This document provides details for a solicitation seeking rehabilitation services for an automotive repair shop located within Olympic National Park. The solicitation will require removing and replacing an existing diesel fueling system with aboveground tanks, pumps, and piping. Additional work includes constructing a roof canopy over the fuel area, reconfiguring stormwater piping, and rehabilitating the shop including mechanical, plumbing, and electrical upgrades along with replacing the metal roof. The National Park Service is seeking these services through a best value procurement set aside for women-owned small businesses. Offerors must be certified as a WOSB by the SBA. The prime contractor must comply with limitations on subcontracting, and the work will be performed under a single firm-fixed-price construction contract subject to prevailing wage requirements. The period of performance is 240 calendar days after notice to proceed. The solicitation and any amendments will be posted on SAM.gov, with responses due approximately 30 days later. Proposals will include both technical and price components, and award will be made based on best value.

View the file

Other files

File Type Posted
Attachment 18 Clarifications 4 140P8321R0001_0005.pdf PDF
Sol_140P8321R0001_Amd_0005.pdf PDF
Attachment 19 New and Revised Specification Sections_0005.pdf PDF
Sol_140P8321R0001_Amd_0004.pdf PDF
Attachment 16 NEPA and NHPA Auto Shop Report_0004.pdf PDF
Attachment 17 Section 14 46 00 - Material Lifts_rev2_0004.pdf PDF
Attachment 14 Clarifications 3 140P8321R0001_0004.pdf PDF
Attachment 12 Truck Lift Construction Drawings_1988 OLYM_149_60060_0003.pdf PDF
Attachment 13 Revised Sections 14 46 00 and 22 15 19_0003.pdf PDF
Sol_140P8321R0001_Amd_0003.pdf PDF
Attachment 11 Clarifications 2 140P8321R0001_0003.pdf PDF
Sol_140P8321R0001_Amd_0002.pdf PDF
Attachment 9 Site visit notes_clarifications_and attendees 140P8321R0001_0001.pdf PDF
Revised clauses and provisions with Amd 1 140P8321R0001_0001.pdf PDF
Attachment 10 Section 22 12 13 - Facility Fuel-Oil Pumps_revised_0001.pdf PDF
Sol_140P8321R0001_Amd_0001.pdf PDF
Attachment 2 Drawings OLYM Fuel Tank and Auto Shop.pdf PDF
Attachment 7 Spill Prevention Control and Countermeasures Plan -reduced.pdf PDF
Attachment 4 Topographic Survey of Maintenance Compound 2020.pdf PDF
FAQs for RFP 140P8321R0001.pdf PDF
Attachment 5 Auto Shop Hazmat Report 2020.pdf PDF
form to return with proposal - Limitations on Subcontracting compliance.xlsx XLSX spreadsheet
Sol_140P8321R0001.pdf PDF
Attachment 8 Wage Determination WA44 1-1-2021.pdf PDF
Attachment 3 Auto Shop Original Construction Drawings 1957.pdf PDF
forms to return with proposal 140P8321R0001 - mandatory.docx DOCX document
forms to return with proposal 140P8321R0001 - optional templates.docx DOCX document
Attachment 6 NPDES Inspection Report_EPA.pdf PDF
Attachment 1 Specifications OLYM Fuel Tank and Auto Shop.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A3.1

A3.1

A3.1

A3.1

ABCDEFGH

11' - 3" 16' - 3" 16' - 0" 16' - 0" 16' - 0" 16' - 3" 36' - 7"

S L O P E

A3.1

S L O P E

S L O P E

L O P E

S L O P E

S L O P E

A5.0

24' - 9"

4 4 4

4 4 4

XB XA

1.1

30' - 8" 18' - 0"

A5.0

ROOF EDGE TO FUEL TANK

15' MIN

A5.0

A5.0

A5.0

A5.0

A5.0

A5.0

A5.0

A5.0

A5.0

A5.0

A5.0

A5.1

A5.1

A5.1

A5.1

5883 REGISTERED

ARCHITECT

STATE OF WASHINGTON

TROY A. AINSWORTH

8 0 8 16

SCALE OF FEET

DESIGNED:

DRAWN:

TECH. REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET

DRAWING NO.

PMIS/PKG NO.

DRAWING NO.

D R

A W

IN

G

S T

O B

E P

R

IN

T E

D I

N G

R A

Y S

C A

L E

IF

D

IS

T

IN

C

T S

H A

D E

O F

D O

T S

A R

E N

O T

V

IS

IB

L

E

IN

F O

R M

A T

IO

N

M A

Y B

E M

IS

S

IN

G

OF

A1.3 12/18/2020

TM

AL

TM/AL 149

166287

OLYMPIC NATIONAL PARK

ROOF PLAN

ROOF PLAN

SHEET NOTES

1. INDICATED ROOF SLOPES ARE FOR ESTIMATION

PURPOSES ONLY. EXACT ROOF SLOPE FOR

CONSTRUCTION TO BE VERIFIED BY CONTRACTOR PRIOR

TO COMMENCEMENT OF WORK. DISCREPANCIES TO BE

PROVIDED TO CONTRACTING OFFICER PRIOR TO

COMMENCEMENT OF WORK.

KEYNOTES

1 (N) PAINTED STANDING SEAM METAL ROOF ASSEMBLY,

INCLUDING WEATHER BARRIER, RIGID INSULATION,

DRAINAGE LAYER, PLYWOOD SHEATHING (WHERE

OCCURS), FASCIA-MOUNTED PAINTED METAL GUTTERS,

AND DOWNSPOUTS

2 (N) PAINTED STANDING SEAM METAL ROOF ON

CORRUGATED METAL DECK WITH FASCIA-MOUNTED

PAINTED METAL GUTTERS AND DOWNSPOUTS

3 (E) VENT THROUGH ROOF - SEE PLUMBING DRAWINGS

FOR PIPING CONNECTION

4 (N) DOWNSPOUT - SEE CIVIL DRAWINGS FOR

STORMWATER CONNECTION

5 1/8" DIFFERENCE BETWEEN (N) ROOF SHEATHING (AUTO

REPAIR) AND (E) ROOF SHEATHING (WELDING) THICKNESS

TO BE MADE UP IN RIGID INSULATION LAYER

228422

A OF

GROUND FLOOR

0' - 0"

GROUND FLOOR

0' - 0"

GROUND FLOOR

0' - 0"

EQEQ

GROUND FLOOR

0' - 0"

T.O. PLATE

14' - 6"

MEZZANINE

9' - 6"

4' - 0"

20' - 0"

GROUND FLOOR

0' - 0"

T.O. PLATE

14' - 6"

MEZZANINE

9' - 6"

OPEN

A6.5

6' - 1"

11' - 7"

(N) 3-HR WALL EXTENTS

5883 REGISTERED

ARCHITECT

STATE OF WASHINGTON

TROY A. AINSWORTH

4 0 4 8

SCALE OF FEET

DESIGNED:

DRAWN:

TECH. REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET

DRAWING NO.

PMIS/PKG NO.

DRAWING NO.

D R

A W

IN

G

S T

O B

E P

R

IN

T E

D I

N G

R A

Y S

C A

L E

IF

D

IS

T

IN

C

T S

H A

D

F

D O

T S

A R

E N

O T

V

IS

IB

L

E

IN

F O

R M

A T

IO

N

M A

Y B

E M

IS

S

IN

G

OF

A6.0 12/18/2020

Checker

Author

Designer 149

228422

166287

OLYMPIC NATIONAL PARK

INTERIOR ELEVATIONS

STAFF RESTROOM 107 -

NORTH INTERIOR ELEVATION

STAFF RESTROOM 107 -

EAST INTERIOR ELEVATION

STAFF RESTROOM 107 -

SOUTH INTERIOR ELEVATION

STAFF RESTROOM 107 -

WEST INTERIOR ELEVATION

WELDING & FABRICATION 103 - WEST INTERIOR ELEVATION

ELEVATION - MEZZANINE OPENING

KEYNOTES

1 (N) METAL GUARDRAIL, FIXED ATTACHMENT, TYP

2 (N) 4x4x1/4 HSS STRUCTURAL STEEL COLUMN

3 (N) FRP WALL FINISH UP TO 5' HEIGHT, ALL INTERIOR

WALLS AT STAFF RESTROOM 107

4 (N) DOOR PER SCHEDULE

5 (N) 3-HOUR FIRE WALL

6 (N) FRP WALL FINISH, 4' WIDE x 6' HIGH FOR

PROTECTION BEHIND EYEWASH

7 (N) GYPSUM BOARD PROTECTION AT UNDERSIDE OF

ROOF STRUCTURE PER 3-HOUR ASSEMBLY

REQUIREMENTS

8 (E) GYPSUM BOARD CEILING

9 (N) MECHANICAL VENT

, FLOOR TO ROOF SHEATHING, INCLUDING INTO SOFFIT CAVITIES

LEGEND

A OF

ACCESSIBLE TOILET & GRAB BARS ACCESSIBLE LAVATORY & ACCESSORIES

JUMBO TOILET

PAPER DISPENSER

MIRROR

OUTLET OR T-STAT

SOAP DISPENSER

PAPER TOWEL

DISPENSER

C L R

F

.O .F

3'-6" MIN. 1'-0" MAX.

M

IN

T .O

S

E A

T

M

IN

M

IN

8"

M A

X

M

IN

M A

X

M

IN

M A

X

T

R

F

L E

C T

IV

U R

F A

C E

M

IN

M A

X

M A

X . 7

M

IN

NOTE: OPERABLE PART OF ALL

ACCCESSORIES TO BE LOCATED

15" MIN. - 48" MAX. AFF

CL

CL

A1.3_Roof Plan_rev1
Sheets
A1.3 - ROOF PLAN
A6.0 Interior Elevations_rev1
Sheets
A6.0 - INTERIOR ELEVATIONS

File details come from the government source that posted it. Updated .