Attachment 5 Auto Shop Hazmat Report 2020.pdf

PDF 2 MB Posted

Attached to
Rehabilitate auto shop at Olympic National Park WA
Solicitation number
140P8321R0001
Issued by

About this file

This document provides details for a solicitation to rehabilitate an automotive repair shop at Olympic National Park in Washington. The scope of work includes removing and replacing the existing diesel fueling system with new aboveground tanks, pumps, and controls; constructing a steel-framed roof canopy over the fuel area; and rehabilitating the shop including upgrades to mechanical, plumbing, and electrical systems and replacing the metal roof. Interested women-owned small businesses may submit proposals by the due date specified in the solicitation, which will be posted on SAM.gov along with drawings and specifications. The work is to be completed within 240 calendar days of award. The National Park Service will evaluate proposals considering both technical capability and price to select the best value.

View the file

Other files

File Type Posted
Attachment 18 Clarifications 4 140P8321R0001_0005.pdf PDF
Sol_140P8321R0001_Amd_0005.pdf PDF
Attachment 19 New and Revised Specification Sections_0005.pdf PDF
Sol_140P8321R0001_Amd_0004.pdf PDF
Attachment 16 NEPA and NHPA Auto Shop Report_0004.pdf PDF
Attachment 15 Revised Sheets A1.3 and A6.0_0004.pdf PDF
Attachment 17 Section 14 46 00 - Material Lifts_rev2_0004.pdf PDF
Attachment 14 Clarifications 3 140P8321R0001_0004.pdf PDF
Attachment 12 Truck Lift Construction Drawings_1988 OLYM_149_60060_0003.pdf PDF
Attachment 13 Revised Sections 14 46 00 and 22 15 19_0003.pdf PDF
Sol_140P8321R0001_Amd_0003.pdf PDF
Attachment 11 Clarifications 2 140P8321R0001_0003.pdf PDF
Sol_140P8321R0001_Amd_0002.pdf PDF
Attachment 9 Site visit notes_clarifications_and attendees 140P8321R0001_0001.pdf PDF
Revised clauses and provisions with Amd 1 140P8321R0001_0001.pdf PDF
Attachment 10 Section 22 12 13 - Facility Fuel-Oil Pumps_revised_0001.pdf PDF
Sol_140P8321R0001_Amd_0001.pdf PDF
Attachment 2 Drawings OLYM Fuel Tank and Auto Shop.pdf PDF
Attachment 7 Spill Prevention Control and Countermeasures Plan -reduced.pdf PDF
Attachment 4 Topographic Survey of Maintenance Compound 2020.pdf PDF
FAQs for RFP 140P8321R0001.pdf PDF
form to return with proposal - Limitations on Subcontracting compliance.xlsx XLSX spreadsheet
Sol_140P8321R0001.pdf PDF
Attachment 8 Wage Determination WA44 1-1-2021.pdf PDF
Attachment 3 Auto Shop Original Construction Drawings 1957.pdf PDF
forms to return with proposal 140P8321R0001 - mandatory.docx DOCX document
forms to return with proposal 140P8321R0001 - optional templates.docx DOCX document
Attachment 6 NPDES Inspection Report_EPA.pdf PDF
Attachment 1 Specifications OLYM Fuel Tank and Auto Shop.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P:\Masters\PROJECTS\FFA Architecture 07123\-07, Olympic National Park Vehicle Maintenance Shop\Survey report 4.19.docx

Asbestos and Lead Survey Report

This report is prepared for and the property of:

FFA Architecture and Interiors, Inc.

Site:

Fuel Tank and Auto Maintenance Shop

Olympic National Park Headquarters

Report Date:

March 10, 2020

JSE Labs, Inc.

Jones-Stohosky Environmental Laboratory, Inc.

3315 SE Harrison Street, Suite C

Milwaukie, Oregon 97222

Phone: 503-659-8338

Fax: 503-659-7577 www.jselabs.com

APPENDIX I

3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222

P: 503-659-8338 | F: 503-659-7577

P:\Masters\PROJECTS\FFA Architecture 07123\-07, Olympic National Park Vehicle Maintenance Shop\Survey report 4.19.docx

JSE Labs, Inc has performed an asbestos-containing material (ACM) and Lead-containing paint survey of the Fuel Tank and Auto Maintenance Shop, Olympic National Park, Port

Angeles, Washington.

The survey consisted of identification, sampling, and sample analysis of suspect ACM and

Lead-containing paint throughout the survey area, including the exterior siding. All accessible building materials within the survey area were inspected. Demolition and sample site repair were not performed.

ASBESTOS INSPECTION SUMMARY

The following table includes all known asbestos-containing materials discovered at the site.

Material Friability/

Condition Material Extent

Approximate

Quantity

Plaster, interior of exterior walls NF/G Interior side of exterior walls

Throughout Original

Building

Notes: Friability Categories: F = Friable, NF = Non-friable in place

Condition Categories: G = Good; F = Fair; P = Poor

A sample of the cementitious plaster taken from the interior of the exterior wall in the mezzanine area contained asbestos.

All other suspect materials sampled at the building tested negative for asbestos. The list of materials sampled can be found on the sample inventory.

LEAD IN PAINT SAMPLING SUMMARY

Sampling and analysis of representative painted surfaces within the space, including exterior paint was performed. Only the yellow curb paint around the lube tanks on the interior of the building contained over 5,000 ppm lead (lead-based paint). The remaining paints with results over the detection limits are considered “lead-containing”.

Color/Location Sample Number Detection

Limit (ppm) Results (ppm)

S. Side Yellow Wood Window Sash/Sill Pb 2000226 45 90

S. Side Exterior Green Wood Siding Pb 2000227 42 1755

W. End Exterior Green Wood Siding Pb 2000228 38 <38

Yellow Curb N. Entrance Exterior Pb 2000229 44 <44

N. Entrance, Green Foundation Exterior Pb 2000230 39 304

Laundry Wall, Beige/Green Plaster Pb 2000231 40 1,000

Yellow Lube Containment Curb Interior Pb 2000232 42 23,485

Restroom Floor,Grey Epoxy Pb 2000233 44 <44 http://www.jselabs.com/

3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222

P: 503-659-8338 | F: 503-659-7577

P:\Masters\PROJECTS\FFA Architecture 07123\-07, Olympic National Park Vehicle Maintenance Shop\Survey report 4.19.docx

Samples were tested by using Flame Atomic Absorption Spectroscopy. Untested paints and varnishes should be presumed to contain lead.

Sincerely, Francis Stohosky

Attachments: Asbestos Sample Analysis Laboratory Data, Lead in Paint Analysis Laboratory

Data http://www.jselabs.com/

Client #:Client #: 07123Fletcher Farr Ayotte, Inc.

Sample

3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222

Phone: (503) 659-8338 Fax (503) 659-7577

Jones Stohosky Environmental Laboratory, www.jselabs.com

Report Date: 3/4/2020

Project Name: Olympic NP Vehicle Maint Shop

Location Material Extent Quantity

Sample Inventory

Batch #: 2499

Asbestos ContentLayer Description

Project #: Invoice PO:

NVLAP LAB CODE 200872-0

Layer

Field Service #: .07

1 None Detected07123.07-01 Newer-Sub GradeWest End Exterior

Fiber Board

Lab ID #:AB-4804

Brown/black fiber board

1 07123.07-02 WallsMezzanine

Plaster

Lab ID #:AB-4805

Grey/white cementitous compound

Amosite 2%

Chrysotile <1%

1 None Detected07123.07-03 WallsMain Office

Gypsum/Joint

Lab ID #:AB-4806

White paint w/ cream paper and compound

2 None Detected

1 None Detected07123.07-04 WallsWelding Shop

Gypsum/Joint

Lab ID #:AB-4807

Green paint w/ cream paper and compound

2 None DetectedWhite gypsum w/ paper

1 None Detected07123.07-05 WallsLaundry Room

Plaster

Lab ID #:AB-4808

Green paint

2 None DetectedGray coarse-grained plaster

1 None Detected07123.07-06 Exterior Older Sub Grade

West End Exterior

Fiber Board

Lab ID #:AB-4809

Black thick, shiny tar

1 None Detected07123.07-07 Domestic Water Pipe

Mezzanine

FG

Lab ID #:AB-4810

White woven sheet

2 None DetectedYellow fibrous bundles

Analysis Method: EPA-600/M4-82-020 and EPA 600/R-93/116 Methods using PLM - for asbestos fiber identification.

1 None Detected07123.07-08 Ceiling PanelMezzanine

Foil/Foam

Lab ID #:AB-4811

Silver foil

2 None DetectedYellow foam

Analysis Method: EPA-600/M4-82-020 and EPA 600/R-93/116 Methods using PLM - for asbestos fiber identification.

Client #:Client: 07123Fletcher Farr Ayotte, Inc.

Asbestos Analysis of Bulk Materials by Polarized Light Microscopy

Binder/MatrixSample DescriptionLayer Non-Asbestos Components Asbestos Type %

3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222

Phone: (503) 659-8338 Fax: (503) 659-7577

Jones Stohosky Environmental Laboratory, Inc.

www.jselabs.com

Report Date: 3/4/2020

Project Name: Olympic NP Vehicle Maint Shop

NVLAP LAB CODE 200872-0

Project #: Invoice PO: Batch #: 2499

07123.07-01

Lab ID #: AB-4804

Brown/black fiber board Filler

Binders

1 None DetectedCellulose 75%

Sample ashed for quality assurance.

07123.07-02

Lab ID #: AB-4805

Grey/white cementitous compound

Cementitious

Filler

1 Amosite 2%

Chrysotile <1%

Sample ashed for quality assurance.

07123.07-03

Lab ID #: AB-4806

White paint w/ cream paper and compound

Paint

Acid soluble

1 None DetectedCellulose 10%

Acid soluble

Paper

2 None Detected

Sample ashed for quality assurance.

07123.07-04

Lab ID #: AB-4807

Green paint w/ cream paper and compound

Paint

Paper

1 None DetectedFibrous Glass 2%

Cellulose 10%

White gypsum w/ paper Gypsum

Paper

2 None DetectedFibrous Glass 1%

Cellulose 10%

Subsamples ashed for quality assurance. Analysis of the brown fibrous paper layer is included in the analysis of the gypsum wallboard layer. Both gypsum and paper tested negative for asbestos.

07123.07-05

Lab ID #: AB-4808

Green paint Paint

Binders

1 None Detected

Gray coarse-grained plaster Rock particles

Filler

2 None DetectedCellulose 5%

Subsamples ashed for quality assurance.

07123.07-06

Lab ID #: AB-4809

Black thick, shiny tar Asphaltic

Filler

1 None DetectedFibrous Glass 1%

Cellulose 40%

Sample ashed for quality assurance.

07123.07-07

Lab ID #: AB-4810

White woven sheet Binders

Filler

1 None Detected

Yellow fibrous bundles Filler2 None DetectedFibrous Glass 95%

Subsamples ashed for quality assurance.

07123.07-08

Lab ID #: AB-4811

Silver foil Metal

Binders

1 None Detected

Yellow foam Foam

Filler

2 None Detected

Subsamples ashed for quality assurance.

JSE is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for bulk asbestos analysis by EPA-600/M4-82-020 and EPA/600/R-93/116 methods for polarized light microscopy (PLM). These analysis results apply to the sample(s) as received. Asbestos content for an inhomogeneous sample is reported by layer when it is possible to subsample the discrete strata for individual analysis. Small diameter fibers may not be detected by this method. Information supplied by the customer does not affect the validity of PLM results obtained by the EPA 600/R-93/116 method. Customers will be informed (in comments section) if specific environmental or test conditions affect the interpretation of test results. All analysis results conform to the EPA 600/R-93/116, Method for the Determination of Asbestos in Bulk Building Materials. Quantification is performed using visual area estimation unless otherwise stated in the report. Qualitative and quantitative transmission electron microscopy (TEM) analysis may be recommended for difficult samples. Quantitative analysis by PLM point count or TEM is recommended for sample(s) testing at < or = to 10% asbestos. Uncertainty values are as follows: Trace–<5.0%: ±250%; 5.0–39 <10%: ±150%; 10–<30%: ±100%;

30–<60%: ±50%; 60–100%: ±25%. Asbestos includes the following minerals: chrysotile, amosite, crocidolite, tremolite, actinolite, anthophyllite. "Matrix" is defined as non-asbestos, non-binder fibrous and non-fibrous components. "Binder" is defined as a component added for cohesiveness. Non-asbestos sample constituents may not be definite. This report may not be used to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the Federal Government. If the NVLAP logo does not appear beneath the JSE logo of this report then "This report contains data not covered by the NVLAP accreditation." (NIST Handbook 150, 2006.) Amended reports supersede all previous reports.

Approved Signatory:

Analyst Name: Anitta Limpichart, Brianna Young 3/4/2020Date:

Survey report 4.19.pdf (p.1-3)
CoC, PLM Results.pdf (p.4-8)
CoC, Pb Results .pdf (p.9-10)