This document summarizes a solicitation for the JBER Mini-MACC contract. The solicitation seeks general construction services for multiple facilities projects at Joint Base Elmendorf-Richardson in Alaska. The contract will complement an existing MACC design-build contract by handling smaller projects ranging from 35-95% design completion. Work may include various construction disciplines, and designs will be provided for the contractor to execute. The contract is intended to provide a pool of contractors focused on good performance to receive future projects. The solicitation was issued by the Department of the Air Force Pacific Air Forces.
View the file
Other files for this federal contract opportunity
Show all 42
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Joint Base Elmendorf-Richardson Vol. 1: JBER Elmendorf IFS
31-JANUARY-2019
JOINT BASE ELMENDORF-RICHARDSON
INSTALLATION FACILITIES STANDARDS (IFS)
VOL. 1: JBER ELMENDORF
Installation Elements
Size image to:
170 pixels width x 170 pixels height
Click here to insert image
Site Development
Facilities Exteriors
Facilities Interiors
Installation Elements Site Development Facilities Exteriors Facilities Interiors
APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED
Signature Field
AIR FORCE
INSTALLATION
FACILITIES
STANDARDS
JBER Elmendorf IFS
Table of Contents
A. OVERVIEW
A01. Facility Hierarchy
A02. Facility Quality
A03. Facility Districts
B. INSTALLATION ELEMENTS
B01. Comprehensive Planning
B01.1. Installation Development Plan (IDP) B01.1.1. IFS Component Plan of IDP B01.1.2. Brief History of Base B01.1.3. Future Development
B02. Street Envelope Standards
B02.1. Hierarchy of Streets B02.1.1. Arterial Streets B02.1.2. Collector Streets B02.1.3. Local Streets B02.1.4. Special Routes
B02.2. Hierarchy of Intersections B02.2.1. Arterials B02.2.2. Arterial/Collector B02.2.3. Collectors B02.2.4. Special Intersections B02.2.5. Street Frontage Requirements B02.2.6. Sight Lines
B02.3. Street Elements B02.3.1. Paving B02.3.2. Curb and Gutter B02.3.3. Utility Service Elements B02.3.4. Traffic Signs B02.3.5. Street Lighting B02.3.6. Other
B03. Open Space / Public Space
B03.1. Plazas, Monuments and Static Displays
B03.1.1. Paved Plazas B03.1.2. Sculptures, Markers and Statuary B03.1.3. Static Display of Aircraft
B03.2. Grounds and Perimeters
B03.2.1. Parade Grounds B03.2.2. Parks
B03.2.3. Preserves B03.2.4. Perimeter Fence
C. SITE DEVELOPMENT
C01. Site Design
C01.1. Site Design Considerations
C01.2. Building Orientation
C02. Utilities
C02.1. Utility Components
C03. Parking Areas
C03.1. Configurations and Design C03.1.1. Paving and Striping C03.1.2. Curbing C03.1.3. Internal Islands and Medians
C03.2. Parking Structures
C03.3. Connectivity
C04. Stormwater Management
C04.1. Stormwater Requirements
C05. Sidewalks, Bikeways and Trails
C05.1. Circulation and Paving C05.1.1. Ramps and Stairs C05.1.2. Lighting
C06. Landscape
C06.1. Climate-based Materials C06.1.1. Landscape Design Concept C06.1.2. Xeriscape Design Principles C06.1.3. Minimizing Water Requirements C06.1.4. Plant Material Selection C06.1.5. Water Budgeting (Hydrozones) C06.1.6. Base Entrance Landscaping C06.1.7. Streetscape Landscaping C06.1.8. Pedestrian Circulation Landscaping C06.1.9. Parking Lot Landscaping C06.1.10. Screen/Accent Landscaping C06.1.11. Other
C07. Site Furnishings
C07.1. Furnishings and Elements
Table of contents continued on next page
Table of contents continued
C07.2. Site Furnishings Products, Materials / Color .. 61
C07.2.1. Barbeque Grills C07.2.2. Benches C07.2.3. Bike Racks C07.2.4. Bike Lockers C07.2.5. Bollards C07.2.6. Bus Shelters C07.2.7. Drinking Fountains C07.2.8. Dumpster Enclosures / Gates C07.2.9. Fencing C07.2.10. Flagpoles C07.2.11. Lighting – Landscape / Accent C07.2.12. Litter and Ash Receptacles C07.2.13. Picnic Tables C07.2.14. Planters – Free Standing C07.2.15. Play Equipment C07.2.16. Screen Walls C07.2.17. Tree Grates C07.2.18. Other
C08. Exterior Signs
C08.1. Colors and Types C08.1.1. Materials and Color Specifications C08.1.2. Installation and Gate Identification Signs C08.1.3. Building Identification Signs C08.1.4. Traffic Control Devices (Street Signs) C08.1.5. Directional and Wayfinding Signs C08.1.6. Informational Signs C08.1.7. Motivational Signs C08.1.8. Parking Lot Signs C08.1.9. Regulatory Signs C08.1.10. Other
C09. Lighting
C09.1. Fixtures and Lamping
C09.2. Light Fixture Types
C09.2.1. Street Lighting C09.2.2. Parking Lot Lighting C09.2.3. Lighted Bollards C09.2.4. Sidewalk Lighting C09.2.5. Walls / Stairs Lighting C09.2.6. Other
D. FACILITIES EXTERIORS
D01. Supporting the Mission
D02. Sustainability
D03. Architectural Features
D03.1. Orientation, Massing and Scale
D03.2. Architectural Character
D03.3. Details and Color D03.3.1. Climate-based Data D03.3.2. Natural Ventilation System D03.3.3. Thermal Mass
D03.3.4. Thermal Shading D03.3.5. Renewable Heating/Cooling D03.3.6. Solar Photovoltaic System D03.3.7. Solar Thermal System
D04. Building Entrances
D04.1. Primary Entrances
D04.2. Secondary Entrances
D05. Wall Systems
D05.1. Hierarchy of Materials
D05.2. Layout, Organization and Durability
D05.3. Equipment, Vents and Devices
D05.4 Wall Systems Materials
D05.4.1. Flat Metal Panels D05.4.2. Brick Veneer D05.4.3. Architectural Precast D05.4.4. Stucco Over Sheathing D05.4.5. Curtain Wall D05.4.6. Cast-in Place Concrete D05.4.7. Tilt-up Concrete D05.4.8. Ribbed Metal Sheeting
D05.4.9. EIFS
D05.4.10.GFRC
D05.4.11.Concrete Block D05.4.12. Fiber Cement Siding D05.4.13. Other
D06. Doors and Windows
D06.1. Types
D06.2. Layout and Geometry
D06.3. Glazing and Shading
D06.4. Hardware
D06.5. Doors and Windows Materials D06.5.1. Anodized Aluminum D06.5.2. Hollow Metal D06.5.3. Aluminum-clad Wood D06.5.4. Other
D07. Roof Systems
D07.1. Roof Type and Form
D07.2. Roof Slope
D07.3. Parapets and Copings
D07.4. Color and Reflectivity
D07.5. Gutters, Downspouts, Scuppers, Drains
D07.6. Roof Vents and Elements
D07.7. Clerestories and Skylights
D07.8. Vegetated Roof
Table of contents continued on next page
Table of contents continued
D07.9. Roof Systems Materials D07.9.1. Standing Seam Metal D07.9.2. Membrane Single-ply D07.9.3. Built-up Multi-ply D07.9.4. Concrete Tile D07.9.5. Clay Tile D07.9.6. Slate Shingles D07.9.7. Vegetated System D07.9.8. Ribbed Metal Sheeting D07.9.9. Composite Shingles D07.9.10. Other
D08. Structural Systems
D08.1. Systems and Layouts
D08.2. Structural Systems Materials D08.2.1. Concrete D08.2.2. Insulated Concrete Forming (ICF) D08.2.3. Steel D08.2.4. Pre-Engineered Steel D08.2.5. Masonry D08.2.6. Heavy Timber D08.2.7. Light-gauge Steel D08.2.8. Lumber Framing D08.2.9. Other
D09. Mechanical, Electrical and Plumbing
D09.1. Passive and Active Systems
D09.2. Functionality and Efficiency
E. FACILITIES INTERIORS
E01. Building Configurations
E01.1. Layout and Common Areas
E01.1.1. Interior Design Process E01.1.2. Codes and Regulations
E01.2. Quality and Comfort
E02. Floors
E02.1. Floor Materials
E02.1.1. Prepared Slabs E02.1.2. Natural Stone and Terrazzo E02.1.3. Quarry Tile E02.1.4. Ceramic Tile E02.1.5. Resilient Floor E02.1.6. Carpet E02.1.7. Rapidly-Renewable Products E02.1.8. Other
E03. Walls
E03.1. Wall Materials E03.1.1. Concrete E03.1.2. Masonry E03.1.3. Ceramic Tile E03.1.4. Gypsum Board E03.1.5. Metal Panels E03.1.6. Wood Paneling E03.1.7. Rapidly-Renewable Products E03.1.8. Other
E04. Ceilings
E04.1. Ceiling Materials
E04.1.1. Exposed Framing (Roof / Floor Structure Above) E04.1.2. Exposed Concrete E04.1.3. Grid and Acoustical Tile E04.1.4. Gypsum Board E04.1.5. Metal Panels E04.1.6. Wood E04.1.7. Rapidly-Renewable Products E04.1.8. Other
E05. Doors and Windows
E05.1. Doors and Windows and Frames Materials E05.1.1. Aluminum E05.1.2. Hollow Metal E05.1.3. Wood E05.1.4. Other
E06. Casework Systems
E06.1. Casework Materials E06.1.1. Plastic Laminate E06.1.2. Solid Polymer Surface E06.1.3. Rapidly-Renewable Products E06.1.4. Metal E06.1.5 Other
E06.2. Countertop Materials
E06.2.1. Plastic Laminate E06.2.2. Solid Polymer Surface E06.2.3. Natural Stone E06.2.4. Cast Stone E06.2.5. Metal E06.2.6 Other
E07. Furnishings
E07.1. Durability and Serviceability
E07.2. Accessories
E08. Interior Signs
E08.1 Types and Color
E08.2. Interior Signs Materials
E09. Lighting, Power and Communication
E09.1. Functionality and Efficiency
E09.2. Types and Color
F. Appendices
G. Appendices
Version 02.00.10
Page 5 of 148JBER Elmendorf IFS Back to Table of Contents
A. OVERVIEW
Comply with Air Force Corporate Standards for Overview:
http://afcfs.wbdg.org/index.html
This Installation Facilities Standards (IFS) document is part of the Air Force Corporate Facilities Standards (AFCFS) program to assist bases in implementing and maintaining facilities standards as appropriate for efficient operations within the respective climate region. IFS fully replaces, consolidates and simplifies existing facilities standards documents, such as the Architectural Compatibility Plan (ACP) or ACGs, FEPs, etc., and organizes information using the same structure, or Table of Contents, as the AFCFS website.
IFS reflects the AFCFS’ concepts of "Facility Hierarchy" (categorizing facilities into group numbers) and “Facility Quality” (assigning an appropriate level of quality to each group number) and applies these principles at the base level. Applicable DoD and Air Force criteria such as UFCs, AFIs, Memoranda, and UFGSs (Guide Specs) are referenced and linked within IFS to ensure the document is always current.
Navigating within this IFS is efficient and straightforward. Please use the interactive Table of Contents to locate subject matter, and click on the title of a section to access it. From any page, click on the “Back to Table of Contents” footer to return. Content is organized into 4 major sections: Installation Elements, Site Development, Facilities Exteriors and Facilities Interiors.
This IFS document begins as a fill-in PDF form, which is fully editable, and becomes a "living document" that can be regularly updated by base-level personnel following a format that is consistent across the Air Force. While the format is standardized, IFS content is customized for base operations and the local climate to ensure mission success while emphasizing reduced maintenance and reduced initial costs, life-cycle costs, energy use, and water use.
1. Conformance to Air Force Corporate Facilities Standards (AFCFS) and Installation Facilities Standards (IFS) are required by Air Force Instruction (AFI) 32-1023 and Air Force Memorandum. Please refer to the AFCFS website for links to documentation on current policy.
2. Requests to deviate from any installation facilities standards, that are Unified Facilities Criteria (UFC) requirements, will follow the process outlined in the AFCFS for UFC waivers and exemptions.
3. The IFS is a component plan of the Installation Development Plan (IDP) per Air Force Instruction (AFI) 32-7062 (replacing the Architectural Compatibility Plan). All military construction projects and Non-Appropriated Funds (NAF) facilities are required to comply with the IDP and its IFS component plan by AFI 32-1023. The Base Civil Engineer (BCE) maintains and implements the IDP and its component plans, to include the IFS.
4. Please refer to the AFCFS website as a portal to reference materials and requirements documents for design and construction projects (via links). Specific references to current DoD memoranda and Air Force criteria are updated periodically to provide the most current guidance and requirements. Programming, design and contract documents should list “current edition” for all reference and requirements documents. The documents in force at the date of execution of the design and/or construction contract shall be the governing version.
5. Advanced Modeling Requirements:
For all Air Force projects requiring advanced modeling, to include 3D visualization, Building Information Modeling (BIM), facility data, quantity take-off, geospatial, etc., follow the Army standards. Refer to USACE Minimum Model Matrix (M3) and Project Execution Plan (PxP) which outline required model uses. Refer to CAD BIM Technology Center (Contract Requirements) for more information on M3 and PxP.
6. Joint Bases shall implement IFS under their Joint-Base designation with volume numbers for individual installations following the IFS Development Tool template. For example, for Joint Base Langley-Eustis, provide: Vol. 1 Langley AFB and Vol. 2 Fort Eustis.
7. References and Supplementary Documents listed in Appendix G are included in these Installation Facilities Standards by reference and are fully part of this document. Please refer to Appendix G for a listing of documents, which are available via hyperlink for viewing and downloading.
Page 6 of 148JBER Elmendorf IFS Back to Table of Contents
Large graphicsApplicable N/A Select number of graphics / images (large: 800 px x 440 px) to insert 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
OPTIONAL: Insert Overview graphic that represents the region, locale or base
800 pixels width x 440 pixels in height
(jpg or png format)
Denali, Named Officially in 2015, Was Previously Named Mount McKinley in 1917 to Commemorate US President William McKinley
OPTIONAL: Insert Overview graphic that represents
250 pixels width x 188 pixels height
Flightline with Mountain Backdrop
OPTIONAL: Insert Overview
Recreational Area in Mountain Setting
OPTIONAL: Insert Overview
Common Wildlife Sighting
A01. FACILITY HIERARCHY
Comply with AF Corporate Standards for Facility Hierarchy (and subsections):
http://afcfs.wbdg.org/facility-hierarchy/index.html
A02. FACILITY QUALITY
Comply with AF Corporate Standards for Facility Quality (and subsections):
http://afcfs.wbdg.org/facility-quality/index.html
A03. FACILITY DISTRICTS
Comply with AF Corporate Standards for Facility Districts (and subsections):
http://afcfs.wbdg.org/facility-districts/index.html
Page 7 of 148JBER Elmendorf IFS Back to Table of Contents
Note: Apply the base-wide standards in this IFS for Installation Elements, Site Development, Facilities Exteriors and Facilities Interiors (products, materials, color, etc.). Following application of the base-wide standards, refer to the Appendix and apply any additional requirements specifically related to the Facility District.
Insert Base Map with districts indicated.
800 pixels width x 800 pixels height
Overview Map:JBER Elmendorf IFS
Image Tool 800 x 800
Page 8 of 148JBER Elmendorf IFS Back to Table of Contents
B. INSTALLATION ELEMENTS
Comply with Air Force Corporate Standards for Installation Elements:
http://afcfs.wbdg.org/installation-elements/index.html
B01. COMPREHENSIVE PLANNING
Comply with Air Force Corporate Standards for Comprehensive Planning:
http://afcfs.wbdg.org/installation-elements/comprehensive-planning/index.html
B01.1. Installation Development Plan (IDP)
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Small graphics do not applySmall graphics
Insert IDP graphic
Department of Defense, Department of the Air Force and Air Force Base Criteria
1. The Base Civil Engineer is responsible for developing, maintaining and implementing the installation’s Comprehensive Planning documents and to ensure that the Installation Development Plan (IDP) is prepared, maintained, and implemented following AFI 32-7062.
Page 9 of 148JBER Elmendorf IFS Back to Table of Contents
B01.1.1. IFS Component Plan of IDP
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert IFS Component Plan graphic
Aerial View of JBER Elmendorf
Kodiak Hall Site Plan
Kodiak Hall Concept Sketch
Climatic Considerations Diagram
1. Maintain this Installation Facilities Standards (IFS) as a Component Plan of the base’s Installation Development Plan (IDP).
Page 10 of 148JBER Elmendorf IFS Back to Table of Contents
B01.1.2. Brief History of Base
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert History of Base graphic
11 AF ALCOM Facility
Joint Mobility Complex
Joint Military Mall
Construction on Elmendorf Field began on 8 June 1940, as a major and permanent military airfield near Anchorage. The first Air Corps personnel arrived on 12 August 1940.
On 12 November 1940, the War Department formally designated what had been popularly referred to as Elmendorf Field as Fort Richardson. The air facilities on the post were named Elmendorf Field in honor of Captain Hugh M. Elmendorf, killed in 1933 while flight-testing an experimental fighter near Wright Field, Ohio. After World War II, the Army moved its field-operations units to the new Fort Richardson and the Alaska Air Force was established at Elmendorf Field at the original Fort Richardson.
Many flying units have been assigned to Alaska including the 18th Pursuit Squadron and 23rd Air Base Group in 1941, and the Eleventh Air Force, which was formed in early 1942. Following World War II, Elmendorf evolved in its flying missions to support both wartime and peacetime and operations. The strategic importance of Elmendorf AFB was continually reinforced with ongoing operations and systems and was ultimately added to the Pacific Command to serve the Pacific region. Other assigned flying units include the 43d Tactical Fighter Squadron, 18th Tactical Fighter Squadron, 90th Tactical Fighter, 2lst Tactical Fighter Wing, 54th Tactical Fighter Squadron, and 3rd Wing.
The 2005 Air Force and Army operations were realigned into a new configuration and established as Joint Base Elmendorf- Richardson (JBER). The decision listed the Air Force as the supporting agency, implementing and providing the funding vehicle for support to the entire joint base.
JBER comprises 5,500 joint military and civilian personnel, supporting America's Arctic Warriors and their families. The joint base supports and enables three Air Force total-force wings, two Army brigades and 75 associate and tenant units.
For an expanded history, please refer to the Joint Base Elmendorf-Richardson website.
Page 11 of 148JBER Elmendorf IFS Back to Table of Contents
B01.1.3. Future Development
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Insert Future Development graphic
JBER-E District in the Foreground with the Airfield Beyond
1. Follow AFI 32-7062 for Air Force Comprehensive Planning, the Comprehensive Planning Process, Comprehensive Planning Requirements, and Geospatial Mapping.
2. Address all future development under the Installation Development Plan (IDP).
Page 12 of 148JBER Elmendorf IFS Back to Table of Contents
B02. STREET ENVELOPE STANDARDS
Comply with Air Force Corporate Standards for Installation Elements:
http://afcfs.wbdg.org/installation-elements/index.html
Comply with AF Corporate Standards for Street Envelope Standards:
http://afcfs.wbdg.org/installation-elements/street-envelope-standards/index.html
B02.1. Hierarchy of Streets
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 2 Image Tool 250 x 188
Insert Hierarchy of Streets graphic
Richardson Drive Looking East
Hierarchy of Streets
Street Envelope Section
1. Develop and evolve a hierarchical transportation network of arterial, collector and local streets following UFC 3-201-01 and its industry references.
Page 13 of 148JBER Elmendorf IFS Back to Table of Contents
2. Provide consistent functionality throughout the installation and a level of visual quality relating to the adjacent Facility Group number.
3. Routes along facilities in Group 1 may have materials, finishes and features with a higher visual quality than Groups 2, 3 and 4.
Reduce maintenance requirements by installing highly durable materials and finishes in routes along Group 3 industrial facilities.
Consider snow removal operations and snow storage areas in all designs.
4. Special routes may have a visual quality comparable to those along facilities in Group 1.
5. Create and maintain arterials with two lanes of traffic in each direction with landscaped or paved medians as applicable to the local climate and adjacent facility group designation / land use.
6. Minimize stops and turns along arterials. Eliminate on-street parking along arterials and collector streets.
7. Connect arterials to local streets with appropriately scaled collector streets.
8. Provide appropriate landscape setbacks and pedestrian buffers along all streets.
9. Minimize and consolidate curb cuts along streets.
10. Ensure access for emergency and service vehicles.
11. Define bicycle traffic routes in the Installation Development Plan or its applicable component plans.
12. Remote service roads may be paved with a rock/clay mix that is suitable for the service vehicles. Appropriately size roads to accommodate service vehicle traffic.
Page 14 of 148JBER Elmendorf IFS Back to Table of Contents
B02.1.1. Arterial Streets
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Arterial Streets graphic
Travel Lane (a): 12’ Median (b): 12’ Curb and Gutter (c): 2’ Sidewalk / Landscape (d): 12’) Setback (f): Min. 35' or per ATFP
Divided Arterial at Gate
Center Turning Lane
Striped Median
1. Minimum arterial street dimensions shall be as follows:
a. Travel Lane. 12’
b. Median (if used). 12’
c. Curb and Gutter. 2’
d. Sidewalk. 6’
e. Parking. 12’ setback or per ATFP
f. Buildings. 35’ setback or per ATFP
g. Obstructions. 6’ setback or per ATFP
Page 15 of 148JBER Elmendorf IFS Back to Table of Contents
2. Stops and turns should be minimized and on-street parking shall not be allowed at any point along arterial streets.
3. Provide sidewalks on at least one side of arterial streets and both sides of arterial streets in developed areas. Provide a 6 foot buffer between the road and sidewalk where space allows.
4. Limit curb cuts on arterial streets to entries into major facilities, building groups and major parking areas.
5. Signs, plantings and street lighting should be added to reinforce the importance of arterial streets.
B02.1.2. Collector Streets
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 2 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Collector Streets graphic
Travel Lane (a): 12’ Median (b): Optional Curb and Gutter (c): 2’ Landscape (d): 10’ Sidewalk (e): 6’ Setback (f): Min. 35' or per ATFP
Page 16 of 148JBER Elmendorf IFS Back to Table of Contents
Collector Street Access to Group 1 Facilities
Slammer Avenue
Typical Collector Streetscape
Concentrated Landscaping at Dorm Area
1. Minimum collector street dimensions shall be as follows:
a. Travel Lane. 12’
b. Median (if used). 12’
c. Curb and Gutter. 2’
d. Sidewalk. 6’
e. Parking. 12’ setback or per ATFP
f. Buildings. 35’ setback or per ATFP
g. Obstructions. 3’ setback or per ATFP
2. Frequent traffic stops and low speeds are permitted on collector streets.
3. Provide sidewalks on at least one side of collector streets. Buffers are preferred but not required on collector streets.
4. On street parking may be allowed on one side where secondary roads are over 28 feet wide but not less than 34 feet wide.
Parking shall not interfere with intersections or traffic flow.
Page 17 of 148JBER Elmendorf IFS Back to Table of Contents
5. Signs, plantings and street lighting should be added to reinforce the importance of arterial streets.
B02.1.3. Local Streets
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Local Streets graphic
Travel Lane (a): 11’ Median (b): Optional Curb and Gutter (c): 1.5’ Landscape (d): 15’ Sidewalk (e): 6’
Attached Sidewalk
Coordinated Street Elements
Group 4 Local Street
1. Minimum local street dimensions shall be as follows:
a. Travel Lane. 11’
b. Curb and Gutter. 1.5’
c. Sidewalk. 6’
d. Landscape. 15’ setback or per ATFP
e. Buildings. 35’ setback or per ATFP
f. Obstructions. 3’ setback or per ATFP
Page 18 of 148JBER Elmendorf IFS Back to Table of Contents
2. Frequent traffic stops and low speeds are permitted on local streets.
3. Provide sidewalks on at least one side of local streets. Buffers are preferred but not required on local streets.
4. On street parking may be allowed on one side where secondary roads are over 28 feet wide but not less than 34 feet wide.
Parking shall not interfere with intersections or traffic flow.
5. Signs, plantings and street lighting should be added to reinforce the importance of arterial streets.
6. Cul-de-sacs are to only be used in the Family Housing areas. The minimum radius for cul-de-sacs shall be 50’.
B02.1.4. Special Routes
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 2 Image Tool 250 x 188
Insert Special Routes graphic
Open Space along Roadway
Insert Special Routes graphic
Controlled Access to Inspection Facility
1. Develop all special routes consistently with those adjacent to Group 1 facilities.
2. Special routes shall include the following streets:
a. Vandenberg Avenue from the Boniface Gate to Richardson Drive
b. Richardson Drive from Vandenberg Avenue to JBER Richardson
c. Arctic Warrior Drive from Vandenberg Avenue to the Government Hill Gate
3. Maintain the allee of trees, grasses, landscape beds, trails and setback area along Richardson Drive.
Page 19 of 148JBER Elmendorf IFS Back to Table of Contents
B02.2. Hierarchy of Intersections
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Insert Hierarchy of Intersections graphic
Intersection of Vandenberg Avenue and Richardson Drive looking East
1. Provide a hierarchy of intersections to include arterial, arterial-collector, collector, collector-local and local following UFC 3-201-01 and its industry references.
2. Passive systems such as traffic circles are preferred to active systems such as signalized intersections. Aggressively pursue passive systems to lower maintenance requirements and reduce energy use.
3. Use a level of visual quality for an intersection equal to the quality found in the related streetscape, which corresponds to the adjacent Facility Group number.
Page 20 of 148JBER Elmendorf IFS Back to Table of Contents
B02.2.1. Arterials
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 2 Image Tool 250 x 188
Insert Arterials graphic
Arctic Warrior Drive Traffic Signal
Insert Arterials graphic
Non-Signalized Intersection
1. At intersections adjacent to Group 1, landscaping of native grasses and shrubs may be provided; trees may be included when maintenance and non-potable irrigation is available. Monuments and static displays may be integrated into arterial intersection designs.
B02.2.2. Arterial/Collector
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Arterial/Collector graphic
Coordinated Systems
Merge Lanes at "T" Intersection
Triangular Median
1. At arterial/collector intersections adjacent to Group 1, landscaping of native grasses and shrubs may be provided; trees may be included when maintenance and non-potable irrigation is available.
Page 21 of 148JBER Elmendorf IFS Back to Table of Contents
B02.2.3. Collectors
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 2 Image Tool 250 x 188
Insert Collectors graphic
Coordinated Striping and Markings
Insert Collectors graphic
Typical Intersection Signs
1. At collector intersections adjacent to Group 1, landscaping of native grasses and shrubs may be provided; trees may be included when maintenance and non-potable irrigation is available. Intersections adjacent to Group 2 may be developed similarly, but with less detailing.
Page 22 of 148JBER Elmendorf IFS Back to Table of Contents
B02.2.4. Special Intersections
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Insert Special Intersections graphic
Signalized intersection at Vandenberg Avenue and Arctic Warrior Drive
1. Develop all special intersections consistently with those adjacent to Group 1 facilities.
Page 23 of 148JBER Elmendorf IFS Back to Table of Contents
B02.2.5. Street Frontage Requirements
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Street Frontage Requirements graphic
Integrated Landscape
Coordinated Building Identification Sign
Landscape Screening
1. Consistently maintain open space buffers following B03.2.3. Preserves.
2. Refer to C06.1.7. Streetscape Landscaping for planting and screen wall requirements along street frontage.
B02.2.6. Sight Lines
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Sight Lines graphic
Preserved Sight Lines
Coordinated Sign Placement
Merge Lane Configuration
1. Provide adequate sight lines for an effective and safe traffic operation per American Association of State Highway and Transportation Officials (AASHTO) standards and local municipality guidelines.
Page 24 of 148JBER Elmendorf IFS Back to Table of Contents
B02.3. Street Elements
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Street Elements graphic
Concrete Median
Rock Paving at Shoulder
Base Standard Crosswalk Striping
1. Emulate the streetscape area’s pre-development hydrology using passive and active design features to help sustain the adjacent regionally appropriate landscape. Coordinate with the base Stormwater Management Plan.
2. Employ systems, materials and techniques to maximize streetscape sustainability. Consider pervious paving and low reflectivity of surfaces, which is appropriate for the local climate.
3. Install at-grade curbing and/or raised-profile curb and gutter as applicable to direct stormwater to bioswales and rain gardens as source water for vegetation. Do not paint concrete curbing.
4. Provide all on-site utility service lines and equipment below grade when adjacent to Facility Group 1. In routes along Group 2, 3 and 4, when mounting elements such as utility cabinets, communications equipment and water valves above grade is unavoidable, paint these consistently and provide visual screening following Installation Facilities Standards (IFS).
5. Provide traffic control devices including access control point/entry control facility signs, speed limit signs and street name signs following the current edition of the Manual on Uniform Traffic Control Devices (MUTCD) per UFC 3-120-01.
6. Crosswalk markings shall follow the MUTCD for Streets and Highways, current edition. Provide white markings that define the edges of the crosswalk or a tone of lines defining the area of the crosswalk consistent with common practices found in the adjacent municipality.
7. Follow UFC 3-120-01 for directional and wayfinding signs and address both vehicular and pedestrian traffic.
8. Reduce energy consumption and reduce maintenance requirements by providing street lighting only when functionally required to ensure safety and to address antiterrorism following UFC 4-010-01. Ensure the quality and quantities of lighting and fixtures are appropriate for the adjacent Facility Group number.
Page 25 of 148JBER Elmendorf IFS Back to Table of Contents
B02.3.1. Paving
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Paving graphic
Typical Bituminous Paving
Integrated Curb and Gutter
Coordinated Street Markings
1. Pavement design shall comply with UFC 3-250-01. Ensure appropriate analysis and design of subgrade conditions to promote low maintenance, high performance pavements. Apply all applicable best practices from Appendix B of the UFC.
2. Materials shall be specified in accordance with UFC 3-250-01 and must conform to requirements set forth in the Unified Facility Guide Specifications (UFGS) for concrete and bituminous pavement.
B02.3.2. Curb and Gutter
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Curb and Gutter graphic
Group 1, 2 and 3 Section
Group 4 Section
Barrier Curb with Attached Sidewalk
1. Curb all streets except remote/isolated roads and rock-paved service roads. Header curbs may be used to facilitate snow plowing operations when coordinated with the base stormwater plan.
2. All streets should have integral concrete curbs and gutters. Painted curbs are prohibited because they are very difficult to maintain.
3. Use concrete for sidewalks and curbs. Do no use asphalt curbs.
Page 26 of 148JBER Elmendorf IFS Back to Table of Contents
B02.3.3. Utility Service Elements
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Utility Service Elements graphic
Coordinated Inlet and Manhole Cover
Fire Hydrant and Electrical Cabinet
Storm Inlet with Access Cover
1. Provide all utility service lines below grade when streets are adjacent to Facility Group 1; when mounting elements (such as utility cabinets, communications equipment and water valves) above grade is unavoidable, paint these consistently and provide visual screening following Site Development, Landscaping.
2. Overhead service lines along streets adjacent to Facility Groups 2, 3 and 4 are discouraged.
B02.3.4. Traffic Signs
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 1 Image Tool 250 x 188
Insert Traffic Signs graphic
Standard Traffic Signs
1. Refer to Exterior Signs, Colors and Types for Traffic Control Devices, which includes signs.
Page 27 of 148JBER Elmendorf IFS Back to Table of Contents
B02.3.5. Street Lighting
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 1 Image Tool 250 x 188
Insert Street Lighting graphic
Base Standard Street Lighting
1. Refer to the Lighting section for appropriate applications along streets.
B02.3.6. Other
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert graphic
Integrated ATFP Systems
Coordinated Bus Shelters
Base Standard Crosswalk Striping
Page 28 of 148JBER Elmendorf IFS Back to Table of Contents
B03. OPEN SPACE / PUBLIC SPACE
Comply with Air Force Corporate Standards for Installation Elements:
http://afcfs.wbdg.org/installation-elements/index.html
Comply with AF Corporate Standards for Open Space / Public Space:
http://afcfs.wbdg.org/installation-elements/open-space-public-space/index.html
B03.1. Plazas, Monuments and Static Displays
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Insert Plazas, Monuments and Static Displays graphic
Group 1 Plaza with Colored Concrete Accents
1. Natural features and culturally or historically significant features or events may be recognized and acknowledged with physical elements such as plazas, monuments and static displays. However, limit these elements on the base to ensure judicious use of resources and to reduce ongoing maintenance requirements.
2. Design highly durable plazas, monuments and static displays with a level of quality comparable to Facility Group 1.
3. Link plazas, monuments and static displays to the pedestrian circulation system. Install landscaping, site furnishings and lighting appropriate for the application and local climate following Installation Facilities Standards (IFS).
4. Select systems, products and materials for paving, walls, and structures following IFS.
Page 29 of 148JBER Elmendorf IFS Back to Table of Contents
B03.1.1. Paved Plazas
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Paved Plazas graphic
Memorial Plaza
Plaza with Contrasting Paving
Group 1 Plaza at Entrance
1. Pervious pavers may be used on all plazas and courtyards in Facility Groups 1 and 2; pervious concrete may be used in Groups 3 and 4. The designer shall incorporate appropriate expansion and construction joints.
2. Pavers shall match the color of pavers used on adjacent sidewalks using base standard range of beige or tan. Bricks used on plazas shall typically be 4” x 8” size. Avoid the use of pavers that effloresce or corrode when exposed to snow-melt chemicals.
B03.1.2. Sculptures, Markers and Statuary
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Sculptures, Markers and Statuary graphic
Post-Mounted Plaque
Wall-Mounted Plaques and Symbols
Photographic Interpretive Marker
1. Relate new sculpture, markers and statuary to the base’s architectural design theme. Generally limit these elements to frequently used locations adjacent to Facility Group 1 and highly traveled community pedestrian spaces.
2. Consider entry gates as possible sites for new displays.
3. All proposed memorials shall follow AFI 36-3108 and be limited to highly deserving individuals or groups as deemed appropriate by the installation leadership. Living memorials (tree plantings / etc.) are discouraged due to added maintenance requirements.
4. When sculpture requires a base, match the materials and / or color palette of adjacent buildings.
Page 30 of 148JBER Elmendorf IFS Back to Table of Contents
5. Use direct or indirect lighting to accentuate features or enhance an intended effect.
6. Ensure that all sculpture, markers and statuary are honorable and inspiring, provide a sense of place, positively contribute to the base’s visual quality, and encourage pride for the community and the US Air Force.
B03.1.3. Static Display of Aircraft
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Static Display of Aircraft graphic
Aircraft Display Park with Flag Array and Platform
Insert Static Display of Aircraft
Typical Ground-Mounted Display
Low Wall for Plaques and Symbols
Uplighting Fixtures at Displays
1. Follow IFS base-wide standards for all elements of the display area with specific attention to traffic sight lines, pedestrian circulation, site furnishings, signs, and lighting. Address requirements for the Facility District as well.
2. Generally locate concrete base/foundation structures for static displays below grade.
Page 31 of 148JBER Elmendorf IFS Back to Table of Contents
3. At static displays where pedestrian paths are provided, a minimum of one trash receptacle and one bench shall be provided.
Receptacle and bench design must conform to IFS requirements.
B03.2. Grounds and Perimeters
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Grounds and Perimeters graphic
Open Space Buffer between Differing Land Uses
Insert Grounds and Perimeters
Recreational Area
Integrated Berm and Swale
Open Space Buffer along Roadway
1. Provide formal spaces for parade and review functions, recreational areas and parks following the base’s Installation Development Plan (IDP) and Installation Facilities Standards (IFS). Refer to the Site Furnishings topic for additional information.
2. Maintain preservation areas following the IDP and IFS.
Page 32 of 148JBER Elmendorf IFS Back to Table of Contents
3. Comply with UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings and UFC 4-022-03 Security Fences and Gates for all elements associated with the base’s gates and perimeter fence.
4. Identify and describe base-wide utility corridors in the IDP.
5. Base-wide utility infrastructure shall be inconspicuous. Bury utility service lines below grade when adjacent to Facility Group 1 and when economically feasible for Facility Groups 2, 3 and 4. When service lines are located above grade, create an ordered, coordinated appearance.
6. Follow the requirements of this IFS regarding all utility structures and service lines located above grade that visually impact the installation.
7. Where screening of utility equipment and structures is provided, allow adequate and proper clearance for safety and maintenance.
8. Reduce visual clutter and visual impact of the following items through a combination of careful placement, screen walls, landscaping and painting:
• Electrical switch-stations
• Sewage lift stations
• Water well pumps, storage tanks and/or related structures
• Gas piping, meters and similar incidental items
• Above ground fuel storage tanks
• Any ground-mounted freestanding utility item exposed to view
9. Larger structures such as electrical switch-stations, sewage lift stations, fuel storage tanks and mechanical/electrical equipment shall be screened from view, using materials, forms, and colors in the screen walls which match those respective design elements present at adjacent buildings.
10. Paint above-ground equipment and associated components such as electrical piping or exposed plumbing lines dark bronze.
11. Maintain currently buried utility service lines as a visual asset.
12. Bury the following exposed above-grade items in future projects when economically feasible:
• Electrical power grid and service lines
• Telephone lines
• Cable TV lines
• Communications lines
• Exterior lighting service lines
• Any similar system of above-ground lines serving the base
13. Consolidate and enclose service utility lines in underground utility corridors when feasible. Create routes along the inside edge of parking lot islands.
B03.2.1. Parade Grounds
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Small graphics do not applySmall graphics
1. Preserve areas adjacent to runways, taxiways, aprons, golf course roughs, storage areas, antenna facilities, and ammunition storage areas, as open space.
2. Provide minimal maintenance with mowing as needed for controlling bird behavior for airfield safety, or eliminating fire hazards.
Page 33 of 148JBER Elmendorf IFS Back to Table of Contents
B03.2.2. Parks
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Parks graphic
Otter Lake Recreation Area
Park Pavilion
Play Equipment at Park
Picnic Pavilion
1. Bleachers may be installed only when there is a documented requirement at parks and fields for recreational events. Follow guidance under Parade Grounds.
2. Picnic pavilions may be provided in parks where there is a documented need.
3. Prohibited picnic pavilion materials include wood, concrete masonry units (CMU) or metal pre-manufactured storage sheds.
Use only materials and detailing that is low maintenance and endures with minimal weathering.
Page 34 of 148JBER Elmendorf IFS Back to Table of Contents
4. When picnic pavilions are permitted near facilities, generally match the architecture of the adjacent facility and provide a level of quality of the adjacent facility group number.
B03.2.3. Preserves
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 3 Image Tool 250 x 188
Insert Preserves graphic
Preserved Open Space
Preserve as a Recreational Amenity
Wooded Basin with Bridge
1. Preserve areas adjacent to runways, taxiways, aprons, golf course roughs, storage areas, antenna facilities, and ammunition storage areas, as open space.
2. Provide minimal maintenance with mowing as needed for controlling bird behavior for airfield safety, or eliminating fire hazards.
B03.2.4. Perimeter Fence
Applicable N/A Large graphics do not applyLarge graphics
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 6 Image Tool 250 x 188
Insert Perimeter Fence graphic
Group 1 Metal Fencing
High Security Gate
High Security Chain Link
Page 35 of 148JBER Elmendorf IFS Back to Table of Contents
Coordinated Berm and Landscape
Adjacent Wooded Area
Standard Signs
1. Design, install and maintain the base’s perimeter fence following UFC 4-022-03.
2. Stringently comply with ATFP requirements following UFC 04-010-01 for all spaces adjacent to the base’s perimeter fence and all gates.
3. Fencing, gates and other elements that are associated with the main gates shall be a level of quality equivalent to Facility Group 1.
4. Maintain a positive visual quality along the traffic corridor on both sides of the main gates. Specifically address pedestrian access, circulation and common areas.
Page 36 of 148JBER Elmendorf IFS Back to Table of Contents
C. SITE DEVELOPMENT
Comply with Air Force Corporate Standards for Site Development:
http://afcfs.wbdg.org/site-development/index.html
C01. SITE DESIGN
Comply with Air Force Corporate Standards for Site Development:
http://afcfs.wbdg.org/site-development/index.html
Comply with AF Corporate Standards for Site Design / NEPA:
http://afcfs.wbdg.org/site-development/site-design-nepa/index.html
C01.1. Site Design Considerations
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Insert Site Design Considerations graphic
Fitness Center and Adjacent Grounds
1. Collect documentation to validate approvals and completion of the NEPA process.
2. Ensure site design compliance with the Installation Development Plan (IDP) and its component plans and Installation Facilities Standards (IFS).
3. Promote integrated design with on-site solutions such as engineered small-scale hydrologic controls verses base-wide infrastructure; consider open space, natural features, bioswales, building roofs, streets, paved surfaces, and snow storage areas.
4. Integrate snow storage areas with adjacent streets and parking areas; coordinate snow storage with the base stormwater plan.
5. Limit the impact of development on land and water resources. All site elements and infrastructure shall reinforce an image of sustainability, with reduced energy demand, renewable-energy usage, and water conservation.
Page 37 of 148JBER Elmendorf IFS Back to Table of Contents
6. Consider energy conservation during site design for the following categories: building and site lighting, auxiliary systems and equipment (refrigerators, elevators, etc.), building envelope, electric power and distribution, HVAC systems and equipment, service hot water, energy management (metering, EMCS).
7. Coordinate on-site renewable-energy systems and components to minimize area requirements and maximize efficiencies.
Appropriately buffer and screen these and other mechanical systems and equipment.
8. New building projects should preserve open space and protect natural habitat.
9. Conform to existing topography to the greatest extent possible and use slopes to increase site and building efficiencies. Design sites to minimize irrigation and impacts to stormwater runoff.
10. Carefully study new project sites to identify the character of adjacent buildings, streets, landscaping, and site design elements.
Reinforce the existing character in new site design.
11. Consider relationships to adjacent facilities and district / centralized heating and cooling infrastructure and cost effectively connect building systems to harvest heat, grey water or other beneficial byproducts.
12. Minimize existing and planned obstructions from landscaping, structures, topography, and adjacent developments to preserve solar access and natural ventilation.
13. Purposefully integrate service access, receiving and storage areas to eliminate the need for visual screening.
14. Appropriately connect to the base network of streets, sidewalks and trails using drive aisles, parking areas, walkways, paths, and bicycle routes addressing both vehicles and pedestrians.
15. Applicably coordinate roof designs and roof drainage when implementing an integrated approach to stormwater management.
16. Consider the location of “Designated Tobacco Areas.”
Page 38 of 148JBER Elmendorf IFS Back to Table of Contents
C01.2. Building Orientation
Applicable N/A Select number of graphics / images (large: 800 px x 440 px) to insertLarge graphics 1 Image Tool 800 x 440
Applicable N/A Select number of graphics / images (small: 250 px x 188 px) to insertSmall graphics 6 Image Tool 250 x 188
Insert Building Orientation graphic
Conceptual Site Analysis and Site Design Diagram
Local Solar Data
Local Climate Data
Site Data
Page 39 of 148JBER Elmendorf IFS Back to Table of Contents
East-West Axis
Optimum Solar Control
Optimized Solar Heat Gain
1. Ensure the site will accommodate optimum requirements for building orientation, which is with the long axis and main entrance facing south to southeast.
2. Meet Installation Facilities Standards (IFS) requirements for the locations of the building’s passive and renewable-energy systems—including geothermal and solar systems—and exterior shading systems.
3. Locate the building(s) and permitted ancillary structures to promote solar gain, solar shading, natural ventilation, rainwater harvesting, wind buffering and other beneficial passive systems.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .