Attachment 10 - Drawing Part 7 676-325 Renovate B404 - Fire Supression.pdf

PDF 4 MB Posted

Attached to
Y1DA--Minor Construction - Tomah VAMC 676-325 Expand and Renovate B404 for Outpatient Mental Health
Solicitation number
36C77623B0050_1
Issued by

About this file

This document package includes construction drawings and specifications for an expansion and renovation project at the Tomah VA Medical Center in Tomah, Wisconsin. The project involves renovating space in Building 404 for outpatient mental health services, including adding new areas on the second and third floors. Fire protection, including sprinkler and alarm systems, will be upgraded throughout in accordance with NFPA standards. Bids are due by January 2023 for award in February, with work to be completed by December 2023. The total budget for the project is $5 million.

View the file

Other files

File Type Posted
Amendment 0007 Attachment 33 - Wage Determination 02-02-24.pdf PDF
Amendment_0007 36C77623B0050_1 0007.pdf PDF
Amendment_0006 36C77623B0050_1 pdf.pdf PDF
Amendment_0005 Attachment 31 - VAT-MP-ADD-1 - Response to 39.pdf PDF
Amendment_0005 Attachment 25 - B404 ACM Spreadsheet Inventory 2015 - Response to 1.pdf PDF
Amendment_0005 Attachment 29 - Response to 34.pdf PDF
Amendment_0005 Attachment 32 - Replace HVAC AC B404 Record Drawings Set - Response to 38.pdf PDF
Amendment_0005 36C77623B0050_1 pdf.pdf PDF
Amendment_0005 Attachment 30 -237413 PackagedOutdoorCentral-Station Air-Handling Units_addendum 1.pdf PDF
Amendment_0005 Attachment 24 - 2431 Tomah WI ACM - Response to 1.pdf PDF
Amendment_0005 Attachment 26 - Spec Section 27 52 23 - Response to 15.pdf PDF
Amendment_0005 Attachment 27 - Spec Section 26 29 11 - Response to 16.pdf PDF
Amendment_0005 Attachment 28 - B404 TR - Response to 18.pdf PDF
Amendment_0005 Attachment 23 - Tomah Technical Questions and VA Responses.pdf PDF
Amendment_0004 36C77623B0050_1 .pdf PDF
Amendment _0003 36C77623B0050_1 .pdf PDF
Amendment_0002 Attachment 21 - Tomah Site Visit sign-in sheet.pdf PDF
Amendment_0002 36C77623B0050_1 .pdf PDF
Attachment 2 - Bid Set - Spec V1R.pdf PDF
Amendment_0001 36C77623B0050_1 pdf.pdf PDF
Amendment_0001 Attachment 20 - 676-325 Renovate B404 - Structural Pages SG-001 to SB-100.pdf PDF
Amendment_0001 Attachment 3 - Bid Set - Spec V2R revised.pdf PDF
Attachment 17 - VA Notice of Limitations on Subcontracting.pdf PDF
Attachment 15 - Drawing Part 12 676-325 Renovate B404 - Structural.pdf PDF
36C77623B0050_1.pdf PDF
Attachment 6 - Drawing Part 3 676-325 Renovate B404 - Architectural_Part2.pdf PDF
Attachment 7 - Drawing Part 4 676-325 Renovate B404 - Architectural_Part3.pdf PDF
Attachment 18 - Wage Determination 10-13-23.pdf PDF
Attachment 5 - Drawing Part 2 676-325 Renovate B404 - Architectural_Part1.pdf PDF
Attachment 4 - Drawing Part 1 676-325 Renovate B404 - Architectural.pdf PDF
Attachment 13 - Drawing Part 10 676-325 Renovate B404 - Plumbing.pdf PDF
Attachment 1 - Statement of Work - Tomah.pdf PDF
Attachment 19 - Brand Name JA Tomah.pdf PDF
Attachment 3 - Bid Set - Spec V2R.pdf PDF
Attachment 2 - Bid Set - Spec V1R.pdf PDF
Attachment 8 - Drawing Part 5 676-325 Renovate B404 - Electrical and Technology.pdf PDF
Attachment 16 - GeoTech Report.pdf PDF
Attachment 11 - Drawing Part 8 676-325 Renovate B404 - Floor Plans.pdf PDF
Attachment 12 - Drawing Part 9 676-325 Renovate B404 - Mechanical.pdf PDF
Attachment 9 - Drawing Part 6 676-325 Renovate B404 - Finishes.pdf PDF
Attachment 14 - Drawing Part 11 676-325 Renovate B404 - Site Drawings GI-001 to LS-101.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WF

VSVSVS

VS

WF

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

FX02

C

D

E

F

H

E.8

C.3

G

FX01

FX01

FD02

FD01

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL SPRINKLERS, SPRINKLER PIPE, HANGERS, CONTROL VALVE

ASSEMBLIES AND ASSOCIATED APPURTENANCES ON EACH FLOOR WITH THE

EXCEPTION OF THE FOLLOWING:

a. EXISTING INCOMING WATER SHALL REMAIN

b. EXISTING BULK PIPE TO STANDPIPES SHALL REMAIN

c. EXISTING STANDPIPES SHALL REMAIN

d. EXISTING 2½" HOSE CONNECTIONS SHALL REMAIN

e. ALL FIRE SUPPRESSION SYSTEMS IN ATTIC TO REMAIN.

B. THE EXISTING CHECK VALVE AND CONTROL VALVE AT THE INCOMING WATER

LOCATION SHALL BE DEMOLISHED AND REPLACED WITH A NEW DOUBLE

CHECK BACK FLOW PREVENTER.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE SPRINKLER DEMOLITION WITH OVERALL CONSTRUCTION

PHASING TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE

FIRE SPRINKLER PROTECTION.

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

5. CAP PIPE AT LIMITS OF CONSTRUCTION WHEN APPLICABLE

FIRE SUPPRESSION DEMO NOTES

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL FIRE ALARM DEVICES, PANELS, CONDUIT, HANGERS, AND

ASSOCIATED APPURTENANCES.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE ALARM DEMOLITION WITH OVERALL CONSTRUCTION PHASING

TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE AN FIRE

ALARM SYSTEM

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

FIRE ALARM DEMO NOTES

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE PROTECTION DEMOLITION

PLAN - BASEMENT

FD-100

-3

F D

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE PROTECTION DEMO PLAN - BASEMENT

N

KEYNOTE LEGEND

KEY DESCRIPTION

FD01 HATCH INDICATES TO DEMOLISH ALL INTERIOR SPRINKLER PIPING,

SPRINKLERS, AND ASSOCIATED HANGERS UNLESS NOTED OTHERWISE.

FD02 HATCH INDICATES TO DEMOLISH ALL INTERIOR FIRE ALARM SYSTEM DEVICES,

INCLUDING BUT NOT LIMITED TO THE FIRE ALARM PANEL, THE REMOTE

ANNUNCIATOR PANEL, NOTIFICATION DEVICES, SIGNALING DEVICES, AND

INITIATING DEVICES.

FX01 EXISTING STANDPIPES AND BULK FEED PIPING TO STANDPIPES SHALL REMAIN.

EXISTING 2-1/2" HOSE CONNECTIONS SHALL REMAIN

FX02 DEMOLISH EXISTING CHECK VALVE AND CONTROL VALVE AT INCOMING WATER

LOCATION. INSTALL NEW DOUBLE CHECK BACKFLOW PREVENTER WITH

SUPERVISED CONTROL VALVES.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

CB DESIGN

GROUP

128 241124 of 233124 of 233

WF WF

F A

C P

VS VS

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

FD04 FD04

FD01

FD04

FD03

C

D

E

F

H

E.8

C.3

G

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL SPRINKLERS, SPRINKLER PIPE, HANGERS, CONTROL VALVE

ASSEMBLIES AND ASSOCIATED APPURTENANCES ON EACH FLOOR WITH THE

EXCEPTION OF THE FOLLOWING:

a. EXISTING INCOMING WATER SHALL REMAIN

b. EXISTING BULK PIPE TO STANDPIPES SHALL REMAIN

c. EXISTING STANDPIPES SHALL REMAIN

d. EXISTING 2½" HOSE CONNECTIONS SHALL REMAIN

e. ALL FIRE SUPPRESSION SYSTEMS IN ATTIC TO REMAIN.

B. THE EXISTING CHECK VALVE AND CONTROL VALVE AT THE INCOMING WATER

LOCATION SHALL BE DEMOLISHED AND REPLACED WITH A NEW DOUBLE

CHECK BACK FLOW PREVENTER.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE SPRINKLER DEMOLITION WITH OVERALL CONSTRUCTION

PHASING TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE

FIRE SPRINKLER PROTECTION.

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

5. CAP PIPE AT LIMITS OF CONSTRUCTION WHEN APPLICABLE

FIRE SUPPRESSION DEMO NOTES

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL FIRE ALARM DEVICES, PANELS, CONDUIT, HANGERS, AND

ASSOCIATED APPURTENANCES.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE ALARM DEMOLITION WITH OVERALL CONSTRUCTION PHASING

TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE AN FIRE

ALARM SYSTEM

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

FIRE ALARM DEMO NOTES

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE PROTECTION DEMOLITION

PLAN - FIRST FLOOR

FD-101

-3

F D

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE PROTECTION DEMO PLAN - FIRST FLOOR

N

KEYNOTE LEGEND

KEY DESCRIPTION

FD01 HATCH INDICATES TO DEMOLISH ALL INTERIOR SPRINKLER PIPING,

SPRINKLERS, AND ASSOCIATED HANGERS UNLESS NOTED OTHERWISE.

FD03 REMOVE AND SALVAGE EXISTING FIRE ALARM PANEL. PANEL TO BE

RELOCATED AND REUSED. EXISTING PANEL IS A FARENHYT IFP-2100/ECS.

FD04 EXISTING STANDPIPES AND BULK FEEDS TO STANDPIPES ARE TO REMAIN.

EXISTING 2-1/2" HOSE CONNECTIONS SHALL REMAIN. DEMOLISH SPRINKLER

PIPING BACK TO STANDPIPE CONNECTION INCLUDING DEMOLISHING EXISTING

RISER ASSEMBLIES.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

129 241125 of 233125 of 233

WF WF

VS VS

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

FD04 FD04

FD01

FD02

C

D

E

F

H

E.8

C.3

G

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL SPRINKLERS, SPRINKLER PIPE, HANGERS, CONTROL VALVE

ASSEMBLIES AND ASSOCIATED APPURTENANCES ON EACH FLOOR WITH THE

EXCEPTION OF THE FOLLOWING:

a. EXISTING INCOMING WATER SHALL REMAIN

b. EXISTING BULK PIPE TO STANDPIPES SHALL REMAIN

c. EXISTING STANDPIPES SHALL REMAIN

d. EXISTING 2½" HOSE CONNECTIONS SHALL REMAIN

e. ALL FIRE SUPPRESSION SYSTEMS IN ATTIC TO REMAIN.

B. THE EXISTING CHECK VALVE AND CONTROL VALVE AT THE INCOMING WATER

LOCATION SHALL BE DEMOLISHED AND REPLACED WITH A NEW DOUBLE

CHECK BACK FLOW PREVENTER.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE SPRINKLER DEMOLITION WITH OVERALL CONSTRUCTION

PHASING TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE

FIRE SPRINKLER PROTECTION.

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

5. CAP PIPE AT LIMITS OF CONSTRUCTION WHEN APPLICABLE

FIRE SUPPRESSION DEMO NOTES

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL FIRE ALARM DEVICES, PANELS, CONDUIT, HANGERS, AND

ASSOCIATED APPURTENANCES.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE ALARM DEMOLITION WITH OVERALL CONSTRUCTION PHASING

TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE AN FIRE

ALARM SYSTEM

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

FIRE ALARM DEMO NOTES

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE PROTECTION DEMOLITION

PLAN - SECOND FLOOR

FD-102

-3

F D

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE PROTECTION DEMO PLAN - SECOND FLOOR

N

KEYNOTE LEGEND

KEY DESCRIPTION

FD01 HATCH INDICATES TO DEMOLISH ALL INTERIOR SPRINKLER PIPING,

SPRINKLERS, AND ASSOCIATED HANGERS UNLESS NOTED OTHERWISE.

FD02 HATCH INDICATES TO DEMOLISH ALL INTERIOR FIRE ALARM SYSTEM DEVICES,

INCLUDING BUT NOT LIMITED TO THE FIRE ALARM PANEL, THE REMOTE

ANNUNCIATOR PANEL, NOTIFICATION DEVICES, SIGNALING DEVICES, AND

INITIATING DEVICES.

FD04 EXISTING STANDPIPES AND BULK FEEDS TO STANDPIPES ARE TO REMAIN.

EXISTING 2-1/2" HOSE CONNECTIONS SHALL REMAIN. DEMOLISH SPRINKLER

PIPING BACK TO STANDPIPE CONNECTION INCLUDING DEMOLISHING EXISTING

RISER ASSEMBLIES.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

130 241126 of 233126 of 233

WF

WFVS

VS

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

FD04 FD04

FD01

C

D

E

F

H

E.8

C.3

G

FD02

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL SPRINKLERS, SPRINKLER PIPE, HANGERS, CONTROL VALVE

ASSEMBLIES AND ASSOCIATED APPURTENANCES ON EACH FLOOR WITH THE

EXCEPTION OF THE FOLLOWING:

a. EXISTING INCOMING WATER SHALL REMAIN

b. EXISTING BULK PIPE TO STANDPIPES SHALL REMAIN

c. EXISTING STANDPIPES SHALL REMAIN

d. EXISTING 2½" HOSE CONNECTIONS SHALL REMAIN

e. ALL FIRE SUPPRESSION SYSTEMS IN ATTIC TO REMAIN.

B. THE EXISTING CHECK VALVE AND CONTROL VALVE AT THE INCOMING WATER

LOCATION SHALL BE DEMOLISHED AND REPLACED WITH A NEW DOUBLE

CHECK BACK FLOW PREVENTER.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE SPRINKLER DEMOLITION WITH OVERALL CONSTRUCTION

PHASING TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE

FIRE SPRINKLER PROTECTION.

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

5. CAP PIPE AT LIMITS OF CONSTRUCTION WHEN APPLICABLE

FIRE SUPPRESSION DEMO NOTES

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL FIRE ALARM DEVICES, PANELS, CONDUIT, HANGERS, AND

ASSOCIATED APPURTENANCES.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE ALARM DEMOLITION WITH OVERALL CONSTRUCTION PHASING

TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE AN FIRE

ALARM SYSTEM

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

FIRE ALARM DEMO NOTES

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE PROTECTION DEMOLITION

PLAN - THIRD FLOOR

FD-103

-3

F D

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE PROTECTION DEMO PLAN - THIRD FLOOR

N

KEYNOTE LEGEND

KEY DESCRIPTION

FD01 HATCH INDICATES TO DEMOLISH ALL INTERIOR SPRINKLER PIPING,

SPRINKLERS, AND ASSOCIATED HANGERS UNLESS NOTED OTHERWISE.

FD02 HATCH INDICATES TO DEMOLISH ALL INTERIOR FIRE ALARM SYSTEM DEVICES,

INCLUDING BUT NOT LIMITED TO THE FIRE ALARM PANEL, THE REMOTE

ANNUNCIATOR PANEL, NOTIFICATION DEVICES, SIGNALING DEVICES, AND

INITIATING DEVICES.

FD04 EXISTING STANDPIPES AND BULK FEEDS TO STANDPIPES ARE TO REMAIN.

EXISTING 2-1/2" HOSE CONNECTIONS SHALL REMAIN. DEMOLISH SPRINKLER

PIPING BACK TO STANDPIPE CONNECTION INCLUDING DEMOLISHING EXISTING

RISER ASSEMBLIES.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

131 241127 of 233127 of 233

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

FD02

C

D

E

F

H

E.8

C.3

G

FX08

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL SPRINKLERS, SPRINKLER PIPE, HANGERS, CONTROL VALVE

ASSEMBLIES AND ASSOCIATED APPURTENANCES ON EACH FLOOR WITH THE

EXCEPTION OF THE FOLLOWING:

a. EXISTING INCOMING WATER SHALL REMAIN

b. EXISTING BULK PIPE TO STANDPIPES SHALL REMAIN

c. EXISTING STANDPIPES SHALL REMAIN

d. EXISTING 2½" HOSE CONNECTIONS SHALL REMAIN

e. ALL FIRE SUPPRESSION SYSTEMS IN ATTIC TO REMAIN.

B. THE EXISTING CHECK VALVE AND CONTROL VALVE AT THE INCOMING WATER

LOCATION SHALL BE DEMOLISHED AND REPLACED WITH A NEW DOUBLE

CHECK BACK FLOW PREVENTER.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE SPRINKLER DEMOLITION WITH OVERALL CONSTRUCTION

PHASING TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE

FIRE SPRINKLER PROTECTION.

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

5. CAP PIPE AT LIMITS OF CONSTRUCTION WHEN APPLICABLE

FIRE SUPPRESSION DEMO NOTES

1. THE SCOPE OF DEMOLITION SHALL BE AS FOLLOWS

A. DEMO ALL FIRE ALARM DEVICES, PANELS, CONDUIT, HANGERS, AND

ASSOCIATED APPURTENANCES.

2. FOR GENERAL PHASING INFORMATION SEE ARCHITECTURAL DRAWINGS.

3. COORDINATE FIRE ALARM DEMOLITION WITH OVERALL CONSTRUCTION PHASING

TO ENSURE NO OCCUPIED AREA OF THE BUILDING IS WITHOUT ACTIVE AN FIRE

ALARM SYSTEM

4. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE

DEMOLITION SCOPE AND NOT ALL ITEMS ARE NECESSARILY SHOWN. THE

CONTRACTOR SHALL FIELD VERIFY SCOPE PRIOR TO STARTING WORK.

FIRE ALARM DEMO NOTES

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE PROTECTION DEMOLITION

PLAN - ATTIC

FD-104

-3

F D

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE PROTECTION DEMO PLAN - ATTIC

N

KEYNOTE LEGEND

KEY DESCRIPTION

FD02 HATCH INDICATES TO DEMOLISH ALL INTERIOR FIRE ALARM SYSTEM DEVICES,

INCLUDING BUT NOT LIMITED TO THE FIRE ALARM PANEL, THE REMOTE

ANNUNCIATOR PANEL, NOTIFICATION DEVICES, SIGNALING DEVICES, AND

INITIATING DEVICES.

FX08 ALL FIRE SUPPRESSION SYSTEMS IN HATCHED PORTION OF ATTIC TO REMAIN.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

132 241128 of 233128 of 233

DH

DCL

F

F

S

CO

S

ID

S P

WF

VS

FAA

FACP

FATC

TPR

NAC

H R

CO

F S P

F S P

F S P

VSWF

VSWF

VSWF

VSWF

S

ID

VSWF

S P

H R

AIM

RL

H R

1. PROVIDE AND INSTALL A NEW FIRE ALARM SYSTEM THROUGHOUT THE BUILDING

PER THE VA FIRE PROTECTION DESIGN MANUAL AND NFPA 72.

2. THE NEW FIRE ALARM SYSTEM SHALL BE A VOICE EVACUATION TYPE SYSTEM.

WITH A MICROPHONE LOCATED AT THE FIRE ALARM PANEL FOR EMERGENCY

NOTIFICATION.

3. THE EXISTING FIRE ALARM PANEL SHALL BE REMOVED AND RELOCATED TO THE

ELECTRICAL ROOM AS INDICATED ON THE DRAWINGS. NEW NOTIFICATION AND

INITIATING DEVICES SHALL BE PROVIDED AND COMPATIBLE WITH THE EXISTING

PANEL.

4. THE FIRE ALARM SYSTEM SHALL BE ZONED PER FLOOR.

5. THE EXISTING CAMPUS FIRE ALARM PANEL IS A FARENHYT IFP-2100/ECS PANEL.

NEW FIRE ALARM SYSTEM COMPONENTS MUST BE COMPATIBLE WITH THIS.

6. THE FIRE ALARM SYSTEM SHALL REPORT TO THE CONSTANTLY ATTENDED

STATION AT THE VA TOMAH FIRE DEPARTMENT.

7. THE CONTRACTOR SHALL PROVIDE INSTALLATION SHOP DRAWINGS FOR REVIEW

BY OWNER AND A/E PRIOR TO INSTALLATION.

8. EXISTING FIRE ALARM DEVICES SHALL BE RETAINED AND SALVAGED FOR VA USE.

COORDINATE WITH VA COR.

9. PROVIDE FIRE SEAL FOR INSERTS, SLEEVES AND CONDUIT PENETRATIONS

THROUGH WALLS, CEILINGS AND FLOORS AS PER SPECIFICATIONS

10. COORDINATE FIRE ALARM SYSTEM DEVICE LOCATIONS WITH LIGHT FIXTURES,

STRUCTURAL MEMBERS, SPRINKLER HEADS AND PIPING, HVAC EQUIPMENT AND

DUCTWORK.

11. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL OPERATING SYSTEMS AS

INDICATED ON THE CONTRACT DOCUMENTS AND AS EVIDENTLY INTENDED. IT IS

NOTED THAT THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL

ARRANGEMENTS OF SYSTEMS AND WORK. THE CONTRACTOR SHALL FURNISH

AND INSTALL CONDUIT AND WIRING AS REQUIRED TO ACCOMPLISH THE

FUNCTIONS INDICATED. THE CONTRACTOR SHALL FURNISH AND INSTALL THE

REQUIRED QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS,

REMOTE POWER SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC.,

AS REQUIRED BY THE SYSTEM MANUFACTURER, THE SPECIFICATIONS, AND ANY

APPLICABLE CODES. ALL WIRING SHOWN ON RISER DIAGRAMS SHALL ALSO BE

FURNISHED AND INSTALLED REGARDLESS OF WHETHER THESE ITEMS ARE

SHOWN ON THE FLOOR PLANS.

12. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK

OF ALL OTHER TRADES AND EXISTING CONDITIONS SO AS TO AVOID CONFLICTS.

RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO ROUGH-IN. FAILURE TO

PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT BE

CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY

RESULT IN REJECTION OF THE WORK.

13. ADDITIONAL DEVICES MAY BE REQUIRED. CONTRACTOR TO VERIFY FINAL DEVICE

LAYOUT.

14. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION

INTENDED, AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY

TESTING LABORATORY LISTINGS ACCEPTABLE TO THE AUTHORITY HAVING

JURISDICTION.

15. VERIFY LOCATIONS OF WIRING DEVICES IN FINISHED SPACES, MILLWORK, AND

CASEWORK WITH ARCHITECTURAL DRAWINGS, DETAILS, AND ELEVATIONS, AND

WITH THE OWNER'S EQUIPMENT AND FURNITURE LAYOUTS PRIOR TO ROUGH-IN.

16. ALL FIRE ALARM CABLES SHOULD BE INSTALLED IN RED METAL RACEWAYS.

17. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES AND MAY

BE EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL

ROOMS. ALL RACEWAY AND WIRING SHALL BE ROUTED EITHER PERPENDICULAR

OR PARALLEL TO THE BUILDING'S STRUCTURAL COMPONENTS.

18. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND

INSTALLATION REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE

CONCEALED IN FINISHED SPACES AND LOCATIONS SHALL BE COORDINATED WITH

THE WORK OF ALL OTHER TRADES SO AS TO AVOID CONFLICTS.

19. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX,

CABINET, PULL BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL

AND CIRCUIT NUMBER, CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER

APPROPRIATE INFORMATION. ALL PULL AND JUNCTION BOXES SHALL BE LABELED

AS TO FUNCTION.

20. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS,

HANGERS, SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT

AND PREVENT EQUIPMENT MOVEMENT. ALL EQUIPMENT LOCATED IN SEISMIC

ZONES SHALL BE SECURED WITH MEANS APPROVED FOR THE SEISMIC

CLASSIFICATION ENCOUNTERED.

21. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED

WITH FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE

CONSTRUCTION TO BE PENETRATED. PROVIDE DOCUMENTATION ON ALL SUCH

PENETRATION SEALING SYSTEMS FOR VERIFICATION OF PROPER INSTALLATION.

22. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER

WATER OR MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH

APPROPRIATE SEALING FITTINGS OR SEALED CONSTRUCTION TO PREVENT THE

INTRODUCTION OF MOISTURE INTO THE BUILDING.

23. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH

ENDS AND FITTED WITH NYLON PULLSTRINGS FOR FUTURE USE.

24. ELECTRICAL WORK SHALL BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY TO

PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE. WHERE WORK

ON EXISTING SYSTEMS WILL REQUIRE INTERRUPTION OF ELECTRICAL SERVICE,

THEN TEMPORARY PROVISIONS ACCEPTABLE TO THE OWNER FOR TEMPORARY

POWER SHALL BE UTILIZED UNTIL THE WORK IS COMPLETE.

25. WALL MOUNTED FIRE ALARM PULL STATIONS ARE TO BE LOCATED 46" A.F.F. AND

WITHIN 5' OF THE NEAREST ADJACENT EXIT DOOR FROM THE FLOOR OR

BUILDING.

26. WALL MOUNTED FIRE ALARM NOTIFICATION APPLIANCES, EITHER VISUAL, OR

COMBINATION AUDIO/VISUAL, SHALL BE LOCATED SUCH THAT THE ENTIRE LENS

OF THE VISUAL PORTION IS BETWEEN 80" AND 96" A.F.F. AUDIO ONLY APPLIANCES

SHALL BE LOCATED, NOT LESS THAN 90" A.F.F. TO TOP OF APPLIANCE, OR 6"

BELOW CEILING.

FIRE ALARM/MNS GENERAL NOTESFIRE ALARM SYMBOLS

DEVICES

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

MANUAL PULL STATION

SPEAKER ONLY WALL MOUNTED

EXTERIOR BELL

STROBE ONLY CEILING MOUNTED

SYMBOL DESCRIPTION

DOOR HOLDER

DOOR CLOSER

DETECTORS

GAS DETECTOR - CARBON MONOXIDE

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

FLOW DETECTOR/SWITCH

VALVE SUPERVISORY SWITCH

SWITCHES

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM TRANSPONDER CABINET

NOTIFICATION CIRCUIT POWER BOOSTER

PANELS

STROBE ONLY WALL MOUNTED

HEAT DETECTOR - RATE OF RISE

FIRE ALARM

CONTROL PANEL

FRONT LOBBY -

RM 10440

INITIATING DEVICES

BASEMENT LEVEL FIRE/SMOKE

BASEMENT

NOTE: REPRESENTS NUMBER OF DEVICES

ON THIS LEVEL. CONTRACTOR SHALL

VERIFY ALL NECESSARY DEVICE COUNTS

LEVEL 1

LEVEL 2

LEVEL 3

ATTIC

= 1

NOTIFICATION DEVICES

SECOND LEVEL FIRE/SMOKE

INITIATING DEVICES SECOND LEVEL

FIRE/SMOKE

= 24

= 2

= 7

= 1

NOTIFICATION DEVICES

FIRST LEVEL FIRE/SMOKE

INITIATING DEVICES FIRST LEVEL

FIRE/SMOKE

= 22

= 8

= 14

= 2

NOTIFICATION DEVICES

THIRD LEVEL FIRE/SMOKE

INITIATING DEVICES THIRD LEVEL

FIRE/SMOKE

= 25

= 2

= 7

= 2

NOTIFICATION DEVICES

ATTIC LEVEL FIRE/SMOKE

INITIATING DEVICES ATTIC LEVEL

FIRE/SMOKE

= 4= 1

= 2= 2

= 2= 2

= 2= 2

NOTE: REPRESENTS NUMBER OF DEVICES

ON THIS LEVEL. CONTRACTOR SHALL

VERIFY ALL NECESSARY DEVICE COUNTS

NOTE: REPRESENTS NUMBER OF DEVICES

ON THIS LEVEL. CONTRACTOR SHALL

VERIFY ALL NECESSARY DEVICE COUNTS

NOTE: REPRESENTS NUMBER OF DEVICES

ON THIS LEVEL. CONTRACTOR SHALL

VERIFY ALL NECESSARY DEVICE COUNTS

NOTE: REPRESENTS NUMBER OF DEVICES

ON THIS LEVEL. CONTRACTOR SHALL

VERIFY ALL NECESSARY DEVICE COUNTS

FIRE ALARM

TRANSPONDER CABINET

BUILDING ELECTRICAL

ROOM 336

BASEMENT

LEVEL 1

LEVEL 2

LEVEL 3

ATTIC

NOTIFICATION DEVICES

BASEMENT LEVEL FIRE/SMOKE

= 2

= 5

= 1= 1

= 7

= 2

= 2

= 4

= 4

= 1

DUCT SMOKE DETECTOR

AREA SMOKE DETECTOR

DOOR RELEASE SMOKE DETECTOR

S O

U N

D G

E N

E R

A L

B U

IL

D

IN

G

LA

R

M

X

X

N O

T

IF

Y N

E C

E S

S A

R Y

S T

A

X

INPUT

OUTPUT

N O

T

IF

Y F

IR

E

D E

P A

R M

E N

T

IN

IT

IA

T

E S

U P

E R

V

IS

O R

Y S

IG

N

A L

T O

A

4- H

O U

R M

A N

N E

D P

O

IN

O

R

IM

M E

D

IA

T E

R E

S P

O N

S E

X C

LO

S

E A

S S

O C

IA

T

E S

M O

K E

B

R

R

IE

R D

O O

R S

O N

T H

LO

O R

X

MANUAL PULL STATION

ELEVATOR MACHINE ROOM HEAT DETECTOR

SPRINKLER WATERFLOW SWITCH

X

X

X

X

X

X

X

X

X

ELEVATOR SMOKE DETECTOR X X X

X

X

C

LO

S E

D A

M P

E R

S O

N F

P

R O

X

IM

A T

E T

O D

E T

E C

T O

R

X

X

S H

U T

D O

W N

A U

R H

A N

D

LE

S

R V

E D

B Y

T H

E D

E T

E C

T O

R

X1

1. DO NOT PROVIDE DUCT DETECTORS IN DEDICATED (100%) EXHAUST FANS, THEY SHOULD CONTINUE TO RUN.

R E

C A

LL

E

LE

V

A T

O R

X

IN

IT

IA

T

E E

LE

V

A T

O R

S H

U

D

W

N A

N D

D

IS

C O

N N

E C

LE

V A

T O

R P

O W

E R

O P

E N

L O

C K

E D

E G

R E

O

R S

O N

F

LO

O R

O F

F

IR

IG

IN

X

X

X

FIRE ALARM MATRIX

CARBON MONOXIDE DETECTOR

S O

U N

D S

P E

C

IF

IC

C

A R

B

M

N O

X

ID

E A

LA

M

WATER CONTROL VALVE TAMPER X

X

X

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE ALARM GENERAL NOTES AND

DETAILS

FA-001

-3

F A

/2

/2

.p d f

SCALE: 12" = 1'-0"

FIRE ALARM RISER DIAGRAM

12/30/2022 A R C H I T E C T S E N G I N E E R S

133 241129 of 233129 of 233

VS

CO

VS

VS

WF

VSVS

H R

H R

S P

S P

DH

DCL

F

F

S

CO

S

ID

S P

WF

VS

FAA

FACP

FATC

TPR

NAC

H R

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

E

F

H

E.8

C.3

G

MECHANICAL

ROOM

B0405

ELEVATOR PIT

B0403

CRAWL SPACE

B0400

EAST STAIR

BS1

INSULATE TO PREVENT

CONDENSATION AND DO NOT

MOUNT TO EXTERIOR WALL

FA02

FIRE ALARM SYMBOLS

DEVICES

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

MANUAL PULL STATION

SPEAKER ONLY WALL MOUNTED

EXTERIOR BELL

STROBE ONLY CEILING MOUNTED

SYMBOL DESCRIPTION

DOOR HOLDER

DOOR CLOSER

DETECTORS

GAS DETECTOR - CARBON MONOXIDE

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

FLOW DETECTOR/SWITCH

VALVE SUPERVISORY SWITCH

SWITCHES

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM TRANSPONDER CABINET

NOTIFICATION CIRCUIT POWER BOOSTER

PANELS

STROBE ONLY WALL MOUNTED

HEAT DETECTOR - RATE OF RISE

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE ALARM PLAN - BASEMENT

FA-100

-3

F A

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE ALARM PLAN - BASEMENT

N

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

KEYNOTE LEGEND

KEY DESCRIPTION

FA02 57 °C (135 °F) RATE COMPENSATION HEAT DETECTION REQUIRED 2 FT FROM

SPRINKLERS INSTALLED IN HOISTWAY PIT. SMOKE DETECTION ALSO REQUIRED AT

PIT.

12/30/2022 A R C H I T E C T S E N G I N E E R S

134 241130 of 233130 of 233

DN

P

F

F

F

F

F

FACP

S P

VS

WF

WF

VS

F

F

F

FAA

S P

H R

RL

RL

RL

RL

AIM

AIM

AIM

AIM

DH

DCL

F

F

S

CO

S

ID

S P

WF

VS

FAA

FACP

FATC

TPR

NAC

H R

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

RELOCATED FIRE ALARM PANEL

C

D

E

F

H

E.8

C.3

G

RRTP OFFICES

10426

WORKROOM

10466

MH CLINIC

EXAM/VITALS

10475

CORRIDOR

1C02

TREATMENT

OBSERVATION

10451

NURSE STATION

10452

GENDER

NEUTRAL TOILET

10447

MOTHERS ROOM

10446

GROUP ROOM C

10430

ELEVATOR

LOBBY

1C06

STORAGE

10438A

STORAGE

10430A

GROUP ROOM A

10435

STORAGE

10435A

HALL

1C10

FAMILY TOILET

10444

SPECIMEN

TOILET

10454

MH CLINIC

OFFICE

10479

STAFF TOILET

10476

MH CLINIC

OFFICE

10473

MH CLINIC

OFFICE

10471

MH CLINIC

OFFICE

10477

MH CLINIC

OFFICE

10480

MH CLINIC

MED/SUPPLY

10474

MH CLINIC

OFFICE

10470

MH CLINIC

OFFICE (FUTURE

EXAM)

10478

MH CLINIC

OFFICE

10485

MH CLINIC

OFFICE

10472

MH CLINIC

TELEMED OFFICE

10484

GENDER

NEUTRAL TOILET

10445

BUILDING DATA

10449

TREATMENT

OBSERVATION

10453

TREATMENT

CIRCULATION

10450

ADMIN OFFICE

10420

RRTP

COUNSELOR

10404

EAST STAIR

1S1

BED BUG ZAPPER

10414

RRTP SECURITY

OFFICE

10419

RRTP

COUNSELOR

10405

RRTP VITALS &

LOCKERS

10416

RRTP WAITING

10417

MAIN

ELECTRICAL

10411

WEST STAIR

1S2

MAIN CORRIDOR

1C05

GROUP ROOM B

10438

FAMILY WAITING

10465

WAITING

10424

LOUNGE

10425

VENDING

10422

INFO DESK

10442

RECEPTION

10460

VESTIBULE

10440

TRAM WALKWAY

1C20

TESTING OFFICE

10401

GROUP TESTING

10400

MH CLINIC

TELEMED OFFICE

10486

MH CLINIC

TELEMED OFFICE

10488

MH CLINIC

TELEMED OFFICE

10489

MH CLINIC

OFFICE

10487

WAITING

10443

CORRIDOR

1C04

CORRIDOR

1C07

CORRIDOR

1C08

CORRIDOR

1C11

CORRIDOR

1C12

RECEIVING

10499

EMR

10412

ELECTRICAL

CLOSET

10413

STORAGE

10415

ELECTRICAL

10415A

RRTP TOILET

10418

HAC

10464

RRTP FOYER

10427

MAIN

ELECTRICAL

10411

NEW FIRE ALARM ANNUNCIATOR

FA02

FA03

FIRE ALARM SYMBOLS

DEVICES

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

MANUAL PULL STATION

SPEAKER ONLY WALL MOUNTED

EXTERIOR BELL

STROBE ONLY CEILING MOUNTED

SYMBOL DESCRIPTION

DOOR HOLDER

DOOR CLOSER

DETECTORS

GAS DETECTOR - CARBON MONOXIDE

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

FLOW DETECTOR/SWITCH

VALVE SUPERVISORY SWITCH

SWITCHES

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM TRANSPONDER CABINET

NOTIFICATION CIRCUIT POWER BOOSTER

PANELS

STROBE ONLY WALL MOUNTED

HEAT DETECTOR - RATE OF RISE

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE ALARM PLAN - FIRST FLOOR

FA-101

-3

F A

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE ALARM PLAN - FIRST FLOOR

N

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

KEYNOTE LEGEND

KEY DESCRIPTION

FA02 57 °C (135 °F) RATE COMPENSATION HEAT DETECTION REQUIRED 2 FT FROM

SPRINKLERS INSTALLED IN HOISTWAY PIT. SMOKE DETECTION ALSO REQUIRED AT

PIT.

FA03 PROVIDE NECESSARY RELAYS AND MONITOR MODULES FOR PRIMARY AND

SECONDARY ELEVATOR RECALL, SHUNT TRIP (IF NECESSARY), AND FIREMAN'S HAT.

12/30/2022 A R C H I T E C T S E N G I N E E R S

135 241131 of 233131 of 233

W

Range

S P

F F

VS

WF

VS

WF

DH

DCL

F

F

S

CO

S

ID

S P

WF

VS

FAA

FACP

FATC

TPR

NAC

H R

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

CORRIDOR

2C02

GROUP ROOM C

20428

STORAGE

20434A

STORAGE

20428A

GROUP ROOM A

20431

STORAGE

20431A

WAITING

20427

ELEVATOR

LOBBY

2C06

BUILDING

ELECTRICAL

20408

BUILDING DATA

20447

STAFF BREAK

20449

GENDER

NEUTRAL TOILET

20445

FAMILY TOILET

20444

GENDER

NEUTRAL TOILET

20443

GENDER

NEUTRAL TOILET

20448

HVAC

20442

WAITING

20440

RECP.

WORKROOM

20424STAFF TOILET

20405

MH CLINIC

OFFICE

20478

STAFF TOILET

20466

RRTP TEACHING

KITCHEN

20454

MH CLINIC TMS

20457

RRTP KITCHEN

OFFICE

20453

MH CLINIC

OFFICE

20476

MH CLINIC

OFFICE

20474

MH CLINIC

OFFICE

20464

MH CLINIC

OFFICE

20462

MH CLINIC

OFFICE

20460

MH CLINIC

OFFICE

20461

MH CLINIC

OFFICE

20463

MH CLINIC

OFFICE

20458

MH CLINIC

OFFICE

20467

MH CLINIC

OFFICE

20469

MH CLINIC

OFFICE

20470

MH CLINIC

OFFICE

20468

MH CLINIC

OFFICE

20477

MH CLINIC

OFFICE

20479

MH CLINIC

OFFICE

20475

RRTP

COUNSELOR

20411

RRTP

COUNSELOR

20410

RRTP

COUNSELOR

20409

RRTP

COUNSELOR

20407

RRTP

COUNSELOR

20419

RRTP

COUNSELOR

20417

RRTP

COUNSELOR

20415

RRTP

COUNSELOR

20420

RRTP

COUNSELOR

20418

RRTP

COUNSELOR

20416

RRTP

COUNSELOR

20403

RRTP

COUNSELOR

20401

RRTP

COUNSELOR

20402

RRTP

COUNSELOR

20404

RRTP

COUNSELOR

20406

RRTP

COUNSELOR

20422

CORRIDOR

2C10

RECEPTION

20426

C

D

E

F

H

E.8

C.3

G

CORRIDOR

2C04

STORAGE

20446

HAC

20456

CORRIDOR

2C11

CORRIDOR

2C12

CORRIDOR

2C08

CORRIDOR

2C07

CORRIDOR

2C05

CORRIDOR

2C03

GROUP ROOM B

20434

FIRE ALARM SYMBOLS

DEVICES

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

MANUAL PULL STATION

SPEAKER ONLY WALL MOUNTED

EXTERIOR BELL

STROBE ONLY CEILING MOUNTED

SYMBOL DESCRIPTION

DOOR HOLDER

DOOR CLOSER

DETECTORS

GAS DETECTOR - CARBON MONOXIDE

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

FLOW DETECTOR/SWITCH

VALVE SUPERVISORY SWITCH

SWITCHES

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM TRANSPONDER CABINET

NOTIFICATION CIRCUIT POWER BOOSTER

PANELS

STROBE ONLY WALL MOUNTED

HEAT DETECTOR - RATE OF RISE

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE ALARM PLAN - SECOND FLOOR

FA-102

-3

F A

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE ALARM PLAN - SECOND FLOOR

N

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

136 241132 of 233132 of 233

R

S P

S P

F F

VS

WF

VS

WF

DH

DCL

F

F

S

CO

S

ID

S P

WF

VS

FAA

FACP

FATC

TPR

NAC

H R

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

ADMIN WAIT

30409

GROUP ROOM C

30436

STORAGE

30441A

STORAGE

30436A

GROUP ROOM A

30437

STORAGE

30437A

GROUP ROOM B

30441

CORRIDOR

3C07

ELEVATOR

LOBBY

3C05

BUILDING

ELECTRICAL

30416

BUILDING DATA

30451

STAFF BREAK

30453

GENDER

NEUTRAL TOILET

30449

FAMILY TOILET

30448

GENDER

NEUTRAL TOILET

30447

GENDER

NEUTRAL TOILET

30452

HVAC

30446

WAITING

30442

RRTP OFFICE

30428

STAFF TOILET

30405

OFFICE

30459

OFFICE

30457

MH CLINIC ADMIN

30464

STAFF TOILET

30472

CORRIDOR

3C10

ADMIN CUBICLES

30423

MHICM PRIVATE

COUNSEL

30476

LOUNGE

30443

CHIEF OFFICE

30417

ADMIN

CONFERENCE

30418

MHICM STORAGE

30471

MHICM PATIENT

CARE

30478

MHICM MED

ROOM

30473

MHICM CUBICLES

30479

CORRIDOR

3C11

RECP.

WORKROOM

30430

RRTP OFFICE

30402

RRTP OFFICE

30404

RRTP OFFICE

30406

RRTP OFFICE

30401

RRTP OFFICE

30403

ADMIN RECP.

30415

ADMIN OFFICE

30426

CORRIDOR

3C02

MH CLINIC

OFFICE

30470

MH CLINIC

OFFICE

30468

MH CLINIC

OFFICE

30466

MH CLINIC

OFFICE

30465

MH CLINIC

OFFICE

30467

HAC

30462

RECEPTION

30432

FIRE ALARM TRANSPONDER CABINET

C

D

E

F

H

E.8

C.3

G

WEST STAIR

3S2

EAST STAIR

3S1

CORRIDOR

3C03

CORRIDOR

3C04

CORRIDOR

3C06

CORRIDOR

3C08

CORRIDOR

3C12

OFFICE

30461

OFFICE

30460

OFFICE

30456

OFFICE

30458

STORAGE

30450

FIRE ALARM SYMBOLS

DEVICES

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

MANUAL PULL STATION

SPEAKER ONLY WALL MOUNTED

EXTERIOR BELL

STROBE ONLY CEILING MOUNTED

SYMBOL DESCRIPTION

DOOR HOLDER

DOOR CLOSER

DETECTORS

GAS DETECTOR - CARBON MONOXIDE

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

FLOW DETECTOR/SWITCH

VALVE SUPERVISORY SWITCH

SWITCHES

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM TRANSPONDER CABINET

NOTIFICATION CIRCUIT POWER BOOSTER

PANELS

STROBE ONLY WALL MOUNTED

HEAT DETECTOR - RATE OF RISE

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE ALARM PLAN - THIRD FLOOR

FA-103

-3

F A

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE ALARM PLAN - THIRD FLOOR

N

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

137 241133 of 233133 of 233

WF VS

ID

S

ID

S

ID

S

ID

S

ID

DH

DCL

F

F

S

CO

S

ID

S P

WF

VS

FAA

FACP

FATC

TPR

NAC

H R

1 1A 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

E

F

H

E.8

C.3

G

MECHANICAL

40401

FA01

FA01

FA01

FA01

FA01

FIRE ALARM SYMBOLS

DEVICES

COMBINATION OF SPEAKER/STROBE WALL MOUNTED

MANUAL PULL STATION

SPEAKER ONLY WALL MOUNTED

EXTERIOR BELL

STROBE ONLY CEILING MOUNTED

SYMBOL DESCRIPTION

DOOR HOLDER

DOOR CLOSER

DETECTORS

GAS DETECTOR - CARBON MONOXIDE

SMOKE DETECTOR - IN DUCT

SMOKE DETECTOR - PHOTOELECTRIC

FLOW DETECTOR/SWITCH

VALVE SUPERVISORY SWITCH

SWITCHES

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM CONTROL PANEL

FIRE ALARM TERMINAL CABINET

FIRE ALARM TRANSPONDER CABINET

NOTIFICATION CIRCUIT POWER BOOSTER

PANELS

STROBE ONLY WALL MOUNTED

HEAT DETECTOR - RATE OF RISE

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE ALARM PLAN - ATTIC

FA-104

-3

F A

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE ALARM PLAN - ATTIC

N

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

KEYNOTE LEGEND

KEY DESCRIPTION

FA01 PROVIDE DUCT SMOKE DETECTORS AT SUPPLY SYSTEMS HAVING CAPACITIES

GREATER THAN 2,000 CFM AND AT RETURN SYSTEMS HAVING CAPACITIES GREATER

THAN 15,000 CFM.

12/30/2022 A R C H I T E C T S E N G I N E E R S

138 241134 of 233134 of 233

B

FX01

FX03

C

D

E

F

H

E.8

C.3

G

6" F

6" F

6" F

UP TO SPRINKLER RISER

UP TO SPRINKLER RISER

FX01

FX05

FX07 FX07

FX07

FX07

FX09

SPRINKLER PROVIDED

UNDERNEATH ACCESSIBLE

LANDING

FX12

FX12

1. THIS FACILITY IS TO BE PROTECTED THROUGHOUT WITH AN AUTOMATIC WET-PIPE

SPRINKLER SYSTEM PER THE PROJECT REQUIREMENTS BY THE OWNER.

2. THE DESIGN AND INSTALLATION OF THE WET-PIPE SPRINKLER SYSTEM SHALL BE

IN ACCORDANCE WITH NFPA 13 (2019 EDITION), NFPA 14 (2016 EDITION), NFPA 24

(2019 EDITION), THE VA FIRE PROTECTION DESIGN MANUAL, AND THE DESIGN

DOCUMENTS.

3. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ALL PIPE ROUTING AND

DETAILS SHOWN SHALL BE CONFIRMED BY THE FIRE PROTECTION CONTRACTOR

AND FULLY COORDINATED WITH ALL DISCIPLINES. THE FIRE PROTECTION

CONTRACTOR SHALL FURNISH COMPLETE CONSTRUCTION SHOP DRAWINGS

SHOWING ALL SPRINKLER, PIPE, VALVE AND DRAIN LOCATIONS.

4. THERE ARE TWO SPRINKLER ZONES PER OCCUPIED FLOOR AND ONE IN THE

ATTIC. THE ZONE LAYOUT WILL REMAIN AND BE ALTERED TO ACCOMMODATE THE

ADDITION.

5. SPRINKLER SYSTEMS SHALL BE HYDRAULICALLY CALCULATED IN ACCORDANCE

WITH NFPA 13.

6. EXISTING WET-MANUAL CLASS I STANDPIPES AND SPRINKLER RISERS ARE

LOCATED IN THE EXIT STAIRWELLS. EXISTING STANDPIPES AND HOSE VALVE

LOCATIONS SHALL REMAIN.

7. A NEW DOUBLE CHECK BACKFLOW PREVENTER SHALL BE INSTALLED IN THE SUB-

BASEMENT AT THE LOCATION OF THE INCOMING WATER.

8. CHROME QUICK RESPONSE SEMI-RECESSED PENDENT SPRINKLERS SHALL BE

INSTALLED IN ALL AREAS WITH FINISHED CEILINGS. IN AREAS WITHOUT FINISHED

CEILINGS BRASS UPRIGHT SPRINKLERS SHALL BE INSTALLED.

9. SPRINKLERS ARE SHOWN IN AREAS WITH FINISHED CEILINGS FOR COORDINATION

PURPOSES. INSTALLING CONTRACTOR TO VERIFY FINAL LAYOUT COMPLIANT WITH

VA STANDARDS AND NFPA 13.

10. IN LOCATIONS WITH ACOUSTICAL CEILING TILES SPRINKLERS SHALL BE LOCATED

IN THE CENTER OF TILES.

11. THE MAXIMUM COVERAGE PER SPRINKLER IS 225 SQUARE FEET FOR LIGHT

HAZARD AREAS AND 130 SQUARE FEET FOR ORDINARY HAZARD AREAS.

12. ALL HANGERS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA

13.

13. ALL VALVES (DRAIN, INSPECTOR'S TEST, CONTROL) SHALL BE IDENTIFIED AS

REQUIRED BY NFPA 13.

14. PROVISIONS FOR DRAINING OF SPRINKLER PIPING SHALL BE PROVIDED IN

ACCORDANCE WITH NFPA 13.

15. ALL DRAINS AND TEST CONNECTIONS SHALL DISCHARGE TO A SAFE LOCATION

OUTSIDE THE BUILDING.

16. LOCATIONS SUBJECT TO FREEZING SHALL BE PROTECTED WITH LISTED DRY

SPRINKLER ASSEMBLIES.

17. THE ATTIC SPACE IS TO BE CONDITIONED AND PROTECTED WITH A WET PIPE

SYSTEM.

18. SPRINKLER TEMPERATURE RATINGS NEAR HVAC DIFFUSERS SHALL BE IN

ACCORDANCE WITH NFPA 13, SECTION 8.3.2.

19. COMMUNICATIONS ROOMS AND MECHANICAL ROOMS SHALL BE PROTECTED

USING INTERMEDIATE TEMPERATURE RATED SPRINKLERS.

20. PIPE 2" AND LESS IN DIAMETER SHALL BE SCHEDULE 40, PIPE GREATER THAN 2" IN

DIAMETER SHALL BE SCHEDULE 10.

21. PIPE SIZES INDICATED ON DRAWINGS ARE PRELIMINARY. FINAL SIZES SHALL BE

DETERMINED BY INSTALLING CONTRACTOR HYDRAULIC CALCULATIONS.

22. TO AID IN PREVENTION OF PIPE CORROSION INSTALL AUTOMATIC AIR VENTING

NEAR A HIGH POINT ON EACH SYSTEM PER NFPA 13.

23. THE CONTRACTOR SHALL PERFORM A HYDRANT FLOW TEST PRIOR TO SYSTEM

CALCULATION TO DETERMINE AVAILABLE WATER PRESSURE AND FLOW BUT,

SHALL USE THE FOLLOWING FLOW TEST DATA AS THE BASIS OF THEIR DESIGN

UNLESS THE CONFIRMING FLOW TEST DATA IS WORSE:

STATIC: 87 PSI

RESIDUAL: 62 PSI

FLOW: 1033 GPM

TEST DATE: FALL 2018 BY TOMAH VA F.D.

FIRE SUPPRESSION GENERAL NOTES

FIRE SUPPRESSION HATCH LEGEND

ORDINARY HAZARD I

DENSITY: 0.15 GPM/SQFT OVER 1500 SQFT

LIGHT HAZARD

DENSITY: 0.10 GPM/SQFT OVER 1500 SQFT

ORDINARY HAZARD II

DENSITY: 0.20 GPM/SQFT OVER 1500 SQFT

SPRINKLER HEAD - CONCEALED PENDANT

SPRINKLER HEAD - UPRIGHT

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE SUPPRESSION PLAN -

BASEMENT

FX-100

-3

F X

/2

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE SUPPRESSION PLAN - BASEMENT

N

KEYNOTE LEGEND

KEY DESCRIPTION

FX01 EXISTING STANDPIPES AND BULK FEED PIPING TO STANDPIPES SHALL REMAIN.

EXISTING 2-1/2" HOSE CONNECTIONS SHALL REMAIN

FX03 EXISTING PIPING TO REMOTE FIRE DEPARTMENT CONNECTION TO REMAIN.

FX05 INSTALL DOUBLE CHECK BACKFLOW PREVENTER AT LOCATION OF PREVIOUS

VALVES.

FX07 NO SPRINKLER PROTECTION REQUIRED IN GREY SHADED AREA OF BASEMENT.

LIMITED ACCESS NON-COMBUSTIBLE SPACES.

FX09 INSTALL NEW SPRINKLERS AND ASSOCIATED PIPING IN BASEMENT. INSTALL

SPRINKLERS UNDER OBSTRUCTIONS PER NFPA 13.

FX12 SPRINKLER PROTECTION REQUIRED AT ELEVATOR HOISTWAY PIT. RATE HEAT

DETECTION REQUIRED 2 FT FROM SPRINKLERS.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

205 241135 of 233135 of 233

DN

A

B

EAST SPRINKLER ZONE WEST SPRINKLER ZONE

FX01

FX01

C

D

E

F

H

E.8

C.3

G

3" F

1 1/2" F

1 1/2" F

3" F

3" F

1 1/2" F

1 1/2" F

1 1/2" F

3" F

FX06

FX06

RRTP OFFICES

10426

WORKROOM

10466

MH CLINIC

EXAM/VITALS

10475

CORRIDOR

1C02

TREATMENT

OBSERVATION

10451

NURSE STATION

10452

GENDER

NEUTRAL TOILET

10447

MOTHERS ROOM

10446

GROUP ROOM C

10430

ELEVATOR

LOBBY

1C06

STORAGE

10438A

STORAGE

10430A

GROUP ROOM A

10435

STORAGE

10435A

HALL

1C10

FAMILY TOILET

10444

SPECIMEN

TOILET

10454

MH CLINIC

OFFICE

10479

STAFF TOILET

10476

MH CLINIC

OFFICE

10473

MH CLINIC

OFFICE

10471

MH CLINIC

OFFICE

10477

MH CLINIC

OFFICE

10480

MH CLINIC

MED/SUPPLY

10474

MH CLINIC

OFFICE

10470

MH CLINIC

OFFICE (FUTURE

EXAM)

10478

MH CLINIC

OFFICE

10485

MH CLINIC

OFFICE

10472

MH CLINIC

TELEMED OFFICE

10484

GENDER

NEUTRAL TOILET

10445

BUILDING DATA

10449

TREATMENT

OBSERVATION

10453

TREATMENT

CIRCULATION

10450

ADMIN OFFICE

10420

RRTP

COUNSELOR

10404

EAST STAIR

1S1

BED BUG ZAPPER

10414

RRTP SECURITY

OFFICE

10419

RRTP

COUNSELOR

10405

RRTP VITALS &

LOCKERS

10416

RRTP WAITING

10417

MAIN

ELECTRICAL

10411

WEST STAIR

1S2

MAIN CORRIDOR

1C05

GROUP ROOM B

10438

FAMILY WAITING

10465

WAITING

10424

LOUNGE

10425

VENDING

10422

INFO DESK

10442

RECEPTION

10460

VESTIBULE

10440

TRAM WALKWAY

1C20

TESTING OFFICE

10401

GROUP TESTING

10400

MH CLINIC

TELEMED OFFICE

10486

MH CLINIC

TELEMED OFFICE

10488

MH CLINIC

TELEMED OFFICE

10489

MH CLINIC

OFFICE

10487

WAITING

10443

CORRIDOR

1C04

CORRIDOR

1C07

CORRIDOR

1C08

CORRIDOR

1C11

CORRIDOR

1C12

RECEIVING

10499

EMR

10412

ELECTRICAL

CLOSET

10413

STORAGE

10415

ELECTRICAL

10415A

RRTP TOILET

10418

HAC

10464

RRTP FOYER

10427

MAIN

ELECTRICAL

10411

SPRINKLER PROVIDED

UNDERNEATH ACCESSIBLE

LANDING

FX12

FX12

FX13

FX13

FX13

FX13

FX13

FX13

FIRE SUPPRESSION HATCH LEGEND

ORDINARY HAZARD I

DENSITY: 0.15 GPM/SQFT OVER 1500 SQFT

LIGHT HAZARD

DENSITY: 0.10 GPM/SQFT OVER 1500 SQFT

ORDINARY HAZARD II

DENSITY: 0.20 GPM/SQFT OVER 1500 SQFT

SPRINKLER HEAD - CONCEALED PENDANT

SPRINKLER HEAD - UPRIGHT

1. THIS FACILITY IS TO BE PROTECTED THROUGHOUT WITH AN AUTOMATIC WET-PIPE

SPRINKLER SYSTEM PER THE PROJECT REQUIREMENTS BY THE OWNER.

2. THE DESIGN AND INSTALLATION OF THE WET-PIPE SPRINKLER SYSTEM SHALL BE

IN ACCORDANCE WITH NFPA 13 (2019 EDITION), NFPA 14 (2016 EDITION), NFPA 24

(2019 EDITION), THE VA FIRE PROTECTION DESIGN MANUAL, AND THE DESIGN

DOCUMENTS.

3. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ALL PIPE ROUTING AND

DETAILS SHOWN SHALL BE CONFIRMED BY THE FIRE PROTECTION CONTRACTOR

AND FULLY COORDINATED WITH ALL DISCIPLINES. THE FIRE PROTECTION

CONTRACTOR SHALL FURNISH COMPLETE CONSTRUCTION SHOP DRAWINGS

SHOWING ALL SPRINKLER, PIPE, VALVE AND DRAIN LOCATIONS.

4. THERE ARE TWO SPRINKLER ZONES PER OCCUPIED FLOOR AND ONE IN THE

ATTIC. THE ZONE LAYOUT WILL REMAIN AND BE ALTERED TO ACCOMMODATE THE

ADDITION.

5. SPRINKLER SYSTEMS SHALL BE HYDRAULICALLY CALCULATED IN ACCORDANCE

WITH NFPA 13.

6. EXISTING WET-MANUAL CLASS I STANDPIPES AND SPRINKLER RISERS ARE

LOCATED IN THE EXIT STAIRWELLS. EXISTING STANDPIPES AND HOSE VALVE

LOCATIONS SHALL REMAIN.

7. A NEW DOUBLE CHECK BACKFLOW PREVENTER SHALL BE INSTALLED IN THE SUB-

BASEMENT AT THE LOCATION OF THE INCOMING WATER.

8. CHROME QUICK RESPONSE SEMI-RECESSED PENDENT SPRINKLERS SHALL BE

INSTALLED IN ALL AREAS WITH FINISHED CEILINGS. IN AREAS WITHOUT FINISHED

CEILINGS BRASS UPRIGHT SPRINKLERS SHALL BE INSTALLED.

9. SPRINKLERS ARE SHOWN IN AREAS WITH FINISHED CEILINGS FOR COORDINATION

PURPOSES. INSTALLING CONTRACTOR TO VERIFY FINAL LAYOUT COMPLIANT WITH

VA STANDARDS AND NFPA 13.

10. IN LOCATIONS WITH ACOUSTICAL CEILING TILES SPRINKLERS SHALL BE LOCATED

IN THE CENTER OF TILES.

11. THE MAXIMUM COVERAGE PER SPRINKLER IS 225 SQUARE FEET FOR LIGHT

HAZARD AREAS AND 130 SQUARE FEET FOR ORDINARY HAZARD AREAS.

12. ALL HANGERS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA

13.

13. ALL VALVES (DRAIN, INSPECTOR'S TEST, CONTROL) SHALL BE IDENTIFIED AS

REQUIRED BY NFPA 13.

14. PROVISIONS FOR DRAINING OF SPRINKLER PIPING SHALL BE PROVIDED IN

ACCORDANCE WITH NFPA 13.

15. ALL DRAINS AND TEST CONNECTIONS SHALL DISCHARGE TO A SAFE LOCATION

OUTSIDE THE BUILDING.

16. LOCATIONS SUBJECT TO FREEZING SHALL BE PROTECTED WITH LISTED DRY

SPRINKLER ASSEMBLIES.

17. THE ATTIC SPACE IS TO BE CONDITIONED AND PROTECTED WITH A WET PIPE

SYSTEM.

18. SPRINKLER TEMPERATURE RATINGS NEAR HVAC DIFFUSERS SHALL BE IN

ACCORDANCE WITH NFPA 13, SECTION 8.3.2.

19. COMMUNICATIONS ROOMS AND MECHANICAL ROOMS SHALL BE PROTECTED

USING INTERMEDIATE TEMPERATURE RATED SPRINKLERS.

20. PIPE 2" AND LESS IN DIAMETER SHALL BE SCHEDULE 40, PIPE GREATER THAN 2" IN

DIAMETER SHALL BE SCHEDULE 10.

21. PIPE SIZES INDICATED ON DRAWINGS ARE PRELIMINARY. FINAL SIZES SHALL BE

DETERMINED BY INSTALLING CONTRACTOR HYDRAULIC CALCULATIONS.

22. TO AID IN PREVENTION OF PIPE CORROSION INSTALL AUTOMATIC AIR VENTING

NEAR A HIGH POINT ON EACH SYSTEM PER NFPA 13.

23. THE CONTRACTOR SHALL PERFORM A HYDRANT FLOW TEST PRIOR TO SYSTEM

CALCULATION TO DETERMINE AVAILABLE WATER PRESSURE AND FLOW BUT,

SHALL USE THE FOLLOWING FLOW TEST DATA AS THE BASIS OF THEIR DESIGN

UNLESS THE CONFIRMING FLOW TEST DATA IS WORSE:

STATIC: 87 PSI

RESIDUAL: 62 PSI

FLOW: 1033 GPM

TEST DATE: FALL 2018 BY TOMAH VA F.D.

FIRE SUPPRESSION GENERAL NOTES

Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:PROFESSIONAL SEAL:

Revisions: Date: CONSULTANT:

23456789101112131415

B

C

D

E

F

G

H

I

J

123456789101112131415

/8

/4

/8

/2

/4

-1

/2

Drawing of

Architect:

CB DESIGN GROUP, INC

421 King St., Suite 301 Alexcandria, VA 22314 POC: Wes Bridges, AIA 703.772.4213

Consultant:

LEO A DALY

730 Second Avenue South Suite 1300 Minneapolis, MN 612.338.8741 POC: Todd Thelen

A R C H I T E C T S E N G I N E E R S

TOMAH VAMC

TOMAH, WISCONSIN

DECEMBER 15, 2022

676-325

CSSDLO

EXPAND AND RENOVATE B404 FOR

OUTPATIENT MENTAL HEALTH

BID SET

FIRE SUPPRESSION PLAN - FIRST

FLOOR

FX-101

-3

F X

/0

/2

.p d f

SCALE: 1/8" = 1'-0"

FIRE SUPPRESSION PLAN - FIRST FLOOR

N

KEYNOTE LEGEND

KEY DESCRIPTION

FX01 EXISTING STANDPIPES AND BULK FEED PIPING TO STANDPIPES SHALL REMAIN.

EXISTING 2-1/2" HOSE CONNECTIONS SHALL REMAIN

FX06 INSTALL NEW FLOOR CONTROL ASSEMBLIES AT EACH SYSTEM.

FX12 SPRINKLER PROTECTION REQUIRED AT ELEVATOR HOISTWAY PIT. RATE HEAT

DETECTION REQUIRED 2 FT FROM SPRINKLERS.

FX13 CEILING IN THIS ROOM TO REMAIN, CONTRACTOR TO REMOVE AND REPLACE

TILES AS NECESSARY TO INSTALL NEW SPRINKLER HEADS.

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

12/30/2022 A R C H I T E C T S E N G I N E E R S

140 241136 of 233136 of 233

B

FX01

FX01

EAST SPRINKLER ZONE WEST SPRINKLER ZONE

C

D

E

F

H

E.8

C.3

G

3" F

1 1/2" F 3" F

3" F

1 1/2" F

3" F

1 1/2" F

3" F

1 1/2" F

3" F

FX06

FX06

CORRIDOR

2C02

GROUP ROOM C

20428

STORAGE

20434A

STORAGE

20428A

GROUP ROOM A

20431

STORAGE

20431A

WAITING

20427

ELEVATOR

LOBBY

2C06

BUILDING

ELECTRICAL

20408

BUILDING DATA

20447

STAFF BREAK

20449

GENDER

NEUTRAL TOILET

20445

FAMILY TOILET

20444

GENDER

NEUTRAL TOILET

20443

GENDER

NEUTRAL TOILET

20448

HVAC

20442

WAITING

20440

RECP.

WORKROOM

20424

STAFF TOILET

20405

MH CLINIC

OFFICE

20478

STAFF TOILET

20466

RRTP TEACHING

KITCHEN

20454

MH CLINIC TMS

20457

RRTP KITCHEN

OFFICE

20453

MH CLINIC

OFFICE

20476

MH CLINIC

OFFICE

20474

MH CLINIC

OFFICE

20464

MH CLINIC

OFFICE

20462

MH CLINIC

OFFICE

20460

MH CLINIC

OFFICE

20461

MH CLINIC

OFFICE

20463

MH CLINIC

OFFICE

20458

MH CLINIC

OFFICE

20467

MH CLINIC

OFFICE

20469

MH CLINIC

OFFICE

20470

MH CLINIC

OFFICE

20468

MH CLINIC

OFFICE

20477

MH CLINIC

OFFICE

20479

MH CLINIC

OFFICE

20475

RRTP

COUNSELOR

20411 RRTP

COUNSELOR

20410

RRTP

COUNSELOR

20409

RRTP

COUNSELOR

20407

RRTP

COUNSELOR

20419

RRTP

COUNSELOR

20417

RRTP

COUNSELOR

20415

RRTP

COUNSELOR

20420

RRTP

COUNSELOR

20418

RRTP

COUNSELOR

20416

RRTP

COUNSELOR

20403

RRTP

COUNSELOR

20401

RRTP

COUNSELOR

20402

RRTP

COUNSELOR

20404

RRTP

COUNSELOR

20406 RRTP

COUNSELOR

20422

CORRIDOR

2C10

RECEPTION

204…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .