This document provides details for a solicitation to rehabilitate an automotive repair shop at Olympic National Park in Washington. The scope of work includes removing and replacing the existing diesel fueling system with new aboveground tanks, pumps, and controls; constructing a steel-framed roof canopy over the fuel area; and rehabilitating the shop including upgrades to mechanical, plumbing, and electrical systems and replacing the metal roof. Interested women-owned small businesses may submit proposals by the due date specified in the solicitation, which will be posted on SAM.gov along with drawings and specifications. The work is to be completed within 240 calendar days of award. The National Park Service will evaluate proposals considering both technical capability and price to select the best value.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P:\Masters\PROJECTS\FFA Architecture 07123\-07, Olympic National Park Vehicle Maintenance Shop\Survey report 4.19.docx
Asbestos and Lead Survey Report
This report is prepared for and the property of:
FFA Architecture and Interiors, Inc.
Site:
Fuel Tank and Auto Maintenance Shop
Olympic National Park Headquarters
Report Date:
March 10, 2020
JSE Labs, Inc.
Jones-Stohosky Environmental Laboratory, Inc.
3315 SE Harrison Street, Suite C
Milwaukie, Oregon 97222
Phone: 503-659-8338
Fax: 503-659-7577 www.jselabs.com
APPENDIX I
3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222
P: 503-659-8338 | F: 503-659-7577
P:\Masters\PROJECTS\FFA Architecture 07123\-07, Olympic National Park Vehicle Maintenance Shop\Survey report 4.19.docx
JSE Labs, Inc has performed an asbestos-containing material (ACM) and Lead-containing paint survey of the Fuel Tank and Auto Maintenance Shop, Olympic National Park, Port
Angeles, Washington.
The survey consisted of identification, sampling, and sample analysis of suspect ACM and
Lead-containing paint throughout the survey area, including the exterior siding. All accessible building materials within the survey area were inspected. Demolition and sample site repair were not performed.
ASBESTOS INSPECTION SUMMARY
The following table includes all known asbestos-containing materials discovered at the site.
Material Friability/
Condition Material Extent
Approximate
Quantity
Plaster, interior of exterior walls NF/G Interior side of exterior walls
Throughout Original
Building
Notes: Friability Categories: F = Friable, NF = Non-friable in place
Condition Categories: G = Good; F = Fair; P = Poor
A sample of the cementitious plaster taken from the interior of the exterior wall in the mezzanine area contained asbestos.
All other suspect materials sampled at the building tested negative for asbestos. The list of materials sampled can be found on the sample inventory.
LEAD IN PAINT SAMPLING SUMMARY
Sampling and analysis of representative painted surfaces within the space, including exterior paint was performed. Only the yellow curb paint around the lube tanks on the interior of the building contained over 5,000 ppm lead (lead-based paint). The remaining paints with results over the detection limits are considered “lead-containing”.
Color/Location Sample Number Detection
Limit (ppm) Results (ppm)
S. Side Yellow Wood Window Sash/Sill Pb 2000226 45 90
S. Side Exterior Green Wood Siding Pb 2000227 42 1755
W. End Exterior Green Wood Siding Pb 2000228 38 <38
Yellow Curb N. Entrance Exterior Pb 2000229 44 <44
N. Entrance, Green Foundation Exterior Pb 2000230 39 304
Laundry Wall, Beige/Green Plaster Pb 2000231 40 1,000
Yellow Lube Containment Curb Interior Pb 2000232 42 23,485
Restroom Floor,Grey Epoxy Pb 2000233 44 <44 http://www.jselabs.com/
3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222
P: 503-659-8338 | F: 503-659-7577
P:\Masters\PROJECTS\FFA Architecture 07123\-07, Olympic National Park Vehicle Maintenance Shop\Survey report 4.19.docx
Samples were tested by using Flame Atomic Absorption Spectroscopy. Untested paints and varnishes should be presumed to contain lead.
Sincerely, Francis Stohosky
Attachments: Asbestos Sample Analysis Laboratory Data, Lead in Paint Analysis Laboratory
Data http://www.jselabs.com/
Client #:Client #: 07123Fletcher Farr Ayotte, Inc.
Sample
3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222
Phone: (503) 659-8338 Fax (503) 659-7577
Jones Stohosky Environmental Laboratory, www.jselabs.com
Report Date: 3/4/2020
Project Name: Olympic NP Vehicle Maint Shop
Location Material Extent Quantity
Sample Inventory
Batch #: 2499
Asbestos ContentLayer Description
Project #: Invoice PO:
NVLAP LAB CODE 200872-0
Layer
Field Service #: .07
1 None Detected07123.07-01 Newer-Sub GradeWest End Exterior
Fiber Board
Lab ID #:AB-4804
Brown/black fiber board
1 07123.07-02 WallsMezzanine
Plaster
Lab ID #:AB-4805
Grey/white cementitous compound
Amosite 2%
Chrysotile <1%
1 None Detected07123.07-03 WallsMain Office
Gypsum/Joint
Lab ID #:AB-4806
White paint w/ cream paper and compound
2 None Detected
1 None Detected07123.07-04 WallsWelding Shop
Gypsum/Joint
Lab ID #:AB-4807
Green paint w/ cream paper and compound
2 None DetectedWhite gypsum w/ paper
1 None Detected07123.07-05 WallsLaundry Room
Plaster
Lab ID #:AB-4808
Green paint
2 None DetectedGray coarse-grained plaster
1 None Detected07123.07-06 Exterior Older Sub Grade
West End Exterior
Fiber Board
Lab ID #:AB-4809
Black thick, shiny tar
1 None Detected07123.07-07 Domestic Water Pipe
Mezzanine
FG
Lab ID #:AB-4810
White woven sheet
2 None DetectedYellow fibrous bundles
Analysis Method: EPA-600/M4-82-020 and EPA 600/R-93/116 Methods using PLM - for asbestos fiber identification.
1 None Detected07123.07-08 Ceiling PanelMezzanine
Foil/Foam
Lab ID #:AB-4811
Silver foil
2 None DetectedYellow foam
Analysis Method: EPA-600/M4-82-020 and EPA 600/R-93/116 Methods using PLM - for asbestos fiber identification.
Client #:Client: 07123Fletcher Farr Ayotte, Inc.
Asbestos Analysis of Bulk Materials by Polarized Light Microscopy
Binder/MatrixSample DescriptionLayer Non-Asbestos Components Asbestos Type %
3315 SE Harrison Street, Suite C, Milwaukie, Oregon 97222
Phone: (503) 659-8338 Fax: (503) 659-7577
Jones Stohosky Environmental Laboratory, Inc.
www.jselabs.com
Report Date: 3/4/2020
Project Name: Olympic NP Vehicle Maint Shop
NVLAP LAB CODE 200872-0
Project #: Invoice PO: Batch #: 2499
07123.07-01
Lab ID #: AB-4804
Brown/black fiber board Filler
Binders
1 None DetectedCellulose 75%
Sample ashed for quality assurance.
07123.07-02
Lab ID #: AB-4805
Grey/white cementitous compound
Cementitious
Filler
1 Amosite 2%
Chrysotile <1%
Sample ashed for quality assurance.
07123.07-03
Lab ID #: AB-4806
White paint w/ cream paper and compound
Paint
Acid soluble
1 None DetectedCellulose 10%
Acid soluble
Paper
2 None Detected
Sample ashed for quality assurance.
07123.07-04
Lab ID #: AB-4807
Green paint w/ cream paper and compound
Paint
Paper
1 None DetectedFibrous Glass 2%
Cellulose 10%
White gypsum w/ paper Gypsum
Paper
2 None DetectedFibrous Glass 1%
Cellulose 10%
Subsamples ashed for quality assurance. Analysis of the brown fibrous paper layer is included in the analysis of the gypsum wallboard layer. Both gypsum and paper tested negative for asbestos.
07123.07-05
Lab ID #: AB-4808
Green paint Paint
Binders
1 None Detected
Gray coarse-grained plaster Rock particles
Filler
2 None DetectedCellulose 5%
Subsamples ashed for quality assurance.
07123.07-06
Lab ID #: AB-4809
Black thick, shiny tar Asphaltic
Filler
1 None DetectedFibrous Glass 1%
Cellulose 40%
Sample ashed for quality assurance.
07123.07-07
Lab ID #: AB-4810
White woven sheet Binders
Filler
1 None Detected
Yellow fibrous bundles Filler2 None DetectedFibrous Glass 95%
Subsamples ashed for quality assurance.
07123.07-08
Lab ID #: AB-4811
Silver foil Metal
Binders
1 None Detected
Yellow foam Foam
Filler
2 None Detected
Subsamples ashed for quality assurance.
JSE is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for bulk asbestos analysis by EPA-600/M4-82-020 and EPA/600/R-93/116 methods for polarized light microscopy (PLM). These analysis results apply to the sample(s) as received. Asbestos content for an inhomogeneous sample is reported by layer when it is possible to subsample the discrete strata for individual analysis. Small diameter fibers may not be detected by this method. Information supplied by the customer does not affect the validity of PLM results obtained by the EPA 600/R-93/116 method. Customers will be informed (in comments section) if specific environmental or test conditions affect the interpretation of test results. All analysis results conform to the EPA 600/R-93/116, Method for the Determination of Asbestos in Bulk Building Materials. Quantification is performed using visual area estimation unless otherwise stated in the report. Qualitative and quantitative transmission electron microscopy (TEM) analysis may be recommended for difficult samples. Quantitative analysis by PLM point count or TEM is recommended for sample(s) testing at < or = to 10% asbestos. Uncertainty values are as follows: Trace–<5.0%: ±250%; 5.0–39 <10%: ±150%; 10–<30%: ±100%;
30–<60%: ±50%; 60–100%: ±25%. Asbestos includes the following minerals: chrysotile, amosite, crocidolite, tremolite, actinolite, anthophyllite. "Matrix" is defined as non-asbestos, non-binder fibrous and non-fibrous components. "Binder" is defined as a component added for cohesiveness. Non-asbestos sample constituents may not be definite. This report may not be used to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the Federal Government. If the NVLAP logo does not appear beneath the JSE logo of this report then "This report contains data not covered by the NVLAP accreditation." (NIST Handbook 150, 2006.) Amended reports supersede all previous reports.
Approved Signatory:
Analyst Name: Anitta Limpichart, Brianna Young 3/4/2020Date:
| Survey report 4.19.pdf (p.1-3) |
| CoC, PLM Results.pdf (p.4-8) |
| CoC, Pb Results .pdf (p.9-10) |
File details come from the government source that posted it. Updated .