Attachment 5 - Final Drawing Set - 4 of 8.pdf

PDF 11 MB Posted

Attached to
Project 573A4-21-700 EHRM Infrastructure Upgrades construction project at the Lake City, FL VAMC
Solicitation number
36C77625B0006
Issued by

About this file

This document is an electrical drawing set (Attachment 5 - Final Drawing Set, part 4 of 8) for the Lake City VA Medical Center's EHRM Infrastructure Upgrades project. The comprehensive electrical design covers infrastructure upgrades across multiple buildings, including Buildings 18, 27, 37, 42, 44, 62, 64, 82, and 92, with a focus on telecommunications rooms, electrical distribution, and power systems. The project involves creating new telecom rooms, upgrading electrical panels, installing new conduits and wiring, and implementing power distribution upgrades across basement, first, second, third, and fourth floor levels.

The project is a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with a construction magnitude between $20 million and $50 million, managed by the Department of Veterans Affairs Technology Acquisition Center Austin. The electrical design includes detailed specifications for electrical distribution, panel schedules, one-line diagrams, equipment connections, and specific requirements for telecommunications infrastructure, with careful attention to existing electrical systems, power routing, and compliance with national electrical codes and standards. Key components include new switchboards, panelboards, conduit installations, and electrical system modifications across multiple campus buildings.

View the file

Other files

File Type Posted
Online Bid Opening Meeting Info.docx DOCX document
Amendment 5 - 36C77625B0006 0005 6-30-25.pdf PDF
Construction Wage Rates - Columbia 6-27-2025.pdf PDF
Brand Name Justification - Lake City - Rev 2 0 - Redacted.pdf PDF
Amendment 4 - 36C77625B0006 0004 6-25-25.pdf PDF
Brand Name Justification - Lake City EHRM - SIGNED_Redacted.pdf PDF
Amendment 3 - 36C77625B0006 0003 6-11-25.pdf PDF
573A4-21-700 Lake City - RFI TRACKING SHEET REV2 36C77625B0006 6-10-25.xlsx XLSX spreadsheet
573A4-21-700 Lake City - Addendum No. 1.pdf PDF
260526-EDITED Grnd shop marked up.docx DOCX document
260533-EDITED Raceway shop marked up.docx DOCX document
260519-EDITED Low Volt cond cab shop marked updocx.docx DOCX document
262726-EDITED Wire Dev shop marked up.docx DOCX document
Construction Wage Rates - Columbia 5-2-2025.pdf PDF
262416-EDITED Panelboards shop marked up.docx DOCX document
Amendment 2 - 36C77625B0006 0002 5-27-2025.pdf PDF
Site Visit Sign-in - 573A4-21-700 Attendance 250423.pdf PDF
Amendment 1 - 36C77625B0006 0001 4-24-25.pdf PDF
Attachment 15 - Construction Wage Rates - Columbia.pdf PDF
Attachment 8 - Final Drawing Set - 7a of 8.pdf PDF
Attachment 4 - Final Drawing Set - 3 of 8.pdf PDF
Attachment 14 - PreConstruction Risk Assessment - Lake City.docx DOCX document
Attachment 9 - Final Drawing Set - 7b of 8.pdf PDF
Attachment 10 - Final Drawing Set - 7c of 8.pdf PDF
Attachment 7 - Final Drawing Set - 6 of 8.pdf PDF
Attachment 6 - Final Drawing Set - 5 of 8.pdf PDF
Attachment 12 - Final Drawing Set - 8 of 8.pdf PDF
Attachment 1 - Final Specs Set - R4.pdf PDF
Attachment 13 - Asbestos and Lead Paint Survey Report.pdf PDF
Attachment 11 - Final Drawing Set - 7d of 8.pdf PDF
Attachment 17 - Site Visit Instructions.pdf PDF
Attachment 3 - Final Drawing Set - 2 of 8.pdf PDF
Attachment 16 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 2 - Final Drawing Set - 1 of 8.pdf PDF
IFB 36C77625B0006.pdf PDF
Attachment 18 - RFI TRACKING SHEET - SOLICITATION 36C77625B0006 - Project 573A4-21-700.xlsx XLSX spreadsheet
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1PH SINGLE-PHASE

3PH THREE-PHASE

4W FOUR-WIRE

A/E ARCHITECT/ENGINEER

AF AMPERE FRAME OR AMP FUSE

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMP AMPERE

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

BLDG BUILDING

C CONDUIT

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

SSTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CKT CIRCUIT

CLG CEILING

COAX COAX CABLE

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUE

COORD COORDINATE

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CU COPPER

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DISC DISCONNECT

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DS DISCONNECT SWITCH

DWG DRAWING

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

ESMT EASEMENT

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

ETR EXISTING TO REMAIN

ELECTRICAL ABBREVIATIONS

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FLA FULL LOAD AMPS

FP FIRE PROTECTION

FT FEET OR FOOT

GND GROUND

G OR GFCI GROUND FAULT CIRCUIT INTERRUPTER

GTB GROUND TERMINAL BOX

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HZ HERTZ

IESNA ILLUMINATION ENGINEERING SOCIETY OF NORTH AMERICA

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

kV KILOVOLT kVA KILOVOLT AMPERE kVAH KILOVOLT AMPERE PER HOUR kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWH KILOWATT HOUR

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LRA LOCKED ROTOR AMPS

LTG LIGHTING

LV LOW VOLTAGE

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MH MANHOLE

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MLO MAIN LUGS ONLY

MTD MOUNTED

MTG MOUNTING

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT MICROWAVE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NEUT OR N NEUTRAL

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

P POLE

PA PUBLIC ADDRESS

PCB POLYCHLORINATED BIPHENYL

PH PHASE

PNL PANEL

POD POWER OPERATED DAMPER

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

RCP REFLECTED CEILING PLAN

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

REQD REQUIRED

SCC SHORT CIRCUIT CAPACITY

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

W WATT

WH WATER HEATER

WP WEATHERPROOF

XFER TRANSFER

XFMR TRANSFORMER

ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION

AWG AMERICAN WIRE GAUGE

KCMIL ONE-THOUSAND CIRCULAR MILS

NA NOT APPLICABLE

HD HEAT DETECTOR

MOTOR CONNECTION

NEW (HEAVY, SOLID LINE)

EXISTING TO REMAIN (LIGHT, SOLID LINE)

EXISTING TO BE REMOVED (HEAVY, DASHED LINE)

ABC

PANELBOARD MAIN CIRCUIT BREAKER TYPE, ONE-LINE

### - INDICATES BREAKER RATING

ABC - INDICATES PANEL DESIGNATION

ABC

PANELBOARD MAIN LUG TYPE, ONE-LINE

### - INDICATES BUS RATING

ABC - INDICATES PANEL DESIGNATION

###A

CIRCUIT BREAKER

### - INDICATES BREAKER RATING

GND GROUND BUS BAR

DISCONNECT SWITCH, FUSED

DISCONNECT SWITCH, UNFUSED

JUNCTION BOX

EARTH GROUND

RECEPTACLE, DUPLEX

RECEPTACLE, DOUBLE DUPLEX (QUADRAPLEX)

RECEPTACLE, SPECIAL PURPOSE, SEE CODED NOTES ON FLOOR PLANS FOR NEMA CONFIGURATION AND WIRING

REQUIREMENTS

ELECTRICAL SYMBOLS - POWER/LIGHTING PLANS

SWITCH (# SUBSCRIPT AS INDICATED BELOW) - SEE PLANS AND SPECIFICATIONS FOR DETAILS

BLANK = SINGLE POLE 2 = DOUBLE POLE

4 = FOUR-WAY

P = WITH PILOT LIGHT

OS= DUAL TECHNOLOGY OCCUPANCY SENSOR WITH RAISE/LOWER

HOA= HAND/OFF/AUTOMATIC

LV= LOW VOLTAGE - SEE BELOW FOR DETAILS

M = MANUAL MOTOR STARTING

MP= MOTOR SNAP WITH PILOT LIGHT

(THERMAL TYPE)

LIGHTING, EXTERIOR BUILDING

J

SYMBOL DESCRIPTION DESCRIPTION DESCRIPTION

SUBSCRIPTS (TYPICAL FOR ALL RECEPTACLES):

G = GFCI TYPE

WP = DEVICE PROVIDED WITH WEATHERPROOF IN-USE METAL COVER

TRANSFORMER, PLANT

TRANSFORMER, ONE-LINE

G

M

ABC

BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, SURFACE MOUNTED

BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, FLUSH MOUNTED

BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, SURFACE MOUNTED

BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, FLUSH MOUNTED

SWITCHBOARD/ SWITCHGEAR/ DISTRIBUTION PANEL, UNDER 250 VOLTS

SWITCHBOARD/ SWITCHGEAR/ DISTRIBUTION PANEL - OVER 250 VOLTS

LOW VOLTAGE SWITCH - SEE PLANS, SPECIFICATIONS AND WIRING DIAGRAMS FOR DETAILS

LV2Dab

S

S

SUBSCRIPT(S) INDICATE FIXTURES CONTROLLED

'D' INDICATES 0-10V DIMMING

'2' INDICATES NUMBER OF LOW VOLTAGE ZONES

'LV' INDICATES LOW VOLTAGE SWITCH

A

EXIT LIGHT, LED, WALL MOUNTED

EXIT LIGHT, LED, CEILING OR PENDANT MOUNTED; DIRECTIONAL ARROWS AS

INDICATED; SHADED QUADRANT INDICATES FACE(S) OF LUMINAIRE

LED, RECESSED, PENDANT OR SURFACE CEILING LUMINAIRE

LED, RECESSED, PENDANT OR SURFACE CEILING LIGHTING FIXTURE

SHADING INDICATES FIXTURE CONNECTED TO EMERGENCY CIRCUIT

(TYPICAL FOR ALL LIGHT FIXTURE SYMBOLS)

LED FIXTURE, RECESSED, PENDANT OR SURFACE CEILING

LED STRIP LUMINAIRE

FIXTURE TYPE

LOWER CASE LETTER INDICATES CONTROLLING SWITCH

a

CIRCUIT NUMBER

LED, WALL MOUNTED LUMINAIRE

DN

UP

CONDUIT CONTINUED

CONDUIT STUBBED OUT OR UP

CONDUIT TURNING DOWN

CONDUIT TURNING UP

CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOROS

GROUND BUS BAR, COPPER

SPD SURGE PROTECTIVE DEVICE

SYMBOL SYMBOL

WALL MOUNTED JUNCTION BOXJ

LPP LIGHTING POWER PACK RELAY

a

SUBSCRIPT INDICATES CONTROLLING SWITCH AND FIXTURES CONTROLLED (TYPICAL)

LPE EMERGENCY LIGHTING POWER PACK RELAY - UL924 COMPLIANT

DOUBLE TUB PANELBOARD, ONE-LINE

ABC - INDICATES PANEL DESIGNATION

METER, ONE-LINE

TRANSFER SWITCH, ONE-LINE

GENERATOR, ONE-LINE

UNINTERRUPTIBLE POWER SUPPLY (UPS), ONE-LINE

ELECTRICAL ONE-LINE

###A BRANCH CIRCUIT BREAKER

### - INDICATES BREAKER RATING

GEN GENERATOR

CNTRL CONTROL

M METER

EMERGENCY POWER OFF BUTTON WITH PROTECTIVE COVER

ALL PATHWAY ROUTING AND LAYOUT IS DIAGRAMMATIC BY NATURE AND FIELD CONDITIONS MAY CHANGE BETWEEN FIELD VERIFICATION OF EOR AND CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND

COORDINATE SPACE REQUIREMENTS AND ACCESS REQUIREMENTS WITH THE LOCAL STATION VA COR AND FACILITIES TEAM. CONTRACTOR SHALL NOTIFY OF ANY OUTAGE A MINIMUM OF 4 WEEKS IN ADVANCE BUT IS NOT

RELIEVED OF ADDITIONAL TIME REQUESTED FOR OUTAGE NOTIFICATION BY THE VA.

PROVIDE MANUFACTURER START UP BUT AT A MINIMUM PROVIDE THE FOLLOWING:

1. LOAD BANK RATED AT 100% OF FULL LOAD CAPACITY OF THE UPS SYSTEM FOR TESTING AND BURN IN OF THE UPS.

2. PROVIDE A MINIMUM OF 12 HOUR BURN IN TIME STEPPING TO FULL LOAD IN 25% INCREMENTS WITH 100% LOAD RUNNING FOR A MINIMUM OF 4 HOURS.

3. PROVIDE FAIL OVER SITUATIONS FAILING NORMAL AND EMERGENCY POWER TO THE UPS.

DURING COMMISSIONING OF THE UPS RECORD ALL BATTERY VOLTAGES, INPUT AND OUTPUT VOLTAGES OF THE SYSTEM, AND BATTERY BEGINNING OF LIFE RUN.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:5

P M

E-001

ELECTRICAL LEGENDS &

SYMBOLS

LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

SHEET LIST

SHEET NUMBER SHEET NAME

E-001 ELECTRICAL LEGENDS & SYMBOLS

E-002 ELECTRICAL GENERAL NOTES

E1.B BASEMENT - ZONES - NEW

E1.B.2 BLDG 64 - LV B - ZONE 2 - NEW

E1.B.3 BLDG 64 - LV B - ZONE 3 - NEW

E1.B.6 BLDG 64 - LV B - ZONE 6 - NEW

E1.B.7 BLDG 19 - LV B - ZONE 7 - NEW

E1.B.9 BLDG 82 - LV B - ZONE 9 - NEW

E1.B.11 BLDG 66 - LV B - ZONE 11 - NEW

E1.B.12 BLDG 62 - LV B - ZONE 12B - NEW

E1.1 FIRST FLOOR LEVEL - ZONES - NEW

E1.1.2 BLDG 64 - LV 1 - ZONE 2 - NEW

E1.1.3 BLDG 64 - LV 1 - ZONE 3 - NEW

E1.1.5 BLDG 38 - LV 1 - ZONE 5 - NEW

E1.1.6 BLDG 64 - LV 1 - ZONE 6 - NEW

E1.1.7 BLDG 19 - LV 1 - ZONE 7 - NEW

E1.1.9 BLDG 82 - LV 1 - ZONE 9 - NEW

E1.1.12 BLDG 62 - LV 1 - ZONE 12B - NEW

E1.1.14 BLDG 27 & 37 - ZONE 14 - NEW

E1.1.15 BLDG 18, 42, 44 & 92 - ZONE 15 - NEW

E1.2 SECOND FLOOR - ZONES - NEW

E1.2.2 BLDG 64 - LV 2 - ZONE 2 - NEW

E1.2.3 BLDG 64 - LV 2 - ZONE 3 - NEW

E1.2.5 BLDG 38 - LV 2 - ZONE 5 NEW

E1.2.9 BLDG 82 - LV 2 - ZONE 9 - NEW

E1.2.12 BLDG 62 - LV 2 - ZONE 12B - NEW

E1.3 THIRD FLOOR - ZONES - NEW

E1.3.3 BLDG 64 - LV 3 - ZONE 3 - NEW

E1.3.5 BLDG 38 - LV 3 - ZONE 5 - NEW

E1.3.9 BLDG 82 - LV 3 -ZONE 9 - NEW

E1.4 FOURTH FLOOR - ZONES - NEW

E1.4.3 BLDG 64A - LV 4 - ZONE 3 - NEW

E-400 DATA CENTER

E-401 ENLARGED ROOM PLANS

E-402 ENLARGED ROOM PLANS

E-403 ENLARGED ROOM PLANS

E-404 ENLARGED ROOM PLANS

E-405 ENLARGED ROOM PLANS

E-406 ENLARGED ROOM PLANS

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS

E-601 ELECTRICAL DIAGRAMS

E-602 ELECTRICAL DIAGRAMS

E-603 ELECTRICAL DIAGRAMS

E-604 ELECTRICAL DIAGRAMS

E-605 ELECTRICAL DIAGRAMS

E-606 ELECTRICAL DIAGRAMS

E-607 ELECTRICAL DIAGRAMS

E-608 ELECTRICAL DIAGRAMS

SHEET LIST

SHEET NUMBER SHEET NAME

E-801 ELECTRICAL SCHEDULES

E-802 ELECTRICAL SCHEDULES

E-803 ELECTRICAL SCHEDULES

E-804 ELECTRICAL SCHEDULES

E-805 ELECTRICAL SCHEDULES

E-806 ELECTRICAL SCHEDULES

E-807 ELECTRICAL SCHEDULES

E-808 ELECTRICAL SCHEDULES

E-809 ELECTRICAL SCHEDULES

E-810 ELECTRICAL SCHEDULES

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523 Revisions Date

12/31/2024

ELECTRICAL GENERAL NOTES

WHERE THERE IS A DISCREPANCY BETWEEN ABOVE GENERAL NOTES AND SPECIFICATIONS, WHERE APPLICABLE, SPECIFICATIONS SHALL BE FOLLOWED

APPLICABLE CODES

1. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), INCLUDING (BUT NOT LIMITED TO):

a. NATIONAL ELECTRICAL CODE (NEC), NFPA 70 - 2023

b. NATIONAL FIRE ALARM CODE, NFPA 72 - 2022

c. LIFE SAFETY CODE, NFPA 101 – 2021

d. EMERGENCY AND STANDBY POWER SYSTEMS, NFPA 110 – 2022

e. HEALTH CARE FACILITIES CODE, NFPA 99

2. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI), INCLUDING (BUT NOT LIMITED TO):

a. NATIONAL ELECTRICAL SAFETY CODE, ANSI C2

3. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)

4. FACILITY GUIDELINES INSTITUTE (FGI):

a. GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND OUTPATIENT FACILITIES

5. FEDERAL COMMUNICATION COMMISSION (FCC)

6. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

7. INSULATED CABLE ENGINEERS ASSOCIATION (ICEA)

8. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)

9. NATIONAL ELECTRICAL TESTING ASSOCIATION (NETA)

10. AMERICAN SOCIETY OF TESTING AND MATERIALS (ASTM)

11. ILLUMINATION ENGINEERING SOCIETY (IES)

12. ANTI-FRICTION BEARING MANUFACTURERS ASSOCIATION (AFBMA)

13. BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA)

14. INTERNATIONAL CODE COUNCIL (ICC):

a. INTERNATIONAL BUILDING CODE (IBC)

15. UNIFORM BUILDING CODE (UBC)

16. COMBINED ANSI/ASHRAE/IES STANDARD 90.1 – “ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL

BUILDINGS”

17. NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION INSTALLATION STANDARDS (NECA)

18. AMERICANS WITH DISABILITIES ACT (ADA)

19. APPLICABLE STATE AND LOCAL CODES, AMENDMENTS, REGULATIONS, AND PRACTICES.

20. APPLICABLE REGULATORY REQUIREMENTS AND ADVISORY PRACTICES OF APPROPRIATE

a. AUTHORITIES HAVING JURISDICTION (AHJs).

21. APPLICABLE STANDARDS, REGULATIONS, AND PRACTICES OF THE OWNER.

1. THE DRAWINGS AND APPLICABLE SPECIFICATIONS SHALL BE CONSIDERED SUPPLEMENTARY, ONE TO THE OTHER AND ARE CONSIDERED THE "CONTRACT DOCUMENTS". ALL WORKMANSHIP, METHODS AND/OR MATERIALS DESCRIBED OR IMPLIED BY ONE AND NOT DESCRIBED OR IMPLIED BY THE OTHER SHALL BE PROVIDED, FURNISHED OR PERFORMED AS IF IT HAD APPEARED IN BOTH SECTIONS. THE TERM "CONTRACT DOCUMENTS" DESCRIBED HEREIN IS NOT LIMITED SOLELY TO THE ELECTRICAL PORTION OF THE DRAWINGS AND SPECIFICATIONS, BUT

ENCOMPASSES THE DRAWINGS AND SPECIFICATIONS OF ALL DIVISIONS AS A WHOLE.

2. PROVIDE AN OPERATING AND MAINTENANCE MANUAL TO OWNER PRIOR TO THE FINAL ACCEPTANCE. THE MANUAL SHALL INCLUDE, AS A MINIMUM, (1) SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. ALSO PROVIDE TWO OPERATIONS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS AND METHOD OF OPERATION FOR EQUIPMENT SHALL BE CLEARLY IDENTIFIED, AND THE NAME, PHONE NUMBER AND

ADDRESS OF AT LEAST ONE QUALIFIED SERVICE AGENCY.

3. INCLUDE ALL COSTS FOR EXCAVATION, SAW CUTTING, DIRECTIONAL BORING, CORE DRILLING, BACKFILLING, SURFACE RESTORATION, REPAIR OF FINISHES, ETC. THAT IS REQUIRED IN ORDER TO MEET THE PROJECT

REQUIREMENTS.

4. INCLUDE IN BID ALL COSTS ASSOCIATED WITH TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR USE BY ALL TRADES DURING CONSTRUCTION. REMOVE TEMPORARY POWER AT THE COMPLETION OF THE PROJECT. OBTAIN AND PAY FOR ALL REQUIRED PERMITS FOR TEMPORARY POWER. ENGINEER OF RECORD SHALL BE PROVIDED WITH ADDITIONAL COMPENSATION FROM THE CONTRACTOR WHERE SIGNED & SEALED DRAWINGS ARE REQUESTED BY THE CONTRACTOR TO THE ENGINEER OF RECORD IF REQUIRED BY THE AHJ FOR THE TEMPORARY POWER.

5. LOCATE, IDENTIFY, PROTECT AND DOCUMENT ALL UTILITY LINES LOCATED WITHIN THE PROJECT BOUNDARY. FOR LOCATING SITE UTILITIES, CONTACT SUNSHINE STATE ONE CALL OF FLORIDA, INC. AT LEAST 48 HOURS IN ADVANCE

PRIOR TO DIGGING, AT 1-800-432-4770.

6. INCLUDE IN BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF ALL WASTE MATERIALS GENERATED BY THIS PROJECT IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL RULES, REGULATIONS AND GUIDELINES APPLICABLE. COMPLY FULLY WITH FLORIDA STATUTES REGARDING MERCURY-CONTAINING DEVICES, AND WITH ALL DEP AND EPA APPLICABLE GUIDELINES AT THE TIME OF DISPOSAL. PROVIDE OWNER WITH WRITTEN CERTIFICATION

OF ACCEPTED DISPOSAL.

7. ALL POWER CIRCUITS HAVE BEEN DESIGNED IN COMPLIANCE WITH FLORIDA BUILDING CODE REQUIRING 2% OR

LESS VOLTAGE DROP FOR FEEDERS, AND 3% OR LESS VOLTAGE DROP FOR BRANCH CIRCUITS.

8. ALL BRANCH CIRCUITS SHALL BE FURNISHED WITH A DEDICATED NEUTRAL. SHARED NEUTRALS ARE NOT ALLOWED

UNLESS SPECIFICALLY NOTED ON THE DRAWINGS.

9. VERIFY AND COORDINATE LOCATIONS AND EXACT ELECTRICAL REQUIREMENTS FOR ALL MECHANICAL, PLUMBING AND FIRE PROTECTION EQUIPMENT PRIOR TO SUBMITTAL OF SHOP DRAWINGS OF ELECTRICAL EQUIPMENT.

PROVIDE ALL NECESSARY RACEWAYS, CONDUCTORS, BOXES, EQUIPMENT, ACCESSORIES, ASSOCIATED DISCONNECT SWITCHES, CIRCUIT BREAKERS, CONTROL TRANSFORMERS, FIRE ALARM SHUTDOWN, ETC. REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. COORDINATE WITH APPROPRIATE TRADE'S APPROVED SHOP DRAWINGS, MANUFACTURER'S INSTRUCTIONS, AND EQUIPMENT NAMEPLATE INFORMATION, PRIOR TO ROUGH IN, AND PROVIDE ALL NECESSARY ELECTRICAL REQUIRED, UNLESS OTHERWISE NOTED.

10. ALL WORK ON THE ELECTRICAL SYSTEM REQUIRED BY THE CONTRACT DOCUMENTS SHALL BE COORDINATED WITH THE WORK OF ALL OTHER DIVISIONS/TRADES PRIOR TO COMMENCEMENT OF WORK. AVOID INTERFERENCES WITH

THE PROGRESS OF OTHER DIVISIONS/TRADES.

11. LOCATIONS OF DISCONNECTS. FOR HVAC EQUIPMENT ARE DIAGRAMMATIC ON THE PLAN DRAWINGS. EXACT LOCATIONS ARE TO BE COORDINATED WITH CONTRACTOR'S COORDINATION DRAWINGS PRIOR TO ROUGHING IN

TO ENSURE PROPER NEC CLEARANCES AND APPROPRIATE MOUNTING SURFACE.

12. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. PROVIDE COMPONENTS

INDICATED ON RISER DIAGRAMS WHETHER OR NOT INDICATED ON PLANS AND VICE VERSA.

13. ROUTING OF CONDUIT IS DIAGRAMMATIC AND NOT INTENDED TO SHOW REQUIRED OFFSETS AND DETAILS.

COORDINATE EXACT ROUTING WITH FIELD CONDITIONS AND OTHER TRADES.

14. REFER TO ARCHITECTURAL, MECHANICAL, TECHNOLOGY AND STRUCTURAL DRAWINGS FOR RELATED INFORMATION AND ADDITIONAL INSTALLATION REQUIREMENTS TO BE PERFORMED AS PART OF THE WORK. REFER TO

ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING HEIGHT AND LOCATIONS.

15. WHERE A DISCREPANCY OR CONFLICT IS FOUND BETWEEN ONE DRAWING AND ANOTHER, OR BETWEEN A DRAWING AND APPLICABLE SPECIFICATIONS, NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY IN WRITTEN FORM. IN GENERAL, THE MOST STRINGENT REQUIREMENT SHALL GOVERN UNLESS THE DISCREPANCY CONFLICTS WITH APPLICABLE CODES OR OWNER'S DESIGN STANDARDS, WHEREIN THE CODE OR OWNER'S DESIGN STANDARDS SHALL GOVERN.

16. COORDINATE ALL PROJECT SCHEDULING AND PHASING REQUIREMENTS WITH ARCHITECT/ENGINEER AND OWNER PRIOR TO SUBMITTING BID PRICE. THIS PROJECT MAY REQUIRE PHASING SEQUENCES AND POTENTIAL PREMIUM TIME WORK AND ALL COSTS FOR SUCH SHALL BE INCLUDED IN THE BID PRICE. PROVIDE ADEQUATE WORK FORCE AND EQUIPMENT, AND INCLUDE PREMIUM TIME AS MAY BE REQUIRED IN ORDER TO ADHERE TO THE PROJECT SCHEDULE. ADDITIONALLY, ENSURE THAT LONG LEAD ITEMS DO NOT IMPACT THE PROJECT'S SCHEDULE OR

PHASING.

17. ANY TEMPORARY INTERRUPTION ON POWER REQUIRED FOR THE SYSTEM TIE-IN OR SWITCHOVER FOR ANY PORTION OF THE ELECTRICAL SYSTEM SHALL BE PRE-APPROVED IN WRITING BY THE OWNER AND SCHEDULED IN

ADVANCE.

18. COORDINATE EXACT REQUIREMENTS WITH PROVIDERS (ELECTRIC, TELEPHONE, CABLE TV, ETC.) AND INCLUDE ALL COSTS FOR PROVIDING TEMPORARY AND PERMANENT SERVICES REQUIRED FOR THIS PROJECT IN THE BID PRICE.

BID PRICE SHALL INCLUDE, BUT NOT BE LIMITED TO, EXCAVATION, RACEWAYS, BACKFILL, EQUIPMENT, EQUIPMENT

PADS, BACKBOARDS, METERS, GROUNDING, UTILITY ENGINEERING AND IMPACT FEES.

19. CONDUCT WORK OPERATIONS AND DEBRIS REMOVAL IN A MANNER THAT ENSURES MINIMUM INTERFERENCE WITH NORMAL BUSINESS OPERATIONS, TRAFFIC, PARKING, ETC. ONGOING IN ADJACENT OCCUPIED SPACES OR FACILITIES. PROVIDE ALL THAT IS REQUIRED TO EFFECTIVELY PROTECT SURROUNDING OCCUPANTS, EQUIPMENT, FINISHES, FURNITURE, ETC. FROM DAMAGE OR EXCESSIVE NOISE THROUGHOUT THE DURATION OF THIS PROJECT.

CONTRACTOR IS RESPONSIBLE FOR ANY LOSSES OR DAMAGE. ANY DAMAGE RESULTING FROM THE FAILURE TO ADHERE TO THIS REQUIREMENT. RESTORE DAMAGED ELEMENTS TO ORIGINAL CONDITION BY THE CONTRACTOR TO THE SATISFACTION OF THE ARCHITECT/ENGINEER AND OWNER, AT NO ADDITIONAL COSTS. REPORT OF ANY SUCH OCCURRENCE TO THE ARCHITECT/ENGINEER AND OWNER IMMEDIATELY AND AWAIT WRITTEN DIRECTION PRIOR TO

PROCEEDING WITH REPAIRS.

20. COORDINATE THE LOCATION OF ALL LIGHT FIXTURES, DEVICES AND BOXES WITH WINDOWS, MIRRORS, MILLWORK, CABINETS, GLASS CURTAIN WALLS, AND GLASS WALLS PRIOR TO INSTALLATION OF CONDUITS OR BOXES. REVIEW ALL CONTRACT DRAWINGS TO ASCERTAIN ANY CONFLICTS PRIOR TO BIDDING. OBTAIN CLARIFICATION FROM A/E PRIOR TO BID. CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL COMPENSATION FOR WORK REQUIRED TO

RELOCATE OUTLET BOXES OR RACEWAYS FOR COORDINATION WITH OTHER TRADE'S WORK.

21. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO 6' ABOVE EQUIPMENT OR STRUCTURAL CEILING, WHICHEVER DISTANCE IS LOWER, WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL

APPURTENANCES IN ACCORDANCE WITH NEC.

22. PROVIDE ALL TEMPORARY NORMAL LIGHTING, EMERGENCY LIGHTING AND EXIT SIGNAGE REQUIRED DURING THE

PROJECT CONSTRUCTION PHASE.

23. THE INFRASTRUCTURE FOR THE ACCESS CONTROL/ SSTV OR SECURITY ELECTRONICS SYSTEM (CONDUITS, ELECTRICAL BOXES) SHALL BE INSTALLED BY DIVISION 26. THE ACCESS CONTROL/SSTV OR SECURITY ELECTRONICS SYSTEM CONTRACTOR SHALL PROVIDE AND INSTALL THE WIRE AND CABLE FOR THE SYSTEM AND ALL REQUIRED EQUIPMENT. INSTALLATION OF THE CONDUITS AND ELECTRICAL BOXES SHALL BE UNDER THE DIRECT SUPERVISION OF THE ACCESS CONTROL/ SSTV SYSTEM CONTRACTOR. COORDINATE EXACT LOCATIONS OF DEVICES, RACEWAY

LOCATIONS, SIZES AND QUANTITY, CONDUIT STUB-UPS PRIOR TO ROUGH IN.

24. THE INFRASTRUCTURE FOR THE VOICE/DATA TELECOMMUNICATIONS SYSTEM (CONDUITS, ELECTRICAL BOXES) SHALL BE INSTALLED BY DIVISION 26. THE TELECOMMUNICATIONS CONTRACTOR SHALL PROVIDE AND INSTALL THE WIRE AND CABLE FOR THE SYSTEM AND ALL REQUIRED EQUIPMENT AND COMPONENTS. INSTALLATION OF THE CONDUITS AND ELECTRICAL BOXES SHALL BE UNDER THE DIRECT SUPERVISION OF THE TELECOMMUNICATIONS CONTRACTOR. COORDINATE EXACT LOCATIONS OF DEVICES, RACEWAY LOCATIONS, SIZES AND QUANTITY, CONDUIT

STUB-UPS PRIOR TO ROUGH IN.

25. UNLESS NOTED AS EXISTING, ALL ELECTRICAL INDICATED ON THE CONTRACT DOCUMENTS SHALL BE NEW, SHALL BE U.L.

LISTED, AND SHALL BEAR A U.L. LABEL. WHERE NO U.L. LABEL OR LISTING IS AVAILABLE, THE MATERIAL SHALL BE LISTED

WITH AN APPROVED, NATIONALLY RECOGNIZED ELECTRICAL TESTING AGENCY.

26. PROVIDE EXPERIENCED, QUALIFIED AND RESPONSIBLE SUPERVISION FOR ALL WORK REQUIRED BY THE CONTRACT DOCUMENTS. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, TO THE

SATISFACTION OF THE ARCHITECT/ENGINEER AND OWNER.

27. THE ELECTRICAL PORTION OF THE CONTRACT DOCUMENTS ARE COORDINATED WITH THE DESIGN BASIS EQUIPMENT SPECIFIED BY DIVISION 26 AND OTHER DIVISIONS. WHERE THE CONTRACTOR ELECTS TO SUBSTITUTE A PRODUCT IN LIEU OF PROVIDING THE DESIGN BASIS, AND SAID SUBSTITUTION IS ACCEPTED BY THE A/E AND OWNER, THE CONTRACTOR SHALL MAKE ALL CORRECTIONS TO THE ELECTRICAL SYSTEM NECESSARY IN ORDER TO ENSURE A COMPLETE AND OPERATIONAL INSTALLATION OF THE EQUIPMENT AT NO ADDITIONAL COSTS. WHERE THE CONTRACTOR'S DESIGN SUBSTITUTION RESULTS IN THE NEED FOR THE ENGINEER TO REVISE THE CONTRACT DOCUMENTS, THE ENGINEER RESERVES THE RIGHT TO

REQUEST COMPENSATION FROM THE CONTRACTOR FOR SAID SERVICES.

28. MAINTAIN A CURRENT AND ACCURATE SET OF PROJECT RECORD DOCUMENTS (AS-BUILTS) AT THE SITE THROUGHOUT THE DURATION OF THE PROJECT. RECORD DRAWINGS SHALL BE UPDATED EACH DAY TO REFLECT THE ACTUAL LOCATIONS, SIZES, ROUTING, ETC. OF EACH PORTION OF THE ELECTRICAL SYSTEM AFFECTED BY THIS WORK. A FINAL SET OF RECORD DOCUMENTS SHALL BE ISSUED TO THE A/E FOR REVIEW AND THEN SUBMITTED TO THE OWNER WITHIN 30 DAYS AFTER THE DATE OF FINAL ACCEPTANCE. PROVIDE RECORD DRAWINGS OF THE ACTUAL INSTALLATION INCLUDING SINGLE LINE DIAGRAM, POWER RISER DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM, SITE PLANS AND ALL ELECTRICAL

FLOOR PLANS, DETAILS, PANEL SCHEDULES, ETC.

29. OWNER FURNISHED EQUIPMENT: VERIFY AND COORDINATE ELECTRICAL ROUGH IN REQUIREMENTS FOR OWNER

FURNISHED EQUIPMENT PRIOR TO ROUGH IN.

30. WHERE SUBMITTED EQUIPMENT REQUIRES REVISION TO OVERCURRENT PROTECTION, CONDUIT OR WIRING, MAKE

CHANGES IN ACCORDANCE WITH APPLICABLE CODES.

ELECTRICAL DEMOLITION NOTES

1. THE FACILITY WILL REMAIN OCCUPIED DURING RENOVATIONS.

2. DEVICES, LIGHT FIXTURES AND EQUIPMENT SHOWN IN DASHED LINE TYPE ARE EXISTING TO BE DEMOLISHED; DEVICES, LIGHT

FIXTURES AND EQUIPMENT SHOWN IN LIGHT SOLID LINE TYPE ARE EXISTING TO REMAIN, UNLESS OTHERWISE NOTED.

3. EXISTING EQUIPMENT, LIGHT FIXTURES, DEVICES SHOWN ARE BASED ON FIELD SURVEYS AND RECORD DRAWINGS PROVIDED

BY THE OWNER, AND IS NOT NECESSARILY ALL INCLUSIVE IN EVERY AREA AS FAR AS EXISTING ELECTRICAL EQUIPMENT, LIGHT FIXTURES AND DEVICES. EXISTING CIRCUITING SHOWN IS BASED ON RECORD DRAWINGS AND THE SURVEYED PANEL DIRECTORIES, WHERE THEY WERE AVAILABLE. THE ACTUAL CONDITIONS MAY VARY. ALL EXISTING CONDITIONS MUST BE VERIFIED PRIOR TO BID. THE CONDITIONS SHOWN ARE INTENDED TO SHOW THE LOCATIONS OF EXISTING DEVICES, LIGHT FIXTURES AND EQUIPMENT, WHERE SHOWN ON THE PLAN DRAWINGS, AND IN NO WAY RELIEVES THE CONTRACTOR FROM PROVIDING ANY AND ALL COORDINATION NECESSARY TO COMPLETE THE NEW WORK. FIELD CONDITIONS SHALL GOVERN.

4. WHERE EXISTING DEVICES ARE INDICATED TO REMAIN OR RELOCATED, LOCATED WITHIN THE SCOPE OF THIS PROJECT AND EXISTING CIRCUITING INFORMATION IS UNAVAILABLE, CONTRACTOR IS TO PROVIDE CIRCUIT TRACING TO IDENTIFY PANEL AND CIRCUIT DEVICES ARE CONNECTED TO AND PROVIDE THAT INFORMATION TO A/E PRIOR TO ROUTING CONDUITS AND WIRING

FOR NEW DEVICES AND EQUIPMENT WITHIN THE SCOPE OF THIS PROJECT.

5. PRIOR TO DEMOLITION, FIELD VERIFY CONDUIT AND WIRING WHICH SERVES AREAS OUTSIDE THE SCOPE OF WORK AND

PASSES THROUGH THE AREA OF WORK. MAINTAIN CONTINUITY OF SYSTEMS.

6. WHERE EXISTING DEVICES ARE TO REMAIN, CONTRACTOR MUST EXTEND EXISTING CIRCUITING WHERE NECESSARY TO

MAINTAIN CONTINUITY OF CIRCUIT.

7. COORDINATE WITH THE OWNER FOR DISPOSITION OF ELECTRICAL ITEMS TO BE DEMOLISHED. OWNER SHALL HAVE THE OPTION TO RETAIN REUSABLE ITEMS SUCH AS COVERPLATES, RECEPTACLES, LIGHT FIXTURES, PANELBOARDS, TRANSFORMERS, ETC. NOT BEING USED IN THE FINISHED WORK. COORDINATE WITH THE OWNER PRIOR TO START OF DEMOLITION. PROPERLY AND LEGALLY DISPOSE OF ALL EQUIPMENT AND MATERIALS BEING REMOVED.

8. COORDINATE EXACT AREAS, WALLS, CEILINGS, ETC. TO BE DEMOLISHED WITH ARCHITECTURAL, STRUCTURAL, PLUMBING AND

MECHANICAL DEMOLITION PLANS.

9. WHERE EXISTING DEVICES, LIGHT FIXTURES AND EQUIPMENT ARE INDICATED TO BE DEMOLISHED, REMOVE ASSOCIATED CONDUIT AND WIRING BACK TO SOURCE PANEL OR TO NEAREST JUNCTION BOX TO MAINTAIN CIRCUIT CONTINUITY OF DEVICES TO REMAIN AND EQUIPMENT TO REMAIN. WHERE PANELS ARE TO BE REMAIN, TURN BREAKER TO "OFF" POSITION

AND LABEL THE CIRCUIT AS "SPARE" ON THE PANEL DIRECTORY.

10. ALL AREAS OUTSIDE THE SCOPE OF CONSTRUCTION ARE TO REMAIN ENERGIZED. COORDINATE PHASING WITH CONSTRUCTION MANAGER AND OWNER PRIOR TO DEMOLITION WHICH MAY RESULT IN INTERRUPTION OF POWER.

11. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR EXTENT OF AREA REQUIRING DEMOLITION AND ADDITIONAL INFORMATION ON ELECTRICAL DEMOLITION WITHIN THAT AREA. DISCONNECT ELECTRICAL SERVICE TO ALL EQUIPMENT BEING REMOVED. DEMOLITION SHALL BE PHASED AS REQUIRED BY DIVISION 1, OR DIRECTED BY THE OWNER.

12. REMOVE ALL CONDUIT LEFT EXPOSED BY REMOVAL OF WALLS AND CEILINGS IN REMODELED OR RENOVATED AREA. CAP BOTH ENDS OF REMAINING CONDUIT IN WALL OR FLOOR WHERE CUT. REMOVE ALL ASSOCIATED SUPPORTS. REMOVE WIRING

BACK TO SOURCE OF VOLTAGE.

13. ELECTRICAL DEVICES WITHIN THE AREA OF WORK., AND NOT NOTED ON THE DEMOLITION DRAWINGS, WHETHER DUE TO CONCEALMENT BY STORAGE SHELVING, CASEWORK, FURNITURE OR FOR OTHER REASONS, ARE TO BE REMOVED AS

REQUIRED, UNLESS SHOWN AS EXISTING TO REMAIN.

14. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING ALL OPENINGS IN EXISTING CONSTRUCTION AFTER REMOVAL OF EQUIPMENT AND ELECTRICAL DEVICES, UNLESS OTHERWISE NOTED ON ARCHITECTURAL PLANS. REPAIRS ARE TO BE DONE TO LOGICAL EDGES OF SURFACES AFFECTED AND SHALL MATCH IMMEDIATE ADJACENT AREAS IN CONSTRUCTION, MATERIAL, FIRE RATING, FINISH AND COLOR.

15. PROVIDE BLANK COVERPLATES WHERE DEVICES ARE BEING REMOVED FROM EXISTING WALLS TO REMAIN. MATCH COLOR OF

NEW ADJACENT DEVICE COVERPLATES.

16. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO COMMENCEMENT OF WORK AND OBTAIN

CLARIFICATIONS FROM ARCHITECT/ENGINEER IF NECESSARY.

17. COORDINATE SERVICE INTERRUPTION WITH CONSTRUCTION MANAGER, WHERE APPLICABLE, AND DO NOT INTERRUPT POWER WITHOUT WRITTEN PERMISSION. PROVIDE A MINIMUM OF ONE WEEK'S WRITTEN NOTIFICATION WHEN POWER IS

DESIRED TO BE INTERRUPTED.

18. EXERCISE EXTREME CAUTION WHEN REMOVING/ RELOCATING WIRING AND EQUIPMENT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT OTHER WIRING DEVICES, EQUIPMENT AND LIGHT FIXTURES THAT MAY BE CONNECTED TO

THE SAME CIRCUIT REMAIN OPERATIONAL AND ACTIVE.

19. INFORMATION INDICATED IN THE DEMOLITION PORTION OF THE CONTRACT DRAWINGS IS DIAGRAMMATIC IN NATURE. FIELD VERIFY ELECTRICAL CIRCUIT HOMERUNS TO ALL ELECTRICAL ITEMS SCHEDULED TO BE DEMOLISHED AND PERFORM THE

WORK AS INTENDED AND DEPICTED ON THE DRAWINGS.

20. UPDATE ALL EXISTING ELECTRICAL EQUIPMENT NAMEPLATES AND DIRECTORIES AS NECESSARY TO REFLECT FINAL AS-BUILT

CONDITIONS AT THE END OF CONSTRUCTION.

21. STORE ITEMS INDICATED TO BE RETURNED TO THE OWNER IN A DRY, CLEAN AND PROTECTED AREA. NOTIFY OWNER WHEN

ITEMS ARE READY TO BE REMOVED.

22. SCHEDULE ALL POWER INTERRUPTION WITH OWNER FOR EXACT DATE, TIME AND DURATION. PROVIDE A MINIMUM OF 72 HOURS NOTICE PRIOR TO DISCONNECTING ANY POWER TO ANY PORTION OF THE BUILDING, AND MAKE ARRANGEMENTS TO MAINTAIN POWER TO ALL CRITICAL EQUIPMENT AS NEEDED AND REQUESTED BY THE OWNER PRIOR TO COMMENCEMENT OF

WORK.

23. PROVIDE ANY NECESSARY REPROGRAMMING OF EXISTING BUILDING FIRE ALARM SYSTEMS TO DISABLE FIRE ALARM DEVICES THAT ARE BEING DISCONNECTED AND REMOVED, AND FOR ANY NEW DEVICES THAT ARE ADDED, AS PART OF BID PRICE.

24. THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL ELECTRICAL DEVICES WITHIN THE PROJECT AREA. IT IS INTENDED TO PROVIDE A GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. ANY DISCREPANCIES OR CONDITIONS NOT SHOWN ON THE PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE A/E. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED ELECTRICAL DEMOLITION WHETHER INDICATED ON THE PLANS OR NOT.

25. ALL CONDUITS SERVING OTHER SPACES THAT RUN THROUGH THE PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION SO AS NOT TO CAUSE DISRUPTION TO THESE OTHER SPACES. ENSURE THAT ALL CONDUITS, NEW OR EXISTING WITHIN THE PROJECT AREA ARE PROPERLY SUPPORTED IN ACCORDANCE WITH THE NEC. ANY EXISTING CONDUIT IS INSTALLED BELOW THE HEIGHT OF THE NEW CEILING SHALL BE RELOCATED TO ABOVE THE NEW CEILING HEIGHT.

26. REMOVE ALL ABANDONED WIRING AND CONDUIT THAT IS WITHIN THE PROJECT AREA PRIOR TO THE END OF CONSTRUCTION.

27. UPDATE PANELBOARD DIRECTORIES WHICH ARE MODIFIED BY THIS PROJECT.

28. REPAIR DISTURBED AREAS TO MATCH EXISTING CONDITIONS.

D1.

D2.

D3.

D4.

D5.

D6.

D7.

D8.

D9.

D10.

D11.

D12.

D13.

D14.

D15.

D16.

D17.

D18.

D19.

D20.

D21.

D22.

D23.

D24.

D25.

D26.

D27.

D28.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:5

P M

E-002

ELECTRICAL GENERAL NOTES LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

/4

57a

S1

Q1RST

E-405

NP6B

EP6B

EX. EM

EX. EMG-1A

EX. M

NP164D

EP164D

EPAB18H

CPAB18H

CPBB01

NPBB01

E-401

E-400

NPAB02A

CPAB02A

E-401

E-400

EX. EP-3 EX. LP-3

E-401

E-406

EX. 84-GEN

SWBDH

CPB10

NPB10

CORRIDOR

CB-6

ELEVATOR LOBBY

CB-1x

E-406

1 ELECTRICAL ROOM

LOCATED ON FLOOR ABOVE

ELECTRICAL ROOM

LOCATED ON LEVEL BELOW

CP164D

EP164D

CP251A

EP251A

EP317

CP317

EP400

CP400

E-401

E-401

E-401

SWITCHGEAR

A188

EMERGENCY ELEC

ROOM

A187

CP110A

NP110A

B62[12A]

B75[11]

B74[13]

B66[11]

B64-A[3]

B64-B[2]

B82[9]

B82[8]

B64-D[10]

B19[7]

B64-2[1]B64-A[4]

B64-2[6]

B38[5]

B64-A[11]

ELEC

CB14

E-400

EX. 62 P3

EX. 62 P2

EX. 62 P1

EX. 62 MDP

EX. ATS-1

E-405

CP128A(1ST LEVEL)

NP128A(1ST LEVEL)

CP227A(2ND LEVEL)

NP227B(2ND LEVEL)

ELEC RM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:1

P M

E1.B

BASEMENT - ZONES - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1" = 30'-0"1

ELECTRICAL LOWER LEVEL - ZONES - NEW

CODED NOTES:

DRAWING NOTES:

1. REFER TO ELECTRICAL ONE LINE DIAGRAMS FOR FEEDER SIZE AND CONNECTION INFORMATION.

2. ALL ROUTING LOCATIONS SHOWN ARE PROPOSED. FIELD VERIFY EXACT ROUTING LOCATIONS.

ROUTE FEEDERS DOWN FROM LEVEL ABOVE, THROUGH ACCESSIBLE WALL CHASE. VERIFY EXACT

ROUTING LOCATION PRIOR TO INSTALLATION.

ROUTE FEEDERS FROM BLDG 82 TELECOM ROOMS TO ELECTRICAL RM B2. REFER TO OVERALL PLAN

FOR TELECOM ROOM LOCATION.

ROUTE FEEDERS FROM TELECOM ROOM, UP TO ELECTRICAL ROOM C162A LOCATED A LEVEL ABOVE.

VERIFY EXACT ROUTING LOCATION PRIOR TO INSTALLATION.

ROUTE FEEDERS FROM BUILDING 84, ELECTRICAL ROOM TO TELECOM ROOMS FOR BLDGS 19 AND 64B.

REFER TO E1.1 FOR CONTINUATION. REFER TO ELECTRICAL RISER DIAGRAM FOR MORE INFORMATION.

ROUTE FEEDERS DOWN FROM LEVELS 1 AND 2 TELECOM ROOMS TO ELECTRICAL. ROUTE CONDUITS DOWN FROM LEVEL ABOVE THROUGH CLOSEST ACCESSIBLE CHASE. FIELD VERIFY EXACT ROUTING

LOCATION PRIOR TO INSTALLATION.

NN

0 15' 30' 60' 90'

1" = 30'

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

SPD

STORAGE

BB20

M.S.D.

STORAGE

BB07

BIOMED

BB16

REFRIGERATOR

#1

BB09

FREEZER #1

BB09A

CORRIDOR

CB-13

HVAC MECH.

ROOM

BB15

CART

WASHING

BB13

FREEZER #2

BB11A

REFRIGERATION

MECHANICAL

ROOM

BB14A

INNOVATION

LAB

BB12B

REFRIGERATOR

#2

BB11

CORRIDOR

CB-11

CORRIDOR

CB-12

WELLNESS

EQUIPMENT

BB12Bx

H.A.C.

STORAGE

BB10

M.M.

EQUIPMENT

STORAGE

BB10A

DIETETIC

COOLER #1

BB08

CORRIDOR

CB-10

CORRIDOR

CB-9

H.A.C.

AB28B

ELEVATOR

FREIGHT

F-5/64

TOILET MEN

BB02

TOILET

WOMEN

BB04

H.A.C.

BB05

HVAC

MECHANICAL

ROOM

AB30

SPD CHIEF

BB03A

SPD

CLERICAL

BB03

SPD CLEAN

RECEIVING

BB06

LINEN CHUTE

AB29

ELEVATOR

LOBBY

CB-8

CORRIDOR

CB-7

SPD

DISTRIBUTION

AB28

REFRIGERATION

MECHANICAL

ROOM

BB14

OFFICE

C3-4

F.E.C.

C3-5

ENGINEERING

STORAGE

C3-6

DIETETICS

STORAGE

C3-7

DIETETICS

STORAGE

C3-8

CORRIDOR

C3-11

E-401

CPBB01

NPBB01

B64-FCU-B-BB01

DS-B64-FCU-B-BB01

CONFERENCE ROOM

& TRAINING

BB01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:2

P M

E1.B.2

BLDG 64 - LV B - ZONE 2 - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

64-B

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"

ELECTRICAL LOWER LEVEL - B64-B(2) - NEW

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

CODED NOTES:

ALL ELECTRICAL AND LIGHTING DEVICES AND FIXTURES SHALL BE REMOVED IN THEIR ENTIRETY FROM THIS SPACE. REMOVE ALL CIRCUITING, CABLING, AND ASSOCIATED RACEWAY BACK TO THE SOURCE.

COORDINATE WITH ARCHITECTURAL PLANS FOR FLOOR PLAN ADJUSTMENTS AND REFER TO NEW WORK

ON THIS SHEET FOR NEW WORK ASSOCIATED WITH CREATING A NEW TELECOM ROOM.

M P

OFFICE

AB18D

SUPR.

AB19A

GAS

STORAGE

AB22D

WATER

SOFTENER

AB21B

STAIR #2

S2.0

DECONTAMINATION

AB22

PREP &

STERILIZATION

AB28A

STORAGE

AB23A

CORRIDOR

CB-6

ELEVATOR

LOBBY

CB-1x

ELEC

AB24

F.E.C.

AB25

ELEC

AB03

SPD

DRESSING

ROOM MALE

AB26

SPD

DRESSING

ROOM

FEMALE

AB27

ELEVATOR

PASSENGER

P-2/64

ELEVATOR

PASSENGER

P-1/64

ELEVATOR

SERVICE

S-4/64

ELEVATOR

SERVICE

S-3/64 H.A.C.

AB22A

ELEVATOR

LOBBY

CB-2

CORRIDOR

CB-5

MORT.

REFRIGERATOR

AB21A

AUTOPSY

ROOM

AB21

TOILET STAFF

AB13

STORAGE

AB21C

MECHANICAL

ROOM

AB21D

STAIR #3

S3.0

OFFICE

AB18B

H.A.C.

AB18A

OFFICE

AB18C

EMS

STORAGE

AB17

EMS. SUPR.

INT DEC.

AB19

SUPR.

AB19B

F.E.C.

AB16

SOILED LINEN

AB14

IRMS

STORAGE

AB15

MECHANICAL

ROOM

AB17A

EMS

STORAGE

AB12

LOUNGE

AB12A

OFFICE

AB12B

CLOTHING

STORAGE

AB11A

EMS

STORAGE

AB01

MEDICAL

MEDIA

AB09

OFFICE

AB09A

PMR

STORAGE

AB10

PATIENT

CLOTHING

ROOM

AB11

CORRIDOR

CB-3

OFFICE

AB09B

CORRIDOR

CB-4

ELEC

AB24A

CORRIDOR

AB18E

PATIENT

CLOTHING

ROOM

AB11

STORAGE

AB09D

MECH

AB09E

SIGN SHOP

AB12A

STORAGE

AB12A

E-401

NPAB02A

CPAB02A

B64-IDU-B-AB02A

ELECTRICAL ROOM LOCATED ON FLOOR ABOVE

REFER TO 1/E-406

DS-B64-IDU-B-AB02A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:2

P M

E1.B.3

BLDG 64 - LV B - ZONE 3 - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

64-A

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"1

ELECTRICAL LOWER LEVEL - B64-A(3) - NEW

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

CODED NOTES:

ALL ELECTRICAL AND LIGHTING DEVICES AND FIXTURES SHALL BE REMOVED IN THEIR ENTIRETY FROM THIS SPACE. REMOVE ALL CIRCUITING, CABLING, AND ASSOCIATED RACEWAY BACK TO THE SOURCE.

COORDINATE WITH ARCHITECTURAL PLANS FOR FLOOR PLAN ADJUSTMENTS AND REFER TO NEW WORK

ON THIS SHEET FOR NEW WORK ASSOCIATED WITH CREATING A NEW TELECOM ROOM.

B64-2[1] B64-D[10]

B64-2[6]

COMPUTER

STORAGE

C10A

TELECOM RM

C10A

STAIR #7

S7.0

CODING

C9D

OFFICE -

CHIEF

MEDICAL

RECORDS

AB09B

OFFICE

CB9D

TOILET

CB9A

OFFICE

CB10B

MECHANICAL

ROOM

CB10

OFFICE-

CLINICAL

PHARMACY

TECH

CB11E

OFFICE-

PHARMACIST

SUPERVISOR

CB11F

OFFICE-

ASST. CHIEF

PHARMACY

SVC

CB11D

OFFICE-

PROCUREMENT

TECH

CB11C

OFFICE

CB11B

OFFICE

CB12A

OFFICE -

HUMAN

RELATIONS

CB16

ELEC

CB14

H.A.C.

CB13

LABOR

RELATIONS

CB12

SECRETARY

PHARMACY

SVC

C11A

PHARMACY

SUPPLY

CB11

CORRIDOR

C23

CORRIDOR

CB-6

CORRIDOR

CB-5

RECORDS

CB9C

ATRIUM

BREAKROOM

AB09C 1

19' - 4"

E-401

NP6B

EP6B

EX. EP-3

EX. LP-3

DS-B64-FCU-C10B

B64-FCU-C10B

REFER TO DRAWING E1.1.6

FOR CONTINUATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:3

P M

E1.B.6

BLDG 64 - LV B - ZONE 6 - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

64-2

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"

ELECTRICAL LOWER LEVEL - B64-2(6) - NEW

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

CODED NOTES:

ALL ELECTRICAL AND LIGHTING DEVICES AND FIXTURES SHALL BE REMOVED IN THEIR ENTIRETY FROM THIS SPACE. REMOVE ALL CIRCUITING, CABLING, AND ASSOCIATED RACEWAY BACK TO THE SOURCE.

COORDINATE WITH ARCHITECTURAL PLANS FOR FLOOR PLAN ADJUSTMENTS AND REFER TO NEW WORK

ON THIS SHEET FOR NEW WORK ASSOCIATED WITH CREATING A NEW TELECOM ROOM.

E-401

EX. M

EX. EMG-1A

EX. EM

E-406

CPB10

NPB10

EX. 120/208V PNL

EX. 120/208V PNL

DS-B19-FCU-B-B10

B19-FCU-B-B10 B19-XFCU-B11

TELECOM RM

B-9B

TELECOM RM

B-10

OFFICE

B-17

OFFICE

B-17A

PAINT SUPPLY

16A

MAINTENANCE

SHOP

B-20

OFFICE

B-21

PAINT STORAGE

B-22

OFFICE

B-14

CARPENTER SHOP

B-13

PLUMBING SHOP

B-12

BATH

B-19B Room

B-19C

FEC

B-19D

A&B SECTION

B-11

OFFICE

B-8

CORRIDOR

CB-3

LOCKER ROOM

B-19

PAINT MIXING

B-16

OFFICE

B-6

OFFICE

B-2

STORAGE RM

B-9A

SUPPLY RM

B-5

WOMENS TOILET

B-3A

MENS TOILET

B-4

OFFICE

B-1

CORRIDOR

CB-1

CORRIDOR

CB-4

CORRIDOR

CB-7

CORRIDOR

CB-6

TOILET

B-19A

KITCHEN

B-18A

OFFICE

B-7

OFFICE

B-9

OFFICE

B-11A

CORRIDOR

CB-2

MECHANICAL

B-23

PLUMBING

STORAGE

B-15

CONFERENCE ROOM

B-18

CORRIDOR

CB-5

STORAGE

B-3

CORRIDOR

CB-8

ENGINEERING

STORAGE

C3-5

EQUIPMENT

B-9B

EMERGENCY ELEC

ROOM

A187

SWITCHGEAR

A188

EXTERIOR

EX. MAIN SWB

EX. ATS1-84

EX. METER

EX. 84-GEN-SWBD

EX. MAIN

BREAKER

EX. TEMP XFMR

EX. 84-GEN

SWBDH

EX. PORTABLE

GEN DOCKING

STATION

EX. 750 kVA GEN

CRTR84

ATS CRTR84

WWA188

NPTR84

EX. ATS2-84

T CRTR84

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:3

P M

E1.B.7

BLDG 19 - LV B - ZONE 7 - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"

ELECTRICAL LOWER LEVEL - B19(7) - NEW

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

2. THE ELECTRICAL CIRCUIT FROM OUTDOOR CONDENSING UNIT (ODU) TO DUCTLESS SPLIT INDOOR

UNIT (IDU) BE ROUTED WITH MECHANICAL LINSET.

CODED NOTES:

ALL ELECTRICAL AND LIGHTING DEVICES AND FIXTURES SHALL BE REMOVED IN THEIR ENTIRETY FROM THIS SPACE. REMOVE ALL CIRCUITING, CABLING, AND ASSOCIATED RACEWAY BACK TO THE SOURCE.

COORDINATE WITH ARCHITECTURAL PLANS FOR FLOOR PLAN ADJUSTMENTS AND REFER TO NEW WORK

ON THIS SHEET FOR NEW WORK ASSOCIATED WITH CREATING A NEW TELECOM ROOM.

E-401

NP164D

EP164D

B82-FCU-B-164D B82-ODU-1-251A

DS-B82-ODU-1-251A

TELECOM RM

BREAKROOM

CB6K

SPD STORAGE

BB20

BIOMED

BB16

REFRIGERATOR #1

BB09

FREEZER #1

BB09A

CORRIDOR

CB-13

FREEZER #2

BB11A

REFRIGERATOR #2

BB11

CORRIDOR

CB-12

OFFICE

C3-4

F.E.C.

C3-5

ENGINEERING

STORAGE

C3-6

DIETETICS

STORAGE

C3-7

DIETETICS

STORAGE

C3-8

CORRIDOR

C3-11

PATIENT BEDROOM

PATIENT

BATHROOM

141A

PATIENT BEDROOM

PATIENT

BATHROOM

159A

LAUNDRY

NURSE'S REPORT

RM.

161 SOILED UTILITY

NOURISH KITCHEN

CLEAN UTILITY

EQ STORAGE

DATA

ELEC CLOSET

ELEC CLOSET

STORAGE

132A

WOMENS TOILETS

170A

TOILET / THERAPY

164C

STORAGE

164B

THERAPIST OFFICE

164A

ELEVATOR MACHINE

ROOM

100A

CONFERENCE ROOM

OFFICE

WOMEN TOILET

167MEN TOILET

WAITING

C1-2

WOMENS LOCKERS

170CHILLER

FREEZER

172A

H.A.C.

OFFICE

SOILED LINEN

MEDICATION RM

TELECOM RM

DOCTOR'S OFFICE

TOILET

WARD STORAGE

LOUNGE

STORAGE

OCCUPATIONAL

ACTIVITIES

CORRIDOR

C1-6B

CORRIDOR

C1-04

CORRIDOR

C1-6A

TRASH ROOM

ALCOVE

C1-5APATIENT LOUNGE

DINING

163A

VESTIBULE

154B

STORAGE

171A

STAIR 4

S1-3

KINESIO-THERAPY

LOBBY

C1-3

CORRIDOR

C1-4

OFFICE

100E

OFFICE

100F

CLOSET

100C

ELECTRICAL

100D

ENTRY

C1-1

ALCOVE

C1-6

ALCOVE

C1-7

CORRIDOR

C1-5

NURSES STATION

CORRIDOR

C1-6

COPY ROOM

100H

ADMINISTRATION

OFFICES

ELEVATOR

P-1/82

ELEVATOR

P-2/82

ELEVATOR

P-3/82

ELEVATOR

P-4/82

M.A.S. STORAGE

C3-4

ENGINEERING

STORAGE

C3-5

OFFICE

C3-6

E.M.S. STORAGE

C3-7

EQUIPMENT

WP, G

NP164D-8

DS-B82-FCU-B-164D

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:4

P M

E1.B.9

BLDG 82 - LV B - ZONE 9 - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"1

ELECTRICAL LOWER LEVEL - B82(9) - NEW

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

CODED NOTES:

ALL ELECTRICAL AND LIGHTING DEVICES AND FIXTURES SHALL BE REMOVED IN THEIR ENTIRETY FROM THIS SPACE. REMOVE ALL CIRCUITING, CABLING, AND ASSOCIATED RACEWAY BACK TO THE SOURCE.

COORDINATE WITH ARCHITECTURAL PLANS FOR FLOOR PLAN ADJUSTMENTS AND REFER TO NEW WORK

ON THIS SHEET FOR NEW WORK ASSOCIATED WITH CREATING A NEW TELECOM ROOM.

J

E-400

B66-ACU-B-AB18HA

B66-CRAC-B-AB18HB

B66-CRAC-B-AB18HA

B66-ODU-B-AB18FA

WP, G

WP, G

B66-ODU-B-AB18FB

B66-IDU-B-AB18FA

B66-IDU-B-AB18FB

EPAB18H-4

EPAB18H-4

B66-EF-01

B66-ACU-B-AB18HB

UPS

AB18F

TELECOM RM

4A

TELECOM RM

8A

CHIEF EMS

AB20A

SECT. / RECPT.

AB20

EMS ASST CHIEF

AB20B

OFFICE

AB18

OFFICE

AB18C

OFFICE

AB18D

SUPR.

AB19B

SUPR.

AB19A

CORRIDOR

CB-4

MECH

AB18K

DATA CENTER

AB18H

OFFICE

AB18B

OFFICE

AB18C

OFFICE

6FF

EMS. SUPR. INT DEC.

AB19

SUPR.

AB19B

SUPR.

AB19A

CHIEF EMS

6KK

SECT. / RECPT.

6LL

EMS ASST CHIEF

6MM

CORRIDOR

CB-4

CORRIDOR

AB18E

OFFICE

6TT

ELEVATOR

P-2

ELEVATOR

MECHANICAL ROOM

1MECHANICAL

WOMENS TOILET

4A

WOMENS LOUNGE

LAUNDRY CHUTE

ELEVATOR

P-1

LOBBY

B

LOGISTICS SERVICE

RECEIVING OFFICE

MECHANICAL

SUPPLY &

MATERIAL

WAREHOUSE

MAIL ROOM &

OFFICE SUPPLIES

7A

EQUIPMENT

8A

CORRIDOR

6KKKKKKKKKKKKKKKK

ELEVATOR LOBBY

Y

CORRIDOR

A

STAIR 2

S2

CORRIDOR

6LLLLLLLLLLLLLLLL

ELEVATOR

ELEVATOR

RECEIVING

108CART STORAGE

STORAGE

AB18J

57a

S1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:4

P M

E1.B.11

BLDG 66 - LV B - ZONE 11 - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

1/8" = 1'-0"

ELECTRICAL LOWER LEVEL - B66(11) - NEW

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

B62[12a] B74[13]

B62[12b]

B62[12a]

B74[13]

TRANSFORMER

ROOM

LOGISTICS

SERVICE

OFFICES

MENS TOILET

TOILET

11C

OFFICE

11B

OFFICE

OFFICE

11A

OFFICE

12A

PROCUREMENT

BUSINESS

DIVISION

OFFICE

13B

OFFICE

13C

STAIR 3 /

STORAGE

13A

CONFERENCE

12B

E-401

B74-ODU-1-110A

DS-B74-ODU-1-110A

CP110A

NP110A

TELECOM RM

110A

CLEAN STORAGE

CORRIDOR

C1-1

MECHANICAL

EQUIPMENT

ROOM

LAUNDRY

B74-IDU-1-110A

DS-B74-IDU-1-110A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

A u to d e s k D o c s

/F lo ri d a

L a k e

C it y V

A /0

V

A L a k e

C it y

E H

R M

I n fr a s tr u c tu re

R

M

E P

F P

T .r v t

/2 /2

:5

:5

P M

E1.B.12

BLDG 62 - LV B - ZONE 12B - NEW LAKE CITY VAMC EHRM

INFRASTRUCTURE

UPGRADES DESIGN

LAKE CITY FL

573A4-21-700

STATION CHIEF - EDWIN BURNETT

10/25/2024 BMS KEM

100% CONSTRUCTION

DOCUMENTS

NN

0 4' 8' 16' 24'

1/8" = 1'-0"

524 Fernwood Drive, Altamonte Springs, Florida 32701 |www.rdcjpa.com| 800.362.1523

1/8" = 1'-0"1

ELECTRICAL LOWER LEVEL - B62(12B) - NEW

DRAWING NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH IN FOR FINAL LOCATION AND EXACT CONNECTION AND DISCONNECT REQUIREMENTS OF EQUIPMENT.

REFER TO EQUIPMENT AND DISCONNECT SCHEDULES ON SHEET E-801 FOR MORE INFORMATION.

CODED NOTES:

ALL ELECTRICAL AND LIGHTING DEVICES AND FIXTURES SHALL BE REMOVED IN THEIR ENTIRETY FROM THIS SPACE. REMOVE ALL CIRCUITING, CABLING, AND ASSOCIATED RACEWAY BACK TO THE SOURCE.

COORDINATE WITH ARCHITECTURAL PLANS FOR FLOOR PLAN ADJUSTMENTS AND REFER TO NEW WORK

ON THIS SHEET FOR NEW WORK ASSOCIATED WITH CREATING A NEW TELECOM ROOM.

TELECOM RM

C128

TELECOM RM

B103

TELECOM RM

251A

TELECOM RM

TELECOM RM

B06[11]

B64-A[3]

B64-A[4]

B64-B[2]

B64-2[1] B64-D[10]

B64-2[6]

B19[7]

B82[9] B82[8]

B38 [5]

MATCHLINE -

ZONE 11 TO ZONE 13

L V

L V

L V

L V

LV02 - 82

LV01 - 64

L V

L V

TELECOM RM

BH101

2.55

2.55

2.55

2.55

TELECOM RM

101A

2.04

2.55

7-9

1-3

4-6

TELECOM RM

C143A

TELECOM RM

C117TELECOM RM

TELECOM RM

BH100

TELECOM RM

4-6

1-3

7-9

S1

EX. EDP

EX. 800A ATS

EX. EGRP

EX.64-2 MAIN

SWBD

EX. MEDIUM

VOLTAGE SW

EX. 750 KVA XFMR

EX. 300 KVA XFMR

EX. 225 KW

EMERGENCY

GENERATOR

EX. GENERATOR

CNTRL PNL

CPB103

NPB103

CPBH101

NPBH101

NP251A

EP251A

EPC128

NPC128

E-406

E-406

E-402

E-402

E-406

EX. A

EX. LP-1

EX. EP-1

NP109

CP109

E-402

E-403

E-402

NPT115

EPT115 E-402

EX. 64-DP-CRH2

EX. 64-DP-LSH1

EX. 64-DP-EQH1

EX. 64-DP-CRH1

NPB85

EX. ERG-DEX. EDP-38

EPC10B

CPBB01(BASEMENT LEVEL)

NPBB01 (BASEMENT LEVEL)

CPAB02A (BASEMENT LEVEL)

NPAB02A (BASEMENT LEVEL)

CP4A(BASEMENT LEVEL)

NP4A(BASEMENT LEVEL)

EPAB18H (1ST LEVEL)

CPAB18H (1ST LEVEL)

CPA370 (3RD LEVEL)

NPA370 (3RD LEVEL)

NP464 (4TH LEVEL)

CPA464 (4TH LEVEL)

T LPNP64

T LPCR64

LPNP64

LPCR64

CRAC-A

CRAC-B

UPS-A

UPS-B

(ALL DOWN TO

BASEMENT LEVEL)

CPB103

NPB103

CP109

NP109

CPB207

NPB207

NP115 (1ST LEVEL)

EP115 (1ST LEVEL)

EP216 (2ND LEVEL)

NP216 (2ND LEVEL)

EP312 (3RD LEVEL)

NP312 (3RD LEVEL)

E-403

NP128A

CP128A

ELEC

C118

CP128A(1ST LEVEL)

NP128A(1ST LEVEL)

CP227A(2ND LEVEL)

NP227B(2ND LEVEL)

E-400

EPB85

NH-1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office…