This federal solicitation requests proposals to rehabilitate an automotive repair shop and fueling system at Olympic National Park in Washington. Key details include rehabilitating the shop building including mechanical, plumbing and electrical upgrades, replacing the metal roof, and removing the existing diesel fuel tanks and pump to install new aboveground tanks and controls. The work must be completed within 240 calendar days of award.
This is a best value procurement set aside for women-owned small businesses. The NAICS code is 236220 for commercial and institutional building construction. Proposals are due approximately 30 days after posting of the solicitation on SAM.gov. The contractor must provide payment and performance bonds as well as liability insurance. The site visit will take place on January 19, 2021 and attendance is strongly encouraged. The National Park Service Pacific West Region is the contracting agency.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 14 46 00 - MATERIAL LIFTS
OLYM - 228422 14 46 00 - 1
MATERIAL LIFTS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Wall mounted material lift.
1.02 RELATED SECTIONS
A. Section 06 10 00 - Rough Carpentry
B. Section 09 21 16 - Gypsum Board Assemblies
C. Section 26 28 16 - Disconnect Switches and Individual Motor Controllers
1.03 SUBMITTALS
A. See Section 01 33 23 Submittal Procedures, for submittal procedures.
B. General and Structural Notes on the Structural Drawings
C. Product Data: Show product data of proposed product, including required structural support and electrical connection power loads. Indicate any related code required features to be provided by others.
D. Shop Drawings: Include layout in building space in plan, section, and elevation integrated with existing construction; loading height, details of equipment connection to floor, wall;
bracing requirements, special conditions; operating controls locations.
E. Manufacturer's Installation Instructions.
F. Maintenance and Operations: Manufacturer's printed operation and maintenance requirements and recommendations. Include name and contact information of nearest service representative.
G. Warranty: Manufacturer's warranty
1.04 WARRANTY
A. Manufacturer's standard 24 month material and operational warranty. Make any repairs or adjustments required in warranty period.
Revision 2. Significant changes to 2.01 B paragraphs; minor changes elsewhere.
OLYM - 228422 14 46 00 - 2
MATERIAL LIFTS
PART 2 PRODUCTS
2.01 GENERAL
A. Code Compliance: System must comply with any local, state, or federal codes governing such a system.
B. Description: Wall mounted material lift system, consisting of, but not limited to, the following, to provide a complete operable system:
1. Capacity: A minimum of 150 pounds of load
2. Stops: Two floors.
3. Rise: A minimum of ten (12) feet between stops.
4. Speed: 1-1/2 feet per second.
5. Motor: 3/4 horsepower, 220 volt.
6. Wall mounted frame: Welded tubing and panel infill assembly of steel components, to support the control, operating and moving parts of the system.
7. Material platform: Approximately 24 inches by 24 inches by 30 inches high, or larger.
8. Finish: Manufacturer's standard powder coat or PVDF coating system.
a. Frame and infill panel color: PNT-4 per Section 09 91 23.
b. Moving material platform color: Safety yellow.
9. Operations:
a. Electrical geared, hydraulic, or mixed hydraulic and cable/pully system per manufacturer's standard.
10. Controls:
a. Two station, manual, call/send buttons, door interlocks, door safety switches, and emergency safety stop switch.
11. Products: Basis of Design:
a. 2 STOP MEZ-LIFT 100. www.dumbwaiters.com
b. Substitutions: See Section 01 67 00 – Product Requirements
PART 3 EXECUTION
3.01 INSTALLATION
A. Install per manufacturer's instruction and approved shop drawings.
3.02 ADJUSTMENT
A. Adjust equipment for smooth operation.
OLYM - 228422 14 46 00 - 3
MATERIAL LIFTS
3.03 TRAINING:
A. Provide a minimum of one hour of orientation and training for Owner's personnel.
END OF SECTION
| part 1 general |
| 1.01 section includes |
| A. Wall mounted material lift. |
| 1.02 related sections |
| A. Section 06 10 00 - Rough Carpentry |
| B. Section 09 21 16 - Gypsum Board Assemblies |
| C. Section 26 28 16 - Disconnect Switches and Individual Motor Controllers |
| 1.03 submittals |
| A. See Section 01 33 23 Submittal Procedures, for submittal procedures. |
| B. General and Structural Notes on the Structural Drawings |
| C. Product Data: Show product data of proposed product, including required structural support and electrical connection power loads. Indicate any related code required features to be provided by others. |
| D. Shop Drawings: Include layout in building space in plan, section, and elevation integrated with existing construction; loading height, details of equipment connection to floor, wall; bracing requirements, special conditions; operating controls loca... |
| E. Manufacturer's Installation Instructions. |
| F. Maintenance and Operations: Manufacturer's printed operation and maintenance requirements and recommendations. Include name and contact information of nearest service representative. |
| G. Warranty: Manufacturer's warranty |
| 1.04 Warranty |
| A. Manufacturer's standard 24 month material and operational warranty. Make any repairs or adjustments required in warranty period. |
| PART 2 PRODUCTS |
| 2.01 general |
| A. Code Compliance: System must comply with any local, state, or federal codes governing such a system. |
| B. Description: Wall mounted material lift system, consisting of, but not limited to, the following, to provide a complete operable system: |
| 1. Capacity: A minimum of 150 pounds of load |
| 2. Stops: Two floors. |
| 3. Rise: A minimum of ten (12) feet between stops. |
| 4. Speed: 1-1/2 feet per second. |
| 5. Motor: 3/4 horsepower, 220 volt. |
| 6. Wall mounted frame: Welded tubing and panel infill assembly of steel components, to support the control, operating and moving parts of the system. |
| 7. Material platform: Approximately 24 inches by 24 inches by 30 inches high, or larger. |
| 8. Finish: Manufacturer's standard powder coat or PVDF coating system. |
| a. Frame and infill panel color: PNT-4 per Section 09 91 23. |
| b. Moving material platform color: Safety yellow. |
| 9. Operations: |
| a. Electrical geared, hydraulic, or mixed hydraulic and cable/pully system per manufacturer's standard. |
| 10. Controls: |
| a. Two station, manual, call/send buttons, door interlocks, door safety switches, and emergency safety stop switch. |
| 11. Products: Basis of Design: |
| a. 2 STOP MEZ-LIFT 100. www.dumbwaiters.com |
| b. Substitutions: See Section 01 67 00 – Product Requirements |
| PART 3 EXECUTION |
| 3.01 Installation |
| A. Install per manufacturer's instruction and approved shop drawings. |
| 3.02 Adjustment |
| A. Adjust equipment for smooth operation. |
| 3.03 Training: |
| A. Provide a minimum of one hour of orientation and training for Owner's personnel. |