Attachment 6 - Final Drawing Set - 5 of 8.pdf

PDF 11 MB Posted

Attached to
Project 573A4-21-700 EHRM Infrastructure Upgrades construction project at the Lake City, FL VAMC
Solicitation number
36C77625B0006
Issued by

About this file

This file is a detailed set of technology infrastructure upgrade drawings for the Lake City VA Medical Center. The project, numbered 573A4-21-700, involves comprehensive telecommunications infrastructure upgrades across multiple buildings, including replacing existing network cabling, installing new data outlets, upgrading fiber optic backbone cabling, and implementing new wireless access points and security cameras. The drawings specify technical details for basement, first floor, and other levels of Buildings 64, 38, 19, 82, 06, 62, 74, 27, 37, 18, 42, 44, and 92.

The project is a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with a construction value between $20 million and $50 million. The scope includes replacing existing telecommunications infrastructure with new Category 6A cabling, installing new patch panels, upgrading wireless networks, and implementing new fiber optic backbone cabling. The technical specifications require careful coordination of cable routing, penetration of fire-rated barriers, and minimal network downtime during the transition. The work will be performed for the Department of Veterans Affairs Technology Acquisition Center Austin at the Lake City VA Medical Center located in Lake City, Florida.

View the file

Other files

File Type Posted
Online Bid Opening Meeting Info.docx DOCX document
Amendment 5 - 36C77625B0006 0005 6-30-25.pdf PDF
Construction Wage Rates - Columbia 6-27-2025.pdf PDF
Brand Name Justification - Lake City - Rev 2 0 - Redacted.pdf PDF
Amendment 4 - 36C77625B0006 0004 6-25-25.pdf PDF
Brand Name Justification - Lake City EHRM - SIGNED_Redacted.pdf PDF
Amendment 3 - 36C77625B0006 0003 6-11-25.pdf PDF
573A4-21-700 Lake City - RFI TRACKING SHEET REV2 36C77625B0006 6-10-25.xlsx XLSX spreadsheet
573A4-21-700 Lake City - Addendum No. 1.pdf PDF
260526-EDITED Grnd shop marked up.docx DOCX document
260533-EDITED Raceway shop marked up.docx DOCX document
260519-EDITED Low Volt cond cab shop marked updocx.docx DOCX document
262726-EDITED Wire Dev shop marked up.docx DOCX document
Construction Wage Rates - Columbia 5-2-2025.pdf PDF
262416-EDITED Panelboards shop marked up.docx DOCX document
Amendment 2 - 36C77625B0006 0002 5-27-2025.pdf PDF
Site Visit Sign-in - 573A4-21-700 Attendance 250423.pdf PDF
Amendment 1 - 36C77625B0006 0001 4-24-25.pdf PDF
Attachment 15 - Construction Wage Rates - Columbia.pdf PDF
Attachment 8 - Final Drawing Set - 7a of 8.pdf PDF
Attachment 4 - Final Drawing Set - 3 of 8.pdf PDF
Attachment 14 - PreConstruction Risk Assessment - Lake City.docx DOCX document
Attachment 5 - Final Drawing Set - 4 of 8.pdf PDF
Attachment 9 - Final Drawing Set - 7b of 8.pdf PDF
Attachment 10 - Final Drawing Set - 7c of 8.pdf PDF
Attachment 7 - Final Drawing Set - 6 of 8.pdf PDF
Attachment 12 - Final Drawing Set - 8 of 8.pdf PDF
Attachment 1 - Final Specs Set - R4.pdf PDF
Attachment 13 - Asbestos and Lead Paint Survey Report.pdf PDF
Attachment 11 - Final Drawing Set - 7d of 8.pdf PDF
Attachment 17 - Site Visit Instructions.pdf PDF
Attachment 3 - Final Drawing Set - 2 of 8.pdf PDF
Attachment 16 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 2 - Final Drawing Set - 1 of 8.pdf PDF
IFB 36C77625B0006.pdf PDF
Attachment 18 - RFI TRACKING SHEET - SOLICITATION 36C77625B0006 - Project 573A4-21-700.xlsx XLSX spreadsheet
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXTERIOR ELEVATION

INTERIOR ELEVATION

SECTION/DETAIL NUMBER

DRAWING NUMBER

EQUIPMENT TAG

COLUMN GRID

NOTE

WINDOW OPENING

DOOR OPENING

ROOM NAME

ROOM NUMBER

WALL TYPE

CEILING HEIGHT

FINISH DESIGNATION

X

10'-8"

X X

XX.X-X

XX

X

1/A101

X

A101

XX

TOILET ACCESSORY TAGX SIGNAGE TAG

A101

SIM

X

SE Pine Dr

SE Oak St

SE D

ivision Ave

SE Baya Dr

S M ar io n Av e

SW Baya Dr

SW

M ai n

Bl vd

SW

M cF ar la ne

A ve

W Duval St

NW Lake Jeffery Rd

NE Bonds St

NE Track Dr

E Duval St

SE

C ou nt ry C lu b

R d

SW Bascom Norris Dr

N M ar io n Av e N E

Pa tte rs on

A ve

NE Bascom Norris Dr

Alligator Lake

La ke

H am bu rg

Lake City Veteran's Affairs Medical Center

N

B38

S1

B85

B64

B82

B19

B84

B03

B91

B86

B06

B83 B62

B74

B95

B92

B05

B18

B78

B37

B27

B70

B93

B42

B44

B41

SE Baya Dr

S M ar io n Av e

SE D

ivision Ave

B94

B69

B79

B66

S T

AT

E

OF FLOR

I D A

R

EGISTERED ARCH

IT

EC

T

J A

SO

N H. ROS

S

AR101907

VA Project No.

RDC/JPA Project No.

Department of Veterans Affairs Medical Center

ABOVE GROUP INC.

MECHANICAL ELECTRICAL PLUMBING TECHNOLOGY

305 EAST DRIVE, SUITE H

MELBOURNE, FL 32904

321.345.9026 P

ARCHITECTURE PLANNING INTERIOR DESIGN

524 FERNWOOD AVENUE

ALTAMONTE SPRINGS, FLORIDA 32701

407.830.6522 P

RDC / JPA ARCHITECTURE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

TERRACON

ENVIRONMENTAL

16200 NW 59TH AVE, SUITE 201

MIAMI LAKES, FL 33014

786.329.4062 P

/2

4/

:2 7:

P

M

LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

10/25/2024

COVER SHEET - VOLUME 02

G004

ACKR

573A4-21-700

LAKE CITY FL

LAKE CITY VAMC EHRM INFRASTRUCTURE

UPGRADES DESIGN

619 S. MARION AVE, LAKE CITY FL, 32025 PROJECT #: 573A4-21-700

STATION CHIEF - EDWIN BURNETT

100% CONSTRUCTION

DOCUMENTS

22011

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

GENERAL CONSTRUCTION NOTES

* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS

TO THE CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).

1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE

SAFETY CODE, INTERNATIONAL BUILDING CODE, AND OTHER

CODES AS IDENTIFIED IN VHA PROGRAM GUIDE PG-18-3, TOPIC

01, CODES, STANDARDS AND EXECUTIVE ORDERS WHICH CAN

BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,

TECHNICAL INFORMATION LIBRARY WEBSITE.

2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE

LATEST ARCHITECTURAL BARRIERS ACT ACCESSIBILITY

STANDARD (ABAAS) AND DEPARTMENT OF VETERANS AFFAIRS

BARRIER FREE DESIGN GUIDE PG-18-13 WHICH CAN BE FOUND

ON THE DEPARTMENT OF VETERANS AFFAIRS TECHNICAL

INFORMATION LIBRARY WEBSITE.

3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE

AND ACCEPT EXISTING CONDITIONS PRIOR TO BIDDING. SITE

VISITS TO BE COORDINATED WITH THE CONTRACTING

OFFICER'S REPRESENTATIVE.

4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH,

TO MATCH ADJACENT EXISTING SURFACES, ANY EXISTING

MATERIALS TO REMAIN THAT ARE DAMAGED DURING THE

COURSE OF DEMOLITION OR NEW WORK.

5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR

INSTALLATION OF NEW WORK, CONTRACTOR SHALL REPAIR

EXISTING CONSTRUCTION TO REMAIN OR PROVIDE NEW

CONSTRUCTION TO MATCH EXISTING ADJACENT SURFACES TO

REMAIN.

6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL

CONDITIONS AND DIMENSIONS PRIOR TO ORDERING,

FABRICATING OR INSTALLING NEW MATERIALS.

7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL

EQUIPMENT, ETC. TO BE INSTALLED AS PART OF THIS

PROJECT, AND WHERE NECESSARY, MAKE SPECIAL

PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO

FIT THROUGH FINISHED OPENINGS.

8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET

ACCESSORIES, HAND RAILS, BUMPER RAILS, SHELVING,

CASEWORK, MOUNTING BRACKETS AND OTHER WALL

MOUNTED ITEMS, AS INDICATED IN THE CONTRACT

DOCUMENTS AND AS RECOMMENDED BY PRODUCT

MANUFACTURERS. ALL WOOD BLOCKING SHALL BE FIRE

RETARDANT TREATED.

9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES

UNLESS SPECIFICALLY NOTED OTHERWISE. IF NO FINISH IS

INDICATED AT A PARTICULAR SURFACE, CONTRACTOR SHALL

PROVIDE FINISH(S) AS INDICATED AT SIMILAR CONDITIONS.

10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY

OPERATIONAL SYSTEMS WHICH COMPLY WITH STATED CODES

AND REGULATIONS. WHERE THE OMISSION OF A PART OR

ELEMENT OF A SYSTEM WOULD RESULT IN THE

NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM,

CONTRACTOR SHALL INCLUDE SAID PART OR ELEMENT AS

PART OF THE WORK.

11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE

OR FIRE RATED WALLS SHALL BE SMOKE/FIRE STOPPED AS

REQUIRED BY THE RATING OF THE WALL.

12. FIRE PROTECTION CONTRACTOR'S SPRINKLER DESIGN WILL BE

SUBJECT TO AN INDEPENDENT REVIEW BY A CERTIFIED FIRE

PROTECTION ENGINEER RETAINED BY THE OWNER. THE FIRE

PROTECTION CONTRACTOR IS RESPONSIBLE FOR MAKING ANY

REQUIRED CHANGES TO THE DESIGN AS IDENTIFIED BY THE

OWNER'S FIRE PROTECTION ENGINEER AS NECESSARY FOR

COMPLIANCE WITH SPECIFIED NFPA REQUIREMENTS.

13. CONTRACTOR IS RESPONSIBLE FOR IDENTIFICATION AND

REMOVAL OF HAZARDOUS MATERIALS ENCOUNTERED DURING

CONSTRUCTION.

Scale: 1" = 100'-0"

REGIONAL MAP

Scale: 1" = 50'-0"

VICINITY MAP

Revisions Date 10/25/202412/31/2024

S T

AT

E

OF FLOR

I D A

R

EGISTERED ARCH

IT

EC

T

J A

SO

N H. ROS

S

AR101907

VA Project No.

RDC/JPA Project No.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Office of Construction and Facilities Management

/2

5/

:0 8:

P

M

LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

10/25/2024

DRAWING INDEX

G005

ACKR

573A4-21-700

LAKE CITY FL

STATION CHIEF - EDWIN BURNETT

100% CONSTRUCTION

DOCUMENTS

22011

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

G001 COVER SHEET - VOLUME 01

G002 DRAWING INDEX

G003 CODE DATA

A1.B BASEMENT - ZONES

A1.1 FIRST FLOOR - ZONES

A1.2 SECOND FLOOR - ZONES

A1.3 THIRD FLOOR - ZONES

A1.4 FOURTH FLOOR - ZONES

A1.B.1 BLDG 64 - LV B - ZONES 2,3,6

A1.B.2 BLDG 19 & 82 - LV B - ZONES 7 & 9

A1.B.3 BLDG 66 - LV B - ZONE 11

A1.1.1 BLDG 38 & 64 - LV 1 - ZONES 2,3,5

A1.1.2 BLDG 19, 64, 82 - LV 1 - ZONES 6,7,9

A1.2.1 BLDG 38 & 64 - LV 2 - ZONES 2,3,5

A1.2.2 BLDG 82 - LV 2 - ZONE 9

A1.3.1 BLDG 38, 64, 82 - LV 3 - ZONES 3,5,9

A1.4.1 BLDG 64 - LV 4 - ZONE 3

A1.1.3 BLDG 62 & 74 - ZONE 12 & 13

A1.1.4 BLDGS 27 & 37 - ZONE 14

A1.1.5 BLDG 18, 42, 44 - ZONE 15

A1.1.6 BLDG 92 - ZONE 15

A600 SCHEDULES, DETAILS & WALL TYPES

S-001 STRUCTURAL GENERAL NOTES AND ABBREVIATIONS

SS1.B.3 BLDG 64A - LV B - ZONE 3 - STRUCTURAL FOUNDATION PLAN

SS1.B.11A BLDG 64A - LV B - ZONE 11 - STRUCTURAL FOUNDATION PLAN

SS1.B.11B BLDG 66 - LV B - ZONE 11 - STRUCTURAL FOUNDATION PLAN

SS1.B.12B BLDG 62 - LV B - ZONE 12B - STRUCTURAL FOUNDATION PLAN

SS1.B.13 BLDG 74 - LV B - ZONE 13 - STRUCTURAL FOUNDATION PLAN

SS1.1.11 BLDG 06 - LV 1 - ZONE 11 - STRUCTURAL FOUNDATION PLAN

SS1.1.14A BLDG 27 - LV 1 - ZONE 14 - STRUCTURAL FOUNDATION

SS1.1.14B BLDG 37 - LV 1 - ZONE 14 - STRUCTURAL FOUNDATION PLAN

SS1.1.15 BLDG 18, 42, 44, & 92 - LV1 - ZONE 15 - STRUCT FOUNDATION PLAN

SS1.2.3 BLDG 91 - LV 2 - ZONE 3 - STRUCTURAL FRAMING PLAN

SS1.2.11 BLDG 66 - LV 2 - ZONE 11 STRUCTURAL CEILING SUPPORT

S-301 DETAILS AND SECTIONS

FA001 FIRE ALARM LEGENDS & SYMBOLS

FA101 BASEMENT - ZONES - NEW

FA400 ENLARGED DATA CENTER

FP-001 FIRE PROTECTION NOTES, LEGENDS, & SYMBOLS

FP1.B BASEMENT - ZONES - FIRE PROTECTION

FP1.B.1 FIRE PROTECTION PLANS - LV B - BLDG 19, 62, 64 & 82

FP1.B.2 FIRE PROTECTION PLANS - LV B - BLDG 66

FP1.1 FIRST FLOOR - ZONES - FIRE PROTECTION

FP1.1.1 FIRE PROTECTION PLANS - LV 1 - BLDG 6, 19, 38 & 64

FP1.1.2 FIRE PROTECTION PLANS - LV 1 - BLDG 18, 27, 37, 42, 44, 62, 82 & 92

FP1.2 SECOND FLOOR - ZONES - FIRE PROTECTION

FP1.2.1 FIRE PROTECTION PLANS - LV 2 - BLDG 38, 62, 64, 82

FP1.3 THIRD FLOOR - ZONES - FIRE PROTECTION

FP1.3.1 FIRE PROTECTION PLANS - LV 3 - BLDG 38, 64 & 82

FP1.4 FOURTH FLOOR - ZONES - FIRE PROTECTION

FP1.4.1 FIRE PROTECTION PLANS - LV 3 - BLDG 64

M-001 MECHANICAL NOTES, LEGENDS, & SYMBOLS

MH1.B BASEMENT - ZONES - MECHANICAL

MH1.B.1 BLDG 64 - LV B - ZONES 2 & 3 - MECHANICAL PLANS

MH1.B.2 BLDG 19 & 64 - LV B - ZONES 6 & 7 - MECHANICAL PLANS

MH1.B.3 BLDG 74 & 82 - LV B - ZONES 9 & 12a - MECHANICAL PLANS

MH1.B.4 BLDG 66 - LV B - ZONE 11 - MECHANICAL PLANS

MH1.1 FIRST FLOOR - ZONES - MECHANICAL

MH1.1.1 BLDG 64-A, B, & 91 - LV 1 - ZONE 2 & 3 - MECHANICAL PLANS

MH1.1.2 BLDG 38 & 64 - LV 1 - ZONE 5 & 6 - MECHANICAL PLANS

MH1.1.3 BLDG 19 & 82 - LV 1 - ZONE 7 & 9 - MECHANICAL PLANS

MH1.1.4 BLDG 6, 27, 37, 62 - LV 1 - ZONES 11, 12, 14 - MECHANICAL PLANS

MH1.1.5 BLDG 18, 42, 44, 92 - LV 1 - ZONE 15 - MECHANICAL PLANS

MH1.2 SECOND FLOOR - ZONES - MECHANICAL

MH1.2.1 BLDG 64 - LV 2 - ZONE 2 & 3 - MECHANICAL PLANS

MH1.2.2 BLDG 38, 62, 82 - LV 2 - ZONES 5, 9, 12 - MECHANICAL PLANS

MH1.3 THIRD FLOOR - ZONES - MECHANICAL

MH1.3.1 BLDG 38, 64, 82 - LV 3 - ZONES 3, 5, 9 - MECHANICAL PLANS

MH1.4 FOURTH FLOOR - ZONES - MECHANICAL

MH1.4.1 BLDG 64 - LV 4 - ZONE 2 - MECHANICAL PLANS

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-701 MECHANICAL CONTROLS

M-801 MECHANICAL SCHEDULES

E-001 ELECTRICAL LEGENDS & SYMBOLS

E-002 ELECTRICAL GENERAL NOTES

E1.B BASEMENT - ZONES - NEW

E1.B.2 BLDG 64 - LV B - ZONE 2 - NEW

E1.B.3 BLDG 64 - LV B - ZONE 3 - NEW

E1.B.6 BLDG 64 - LV B - ZONE 6 - NEW

E1.B.7 BLDG 19 - LV B - ZONE 7 - NEW

E1.B.9 BLDG 82 - LV B - ZONE 9 - NEW

E1.B.11 BLDG 66 - LV B - ZONE 11 - NEW

E1.B.12 BLDG 62 - LV B - ZONE 12B - NEW

E1.1 FIRST FLOOR LEVEL - ZONES - NEW

E1.1.2 BLDG 64 - LV 1 - ZONE 2 - NEW

E1.1.3 BLDG 64 - LV 1 - ZONE 3 - NEW

E1.1.5 BLDG 38 - LV 1 - ZONE 5 - NEW

E1.1.6 BLDG 64 - LV 1 - ZONE 6 - NEW

E1.1.7 BLDG 19 - LV 1 - ZONE 7 - NEW

E1.1.9 BLDG 82 - LV 1 - ZONE 9 - NEW

E1.1.12 BLDG 62 - LV 1 - ZONE 12B - NEW

E1.1.14 BLDG 27 & 37 - ZONE 14 - NEW

E1.1.15 BLDG 18, 42, 44 & 92 - ZONE 15 - NEW

E1.2 SECOND FLOOR - ZONES - NEW

E1.2.2 BLDG 64 - LV 2 - ZONE 2 - NEW

E1.2.3 BLDG 64 - LV 2 - ZONE 3 - NEW

E1.2.5 BLDG 38 - LV 2 - ZONE 5 NEW

E1.2.9 BLDG 82 - LV 2 - ZONE 9 - NEW

E1.2.12 BLDG 62 - LV 2 - ZONE 12B - NEW

E1.3 THIRD FLOOR - ZONES - NEW

E1.3.3 BLDG 64 - LV 3 - ZONE 3 - NEW

E1.3.5 BLDG 38 - LV 3 - ZONE 5 - NEW

E1.3.9 BLDG 82 - LV 3 -ZONE 9 - NEW

E1.4 FOURTH FLOOR - ZONES - NEW

E1.4.3 BLDG 64A - LV 4 - ZONE 3 - NEW

E-400 DATA CENTER

E-401 ENLARGED ROOM PLANS

E-402 ENLARGED ROOM PLANS

DRAWING INDEX

E-403 ENLARGED ROOM PLANS

E-404 ENLARGED ROOM PLANS

E-405 ENLARGED ROOM PLANS

E-406 ENLARGED ROOM PLANS

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-601 ELECTRICAL DIAGRAMS

E-602 ELECTRICAL DIAGRAMS

E-603 ELECTRICAL DIAGRAMS

E-604 ELECTRICAL DIAGRAMS

E-605 ELECTRICAL DIAGRAMS

E-606 ELECTRICAL DIAGRAMS

E-607 ELECTRICAL DIAGRAMS

E-608 ELECTRICAL DIAGRAMS

E-801 ELECTRICAL SCHEDULES

E-802 ELECTRICAL SCHEDULES

E-803 ELECTRICAL SCHEDULES

E-804 ELECTRICAL SCHEDULES

E-805 ELECTRICAL SCHEDULES

E-806 ELECTRICAL SCHEDULES

E-807 ELECTRICAL SCHEDULES

E-808 ELECTRICAL SCHEDULES

E-809 ELECTRICAL SCHEDULES

E-810 ELECTRICAL SCHEDULES

G004 COVER SHEET - VOLUME 02

G005 DRAWING INDEX

T-001 TECHNOLOGY LEGEND, ABBREV & GENERAL NOTES

T-002 PHASING NOTES

TN100 TECHNOLOGY SITE PLAN

TN101 TECHNOLOGY SITE PLAN

TN1.B LOWER LEVEL - ZONES - NEW

TN1.B.1 BLDG 64 - LV B -ZONE 1 - NEW

TN1.B.2 BLDG 64 - LV B - ZONE 2 - NEW

TN1.B.3 BLDG 64 - LV B - ZONE 3 - NEW

TN1.B.4 BLDG 64 - LV B - ZONE 4 - NEW

TN1.B.5 BLDG 38 - LV B - ZONE 5 - NEW

TN1.B.6 BLDG 64 - LV B - ZONE 6 - NEW

TN1.B.7 BLDG 19 - LV B - ZONE 7 - NEW

TN1.B.8 BLDG 82-4 LV B-01 - ZONE 8 - NEW

TN1.B.9 BLDG 82 - LV B - ZONE 9 - NEW

TN1.B.10 BLDG 64 - LV B - ZONE 10 - NEW

TN1.B.11 BLDG 06 - LV B - ZONE 11 - NEW

TN1.B.12 BLDG 62 - LV B - ZONE 12 - NEW

TN1.B.13 BLDG 74 - LV 1 - ZONE 13 - NEW

TN1.BD BASEMENT - DIAMOND COVERAGE

TN1.1 FIRST FLOOR LEVEL - ZONES - NEW

TN1.1.1 BLDG 64 - LV 1 - ZONE 1 - NEW

TN1.1.2 BLDG 64 - LV 1 - ZONE 2 - NEW

TN1.1.3 BLDG 64 - LV 1 - ZONE 3 - NEW

TN1.1.4 BLDG 64 - LV 1 - ZONE 4 - NEW

TN1.1.5 BLDG 38 - LV 1 - ZONE 5 - NEW

TN1.1.6 BLDG 64 - LV 1 - ZONE 6 - NEW

TN1.1.7 BLDG 19 - LV 1 - ZONE 7 - NEW

TN1.1.8 BLDG 82 - LV 1 - ZONE 8 - NEW

TN1.1.9 BLDG 82 - LV 1 - ZONE 9 - NEW

TN1.1.10 BLDG 64D & 67 - LV 1 - ZONE 10 - NEW

TN1.1.11 BLDG 06 - LV 1 - ZONE 11 - NEW

TN1.1.12 BLDG 62 - LV 1 - ZONE 12 - NEW

TN1.1.13 BLDG 74 - LV 1 - ZONE 13 - NEW

TN1.1.14 BLDG 27 & 37 - ZONE 14 - NEW

TN1.1.14D BLDG 27 & 37 - ZONE 14 - DIAMOND COVERAGE

TN1.1.15 BLDG 18, 42, 44 & 92 - ZONE 15 - NEW

TN1.1.15D BLDG 18, 42, 44 & 92 - ZONE 15 - DIAMOND COVERAGE

TN1.1D FIRST FLOOR - DIAMOND COVERAGE

TN1.2 SECOND FLOOR - ZONES - NEW

TN1.2.1 BLDG 64 - LV 2 - ZONE 1 - NEW

TN1.2.2 BLDG 64 - LV 2 - ZONE 2 - NEW

TN1.2.3 BLDG 64 - LV 2 - ZONE 3 - NEW

TN1.2.4 BLDG 64 - LV 2 - ZONE 4 - NEW

TN1.2.5 BLDG 38 - LV 2 - ZONE 5 NEW

TN1.2.8 BLDG 82 - LV 2 - ZONE 8 - NEW

TN1.2.9 BLDG 82 - LV 2 - ZONE 9 - NEW

TN1.2.12 BLDG 62 - LV 2 - ZONE 12 - NEW

TN1.2D SECOND FLOOR - DIAMOND COVERAGE

TN1.3 THIRD FLOOR - ZONES - NEW

TN1.3.2 BLDG 64 - LV 3 - ZONE 2 - NEW

TN1.3.3 BLDG 64 - LV 3 - ZONE 3 - NEW

TN1.3.4 BLDG 64 - LV 3 - ZONE 4 - NEW

TN1.3.5 BLDG 38 - LV 3 - ZONE 5 - NEW

TN1.3.8 BLDG 82 - LV 3 -ZONE 8 - NEW

TN1.3.9 BLDG 82 - LV 3 -ZONE 9 - NEW

TN1.3D THIRD FLOOR - DIAMOND COVERAGE

TN1.4 FOURTH FLOOR - ZONES - NEW

TN1.4.2 BLDG 64 - LV 4 - ZONE 2 - NEW

TN1.4.3 BLDG 64A - LV 4 - ZONE 3 - NEW

TN1.4.4 BLDG 64 - LV 4 - ZONE 4 - NEW

TN1.4D FOURTH FLOOR - DIAMOND COVERAGE

TD401 ENLARGED DEMOLITION PLANS

TD401A ENLARGED DEMOLITION PLAN PHOTOS

TD402 ENLARGED DEMOLITION PLANS

TD402A ENLARGED DEMOLITION PLAN PHOTOS

TD403 ENLARGED DEMOLITION PLANS

TD403A ENLARGED DEMOLITION PLAN PHOTOS

TD404 ENLARGED DEMOLITION PLANS

TD404A ENLARGED DEMOLITION PLAN PHOTOS

T-300 DATA CENTER CONSTRUCTION PHASING

T-400 DATA CENTER

T-401 ENLARGED ROOM PLANS

T-402 ENLARGED ROOM PLANS

T-403 ENLARGED ROOM PLANS

T-404 ENLARGED ROOM PLANS

T-405 ENLARGED ROOM PLANS

T-406 ENLARGED ROOM PLANS

T-407 ENLARGED ROOM PLANS

T-500 TECHNOLOGY - SCHEDULES

T-501 TECHNOLOGY - TYPICAL RACK ELEVATIONS

T-502 TECHNOLOGY - TYPICAL DATA CENTER RACK ELEVATIONS

T-503 TECHNOLOGY - DETAILS

T-504 TECHNOLOGY - DETAILS

T-601 TECHNOLOGY DIAGRAMS

TELEPHONE BACKBOARD (WALL MOUNTED)

OUTLET DATA ONLY - (1) CAT6A CABLE PER PORT.

# = NUMBER OF PORTS, CH = COUNTER HEIGHT

WORK AREA OUTLET, COMBINATION TELEPHONE/DATA COMMUNICATION

OUTLET -NUMBER OF OUTLETS AS INDICATED ON PLAN.

TTB

COMMUNICATION SYMBOLS

CH = COUNTER HEIGHT

W = WALL MOUNTED TELEPHONE OUTLET AT 48" AFF

#D = QUANTITY OF DATA OUTLETS - (1) CAT6A CABLE

#V = QUANTITY OF ANALOG PHONE OUTLETS - NOT IN CONTRACT

CH

PULL SCHEDULE REQUIREMENTS

CONTRACTOR SHALL PROVIDE PULL SCHEDULE WITH TELECOM SHOP DRAWINGS. TELECOM SHOP DRAWINGS WILL NOT BE REVIEWED

UNLESS THEY INCLUDE PULL SCHEDULES.

CAT6A COPPER CABLE COLOR CODING

WHITE

YELLOW

GREEN/GREY

VIOLET

BLUE

RED

BLACK

- VOICE

- WIFI (MEDICAL/GUEST/VA)

- DATA

- VIDEO SURVEILLANCE

- NURSE CALL

- FIRE ALARM

- BAS & DAS

SYMBOL DESCRIPTION

CEILING MOUNTED WIRELESS ACCESS POINT (WAP) - (2) CAT6A CABLES

PROXIMITY CARD READER, MTD. 4'-0" AFF UNLESS OTHERWISE NOTED.CR

NUMERIC KEYPAD, MTD. 4'-0" AFF UNLESS OTHERWISE NOTED.KP

REQUEST TO EXIT DEVICE IN DOOR HARDWARE. RE

SECURITY ACCESS, VIDEO CAMERA WITH LENS

### - CAMERA ID, REFER TO CAMERA SCHEDULE FOR

MOUNTING AND CAMERA REQUIERMENTS

EX - EXISTING CAMERA

REQUEST TO EXIT DEVICE MOUNTED ABOVE DOOR.RE

TELECOMM GROUND BUS BAR, COPPER

COMBINATION CARD READER/NUMERIC KEYPAD, MTD. 4'-0" AFF

UNLESS OTHERWISE NOTED.

CP

4-POST NETWORK EQUIPMENT RACK.

CABLE TRAY; TYPE, SIZE AND MOUNTING HEIGHT AS INDICATED ON PLANS.

VERTICAL CABLE MANAGEMENT.

TELECOMMUNICATIONS ABBREVIATIONS

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED CABLE

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

AMB OR A AMBIENT

ARCH ARCHITECT

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BAT BATTERY

BBC BONDING BACKBONE CONDUCTOR

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BLDG BUILDING

BPIP BOILER PLANT INSTRUMENTATION PANEL

BYP BY PASS

C CONDUIT

CAB CABINET

CALC CALCULATE

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

SSTV CLOSED CIRCUIT TELEVISION

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

COMPT COMPARTMENT

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

CUR CURRENT

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISTR DISTRIBUTION

DN DOWN

DRSW DOOR SWITCH

DWG DRAWING

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

ESMT EASEMENT

EXIST EXISTING

FLEX FLEXIBLE METALLIC CONDUIT

FOUTT TELEPHONE FLOOR OUTLET

FP FIRE PROTECTION

FT FEET OR FOOT

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GTB GROUND TERMINAL BOX

HT HEIGHT

HZ HERTZ

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

J-BOX JUNCTION BOX

LF LINEAR FEET (FOOT)

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MECH MECHANICAL

MH MANHOLE

MIN MINIMUM

MT MOUNT

MTD MOUNTED

MTG MOUNTING

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEUT OR N NEUTRAL

NIC NOT IN CONTRACT

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR PUSHBUTTON

PBB PRIMARY BONDING BUSBAR

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

RCP REFLECTED CEILING PLAN

REC RECESSED

RECPT RECEPTACLE

RGS RIGID GALVANIZED STEEL

RM ROOM

REQD REQUIRED

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SURF SURFACE

SW SWITCH

TBC TELECOMMUNICATIONS BONDING BUSBAR

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TR TELECOMMUNICATIONS ROOM

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

MSB MAIN SWITCH BOARD

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

WAO WORK AREA OUTLET

WP WEATHERPROOF

STRUCTURED CABLING SYSTEM (SCS):

THE SCS CONTRACTOR (SCSC) SHALL PROVIDE ALL BACKBONE AND HORIZONTAL CABLING, COMPONENTS AND TERMINATIONS AS REQUIRED FOR A COMPLETE AND OPERATIONAL CABLING SYSTEM PER INDUSTRY BEST PRACTICES AS PRESCRIBED BY BICSI AND NEC.

THE SCSC SHALL BE RESPONSIBLE FOR COORDINATION WITH THE ELECTRICAL CONTRACTOR (EC) FOR SPECIFIC LOCATIONS OF ALL TELECOMMUNICATIONS SYSTEM DEVICES, INCLUDING ANCILLARY SYSTEM COMPONENTS AND ASSOCIATED CONDUITS PROVIDED BY THE

EC.

THE ELECTRICAL CONTRACTOR (EC) SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL ROUGH-IN COMPONENTS ASSOCIATED WITH THE TELECOMMUNICATIONS SYSTEM COMPONENTS AS NOTED ON THE DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO, CONDUIT AND BACK-BOXES. THE EC SHALL COORDINATE ALL REQUIREMENTS WITH THE SCS CONTRACTOR.

TELECOM ROOM (TR) EQUIPMENT RACKS:

THE SCS CONTRACTOR (SCS) SHALL FURNISH AND INSTALL ALL EQUIPMENT RACKS. THE SCS CONTRACTOR SHALL FURNISH AND INSTALL ALL CABLING PATCH PANELS (COPPER AND FIBER) WITH RACK, AND SHALL BE RESPONSIBLE FOR ALL CABLE TERMINATIONS AT THE

PATCH PANELS.

THE VA OIT SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL ACTIVE EQUIPMENT, CONTROLLERS, SWITCHES, ETC. THAT

RESIDE WITHIN THESE RACKS.

ACCESS CONTROL:

THE SCS CONTRACTOR (SCS) SHALL BE RESPONSIBLE FOR INSTALLING ALL CABLING AND DEVICES TO SUPPORT THE VA PROVIDED SECURITY HEAD END EQUIPMENT. VA SHALL INSTALL, CONNECT AND CONFIGURE FINAL SECURITY HEAD END EQUIPMENT.

THE ELECTRICAL CONTRACTOR (EC) SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL ROUGH-IN COMPONENTS ASSOCIATED WITH THE SECURITY SYSTEM AS NOTED ON THE DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO, CONDUIT AND BACK-

BOXES. THE EC SHALL COORDINATE WITH THE SCS CONTRACTORS.

GROUNDING AND BONDING:

THE EC SHALL BE RESPONSIBLE FOR PROVIDINGR THE GROUNDING BUSBAR(S) AS ILLUSTRATED ON THE DRAWINGS AND SPECIFICATIONS, AND CONNECTING IT TO THE BUILDING MAIN ELECTRICAL SERVICE GROUND. THE EC SHALL BE RESPONSIBLE FOR

GROUNDING ALL BACKBONE CONDUIT AND CABLE TRAY.

THE SCSC SHALL BE RESPONSIBLE FOR GROUNDING ALL RACKS, CABINETS, ENCLOSURES, PROTECTOR BLOCKS AND CABLE LADDER-

RACK INSIDE TELECOMMUNICATIONS ROOMS.

FIRESTOPPING:

THE EC SHALL BE RESPONSIBLE FOR FIRE-STOPPING SLEEVE ASSEMBLIES TO OBTAIN A UL RATING.

THE SCSC SHALL BE RESPONSIBLE FOR FIRE-STOPPING INSIDE THE SLEEVES AFTER CABLE INSTALLATION IS COMPLETE.

CASEWORK / ,MILLWORK:

THE SCSC SHALL BE RESPONSIBLE FOR INSTALLING TELECOMMUNICATIONS OUTLETS IN CASEWORK, AS REQUIRED. CABLES SHALL BE

CONCEALED IN CASEWORK.

THE EC SHALL BE RESPONSIBLE FOR INSTALLING ASSOCIATED CONDUIT AND BACK-BOXES AND SHALL STUB CONDUIT TO THE ABOVE

ACCESSIBLE CEILING SPACE.

CONDUIT:

THE EC SHALL BE RESPONSIBLE TO PROVIDE AND INSTALL ALL BACKBONE AND HORIZONTAL CABLING PATHWAYS. THIS SHALL INCLUDE ALL INTERIOR CONDUITS, PATHWAY COMPONENTS SUCH AS JUNCTION BOXES, PULL BOXES, WALL/CEILING PENETRATIONS AND CONDUIT SLEEVES, WHETHER SHOWN ON THE DRAWINGS OR AS REQUIRED TO PENETRATE FULL-HEIGHT PARTITIONS AS SHOWN ON THE DRAWINGS. THE EC SHALL PROVIDE AND INSTALL ALL BUSHINGS ON TELECOMMUNICATIONS CONDUITS PRIOR TO INSTALLATION OF

CABLING.

THE SCSC SHALL BE RESPONSIBLE FOR ALL WIRE RACEWAYS, CABLE RUNWAY (LADDER RACK) AND OTHER REQUIREMENTS FOR ROUTING AND SECURING CABLE INSIDE THE MAIN TELECOMMUNICATIONS ROOM (MTR) AND ALL TR'S.

TELECOMMUNICATIONS COMMUNICATIONS OUTLETS (C.O.'S) AND DEVICES:

THE EC SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL CONDUIT AND BACK-BOXES ASSOCIATED WITH THE

TELECOMMUNICATIONS C.O.'S AND DEVICES.

THE SCSC SHALL BE RESPONSIBLE FOR INSTALLATION OF ALL STRUCTURED CABLING, JACKS, FACEPLATES AND JUMPER/PATCH CORDS.

BACKBOARDS:

THE EC SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL BACKBOARDS AS ILLUSTRATED ON THE DRAWINGS AND AS REQUIRED FOR A COMPLETE SYSTEM AS ILLUSTRATED IN THE SPECIFICATIONS. THE EC SHALL BE RESPONSIBLE FOR ROUGH-IN OF ALL

CONDUIT AND BACK-BOXES. POWER CONDUITS SHALL BE CONCEALED BEHIND ALL BACKBOARDS.

#D #V

FLOOR RECEPTACLE, COMBINATION TELEPHONE/DATA COMMUNICATION OUTLET -

NUMBER OF OUTLETS AS INDICATED ON PLAN.

#D #V

#D = QUANTITY OF DATA OUTLETS - (1) CAT6A CABLE

#V = QUANTITY OF ANALOG PHONE OUTLETS - NOT IN CONTRACT

CONDUIT SIZE

(ID)

MAX NUMBER OF FIBER OPTIC CABLES

PER CONDUIT

CONDUIT FILL

1.00"

1.25"

1.50"

2.00"

2.50"

3.00"

4.00"

53%

40%

40%

40%

40%

CONDUIT: 24-STRAND

ARMORED OS2 FIBER OPTIC

CABLE FILL CHART

PRECAST CONCRETE, TRAFFIC RATED HANDHOLE. SIZE AS INDICATED ON PLANSHH

MAGNETIC DOOR CONTACT, MTD. IN TOP OF DOOR FRAME.DC

CEILING MOUNTED, DUAL TECHNOLOGY MOTION SENSOR FOR

INTRUSION DETECTION SYSTEM.

WALL MOUNTED AT 7' AFF, DUAL TECHNOLOGY MOTION

SENSOR FOR INTRUSION DETECTION SYSTEM.

CONDUIT SIZE

(ID)

MAX NUMBER OF CAT6A CABLES PER

CONDUIT

CONDUIT FILL

1.10"

1.25"

1.50"

2.00"

2.50"

3.00"

4.00"

34.7%

39.7%

38.8%

38.0%

38.9%

39.7%

39.9%

CONDUIT: CAT6A

CABLE FILL CHART

BASIS OF DESIGN CAT6A CABLE NOMINAL OUTTER DIAMETER IS 0.35".

CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING CABLE FILL FOR CABLES

WITH LARGER OR SMALLER NOMINAL OUTTER DIAMETER.

BASIS OF DESIGN OS2 24-STRAND ARMORED FIBER OPTIC CABLE NOMINAL OUTTER

DIAMETER IS 0.77". CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING CABLE

FILL FOR CABLES WITH LARGER OR SMALLER NOMINAL OUTTER DIAMETER.

COORDINATION NOTES:

CONDUIT SIZE

(ID)

MAX NUMBER OF FIBER OPTIC CABLES

PER CONDUIT

CONDUIT FILL

1.00"

1.25"

1.50"

2.00"

2.50"

3.00"

4.00"

53%

31%

40%

40%

40%

40%

40%

CONDUIT: 12-STRAND

ARMORED OS2 FIBER OPTIC

CABLE FILL CHART

BASIS OF DESIGN OS2 12-STRAND ARMORED FIBER OPTIC CABLE NOMINAL OUTTER

DIAMETER IS 0.53". CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING CABLE

FILL FOR CABLES WITH LARGER OR SMALLER NOMINAL OUTTER DIAMETER.

CONDUIT SIZE

(ID)

MAX NUMBER OF FIBER OPTIC CABLES

PER CONDUIT

CONDUIT FILL

1.00"

1.25"

1.50"

2.00"

2.50"

3.00"

4.00"

53%

31%

40%

40%

40%

40%

CONDUIT: 24-STRAND

ARMORED OM4 FIBER OPTIC

CABLE FILL CHART

BASIS OF DESIGN OM4 24-STRAND ARMORED FIBER OPTIC CABLE NOMINAL OUTTER

DIAMETER IS 0.644". CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING CABLE

FILL FOR CABLES WITH LARGER OR SMALLER NOMINAL OUTTER DIAMETER.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:4

A

M

T-001

TECHNOLOGY LEGEND, ABBREV &

GENERAL NOTES

LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS CVM

100% CONSTRUCTION

DOCUMENTS

CHRISTOPHER VAN METER

RCDD Reg. No. 285002

SHEET LIST

SHEET NUMBER SHEET NAME

T-001 TECHNOLOGY LEGEND, ABBREV & GENERAL NOTES

T-002 PHASING NOTES

TN100 TECHNOLOGY SITE PLAN

TN101 TECHNOLOGY SITE PLAN

TN1.B LOWER LEVEL - ZONES - NEW

TN1.B.1 BLDG 64 - LV B -ZONE 1 - NEW

TN1.B.2 BLDG 64 - LV B - ZONE 2 - NEW

TN1.B.3 BLDG 64 - LV B - ZONE 3 - NEW

TN1.B.4 BLDG 64 - LV B - ZONE 4 - NEW

TN1.B.5 BLDG 38 - LV B - ZONE 5 - NEW

TN1.B.6 BLDG 64 - LV B - ZONE 6 - NEW

TN1.B.7 BLDG 19 - LV B - ZONE 7 - NEW

TN1.B.8 BLDG 82-4 LV B-01 - ZONE 8 - NEW

TN1.B.9 BLDG 82 - LV B - ZONE 9 - NEW

TN1.B.10 BLDG 64 - LV B - ZONE 10 - NEW

TN1.B.11 BLDG 06 - LV B - ZONE 11 - NEW

TN1.B.12 BLDG 62 - LV B - ZONE 12 - NEW

TN1.B.13 BLDG 74 - LV 1 - ZONE 13 - NEW

TN1.BD BASEMENT - DIAMOND COVERAGE

TN1.1 FIRST FLOOR LEVEL - ZONES - NEW

TN1.1.1 BLDG 64 - LV 1 - ZONE 1 - NEW

TN1.1.2 BLDG 64 - LV 1 - ZONE 2 - NEW

TN1.1.3 BLDG 64 - LV 1 - ZONE 3 - NEW

TN1.1.4 BLDG 64 - LV 1 - ZONE 4 - NEW

TN1.1.5 BLDG 38 - LV 1 - ZONE 5 - NEW

TN1.1.6 BLDG 64 - LV 1 - ZONE 6 - NEW

TN1.1.7 BLDG 19 - LV 1 - ZONE 7 - NEW

TN1.1.8 BLDG 82 - LV 1 - ZONE 8 - NEW

TN1.1.9 BLDG 82 - LV 1 - ZONE 9 - NEW

TN1.1.10 BLDG 64D & 67 - LV 1 - ZONE 10 - NEW

TN1.1.11 BLDG 06 - LV 1 - ZONE 11 - NEW

TN1.1.12 BLDG 62 - LV 1 - ZONE 12 - NEW

TN1.1.13 BLDG 74 - LV 1 - ZONE 13 - NEW

TN1.1.14 BLDG 27 & 37 - ZONE 14 - NEW

TN1.1.14D BLDG 27 & 37 - ZONE 14 - DIAMOND COVERAGE

TN1.1.15 BLDG 18, 42, 44 & 92 - ZONE 15 - NEW

TN1.1.15D BLDG 18, 42, 44 & 92 - ZONE 15 - DIAMOND COVERAGE

TN1.1D FIRST FLOOR - DIAMOND COVERAGE

TN1.2 SECOND FLOOR - ZONES - NEW

TN1.2.1 BLDG 64 - LV 2 - ZONE 1 - NEW

TN1.2.2 BLDG 64 - LV 2 - ZONE 2 - NEW

TN1.2.3 BLDG 64 - LV 2 - ZONE 3 - NEW

TN1.2.4 BLDG 64 - LV 2 - ZONE 4 - NEW

TN1.2.5 BLDG 38 - LV 2 - ZONE 5 NEW

TN1.2.8 BLDG 82 - LV 2 - ZONE 8 - NEW

TN1.2.9 BLDG 82 - LV 2 - ZONE 9 - NEW

TN1.2.12 BLDG 62 - LV 2 - ZONE 12 - NEW

TN1.2D SECOND FLOOR - DIAMOND COVERAGE

TN1.3 THIRD FLOOR - ZONES - NEW

TN1.3.2 BLDG 64 - LV 3 - ZONE 2 - NEW

TN1.3.3 BLDG 64 - LV 3 - ZONE 3 - NEW

TN1.3.4 BLDG 64 - LV 3 - ZONE 4 - NEW

TN1.3.5 BLDG 38 - LV 3 - ZONE 5 - NEW

TN1.3.8 BLDG 82 - LV 3 -ZONE 8 - NEW

TN1.3.9 BLDG 82 - LV 3 -ZONE 9 - NEW

TN1.3D THIRD FLOOR - DIAMOND COVERAGE

TN1.4 FOURTH FLOOR - ZONES - NEW

TN1.4.2 BLDG 64 - LV 4 - ZONE 2 - NEW

TN1.4.3 BLDG 64A - LV 4 - ZONE 3 - NEW

TN1.4.4 BLDG 64 - LV 4 - ZONE 4 - NEW

TN1.4D FOURTH FLOOR - DIAMOND COVERAGE

TD401 ENLARGED DEMOLITION PLANS

TD401A ENLARGED DEMOLITION PLAN PHOTOS

TD402 ENLARGED DEMOLITION PLANS

TD402A ENLARGED DEMOLITION PLAN PHOTOS

TD403 ENLARGED DEMOLITION PLANS

TD403A ENLARGED DEMOLITION PLAN PHOTOS

TD404 ENLARGED DEMOLITION PLANS

TD404A ENLARGED DEMOLITION PLAN PHOTOS

T-300 DATA CENTER CONSTRUCTION PHASING

T-400 DATA CENTER

T-401 ENLARGED ROOM PLANS

T-402 ENLARGED ROOM PLANS

T-403 ENLARGED ROOM PLANS

T-404 ENLARGED ROOM PLANS

T-405 ENLARGED ROOM PLANS

T-406 ENLARGED ROOM PLANS

T-407 ENLARGED ROOM PLANS

T-500 TECHNOLOGY - SCHEDULES

T-501 TECHNOLOGY - TYPICAL RACK ELEVATIONS

T-502 TECHNOLOGY - TYPICAL DATA CENTER RACK ELEVATIONS

T-503 TECHNOLOGY - DETAILS

T-504 TECHNOLOGY - DETAILS

T-601 TECHNOLOGY DIAGRAMS

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

1. CONTRACTOR MUST COORDINATE WITH VA OIT PRIOR TO ALL PLANNED NETWORK OUTAGES AND MAKE ALL EFFORTS TO MINIMIZE DURATION OF ANY

PLANNED OR UN PLANNED NETWORK OUTAGE.

2. PRODUCTS SHALL BE OF MATERIALS THAT ARE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED.

3. WORKING CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 110, COORDINATE EQUIPMENT INSTALLATION TO MAINTAIN REQUIRED CLEARANCES.

4. IF AN OUTLET BOX IS REQUIRED TO BE LOCATED IN AN ASSEMBLY OR PARTITION RATED AS "FIRE/SMOKE" OR "SMOKE" OR IDENTIFIED AS EITHER

"FIRE/SMOKE" OR "SMOKE", THEN ALL OF THE FOLLOWING CONDITIONS SHALL BE MET:

A. THE OUTLET BOX SHALL BE METALLIC.

B. THE OUTLET BOX OPENINGS SHALL OCCUR ONLY ON ONE SIDE OF THE FRAMING SPACE.

C. THE OUTLET BOX OPENINGS SHALL NOT EXCEED 16 SQUARE INCHES.

D. ALL CLEARANCES BETWEEN THE OUTLET BOX AND THE WALL BOARD MATERIAL SHALL BE COMPLETELY SEALED WITH APPROVED MATERIALS IN

ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS FOR THE PROJECT.

E. PROVIDE A SUPPLEMENTAL BARRIER AROUND OUTLETS LARGER THAN 16 INCHES SO THAT THE ORIGINAL RATING OF THE PENETRATION IS

MAINTAINED.

F. THE TOTAL AGGREGATE SURFACE AREA OF THE OUTLET BOX SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET.

G. THE OUTLET BOX SHALL BE SEPARATED FROM OPENINGS ON THE OPPOSITE SIDE OF THE RATED PARTITION BY A MINIMUM HORIZONTAL DISTANCE

OF 24 INCHES.

H. THE OUTLET BOX SHALL BE SECURELY FASTENED TO A PARTITION FRAMING MEMBER BY MEANS OF AN APPROVED ATTACHMENT METHOD.

I. OPENINGS CUT INTO THE WALL BOARD MATERIAL SHALL NOT EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE

OPENING.

5. LOCATIONS OF EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE, COORDINATE EXACT EQUIPMENT LOCATION AND CONNECTION

REQUIREMENTS WITH THE APPROPRIATE TRADE PRIOR TO INSTALLATION.

6. EXACT OUTLET LOCATIONS AND EXACT QUANTITIES ARE APPROXIMATE AND ARE BASED ON LIMITED SITE INVESTIGATIONS. CONTRACTOR SHALL

DOCUMENT QUANTITY AND LOCATION VARIANCES ON AS-BUILT DRAWINGS.

7. FOR EXACT LOCATION OF CEILING MOUNTED EQUIPMENT REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN. LOCATIONS OF EQUIPMENT NOT INCLUDED ON THE REFLECTED CEILING PLAN SHALL BE COORDINATED WITH THOSE ITEMS SHOWN. COORDINATION OF CEILING MOUNTED EQUIPMENT

SHALL BE PRIOR TO ANY ROUGH-IN. NOTIFY ARCHITECT OF ANY DISCREPANCY.

8. NOT ALL EXISTING EQUIPMENT IS INDICATED ON CONSTRUCTION DOCUMENTS FOR CLARITY. CONTRACTOR TO FIELD VERIFY ALL NETWORK DATA DEVICES AND ASSOCIATED RACEWAYS AS REQUIRED. EXISTING RACEWAYS, FOUND TO BE IN SERVICEABLE CONDITION, MAY BE REUSED AS APPLICABLE. CONTRACTOR SHALL REMOVE ABANDONED RACEWAYS THAT ARE NOT REUSED, UNLESS SPECIFICALLY NOTED OTHERWISE.

9. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING EQUIPMENT, NOT ASSOCIATED WITH THIS CONTRACT, THAT IS LOCATED IN AREAS OF WORK. ANY DAMAGE TO EXISTING SYSTEMS, EQUIPMENT, CABLING, MATERIALS OR FINISHES MUST BE REPAIRED OR REPLACED AT CONTRACTORS EXPENSE. REPAIRS AND REPLACEMENT MUST BE APPROVED AND ACCEPTED BY THE VA.

10. PROVIDE FINAL CONNECTIONS TO OWNER PROVIDED EQUIPMENT WHERE INDICATED ON THE PLAN DRAWINGS.

11. PRIOR TO ROUGH-IN AND INSTALLATION OF ANY FLOOR MOUNTED DEVICE, VERIFY LOCATION WITH THE ARCHITECT.

12. VERIFY AND COORDINATE THE LOCATION OF REQUIRED DIVISION 27 OUTLETS WITH OTHER TRADE DRAWINGS AND OWNER PROVIDED EQUIPMENT.

13. ALL RACEWAY SYSTEMS SHOWN TO SUPPORT THE INSTALLATION OF THE DIVISION 27 EQUIPMENT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. PROVIDE COORDINATION FOR THE INSTALLATION OF THIS RACEWAY SYSTEM WITH THE ELECTRICAL CONTRACTOR.

14. ALL BONDING AND GROUNDING ELEMENTS UTILIZED FOR STRUCTURED CABLING SYSTEM SHALL BE IN COMPLIANCE WITH SPECIFICATION SECTION 270526.

15. CABLE INSTALLED BELOW SLAB SHALL HAVE INDOOR/OUTDOOR RATED JACKET FOR PROTECTION OF STRUCTURED CABLE.

16. TELECOMMUNICATIONS ROOM SHALL BE BONDED AND GROUNDED IN ACCORDANCE WITH TIA-607D.

17. ALL TELECOMMUNICATIONS CONDUITS SHALL BE PROVIDED WITH BUSHINGS AT EACH END FOR PROTECTION OF STRUCTURED CABLE.

18. CAT6A CABLE BUNDLE SIZES AND CABLES ENCLOSED IN CONDUITS SHALL NOT EXCEED CABLE QUANTITIES INDICATED IN NEC TABLE 725.144, UNLESS CABLES ARE UL LISTED AS X-LP (0.5A). TYPE 4 POE CABLES WITHOUT LP CERTIFICATION ARE SUBJECT TO INSPECTION TO ENSURE BUNDLE SIZE AND

CURRENT LIMITATIONS PER NEC TABLE 725.144 ARE NOT EXCEEDED.

19. PROVIDE FACTORY PRE-TERMINATED CAT6A AND FIBER OPTIC CABLES WHEN DISTANCES ARE KNOWN. FIELD TERMINATED CABLES ARE ALLOWED IF

KNOWN DISTANCES ARE NOT ABLE TO BE DETERMINED.

20. BUNDLE CABLES TOGETHER IN GROUPS OF RELEVANCE (FOR EXAMPLE, CABLES TO A SINGLE EQUIPMENT DISTRIBUTOR OR UPLINKS TO CORE

DEVICES), AS THIS WILL EASE MANAGEMENT AND TROUBLESHOOTING.

21. BUNDLES OF CABLES, WHEN NECESSARY, SHOULD BE BUILT FROM SUB-BUNDLES OF NO MORE THAN 6-8 INDIVIDUAL CABLES. THE LARGER BUNDLES

SHOULD NOT EXCEED FOUR SUB-BUNDLES OF LIKE QUANTITY.

22. WHEN BUNDLING OR SECURING CABLES, USE VELCRO-BASED TIES NOT MORE THAN EVERY 3 FT TO 6 FT, AND MORE FREQUENTLY AS NEEDED TO MAINTAIN A CLEAN INSTALLATION. DO NOT USE ZIP TIES OR TWIST TIES FOR CABLE BUNDLING OR SECURING, AS THESE APPLY PRESSURE AT

CONCENTRATED LOCATIONS ON THE CABLES AND WILL CAUSE DAMAGE.

23. ONLY BUNDLE LIKE CABLE TYPES. DO NOT BUNDLE FIBER, POWER, AND UTP TOGETHER.

24. PROVIDE CONDUITS, SLEEVES, AND J-HOOKS AS REQUIRED FOR COMPLETE INSTALLATION OF HORIZONTAL AND BACKBONE CABLING.

25. PROVIDE UL LISTED FIRE/SMOKE SYSTEMS OR ASSEMBLIES IN AND AROUND ALL RATED BARRIER PENETRATIONS AS REQUIRED BY CODE. REFER TO

ARCHITECTURAL DRAWINGS FOR FIRE AND SMOKE BARRIER RATINGS.

26. CONTRACTOR SHALL REMOVE ALL NETWORK CABLING, WORK AREA OUTLETS, PORTS, JACKS, AND ASSOCIATED PATCH PANELS RATED CAT6 AND BELOW (EXCLUDING ANALOG TELEPHONE OUTLETS AND CABLING) AS INDICATED ON PLANS, UNLESS NOTED OTHERWISE.

27. CONTRACTOR SHALL REUSE EXISTING J-HOOKS, CONDUIT AND OTHER EXISTING NETWORK PATHWAYS AS CABLE FILL ALLOWS. NEW HORIZONTAL

CABLE INSTALLATION MUST BE IN AN ORGANIZED AND CONSOLIDATED MANOR.

28. NETWORK OUTLET UPGRADE INCLUDES, BUT NOT LIMITED TO: REMOVAL AND DISPOSAL OF EXISTING NETWORK OUTLET/JACK, FACE PLATE, AND CABLING. PROVIDING ALL REQUIRE MATERIALS, TOOLS, TESTING EQUIPMENT, LABOR AND CONSUMABLES REQUIRED FOR COMPLETE INSTALLATION, LABELING, TESTING AND CERTIFICATION OF COMPLETE CAT6A NETWORK LINK FROM OUTLET TO PATCH PANEL.

29. CONTRACTOR SHALL PROVIDE PULL BOXES AS REQUIRED AND SIZED PER ANSI/TIA 569. MAXIMUM SPACING BETWEEN PULL BOXES SHALL NOT EXCEED 100' FOR STRAIGHT CONDUIT RUNS, AND AT A CUMULATIVE MAXIMUM OF 180 DEGREES OF CONDUIT BEND.

30. NETWORK CABLING SHALL BE SEGREGATED FROM ALL OTHER SYSTEMS CABLING INCLUDING, BUT NOT LIMITED TO: ACCESS CONTROL, SECURITY, SSTV, NURSE CALL AND FIRE ALARM SYSTEMS. WHEN ROUTING NETWORK CABLING IN CONDUIT, NETWORK CABLING SHALL BE ROUTED IN DEDICATED NETWORK CONDUITS. WHEN ROUTED IN CABLE TRAYS, NETWORK CABLING MUST BE BUNDLED WITH NETWORK CABLING ONLY.

31. CONTRACTOR SHALL REPLACE ALL CEILING TILES AT THE END OF EACH SHIFT FOR WORK AREAS OUTSIDE OF A RATED CONSTRUCTION BARRIER. IF TILES CANNOT BE REPLACED, A 1-HOUR FIRE RATED SEPARATION WILL BE REQUIRED BETWEEN THE CONSTRUCTION AREA AND THE OCCUPIED

PORTIONS OF THE BUILDING.

32. CONTRACTOR SHALL PROVIDE TEMPORARY FIRESTOPPING (MINERAL WOOL) AT THE END OF THE WORK SHIFT IF ADDITIONAL CABLING WILL BE PULLED

THROUGH A FIRE RATED PENETRATION AT A LATER WORK SHIFT.

GENERAL PROJECT NOTES

PHASE 1:

1. EXISTING RACK MOUNTED EQUIPMENT TO BE PROTECTED IN PLACE; RACK J7 TO BE SHIFTED TO ACCOMMODATE INSTALLATION OF NEW RACK LAYOUT

AS INDICATED ON PLANS. TEMPORARY PROTECTIVE STRUCTURES TO BE CONSTRUCTED FOR PROTECTION OF EXISTING RACKS AND EQUIPMENT. .

2. DEMOLISH WALLS, CEILING, AND RAISED FLOOR SYSTEM PER ARCHITECTURAL CONSTRUCTION DOCUMENTS.

A. REMOVE OLD RAISED FLOORING AND INSTALL NEW FOR AREAS THAT ARE CLEARED OF EQUIPMENT.

B. DISCONNECT AND REMOVE EXISTING DEVICES NOT SUPPORTING EXISTING RACKS.

3. INSTALL NEW STRUCTURAL SUPPORT ELEMENTS PER CONSTRUCTION DOCUMENTS.

4. NEW FLOOR AND CEILING TO BE INSTALLED.

A. INSTALL ADDITIONAL INSULATION ADDED ABOVE CEILING PER ARCHITECTURAL CONSTRUCTION DOCUMENTS.

B. INSTALL NEW RAISED FLOORING FOR AREAS FREE OF EXISTING EQUIPMENT TO CREATE SPACE FOR NEW EQUIPMENT INSTALLATION.

5. INSTALL DATA CENTER NEW EQUIPMENT.

A. INSTALL NEW ELECTRICAL EQUIPMENT, UPS EQUIPMENT AND ASSOCIATED DEVICES AND ACCESSORIES PER CONSTRUCTION DOCUMENTS.

B. INSTALL NEW MECHANICAL EQUIPMENT PER CONSTRUCTION DOCUMENTS.

a. ONE CRAC UNIT WOULD REMAIN TO BE INSTALLED AFTER THIS PHASE.

C. INSTALL NEW NETWORK AND SERVER CABINETS.

D. INSTALL NEW CABLE TRAY SYSTEM.

6. INSTALL RACK MOUNTED EQUIPMENT. - CORE-A AND CORE-B ARE TO REMAIN OPERATIONAL DURING TRANSITION FROM EXISTING TO NEW RACKS.

A. COORDINATE WITH VA FOR INSTALLATION OF OWNER PROVIDED AND INSTALLED CABINET MOUNTED EQUIPMENT.

B. INSTALL, TERMINATE AND TEST NEW DATA CENTER HDA/MDA CABLING.

C. TRANSITION CORE-A OVER TO NEW CABINETS.

a. BEGIN TRANSITION OF SYSTEMS FROM OLD EQUIPMENT TO NEW DATA CENTER EQUIPMENT WITH NON-CRITICAL SYSTEMS. COORDIANTE WITH

LOCAL VA PERSONNEL PRIOR TO BEGNING TRANSITION.

D. PROVIDE TEMPORARY UMBILICAL CONNECTION BETWEEN NEW CORE-A LOCATION AND EXISTING CORE-B.

E. PROVIDE TEMPORARY FIBER OPTIC AND COPPER PATCH CABLES AS REQUIRED FOR RENOVATION WORK.

F. ACQUIRE APPROVAL FROM VA FOR CABLING AND EQUIPMENT INSTALLATION AND TESTING.

7. COORDINATE TRANSITION OF DEMARC CABLING TO NEW EQUIPMENT WITH VA PRIOR TO TRANSITION. CORE-A IN NEW EQUIPMENT AND CORE-B IN OLD

EQUIPMENT SHALL BOTH BE CONNECTED TO EXISTING DEMARC DURING TRANSITION.

8. CONNECT NEW TR EQUIPMENT TO CORE-A IN NEW DATA CENTER EQUIPMENT WHILE EXISTING TR EQUIPMENT IS CONNECTED TO CORE-B IN OLD DATA

CETNER EQUIPMENT.

PHASE 3:

1. FINALIZATION OF DATA CENTER SPACE.

A. DECOMMISSIONED EXISTING RACKS ARE REMOVED.

B. REMOVE EXISTING UPS SYSTEM AND TURN OVER TO VA.

C. REPLACE REMAINING EXISTING FLOORING SYSTEM WITH NEW FLOORING SYSTEM.

D. REMAINING CRAC IS INSTALLED AND BROUGHT ON-LINE.

SUGGESTED PHASING SEQUENCE OF WORK FOR DATA

CENTER CONSTRUCTION AND DEMOLITION

PHASE 1:

1. CONSTRUCT NEW TR - MAXIMUM OF TRANSITIONING (2) TRS AT THE SAME TIME. VA TO PROVIDE MAXIMUM OF (10) TRANSITIONAL SWITCHES FOR

TRANSITION OF TRS.

A. INSTALL NEW NETWORK RACKS, CABLE TRAY, PLYWOOD, ACCESS CONTROL AND SECURITY DEVICES.

B. INSTALL NEW ELECTRICAL AND MECHANICAL EQUIPMENT AND DEVICES.

C. INSTALL NEW NETWORK AND POWER EQUIPMENT INTO NEW NETWORK RACKS.

D. PROVIDE TEMPORARY FIBER OPTIC PATCH CABLES DURING TRANSITION FROM OLD TR TO NEW TR.

E. CONNECT NEW FIBER OPTIC BACKBONE CABLING FROM NEW CORE-A DATA CENTER EQUIPMENT TO NEW RACK MOUNTED FIBER OPTIC PATCH

EQUIPMENT.

F. PERFORM TESTING OF FIBER OPTIC BACKBONE CABLING AND TERMINATIONS.

G. TERMINATE NEW HORIZONTAL CAT6A CABLING FROM NEW DATA OUTLETS AT NEW PATCH PANELS.

H. TEST HORIZONTAL CAT6A CABLING AND TERMINATIONS.

I. VERIFY ALL EXISTING TCO LOCATIONS, INDICATED ON CONSTRUCTION DOCUMENTS OR DISCOVERED DURING CONSTRUCTION, HAVE BEEN

CONNECTED TO NEW TR EQUIPMENT WITH NEW CAT6A CABLING.

J. UPON COMPETITION OF DATA CENTER RENOVATION CORE-B RELOCATION AND TESTING, CUT-OVER TO CORE-B CONNECTIONS FROM NEW DATA

CENTER EQUIPMENT.

PHASE 3:

1. UPON VERIFICATION THAT ALL OUTLETS ARE FULLY FUNCTIONAL, BEGIN DEMOLITION OF EXISTING TR.

A. REMOVE ALL DECOMMISSIONED HORIZONTAL CABLING FROM DEVICE TO SOURCE.

B. REMOVE DECOMMISSIONED FIBER OPTIC BACKBONE CABLING FROM TR TO SOURCE.

C. IF ALL EQUIPMENT INSTALLED IN EXISTING RACK IS NETWORK EQUIPMENT AND ALL EQUIPMENT HAS BEEN REMOVED, REMOVE RACK AND RETURN

TO VA IT.

D. IF NON-NETWORK EQUIPMENT (WIRELESS NETWORK, PHONE, BDA, ETC.) IS INSTALLED INTO EXISTING RACK, RACK AND EQUIPMENT ARE TO REMAIN

AS INSTALLED.

SUGGESTED PHASING SEQUENCE OF WORK FOR TELECOM

ROOM CONSTRUCTION AND DEMOLITION

PHASE 2:

1. CONTRACTOR TO COORDINATE AREAS OF OUTAGE FOR HORIZONTAL CAT6A CABLING REPLACEMENT WITH VA A MINIMUM OF 14 DAYS PRIOR TO

OUTAGE.

A. CONTRACTOR TO COORDINATE EXTENTS OF AREA OF OUTAGE WITH VA FOR TEMPORARY RELOCATION OF PERSONNEL, OR AFTER-HOURS WORK AS

REQUIRED BY THE VA.

2. BOTH NEW TR AND EXISTING TR WILL NEED TO BE OPERATIONAL FOR REPLACEMENT OF HORIZONTAL CABLING.

A. DEMOLITION OF EXISTING TR EQUIPMENT MAY COMMENCE ONLY AFTER ALL HORIZONTAL CABLING HAS BEEN REPLACED WITH NEW CABLING FROM

NEW TR.

3. CONTRACTOR TO REPLACE EXISTING HORIZONTAL CABLING TO ALL DATA OUTLETS IN PLANNED AREA OF OUTAGE.

A. CONTRACTOR SHALL WALK THE SPACE OF PLANNED OUTAGE TO VERIFY EXACT LOCATION AND QUANTITY OF ALL EXISTING DATA OUTLETS.

CONTRACT DOCUMENTS MAY NOT HAVE CAPTURED ALL EXISTING LOCATIONS DUE TO EXISTING OCCUPIED SPACES AND FURNITURE.

B. REMOVE CABLING FROM DATA OUTLET TO EXISTING PATCH PANEL.

C. INSTALL NEW CABLING FROM NEW TR PATCH PANEL TO NEW DATA OUTLET IN EXISTING LOCATION.

SUGGESTED PHASING SEQUENCE OF WORK FOR

HORIZONTAL CABLING REPLACEMENT

PHASE 1:

• RELOCATE EXISTING DATA CENTER RACKS/CABINETS PER PHASING DRAWINGS FOR RENOVATION OF EXISTING DATA CENTER SPACE AND

INSTALLATION OF NEW HVAC EQUIPMENT.

• CONSTRUCT TEMPORARY BARRIERS PER ARCHITECTURAL CONSTRUCTION DOCUMENTS.

• INSTALL STRUCTURAL REINFORCEMENT MODIFICATIONS TO THE DATA CENTER SPACE.

• INSTALL NEW DATA CENTER EQUIPMENT AND HVAC EQUIPMENT PER CONSTRUCTION DOCUMENTS.

• CONSTRUCT NEW TRS AND INSTALLATION OF NEW TR EQUIPMENT.

• INSTALL NEW REDUNDANT FIBER OPTIC BACKBONES FROM NEW DATA CENTER TO NEW TRS.'

PHASE 2:

• INSTALL NEW HORIZONTAL CABLING PER CONSTRUCTION DOCUMENTS.

PHASE 3:

• REMOVE OLD FIBER OPTIC BACKBONE CABLING, OLD TR EQUIPMENT AND OLD HORIZONTAL CABLING.

OVERALL SUGGESTED PHASING SEQUENCE OF WORK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:4

A

M

T-002

PHASING NOTES LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS CVM

100% CONSTRUCTION

DOCUMENTS

CHRISTOPHER VAN METER

RCDD Reg. No. 285002524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

E

D

IV

IS

IO

N

A V

E

LT PL

LT PL

LT PL

PP

PP

PP

PP

PPANCH ANCHPP

FIBER OPTIC

CABLE

MANHOLE

C O N C

C O N C

C O N C

C O N C

C O N C

CONC

CONC

C O N C

C O N C

TELPED

TELPED

TELPED

TELJB

FH

WM

WV

FH

WV

(N

'4 W

.8

(S

'4

E

1.

N

'5

.0 1'

DECK

TANK

AC

AC

TANKS

SIGN

SIGN

AC

RAMP

O H

PL

OHP

L

O H P L

O H P L

O H P L

O H P L

O H P L

S E

D

IV

IS

IO

N

A V

E

LT PL

LT PL

LT PL

PP

PP

PP

PP

PPANCH ANCHPP

FIBER OPTIC

CABLE

MANHOLE

C O N C

C O N C

C O N C

C O N C

C O N C

CONC

CONC

C O N C

C O N C

TELPED

TELPED

TELPED

TELJB

FH

WM

WV

FH

WV

(N

'4

.8

(S

'4

1.

N

'5

.0 1'

DECK

TANK

AC

AC

TANKS

SIGN

SIGN

AC

RAMP

O H

PL

OHP

L

O H P L

O H P L

O H P L

O H P L

O H P L

REFER TO SHEET

TN1.B.11 FOR

INFORMATION IN

THIS AREA

CT

BUILDING

M

IN

IM

U

M

(3) 4" CONDUITS, (2) SPARE WITH PULL STRING.

CONDUITS ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH PULL

STRING. CONDUITS ROUTED BELOW GRADE.

HH

(3) 4" CONDUITS, (2) SPARE

WITH PULL STRING.

CONDUITS ROUTED IN

CRAWL SPACE

HH

HH

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 2" CONDUITS, (2) SPARE WITH

PULL STRINGS. CONDUITS ROUTED

BELOW GRADE

HH

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE..

1 TYPICAL

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2)

SPARE WITH PULL

STRING. CONDUITS

ROUTED IN CRAWL

SPACE

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE

HH

HH

M

IN

IM

U M

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:0

:1

P

M

TN100

TECHNOLOGY SITE PLAN LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS CVM

100% CONSTRUCTION

DOCUMENTS

CHRISTOPHER VAN METER

RCDD Reg. No. 285002

CODED NOTES:

DRAWING NOTES:

1. UNDERGROUND CONDUIT ROUTING AND HANDHOLE LOCATIONS INDICATED ON THIS PLAN ARE

DIAGRAMATIC. CONTRACTOR TO COORDINATE EXACT CONDUIT ROUTING AND HANDHOLE

PLACEMENT WITH EXISTING FILED CONDITIONS AND CIVIL PLANS PRIOR TO CONSTRUCTION.

MAXIMUM CONDUIT LENGTH BETWEEN HANDHOLES IS NOT TO EXCEED 250' OR CUMULATIVE 180

DEGREES OF CONDUIT BEND. REFER TO DETAIL 10 ON SHEET T-503 FOR ADDITIONAL INFORMATION.

2. REFER TO FIBER BACKBONE RISER DIAGRAM ON SHEET T-601 FOR ADDITIONAL INFORMATION ON

FIBER OPTIC CABLE TYPES AND QUANTITIES.

3. REFER TO CONCRETE ENCASED DUCTBANK DETAIL ON SHEET T-504.

REFER TO DETAIL 1 ON SHEET T-504 AND DETAIL 10 ON SHEET T-503 FOR ADDITIONAL INFORMATION.

COORDINATE EXACT ENTRY POINT INTO BUILDING WITH ARCHITECTURAL AND STRUCTURAL PRIOR TO CONSTRUCTION. FIBER OPTIC CABLE CONDUITS ARE NOT PERMITTED TO BE EXPOSED ABOVE GRADE.

SAW CUT, PATCH AND REPAIR ROADWAY TO MATCH SURROUNDING AREA FOR INSTALLATION OF

DUCTBANK.

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

NN

0 15' 30' 60' 90'

1" = 30'

1" = 30'-0"2

TECHNOLOGY SITE PLAN - NORTH

M

A R

IO

N

A V

E

LT PL

ANCH(2)

PP

FOCJB

C O N C

C O N C

C O N C

C O N C

C O N C

C O N C

C O N C

TELPED

TELPED

F H

FH

N

1°

'3

.4 C (N

1°

' 1

.3

RUIN

STAIRS

AC

AC

AC

AC

PUMPS

STAIRS

TANK

POOL

SIGN

TANK

TANK

TANK

SIGN

SIGN

OHPL

OHPL

O H P L

O H P L

O H P L

O H P L

S M

A R

IO

N

A V

E

LT PL

ANCH(2)

PP

FOCJB

C O N C

C O N C

C O N C

C O N C

C O N C

C O N C

C O N C

TELPED

TELPED

F H

FH

N

1°

'3

.4 C (N

1°

' 1

.3

RUIN

STAIRS

AC

AC

AC

AC

PUMPS

STAIRS

TANK

POOL

SIGN

TANK

TANK

TANK

SIGN

SIGN

OHPL

OHPL

O H P L

O H P L

O H P L

O H P L

HH

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH PULL

STRING. CONDUITS ROUTED BELOW GRADE.

HH

(4) 4" CONDUITS, (1) WITH CORE-A FIBER

OPTIC CABLE, (1) WITH CORE-B FIBER OPTIC

CABLE AND (2) SPARE WITH PULL STRING.

CONDUITS ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(4) 4" CONDUITS, (1) WITH CORE-A FIBER OPTIC

CABLE, (1) WITH CORE-B FIBER OPTIC CABLE

AND (2) SPARE WITH PULL STRING. CONDUITS

ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH PULL

STRING. CONDUITS ROUTED BELOW GRADE.

(4) 4" CONDUITS, (1) WITH CORE-A FIBER

OPTIC CABLE, (1) WITH CORE-B FIBER OPTIC

CABLE AND (2) SPARE WITH PULL STRING.

CONDUITS ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(4) 4" CONDUITS, (1) WITH CORE-A

FIBER OPTIC CABLE, (1) WITH CORE-B

FIBER OPTIC CABLE AND (2) SPARE

WITH PULL STRING. CONDUITS

ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH PULL

STRING. CONDUITS ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE

WITH PULL STRING. CONDUITS

ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

HH

HH

HH

HH

HH

HH

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

HH

HH

1 TYPICAL

(3) 4" CONDUITS, (2) SPARE WITH PULL

STRING. CONDUITS ROUTED BELOW GRADE.

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE

HH

(3) 4" CONDUITS, (2) SPARE WITH

PULL STRING. CONDUITS ROUTED

BELOW GRADE.

50'

MINIMUM

HH

(1) 4" CONDUIT. CONDUITS

ROUTED BELOW GRADE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:0

:2

P

M

TN101

TECHNOLOGY SITE PLAN LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS CVM

100% CONSTRUCTION

DOCUMENTS

CHRISTOPHER VAN METER

RCDD Reg. No. 285002

CODED NOTES:

DRAWING NOTES:

1. UNDERGROUND CONDUIT ROUTING AND HANDHOLE/MANHOLE LOCATIONS INDICATED ON THIS PLAN

ARE DIAGRAMATIC. CONTRACTOR TO COORDINATE EXACT CONDUIT ROUTING AND

HANDHOLE/MANHOLE PLACEMENT WITH EXISTING FILED CONDITIONS AND CIVIL PLANS PRIOR TO

CONSTRUCTION. MAXIMUM CONDUIT LENGTH BETWEEN HANDHOLES IS NOT TO EXCEED 250' OR

CUMULATIVE 180 DEGREES OF CONDUIT BEND. REFER TO DETAIL 10 ON SHEET T-503 FOR

ADDITIONAL INFORMATION.

2. REFER TO FIBER BACKBONE RISER DIAGRAM ON SHEET T-601 FOR ADDITIONAL INFORMATION ON

FIBER OPTIC CABLE TYPES AND QUANTITIES.

3. REFER TO CONCRETE ENCASED DUCTBANK DETAIL ON SHEET T-504.

REFER TO DETAIL 1 ON SHEET T-504 AND DETAIL 10 ON SHEET T-503 FOR ADDITIONAL INFORMATION.

COORDINATE EXACT ENTRY POINT INTO BUILDING WITH ARCHITECTURAL AND STRUCTURAL PRIOR TO

CONSTRUCTION.

SAW CUT, PATCH AND REPAIR ROADWAY TO MATCH SURROUNDING AREA FOR INSTALLATION OF

DUCTBANK.

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

NN

0 15' 30' 60' 90'

1" = 30'

1" = 30'-0"1

TECHNOLOGY SITE PLAN - SOUTH

ELECTRICAL

B2

MECHANICAL

B1

STAIR 1

4A1

AREA IS PART OF

THE PIPE BASEMENT

AND IS NOT

CONDITIONED. IF

DROPS ARE NEEDED,

EXCEPTION WILL BE

REQUIRED.

57a

S1

Q1RST

B62[12A]

B74[13]

B66[11]

B64-A[3] B64-B[2]

B82[9]

B82[8]

B64-D[10]

B19[7]

B64-2[1]B64-A[4]

B64-2[6]

B38[5]

B64-A[11]

TR B10

TR C10B

TR BB01

TR 164D

TR

AB02A

TR 110A

3 4

4 3

REFER TO SHEET

TN100 AND TN101

FOR CONTINUATION

REFER TO SHEET

TN100 AND TN101

FOR CONTINUATION

LOCATION OF

TR ON FLOOR

ABOVE

LOCATION OF

TR ON FLOOR

ABOVE

LOCATION OF

TR ON FLOOR

ABOVE

REFER TO SHEET

TN100 AND TN101

FOR CONTINUATION

REFER TO SHEET

TN100 AND TN101

F…

This is the start of the file's text. The full file is on GovTribe.