Attachment 20 - 10 14 02 INTERIOR SIGNAGE.pdf

PDF 171 KB Posted

Attached to
Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR Federal contract opportunity
Solicitation number
FA446021R0009
Issued by
Department of the Air Force Air Mobility Command

About this file

This document provides specifications for interior signage required under a Multiple Award Construction Contract (MACC) for Little Rock Air Force Base in Arkansas. The signage specifications include requirements for room identification signs, changeable message signs, building directories, dimensional letters, plaques, and pressure sensitive vinyl letters. The specifications provide details on approved materials, fonts, sizes, finishes, braille and pictogram requirements, and fabrication and installation methods. Signage must conform to ADA and other accessibility standards. The related federal contract opportunity is for general construction projects in support of base facilities under an Indefinite-Delivery Indefinite-Quantity (IDIQ) Multiple Award Construction Contract. Construction types may include administrative, industrial, maintenance, warehouses, communications, personnel support, recreation, lodging, medical, training, ranges, roads and other facility types. Work will be identified in individual task orders and may include design/build services.

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR, newest first.
File Type Posted
Amend 05 -Solicitation Amendment - FA446021R00090005.pdf PDF
Amend 05 -Attachment 38 Questions and Answers after 3rd Site visit.pdf PDF
Amend 05 -Attachment 32 Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Amend 05 -Attachment 13 - Statement of Work for MACC Rev 1.pdf PDF
Amend 05 -Updated Attachment 30 - Past Performance Package..docx DOCX document
Solicitation Amendment FA446021R00090004 SF 30.pdf PDF
Amend 04 -Attachment 36 - Site Visit Sign-in-Sheet 6-15-21.pdf PDF
Amend 04 -Attachment 37 - 2nd Site Visit Sign-in-Sheet 6-23-21.pdf PDF
Solicitation Amendment - FA446021R00090004.pdf PDF
Amend 04 -Attachment 32 Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Attachment 32 Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Solicitation Amendment FA446021R00090003 SF 30.pdf PDF
Updated Attachment 30 - Past Performance Package.docx DOCX document
Attachment 34 - PPI Tool Download Instructions.pdf PDF
Solicitation Amendment FA446021R00090002 SF 30.pdf PDF
Solicitation Amendment FA446021R00090001 SF 30.pdf PDF
Attachment 32 - Convert Mission Planning Cell B-380 Seed Project Amend 1.zip ZIP file
Amend 0001-Solicitation - FA446021R0009 Rel.pdf PDF
Attachment 28 - Financial Institution Reference Sheet.pdf PDF
Attachment 23 - 27 20 00 COMPUTER-TELEPHONE SYSTEMS May 2010.pdf PDF
Attachment 12 - Scheduled Government Furnished Property.pdf PDF
Attachment 1 - EMIS Instruction Guide.pdf PDF
Attachment 22 - 26 05 04 RACEWAYS.pdf PDF
Attachment 25 - 28 31 00 FIRE DETECTION AND ALARM SYSTEMS.pdf PDF
Attachment 24 - 27 51 16 BUILDING MASS NOTIFICATION SYSTEM.pdf PDF
Attachment 19 - 09 06 89 TYPICAL FINISH SCHEDULE.pdf PDF
Attachment 17 - 01 57 22 TREE PRESERVATION.pdf PDF
Attachment 14 - ETL 07-04 AIR FORCE CARPET STANDARD.pdf PDF
Attachment 13 - Statement of Work for MACC.pdf PDF
Attachment 11 - LRAFB Arch Design Guide Supplement 6 Aug 20.pdf PDF
Attachment 10 - LRAFB Arch Compatibility Guide.pdf PDF
Attachment 8 - LRAFB Telecommunications Systems Design.pdf PDF
Attachment 3 - CandD Report.pdf PDF
Attachment 2 - Environmental MOA.pdf PDF
Attachment 32 - Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Attachment 29 - Maintainability Review Checklist FORM - Design Team.docx DOCX document
Attachment 27 - EZSource PresentPast Performance Relevancy Table .docx DOCX document
Attachment 26 - Design Review Checklist including constructability review 2013 07 30.docx DOCX document
Attachment 18 - 08 71 00 DOOR HARDWARE.pdf PDF
Attachment 16 - 00 00 02 LRAFB SPECIFICATIONS FORMAT STANDARD.pdf PDF
Attachment 9 - LRAFB Architectural Design Guide Supplement.pdf PDF
Attachment 7 - LRAFB Mechanical Design Criteria.pdf PDF
Attachment 30 - Past Performance Package.docx DOCX document
Attachment 33- SubKTR_Consent_Form.pdf PDF
Attachment 21 - 10 44 16 FIRE EXTINGUISHERS - CABINETS.pdf PDF
Attachment 15 - UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings.pdf PDF
Attachment 6 - LRAFB Electrical Design Standards.pdf PDF
Attachment 5 - LRAFB Information.pdf PDF
Attachment 4 - LRAFB Civil Design Criteria.pdf PDF
Released Solicitation - FA446021R0009.pdf PDF
Show all 50

Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INTERIOR SIGNAGE 10 14 02 - 1

DIVISION 10 – SPECIALTIES

SECTION 10 14 02 – INTERIOR SIGNAGE (10440)

PART 1 - GENERAL

1.01 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

ALUMINUM ASSOCIATION (AA)

AA DAF-45 (2003) Designation System for Aluminum Finishes AA PK-1 (2002) Pink Sheets: Designations and Chemical

Composition Limits for Aluminum Alloys in the Form of Castings and Ingot

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA 2604 (2005) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI Z97.1 (2004) Safety Glazing Materials Used in Buildings

AMERICAN WELDING SOCIETY (AWS)

AWS D1.2/D1.2M (2003; Errata 2004) Structural Welding Code - Aluminum

ASTM INTERNATIONAL (ASTM)

ASTM B 209 (2006) Standard Specification for Aluminum and

Aluminum-Alloy Sheet and Plate ASTM B 209M (2006) Standard Specification for Aluminum and

Aluminum-Alloy Sheet and Plate (Metric) ASTM B 221 (2006) Standard Specification for Aluminum and

Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

ASTM B 221M (2006) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)

ASTM C 1036 (2006) Standard Specification for Flat Glass ASTM D 635 (2006) Standard Test Method for Rate of Burning and/or

Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2005; TIA 2005) National Electrical Code

INTERIOR SIGNAGE 10 14 02 - 2

1.02 SUBMITTALS

Government approval is required for all submittals. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

A. Shop Drawings Detail Drawings Drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, shape and thickness of materials, and details of construction. A schedule showing the location, each sign type, and message shall be included.

B. Product Data Installation Manufacturer's descriptive data, catalogs cuts, installation and cleaning instructions.

C. Samples Interior Signage One full size sample of each of the following sign types showing typical quality, workmanship and color. The samples may be installed in the work, provided each sample is identified and location recorded.

a. Directional sign.

b. Standard Room sign.

c. Changeable message strip sign

D. Operation and Maintenance Data Approved Manufacturer's Instructions Protection and Cleaning Six copies of operating instructions outlining the step-by-step procedures required for system operation shall be provided. The instructions shall include simplified diagrams for the system as installed. Six copies of maintenance instructions listing routine procedures, repairs, and guides shall be provided. The instructions shall include the manufacturer's name, model number, service manual, parts list, and brief description of all equipment and their basic operating features.

Each set shall be permanently bound and shall have a hard cover.

The following identification shall be inscribed on the covers:

the words "OPERATING AND MAINTENANCE INSTRUCTIONS", name and location of the facility, name of the Contractor, and contract number.

1.03 GENERAL

Interior signage shall be of the design, detail, sizes, types, and message content shown on the drawings/attachments/signage placement schedule (as applicable), shall conform to the requirements specified, and shall be provided at the locations indicated. Signs shall be complete with lettering, framing as detailed and related components for a complete installation. Signage shall be obtained from a single manufacturer with edges and corners of finished letterforms and graphics true and clean. Recyclable materials shall conform to EPA requirements in accordance with Section 01 62 35 RECYCLED / RECOVERED

MATERIALS.

INTERIOR SIGNAGE 10 14 02 - 3

1.04 QUALIFICATIONS

Signs, plaques, and dimensional letters shall be the standard product of a manufacturer regularly engaged in the manufacture of such products and shall essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening.

1.05 DELIVERY AND STORAGE

Materials shall be packaged to prevent damage and deterioration during shipment, handling, storage and installation. Product shall be delivered to the jobsite in manufacturer's original packaging and stored in a clean, dry area in accordance with manufacturer's instructions.

1.06 EXTRA STOCK

The Contractor shall provide ten extra frames and extra stock of the following: ten blank plates of each color and size for sign types _____. _____ pressure-sensitive letters in each color and size for sign type _____. 100 changeable message strips for sign type _____.

PART 2 - PRODUCTS

2.01 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM

A. Standard Room Signs

Signs shall consist of acrylic plastic 0.080 inch thickness minimum conforming to ANSI Z97.1][laminated thermosetting Type MP plastic (three-ply melamine plastic laminate with phenolic core)][6063-T5 extruded aluminum in accordance with ASTM B 221M ASTM B 221 and ASTM B 209M ASTM B 209 and shall conform to the following:

Frames shall be aluminum wood molded acrylic. Frames shall be 1/4 inch wide.

End caps shall be aluminum wood molded acrylic with round square style corners.

Units shall be frameless. Corners of signs shall be squared rounded to 10 13 19 mm 3/8 1/2 3/4 inch radius.

B. Changeable Message Strip Signs Changeable message strip signs shall be of same construction as standard room signs to include a clear sleeve that will accept a paper or plastic insert identifying changeable text.

The insert shall be prepared die-cut vinyl letters applied to 0.38 mm 0.015 inch rigid vinyl film dry transfer letters applied to paper card stock typeset message photographically enlarged to size and mounted on paper card stock typewritten message photographically enlarged or used at actual size. Furnish paper and software for creating text and symbols for IBM compatible Macintosh computers for Owner production of paper inserts after project completion. Sliding inserts or slide knobs that slide horizontally exposing different graphic information shall be provided as identified in the signage placement schedule and drawings attachments.

C. Type of Mounting For Signs Extruded aluminum brackets shall be furnished for hanging, projecting, and double-sided signs. Mounting for framed, hanging, and projecting signs shall be by mechanical fasteners.

Surface mounted signs shall be mounted with 1.6 mm 1/16 inch thick vinyl foam tape countersunk mounting holes in plaques and mounting screws magnetic tape silicone adhesive fabricated from materials that are not corrosive to sign material and mounting surface.

INTERIOR SIGNAGE 10 14 02 - 4

D. Graphics Signage graphics for modular signs shall conform to the following:

Subsurface copy: Copy is transferred to the back face of clear acrylic sheeting forming the panel face to produce precisely formed opaque image. This method bonds all sign elements (color, graphics, lettering, braille and substrate) into a single unit. Silkscreened First Surface Copy (non-tactile): Message shall be applied to panel using the silkscreen process.

Silkscreened images shall be executed with photo screens prepared from original art.

Handcut screens will not be accepted. Original art shall be defined as artwork that is a first generation reproduction of the specified art. This method is generally used for mass produced signs. Edges and corners shall be clean. Surface Applied Photopolymer: Integral graphics and braille achieved by photomechanical stratification processes. Photopolymer used for ADA compiant graphics shall be of the type that has a minimum durometer reading of 90. Tactile graphics must be raised 0.8 mm 1/32 inch from the first surface of plaque by photomechanical stratification process. Engraved Copy: Machine engrave letters, numbers, symbols, and other graphics into panel sign on face to produce precisely formed copy and sharp images, incised to uniform depth. Melamine plastic engraving stock used for ADA compliant graphic shall be three-ply lamination contrasting color core meeting ASTM D 635 Graphic Blast Raised Copy: Background is sandblasted to a uniform depth of 0.8 mm 1/32 inch leaving raised text and Braille. Background shall be painted with polyurethane paint.

Embossed: Methods other than sandblasting such as vacuum formed to create ADA compliant projected graphics. Cast Fabricated Solid Aluminum Letters: 3 6 mm 1/8 1/4 inch thick shall be provided and fastened to the message panel with concealed fasteners.

E. Character Proportions and Heights Letters and numbers on indicated signs which do not designate permanent rooms or spaces shall have a width-to-height ratio between 3:5 and 1:1 and a stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers on indicated signs shall be sized according to the viewing distance from which they are to be read. The minimum height is measured using an upper case letter "X". Lower case characters are permitted. Suspended or projected overhead signs shall have a minimum character height of 75 mm 3 inches.

F. Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms) Raised and brailled characters and symbols are only required on signs that designate permanent rooms or spaces, including restrooms and room numbers. They are not required for information or way-finding signs. Raised letters and numbers on signs must protrude 0.8 mm 1/32 inch upper case, sans serif or simple serif type and shall be accompanied with Grade 2 Braille.

Raised characters shall be at least 16 mm 5/8 inch in height, but no higher than 50 mm 2 inches. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. The border dimension of the pictogram shall be 152 mm 6 inches minimum in height. Indicated accessible facilities shall use the international symbol of accessibility.

2.02 BUILDING DIRECTORIES

Building directories shall be lobby directories or floor directories, and shall be provided with a changeable directory listing consisting of the areas, offices and personnel located within the facility. Dimensions, details, and materials of sign and message content shall be as shown on the [drawings][attachments][and signage placement schedule].

A. Header Panel Header panel shall have background metal to match frame and shall have raised letters be acrylic with raised acrylic letters be ES/MP plastic with raised letters.

INTERIOR SIGNAGE 10 14 02 - 5

B. Doors

1. Door Glazing Door glazing shall be in accordance with ASTM C 1036, Type 1, Class 1, Quality 3, minimum 3 mm 1/8 inch thick clear acrylic sheet 4.8 mm 3/16 inch thick conforming to clear polycarbonate sheet 4.8 mm 3/16 inch thick.

2. Door Construction Extruded aluminum door frame shall be of same finish as surrounding frame. Corners shall be mitered, reinforced, welded, and assembled with concealed fasteners. Hinges shall be standard with the manufacturer, in finish to match frames and trim. Glazing shall be set in frame with resilient glazing channels.

3. Door Locks Door locks shall be manufacturer's standard, and shall be keyed alike.

C. Fabrication Extruded aluminum frames and trim shall be assembled with corners reinforced welded and mitered to a hairline fit, with no exposed fasteners.

D. Illuminated Units Illuminated directory units shall have concealed internal top back lighting with rapid start fluorescent tube lamp, internal wiring, and lead at wire for connection. Electrical work shall comply with NFPA 70 and shall be UL or FM listed.

E. Negative Graphics Directory System Directory shall consist of internally illuminated unit with backlit photo negative directory strips and a black background. Unit shall have a tinted tempered safety solar glass door. Design of unit shall be as shown.

1. Construction The directory shall be constructed of an aluminum [100] [150] mm [4] [6] inch deep frame with satin black dark bronze anodized finish. Unit shall be semi fully recessed pedestal mounted. Unit shall have a 75 mm 3 inch high header lettering as shown. Unit shall have a

9.3 mm 3/8 inch face door frame with concealed hinges and locking system. Door frame shall be aluminum with satin black dark bronzesolid polished satin chrome plated brass solid architectural bronze.

2. Message Strips Message strips shall be photo negative type updatable by user with book reordering and with 7 to 10 day delivery. Message strips shall be 9.3 x 87 175 275 mm 3/8 x 3.5 7 11 inches 12.5 x 175 275 mm ½ x 7 11 inches.

F. Changeable Letter/Message Strip Directory System Directory shall consist of an internally illuminated a non-illuminated unit with step or groove, laser or rotary engraved removable name strips felt grooved for changeable letters cast vinyl to receive molded changeable letter tiles laminated plastic magnetic back message strips.

Design of unit shall be as shown in the drawings.

1. Construction

INTERIOR SIGNAGE 10 14 02 - 6

The directory shall be constructed of an aluminum 50 mm 2 inch deep frame with satin black dark bronze anodized finish. Unit shall be surface semi fully recessed pedestal mounted. Unit shall have a 75 mm 3 inch high header with lettering as shown. Unit shall have a 9.3 mm 3/8 inch face concealed hinge door and locking system lift off frame with tempered safety glass fixed frame. Door frame shall be aluminum with satin black dark bronze solid polished satin chrome plated brass solid architectural bronze.

2. Message Strips Namestrips shall be updatable by user with coupon book reordering and with 5 to 7 day delivery. Namestrips shall be acrylic sized per manufacturer's standard. Namestrips shall be felt grooved background with changeable upper and lower case Helvetica Medium letters.

Tabbed vinyl letters and numbers shall be furnished in accordance with the drawings and schedule.

G. Touchscreen Electronic Directory System Touchscreen electronic directory system shall be a complete turnkey system consisting of touchscreen monitor, processor, and update terminal with software connected through a telephone network or local area network (LAN). The system shall be in compliance with the layout and number shown. Electrical equipment shall be UL listed and shall comply with NFPA 70. Unit shall be [free-standing][wall mounted].

1. Directory Unit Directory unit shall consist of 1 350 400 mm 14 16 inch touchscreen monitor and membrane keypad with alphabetic 28 alphanumeric 38 alphabetic braille 30 keys. Screen resolution shall be SVGA 800 x 600 1280 x 1024. Monitor shall be full color. Processor shall be Pentium 75 or better with sound peripherals and have a listing capacity of 96,000 1,000,000 items. Directory unit shall be of design and finishes as shown.

2. Update Terminal Update terminal unit shall consist of a 300 350 mm 12 1 inch color monitor with 84 101 key keypad. Unit shall have a 132 column report printer. Unit shall include a Pentium 75 or better PC processor with floppy disk from update terminal to each directory. System shall include network from update to each directory] [and] [network from mainframe to update terminal to each directory. Communications shall be over a telephone network or a LAN.

2.03 METAL PLAQUES

A. Cast Metal Plaques

1. Fabrication Cast metal plaques shall have the logo, emblem and artwork cast in the bas relief flat relief technique. Plaques shall be fabricated from prime aluminum bronze yellow brass.

2. Border Border shall be flat band plain edge bevel custom ornamental.

3. Background Background texture shall be leather fine pebble.

4. Mounting Mounting shall be concealed rosettes and anchors rosettes and toggle bolts invisible.

5. Finish

INTERIOR SIGNAGE 10 14 02 - 7

Finishes shall consist of aluminum light colored sandblasted background. Letters shall be satin polished and entire plaque shall be sprayed with two coats of clear lacquer aluminum with background sprayed dark gunmetal colored lacquer. Letters shall be satin polished and entire plaque sprayed with two coats clear lacquer bronze with dark finish oxidized background. Letters shall be satin polished and entire plaque sprayed with two coats of clear lacquer aluminum bronze with background sprayed with standard color. Letters shall be satin polished.

B. Chemically Etched Metal Plaques

1. Fabrication Plaque shall be chemically single - double - etched one-piece brass bronze zinc magnesium

0.8128 1.6256 3.175 6.35 mm 0.032 0.064 0.125 0.250 inch thick.

2. Finish Single-etched raised areas shall be in gold-tone silver-tone bronze-tone finish and recessed areas shall be colorfilled. Double-etched raised areas shall be gold-tone silver-tone and recessed textured areas shall be gold-tone silver-tone colorfilled.

C. Frost and Surface Oxidized Plaques

1. Fabrication Plaque shall be frosted and surface oxidized one-piece anodized aluminum brass bronze stainless steel 1.02 3.175 mm 0.040 0.125 inch thick.

2. Finish Material finish shall be satin polished. Frosted areas shall be oxidized black for aluminum or stainless steel or black or brown, for brass or bronze.

2.04 DIMENSIONAL BUILDING LETTERS

A. Fabrication

Letters shall be fabricated from cast aluminum cast bronze 2.29 3.17 mm 0.090 0.125 inch aluminum sheet extruded aluminum injection molded plastic. Letters shall be cleaned by chemical etching or cleaned ultrasonically in a special degreasing bath. Letters shall be packaged for protection until installation.

B. Typeface Typeface shall be helvetica medium.

C. Size Letter size shall be _____.

D. Finish Anodized aluminum Baked enamel or two-component acrylic polyurethane Polished Oxidized bronze with clear coat finish shall be provided.

E. Mounting Threaded studs Steel U-bracket, cap screws, and expansion bolts of number and size recommended by manufacturer, shall be supplied for concealed anchorage. Letters which project from the mounting surface shall have stud spacer sleeves. Letters, studs, and sleeves shall be of the same material. Templates for mounting shall be supplied.

INTERIOR SIGNAGE 10 14 02 - 8

2.05 PRESSURE SENSITIVE LETTERS

Ensure that edges and corners of finished letterforms and graphics are true and clean. Do not use letterforms and graphics with rounded positive or negative corners, nicked, cut, or ragged edges.

A. Typeface Helvetica medium.

B. Size As indicated.

2.06 ALUMINUM ALLOY PRODUCTS

Aluminum extrusions shall be at least 3 mm 1/8 inch thick, and aluminum plate or sheet shall be at least 1.3 mm 0.0508 inch thick. Extrusions shall conform to ASTM B 221M ASTM B 221; plate and sheet shall conform to ASTM B 209M ASTM B 209. Where anodic coatings are specified, alloy shall conform to AA PK-1 alloy designation 514.0. Exposed anodized aluminum finishes shall be as shown. Welding for aluminum products shall conform to AWS D1.2/D1.2M.

2.07 ANODIC COATING

Anodized finish shall conform to AA DAF-45 as follows:

Clear (natural) designation AA-M10-C22-A31, Architectural Class II 0.010 mm 0.4 mil or thicker. Integral color anodized designation AA-M10-C22-A32, Architectural Class 0.010 to

0.018 mm 0.4 to 0.7 mil. Electrolytically deposited color-anodized designation AA-M10-C22- A34, Architectural Class II 0.010 to 0.018 mm 0.4 to 0.7 mil.

2.08 ORGANIC COATING

Organic coating shall conform to AAMA 2604, with total dry film thickness not less than

0.030 mm 1.2 mils.

2.09 FABRICATION AND MANUFACTURE

A. Factory Workmanship

Holes for bolts and screws shall be drilled or punched. Drilling and punching shall produce clean, true lines and surfaces. Exposed surfaces of work shall have a smooth finish and exposed riveting shall be flush. Fastenings shall be concealed where practicable.

B. Dissimilar Materials Where dissimilar metals are in contact, the surfaces will be protected to prevent galvanic or corrosive action.

2.10 COLOR, FINISH, AND CONTRAST

Color shall be in accordance with Section 09 06 90 COLOR SCHEDULE as indicated on the drawings. Finish of all signs shall be eggshell, matte, or other non-glare finish as required in handicapped-accessible buildings.

PART 3 - EXECUTION

3.01 INSTALLATION

Signs shall be installed plumb and true and in accordance with approved manufacturer's instructions at locations shown on the detail drawings schedule below attachments.

INTERIOR SIGNAGE 10 14 02 - 9

Mounting height shall be 60 inch above the finish floor to the centerline of the sign. Distance from edge of door frame to edge of sign shall be 2” on the latch side of door. Required blocking shall be installed. Signs shall be installed on the wall adjacent to the latch side of the door. Where there is no wall space to the latch side of the door, including at double leaf doors, signs shall be placed on the nearest adjacent wall. Mounting location for such signage shall be so that a person may approach within 3 inches of signage without encountering protruding objects or standing within the swing of a door. Signs shall not be placed on doors. Signs shall not be installed on any surface until finishes on such surfaces have been installed and dryed. Signs installed on glass surfaces shall be installed with matching blank back-up plates in accordance with manufacturer's instructions.

A. Mechanical Fastening & Anchorage

1. All anchorage shall be in accordance with approved manufacturer's instructions and shall be mechanically fastened. Anchorage not otherwise specified or shown shall include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete;

toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood. Exposed anchor and fastener materials shall be compatible with metal to which applied and shall have matching color and finish. Signs mounted to painted gypsum board surfaces shall be removable for painting maintenance. Signs mounted to lay-in ceiling grids shall be mounted with clip connections to ceiling grid tees. Adhesively attached sign systems will not be accepted.

B. Protection and Cleaning

The work shall be protected against damage during construction. Hardware and electrical equipment shall be adjusted for proper operation. Glass, frames, and other sign surfaces shall be cleaned at completion of sign installation in accordance with the manufacturer's approved instructions.

3.02 SIGN SCHEDULE & TEXT AND GRAPHIC SYMBOL VERIFICATION

A. Contractor shall meet with user and base civil engineering to determine exact text and graphic symbols for each sign and type of sign. All doors interior and exterior and definable spaces shall receive signage. Each lobby area and way point of a facility shall have a directory board and directional signage as required to guide visitors effectively though the facility.

B. Size of all signs shall be dictated by the text size plus 1” on all sides

101 (1-1/4” TEXT)

G R A D E 2 B R A I L L E

PRIVATE OFFICE TITLE (3/4" TEXT)

G R A D E 2 B R A I L L E

NAME AND TITLE OF OCCUPANT (3/4" TEXT)

C H A N G E A B L E T E X T

INTERIOR SIGNAGE 10 14 02 - 10

102 (1-1/4” TEXT)

G R A D E 2 B R A I L L E

PRIVATE OFFICE TITLE (3/4" TEXT)

G R A D E 2 B R A I L L E

103 (1-1/4” TEXT)

PRIVATE DORM ROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

114 (1-1/4” TEXT)

PRIVATE DORM ROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

119 (1-1/4” TEXT)

OPEN OFFICE AREA (3/4" TEXT)

121 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 11

OPEN OFFICE AREA

WITH LONG TITLE (3/4" TEXT)

122 (1-1/4” TEXT)

COMMUNICATIONS CLOSET (3/4" TEXT)

123 (1-1/4” TEXT)

RESTROOM (3/4" TEXT)

(MALE, FEMALE & HC SYMBOLS)

126 (1-1/4” TEXT)

MECHANICAL ROOM (3/4" TEXT)

127 (1-1/4” TEXT)

RESTROOM (3/4" TEXT)

(MALE, FEMALE & HC SYMBOLS)

INTERIOR SIGNAGE 10 14 02 - 12

132 (1-1/4” TEXT)

ROOKIE ROOM (3/4" TEXT)

134 (1-1/4” TEXT)

PHYSICAL FITNESS ROOM (3/4" TEXT)

136 (1-1/4” TEXT)

TRAINING CENTER (3/4" TEXT)

137 (1-1/4” TEXT)

AUDIO / VISUAL STORAGE (3/4" TEXT)

138 (1-1/4” TEXT)

TESTING CENTER (3/4" TEXT)

INTERIOR SIGNAGE 10 14 02 - 13

139 (1-1/4” TEXT)

RECREATION ROOM (3/4" TEXT)

140 (1-1/4” TEXT)

DAY / TV ROOM (3/4" TEXT)

143 (1-1/4” TEXT)

FAMILY CENTER (3/4" TEXT)

144 (1-1/4” TEXT)

DINING (3/4" TEXT)

145 (1-1/4” TEXT)

KITCHEN (3/4" TEXT)

INTERIOR SIGNAGE 10 14 02 - 14

149 (1-1/4” TEXT)

G R A D E 2 B R A I L L E

JANITORIAL CLOSET (3/4" TEXT)

152 (1-1/4” TEXT)

SAUNA (3/4" TEXT)

153 (1-1/4” TEXT)

WOMEN’S RESTROOM / LOCKER

ROOM (3/4" TEXT)

(FEMALE & HC SYMBOLS)

155 (1-1/4” TEXT)

MEN’S RESTROOM / LOCKER ROOM (3/4"

TEXT)

(MALE & HC SYMBOLS)

156 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

INTERIOR SIGNAGE 10 14 02 - 15

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

B-SHIFT (3/4" TEXT)

157 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

158 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

159 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 16

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

160 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

161 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

162 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

INTERIOR SIGNAGE 10 14 02 - 17

163 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

164 (1-1/4” TEXT)

STATION CAPTAIN (3/4" TEXT)

165 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

INTERIOR SIGNAGE 10 14 02 - 18

166 (1-1/4” TEXT)

G R A D E 2 B R A I L L E

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

167 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

168 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

169 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 19

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

170 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

171 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

172 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 20

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

173 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

174 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

175 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 21

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

176 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

177 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

178 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 22

C H A N G E A B L E T E X T

179 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

180 (1-1/4” TEXT)

PRIVATE BEDROOM (3/4" TEXT)

G R A D E 2 B R A I L L E

A-SHIFT (3/4" TEXT)

C H A N G E A B L E T E X T

183 (1-1/4” TEXT)

DISINFECTION ROOM (3/4" TEXT)

INTERIOR SIGNAGE 10 14 02 - 23

184 (1-1/4” TEXT)

G R A D E 2 B R A I L L E

JANITORIAL CLOSET (3/4" TEXT)

185 (1-1/4” TEXT)

LOCKERS (3/4" TEXT)

186 (1-1/4” TEXT)

LAUNDRY (3/4" TEXT)

193 (1-1/4” TEXT)

FIRE HOSE STORAGE (3/4" TEXT)

194 (1-1/4” TEXT)

SCBA MAINTENANCE (3/4" TEXT)

195 (1-1/4” TEXT)

INTERIOR SIGNAGE 10 14 02 - 24

COMPRESSOR ROOM (3/4" TEXT)

196 (1-1/4” TEXT)

VEHICLE MAINTENANCE OFFICE (3/4"

TEXT)

197 (1-1/4” TEXT)

VEHICLE MAINTENANCE WORK

CENTER (3/4" TEXT)

198 (1-1/4” TEXT)

FIRE EXTINGUISHER MAINTENANCE

(3/4" TEXT)

G R A D E 2 B R A I L L E

TSGT JOSEPH LANG (3/4" TEXT)

199 (1-1/4” TEXT)

FIRE EXTINGUISHER STORAGE (3/4" TEXT)

INTERIOR SIGNAGE 10 14 02 - 25

200 (1-1/4” TEXT)

G R A D E 2 B R A I L L E

AGENT STORAGE (3/4" TEXT)

END OF SECTION – INTERIOR SIGNAGE

TEMPORARY CONSTRUCTION FACILITIES 01500 - 26

DIVISION 10 – SPECIALTIES
SECTION 10 14 02 – INTERIOR SIGNAGE (10440)
PART 1 - GENERAL
1.01 REFERENCES
1.02 SUBMITTALS
A. Shop Drawings
B. Product Data
C. Samples Interior Signage
D. Operation and Maintenance Data
1.03 GENERAL
1.04 QUALIFICATIONS
1.05 DELIVERY AND STORAGE
1.06 EXTRA STOCK
PART 2 - PRODUCTS
2.01 ROOM IDENTIFICATION/DIRECTIONAL SIGNAGE SYSTEM
A. Standard Room Signs
B. Changeable Message Strip Signs
C. Type of Mounting For Signs
D. Graphics
E. Character Proportions and Heights
F. Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms) Raised and brailled characters and symbols are only required on signs that designate permanent rooms or spaces, including restrooms and room numbers. They are not required fo...
2.02 BUILDING DIRECTORIES
A. Header Panel
B. Doors
1. Door Glazing
2. Door Construction
3. Door Locks
C. Fabrication
D. Illuminated Units
E. Negative Graphics Directory System
1. Construction
2. Message Strips
F. Changeable Letter/Message Strip Directory System
1. Construction
2. Message Strips
G. Touchscreen Electronic Directory System
1. Directory Unit
2. Update Terminal
2.03 METAL PLAQUES
A. Cast Metal Plaques
1. Fabrication
2. Border
3. Background
4. Mounting
5. Finish
B. Chemically Etched Metal Plaques
1. Fabrication
2. Finish
C. Frost and Surface Oxidized Plaques
1. Fabrication
2. Finish
2.04 DIMENSIONAL BUILDING LETTERS
A. Fabrication
B. Typeface
C. Size
D. Finish
E. Mounting
2.05 PRESSURE SENSITIVE LETTERS
A. Typeface
B. Size
2.06 ALUMINUM ALLOY PRODUCTS
2.07 ANODIC COATING
2.08 ORGANIC COATING
2.09 FABRICATION AND MANUFACTURE
A. Factory Workmanship
B. Dissimilar Materials

2.10 COLOR, FINISH, AND CONTRAST

PART 3 - EXECUTION
3.01 INSTALLATION
A. Mechanical Fastening & Anchorage
B. Protection and Cleaning
3.02 SIGN SCHEDULE & TEXT AND GRAPHIC SYMBOL VERIFICATION
A. Contractor shall meet with user and base civil engineering to determine exact text and graphic symbols for each sign and type of sign. All doors interior and exterior and definable spaces shall receive signage. Each lobby area and way point of...
B. Size of all signs shall be dictated by the text size plus 1” on all sides

File details come from the government source that posted it. Updated .