Attachment 19 - 09 06 89 TYPICAL FINISH SCHEDULE.pdf
PDF 95 KB Posted
- Attached to
- Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR Federal contract opportunity
- Solicitation number
- FA446021R0009
About this file
This document provides a typical finish schedule for a federal construction project. It specifies that corridor, entryway, vestibule and lobby walls will be finished with Type II vinyl wall covering, while private and commander's offices, conference and meeting rooms, and training/classrooms will feature both Type II and Type IIc vinyl wall coverings. Most rooms will have carpet flooring, porcelain ceramic tile in restrooms, kitchens and showers, and drop ceilings of various acoustic ceiling tiles. It also defines abbreviations for each finish material and references related specification sections.
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYPICAL FINISH SCHEDULE 09 06 89 - 1
SECTION 09 06 89 – TYPICAL FINISH SCHEDULE
PART 1 - GENERAL
1.01 FINISH SCHEDULE
A. Unless otherwise noted on the drawings or in the specifications the following typical finish schedule shall be followed for this project.
TYPICAL FINISH SCHEDULE
ROOM # WALLS FLOOR WALL
BASE CEILING REMARKS
101 CORRIDORS VWC-B CPT-A CB ACT-A CORNER GUARDS &
POSSIBLY WALL GUARDS
102 ENTRIES VWC-B PCT PCTB ACT-A CORNER GUARDS
103 VESTIBULES VWC-B PCT PCTB ACT-A
104 LOBBIES VWC-B CPT-A CB ACT-A
105 PRIVATE
OFFICES VWC-A CPT-A CB ACT-B
COMMANDERS
OFFICES
VWC-A CPT-A CB ACT-B
TWO PIECE OAK OR BIRCH
CHAIR RAIL TO MATCH
INTERIOR DOOR WOOD
COLOR AND GRAIN
107 RESTROOMS CT PCT CTB ACT-C Durock substrate with 9235 Laticrete membrane
108 OPEN OFFICE
AREAS VWC-A CPT-A CB ACT-A
109 STORAGE
CLOSETS PAINT CPT-A CB ACT-A or
PAINT
110 CONFERENCE
ROOMS
VWC-A
VWC-C
CPT-A CB ACT-B
VWC COVERED GYP BD
PERIMETER CEILING SOFFIT.
TWO PIECE OAK OR BIRCH
CHAIR RAIL TO MATCH
INTERIOR DOORS WOOD
COLOR AND GRAIN
111 MEETING
ROOMS
VWC-A
VWC-C
CPT-A CB ACT-B GYP BD PERIMETER CEILING
SOFFIT
112 TRAINING/
CLASSROOMS
VWC-A
VWC-C
CPT-A CB ACT-B
113 TOOL ROOMS PAINT VCT VWB ACT-A
114 MECHANICAL
ROOMS PAINT SC PCTB
PAINT
OR ACT-
A
TYPICAL FINISH SCHEDULE 09 06 89 - 2
TYPICAL FINISH SCHEDULE
ROOM # WALLS FLOOR WALL
BASE CEILING REMARKS
COMMUNICATION
CLOSETS
PAINT SC VWB
PAINT
116 TELEPHONE
CLOSETS PAINT SC VWB
PAINT
117 KITCHENS /
BREAK ROOMS CT PCT CTB ACT-C Durock substrate with 9235
Laticrete membrane
118 SLEEPING
QUARTERS VWC-A CPT-A CB
ACT-B
OR
PAINT
119 SHOWERS &
SAUNAS CT PCT PCTB ACT-C Durock substrate with 9235
Laticrete membrane
120 DAY ROOMS
VWC-A
VWC-C
CPT-A CB ACT-B
121 LAUNDRY CT PCT PCTB ACT-C Durock substrate with 9235 Laticrete membrane
122 OTHERS VWC-A CPT-A CB ACT-A
B. LEGEND
1. PAINT – Prep wall or ceiling to Level 5, prime coat and two coat paint SEE SECTION 09
90 00 PAINTING & COATING
2. ACT-A – 2’ x 2’ sound controlling bright white fine fissure tegular edge 3/4” ceiling tile and grid system SEE SECTION 09 51 00 ACOUSTICAL CEILINGS
3. ACT-B – sound controlling and absorbing 2’ x 2’ bright white fine fissure tegular edge 3/4” ceiling tile and grid system SEE SECTION 09 51 00 ACOUSTICAL CEILINGS
4. ACT-C – washable and moisture resistant 2’ x 2’ bright white fine fissure tegular edge 3/4” ceiling tile and grid system SEE SECTION 09 51 00 ACOUSTICAL CEILINGS
5. CPT-A – Direct glue carpeting SEE SECTION 09 68 00 CARPET
6. CPT-B – Direct glue carpeting SEE SECTION 09 68 00 CARPET
7. CPT-C – Direct glue carpeting SEE SECTION 09 68 00 CARPET
8. PCT – Non-skid porcelain ceramic floor tile SEE SECTION 09 30 00 CERAMIC TILE
9. PCTB – Bullnose coved toe porcelain ceramic wall base SEE SECTION 09 30 00
CERAMIC TILE
10. CT – Glazed face wall tile SEE SECTION 09 30 00 CERAMIC TILE
11. CTB – Glazed face coved toe wall tile base SEE SECTION 09 30 00 CERAMIC TILE
TYPICAL FINISH SCHEDULE 09 06 89 - 3
12. VWC-A – TYPE II vinyl wall covering SEE SECTION 09 72 00 WALL COVERINGS
13. VWC-B – TYPE II vinyl wall covering stain resistant SEE SECTION 09 72 00 WALL
COVERINGS
14. VWC-C – TYPE II vinyl wall covering framed dry-erase and project screen SEE
SECTION 09 72 00 WALL COVERINGS
15. CB – Seamed edge roll stock carpet wall base to match CARPET SEE SECTION 09 68
00 CARPET
16. VCT – 1/8” thick vinyl composition tile SEE SECTION 09 65 00 RESILIENT FLOORING
17. VWB – 1/8” thick Vinyl Wall Base SEE SECTION 09 65 00 RESILIENT FLOORING
18. SC – Sealed concrete
19. CORNER GUARDS - SEE SECTION 10 23 13 WALL AND CORNER GUARDS
20. ETR – Existing To Remain
PART 2 - PRODUCTS – NOT USED
PART 3 - EXECUTION – NOT USED
END OF SECTION – TYPICAL FINISH SCHEDULE
FINISH SCHEDULE 09 00 01 - 4
| SECTION 09 06 89 – TYPICAL FINISH SCHEDULE |
| PART 1 - GENERAL |
| 1.01 FINISH SCHEDULE |
| A. Unless otherwise noted on the drawings or in the specifications the following typical finish schedule shall be followed for this project. |
| B. LEGEND |
| 1. PAINT – Prep wall or ceiling to Level 5, prime coat and two coat paint SEE SECTION 09 90 00 PAINTING & COATING |
| 2. ACT-A – 2’ x 2’ sound controlling bright white fine fissure tegular edge 3/4” ceiling tile and grid system SEE SECTION 09 51 00 ACOUSTICAL CEILINGS |
| 3. ACT-B – sound controlling and absorbing 2’ x 2’ bright white fine fissure tegular edge 3/4” ceiling tile and grid system SEE SECTION 09 51 00 ACOUSTICAL CEILINGS |
| 4. ACT-C – washable and moisture resistant 2’ x 2’ bright white fine fissure tegular edge 3/4” ceiling tile and grid system SEE SECTION 09 51 00 ACOUSTICAL CEILINGS |
| 5. CPT-A – Direct glue carpeting SEE SECTION 09 68 00 CARPET |
| 6. CPT-B – Direct glue carpeting SEE SECTION 09 68 00 CARPET |
| 7. CPT-C – Direct glue carpeting SEE SECTION 09 68 00 CARPET |
| 8. PCT – Non-skid porcelain ceramic floor tile SEE SECTION 09 30 00 CERAMIC TILE |
| 9. PCTB – Bullnose coved toe porcelain ceramic wall base SEE SECTION 09 30 00 CERAMIC TILE |
| 10. CT – Glazed face wall tile SEE SECTION 09 30 00 CERAMIC TILE |
| 11. CTB – Glazed face coved toe wall tile base SEE SECTION 09 30 00 CERAMIC TILE |
| 12. VWC-A – TYPE II vinyl wall covering SEE SECTION 09 72 00 WALL COVERINGS |
| 13. VWC-B – TYPE II vinyl wall covering stain resistant SEE SECTION 09 72 00 WALL COVERINGS |
| 14. VWC-C – TYPE II vinyl wall covering framed dry-erase and project screen SEE SECTION 09 72 00 WALL COVERINGS |
| 15. CB – Seamed edge roll stock carpet wall base to match CARPET SEE SECTION 09 68 00 CARPET |
| 16. VCT – 1/8” thick vinyl composition tile SEE SECTION 09 65 00 RESILIENT FLOORING |
| 17. VWB – 1/8” thick Vinyl Wall Base SEE SECTION 09 65 00 RESILIENT FLOORING |
| 18. SC – Sealed concrete |
| 19. CORNER GUARDS - SEE SECTION 10 23 13 WALL AND CORNER GUARDS |
| 20. ETR – Existing To Remain |
| PART 2 - PRODUCTS – NOT USED |
| PART 3 - EXECUTION – NOT USED |