Attachment 17 - 01 57 22 TREE PRESERVATION.pdf

PDF 97 KB Posted

Attached to
Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR Federal contract opportunity
Solicitation number
FA446021R0009
Issued by
Department of the Air Force Air Mobility Command

About this file

This solicitation requests proposals for an indefinite-delivery indefinite-quantity multiple award construction contract to provide general construction services at Little Rock Air Force Base in Arkansas. Work under individual task orders may include new construction, repair, alteration, demolition, and design-build services for facilities such as administrative buildings, industrial structures, maintenance buildings, warehouses, communications installations, personnel support structures, recreation facilities, lodging, medical buildings, training buildings, ranges, roads, and utilities including jet fuel systems. In-house design capabilities or access to designers is required to support design-build project delivery. The Department of the Air Force seeks to award multiple contracts for task orders that will involve sustainment, restoration, and modernization projects over an extended period of performance.

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR, newest first.
File Type Posted
Amend 05 -Updated Attachment 30 - Past Performance Package..docx DOCX document
Amend 05 -Attachment 32 Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Amend 05 -Attachment 13 - Statement of Work for MACC Rev 1.pdf PDF
Amend 05 -Solicitation Amendment - FA446021R00090005.pdf PDF
Amend 05 -Attachment 38 Questions and Answers after 3rd Site visit.pdf PDF
Solicitation Amendment - FA446021R00090004.pdf PDF
Amend 04 -Attachment 32 Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Amend 04 -Attachment 37 - 2nd Site Visit Sign-in-Sheet 6-23-21.pdf PDF
Solicitation Amendment FA446021R00090004 SF 30.pdf PDF
Amend 04 -Attachment 36 - Site Visit Sign-in-Sheet 6-15-21.pdf PDF
Solicitation Amendment FA446021R00090003 SF 30.pdf PDF
Attachment 32 Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Attachment 34 - PPI Tool Download Instructions.pdf PDF
Updated Attachment 30 - Past Performance Package.docx DOCX document
Solicitation Amendment FA446021R00090002 SF 30.pdf PDF
Solicitation Amendment FA446021R00090001 SF 30.pdf PDF
Attachment 32 - Convert Mission Planning Cell B-380 Seed Project Amend 1.zip ZIP file
Amend 0001-Solicitation - FA446021R0009 Rel.pdf PDF
Attachment 32 - Convert Mission Planning Cell B-380 (Seed Project).zip ZIP file
Attachment 29 - Maintainability Review Checklist FORM - Design Team.docx DOCX document
Attachment 27 - EZSource PresentPast Performance Relevancy Table .docx DOCX document
Attachment 26 - Design Review Checklist including constructability review 2013 07 30.docx DOCX document
Attachment 20 - 10 14 02 INTERIOR SIGNAGE.pdf PDF
Attachment 18 - 08 71 00 DOOR HARDWARE.pdf PDF
Attachment 16 - 00 00 02 LRAFB SPECIFICATIONS FORMAT STANDARD.pdf PDF
Attachment 9 - LRAFB Architectural Design Guide Supplement.pdf PDF
Attachment 7 - LRAFB Mechanical Design Criteria.pdf PDF
Attachment 30 - Past Performance Package.docx DOCX document
Attachment 25 - 28 31 00 FIRE DETECTION AND ALARM SYSTEMS.pdf PDF
Attachment 24 - 27 51 16 BUILDING MASS NOTIFICATION SYSTEM.pdf PDF
Attachment 19 - 09 06 89 TYPICAL FINISH SCHEDULE.pdf PDF
Attachment 14 - ETL 07-04 AIR FORCE CARPET STANDARD.pdf PDF
Attachment 13 - Statement of Work for MACC.pdf PDF
Attachment 11 - LRAFB Arch Design Guide Supplement 6 Aug 20.pdf PDF
Attachment 10 - LRAFB Arch Compatibility Guide.pdf PDF
Attachment 8 - LRAFB Telecommunications Systems Design.pdf PDF
Attachment 3 - CandD Report.pdf PDF
Attachment 2 - Environmental MOA.pdf PDF
Attachment 28 - Financial Institution Reference Sheet.pdf PDF
Attachment 23 - 27 20 00 COMPUTER-TELEPHONE SYSTEMS May 2010.pdf PDF
Attachment 12 - Scheduled Government Furnished Property.pdf PDF
Attachment 1 - EMIS Instruction Guide.pdf PDF
Attachment 22 - 26 05 04 RACEWAYS.pdf PDF
Attachment 33- SubKTR_Consent_Form.pdf PDF
Attachment 21 - 10 44 16 FIRE EXTINGUISHERS - CABINETS.pdf PDF
Attachment 15 - UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings.pdf PDF
Attachment 6 - LRAFB Electrical Design Standards.pdf PDF
Attachment 5 - LRAFB Information.pdf PDF
Attachment 4 - LRAFB Civil Design Criteria.pdf PDF
Released Solicitation - FA446021R0009.pdf PDF
Show all 50

Multiple Award Construction Contract (MACC)/Indefinite-Delivery Indefinite-Quantity (IDIQ) Little Rock AFB, AR has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TREE PRESERVATION 01 57 22 - 1

SECTION 01 57 22 – TREE PRESERVATION

PART 1 - GENERAL

1.01 TREE PRESERVATION

A. Tree preservation is a proactive process that seeks to make as little impact as possible on existing trees and to mitigate the effects of construction.

1.02 REFERENCES

Tree City USA Bulletin # 24 Web Link: http://www.arborday.org/programs/treecitybulletinsbrowse.cfm

PART 2 - PRODUCTS (Not Used)

PART 3 - EXECUTION

3.01 PROCEDURES TO PROTECT TREES

A. Contractor shall protect as much of the root zones as possible. Establish and maintain a highly visible physical barrier five feet outside of the drip line to keep equipment and materials out. The most significant roots are in the top 18 to 24 inches of soil. Roots may extend two to three times the length of the branches. An orange mesh fencing barrier shall be used to separate construction activity from sensitive roots. Ensure these areas are respected by all parties working on the site.

B. Use wood chips to mulch the root zones of existing trees to remain.

C. Do not trench or change the existing grade in the root zone of an existing tree. If a utility must be routed beneath a tree then horizontal boring must be utilized.

D. Contractor must plan access to the site that will be efficient and protect tree root zones.

E. Contractor shall design parking lots and/or sidewalks to incorporate and protect existing and new trees. Do not use soil sterilants. See Tree City USA Bulletin # 24.

F. Contractor shall not prune existing trees.

G. Contractor shall not fertilize existing trees.

H. Establish approved concrete truck washout areas on site away from protected tree root zones to prevent chemical contamination of soil and vegetation. Contain all run-off on site.

I. Water the entire area beneath the branches with 1 inch of water each week during dry spells during construction.

J. Use signs to identify tree protection zones and alert workers to them. Do not use the trees themselves to support the signs. Do not drive nails or other objects into trees.

K. Contact the Natural Resources Manager, Ms. Dana Hardage at (501) 987-3681,when laying out root protection zones for assistance.

END OF SECTION – TREE PRESERVATION

http://www.arborday.org/programs/treecitybulletinsbrowse.cfm

TREE PRESERVATION 01 57 22 - 2

SECTION 01 57 22 – TREE PRESERVATION
PART 1 - GENERAL
1.01 TREE PRESERVATION
A. Tree preservation is a proactive process that seeks to make as little impact as possible on existing trees and to mitigate the effects of construction.

1.02 REFERENCES

PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION
3.01 PROCEDURES TO PROTECT TREES
A. Contractor shall protect as much of the root zones as possible. Establish and maintain a highly visible physical barrier five feet outside of the drip line to keep equipment and materials out. The most significant roots are in the top 18 to 24...
B. Use wood chips to mulch the root zones of existing trees to remain.
C. Do not trench or change the existing grade in the root zone of an existing tree. If a utility must be routed beneath a tree then horizontal boring must be utilized.
D. Contractor must plan access to the site that will be efficient and protect tree root zones.
E. Contractor shall design parking lots and/or sidewalks to incorporate and protect existing and new trees. Do not use soil sterilants. See Tree City USA Bulletin # 24.
F. Contractor shall not prune existing trees.
G. Contractor shall not fertilize existing trees.
H. Establish approved concrete truck washout areas on site away from protected tree root zones to prevent chemical contamination of soil and vegetation. Contain all run-off on site.
I. Water the entire area beneath the branches with 1 inch of water each week during dry spells during construction.
J. Use signs to identify tree protection zones and alert workers to them. Do not use the trees themselves to support the signs. Do not drive nails or other objects into trees.
K. Contact the Natural Resources Manager, Ms. Dana Hardage at (501) 987-3681,when laying out root protection zones for assistance.

File details come from the government source that posted it. Updated .