This document package includes architectural drawings and specifications for a construction project to expand and renovate an outpatient mental health clinic at the Tomah VA Medical Center in Tomah, Wisconsin. The project involves renovations to approximately 10,000 square feet of existing space on the second and third floors, including new offices, exam rooms, group rooms, waiting areas, and support spaces. It also includes demolition of existing spaces on those floors to accommodate the new construction. The drawings provide floor plans, reflected ceiling plans, elevations, sections, and construction details. Specifications cover finishes, fixtures, equipment requirements, and scope of work. The solicitation is for a fixed-price construction contract to be awarded by the Department of Veterans Affairs.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STEEL STUD (TYP)
GWB (TYP)
MECHANICAL FASTENER (TYP)
ALUMINUM RETAINER (TYP)
HIGH IMPACT VINYL OR PLASTIC
EXTRUSION (TYP)
6"
CUSHION (TYP)
1 63/256"
5/
/1 6"
A F
F
A
F F
LOWER BUMPER
BASE AS SCHEDULED
FLOORING AS SCHEDULED
UPPER BUMPER
6"
1 63/256"
5/
/1 6"
STEEL STUD (TYP)
GWB (TYP)
ADHESIVE (TYP)
HIGH IMPACT VINYL OR PLASTIC
EXTRUSION (TYP)49
A
F F
RESILIENT BASE AS SCHEDULED
(CONFIRM ADHESIVE WITH
MANUFACTURER)
FLOORING AS SCHEDULED
CLEAR SILICONE AT BASE (TYP)
CLEAR SILICONE AT TOP (TYP)
STEEL STUD (TYP)
EDGE TRIM, COLOR TO MATCH
THE PANEL (TYP)
N O
T L
E S
S T
H A
N
A
F F
STEEL STUD (TYP)
GWB (TYP)
ADHESIVE (TYP)
HIGH IMPACT VINYL OR PLASTIC
EXTRUSION (TYP)52
A
F F
COVE BASE AS SCHEDULED
FLOORING AS SCHEDULED
CLEAR SILICONE AT BASE (TYP)
CLEAR SILICONE AT TOP (TYP)
STEEL STUD (TYP)4"
EDGE TRIM, COLOR TO MATCH
THE PANEL (TYP)
EDGE TRIM, COLOR TO MATCH
THE PANEL (TYP)
3"
MECHANICAL FASTENER (TYP)
STEEL STUD (TYP)
CONTINUOUS ALUMINUM RETAINER
GWB
HIGH IMPACT
VINYL OR PLASTIC
EXTRUSION
1/4" RADIUS
GWB
MECHANICAL FASTENER (TYP).
STEEL STUD (TYP)
WALL WIDTH
CONTINUOUS ALUMINUM RETAINER
1/4" RADIUS
HIGH IMPACT VINYL OR
PLASTIC EXTRUSION
3"
STEEL STUD
MECHANICAL
FASTENER (TYP)
16 GA STAINLESS STEEL
GWB
CLEAR SEALANT (TYP)
3 1/2"
16 GA STAINLESS STEEL
GWB
CLEAR SEALANT (TYP)
MECHANICAL FASTENER (TYP).
STEEL STUD (TYP)
1/
2"
WALL WIDTH
EXISTING WALL CONSTUCTION
5/8" GWB
3-5/8" METAL STUD FRAMING
ROLLER SHADE
3/4" PLYWOOD
RESILIENT FLOORING
RESILIENT FLOORING
HEAT WELD SEAM W/
WELDING ROD PER MFR
FLOOR LEVELING FEATHERED OUT
SO FINISH FLOORING IS FLUSH
WITH TOP OF RESLIENT
TRANSITOIN STRIP (TS-1)
CARPET TILE
RESILIENT TRANSITION (TS-1)
RESILIENT FLOORING
FEATHER OUT 36" MIN
FLOOR TILE
(SLOPE 1/4" PER FOOT TO
DRAIN WHERE PRESENT)
SOLID SURFACE
TRANSITION (TS-2)
RESILIENT/CARPET FLOORING
FULL COVERAGE
CRACK ISOLATION
SHEET MEMBRANE
(PER ANSI A118.12)
FLOOR LEVELING FEATHERED
OUT SO FINISH FLOORING IS
FLUSH WITH TOP OF SOLID
SURFACE (TS-2)
THINSET MORTAR
SEALANT TO MATCH
GROUT COLOR
SEALANT
12" MIN
NOTES:
1. TRANSITION TO BE INSTALLED AT DOOR THRESHOLD OF ALL ROOMS WITH FLOOR TILE SCHEDULED.
CARPET TILE
RESILIENT TRANSITION (TS-3)
RESILIENT FLOORING
RESILIENT FLOORING
RESILIENT OR RESINOUS
FLOORING
RESILIENT TRANSITION (TS-4)
RESILIENT FLOORING
SEALED CONCRETE
RESILIENT REDUCER (TS-6)
A R C H I T E C T S E N G I N E E R S
CB
DESIGN
GROUP
Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:
Revisions: Date:
CONSULTANT:
23456789101112131415
B
C
D
E
F
G
H
I
J
123456789101112131415
/8
/4
/8
/2
/4
-1
/2
Drawing of
Architect:
CB DESIGN GROUP, INC.
421 King St., Suite 301 Alexandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213
TOMAH VAMC
TOMAH, WISCONSIN
DECEMBER 15, 2022
676-325
AuthorChecker
EXPAND AND RENOVATE
B404 FOR OUTPATIENT
MENTAL HEALTH
BID SET
INTERIORS FINISHES DETAILS
AF-501
87 250
-3
A F
-5
/1
/2
.p d f
SCALE: 3" = 1'-0"
WALL PROTECTION DETAIL - BUMPER RAIL
SCALE: 3" = 1'-0"
WALL PROTECTION DETAIL - WALL PANEL
(RESILIENT BASE)
SCALE: 3" = 1'-0"
WALL PROTECTION - WALL PANEL (COVE BASE)
SCALE: 3" = 1'-0"
WALL PROTECTION DETAIL - CORNER GUARD
(RESILIENT)
SCALE: 3" = 1'-0"
WALL PROTECTION DETAIL - END WALL
(RESILIENT)
SCALE: 3" = 1'-0"
WALL PROTECTION DETAIL - CORNER GUARD
(STAINLESS STEEL)
SCALE: 3" = 1'-0"
WALL PROTECTION DETAIL - END WALL
(STAINLESS STEEL)
SCALE: 1 1/2" = 1'-0"
TYPICAL ROLLER SHADE
SCALE: 3" = 1'-0"
TRANSITION - RESILIENT TO RESILIENT (HEAT
WELD)
SCALE: 3" = 1'-0"
TRANSITION - RESILIENT TO CARPET
(TS-1-RESILIENT)
SCALE: 3" = 1'-0"
TRANSITION - RESILIENT/CARPET TO TILE
(TS-2-SOLID SURFACE)
SCALE: 3" = 1'-0"
TRANSITION - RESILIENT TO CARPET
(TS-3-RESILIENT)
SCALE: 3" = 1'-0"
TRANSITION - RESILIENT / POURED RESINOUS TO
RESILIENT (TS-4 RESILIENT)
SCALE: 3" = 1'-0"
TRANSITION - RESILIENT TO CONCRETE (TS-6
RESILIENT)
82 of 2332/15/2023 82 of 233
Above finished floor AFF Acoustic ACST Acoustic Panel Ceiling APC Addendum ADD Alternate ALT Aluminum AL Angle L Approximate APPROX Architecture, architectural ARCH Asbestos ASB Asphalt ASPH Assistant ASST Association ASSN Automatic AUTO Average AVG Base plate BP Basement BSMT Beam BM Bearing BRG Bedroom BR Benchmark BM Board BD Boiler BLR Bottom BOT Brick BRK Building line BL Building BLDG Built-up-roof BUR Cabinet CAB Carpet CPT Catalog CAT Ceiling height CH Ceiling CLG Center CTR Centerline CL Ceramic Tile CT Ceramic CER Chalkboard CB Clear CLR Closet CLO Coated CTD Cold rolled CR Column COL Company CO Composition COMP Concrete Masonry Unit CMU Concrete CONC Construction joint CJ Construction CONSTR "Continue, Continuous" CONT Corridor CORR Countersink CSK Cubic CU Curve(d) CRV Dampproofing DP Degree DEG Department(al) DEPT Detail DET Diagonal DIAG Diameter DIA Dimension DIM Dishwasher DW Dispenser DISP Door DR Double DBL Double-hung DH Down DN Downspout DS Drain DR Drawing DWG Each EA East E Electric Water Cooler EWC "Electric, electrical" ELEC Elevation EL Elevator ELEV Engineer ENGR Entrance ENTR Equal EQ Equipment EQUIP Existing To Remain ETR Exhaust EXH Existing EXIST Expansion joint EXP JT Exposed EXP Exterior EXT Fabricate FAB Face of Stud F. OF S.
Fan Coil Unit FCU Fiberglass-reinforced plastics FRP Finish FIN Finished Floor FF Fire Extinguisher FE Fire Extinguisher & Cabinet FEC Fire Retardant Treated FRT Fireproof FPRF Fixture FXTR Flange FLG Flashing FL Floor FL Floor drain FD Flooring FLG Fluorescent FLUOR
Footing FTG Foundation FDN Furnish(ed), furniture FURN Furring FURR Gage (gauge) GA Galvanize(d) GALV Galvanized Iron GALVI Glazed Wall Tile GWT Grab Bar GB Grade GR Gravel GVL Gypsum Wallboard GWB Gypsum GYP Handicapped HC Hardware HDW Heating ventilating and HVAC air conditioning Height HGT High Point HPT High Performance HP High Performance Coating HPC Hollow Metal HM Horizontal HORIZ Include(d), inclusive INCL Incorporated INC Information INFO Inside diameter ID Install(ed), installation INSTL Insulation INSUL Interior INT Janitor JAN Joint JT Joist J, JST Junction box JB Knock down KD Laboratory LAB Lavatory LAV Left Hand LH Left L Length LG Level LVL Light LT Machine MACH Maintenance MAINT Manager MGR Manual MNL Manufacturing MFG Markerboard MB Masonry opening MO Masonry MSNRY Master bedroom MBR Material MATL Maximum MAX Mechanical MECH Membrane MEMB Men M Metal MET, MTL Mezzanine MEZZ Minimum MIN Mirror MIR Miscellaneous MISC Mounted MTD Mounting MTG Necessary NEC Noise-reduction coefficient NRC Nominal NOM Non Combustible NC, NONCOM North N Not in Contract NIC Not to scale NTS Not available NA Number NO Office OFF On center OC Opening OPNG Opposite OPP Outside diameter OD Overall OA Overhead OVHD Page P Painted PTD Pair PR Panel PNL Partition PTN Percent PCT Perforate(d) PERF Permanent PERM Perpendicular PERP Piece PC Plastic Laminate PLAM Plastic Laminate PLAS.LAM Plate PL Plumbing PLMB Plywood PLYWD Point PT Polyvinyl chloride PVC Precast PRCST Prefabricated PREFAB Preliminary PRELIM Preparation, prepare PREP Program PRGM Projection Screen PS
Project PROJ Property PROP Public Address PA Quality control QC Quality QUAL Quantity QTY Quarry Tile QT Radius RAD Rain Leader RL Received RCVD Receptacle RCPT Receptionist RECPT Recess(ed) REC Refer, reference REF Refrigerate, refrigerator REFR Reinforce REINF Reinforced concrete RC Remove RMV Repair RPR Required REQD Revise, revision REV Right hand RH Road RD Roof Drain RD Roof RF Roofing RFG Room RM Rubber tile floor RTF Rubber RBR Schedule SCHED Schematic SCHEM Section SECT Service SVCE "Sheet, sheeting" SHT Shower SH Siding SDG Similar SIM Slope SL Sound-transmission class STC South S Speaker SPKR Specification SPEC Sprinkler SPR Square SQ Stainless steel SS Standard STD Standpipe SP Steel STL Storage STOR Structural Glazed Facing Tile SGFT Structural, structure STRUCT Substitute SUBST Surface SURF Suspend(ed) SUSP Switch SW Symmetrical SYM System SYS Tackboard TB Tackstrip TS Telephone TEL Television TV Temporary TEMP Terrazzo TER Thick THK Through THRU Toilet T Tongue and groove T&G Top and bottom T&B Top chord TC Top of Masonry Parapet TMP Top of Bearing TOFB Top of Steel T.O.S.
Topping TOPG Total TOT Transformer XFMR Transom TR Transparent TRANS Tread TRD Threshold THRESH Typical TYP Underground UG Underwriters Laboratories UL Unfinished UNF Unit Ventilator UV Unless Otherwise Noted UON Urinal UR US Gypsum Company USG Vertical VERT Vestibule VEST, V Vinyl Reducing Strip VRS Vinyl Composite Tile VCT Vinyl asbestos tile VAT Wardrobe WARD Water closet WC Waterproof WP Weight WT Welded WLD Welded Wire Mesh WWM With W/ Without W/O Women W Wood WD Wrought Iron WI
ABBREVIATIONS
A R C H I T E C T S E N G I N E E R S
CB
Drawing Number:
Project Title:
Project Location:
Issue Date
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:
Revisions: Date:
CONSULTANT:
23456789101112131415
B
C
D
E
F
G
H
I
J
123456789101112131415
/8
/4
/8
/2
/4
-1
/2
Drawing of
Architect:
CB DESIGN GROUP, INC.
421 King St., Suite 301 Alexandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213
TOMAH VAMC
TOMAH, WISCONSIN
DECEMBER 15, 2022
676-325
AuthorChecker
EXPAND AND RENOVATE
B404 FOR OUTPATIENT
MENTAL HEALTH
BID SET
ROOM FINISH SCHEDULE
AF-601
88 250
-3
A F
-6
/1
/2
.p d f
ROOM
NUMBER ROOM NAME
Floor Finish
FLOOR WALLS Ceiling Finish NOTESBASE NORTH (A) EAST (D) SOUTH (C) WEST (B)
20460 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-1 PT-7 PT-1 ACT-1
20461 MH CLINIC OFFICE CPT-2 RB-2 PT-0 PT-0 PT-10 PT-0 ACT-1
20462 MH CLINIC OFFICE CPT-2 RB-2 PT-9 PT-1 PT-1 PT-1 ACT-1
20463 MH CLINIC OFFICE CPT-2 RB-2 PT-9 PT-1 PT-1 PT-1 ACT-1
20464 MH CLINIC OFFICE CPT-2 RB-2 PT-0 PT-0 PT-10 PT-0 ACT-1
20466 STAFF TOILET PFT-2 CTB-2 CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A PT-2A
20467 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-1 PT-9 PT-1 ACT-1
20468 MH CLINIC OFFICE CPT-2 RB-2 PT-7 PT-1 PT-1 PT-1 ACT-1
20469 MH CLINIC OFFICE CPT-2 RB-2 PT-10 PT-0 PT-0 PT-0 ACT-1
20470 MH CLINIC OFFICE CPT-2 RB-2 PT-9 PT-1 PT-1 PT-1 ACT-1
20474 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-1 PT-1 PT-3 ACT-1
20475 MH CLINIC OFFICE CPT-2 RB-2 PT-0 PT-10 PT-0 PT-0 ACT-1
20476 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-1 PT-1 PT-9 ACT-1
20477 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-1 PT-1 PT-9 ACT-1
20478 MH CLINIC OFFICE CPT-2 RB-2 PT-0 PT-10 PT-0 PT-0 ACT-1
20479 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-7 PT-1 PT-1 ACT-1
3C03 CORRIDOR CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
3C04 CORRIDOR CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
3C06 CORRIDOR LVT-4 RB-2 PT-1 PT-1 PT-1 PT-6 ACT-1
3C08 CORRIDOR LVT-4 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
3C12 CORRIDOR LVT-4 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
3S1 EAST STAIR ETR ETR ETR ETR ETR ETR ETR
3S2 WEST STAIR ETR ETR ETR ETR ETR ETR ETR
30450 STORAGE CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 PT-1
30456 OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30458 OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30460 OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30461 OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30474 STORAGE CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 PT-1
3C02 CORRIDOR CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
3C05 ELEVATOR LOBBY LVT-4 RB-2 - PT-1 / WP-3 PT-1 PT-1 / WP-3 PT-6
3C07 CORRIDOR LVT-4 RB-2 PT-1 / WPS-3 PT-3 PT-1 / WPS-3 PT-3 ACT-1
3C10 CORRIDOR CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
3C11 CORRIDOR LVT-4 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30401 RRTP OFFICE CPT-3 RB-2 PT-1 PT-1 PT-3 PT-1 ACT-1
30402 RRTP OFFICE CPT-3 RB-2 PT-1 PT-1 PT-10 PT-1 ACT-1
30403 RRTP OFFICE CPT-3 RB-2 PT-10 PT-1 PT-1 PT-1 ACT-1
30404 RRTP OFFICE CPT-3 RB-2 PT-9 PT-1 PT-1 PT-1 ACT-1
30405 STAFF TOILET PFT-3 CTB-2 CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A PT-7A
30406 RRTP OFFICE CPT-3 RB-2 PT-1 PT-1 PT-3 PT-1 ACT-1
30409 ADMIN WAIT CPT-3 RB-2 PT-1 PT-6 PT-1 PT-1 ACT-1 / PT-6
30415 ADMIN RECP. CPT-2 RB-2 - PT-1 PT-1 - ACT-1
30416 BUILDING ELECTRICAL CONC1-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
30417 CHIEF OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-3 ACT-1
30418 ADMIN CONFERENCE CPT-3 RB-2 PT-1 PT-6 PT-1 PT-1 ACT-1
30423 ADMIN CUBICLES CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30426 ADMIN OFFICE CPT-3 RB-2 PT-1 PT-3 PT-1 PT-1 ACT-1
30428 RRTP OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-6 ACT-1
30430 RECP. WORKROOM CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30432 RECEPTION CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1 / PT-6
30436 GROUP ROOM C LVT-5 RB-2 PT-1 PT-1 PT-1 PT-6 ACT-1
30436A STORAGE LVT-5 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30437 GROUP ROOM A LVT-5 RB-2 PT-1 PT-6 PT-1 PT-6 ACT-1
30437A STORAGE LVT-5 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30441 GROUP ROOM B LVT-5 RB-2 PT-1 PT-6 PT-1 PT-6 ACT-1
30441A STORAGE LVT-5 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30442 WAITING CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30443 LOUNGE CPT-3 RB-2 - - PT-6 / VWC-3 - ACT-1
30446 HVAC N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C
30447 GENDER NEUTRAL TOILET PFT-3 CTB-2 CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A PT-7A
30448 FAMILY TOILET PFT-3 CTB-2 CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A PT-7A
30449 GENDER NEUTRAL TOILET PFT-3 CTB-2 CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A PT-7A
30451 BUILDING DATA N.I.C N.I.C PT-1 PT-1 PT-1 PT-1 N.I.C
30452 GENDER NEUTRAL TOILET PFT-3 CTB-2 CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A PT-7A
30453 STAFF BREAK RFT-1 RB-1 PT-0 PT-0A PT-0A PT-0A ACT-2
30457 OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30459 OFFICE CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
30462 HAC ETR ETR ETR ETR ETR ETR ETR
30464 MH CLINIC ADMIN CPT-3 RB-2 PT-1 PT-1 PT-1 PT-3 ACT-1
30465 MH CLINIC OFFICE CPT-3 RB-2 PT-0 PT-0 PT-10 PT-0 ACT-1
30466 MH CLINIC OFFICE CPT-3 RB-2 PT-1 PT-3 PT-1 PT-1 ACT-1
30467 MH CLINIC OFFICE CPT-3 RB-2 PT-3 PT-1 PT-1 PT-1 ACT-1
30468 MH CLINIC OFFICE CPT-2 RB-2 PT-1 PT-1 PT-9 PT-1 ACT-1
30470 MH CLINIC OFFICE CPT-3 RB-2 PT-10 PT-0 PT-0 PT-0 ACT-1
30471 MHICM STORAGE RSF-2 RSFB-2 PT-1 PT-1 PT-1 PT-1 ACT-2
30472 STAFF TOILET PFT-3 CTB-2 CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A CT-2 / PT-7A PT-7A
30473 MHICM MED ROOM RSF-2 RSFB-2 PT-1A PT-1A PT-1A PT-1A ACT-2
30476 MHICM PRIVATE COUNSEL CPT-3 RB-2 PT-7 PT-1 PT-1 PT-1 ACT-1
30478 MHICM PATIENT CARE RSF-2 RSFB-2 PT-1A PT-1A PT-1A PT-1A ACT-2
30479 MHICM CUBICLES CPT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
4S1 EAST STAIR ETR ETR ETR ETR ETR ETR ETR
40401 MECHANICAL CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
ROOM
NUMBER ROOM NAME
Floor Finish
FLOOR WALLS Ceiling Finish NOTESBASE NORTH (A) EAST (D) SOUTH (C) WEST (B)
30418A EVTR CONTROL CLST CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
B0400 CRAWL SPACE ETR - - - - - -
B0403 ELEVATOR PIT CONC-1 - - - - - -
B0405 MECHANICAL ROOM CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
BS1 EAST STAIR ETR ETR ETR ETR ETR ETR -
1C02 CORRIDOR TT-1 TT-1 PT-0 PT-0 PT-0 PT-0 ACT-1
1C04 CORRIDOR CONC-1 / TT-1 RB-1 / TT-1 - PT-0 / WPS-1 PT-0 / WPS-1 PT-0 / WPS-1 ACT-1
1C05 MAIN CORRIDOR TT-1 TT-1 PT-0 / WPS-1 PT-0 / WPS-1 PT-0 / WPS-1 / PT-3 PT-10 / DFP-1 ACT-1
1C06 ELEVATOR LOBBY TT-1 TT-1 - PT-0 / WPS-1 PT-0 PT-0 / WPS-1 PT-10
1C07 CORRIDOR TT-1 TT-1 -- -- -- -- ACT-1
1C08 CORRIDOR TT-1 TT-1 - PT-0 / WPS-1 PT-0 PT-0 / WPS-1 ACT-1
1C10 HALL TT-1 TT-1 PT-0 / WPS-1 PT-0 PT-0 / WPS-1 PT-0 ACT-1
1C11 CORRIDOR TT-1 TT-1 PT-0 PT-0 / WPS-1 - PT-0 / WPS-1 ACT-1
1C12 CORRIDOR TT-1 TT-1 - PT-0 / WPS-1 PT-0 PT-0 / WPS-1 ACT-1
1C20 TRAM WALKWAY ETR ETR ETR ETR ETR ETR ETR
1S1 EAST STAIR ETR ETR ETR ETR ETR ETR -
1S2 WEST STAIR ETR ETR ETR ETR ETR ETR -
10404 RRTP COUNSELOR CPT-1 RB-1 PT-9 PT-0 PT-0 PT-0 ACT-1
10405 RRTP COUNSELOR CPT-1 RB-1 PT-3 PT-0 PT-0 PT-0 ACT-1
10411 MAIN ELECTRICAL CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
10412 EMR CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
10413 ELECTRICAL CLOSET CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
10414 BED BUG ZAPPER RSF-2 RSFB-2 PT-1A PT-1A PT-1A PT-1A ACT-2
10415 STORAGE CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
10415A ELECTRICAL CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 PT-1
10416 RRTP VITALS & LOCKERS RSF-1 RSFB-1 PT-0 PT-0 PT-0 PT-0 ACT-2
10417 RRTP WAITING ETR ETR ETR ETR ETR ETR ACT-1
10418 RRTP TOILET PFT-1 CTB-1 PT-3/ CT-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A
10419 RRTP SECURITY OFFICE RSF-1 RSFB-1 PT-0 PT-0 PT-0 PT-0 ACT-1
10420 ADMIN OFFICE CPT-1 RB-1 PT-0 PT-10 PT-0 PT-0 ACT-1
10424 WAITING CPT-1 RB-1 PT-0 DFP-1 - DFP-1 ACT-1
10425 LOUNGE CPT-1 RB-1 - -- VWC-1 -- ACT-1
10426 RRTP OFFICES ETR ETR ETR ETR ETR ETR ETR
10427 RRTP FOYER TT-1 TT-1 PT-0 PT-0 PT-0 PT-0 ACT-1
10430 GROUP ROOM C LVT-1 RB-1 PT-0 PT-10 PT-0 PT-0 ACT-1
10430A STORAGE LVT-1 RB-1 PT-0 PT-0 PT-0 PT-0 -
10435 GROUP ROOM A LVT-1 RB-1 PT-0 PT-10 PT-0 OP-1 ACT-1 / PT-10
10435A STORAGE LVT-1 RB-1 PT-0 PT-0 PT-0 PT-0 PT-0
10438A STORAGE LVT-1 RB-1 PT-0 PT-0 PT-0 PT-0 PT-0
10440 VESTIBULE MAT-1 MTB-1 PT-1 PT-1 PT-1 PT-1 PT-0
10442 INFO DESK TT-1 TT-1 PT-0 PT-0 PT-0 PT-0 ACT-1
10443 WAITING TT-1 TT-1 PT-0 PL-1 / DFP-1 -- PL-1 / DFP-1 ACT-1
10444 FAMILY TOILET PFT-1 CTB-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A
10445 GENDER NEUTRAL TOILET PFT-1 CTB-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A / CT-1 PT-0A
10446 MOTHERS ROOM RSF-1 RSFB-1 PT-3 PT-0 PT-0 PT-0 ACT-2
10447 GENDER NEUTRAL TOILET PFT-1 CTB-1 CT-1 / PT-0 CT-1 / PT-0 CT-1 / PT-0 CT-1 / PT-0 PT-0
10449 BUILDING DATA N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C
10450 TREATMENT CIRCULATION RSF-1 RB-1 PT-0 - PT-0 PT-0 ACT-1
10451 TREATMENT OBSERVATION RSF-1 RSFB-1 PT-0 PT-0 / WP-1 PT-1 - ACT-1
10452 NURSE STATION RSF-1 RSFB-1 PT-0 -- PT-0 PT-0 ACT-1
10453 TREATMENT OBSERVATION RSF-1 RSFB-1 PT-0 PT-0 / WP-1 PT-0 - ACT-1
10454 SPECIMEN TOILET PFT-1 CTB-1 PTE-1 PTE-1 PTE-1 PTE-1 PT-11
10464 HAC ETR ETR ETR ETR ETR ETR ETR
10465 FAMILY WAITING TT-2 TT-2 PT-0 / DFP-1 PT-0-DFP-1 PT-0 PT-0 ACT-1
10466 WORKROOM CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1
10470 MH CLINIC OFFICE CPT-1 RB-1 PT-10 PT-1 PT-1 PT-1 ACT-1
10471 MH CLINIC OFFICE CPT-1 RB-1 PT-9 PT-1 PT-1 PT-1 ACT-1
10472 MH CLINIC OFFICE CPT-1 RB-1 PT-1 PT-1 PT-9 PT-1 ACT-1
10473 MH CLINIC OFFICE CPT-1 RB-1 PT-3 PT-1 PT-1 PT-1 ACT-1
10474 MH CLINIC MED/SUPPLY RSF-2 RSFB-2 PT-0A PT-0A PT-0A PT-0A ACT-2
10475 MH CLINIC EXAM/VITALS RSF-2 RSFB-2 CT-1 / PT-0A CT-1 / PT-0A CT-1 / PT-0A CT-1 / PT-0A ACT-2
10476 STAFF TOILET PFT-1 CTB-1 PT-1 PT-9 PT-1 PT-1 PT-0
10476A STORAGE CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 PT-0
10477 MH CLINIC OFFICE CPT-1 RB-1 PT-0 PT-0 PTE-3/WP-1 PTE-3/WP-1 ACT-1
10478 MH CLINIC OFFICE (FUTURE EXAM) CPT-1 RB-1 PT-0 PT-0 PT-0 PT-0 ACT-1
10479 MH CLINIC OFFICE CPT-1 RB-1 PT-9 PT-0 PT-0 PT-0 ACT-1
10480 MH CLINIC OFFICE CPT-1 RB-1 PT-3 PT-0 PT-0 PT-0 ACT-1
10484 MH CLINIC TELEMED OFFICE CPT-1 RB-1 PT-0 PT-3 PT-0 PT-0 ACT-1
10485 MH CLINIC OFFICE CPT-1 RB-1 PT-0 PT-0 PT-0 PT-3 ACT-1
10499 RECEIVING ETR ETR ETR ETR ETR ETR ETR
10400 GROUP TESTING CPT-1 RB-1 PT-0 PT-0 PT-0 PT-0 ACT-1
10401 TESTING OFFICE CPT-1 RB-1 PT-0 PT-0 PT-10 PT-0 ACT-1
10422 VENDING TT-1 TT-1 PT-0A PL-0 - DFP-1 PT-0A
10438 GROUP ROOM B LVT-1 RB-1 PT-0 OP-1 PT-0 PT-10 ACT-1 / PT-10
10460 RECEPTION CPT-1 RB-1 PT-0 PL-0 PT-0 PT-0 ACT-1 / PT-10
10486 MH CLINIC TELEMED OFFICE CPT-1 RB-1 PT-0 PT-0 PT-0 PT-9 ACT-1
10487 MH CLINIC OFFICE CPT-1 RB-1 PT-0 PT-0 PT-8 PT-10 ACT-1
10488 MH CLINIC TELEMED OFFICE CPT-1 RB-1 PT-0 PT-10 PT-0 PT-0 ACT-1
10489 MH CLINIC TELEMED OFFICE CPT-1 RB-1 PT-0 PT-3 PT-0 PT-0 ACT-1
2C02 CORRIDOR LVT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
2C03 CORRIDOR LVT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
2C04 CORRIDOR LVT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
2C05 CORRIDOR LVT-2 RB-2 PT-1 / WPS-2 PT-1 PT-1 / WPS-2 / CWC PT-1 / WPS-2 PT-8
2C07 CORRIDOR LVT-2 RB-2 PT-1 PT-1 PT-1 PT-8 ACT-1
2C08 CORRIDOR LVT-2 RB-2 - PT-1 PT-1 PT-1 ACT-1
2C11 CORRIDOR LVT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
2C12 CORRIDOR RSF-1 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
2S1 EAST STAIR ETR ETR ETR ETR ETR ETR ETR
2S2 WEST STAIR ETR ETR ETR ETR ETR ETR ETR
20434 GROUP ROOM B LVT-3 RB-2 PT-1 PT-8 PT-1 PT-8 ACT-1
20446 STORAGE LVT-3 RB-2 PT-1 PT-1 PT-1 PT-1 PT-1
20456 HAC ETR ETR ETR ETR ETR ETR ETR
2C06 ELEVATOR LOBBY LVT-2 RB-2 - PT-1 / WPS-2 PT-1 PT-1 / WPS-2 ACT-1
2C10 CORRIDOR LVT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20401 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-9 PT-1 ACT-1
20402 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-7 PT-1 ACT-1
20403 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-10 PT-1 ACT-1
20404 RRTP COUNSELOR CPT-2 RB-2 PT-9 PT-1 PT-1 PT-1 ACT-1
20405 STAFF TOILET PFT-2 CTB-2 CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A PT-2A
20406 RRTP COUNSELOR CPT-2 RB-2 PT-10 PT-0 PT-0 PT-0 ACT-1
20407 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-7 PT-1 ACT-1
20408 BUILDING ELECTRICAL CONC-1 RB-2 PT-1 PT-1 PT-1 PT-1 -
20409 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-9 PT-1 ACT-1
20410 RRTP COUNSELOR CPT-2 RB-2 PT-7 PT-1 PT-1 PT-1 ACT-1
20411 RRTP COUNSELOR CPT-2 RB-2 PT-10 PT-0 PT-0 PT-0 ACT-1
20415 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-1 PT-7 ACT-1
20416 RRTP COUNSELOR CPT-2 RB-2 PT-0 PT-0 PT-0 PT-10 ACT-1
20417 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-9 PT-1 PT-1 ACT-1
20418 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20419 RRTP COUNSELOR CPT-2 RB-2 PT-0 PT-10 PT-0 PT-0 ACT-1
20420 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-9 PT-1 PT-7 ACT-1
20422 RRTP COUNSELOR CPT-2 RB-2 PT-1 PT-1 PT-1 PT-7 ACT-1
20424 RECP. WORKROOM CPT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20426 RECEPTION CPT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1 / PT-9
20427 WAITING CPT-2 RB-2 - - PT-9 / VWC-2 - ACT-1
20428 GROUP ROOM C LVT-3 RB-2 PT-1 PT-1 PT-1 PT-7 ACT-1
20428A STORAGE LVT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20431 GROUP ROOM A LVT-3 RB-2 PT-1 PT-8 PT-1 PT-8 ACT-1
20431A STORAGE LVT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20434A STORAGE LVT-3 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20440 WAITING CPT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20442 HVAC N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C
20443 GENDER NEUTRAL TOILET PFT-2 CTB-2 CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A PT-2A
20444 FAMILY TOILET PFT-2 CTB-2 CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A PT-2A
20445 GENDER NEUTRAL TOILET PFT-2 CTB-2 CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A PT-2A
20447 BUILDING DATA N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C N.I.C
20448 GENDER NEUTRAL TOILET PFT-2 CTB-2 CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A CT-2 / PT-2A PT-2A
20449 STAFF BREAK RFT-1 RB-1 PT-0A PT-0A PT-0A PT-0A ACT-2
20453 RRTP KITCHEN OFFICE CPT-2 RB-2 PT-1 PT-1 PT-1 PT-1 ACT-1
20454 RRTP TEACHING KITCHEN RFT-1 RB-2 PT-0 PT-0A PT-0A PT-0A ACT-2
20457 MH CLINIC TMS CPT-2 RB-2 CWC-1 CWC-1 PT-1A PT-1A ACT-2
20458 MH CLINIC OFFICE CPT-2 RB-2 PT-7 PT-1 PT-1 PT-1 ACT-1
NOTE:
PLANS ARE ROTATED 180 DEGREES FROM TRUE NORTH AND ALL FINISH SCHEDULES WALL NOTES (NORTH, SOUTH, EAST & WEST)ARE BASED ON PLAN NORTH (AND NOT TRUE NORTH)
83 of 2332/15/2023 83 of 233
D W
Range
A
B
C
D
E
F
H
E.8
C.3
G
1 94 5 876321A 1910 151411 12 13 16 17 187.66.4
A.8
B.9
5.2 11a
A.A
A.9
C.6
2C02
20428
20428A
20427
2C06
20408
20447
20445
20444 20443
20448
20442
20440
2042420405 20478
20466
20454
20457 20453
20476 20474
20464
20462
2046020461
20463
20458
20467
20469 20470
20468
20477 20479 20475
20411 20410
20409
20407 20419
2041720415
20420 2041820416
20403
20401 20402
20404
20406 20422
2C10
20426
2S1 2S2
2C05 2C04
2C03
B L-
4 20456
20446
F1
SDF
S4A
A
NX
ENEN
S4EO
NXC
B2
B 2 B
B
B4
B
B5
B6 R2
R2
R2R2A
B
C
D
E
F
H
E.8
C.3
G
1 94 5 876321A 1910 151411 12 13 16 17 187.66.4
A.8
B.9
5.2 11a
A.A
A.9
C.6
A
A
A
CC
D D
D
B B A
A
A
A A A
A
A
A A A
A
A
A A A
A
A A A A
A
A
A A A
A
A
A C C
C C
C
CC
A
A
A
AA
A
A
A
AAA
A
A
A A
A
A A
A
A
A
A
B
B
T Y
P
T Y
P
B
B
N
KEY PLAN
NEW ADDITION
BID DEDUCT #1: REMOVE 3RD FLOOR ADDITION(THIS BECOMES A ROOF AREA)
• REFER TO SHEET BD102, BD103 & BD104 FOR BID DEDUCT #1 DETAILS
BID DEDUCTS LEGEND
BID DEDUCT #3: BID DEDUCT #2 + REMOVE THIS AREA FROM 3RD FLOOR RENOVATION
• NO DEMOLITION IN THIS AREA AND EXISTING TO REMAIN AND CONTRACTOR SHALL
TIE SERVICES TO EXITING SYSTEMS
BID DEDUCT #4: BID DEDUCT #3 + REMOVE 2ND FLOOR ADDITION
• REFER TO BID DECUT #1 ROOF DETAILS FOR THIS BID DEDUCT (SIMILAR
CONDITION )
BID DEDUCT #2: BID DEDUCT #1 + REMOVE THIS AREA FROM 3RD FLOOR RENOVATION
• NO DEMOLITION IN THIS AREA AND EXISTING TO REMAIN AND CONTRACTOR SHALL TIE
SERVICES TO EXITING SYSTEMS
A
B
C
D
E
F
H
E.8
C.3
G
1 94 5 876321A 10 117.66.4
A.8
B.9
5.2
A.A
A.9
C.6
30409
30436
3C05
30416
30451
30453
30449
30448
30447
30452
30446
30442
30428 30405
3C0730423
LOUNGE
30443
30417
30418
30430
30402
30404
30406
30401
30403
30415
30426
3C02
30432
2HR FIRE BARRIER
EAST STAIR
3S1
3C03
3C06
3C08
30450
F1
A
A
ENEN
NX
NXC
A
B
C
D
E
F
H
E.8
C.3
G
1 94 5 876321A 1910 151411 12 13 16 17 187.66.4
A.8
B.9
5.2 11a
A.A
A.9
C.6
30409
30436
3C05
30416
30451
30453
30449
30448
30447
30452
30446
30442
30428 30405
3C07
30459
30457 30464
30472
3C10 30423
LOUNGE
30443
30417
30418
30476
30471
30478 30473
30479
3C11
30430
30402
30404
30406
30401
30403
30415
30426
3C02
30470
30468
30466 30465
30467
3046230432
EAST STAIR
3S1 3S2
3C03
3C06
3C08
3046130460
30456 30458
30450
30474
F1
A
A
EN EN NX
N
XC
S4EO
S4
19151412 13 16 17 1811a
2HR FIRE BARRIER
A
A A A
A
A
A A A
A
A
A C C
C C
C
CC
A
A
A
AAA
A
A
AAAA
B
B
T Y
P
T Y
P
B
30436
3C05
30453
EN EN
NX
N
XC
1. CONTRACTOR SHALL EXCLUDE THE APPROVED BID DEDUCT AREAS TO ALL TASKS AND ITEMS IN ALL DICIPLINES INCLUDING ARCHITECTURE, MEP AND STRUCTURE AND OTHER ARCHITECTURAL ITEMS AND SHEET LIKE FINISH PLANS, RCP, DOOR
SCHEDULE, DEMOLITION ETC.
2. THERE IS NO BID EXCLUSION AREA ON BASEMENT & FIRST FLOOR
BID EXCLUSIONS TYPICAL NOTES
A R C H I T E C T S E N G I N E E R S
CB
Drawing Number:
Project Title:
Project Location:
Issue Date
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:
Revisions: Date:
CONSULTANT:
23456789101112131415
B
C
D
E
F
G
H
I
J
123456789101112131415
/8
/4
/8
/2
/4
-1
/2
Drawing of
Architect:
CB DESIGN GROUP, INC.
421 King St., Suite 301 Alexandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213
TOMAH VAMC
TOMAH, WISCONSIN
DECEMBER 15, 2022
676-325
AuthorChecker
EXPAND AND RENOVATE
B404 FOR OUTPATIENT
MENTAL HEALTH
BID SET
BID DEDUCTS - FLOOR PLANS
BD-101
89 250
-3
B D
-1
/1
/2
.p d f
SCALE: 1/16" = 1'-0"BD-101
2 BID EXCLUSION - SECOND FLOOR PLAN BID DEDUCT # 4
SCALE: 1/16" = 1'-0"BD-101
3 BID EXCLUSION - THIRD FLOOR PLAN BID DEDUCT #3
SCALE: 1/16" = 1'-0"BD-101
1 BID EXCLUSION - THIRD FLOOR PLAN BID DEDUCT #2
SCALE: 1/16" = 1'-0"BD-101
4 BID EXCLUSION - THIRD FLOOR PLAN - BID DEDUCT # 1
KEYNOTES - BID DEDUCTS PLAN
# DESCRIPTION
B1 TYPICAL: ALL THE EXTERIOR WINDOWS TO BE REPLACED IN THE BID DEDUCT AREA
ALL THE EXTERIOR WINDOWS TO BE REPLACED IN THE BID DEDUCT AREA
B2 WINDOW TO GET REPLACED INSTEAD OF INFILLED.
B3 NEW WINDOW TO BE ADDED (REFER TO WINDOWS SCHEDULE)
B4 REAR WALL OF CLOSET GETS REMOVED. CLOSET EXTENDS TO EXTERIOR WALL. CONTRACTOR SHALL VERIFY IF
CLOSET BECOMES LARGE ENOUGH TO REQUIRE SPRINKLER.
B5 ADD 42” PARAPET AT ROOF LEVEL AT GRID LINE A.9
B6 ROOF DRAIN LOCATION AND SLOPE REMAINS THE SAME AS ROOF PLAN AND THE PARAPET REMAIN THE SAME.
B7 CONTRACTOR SHALL USE 3S2 DOOR TYPE AND HARDWARE FROM SHEET AE602 – THIS DOOR WOULD BE ALARMED ON
AFTER HOURS
B8 CONTRACTOR SHALL USE 3S1 DOOR TYPE AND HARDWARE FROM SHEET AE602 - THIS DOOR WOULD BE ALARMED
AFTER HOURS
KEYNOTES - ROOF PLAN
# DESCRIPTION
R1 ROOF DRAIN AND OVERFLOW DRAIN. SEE DETAIL 2/AE550.
R2 PARAPET WALL TO WRAP ROUND EXTENDED COLUMNS WHICH ARE 4 FT ABOVE FINISHED FLOOR TO ALLOW FOR
CONNECTION OF FUTURE FLOOR. (REFER TO STRUCTURAL DRAWINGS)
R3 FALL PROTECTION ANCHOR: CONTRACTOR SHALL PERFORM A DELEGATED DESIGN TO MEET ALL STRUCTURAL AND
OSHA REQUIREMENTS AND THE DESIGN SHALL BE STAMPED BY THE CONTRACTOR ENGINEERS
84 of 2332/15/2023 84 of 233
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
AE-429
5.2
A.A
A.9
215 SF
GROUP ROOM
C
30436
Option Conflict
ELEVATOR
LOBBY
3C05
71 SF
BUILDING
ELECTRICAL
30416
109 SF
BUILDING
DATA
30451
Option Conflict
STAFF BREAK
30453
78 SF
GENDER
NEUTRAL
TOILET
30449
89 SF
FAMILY
TOILET
30448
73 SF
GENDER
NEUTRAL
TOILET
30447
90 SF
GENDER
NEUTRAL
TOILET
30452
CORRIDOR
3C07
110 SF
OFFICE
30459
FEATURE WALL
DF
LOUNGE
30443
231 SF
ADMIN
CONFERENCE
30418 S6A
S4A
S4AO
2S4H
2S4H
S4A
EAST STAIR
3S1
A
A
A
A
A
AAA
30452
30448
6 30
6A
30416
3S
3C03
CORRIDOR
3C08
S2AO
S2AO
S2AO
S2AO
S2AO
S2AO
S2AO
9"
8'-3 1/4"
NXC
NXC
NXC
2S4H
'-0
DN
S4EO
S4AO
S4A
S4AS4EO
S4EO
S4EO
S4A
S4EO
S4A
S4EO
STORAGE
30450
S6EO
S4A
30450
S4A
F1
TV(N.I.C)
T V
(N .I
.C
T V
(N .I
.C
STORAGE
30436A
1/4" PER 1'-0" TAPERED INSULATION
AND EPDM ROOFING
PARAPET CAP
SLOPE 1/4"
PER FOOT
SLOPE 1/4"
PER FOOT
S
LO
P E
/4
P
E R
F O
O T
S
LO
P E
/4
P
E R
F O
O T
3'-0" 18'-7 1/8" 3'-0" 12'-2"
+3 +3
+2
+3
+3 +3
+2 +2
BD-105
BD-105
BD-105
BD-105
BD-105
SIM
A
ENEN
S4AO
NX
NXC
NX
AA
S4AO
S4AO
NX
S4AOS4A
S4AO
BD-104
R1
R1
R2R2
R
R2
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
5.2
A.A
A.9
AD-130
D
D3
D4
D1
D4
D4
D4
D4
D4
D
D
D
AD130
D4 D4
D4
D4
D4 D4 D4
D4
D4
D4
D4
D3
D3
D
D
D
D
D
D11D5
D5 D1
D5D5
D5D5
D1
D1
D1 D1D11
D1
D1 D1
D5
D5
D
1. ALL WORK SHOWN IS EXISTING TO REMAIN UNLESS NOTED OR INDICATED AS DASHED LINES TO BE REMOVED. THE EXTENT OF DEMOLITION WORK SHALL INCLUDE ALL INCIDENTAL DEMOLITION WORK NECESSARY TO PROPERLY PROVIDE ALL NEW WORK SHOWN AND SPECIFIED, TO INCLUDE MECHANICAL, ELECTRICAL, & PLUMBING ITEMS.
2. DEMOLITION WORK SHOWN IS BASED ON EXISTING DRAWINGS AND INSPECTIONS. THE CONTRACTOR SHALL VISUALLY INSPECT ALL EXISTING CONDITIONS, AND IS RESPONSIBLE FOR PERFORMING THE INDICATED DEMOLITION WORK EVEN
IF ACTUAL CONDITIONS DIFFER FROM THESE SHOWN ON THE DRAWINGS.
3. DEMOLITION CONTRACTOR SHALL COORDINATE WITH NEW WORK SECTIONS FOR ADDITIONAL INFORMATION RELATED
TO EXTENT OF DEMOLITION.
4. REFER TO ALL OTHER DRAWINGS IN THIS SET FOR INCIDENTAL DEMOLITION WORK NOT NOTED ON THE DEMOLITION
PLANS.
5. THE OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGE ITEMS. THE CONTRACTOR SHALL PROPERLY DISPOSE OF
ALL CONSTRUCTION DEBRIS. DO NOT STOCKPILE DEBRIS ON SITE.
6. ITEMS TO BE DEMOLISHED SHALL BE REMOVED COMPLETELY INCLUDING ALL ANCHORS, HANGERS, FASTENERS, PIPES, CONDUCTS, DUCTS, ETC. UNLESS OTHERWISE INDICATED TO BE ABANDONED IN PLACE.
7. CONC. SLAB PATCHES MUST BE FLUSH WITH REMAINING SURFACES TO PERMIT APPLICATION OF FINISHES. PROVIDE
WELDED WIRE MESH IN PATCH AREAS LARGER THAT (4) FOUR SQUARE FEET.
8. CONC. SLABS TO REMAIN SHALL BE PATCHED, SCRAPED, LEVELED, AND CLEANED TO PROVIDE SURFACE SUITABLE FOR NEW FINISHES. WHERE RENOVATED AREAS ARE RECEIVING NEW UNDERGROUND MECHANICAL, PLUMBING, ELECTRICAL, OR ADDITIONAL FOUNDATION WORK, SEE MECHANICAL, PLUMBING, ELECTRIC, AND STRUCTURAL DRAWINGS, AS WELL AS ARCHITECTURAL DRAWINGS TO DETERMINE EXTENT OF REQUIRED CUT AND PATCH OF EXISTING SLAB. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL CONC. SLAB DEMOLITION AND REPLACEMENT NECESSARY TO INSTALL THE NEW WORK. BACKFILL ALL BELOW GRADE DEMOLITION WORK WITH SUITABLE FILL
MEETING STRUCTURAL REQUIREMENTS FOR NEW WORK.
9. PARTITIONS SHOWN TO BE REMOVED SHALL BE CONFIRMED BY THE CONTRACTOR AS TO TYPE OF PARTITION AND EXACT LOCATION. COMPLETELY REMOVE PARTITIONS FROM FLOOR TO STRUCTURE ABOVE INCLUDING BASE, ALL FASTENERS, GROUTS, SEAL ANTS, ETC., UNLESS NOTED OTHERWISE. MASONRY PARTITIONS WHICH EXTEND THROUGH THE SLAB SHALL BE REMOVED TO 8" BELOW FINISH FLOOR. FILL SLAB OPENING WITH CONCRETE FILL TO RECEIVE FINISH FLOOR. WHERE WALLS SCHEDULED TO BE REMOVED SIT ON SLABS, GRIND SLAB TO RECEIVE FINISH FLOOR.
10. REMOVE, PATCH AND REPAIR PORTIONS OF WALL PARTITIONS WHICH CONFLICT WITH NEW WORK TO BE INSTALLED, EVEN IF NOT SPECIFICALLY NOTED TO BE DEMOLISHED ON PLANS.
11. WALLS TO BE REMOVED FROM INTERSECTING WALLS SHALL INCLUDE TOOTHED IN REPLACEMENT OF DAMAGED MASONRY ON WALL TO REMAIN AND REMOVAL OF TIES PROJECTING FROM WALLS. SEE DETAILS FOR ADDITIONAL
CONDITIONS.
12. WALLS TO BE PARTIALLY REMOVED SHALL BE TERMINATED WITH FINISHED MASONRY ENDS BY TOOTHING IN NEW MASONRY UNITS, TO MATCH ADJACENT MASONRY. SEE DETAILS FOR OTHER CONDITIONS. NO WALLS SHALL BE
TERMINATED WITH EXPOSED OPEN CELLS OR DAMAGED MASONRY UNITS.
13. WHERE NEW OPENINGS ARE SHOWN IN EXISTING WALLS, CAREFULLY REMOVE MASONRY TO NEAREST JOINT LINE WITHOUT DISTURBING ADJACENT WORK SO THAT NEW WORK CAN BE PATCHED IN TO MATCH. ALL NEW MASONRY
WORK SHALL BE TOOTHED IN.
14. ALL EXISTING STRUCTURE SHALL REMAIN, UNLESS NOTED OTHERWISE.
15. COORDINATE DEMOLITION OF ALL STRUCTURAL ITEMS (COLUMNS, BEAMS, SLABS, ET, ETC.) WITH STRUCTURAL DWGS.
EXTENT OF DEMOLITION AREA SHALL BE IN ACCORDANCE WITH STRUCTURAL REQUIREMENTS AND COORDINATED WITH
ALL NEW WORK.
16. TEMPORARILY SUPPORT ALL BEAMS, LINTELS, PORTIONS OF WALLS ETC., TO BE DISTURBED BY DEMOLITION WORK, UNTIL THEY ARE RE-SUPPORTED BY NEW WORK.
17. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE INTEGRITY OF EXISTING BUILDING ELEMENTS TO REMAIN THROUGHOUT SEQUENCE OF WORK. ANY DAMAGE TO EXISTING BUILDING CONDITIONS SHOWN TO REMAIN SHALL BE
RESTORED TO NEW WORK CONDITION AT NO ADDITIONAL COST TO THE OWNER.
18. WINDOWS SCHEDULED FOR REMOVAL SHALL BE REMOVED COMPLETELY. FASTENERS MAY BE CUT FLUSH WITH HEAD, JAMBS, AND SILLS IF THE NEW WINDOW UNIT WILL CONCEAL FASTENER. PROTECT EXISTING SILLS SCHEDULED TO REMAIN. ALL EXISTING WINDOW OPENINGS MUST BE FIELD MEASURED PRIOR TO SUBMITTAL OF SHOP DRAWINGS.
19. WERE FINISHES ARE INDICATED TO BE REMOVED, REMOVAL SHALL INCLUDE ANY GROUT, ADHESIVES, FASTENERS, AND
ALL OTHER ITEMS USED TO ATTACH THE FINISHES TO THE SURFACES THAT THEY COVER.
20. ANY FLOOR AREAS DAMAGED BY THE DEMOLITION CONTRACTOR SHALL BE PATCHED TO MATCH EXISTING.
21. WHERE CEILINGS ARE TO BE REMOVED, REMOVE ALL CEILINGS SYSTEMS COMPLETE INCLUDING GRID, TRIM HANGER, CLIPS, ETC. WHERE NEW CEILINGS ARE SPECIFIED, NO DOUBLE CEILINGS PERMITTED. REMOVE ALL ORIGINAL
CONCEALED CEILINGS WHERE ENCOUNTERED.
22. ALL EXISTING SURFACES TO REMAIN SHALL BE PROTECTED, PATCHED IF DAMAGED AND CLEANED PRIOR TO
APPLICATION OF FINISHES.
23. CONTRACTOR TO PROTECT ALL EQUIPMENT AND OTHER ELEMENTS IN AREA OF NEW OR DEMOLITION WORK.
24. REMOVE ALL CURTAINS AND BLINDS IN AREAS OF RENOVATION OR DEMOLITION, UNLESS NOTED OTHERWISE.
25. REMOVE MECHANICAL, ELECTRICAL AND PLUMBING ITEMS AS NOTED ON MECHANICAL, ELECTRICAL AND PLUMBING
PLANS. COORDINATE WITH CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING, FOR ADDITIONAL DEMOLITION NOTES. REMOVAL WORK IS INTENDED TO INCLUDE ALL ASSOCIATED ITEMS SUCH AS ELECTRICAL OUTLETS, SWITCHES, CONDUITS, CONTROLS, PIPING, MOUNTING BLOCKS, ETC., AS NOTED. THE CONTRACTOR SHALL REFER TO ALL CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND SPECIFICATIONS FOR PROCEDURES CONCERNING RELATED TRADES IN AREAS WHICH REQUIRE DEMOLITION. REPAIR AND PATCH ANY AREAS
DAMAGED DURING REMOVAL WORK.
26. ASBESTOS CONTAINING MATERIALS (ACM) MAY BE PRESENT IN DEMOLISHED MATERIALS. CONTRACTOR TO PROVIDE TESTING AND REMEDIATE ANY MATERIAL FOUND IN SCOPE OF WORK AREA. IF ACM OR OTHER HAZARDOUS MATERIALS ARE FOUND IN PROJECT AREA AND ARE DISTURBED BY CONSTRUCTION ACTIVITY STOP WORK IMMEDIATELY AND
CONTACT THE COR FOR THE PROJECT.
GENERAL NOTES - DEMOLITION
DOOR TO BE REMOVED
CONSTRUCTION TO BE REMOVED
CONSTRUCTION TO REMAIN
DEMOLITION LEGEND
AREA NOT INCLUDED IN SCOPE
1 HOUR FIRE BARRIER. REFER TO LIFE SAFETY PLAN FOR INFORMATION
LEGEND
2 HOUR FIRE BARRIER. REFER TO LIFE SAFETY PLAN FOR INFORMATION
SMOKE PARTITION. REFER TO LIFE SAFETY PLAN FOR INFORMATION
FEC RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER
FE FIRE EXTINGUISHER ON WALL MOUNTED BRACKET
1. REFER TO SHEET AE521 FOR WALL TYPES AS REFERENCED ON PLANS WITH THE DIAMOND SYMBOL.
2. TYPICAL GYPSUM BOARDS/STUD WALL PARTITION TO BE TYPE S4A UNLESS INDICATED OTHERWISE BY WALL TYPE
SYMBOLS, WALL SECTIONS OR OTHER DETAILS.
3. TYPICAL GYPSUM BOARD CHASE WALLS TO BE TYPE S4AO UNLESS INDICATED OTHERWISE BY WALL TYPE
SYMBOLS, WALL SECTIONS OR OTHER DETAILS.
4. UNLESS NOTED OTHERWISE, WALLS MUST EXTEND TO THE ROOF OR FLOOR DECK ABOVE AND BE SEALED IN
ACCORDANCE WITH THE WALL TERMINATION DETAILS. REFER TO THE CODE STUDY PLAN FOR IDENTIFICATION OF ALL SMOKE AND FIRE WALL CONDITIONS. PERIMETER CORRIDOR AND LOBBY WALLS MUST BE BUILT TO RESIST
THE PASSAGE OF SMOKE.
5. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF MASONRY TO FACE OF
GYPSUM BOARD OR FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
6. COLUMN GRID LINES ARE FOR REFERENCE ONLY, REFER TO STRUCTURAL DRAWINGS FOR COLUMN LOCATIONS.
7. FEC - INDICATES A FIRE EXTINGUISHER WITH A RECESSED CABINET. FE - INDICATES A FIRE EXTINGUISHER WITH A
WALL MOUNTING BRACKET.
8. UNLESS SPECIFICALLY INDICATED OTHERWISE, THE SAME WALL TYPE NEXT TO A DOOR OR OPENING TO
CONTINUE OVER THE DOOR OR OPENING.
9. PLAN LOCATION OF DOORS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS DIAGRAMMATIC ONLY. REFER
TO THE REFERENCED JAMB AND HEAD CONDITION DETAILS TO DETERMINE ACTUAL PLACEMENT OF DOOR AND
FRAME.
10. PLAN DIMENSIONS ARE FROM FACE OF PARTITION TYPE AND DO NOT INCLUDE APPLIED FINISHES, UNLESS NOTED OTHERWISE. PLAN DIMENSIONS INDICATED AS "HOLD" OR "CLEAR" DIMENSIONS ARE FROM FACE OF APPLIED
FINISH.
11. INSTALL WORK STRAIGHT, PLUMB, LEVEL, SQUARE, AND TRUE, IN PROPER ALIGNMENT.
12. FLATNESS: LEVEL FLOORS TO TRUE PLANE WITHIN 1/4 INCH (6 MM) IN 10'-0" (3 M) WHEN TESTED BY TEN FOOT (3 M)
STRAIGHTEDGE PLACED ANYWHERE ON FLOOR IN ANY DIRECTION.
13. BEFORE PROCEEDING WITH PARTITION FRAMING, PROVIDE LAYOUT MARKINGS OF PARTITIONS AND ASSOCIATED IN-WALL ELECTRICAL DEVICES ON SUBFLOOR FOR REVIEW BY ARCHITECT. BEFORE PROCEEDING WITH PARTITION FRAMING, PROVIDE LAYOUT MARKINGS OF PARTITIONS AND ASSOCIATED IN-WALL ELECTRICAL DEVICES ON
SUBFLOOR FOR REVIEW BY ARCHITECT.
14. COORDINATE FURNITURE-RELATED ELECTRICAL LAYOUT WITH FURNITURE VENDOR.
15. WHERE HANDRAILS, GRAB BARS, CABINETS, WALL-MOUNTED DOOR STOPS, OR OTHER WALL-HUNG ITEMS ARE
ATTACHED TO PARTITIONS, INSTALL BACKER PLATES [OR WOOD BLOCKING ] ACCURATELY POSITIONED AND FIRMLY SECURED TO METAL STUDS, WHETHER OR NOT SUCH BACKER PLATES OR BLOCKING ARE INDICATED ON
DRAWINGS.
16. WHERE NEW WORK ABUTS, ALIGNS OR ADJOINS EXISITING MATERIALS, MAKE SMOOTH AND EVEN TRANSITION AND ELIMINATE EVIDENCE OF PATCHING AND REFINISHING. FINISH NEW WORK TO MATCH ADJACENT UNDISTURBED
SURFACES, UNLESS NOTED OTHERWISE.
17. CLOSE AND PATCH HOLES AND OPENINGS IN EXISTING FLOOR, WALL AND CEILING WHICH EXIST OR RESULT FROM
DEMOLITION OR ALTERATION WORK TO MATCH ADJACENT UNDISTURBED SURFACES.
18. PRIOR TO CONCEALMENT OF FIRE RESISTIVE MATERIALS BY OTHER WORK, PATCH AND REPAIR AREAS OF REMOVED OR DAMAGED APPLIED FIREPROOFING. COMPLETE PATCHING AND REPAIR TO MAINTAIN EXISTING FIRE- RESISTANCE DESIGN IN ACCORDANCE WITH FIREPROOFING MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CONDITIONS OF EXPOSURE AND INTENDED USE. COORDINATE TESTING AND INSPECTION OF ASSEMBLIES AS
REQUIRED BY AUTHORITIES HAVING JURISDICTION.
19. PROVIDE FIRESTOPPING OF PENETRATIONS AND VOIDS THROUGH FIRE-RATED WALL, FLOOR AND PARTITION ASSEMBLIES [AND ROOF] INCLUDING EMPTY OPENINGS AND OPENINGS CONTAINING CABLES, PIPES, DUCTS, CONDUIT AND OTHER ELEMENTS.
20. AT SOUND-RATED PARTITION WALLS, PROVIDE CONTINUOUS BEAD OF ACOUSTICAL SEALANT AT AT JUNCTURE OF BOTH FACES OF RUNNERS OR PLATES WITH FLOOR AND CEILING CONSTRUCTION, AND WHEREVER GYPSUM
BOARD ABUTS DISSIMILAR MATERIALS.
• AT OPENINGS AND CUTOUTS, FILL OPEN SPACES BETWEEN GYPSUM BOARD AND FIXTURES, CABINETS, DUCTS AND OTHER FLUSH OR PENETRATING ITEMS, WITH CONTINUOUS BEAD OF SEALANT.
• SEAL SIDES AND BACKS OF ELECTRICAL BOXES TO COMPLETELY CLOSE OFF OPENINGS AND JOINTS.
21. BL- # REFER TO BORROWED LIGHT SCHEDULE ON AE610.
GENERAL NOTES - FLOOR PLAN
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
5.2
A.A
A.9
AD-130
REMOVE EXISTING STONE CORNICE TO EXTENT REQUIRED TO INSTALL NEW
CONSTRUCTION. SEE BID DEDUCT #1 ARCHITECTURAL NEW WORK
EXISTING SHEATHING AND JOISTS TO REMAIN. NEW OPENINGS TO BE CUT
WHERE SHOWN ON SEE BID DEDUCT #1 NEW WORK PLAN.
REMOVE EXISTING DORMER AND STRUCTURE TO EXTENT REQUIRED TO
INSTALL NEW CONSTRUCTION. SEE ARCHITECTURAL AND STRUCTURAL NEW
WORK
DETAIL
2/AE506
DETAIL
2/AE506
DETAIL
2/AE506
EXISTING JOISTS AND
SHEATHING TO REMAIN.
CAREFULLY REMOVE
EXISTING LOUVER
COORDINATE WITH BID
DEDUCT #1 NEW PLANS
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
5.2
A.A
A.9
REMOVE EXISTING STONE CORNICE TO EXTENT
REQUIRED TO INSTALL NEW CONSTRUCTION. SEE
SEE BID DEDUCT #1 ARCHITECTURAL NEW WORK
REMOVE EXISTING ROOFING TO EXTENT REQUIRED
TO INSTALL NEW CONSTRUCTION. SEE
ARCHITECTURAL AND STRUCTURAL FOR NEW WORK
DETAIL
2AE506
DETAIL
2/AE506
DETAIL
2/AE506
REMOVE EXISTING DORMER AND STRUCTURE TO
EXTEND REQUIRED TO INSTALL NEW
CONSTRUCTION. SEE ARCHITECTURAL AND
STRUCTURAL NEW WORK
N
KEY PLAN(BID DEDUCT 1)
NEW ADDITION
A R C H I T E C T S E N G I N E E R S
CB
Drawing Number:
Project Title:
Project Location:
Issue Date
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:
Revisions: Date:
CONSULTANT:
23456789101112131415
B
C
D
E
F
G
H
I
J
123456789101112131415
/8
/4
/8
/2
/4
-1
/2
Drawing of
Architect:
CB DESIGN GROUP, INC.
421 King St., Suite 301 Alexandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213
TOMAH VAMC
TOMAH, WISCONSIN
DECEMBER 15, 2022
676-325
AuthorChecker
EXPAND AND RENOVATE
B404 FOR OUTPATIENT
MENTAL HEALTH
BID SET
FLOOR PLANS - BID DEDUCT 1
BD-102
90 250
-3
B D
-1
/1
/2
.p d f
SCALE: 1/8" = 1'-0"
THIRD FLOOR PLAN BID DEDUCT #1
SCALE: 1/8" = 1'-0"
THIRD FLOOR DEMO PLAN BID DEDUCT 1
KEYNOTES - DEMOLITION PLAN
# DESCRIPTION
D1 REMOVE EXISTING STONE BELT TO EXTENT REQUIRED TO INSTALL NEW CONSTRUCTION. SEE ARCHITECTURAL NEW
WORK
D2 REMOVE PLUMBING FIXTURES AND TOILET ACCESSORIES.
D3 REMOVE FURRED WALL STRUCTURE SLAB TO DECK
D4 REMOVE EXISTING WINDOW, FRAME, SILL, SHADES, BLINDS, AND ALL ASSOCIATED HARDWARE. PREPARE FOR NEW
WINDOW INSTALLATION OR INFILL. SEE NEW WORK PLANS
D5 REMOVE DOOR(S) AND FRAME(S). (TO INCLUDE STOPS & HOLD OPENS WHERE THEY OCCUR)
D6 REMOVE EXTERIOR MASONRY WALL (BRICK & CMU), INCLUDING ALL WINDOWS, DOORS, ETC. IN AREA INDICATED. EXIST.
FOUNDATION & FOOTING TO REMAIN IN PLACE FOR REUSE W/ NEW EXTERIOR CLOSURE SYSTEM - SEE STRUCT. DWGS.
D7 REMOVE PORTION OF WALL INDICATED. INSTALL LINTEL PER STRUCTURAL AS REQUIRED. SEE ARCHITECTURAL PLANS
FOR SIZE.
D8 REMOVE LANDING, STAIR, AND FOUNDATION
D9 REFER TO MECHANICAL DEMO PLAN
D10 REMOVE EXISTING MILLWORK AND ALL ASSOICATED COMPONENTS.
D11 CAREFULLY REMOVE EXISTING PARTITION AS NEEDED FOR NEW DOOR INSTALLATION. PROVIDE TEMPORARY SUPPORT
AT OPENING DURING CONSTRUCTION. REFER TO NEW WORK PLAN FOR NEW DOOR LOCATION
D12 CAREFULLY REMOVE EXISTING CONCRETE SLAB TO THE EXTENT SHOWN TO PREPARE FOR NEW WORK REFER TO NEW
WORK PLAN FOR DIMENSIONS
D13 REMOVE EXISTING STONE BELT TO EXTENT REQUIRED TO INSTALL NEW CONSTRUCTION. SEE ARCHITECTURAL NEW
WORK
D14 REMOVE ALL ROOM FINISHES. REMOVE FLOOR FINISHES DOWN TO SLAB. PREPARE EXISTING SLAB TO RECEIVE NEW
FLOORING.
D15 REMOVE ELEVATOR AND ALL ASSOCIATED EQUIPMENT DOWN TO PIT
D16 REMOVE ALL CEILINGS AND BULKHEADS INCLUDING ALL ANCHORS, HANGERS, LIGHTING DEVICES, ETC.
D17 REMOVE LOCKERS
D18 REMOVE CORRIDOR WALL FINISHES, CORNER GUARDS, WALL PROTECTION FLOORING DOWN TO SLAB, BASE, AND ALL
OTHER FINISH ITEMS.
SCALE: 1/8" = 1'-0"
ATTIC FLOOR DEMO PLAN BID DEDUCT 1
SCALE: 1/8" = 1'-0"
ROOF LEVEL DEMO PLAN BID DEDUCT 1
KEYNOTES - ROOF PLAN
# DESCRIPTION
R1 ROOF DRAIN AND OVERFLOW DRAIN. SEE DETAIL 2/AE550.
R2 PARAPET WALL TO WRAP ROUND EXTENDED COLUMNS WHICH ARE 4 FT ABOVE FINISHED FLOOR TO ALLOW FOR
CONNECTION OF FUTURE FLOOR. (REFER TO STRUCTURAL DRAWINGS)
R3 FALL PROTECTION ANCHOR: CONTRACTOR SHALL PERFORM A DELEGATED DESIGN TO MEET ALL STRUCTURAL AND
OSHA REQUIREMENTS AND THE DESIGN SHALL BE STAMPED BY THE CONTRACTOR ENGINEERS
2/15/2023 85 of 233
T P
R
S P
S P
AT
AT
AT AT
AT
AT
ATAT
AT
DA
AT AT
AT AT
W P
S -3
WPS-3
W P
S -3
P T
-6
PT-6
PT-6 & IMAGE
VWC-3 ON
WALL
P T
-6
WPS-3
W P
S -3
W P
S -3
WPS-3
W P
S -3
WPS-3
W P
S -3
WPS-3
WPS-3
T P
R
DOOR STAIR
2' - 8"
5' - 0"
E
94 94
N1
N1
N1
N1
N1
S P
S P
F
TV
CR
D A
DA
DA
N L
N L
N L
N L
NL
NS
J J
VS
WF
T V
T V
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
5.2
A.A
A.9
AE-551
ADMIN
CONFERENCE
30418
BUILDING
ELECTRICAL
30416
ELEVATOR
LOBBY
3C05
GROUP ROOM
C
30436
LOUNGE
30443
CORRIDOR
3C07
GENDER
NEUTRAL
TOILET
30447
GENDER
NEUTRAL
TOILET
30449
BUILDING
DATA
30451
STAFF BREAK
30453
GENDER
NEUTRAL
TOILET
30452
FAMILY
TOILET
30448
HVAC
30446 OFFICE
30459
EAST STAIR
3S1
AE-511
AE-516
STORAGE
30450
C1
C2
C1
C1
GROUP ROOM
C
30436
CORRIDOR
3C07
ELEVATOR
LOBBY
3C05
BUILDING
ELECTRICAL
30416
BUILDING
DATA
30451
STAFF BREAK
30453
GENDER
NEUTRAL
TOILET
30449
FAMILY
TOILET
30448
GENDER
NEUTRAL
TOILET
30447
GENDER
NEUTRAL
TOILET
30452
HVAC
30446 OFFICE
30459
LOUNGE
30443
ADMIN
CONFERENCE
30418
EAST STAIR
3S1
CORRIDOR
3C03
CORRIDOR
3C04
CORRIDOR
3C08
STORAGE
30450
F1
FLOOR DIRECTORY -
SIGN TYPE 'D' REFER
TO SHEET AE305
GENERAL NOTE APPLICABLE TO ALL DRAWINGS - ITEMS AND CONDITIONS DETAILED NOTED OR OTHERWISE IDENTIFIED ON ONE OF THE SECTIONS OR DETAILS ARE APPLICABLE AND BINDING TO ALL OTHER SECTIONS AND DETAILS FOR IDENTICAL OR
SIMILAR CONDITIONS.
1. TYPICAL CEILING HEIGHT TO BE UNLESS OTHERWISE INDICATED ON REFLECTED CEILING PLANS. BULKHEADS TO BE 8'-0" UNLESS OTHERWISE INDICATED ON REFLECTED CEILING PLANS OR DETAILS. TOILETS AND STORAGE ROOMS TO BE
8'-0".
2. REFER TO ELECTRICAL DRAWINGS FOR LIGHT PATTERN AND EXIT LIGHT LOCATIONS. NOTIFY ARCHITECT OF
DISCREPANCIES PRIOR TO SHOP DRAWINGS.
3. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ITEMS NOT SHOWN ON CEILING PLAN. GRILLES, SPEAKERS, SPRINKLERS, HEAT & SMOKE DETECTORS, TO BE CENTERED IN TILES UNLESS NOTED OTHERWISE.
4. ALL BULKHEAD DIMENSIONS ARE FROM FINISH FACE OF WALL OR BULKHEAD TO FINISH FACE OF BULKHEAD.
5. PROVIDE 1/2" REVEALS BETWEEN DISSIMILAR MATERIALS ON THE SAME PLANE AT THE CEILINGS.
6. CEILING HEIGHTS ARE DIMENSIONED FROM FLOOR DATUM ELEVATION TO FINISHED CEILING, UNLESS OTHERWISE NOTED.
7. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION RELATIVE TO DEVICE AND FIXTURE
LOCATIONS.
8. COORDINATE INTEGRATION OF CEILING SYSTEMS WORK INCLUDING, BUT NOT LIMITED TO, MECHANICAL, ELECTRICAL, SPRINKLER AND FIRE PROTECTION, TELECOMMUNICATIONS, AND STRUCTURAL SYSTEMS, TO MAINTAIN CEILING HEIGHT
INDICATED. NOTIFY ARCHITECT OF CONFLICTS PRIOR TO PROCEEDING WITH THE WORK.
9. LOCATE COMPONENTS WITHIN CEILING PLENUM TO MAXIMIZE CLEAR AREA FOR INSTALLATION OF LIGHT FIXTURES AND
ACCOMMODATE FIXTURE LAYOUT AS INDICATED..
10. PROVIDE ACCESS PANELS AT GYPSUM BOARD CEILINGS AND WHERE ACCESS IS REQUIRED FOR ITEMS OF MECHANICAL, PLUMBING AND ELECTRICAL WORK LOCATED BEHIND OR ABOVE FINISHED WALLS OR CEILINGS WHICH REQUIRE ACCESS, WHETHER OR NOT SUCH PANELS ARE INDICATED ON DRAWINGS. VERIFY LOCATION OF ACCESS PANELS WITH ARCHITECT
PRIOR TO INSTALLATION.
11. REVIEW LOCATION OF LIFE-SAFETY DEVICES AND/OR EQUIPMENT NOT SHOWN ON THE DRAWINGS WITH ARCHITECT
PRIOR TO INSTALLATION.
12. COORDINATE ABOVE CEILING DRAFTSTOP LOCATIONS IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND
AUTHORITIES HAVING JURISDICTION.
13. ACOUSTICAL CEILING GRID AND LIGHTING SHALL BE CENTERED IN ROOM(S) UNLESS NOTED OTHERWISE.
14. CENTER RECESSED LIGHTS, ELECTRICAL, MECHANICAL DEVICES AND SPRINKLER HEADS WHEN SHOWN IN CEILING TILES.
WHERE RECESSED LIGHTS ARE SHOWN OFF-CENTER IN 2X4 SCORED CEILING TILE, CENTER THE FIXTURE WITHIN THE 2X2
PORTION OF THE TILE.
15. CEILING FINISHES ADJACENT TO OR WITHIN THE LIMITS OF CONSTRUCTION DISTURBED OR DAMAGED BY CONSTRUCTION
SHALL BE PATCHED TO MATCH EXISTING ADJACENT CEILING FINISH.
16. SEE SHEETS FA001, FP001, MH001 AND EJ001 FOR CEILING EQUIPMENT LEGENDS.
17. AT WINDOW HEAD, CEILING IS 8'-10 1/2" TO ACCOMMODATE FOR HEAD OF WINDOW. SEE DETAIL 1/AE516.
GENERAL NOTES - RCP
8'-0"
TT-1: TERRAZZO TILE -
COLOR 1
HR-# & WP-# (HAND RAILS & RIGID SHEET \
WALL PROTECTION)
CG-# (CORNER GUARD \ WALL PROTECTION)
CPT-1: CARPET
TILE - COLOR 1
CPT-2: CARPET
TILE - COLOR 2
CPT-3: CARPET
TILE - COLOR 3
PFT-1: PORCELAIN FLOOR
TILE - COLOR 1
PFT-2: PORCELAIN FLOOR
TILE - COLOR 2
PFT-3: PORCELAIN FLOOR
TILE - COLOR 3
RFT-1: RESILIENT FLOOR
TILE - COLOR 1
CONC-1
LVT-1: LUXURY
VINYL TILE - COLOR 1
LVT-2: LUXURY
VINYL TILE - COLOR 2
RSF-1: RESILIENT SHEET
FLOORING - COLOR 1
RSF-2: RESILIENT SHEET
FLOORING - COLOR 2
TT-2: TERRAZZO TILE -
COLOR 2
LVT-3: LUXURY
VINYL TILE - COLOR 3
LVT-4: LUXURY
VINYL TILE - COLOR 4
LVT-5: LUXURY
VINYL TILE - COLOR 5
ACT-1: ACOUSTIC PANEL CLG. - 2'X2'
ACT-2: ACOUSTIC PANEL CLG. - 2'X2' CLEAN ROOM
EXP: EXPOSED CONSTRUCTION - PAINTED
PT#: PAINT - COLOR #
ETR: EXISTING TO REMAIN
N.I.C: NOT IN CONTRACT
CEILINGS
BASES
NONE: NO BASE
CTB-1: CERAMIC TILE BASE - COLOR 1
CTB-2: CERAMIC TILE BASE - COLOR 2
RSFB-1: RESILIENT SHEET BASE - COLOR 1
RSFB-2: RESILIENT SHEET BASE - COLOR 2
RB-1: RESILIENT SHEET BASE, INTEGRAL
- COLOR 1
RB-2: RESILIENT SHEET BASE, INTEGRAL
- COLOR 2
TT-1: TERRAZZO TILE BASE - COLOR 1
TT-2: TERRAZZO TILE BASE - COLOR 2
MTB-1: WALK OFF MAT BASE - COLOR 1
ETR: EXISTING TO REMAIN
N.I.C: NOT IN CONTRACT
WALLS
CT1: CERAMIC TILE - COLOR 1
CT2: CERAMIC TILE - COLOR 2
PT#: PAINT - COLOR #
WPS-1: WALL PROTECTION SYSTEM (HANDRAIL) - COLOR 1
WPS-2: WALL PROTECTION SYSTEM (HANDRAIL) - COLOR 2
WPS-3: WALL PROTECTION SYSTEM (HANDRAIL) - COLOR 3
PL-0: PLASTIC LAMINATE - COLOR 0
PL-1: PLASTIC LAMINATE - COLOR 1
VWC#: FULL WALL GRAPHIC IMAGE #
DFP-1: DIVIDE PARTITION PANEL - 1
OP-1: OPERABLE PARTITION
CWC: CORK WALL FINISH - ACOUSTICS WALL COVERING
ETR: EXISTING TO REMAIN
N.I.C: NOT IN CONTRACT
FLOORS:
ETR : EXISTING TO REMAIN
FINISH MATERIALS
WT-# (ROLLER SHADE \ WINDOW
TREATMENT)
PT-#, CT-#, ETC. (WALL FINISH EXTENTS)
SPACES NOT LISTED ON THE SCHEDULE TO HAVE THE TYPICAL
FINISHES LISTED BELOW:
FLOORS: REFER TO FINISH PLAN AND SCHEDULE
BASE: REFER TO FINISH PLAN & SCHEDULE
WALLS: PT-1
CEILING: ACT-1
GYP. BD. ABOVE H.M. FRAMES AS INDICATED ON SECTIONS.
DETAILS TO RECEIVE SAME TOP COATS AS ADJACENT WALLS
UNLESS OTHERWISE NOTED.
TYPICAL FINISHES
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
5.2
A.A
A.9
AE-551
1/4" PER 1'-0" TAPERED INSULATION
AND EPDM ROOFING
ROOF PARAPET
AND EXPANSION
JOINT
PARAPET CAP EXPANSION JOINT
EXPANSION JOINT
CRICKET LOCATIONS TO BE
CONFIRMED ON SITE
ACCORDING TO EXISTING
ROOF SLOPE
SLOPE 1/4"
PER FOOTSLOPE 1/4"
PER FOOT
S
LO
P E
/4
P
E R
F O
O T
S
LO
P E
/4
P
E R
F O
O T
3'-0" 18'-7 1/8" 3'-0"
+3 +3
+2
+3
+3 +3
+2 +2
SLOPE 1/4"
PER FOOT
S
LO
P E
/4
P
E R
F O
O T
S
LO
P E
/4
P
E R
F O
O T
SLOPE 1/4"
PER FOOT
SLOPE 1/4"
PER FOOT +3
+3
+3
AE-506
AE-506
AE-506
AE-506
METAL DECK SCREEN WALL ASSEMBLY.
SEE STRUCT.
AE-417
AE-417
R1
R1
R1
BD-104
R2R2
R2
R2
R3 R3
1. UNIFORMLY SLOPE TAPERED INSULATION MINIMUM 1/4" IN HEIGHT PER 1'-0" HORIZONTALLY (OR AS REQUIRED BY
CODE) AT LEVEL ROOF AREAS, UNLESS OTHERWISE NOTED.
2. MINIMUM ROOF INSULATION THICKNESS AT ROOF DRAINS (LOW POINT) MUST MAINTAIN THE R-VALUE THAT IS REQUIRED BASED ON ASHRAE 90.1. SLOPE CRICKET INSULATION TO DRAIN AROUND PENETRATIONS (VENTS, STACK, ETC) AND AT VALLEYS BETWEEN ROOF DRAINS SHALL TAPER UPWARDS TO MAINTAIN THE SLOPE.
3. UNLESS THERE ARE SCUPPERS PROVIDE SECONDARY ROOF DRAINS 2" ABOVE PRIMARY ROOF DRAIN.
4. SEE AE550 AND AE551 FOR ROOF DETAILS.
GENERAL NOTES - ROOF PLAN
A
B
C
D
C.3
95 876 10 117.66.4
A.8
B.9
5.2
A.A
A.9
GROUP ROOM
C
30436
ELEVATOR
LOBBY
3C05
BUILDING
ELECTRICAL
30416
BUILDING
DATA
30451
STAFF BREAK
30453
GENDER
NEUTRAL
TOILET
30449
FAMILY
TOILET
30448
GENDER
NEUTRAL
TOILET
30447
GENDER
NEUTRAL
TOILET
30452
HVAC
30446
OFFICE
30459
LOUNGE
30443
ADMIN
CONFERENCE
30418
EAST STAIR
3S1
CORRIDOR
3C04
CORRIDOR
3C08
F1
STORAGE
30450
SIGN TYPE D
T V
(N .I
.C
TV(N.I.C)
T V
(N .I
.C
STORAGE
30436A
N
KEY PLAN(BID DEDUCT 1)
NEW ADDITION
A R C H I T E C T S E N G I N E E R S
CB
Drawing Number:
Project Title:
Project Location:
Issue Date
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Subm…