31)-Ø28 (B2)

(40)-Ø28 (B1)

3613 8238

(19)-Ø28 (B2)

(31)-Ø28 (T2)

3613 2213 6025

(14)-Ø28 (B1)

(24)-Ø28 (B1)

1000 mm THICK / 1000 mm SPESSORE

(14)-Ø28 (T1)

(24)-Ø28 (T1)

(88)-Ø28 (B2)

(88)-Ø28 (T2)

5825 6025

PROVIDE LAP SPLICE FOR

REINF. BARS OVER 9100 mm

IN LENGTH (TYP)

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

A. REFER TO FOUNDATION PLANS FOR INFORMATION NOT SHOWN HERE.

/ FARE RIFERIMENTO ALLA PIANTA FONDAZIONI PER LE

INFORMAZIONI NON MOSTRATE QUI.

B. REFER TO SHEET S-510 FOR TYPICAL GRADE BEAM, PILE, AND PILE

CAP DETAILS. / FARE RIFERIMENTO ALLA SCHEDA S-510 PER I

DETTAGLI TIPOLOGICI DI TRAVI, PALI, SOLETTA IN TESTA AI PALI

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

PLAN NORTH /

PIANTA NORD

1:50

1M 2M 4M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

PI

LE

C

AP

P

LA

N

DE

TA

IL

S / D

ET

TA

G

LI

S O

LE

TT

A

IN

T

ES

TA

A

I P

AL

I

S-403

SH BDC NJB

14083020

SCALE: 1 : 50A1

PC-38 PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

3.097

3.096

A2

S-351

PC-2C PC-2C

PC-2D

GB-1

GB-1

GB-1

G B-

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

WF-1800

W F-

WF-1800

WF-1800

W F-

C1 S-411

C4 S-411

A2 S-411

A5

S-510

TYP

EDERLE APT BLDG 4

EDERLE APT BLDG 4

A1 S-412

PC-44

A4 S-412

S-402 A1

S-402 C1

PC-4

C5

S-510

TYP

TEST PILE / PALO DI PROVA

FOUNDATION NOTES: /

NOTE SULLE FONDAZIONI

A. REFER TO DETAIL C3 ON SHEET S-501 FOR "CONTINUITY OF FDN

REINF @ CORNERS & INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO C3 SULLA TAVOLA S-501 PER

"PROSEGUIMENTO DELLE ARMATURE DELLE FONDAZIONI AGLI

ANGOLI ED INTERSEZIONI"

B. REFER TO SHEET S-510 FOR TYPICAL PILE AND PILE CAP DETAILS./

FARE RIFERIMENTO ALLA SCHEDA S-510 PER IL TIPLOGICO DEI PALI E

DELLA SOLETTA IN TESTA AI PALI

C. TOP OF FOUNDATION ELEVATION IS -1500 mm (UNO) QUOTA ESTRADOSSO FONDAZIONE -1500mm (UNO)

D. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS

ADJACENT TO BUILDING /

FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE DEL TERRENO

ADIACENTI ALL'EDIFICIO

E. EDERLE APT BLDG 4 IS AN IDENTICAL MIRROR IMAGE OF EDERLE

APT BUILDING 3. THIS DRAWING APPLIES TO EDERLE APT

BUILDING 4 OPPOSITE HAND. / EDERLE APT BLDG 4 E' UN'IMMAGINE

IDENTICA SPECCHIATA DI EDERLE APT BLDG 3. QUESTO DISEGNO SI

APPLICA A EDERLE APT BLDG 4 IN MANIERA SPECULARE.

LEGEND: /

LEGENDA

WF-1800 = INDICATES WALL FOUNDATION /

INDICA LA FONDAZIONE DELLA PARETE

= INDICATES WALL FOUNDATION WIDTH /

INDICA LA LARGHEZZA DELLA

FONDAZIONE DELLA PARETE

GB-1 = INDICATES CONCRETE GRADE BEAM.

SEE SECTION D1 ON S-510. /

INDICA LA TRAVE DICOLLEGAMENTO IN

CLS, VEDI SEZIONE D1 SCHEDA S-510

PC-XX = INDICATES PILE CAP FOUNDATION.

SEE SHEET S-411 & S-412 /

INDICA LA SOLETTA DI TESTA DEI PALI

DI FONDAZIONE.

VEDI SCHEDA S-411 & S-412

= INDICATES 600mm DIAMETER AUGER CAST PILE.

REFER TO DETAILS A3 & D3 ON S-510. /

INDICA IL DIAMETRO DEL PALO TRIVELLATO 600 mm FARE RIFERIMENTO AI DETTAGLI A3 e D3 SCHEDA S-510

CL COLUMN (U.O.N.) IN PLANS /

ASSE DEL PILASTRO (SE NON

DIVERSAMENTE INDICATO)

SULLE PIANTE

REINF. SEE PILE CAP FDN DETAILS /

ARMATURA SOLETTA DI TESTA PALI

FARE RIFERIMENTO AI DETTAGLI

DOWELS SAME SIZE AND NUMBER AS

COL. VERT. REINF. / BARRE DI

RIPRESA DELLA STESSA DIMENSIONE

E NUMERO DI ARMATURA DELLA

COLONNA VERTICALE

D

EP

TH

S

1/2S TOP OF FOUNDATION. SEE PLAN /

ESTRADOSSO DELLA FONDAZIONE.

VEDI PIANTA

TOP REINFORCING

WHERE INDICATED

/ ARMATURA

SUPERIORE DOVE

INDICATO

LAP - SEE GENERAL NOTES /

SOVRAPPOSIZIONE - VEDI

NOTE GENERALI

PROVIDE 1/2 S TIE

SPA FROM TOP OF FDN

TO TOP OF S.O.G. /

PREVEDERE STAFFA A 1/2 DI S

DAL FILO SUPERIORE DELLA

FONDAZIONE AL FILO

SUPERIORE DELLA SOLETTA A

TERRA

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

PLAN NORTH /

PIANTA NORD

1:100

2M 4M 8M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

ED

ER

LE

A

PT

B

LD

G

P

IL

E

FO

UN

DA

TI

O N

PL

AN

PI

AN

TA

P

AL

I D I F

O

ND

AZ

IO

NE

S-410

SH BDC NJB

14083021

SHEET KEYNOTES /

NOTE CHIAVE DEL DISEGNO

3.096 300mm x 600mm OPENING THROUGH WALL. BOT OF OPENING 320 mm ABOVE FOUNDATION. / APERTURA ATTRAVERSO PARETE 300mmX600mm. BASE DELL’APERTURA 320mm SOPRA LA

FONDAZIONE.

3.097 300mm x 600mm OPENING THROUGH WALL. BOT OF OPENING 75 mm ABOVE FOUNDATION. / APERTURA ATTRAVERSO PARETE 300mmX600mm. BASE DELL’APERTURA 75 mm SOPRA LA

FONDAZIONE.

SCALE: 1 : 100

PILE FOUNDATION PLAN /

PIANTA PALI DI FONDAZIONE

SCALE: 1 : 20A3

TYP. CONCRETE COLUMN

FOUNDATION DETAIL /

TIPICO DETTAGLIO DI FONDAZIONE DEL

PILASTRO IN CEMENTO ARMATO

750 750

(10)-Ø28 (T2)

(10)-Ø28 (B2)

(22)-Ø28 (T1)

(22)-Ø28 (B1)

1000 mm THICK / 1000 mm SPESSORE

750 750

(10)-Ø28 (T2)

(10)-Ø28 (B2)

(26)-Ø28 (T1)

(26)-Ø28 (B1)

1000 mm THICK / 1000 mm SPESSORE

600 4226 600

914 3598 914

1000 mm THICK / 1000 mm SPESSORE

(36)-Ø28 (T2)

(36)-Ø28 (B2)

(24)-Ø28 (T1)

(24)-Ø28 (B1)

SCALE:

GRAPHIC SCALE / SCALA GRAFICA

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

DES DRW

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

DRAWFORM REVISION: 12 APRIL 2018

CHK

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

OF

EPROJECT NO.:

PM/DM

BRANCH MANAGER

DES PROD DIR

N A

VA

L

FA

C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A

TL

A

N

TI

C N O R

FO

LK

VA

FIRE PROTECTION

AS SHOWN

1595974

R. STEPHENS, PE

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

RE

VD

AT

E

N33191-15-D-0811

P

TO

N

B

LV

D

CCA/MPO

DPS

14 AUG 2020

SEAL

VI

C

EN

ZA

IT

AL

Y

C

AS

ER

M A

ED

ER

LE

P -7

A

R M

Y F

A M

IL

Y

H O

U S

IN

G

PLAN NORTH /

PIANTA NORD

1:25

1M 2M

JTW

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

GNSS I LANO E

STATE

OF

NO.

42590P

O R

F E

R I N

E E

NI

B.

S.

HASSA

ITI ACR E

R

E

F

C

OL DAI

T F

B

IM

V ic e n za

H o u si n g P E D B

LD

G S .r vt

PI

LE

C

AP

P

LA

N

DE

TA

IL

S / D

ET

TA

G

LI

S O

LE

TT

A

IN

T

ES

TA

A

I P

AL

I

S-411

SH BDC NJB

14083022

SCALE: 1 : 25C1

PC-2C PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

SCALE: 1 : 25C4

PC-2D PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

SCALE: 1 : 25A2

PC-4B PILE CAP DETAIL /

DETTAGLIO SOLETTA IN TESTA AI PALI

A. REFER TO FOUNDATION PLANS FOR INFORMATION NOT

SHOWN HERE. /

FARE RIFERIMENTO ALLA PIANTA FONDAZIONI PER LE

INFORMAZIONI NON MOSTRATE QUI

B. REFER TO SHEET S-510 FOR TYPICAL GRADE BEAM, PILE, AND

PILE CAP DETAILS. /

FARE RIFERIMENTO ALLA SCHEDA S-510 PER I TIPOLOGICI DI

TRAVI, PALI E SOLETTA IN TESTA AI PALI

GENERAL NOTES THIS SHEET:/

NOTE GENERALI DI QUESTO FOGLIO

12454

5°

90°

155°

6001810180018001419600

6001219120912091218

59912091898519

(15)-Ø28 (T1)