Attachment 5a_Plans and Specifications.pdf
PDF 2 MB Posted
- Attached to
- DISA Global COLUMBUS FURNITURE Upgrade
- Solicitation number
- 832674621
- Issued by
-
Defense Information Systems Agency
About this file
This document is a set of design intent drawings for a federal facilities renovation project at the Defense Information Systems Agency (DISA) Data Center Columbus, Building 10, Section 12.
The project encompasses the demolition of existing furniture and workstations, followed by installation of new furniture systems for a command center environment. Key deliverables include removal and disposal of approximately 104 existing workstations and cubicles with associated electrical power and communication lines, and procurement and installation of new console workstations, utility cabinets, and battle captain bridge consoles arranged in a circular configuration around a raised platform. The new furniture system includes a 12-inch high raised floor platform with ABA/ADA compliant ramps (1:12 slope) and handrails serving 10 battle captain workstations, approximately 68 standard console workstations arranged in linear wings, utility cabinets with power poles and cable management systems, a movable storage console, and optional bid items including personal effects lockers and a collaboration table. Electrical work requires new power drops from the ceiling to utility cabinets with junction boxes, and new communication cable routing through pre-finished metal raceways. The contractor must verify existing conditions including column locations, disconnect and remove all abandoned electrical and communication systems, provide storage space for completion of work, and coordinate scope of electrical and communication work with DISA-Global site personnel prior to proposal preparation. Existing carpet remains in console areas but must be removed from raised platform areas, and approximately 100 damaged ceiling tiles require replacement to match existing specifications.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEFENSE INFORMATION SYSTEMS AGENCY
DATA CENTER COLUMBUS
COVER SHEET
AK
M
/M H
B
1/ 8/
C O
L_ G
-0
G-001
G
EN
ER
AL
C O
VE
R
S H
EE
T
JE
S
N
BUILDING 10
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
FY
C O
L D
IS
A
G
LO
BA
L
FU
R
N
IT
U R
E
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A
C
EN
TE
R
C O
LU
M
BU
S
D
EF
EN
SE
S U
PP
LY
C
EN
TE
R
C O
LU
M
BU
S
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
1/ 8/
FY25 DISA GLOBAL FURNITURE
SHEET LIST TABLE
SHEET
NUMBER SHEET TITLE
GENERAL
G-001 COVER SHEET
INTERIOR
ID-101 DEMOLITION FURNITURE PLAN - BLDG 10
SECTION 12
I-100 INTERIOR FURNITURE PLAN - BLDG 10
SECTION 12
DETAILS
I-500 BUILDING 10 SECTION 12 - GLOBAL
ENLARGED DETAILS
DESIGN INTENT DRAWINGS - BUILDING 10 SECTION 12
I-501 BUILDING 10 SECTION 12 - GLOBAL
ENLARGED DETAILS
I-502 BUILDING 10 SECTION 12 - GLOBAL
ENLARGED DETAILS
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
10-12-7010-12-71 10-12-6910-12-72
10-12-6810-12-73 10-12-103 10-12-104
10-12-65 10-12-66 10-12-64 10-12-67
10-12-7610-12-77 10-12-7510-12-78
10-12-7410-12-79
10-12-8210-12-83 10-12-8110-12-84
10-12-8010-12-85
10-12-8810-12-89 10-12-8710-12-90
10-12-8610-12-91 10-12-96 10-12-98
10-12-94 10-12-93
10-12-92
10-12-95 10-12-97 10-12-51 10-12-50
10-12-49
10-12-99 10-12-100 10-12-101 10-12-102
10-12-56 10-12-57 10-12-58 10-12-59
10-12-52 10-12-5510-12-53 10-12-54
10-12-29 10-12-30 10-12-27
10-12-28
10-12-15 10-12-17 10-12-18
10-12-16
10-12-11
10-12-13
10-12-14
10-12-12 10-12-20 10-12-19
10-12-21 10-12-22
10-12-24 10-12-26 10-12-25
10-12-23
10-12-07
10-12-09
10-12-10
10-12-08 10-12-03
10-12-05
10-12-06
10-12-04
10-12-61
10-12-60 10-12-63 10-12-62
10-12-48
10-12-47
10-12-01
10-12-02
10-12-45 10-12-46 10-12-43
10-12-44
10-12-41
10-12-42 10-12-39
10-12-40 10-12-37
10-12-38 10-12-35
10-12-36 10-12-33
10-12-34 10-12-31
10-12-30
REF REF REF
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
TYPICAL AT 22
WORKSTATIONS
TYPICAL AT 4
WORKSTATIONS
TYPICAL AT 22
WORKSTATIONS
TYPICAL AT 7
WORKSTATIONS
2 TYPICAL AT 4 WORKSTATIONS 2
TYPICAL AT 10
WORKSTATIONS
TYPICAL AT 8 WORKSTATIONS
TYPICAL
TYPICAL
11111
TYPICAL AT 27
WORKSTATIONS
TYPICAL
TYPICAL
DEMOLITION FURNITURE PLAN - BUILDING 10 - SECTION 12
SCALE : 3/32" = 1'-0"
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
FY
C O
L D
IS
A
G
LO
BA
L
FU
R
N
IT
U R
E
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A
C
EN
TE
R
C O
LU
M
BU
S
D
EF
EN
SE
S U
PP
LY
C
EN
TE
R
C O
LU
M
BU
S
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
1/ 8/
AK
M
/M H
B
1/ 8/
C O
L_
ID
-1
ID-101
IN
TE
R
IO
R S
D
EM
O
LI
TI
O
N F
U R
N
IT
U R
E
PL
AN
BL
D
G
- S
EC
JE
S
SCALE: NONE
KEY PLAN 1st FLOOR
C N
0 8' 16' 24'
GENERAL NOTES
1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO PREPARING AND
SUBMITTING A PROPOSAL.
2. STORAGE SPACE INSIDE THE BUILDING IS VERY LIMITED AND THE CONTRACTOR SHALL
PROVIDE STORAGE SPACE REQUIRED FOR COMPLETION OF WORK.
3. CONTRACTOR SHALL DISCONNECT ELECTRICAL POWER FROM CUBICLES THAT ARE
SCHEDULED TO BE REMOVED. REMOVE CABLE AND CONDUIT BACK TO NEAREST SOURCE.
COORDINATE LAYOUT OF NEW ELECTRICAL CABLES AND CONDUIT - EXISTING ITEMS MAY
REMAIN IN PLACE IF THEY ARE TO BE UTILIZED FOR THE NEW INSTALLATION LAYOUT.
4. CONTRACTOR SHALL CONFIRM SCOPE OF COMMUNICATION CABLE DEMOLITION WITH
DISA-GLOBAL SITE POC PRIOR TO PREPARING AND SUBMITTING A PROPOSAL.
5. NO ABANDONED ELECTRICAL OR COMMUNICATION MATERIALS (INCLUDING CONDUITS)
SHALL BE LEFT IN PLACE. ALL ABANDONED ITEMS SHALL BE REMOVED.
6. ALL EXISTING CABLES DROP FROM THE CEILING.
1. EXISTING FURNITURE TO REMAIN - PROTECT FROM DAMAGE.
2. REMOVE AND DISPOSE OF EXISTING WORKSTATIONS AND CUBICLES. REMOVE ELECTRICAL
POWER AND COMMUNICATION LINES BACK TO THE SOURCE OR NEAREST CONNECTION
POINT.
3. EQUIPMENT TO REMAIN IN PLACE. PROTECT FROM DUST AND DAMAGE.
4. COPIER TO BE REMOVED BY DISA GLOBAL.
DEMOLITION KEYNOTES:
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
TYPICAL
TYPICAL AT 27
WORKSTATIONS
TYPICAL
11111
TYPICAL
1 1 1
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
REF REF REF
EWC
LOADING PLATFORM
EWC
EWCRACK
AB
OV
E
FLOOR
R
AC
K
CO
PIE
R
10-12-7010-12-71 10-12-6910-12-72
10-12-6810-12-73
10-12-7610-12-77 10-12-7510-12-78
10-12-7410-12-79
10-12-8210-12-83 10-12-8110-12-84
10-12-8010-12-85
10-12-8810-12-89 10-12-8710-12-90
10-12-8610-12-91
10-12-94 10-12-93
10-12-92
TYPICAL AT 34
WORKSTATIONS
TYPICAL AT 34
WORKSTATIONS
6 6
6 6
TYPICAL AT 10
WORKSTATIONS
TYPICAL AT 5
PLACES ALONG
THIS ROW
TYPICAL AT 5
PLACES ALONG
THIS ROW
TYPICAL AT 5
PLACES ALONG
THIS ROW
TYPICAL AT 5
PLACES ALONG
THIS ROW
6 6
NEW FURNITURE PLAN - BUILDING 10 - SECTION 12
SCALE : 3/32" = 1'-0"
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
FY
C O
L D
IS
A
G
LO
BA
L
FU
R
N
IT
U R
E
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A
C
EN
TE
R
C O
LU
M
BU
S
D
EF
EN
SE
S U
PP
LY
C
EN
TE
R
C O
LU
M
BU
S
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
1/ 8/
AK
M
1/ 8/
C O
L_ I-1
I-101
IN
TE
R
IO
R S
N
EW
F U
R N
IT
U
R E
PL
AN
BL
D G
- S
EC
JE
S
SCALE: NONE
KEY PLAN 1st FLOOR
C N
0 8' 16' 24'
GENERAL NOTES
1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO PREPARING AND
SUBMITTING A PROPOSAL. CONTRACTOR SHALL VERIFY THAT EXISTING COLUMNS DO
NOT INTERFERE WITH NEW FURNITURE LAYOUT.
2. STORAGE SPACE INSIDE THE BUILDING IS VERY LIMITED AND THE CONTRACTOR SHALL
PROVIDE STORAGE SPACE REQUIRED FOR COMPLETION OF WORK.
3. CONTRACTOR SHALL PROVIDE AND INSTALL POWER POLES (ENCLOSED DROP FROM
EXISTING CEILING TO TOP OF UTILITY CABINET). CONFIRM NUMBER, LOCATION, AND SIZE
OF POWER POLES WITH SITE POC. SEE KEYNOTES AND PLANS FOR UTILITY CABINETS.
4. EXISTING CARPET IS IN PLACE - AND SHALL REMAIN - AT AREAS WHERE NEW CONSOLES
ARE TO BE INSTALLED.
5. EXISTING CARPET IS IN PLACE - AND SHALL BE REMOVED BY CONTRACTOR - AT AREAS
WHERE NEW RAISED PLATFORM AND RAMPS ARE TO BE INSTALLED (AT BATTLE CAPTAIN
STATIONS).
6. CONTRACTOR SHALL RUN NEW ELECTRICAL POWER TO THE THE UTILITY CABINETS.
INSTALL J-BOX IN UTILITY CABINETS. ELECTRICAL SUBCONTRACTOR SHALL PERFORM
FINAL CONNECTION OF POWER WHIPS (FROM NEW WORKSTATIONS) TO NEW J-BOXES IN
UTILITY CABINETS.
7. CONTRACTOR SHALL VERIFY SCOPE OF COMMUNICATION CABLE WORK WITH
DISA-GLOBAL SITE POC PRIOR TO PREPARING AND SUBMITTING A PROPOSAL.
8. ALL NEW ELECTRICAL AND COMMUNICATION CABLES SHALL BE ROUTED FROM ABOVE
THE CEILING.
9. CONTRACTOR SHALL REPLACE CEILING TILES THAT ARE IN POOR CONDITION - OR
DAMAGED DUE TO DEMOLITION/INSTALLATION OPERATIONS. NEW CEILING TILES SHALL
MATCH EXISTING TILES IN COLOR, TEXTURE, AND DETAILING. FOR PURPOSES OF
PREPARING A PROPOSAL - CONTRACTOR SHALL ASSUME 100 CEILING TILES ARE TO BE
REPLACED.
1. EXISTING FURNITURE TO REMAIN - PROTECT FROM DAMAGE.
2. TYPICAL CONSOLES - PURCHASE AND INSTALL NEW WORKSTATION/CONSOLES AS PER
DETAIL 1/I-500.
3. TYPICAL BATTLE CAPTAIN WORKSTATION - PURCHASE AND INSTALL NEW WORKSTATIONS
AS PER DETAILS 1/I-501 AND 1/I-502.
4. 12" HIGH RAISED FLOOR SYSTEM PLATFORM, INCLUDING RAMPS AND HANDRAILS -
PURCHASE AND INSTALL AS PER DETAIL 2/I-501.
5. OPTIONAL BID ITEM #1. LOCKERS OR STORAGE CABINETS FOR PERSONAL EFFECTS -
CONFIRM WITH DISA GLOBAL POC.
6. UTILITY CABINET AT END OF CONSOLE WING, WITH POWER POLES (DROP FROM CEILING TO
UTILITY CABINET) - PURCHASE AND INSTALL NEW CABINETS AS PER DETAIL 2/I-500.
7. UTILITY CABINET BETWEEN CONSOLE WING AND CURVED BATTLE CAPTAIN WORKSTATION,
WITH POWER POLES (DROP FROM CEILING) AND CABLE MANAGEMENT SYSTEM INSIDE
CONNECTOR BLOCK - PURCHASE AND INSTALL NEW CABINET AS PER DETAIL 3/I-500.
8. EXISTING EQUIPMENT - PROTECT FROM DUST AND DAMAGE.
9. COPIER TO BE INSTALLED BY DISA GLOBAL.
10. OPTIONAL BID ITEM #2. COLLABORATION TABLE (3'x6') AND 8 CHAIRS - CONFIRM WITH DISA
GLOBAL POC.
11. RAMP FROM EXISTING FLOOR TO RAISED PLATFORM AT BATTLE CAPTAIN WORKSTATIONS.
SLOPE AT 1:12. PROVIDE WITH HANDRAILS. COMPLY WITH ABA REQUIREMENTS. PROVIDE
AND INSTALL RAMP AS PER DETAILS 1/I-501 AND 2/I-501.
12. EXISTING PAINTED STEEL TUBE STRUCTURAL COLUMNS. APPROXIMATE SIZE = 6"x6". FIELD
VERIFY LAYOUT AND LOCATIONS OF ALL COLUMNS.
13. MOVABLE STORAGE CONSOLE. PROVIDE AND INSTALL NEW STORAGE CONSOLE AS PER
DETAIL 2/I-502.
NEW FURNITURE KEYNOTES:
2' -5
SERVICE PANEL WITH SLAT WALL. PROVIDE
TACKABLE ACOUSTICAL PANEL WHEN EXPOSED.
(4) SINGLE MONITOR ARMS, SLAT WALL MOUNTED
CANILEVERED WORK SURFACE, TYPICAL
END PANEL. PROVIDE WITH TACKABLE ACOUSTICAL
PANEL WHERE EXPOSED
END PANELS. PROVIDE WITH TACKABLE
ACOUSTICAL PANEL WHEN EXPOSED.
MOBILE PEDESTAL BOX/FILE
EXISTING FINISHED FLOOR
STORAGE CABINET
ACCESS DOORS WITH VENTING
ADJACENT CONSOLE (MIRRORED CONFIGURATION) -
WHERE OCCURS
MIRRORED CONSOLE - WHERE OCCURS
BACK PANEL. PROVIDE WITH TACKABLE ACOUSTICAL
PANEL WHERE EXPOSED. PROVIDE WITH SLAT WALL
WHERE MONITORS OCCUR.
(4) SINGLE MONITOR ARMS, SLAT WALL MOUNTED.
PROVIDE PROPER SEPARATION BETWEEN MONITORS
BASED ON CLASSIFICATIONS OF DATA DISPLAYED.
CANILEVERED WORK SURFACE, TYPICAL
STORAGE CABINET
ACCESS PANEL TO CABLE TRAY (HATCHED AREA).
PROVIDE WITH 3 WIRE MANAGEMENT GROMMETS.
MOBILE PEDESTAL BOX/FILE
END PANELS
BACK PANEL WITH SLAT WALL AT MONITORS
(4) SINGLE MONITOR ARMS, SLAT WALL MOUNTED
CANILEVERED WORK SURFACE, TYPICAL
STORAGE CABINET WITH OPEN STORAGE (WITH
ADJUSTABLE SHELF) AND DRAWERS (BOX/BOX/FILE)
WIRE MESH CABLE TRAY
REMOVABLE PANEL TO ACCESS TO CABLE TRAY
6'-0"
4' -4
"2' -1
0"
10 1/2" 2'-0"
3' -6
2' -5
1'
-1
OPEN
OPEN
DRAWER
DRAWER
DRAWER
FILE
DRAWER
DRAWER
FILE
BUILT-IN PC CABINET WITH VENTED ACCESS DOORS
EXISTING CARPET OVER CONCRETE SLAB ON GRADE
EXISTING CEILING GRID AND ACOUSTICAL LAY-IN TILES
9' -0
EXISTING CEILING GRID AND ACOUSTICAL LAY-IN TILES
9' -0
2"
(F
IE
LD
V
ER
IF
Y)
(F
IE
LD
V
ER
IF
Y)
1' -5
/2
UTILITY CABINET WITH TOP TO MATCH WORK
SURFACE OF CONSOLE UNITS
ADJACENT CONSOLE (END UNIT). REFER TO
PLAN FOR CONFIGURATION (SINGLE UNIT VS
BACK TO BACK UNITS). REFER TO 1/I-500.
AREA OF REMOVEABLE WORK SURFACE PANEL -
ALLOWING ACCESS TO CABLE TRAY BELOW
CANILEVERED WORK SURFACE
PRE-FINISHED METAL RACEWAY (FROM UTILITY CABINET
TO CEILING) - FOR ELECTRICAL AND COMMUNICATION
CABLES. RACEWAY SHOWN IS FOR SCHEMATIC
PURPOSES ONLY. CONFIRM SIZE, NUMBER, AND
CONFIGURATION OF RACEWAY(S) WITH UTILITY
REQUIREMENTS OF EACH UTILITY CABINET LOCATION.
UTILIZE INTERIOR OF UTILITY CABINET FOR LOCATION OF
JUNCTION BOXES FOR ELECTRICAL FEEDS TO CONSOLE
UNITS.
4'-6"
2' -0
UTILITY CABINET TOP TO MATCH WORK TOP
OF CONSOLE UNITS
END PANEL. MATCH PANELS OF CONSOLE UNITS.
EXISTING FINISHED FLOOR
REMOVABLE PANELS (TO PROVIDE ACCESS
TO INTERIOR OF UTILITY CABINET)
EXISTING CEILING GRID AND ACOUSTICAL LAY-IN TILES
PRE-FINISHED METAL RACEWAY (FROM UTILITY
CABINET TO CEILING) - FOR ELECTRICAL AND
COMMUNICATION CABLES.
BACK PANEL OF CONSOLE UNIT BEYOND. REFER TO B/1-500.
OPENING (AT REAR OF UTILITY CABINET) TO
CABLE TRAY AREA OF CONSOLE UNIT BEYOND
2' -5
9' -0
9' -0
END PANEL OF UTILITY CABINET. MATCH PANELS
OF CONSOLE UNITS.
EXISTING FINISHED FLOOR
TYPICAL CONSOLE UNIT. REFER TO A/I-500.
EXISTING CEILING GRID AND ACOUSTICAL LAY-IN TILES
PRE-FINISHED METAL RACEWAY (FROM UTILITY
CABINET TO CEILING) - FOR ELECTRICAL AND
COMMUNICATION CABLES.
BACK PANEL OF ADJACENT CONSOLE UNIT
CABLE TRAY AREA OF CONSOLE UNIT - WITH
OPENING INTO UTILITY CABINET FOR
ELECTRICAL AND COMMUNICATION CABLES
6' -7
(F
IE
LD
V
ER
IF
Y)
(F
IE
LD
V
ER
IF
Y)
(F
IE
LD
V
ER
IF
Y)
UTILITY CABINET WITH TOP TO MATCH WORK
SURFACE OF CONSOLE UNITS
CENTERLINE OF LAYOUT FOR BATTLE CAPTAIN
STATIONS. SEE 1/I-501.
PRE-FINISHED METAL RACEWAY (FROM UTILITY CABINET
TO CEILING) - FOR ELECTRICAL AND COMMUNICATION
CABLES. RACEWAY SHOWN IS FOR SCHEMATIC
PURPOSES ONLY. CONFIRM SIZE, NUMBER, AND
CONFIGURATION OF RACEWAY(S) WITH UTILITY
REQUIREMENTS OF UTILITY CABINET. UTILIZE INTERIOR
OF UTILITY CABINET FOR LOCATION OF JUNCTION BOXES
FOR ELECTRICAL FEEDS TO CONSOLE UNITS AND BATTLE
CAPTAIN STATIONS.
THE RACEWAYS AT THIS UTILITY CABINET SERVE BOTH
CONSOLES AND BATTLE CAPTAIN STATIONS.
UTILITY CABINET TOP TO MATCH WORK TOP
OF CONSOLE UNITS
BATTLE CAPTAIN BRIDGE CONSOLE ADJACENT
TO UTILITY CABINET. REFER TO B/I-502.
NEW RAISED FLOOR SYSTEM UNDER BATTLE
CAPTAIN STATIONS. UTILITIES ROUTED FROM
RACEWAY TO UNDER RAISED FLOOR.
REMOVABLE PANELS (TO PROVIDE ACCESS
TO INTERIOR OF UTILITY CABINET)
EXISTING CEILING GRID AND ACOUSTICAL LAY-IN TILES
PRE-FINISHED METAL RACEWAY (FROM UTILITY
CABINET TO CEILING) - FOR ELECTRICAL AND
COMMUNICATION CABLES.
CONSOLE UNIT ADJACENT TO UTILITY CABINET.
REFER TO B/1-500.
OPENING (AT SIDE OF UTILITY CABINET) TO
CABLE TRAY AREA OF CONSOLE UNIT
2' -5
9' -0
CONSOLE UNITS (END UNITS) ADJACENT TO
UTILITY CABINET. REFER TO 1/I-500.
BATTLE CAPTAIN BRIDGE CONSOLE. REFER TO 1/I-502.
2'-6"
7' -8
/2
CONFIRM DIMENSION
WITH DETAILING OF
BATTLE CAPTAIN
STATION
CABLE TRAY AREA OF CONSOLE UNIT - WITH
OPENING INTO UTILITY CABINET FOR
ELECTRICAL AND COMMUNICATION CABLES
EXISTING FINISHED FLOOR
ELECTRICAL ROUTING NOTES:
1. ELECTRICAL SERVICE WILL DROP FROM THE CEILING TO FEED ALL WORKSTATIONS.
2. PRE-FINISHED METAL RACEWAYS WILL ENCLOSE THE UTILITIES FROM THE CEILING TO THE UTILITY CABINETS*.
3. POWER FOR CONSOLE UNITS WILL ROUTE THROUGH THE CABLE TRAY CAVITY THAT IS INTEGRAL TO THE CONSOLE
WORKSTATIONS.
4. POWER FOR BATTLE CAPTAIN STATIONS WILL BE ROUTED UNDER THE NEW RAISED FLOOR STRUCTURE WHICH IS THE BASE FOR
THE BATTLE CAPTAIN STATIONS.
5. ONE 20-AMP ELECTRICAL CIRCUIT WILL SERVE 2 WORKSTATIONS. POWER-HARNESSES (BUILT INTO THE CONSOLE UNITS) WILL PROVIDE POWER FOR UP TO 8 WORKSTATIONS (4 CIRCUITS, 8-WIRE, 20 AMP POWER-HARNESS).
6. AFTER DISCUSSIONS WITH THE ELECTRICAL CONTRACTOR - IT MAY BE POSSIBLE TO MOUNT ELECTRICAL JUNCTION BOXES INSIDE THE UTILITY CABINETS AS THE TERMINATION OF THE BUILDING ELECTRICAL POWER SUPPLY FOR THESE POWER-HARNESS
CONNECTIONS.
* SEE PLAN FOR UTILITY CABINET LOCATIONS.
RACEWAY NOTES:
1. RACEWAYS ARE BASED ON 14" X 4" (APPROXIMATE SIZE) PRE-FINISHED METAL UNITS FROM LEGRAND - OTHER MANUFACTURERS
MAY BE USED IF APPROVED BY DISA'S SITE POC (POINT OF CONTACT).
2. BASIS OF DESIGN LEGRAND / WIREMOLD "VISTA ARCHITECTURAL COLUMNS". UNITS ARE AVAILABLE WITH ROUND OR SQUARE END
CAPS.
3. CONSIDER SETTING DUPLEX OUTLETS INTO THE FACE OF THE RACEWAY AT 4" ABOVE THE UTILITY CABINET WORK SURFACE - FOR USE AS CONVENIENCE OUTLETS (THESE SHOULD BE A SEPARATE CIRCUIT - FROM FEEDS FOE WORKSTATIONS).
4. RACEWAYS WILL ALSO BE UTILIZED BY COMMUNICATION CABLES - A MIX OF CLASSIFIED AND UNCLASSIFIED NETWORKS. IT IS ANTICIPATED THAT THE NETWORKS WILL CONSIST OF A MIX OF CAT6 AND DUPLEX FIBER OPTIC CABLES.
5. THE NUMBER OF COMMUNICATION NETWORKS AND TYPES OF CABLES SHALL BE CONFIRMED WITH DISA'S SITE POC.
1' -0
8'
-0 "6'
-7
(F
IE
LD
V
ER
IF
Y)
(F
IE
LD
V
ER
IF
Y)
(F
IE
LD
V
ER
IF
Y)
2"
LINE OF RISED PLATFORM BELOW. SEE 2/I-501.
AK
S/
M H
B
1/ 8/
C O
L_ G
LO
BA
L_ I-5
I-500
IN
TE
R
IO
R S
EN
LA
R G
ED
F
U R
N
IT
U R
E D
ET
AI
LS
BL
D
G
- S
EC
JE
S
I-500
B I-500
A I-500
A I-500
TYPICAL CONSOLE (WORKSTATION) - PLAN
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
TYPICAL CONSOLE - ELEVATION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
TYPICAL CONSOLE - SECTION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
B I-500
I-500
C I-500
UTILITY CABINET AT CONSOLE - PLAN
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
UTILITY CABINET - SIDE ELEVATION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
D I-500
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
FY
C O
L D
IS
A
G
LO
BA
L
FU
R
N
IT
U R
E
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A
C
EN
TE
R
C O
LU
M
BU
S
D
EF
EN
SE
S U
PP
LY
C
EN
TE
R
C O
LU
M
BU
S
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
1/ 8/
I-500
UTILITY CABINET AT BATTLE CAPTION STATION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
E I-500
UTILITY CABINET - END ELEVATION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
E I-500
D I-500
UTILITY CABINET - FRONT ELEVATION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
C I-500
16°
32°
32°
10°
10'-6" 3'-6"
2'-6"
'-8
'-0
20'-0"
'-0
'-0
'-0
(FIELD VERIFY)
(F
IE
LD
V
ER
IF
Y)
'-6
6'
-2
CENTER LINE
OF PLATFORM
C
EN
TE
R
L
IN
E O
F
PL
AT
FO
R M
13'-2 1/2" 6'-9 1/2"
'-0
(1 2"
H
IG
H R
AI
SE
D P
LA
TF
O R
M W
IT
H
S
IX
TE
EN
' R
AI
SE
D F
LO
O
R T
IL
E
M O
D U
LE
S
FR
O
M R
AM
P
TO
R
AM
P)
(R
AM
P W
IT
H
S
LO
PE
O
F 1:
ABA/ADA COMPLIANT RAMP (2'x2' RAISED
FLOOR TILES) AND HANDRAILS
(FIELD VERIFY) (FIELD VERIFY)
(F
IE
LD
V
ER
IF
Y) (F
IE
LD
V
ER
IF
Y)
(F
IE
LD
V
ER
IF
Y)
(R
AM
P W
IT
H
S
LO
PE
O
F 1:
ABA/ADA COMPLIANT RAMP (2'x2' RAISED
FLOOR TILES) AND HANDRAILS
RAISED FLOOR PLATFORM AT BATTLE
CAPTAIN STATIONS - SEE 2/I-501
EXISTING STEEL TUBE COLUMNS (TYPICAL
AT 6 PLACES SHOWN ON THIS PLAN). FIELD
VERIFY COLUMN LAYOUT AND DIMENSIONS.
'-0
'-0
1' -1
/1 6"
'-0
/1
6"
'-0
/1 6"
1' -1
/1 6"
28'-4"
12'-2" 4'-0" 12'-2"
(1 2"
H
IG
H R
AI
SE
D P
LA
TF
O R
M W
IT
H
S
IX
TE
EN
' R
AI
SE
D F
LO
O
R T
IL
E
M O
D U
LE
S
FR
O
M R
AM
P
TO
R
AM
P)
(R
AM
P W
IT
H
S
LO
PE
O
F 1:
ABA/ADA COMPLIANT RAMP (2'x2' RAISED FLOOR TILES) AND HANDRAILS. PROVIDE
DIAGONAL BRACING - TO ENSURE LATERAL STIFFNESS.
(R
AM
P W
IT
H
S
LO
PE
O
F 1:
ABA/ADA COMPLIANT RAMP (2'x2' RAISED
FLOOR TILES) AND HADRAILS
RAISED FLOOR PLATFORM AT BATTLE CAPTAIN STATIONS (2'x2' RAISED FLOOR TILES
- SET AT 12" ABOVE EXISTING CONCRETE SLAB). PROVIDE DIAGONAL BRACING FROM
TOP OF PEDESTALS (RAISED FLOOR SYSTEM SUPPORT POSTS) TO CONCRETE
FLOOR - TO ENSURE LATERAL STIFFNESS.
CENTER LINE
OF PLATFORM
C
EN
TE
R
L
IN
E O
F
PL
AT
FO
R M
AT PERIMETER OF PLATFORM AND RAMPS - INSTALL PRE-FINISHED METAL FASCIA
(CLOSURE) PLATE (FROM TOP OF RAISED FLOOR TILES TO EXISTING CONCRETE
FLOOR SLAB). INSTALL PRE-FINISHED TRIM ANGLE TO COVER TRANSITION WHERE
FASCIA PLATE MEETS RAISED FLOOR TILES. INSTALL ANGLES (SECURED TO
EXISTING CONCRETE FLOOR SLAB) TO PROVIDE STABILITY AND ANCHORAGE FOR
BOTTOM EDGE OF FASCIA PLATE.
AT RAMP TERMINATION - INSTALL RAMP SHOE (WEDGE BY MANUFACTURER)
TO ENSURE SMOOTH ABA/ADA COMPLIANT TRANSITION FROM LAST RAISED
FLOOR TILE TO FINISHED FLOOR SURFACE.
REMOVE EXISTING CARPET FROM AREA UNDER NEW RAISED FLOOR PLATFORM
AND RAMP - TO PROVIDE SECURE ATTACHMENT OF PEDESTALS (SUPPORT
POSTS) TO EXISTING CONCRETE FLOOR SLAB.
WHERE RAMP MEETS RAISED PLATFORM -
INSTALL THRESHOLD (BY MANUFACTURER) TO
ENSURE SMOOTH ABA/ADA COMPLIANT
TRANSITION FROM TOP END OF RAMP TO
RAISED FLOOR TILE (OF LEVEL PLATFORM).
EXISTING STEEL TUBE COLUMNS (TYPICAL
AT 6 PLACES SHOWN ON THIS PLAN). FIELD
VERIFY COLUMN LAYOUT AND DIMENSIONS.
ENSURE CLEARANCE
BETWEEN PLATFORM
AND THIS COLUMN
THIS EXISTING COLUMN PENETRATES THE
PLATFORM. RAISED FLOOR TILES TO BE
FITTED AROUND COLUMN - PROVIDE
ADDITIONAL SUPPORT STRUCTURE AS
REQUIRED.
DASHED LINE INDICATES LIMITS OF BATTLE
CAPTAIN BRIDGE CONSOLE
R
AM
P
U P
P
P
U P
R
AM
P
AM
P
FACE OF BATTLE CAPTAIN
BRIDGE CONSOLE
FACE OF RAISED PLATFORM
1' -6
ADJACENT UTILITY CABINET
WITH UTILITY RACEWAYS . SEE
3/I-500.
ADJACENT CONSOLE UNITS.
SEE 1/I-500.
BATTLE
CAPTAIN
BRIDGE
CONSOLE
2"
FACE OF BATTLE CAPTAIN
BRIDGE CONSOLE
FACE OF RAISED FLOOR
PLATFORM BELOW
FACE OF GALLERY
BATTLE CAPTAIN BRIDGE
CONSOLE - SEE 1/A-502
(TYPICAL AT 10 WORKSTATIONS)
MOVABLE STORAGE CONSOLE -
SEE 2/A-502
R14 '-2
6' -2
FI
EL
D
V
ER
IF
Y
AD
JU
ST
A S
N
EE
D
ED
13'-2 1/2"
FIELD VERIFY
- ADJUST AS
NEEDED
AK
S/
M H
B
1/ 8/
C O
L_ G
LO
BA
L_ I-5
I-501
IN
TE
R
IO
R S
EN
LA
R G
ED
F
U R
N
IT
U R
E D
ET
AI
LS
BL
D
G
- S
EC
JE
S
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
FY
C O
L D
IS
A
G
LO
BA
L
FU
R
N
IT
U R
E
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A
C
EN
TE
R
C O
LU
M
BU
S
D
EF
EN
SE
S U
PP
LY
C
EN
TE
R
C O
LU
M
BU
S
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
1/ 8/
I-501
BATTLE CAPTAIN STATIONS - PLAN
SCALE : 1/4"= 1'-0" 0 2' 4' 8'
I-501
BATTLE CAPTAIN PLATFORM - PLAN
SCALE : 1/4"= 1'-0" 0 2' 4' 8'
14'-0"
3'-6"
10'-6"
5' -9
/2
7' -8
/2
6 1/2"
CANILEVERED WORK SURFACE, TYPICAL
GALLERY TRANSACTION TOP - 8" WIDE
ADJACENT CONSOLE WHERE OCCURS
UPPER GALLERY WALL (+/- 4.5"
THICK - BELOW TRANSACTION
TOP). SLAT WALL AT AREA
BEHIND MONITORS.
(4) SINGLE MONITOR ARMS, SLAT WALL MOUNTED.
PROVIDE PROPER SEPARATION BETWEEN MONITORS
BASED ON CLASSIFICATIONS OF DATA DISPLAYED.
ACCESS PANEL TO CABLE TRAY (HATCHED AREA).
PROVIDE WITH 4 WIRE MANAGEMENT GROMMETS.
(A
PP
R O
XI
M
AT
E
LI
N
EA
R
D
IM
EN
SI
O N
AT
G
AL
LE
R Y
PA
N
EL
FLAT SEGMENTED
PANELS REQUIRED FOR
SLAT WALL ATTACHMENT
RAISED PLATFORM AT BATTLE CAPTAIN STATIONS
ADJACENT CONSOLE WHERE OCCURS
FACE OF GALLERY
PANEL (BASED ON
ARC LAYOUT)
CENTER OF BATTLE
CAPTAIN STATION
LAYOUT AND CENTER
OF RAISED PLATFORM
ALL ELECTRICAL AND COMMUNICATION CABLES SHALL BE ROUTED TO
BATTLE CAPTAIN BRIDGE CONSOLE UNITS FROM UNDER THE RAISED FLOOR
PLATFORM. CABLES SHALL BE ROUTED FROM ABOVE THE CEILING AND
THROUGH THE UTILITY CABINETS BEFORE BEING ROUTED UNDER THE
RAISED FLOOR PLATFORM.
2' -5
ADJACENT CONSOLE WHERE OCCURS
EXISTING CEILING GRID AND ACOUSTICAL
LAY-IN TILES
9' -0
(F
IE
LD
V
ER
IF
Y)
1' -1
UPPER GALLERY PANEL WITH PLASTIC LAMINATE
VENEER
(4) MONITORS, BEHIND UPPER GALLERY PANEL
FEATURE REVEAL BAND
NEW RAISED FLOOR PLATFORM
BUILT-IN PC CABINET BEHIND GALLERY PANEL
EXISTING CONCRETE SLAB ON GRADE (REMOVE
EXISTING CARPET UNDER AREA OF NEW RAISED
FLOOR PLATFORM
GALLERY TRANSACTION TOP - 8" WIDE
CABLE TRAY BEHIND GALLERY PANEL
LOWER GALLERY PANEL WITH PLASTIC LAMINATE
VENEER
1' -0
BACK PANEL WITH SLAT WALL AT MONITORS
(4) SINGLE MONITOR ARMS, SLAT WALL MOUNTED
CANILEVERED WORK SURFACE WITH PLASTIC
LAMINATE VENEER
NEW RAISED FLOOR PLATFORM
WIRE MESH CABLE TRAY
REMOVABLE PANEL TO ACCESS TO CABLE TRAY
1'-6" 2'-0"
3' -6
2' -5
/2
BUILT-IN PC CABINET
EXISTING CONCRETE SLAB ON GRADE (REMOVE
EXISTING CARPET UNDER AREA OF NEW RAISED
FLOOR PLATFORM
EXISTING CEILING GRID AND ACOUSTICAL
LAY-IN TILES
9' -0
(F
IE
LD
V
ER
IF
Y)
1' -5
/2
1' -0
3'-6"2"
GALLERY TRANSACTION TOP - 8" WIDE
1/
2"
VENTED ACCESS DOORS
UPPER GALLERY PANEL WITH
PLASTIC LAMINATE VENEER
FEATURE REVEAL
LOWER GALLERY PANEL
WITH PLASTIC LAMINATE
VENEER
PRE-FINISHED METAL SKIRT
(CLOSURE PANEL AT RAISED
PLATFORM PERIMETER)
4" TALL VINYL COVE BASE
EXISTING CARPET
2' -5
ADJACENT CONSOLE WHERE OCCURS
EXISTING CEILING GRID AND ACOUSTICAL
LAY-IN TILES
9' -0
(F
IE
LD
V
ER
IF
Y)
1' -1
BACK PANEL WITH SLAT WALL AT MONITORS
(4) SINGLE MONITOR ARMS, SLAT WALL MOUNTED
CANILEVERED WORK SURFACE, TYPICAL
NEW RAISED FLOOR PLATFORM
BUILT-IN PC CABINET WITH VENTED ACCESS
DOORS
EXISTING CONCRETE SLAB ON GRADE (REMOVE
EXISTING CARPET UNDER AREA OF NEW RAISED
FLOOR PLATFORM
GALLERY TRANSACTION TOP - 8" WIDE
END PANEL
1' -0
LINE OF PARTITIONS BELOW
1/4" x 2" ROLLED ALUMINUM BAR EDGE TRIM
STORAGE CONSOLE UNIT - BUILT IN 2-PIECES TO ALLOW
FOR REMOVAL VIA RAMP IF REQUIRED. PROVIDE
ATTACHMENT METHOD TO SECURE 2 SECTIONS INTO A
"SINGLE UNIT" FOR TYPICAL OPERATIONAL USAGE - YET
ALLOW FOR QUICK SEPARATION WHEN REQUIRED.
LINE OF ADJUSTABLE SHELF BELOW
1/4" TEMPERED GLASS TOP (BACK-PAINTED WHITE)
SET OVER SUBSTRATE.
LINE OF GLASS TOP AND BASE BELOW
LINE OF THEORETICAL RADIUS (FOR
PARTITION LAYOUT
2'- 6"
1'- 3"
1'- 3"
ALL EXPOSED SURFACES (NOT COVERED WITH GLASS OR
EDGE TRIM) TO BE PLASTIC LAMINATE VENEER.
BOTTOM OF STORAGE CONSOLE
1/4" x 2" ROLLED ALUMINUM BAR EDGE TRIM
STORAGE CONSOLE UNIT - BUILT IN 2-PIECES TO ALLOW
FOR REMOVAL VIA RAMP IF REQUIRED. PROVIDE
ATTACHMENT METHOD TO SECURE 2 SECTIONS INTO A
"SINGLE UNIT" FOR TYPICAL OPERATIONAL USAGE - YET
ALLOW FOR QUICK SEPARATION WHEN REQUIRED.
GLAS TOP. 1/4" TEMPERED GLASS TOP
(BACK-PAINTED WHITE) SET OVER SUBSTRATE.
NEW RAISED FLOOR PLATFORM
EXISTING CONCRETE SLAB ON GRADE (REMOVE
EXISTING CARPET UNDER AREA OF NEW RAISED
FLOOR PLATFORM
CASTER WHEELS (8 TOTAL) - 2 LOCKING WHEELS PER
EACH INDIVIDUAL HALF OF CONSOLE UNIT
BACK PARTITION (FIXED PANEL)
SIDE PARTITION (FIXED PANEL)
ADJUSTABLE SHELF
"QUICK-RELEASE" LATCHES
(OR THRU-BOLT
MECHANISM)TO SECURE 2
HALVES TOGETHER
3' -0
ALL EXPOSED SURFACES (NOT COVERED WITH GLASS OR
EDGE TRIM) TO BE PLASTIC LAMINATE VENEER.
FINISHES TO MATCH BATTLE CAPTAIN STATIONS.
AK
S/
M H
B
1/ 8/
C O
L_ G
LO
BA
L_ I-5
I-502
IN
TE
R
IO
R S
EN
LA
R G
ED
F
U R
N
IT
U R
E D
ET
AI
LS
BL
D
G
- S
EC
JE
S
A I-502
I-502
TYPICAL BATTLE CAPTAIN BRIDGE CONSOLE - PLAN
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
BATTLE CAPTAIN CONSOLE - ELEVATION FROM GALLERY
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
A I-502
I-500
STORAGE CONSOLE --- PLAN
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
SHEET
IDENTIFICATION
D
ES
IG
N
B Y:
D R
AW
N
B Y:
SU
BM
IT
TE
D B
Y:
PL
O
T
SC
AL
E:
SI
ZE
AN
SI
D
C H
EC
KE
D B
Y:
PL
O
T D
AT
E:
FI
LE
N
AM
E:
SU
BM
IT
TA
L D
AT
E:
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
FI
LE
N U
M
BE
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
:M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E:
AP
PR
B
C
D
1 2 3 4 5
1 2 3 4 5
Defense Information Systems Agency A Combat Support Agency
A
B
D
C
H C
FA
C
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
A
FY
C O
L D
IS
A
G
LO
BA
L
FU
R
N
IT
U R
E
N /A
N /A
N /A
N /A
N
/A AS
S H
O W
N
BU
IL
D
IN
G
D
AT
A
C
EN
TE
R
C O
LU
M
BU
S
D
EF
EN
SE
S U
PP
LY
C
EN
TE
R
C O
LU
M
BU
S
2 S
. W
ILLO
W
DR
. ST
E. 2
G
R
EE
N W
O O
D V
IL
LA
G E, C O
LO
R
AD
O
1/ 8/
D I-502
STORAGE CONSOLE - ELEVATION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
C I-502
BATTLE CAPTAIN CONSOLE - SECTION
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
B I-502
BATTLE CAPTAIN CONSOLE - ELEVATION FROM PLATFORM
SCALE : 3/8"= 1'-0" 0 2' 4' 6'
C I-502
A I-502
C I-502
B I-502
B I-502
B I-502
D I-502
ITEMS WITH COST CONSIDERATIONS
1. POSSIBLE COST SAVING. UTILITY CABINETS AT ENDS OF WORKSTATIONS (DETAIL 2/I-501) MAY POSSIBLY BE REPLACED BY FULL-HEIGHT PRE-FINISHED METAL RACEWAY UNITS (FROM CEILING TO FLOOR). COORDINATE RACEWAY CROSS SECTION SIZE WITH CABLE MINIMUM BEND RADIUS AND DETAILING OF CONSOLE UNITS. IF THIS OPTION IS CHOSEN - ELECTRICAL J-BOXES (POWER FOR WORKSTATIONS) SHALL BE INSTALLED ABOVE THE CEILING, AND THE ELECTRICAL WHIPS (OF THE CONSOLE UNITS) WILL NEED TO BE LONGER TO REACH THE J-BOXES ABOVE THE CEILING. ENSURE THE WHIPS ARE DETAILED TO BE COMPLIANT WITH ELECTRICAL CODE REQUIREMENTS. THE EXTENDED LENGTH OF THESE WHIPS MAY NOT BE ALLOWED BY CODE.
2. POSSIBLE COST SAVING. THE 1/4" TEMPERED GLASS TRANSACTION CAP AT THE BATTLE CAPTAIN BRIDGE CONSOLES - AND THE 1/4" GLASS TOP OF THE STORAGE CONSOLE, COULD BE REPLACED BY OTHER MATERIALS. CONSIDER REPLACING GLASS WITH STONE (GRANITE, MARBLE), SYNTHETIC STONE (QUARTZ MAN-MADE CONGLOMERATE), SOLID-SURFACE MATERIAL ("CORIAN" OR
EQUAL), SOLID WOOD, OR OTHER MATERIAL AS RECOMMENDED BY CONSOLE FABRICATOR.
3. POSSIBLE COST SAVING. THE BATTLE CAPTAIN BRIDGE CONSOLES ARE DESIGNED WITH A CIRCULAR FRONT PANEL, IT MAY BE LESS EXPENSIVE (MAYBE NOT) TO CONSTRUCT THESE UNITS WITH SEGMENTED FRONT PANELS - WHILE KEEPING THE GLASS
TRANSACTION CAP AS A CIRCULAR ITEM.
4. POSSIBLE COST SAVING. THIS SET OF PLANS HAS OMITTED REMOVABLE PANELS FROM THE GALLERY WALL OF THE BATTLE CAPTAIN BRIDGE CONSOLES (REMOVABLE PANELS ARE STILL PROVIDED UNDER THE DESKTOP OF THE CONSOLES). ON PREVIOUS PROJECTS - THE GALLERY PANEL OF THE BATTLE CAPTAIN BRIDGE CONSOLES WERE DETAILED WITH REMOVABLE PANELS.
PROVIDING FIXED FRONT PANELS WILL PROVIDE A COST SAVING - BUT ONLY IF IT IS ACCEPTABLE TO DISA-GLOBAL.
ITEMS WITH DESIGN CONSIDERATIONS
1. CONSIDER INSTALLING ADJUSTABLE SHELVES TO THE SIDEWALLS OF THE BUILT-IN STORAGE CABINET UNDER THE CONSOLES.
THESE SHELVES MIGHT ONLY BE 6" TO 8" DEEP - TO PROVIDE SPACE FOR SMALLER EQUIPMENT (ONT, COMM DROP, ETC.).
2. IS UPS POWER REQUIRED FOR THE CONSOLES? IS UPS (OR GENERATOR BACKUP) POWER AVAILABLE IN BUILDING 10, SECTION 12? WILL A STAND-ALONE UPS BATTERY PACK BE REQUIRED FOR EACH CONSOLE? WOULD THESE STAND-ALONE UNITS NEED TO
BE PLACED INSIDE THE BUILT-IN STORAGE CABINET UNDER THE CONSOLE STATIONS?
3. THE SLAT WALL PANELS (UTILIZED FOR MONITOR MOUNTING) PROBABLY NEED TO BE INSTALLED TO A FLAT SURFACE. IT MAY NOT BE POSSIBLE TO BEND THE SLAT WALL INTO AN ARC. THE BATTLE CAPTAIN BRIDGE CONSOLES ARE CURRENTLY SHOWN WITH A
SEGMENTED (FLAT SECTIONS) SURFACE FOR THE AREA TO RECEIVE SLAT WALL.
4. EVEN IF THE UTILITY CABINETS (SHOWN IN 2/I-501) ARE OMITTED (SEE NOTE #1 TO THE LEFT) - THE UTILITY CABINETS BETWEEN THE CONSOLES AND BATTLE CAPTAIN PLATFORM (SHOWN IN 3/I-501) SHOULD BE RETAINED. THE UTILITY CABINET (3/I-501) PROVIDES A TRANSITION FROM THE FLAT END PANELS OF THE ADJACENT CONSOLE - TO THE ROUNDED PLATFORM OF THE BATTLE CAPTAIN BRIDGE CONSOLES. THE UTILITY CABINET ALSO PROVIDES WORKING SPACE AND TRANSITIONAL SPACE FOR ELECTRICAL AND COMMUNICATION CABLES BETWEEN THE FLOOR-MOUNTED CONSOLES AND THE RAISED PLATFORM.
5. THE STORAGE CONSOLE (LOCATED IN THE CENTER OF THE RAISED PLATFORM HAS BEEN DESIGNED ON THIS SET OF PLANS AS A UNIT THAT CAN BE SPLIT IN HALF - SO THAT IT CAN BE MOVED OFF THE PLATFORM (VIA THE 4' WIDE RAMP). IS THIS STORAGE
CONSOLE REQUIRED BY DISA-GLOBAL?
6. STORAGE ALONG THE RIGHT WALL OF THE ROOM (NOTED WITH KEYNOTE 5, ON SHEET I-101) HAS BEEN INCLUDED AS AN ALTERNATE BID ITEM. THIS STORAGE COULD BE LOCKERS OR OPEN CUBICLES - INTENDED FOR STORAGE OF OCCUPANTS PERSONAL ITEMS (COATS, BACKPACKS, ETC.). IF DISA-GLOBAL WISHES TO PURSUE TO THIS CONCEPT - FURTHER INFORMATION
WILL BE REQUIRED (HOW MANY UNITS, WHAT SIZE, ETC.).
| COL_G-001-G-001 |
| Sheets and Views |
| G-001 |
| COL_ID-101-ID-101 |
| Sheets and Views |
| ID-101 |
| COL_I-101-I-101 |
| Sheets and Views |
| I-101 |
| COL_GLOBAL_I-500-I-500 |
| Sheets and Views |
| I-500 |
| COL_GLOBAL_I-500-I-501 |
| Sheets and Views |
| I-501 |
| COL_GLOBAL_I-500-I-502 |
| Sheets and Views |
| I-502 |
File details come from the government source that posted it. Updated .