This is a collection of technical specification sheets and submittals for HVAC equipment and components related to project FA4600-25-R-0002 for repair work in Building 1226 at Offutt Air Force Base. The documents include detailed specifications for multiple HVAC units including: console geothermal heat pumps ranging from 0.75 to 1.5 tons, SmartSource compact single-stage units from 1-6 tons, circulation pumps, expansion tanks, air eliminators, dirt separators, and a Knight XL commercial condensing boiler.

The specifications cover comprehensive technical data such as cooling/heating capacities, electrical requirements, physical dimensions, operating parameters, materials of construction, and standard features for each piece of equipment. Major components include Daikin Applied heat pumps, Bell & Gossett pumps and expansion tanks, Spirotherm air/dirt separators, and a Lochinvar boiler rated at 97% thermal efficiency. The submittal package provides detailed performance data, installation requirements, and dimensional drawings that would be needed for construction and installation of the HVAC system upgrades.

View the file

Other files for this federal contract opportunity

Other files attached to Offutt AFB Multiple Award Construction Contract (MACC), newest first.
File Type Posted
Sol Amendment FA460025R00020004.pdf PDF
Attachment 17_230700_THERMAL INSULATION FOR MECHANICAL SYSTEMS 2025-04-03.pdf PDF
MACC QnA_11Apr25_F.xlsx XLSX spreadsheet
Attachment 5_Offutt AFB MACC SOW_r1.pdf PDF
Amendment FA460025R00020003.pdf PDF
Sol Amendment 25R00020002.pdf PDF
MACC Site Visit_18March2025.pdf PDF
Amendment FA460025R00020001.pdf PDF
MACC Site Visit_06March2025.pdf PDF
Attachment 1_Division 0 - 00 10 00 Section 1A_Mar22.pdf PDF
Attachment 5_Offutt AFB MACC SOW.pdf PDF
Attachment 7_21-0048 Project Diagram.pdf PDF
Attachment 8_21-0048 Repair Water Line Design Analysis.pdf PDF
Attachment 12_SGBP 22-0041 Repair HVAC B1226 Drawings.pdf PDF
Attachment 15_SGBP 22-0041 Repair HVAC B1226_Design Analysis.pdf PDF
Attachment 16_WD_NE20250059.pdf PDF
MACC_55 SFS Contractor Vendor NCIC Screening Pass Request.pdf PDF
Solicitation - FA460025R0002.pdf PDF
Attachment 3_Division 1 - 01 33 01 AF66.pdf PDF
Attachment 4_Env Spec Conditions_Division 1_01 57 19_Nov24.pdf PDF
Attachment 10_21-0048 Repair Water Line Specifications.pdf PDF
Attachment 11_SOW_B1226 HVAC Renovation.pdf PDF
Attachment 13_SGBP 22-0041 Repair HVAC B1226 Specifications.pdf PDF
AF3052_Cost_Estimate_Breakdown.xlsx XLSX spreadsheet
Attachment 2_Division 1 - 01 33 00 Section 1B_Jan21.pdf PDF
Attachment 6_SOW_21-0048 Repair Water Line_F627.pdf PDF
Attachment 9_21-0048 Repair Water Line Drawings.pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Job Information Technical Data Sheet

Job Name Offutt B1226

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag CHP-0.75

Unit Overview

Model Number

Voltage V/Hz/Pha se

Air Flow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WMHW200

208- 230/60/1

345 2.40 9430 16.10 14.24 7365 3.20 3.73

Unit

Model Number: WMHW2009

Unit Type: Console Geothermal Range

Unit Construction: Standard Fiberglass Insulation

Approval: None

Refrigerant Type Refrigerant Weight

R-410A 21.0 oz

Unit Performance

Air & Water Flow

Airflow Fluid Flow Fluid Type Glycol Concentration Fluid Pressure Drop

345 CFM 2.40 gpm / 3.20 gpm/ton Propylene Glycol 30.0 % 3.91

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

designEntering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

85.0 95.1 80.0 67.0 61.7 58.1 9430 6709 11623 14.24

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption Btu/hr

COP @ design

Entering Leaving Entering Leaving Total Btu/hrDry Bulb Dry Bulb

40.0 35.2 70.0 89.8 7365 5465 3.73

Electrical

Unit Voltage Minimum Voltage Total Unit MCA Total Unit Full Load Current

208-230/60/1 187 V 4.9 A 4.0 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

3.60 A 21.0 A 0.4 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

CHP‐0.75 Technical Data Sheet

OM143U Offutt B1226 4 6/21/2024

FA460025R0002

Attachment 14

Physical

Unit

Length Height Width Weight Connections

Shipping Operating Water, OD Condensate, ID

46.0 in 25.0 in 10.8 in 164 lb 144 lb 0.625 in 0.75 in

Cabinet

Construction Type Cabinet Type

Standard Fiberglass Insulation Flat Top

Piping Hand Cabinet Height Discharge Grille

Left Hand High Sill - 25" Standard 1-piece Steel

Color

Cabinet Subbase Grille

Antique Ivory Oxford Brown Oxford Brown

Fan Controls

Type Motor Drive Type

Type Horsepower Type

Tangential Standard PSC 0.033 HP Direct Microtech III Unit

Controller - Standalone

(1) 29.25 in x 9.75 in x 0.5 in

Options

Heating

Heat Exchanger: Copper

Drain Pan Material

Primary: Plastic

Controls

Thermostat Mounting: Remote - Wall Mounted Thermostat

Thermostat Type: Programmable

Control Transformer: 50VA Control Transformer

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada.

CHP‐0.75 Technical Data Sheet

OM143U Offutt B1226 5 6/21/2024

FA460025R0002

Indoor Air Quality (IAQ) Non-Fibrous Insulation - Closed-cell type (Rubatex)

Controls MicroTech III Unit Controller - Standalone operation L ® Communication Module BACnet® Communication Module

Warranty Ext. 4-Yr. Parts (Compressor Only) Ext. 4-Yr. Parts (Refrigerant Circuit)

2-Way Motorized Valve Packages (Option)

Extended End Pocket (Option)

Multi-Directional Grilles (Option) degrees for added control of discharge air direction.

Console Water Source Heat Pump – Flat Top Unit, High Sill, Left Hand Models MHC/MHW – Unit Size 009

Options (Factory Installed)

Physical Data Unit Size 009 Fan Wheel - D x W (In.)

Fan Motor Horsepower 1/30

Coil Face Area (Sq. Ft.)

Coil Rows

Refrigerant Charge (Oz.)

Filter, (Qty.) Size (Nominal)

Water Connections (In.) 5/8 O.D.

Condensate Connections (In.) 3/4 I.D.

Weight, Operating (Lbs.) 144

Weight, Shipping (Lbs.) 164

Cabinets

Compressor

™ Fan – User selectable, multi-speed tangential fan system

LED Annunciator – LED status lights display fault conditions to the left or right end panel to the control enclosure.

Filter

Hinged Control Box

MicroTech® III Unit Controller – expansion module can be used to control electric heat and multiple fan speeds. A separate L ® or BACnet® communication module can be easily snapped onto the board to accommodate the building automation system of your choice.

Double-Sloped Drain Pan

Air Dampers (Field-installed Accessory)

Unit Flexibility

MHC-MHW-FT-HS-L-009

Specs

The Water Source Heat Pump product represented on this document will conform to the drawings and may be made to this document without the prior, express, written authorization of the manufacturer.

Group: WSHP Type:

Date:

CHP‐0.75 MHC‐W_009_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 6 6/21/2024

FA460025R0002

Flat Top Unit, High Sill, Left Hand Piping – Size 009 Left and right hand piping determined by facing the front of the unit.

Top View

Left End View Front View

Dimensions

Note: Dimensions are approximate

Unit Size A B C D E F G H J K L M

46 16 0.6 1/5

N P Q R S T V Y

4 10 13/5 5 4

Extended End Pocket (Option) – Dimensions

CHP‐0.75 MHC‐W_009_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 7 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-1.0

13600 Industrial Park Blvd. Minneapolis, MN 55441 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV012 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 8 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-1.5 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV019 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 9 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-1.5 low www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV019 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 10 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-2.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV024 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 11 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-2.0 low www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV024 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 12 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-3.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV036 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 13 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-3.5 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV042 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 14 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-4.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV048 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 15 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-4.0 low www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV048 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 16 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-5.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV060 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 17 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-6.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV070 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 18 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-8.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WLVW1096 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 19 6/21/2024

FA460025R0002

www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WLVW1096 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

CHP‐0.75 Smart Source Drawings

OM143U Offutt B1226 20 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag CHP-1.0

Unit Overview

Model Number

Voltage V/Hz/Pha se

Air Flow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WMHW201

208- 230/60/1

360 2.90 11165 15.30 13.56 9719 3.20 3.51

Unit

Model Number: WMHW2012

Unit Type: Console Geothermal Range

Unit Construction: Standard Fiberglass Insulation

Approval: None

Refrigerant Type Refrigerant Weight

R-410A 21.5 oz

Unit Performance

Air & Water Flow

Airflow Fluid Flow Fluid Type Glycol Concentration Fluid Pressure Drop

360 CFM 2.90 gpm / 2.90 gpm/ton Propylene Glycol 30.0 % 5.61

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

designEntering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

85.0 95.0 80.0 67.0 58.8 56.8 11165 8092 13891 13.56

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption Btu/hr

COP @ design

Entering Leaving Entering Leaving Total Btu/hrDry Bulb Dry Bulb

40.0 34.9 70.0 95.0 9719 7055 3.51

Electrical

Unit Voltage Minimum Voltage Total Unit MCA Total Unit Full Load Current

208-230/60/1 187 V 6.0 A 4.9 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

4.40 A 30.0 A 0.5 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

CHP‐1.0 Technical Data Sheet

OM143U Offutt B1226 21 6/21/2024

FA460025R0002

Length Height Width Weight Connections

Shipping Operating Water, OD Condensate, ID

46.0 in 25.0 in 10.8 in 166 lb 146 lb 0.625 in 0.75 in

Cabinet

Construction Type Cabinet Type

Standard Fiberglass Insulation Flat Top

Piping Hand Cabinet Height Discharge Grille

Left Hand High Sill - 25" Standard 1-piece Steel

Color

Cabinet Subbase Grille

Antique Ivory Oxford Brown Oxford Brown

Fan Controls

Type Motor Drive Type

Type Horsepower Type

Tangential Standard PSC 0.033 HP Direct Microtech III Unit

Controller - Standalone

(1) 29.25 in x 9.75 in x 0.5 in

Options

Heating

Heat Exchanger: Copper

Drain Pan Material

Primary: Plastic

Controls

Thermostat Mounting: Remote - Wall Mounted Thermostat

Thermostat Type: Programmable

Control Transformer: 50VA Control Transformer

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada.

CHP‐1.0 Technical Data Sheet

OM143U Offutt B1226 22 6/21/2024

FA460025R0002

Controls MicroTech III Unit Controller - Standalone operation L ® Communication Module BACnet® Communication Module

Warranty Ext. 4-Yr. Parts (Compressor Only) Ext. 4-Yr. Parts (Refrigerant Circuit)

2-Way Motorized Valve Packages (Option)

Extended End Pocket (Option)

Multi-Directional Grilles (Option) degrees for added control of discharge air direction.

Console Water Source Heat Pump – Flat Top Unit, High Sill, Left Hand Models MHC/MHW – Unit Size 012

Options (Factory Installed)

Physical Data Unit Size 012 Fan Wheel - D x W (In.)

Fan Motor Horsepower 1/30

Coil Face Area (Sq. Ft.)

Coil Rows 3 Refrigerant Charge (Oz.)

Filter, (Qty.) Size (Nominal)

Water Connections (In.) 5/8 O.D.

Condensate Connections (In.) 3/4 I.D.

Weight, Operating (Lbs.) 146

Weight, Shipping (Lbs.) 166

LED Annunciator – LED status lights display fault conditions to the left or right end panel to the control enclosure.

Filter

Hinged Control Box

MicroTech® III Unit Controller – expansion module can be used to control electric heat and multiple fan speeds. A separate L ® or BACnet® communication module can be easily snapped onto the board to accommodate the

MHC-MHW-FT-HS-L-012

Specs may be made to this document without the prior, express, written authorization of the manufacturer.

Group: WSHP Type:

Date:

CHP‐1.0 MHC‐W_012_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 23 6/21/2024

FA460025R0002

N P Q R S T V Y

4 10 13/5 5 4

Flat Top Unit, High Sill, Left Hand Piping – Size 012

Note: Dimensions are approximate

Unit Size A B C D E F G H J K L M

46 16 0.6 1/5

Extended End Pocket (Option) – Dimensions

CHP‐1.0 MHC‐W_012_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 24 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag CHP-1.25

Unit Overview

Model Number

Voltage V/Hz/Pha se

Air Flow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WMHW201

208- 230/60/1

525 3.70 13820 17.30 16.58 12062 3.40 3.60

Unit

Model Number: WMHW2015

Unit Type: Console Geothermal Range

Unit Construction: Standard Fiberglass Insulation

Approval: None

Refrigerant Type Refrigerant Weight

R-410A 30.0 oz

Unit Performance

Air & Water Flow

Airflow Fluid Flow Fluid Type Glycol Concentration Fluid Pressure Drop

525 CFM 3.70 gpm / 2.96 gpm/ton Propylene Glycol 30.0 % 3.03

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

designEntering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

85.0 94.3 80.0 67.0 64.5 58.4 13820 8625 16578 16.58

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption Btu/hr

COP @ design

Entering Leaving Entering Leaving Total Btu/hrDry Bulb Dry Bulb

40.0 35.0 70.0 91.3 12062 8836 3.60

Electrical

Unit Voltage Minimum Voltage Total Unit MCA Total Unit Full Load Current

208-230/60/1 187 V 6.7 A 5.5 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

5.00 A 30.0 A 0.5 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

CHP‐1.25 Technical Data Sheet

OM143U Offutt B1226 25 6/21/2024

FA460025R0002

Length Height Width Weight Connections

Shipping Operating Water, OD Condensate, ID

54.0 in 25.0 in 10.8 in 196 lb 166 lb 0.625 in 0.75 in

Cabinet

Construction Type Cabinet Type

Standard Fiberglass Insulation Flat Top

Piping Hand Cabinet Height Discharge Grille

Left Hand High Sill - 25" Standard 1-piece Steel

Color

Cabinet Subbase Grille

Antique Ivory Oxford Brown Oxford Brown

Fan Controls

Type Motor Drive Type

Type Horsepower Type

Tangential Standard PSC 0.056 HP Direct Microtech III Unit

Controller - Standalone

(1) 37.25 in x 9.75 in x 0.5 in

Options

Heating

Heat Exchanger: Copper

Drain Pan Material

Primary: Plastic

Controls

Thermostat Mounting: Remote - Wall Mounted Thermostat

Thermostat Type: Programmable

Control Transformer: 50VA Control Transformer

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada.

CHP‐1.25 Technical Data Sheet

OM143U Offutt B1226 26 6/21/2024

FA460025R0002

Controls MicroTech III Unit Controller - Standalone operation L ® Communication Module BACnet® Communication Module

Warranty Ext. 4-Yr. Parts (Compressor Only) Ext. 4-Yr. Parts (Refrigerant Circuit)

2-Way Motorized Valve Packages (Option)

Extended End Pocket (Option)

Multi-Directional Grilles (Option) degrees for added control of discharge air direction.

Console Water Source Heat Pump – Flat Top Unit, High Sill, Left Hand Models MHC/MHW – Unit Size 015

Options (Factory Installed)

Physical Data Unit Size 015 Fan Wheel - D x W (In.) 7/16

Fan Motor Horsepower 1/18

Coil Face Area (Sq. Ft.) 2.22 Coil Rows 2 Refrigerant Charge (Oz.) 29.9 Filter, (Qty.) Size (Nominal)

Water Connections (In.)

Condensate Connections (In.)

Weight, Operating (Lbs.) 166

Weight, Shipping (Lbs.) 196

LED Annunciator – LED status lights display fault conditions to the left or right end panel to the control enclosure.

Filter

Hinged Control Box

MicroTech® III Unit Controller – expansion module can be used to control electric heat and multiple fan speeds. A separate L ® or BACnet® communication module can be easily snapped onto the board to accommodate the

MHC-MHW-FT-HS-L-015

Specs may be made to this document without the prior, express, written authorization of the manufacturer.

Group: WSHP Type:

Date:

CHP‐1.25 MHC‐W_015_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 27 6/21/2024

FA460025R0002

Flat Top Unit, High Sill, Left Hand Piping – Size 015

Unit Size A B C D E F G H J K L M

015 20½ 12½ 7 0.6 1/

N P Q R S T V Y

4 10 1 / 7½ 4

Extended End Pocket (Option) – Dimensions

CHP‐1.25 MHC‐W_015_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 28 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag CHP-1.5

Unit Overview

Model Number

Voltage V/Hz/Pha se

Air Flow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WMHW201

208- 230/60/1

475 4.60 16332 15.30 16.13 14074 3.40 3.75

Unit

Model Number: WMHW2018

Unit Type: Console Geothermal Range

Unit Construction: Standard Fiberglass Insulation

Approval: None

Refrigerant Type Refrigerant Weight

R-410A 33.0 oz

Unit Performance

Air & Water Flow

Airflow Fluid Flow Fluid Type Glycol Concentration Fluid Pressure Drop

475 CFM 4.60 gpm / 3.07 gpm/ton Propylene Glycol 30.0 % 4.31

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

designEntering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

85.0 93.9 80.0 67.0 60.4 55.5 16332 9886 19684 16.13

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption Btu/hr

COP @ design

Entering Leaving Entering Leaving Total Btu/hrDry Bulb Dry Bulb

40.0 35.2 70.0 97.5 14074 10465 3.75

Electrical

Unit Voltage Minimum Voltage Total Unit MCA Total Unit Full Load Current

208-230/60/1 187 V 8.2 A 6.7 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

6.20 A 32.0 A 0.5 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

CHP‐1.5 Technical Data Sheet

OM143U Offutt B1226 29 6/21/2024

FA460025R0002

Length Height Width Weight Connections

Shipping Operating Water, OD Condensate, ID

54.0 in 25.0 in 10.8 in 201 lb 171 lb 0.625 in 0.75 in

Cabinet

Construction Type Cabinet Type

Standard Fiberglass Insulation Flat Top

Piping Hand Cabinet Height Discharge Grille

Left Hand High Sill - 25" Standard 1-piece Steel

Color

Cabinet Subbase Grille

Antique Ivory Oxford Brown Oxford Brown

Fan Controls

Type Motor Drive Type

Type Horsepower Type

Tangential Standard PSC 0.056 HP Direct Microtech III Unit

Controller - Standalone

(1) 37.25 in x 9.75 in x 0.5 in

Options

Heating

Heat Exchanger: Copper

Drain Pan Material

Primary: Plastic

Controls

Thermostat Mounting: Remote - Wall Mounted Thermostat

Thermostat Type: Programmable

Control Transformer: 50VA Control Transformer

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada.

CHP‐1.5 Technical Data Sheet

OM143U Offutt B1226 30 6/21/2024

FA460025R0002

Controls MicroTech III Unit Controller - Standalone operation L ® Communication Module BACnet® Communication Module

Warranty Ext. 4-Yr. Parts (Compressor Only) Ext. 4-Yr. Parts (Refrigerant Circuit)

2-Way Motorized Valve Packages (Option)

Extended End Pocket (Option)

Multi-Directional Grilles (Option) degrees for added control of discharge air direction.

Console Water Source Heat Pump – Flat Top Unit, High Sill, Left Hand Models MHC/MHW – Unit Size 018

Options (Factory Installed)

Physical Data Unit Size 018 Fan Wheel - D x W (In.) 7/16

Fan Motor Horsepower 1/18

Coil Face Area (Sq. Ft.) 2.22 Coil Rows

Refrigerant Charge (Oz.)

Filter, (Qty.) Size (Nominal)

Water Connections (In.)

Condensate Connections (In.)

Weight, Operating (Lbs.) 171

Weight, Shipping (Lbs.) 201

LED Annunciator – LED status lights display fault conditions to the left or right end panel to the control enclosure.

Filter

Hinged Control Box

MicroTech® III Unit Controller – expansion module can be used to control electric heat and multiple fan speeds. A separate L ® or BACnet® communication module can be easily snapped onto the board to accommodate the

MHC-MHW-FT-HS-L-018

Specs

MHC-MHW-FT-HS-L-018 Specs / Page 1 of 2

The Water Source Heat Pump product represented on this document will conform to the drawings and may be made to this document without the prior, express, written authorization of the manufacturer.

Group: WSHP Type:

Date:

CHP‐1.5 MHC‐W_018_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 31 6/21/2024

FA460025R0002

Flat Top Unit, High Sill, Left Hand Piping – Size 018

Unit Size A B C D E F G H J K L M

018 20½ 12½ 7 0.6 1/

N P Q R S T V Y

4 10 1 / 7½ 4

Extended End Pocket (Option) – Dimensions

MHC-MHW-FT-HS-L-018 Specs / Page 2 of 2

CHP‐1.5 MHC‐W_018_HS_F_L_Features‐Dim‐Phys_Data_Drawin

OM143U Offutt B1226 32 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-1.0

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV012

208-

230/60/1 347 3.00 9477 15.1 10.2 9240 3.4 3.1

Unit

Model Number: WGCV012

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 21.5 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

347 CFM 0.70 3.00 gpm / 3.00 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 98.9 75.0 63.0 55.3 53.4 9477 7400 12657 10.2 10.00

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 35.6 70.0 94.5 9240 6282 3.1 11.13

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/1 197 V 5.5 A 6.7 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

4.6 A 27.9 A 0.9 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

19.0 in 24.0 in 19.0 in 133 lb 105 lb 0.50 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant Torque 0.10 hp

HP‐1.0 Technical Data Sheet

OM143U Offutt B1226 33 6/21/2024

FA460025R0002

Unit Options

Controls

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 12 in x 16 in x 1 in

Insulation

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐1.0 Technical Data Sheet

OM143U Offutt B1226 34 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-1.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV012 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐1.0 Smart Source Drawings

OM143U Offutt B1226 35 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-1.5

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV019

208-

230/60/1 600 4.00 15214 16.7 11.2 13940 3.5 3.5

Unit

Model Number: WGCV019

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 29.0 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

600 CFM 0.75 4.00 gpm / 2.53 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 100.4 75.0 63.0 57.2 54.1 15214 11589 19861 11.2 10.24

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 34.8 70.0 91.4 13940 9970 3.5 11.40

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/1 197 V 9.2 A 10.8 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

6.2 A 31.5 A 3.0 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

21.5 in 32.0 in 21.5 in 174 lb 146 lb 0.50 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant CFM 0.17 hp

HP‐1.5 Technical Data Sheet

OM143U Offutt B1226 36 6/21/2024

FA460025R0002

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 16 in x 20 in x 1 in

Insulation

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐1.5 Technical Data Sheet

OM143U Offutt B1226 37 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-1.5 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV019 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐1.5 Smart Source Drawings

OM143U Offutt B1226 38 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-1.5 low

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV019

208-

230/60/1 450 4.00 14456 16.7 10.8 13370 3.5 3.2

Unit

Model Number: WGCV019

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 29.0 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

450 CFM 0.75 4.00 gpm / 2.53 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 100.0 75.0 63.0 54.9 51.5 14456 9800 19027 10.8 10.24

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 35.2 70.0 97.4 13370 9144 3.2 11.40

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/1 197 V 9.2 A 10.8 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

6.2 A 31.5 A 3.0 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

21.5 in 32.0 in 21.5 in 174 lb 146 lb 0.50 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant CFM 0.17 hp

HP‐1.5 low Technical Data Sheet

OM143U Offutt B1226 39 6/21/2024

FA460025R0002

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 16 in x 20 in x 1 in

Insulation

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐1.5 low Technical Data Sheet

OM143U Offutt B1226 40 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-1.5 low www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV019 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐1.5 low Smart Source Drawings

OM143U Offutt B1226 41 6/21/2024

FA460025R0002

www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV024 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐1.5 low Smart Source Drawings

OM143U Offutt B1226 42 6/21/2024

FA460025R0002

www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV048 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐1.5 low Smart Source Drawings

OM143U Offutt B1226 43 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-2.0

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV024

208-

230/60/3 800 5.00 21109 15.9 10.5 18577 3.4 3.6

Unit

Model Number: WGCV024

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 32.0 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

800 CFM 0.75 5.00 gpm / 2.50 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 101.8 75.0 63.0 56.7 53.7 21109 15863 27988 10.5 9.07

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 34.3 70.0 91.4 18577 13457 3.6 10.10

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/3 197 V 10.1 A 11.9 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

7.1 A 55.4 A 3.0 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

21.5 in 39.0 in 21.5 in 197 lb 169 lb 0.75 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant CFM 0.33 hp

HP‐2.0 Technical Data Sheet

OM143U Offutt B1226 44 6/21/2024

FA460025R0002

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 20 in x 20 in x 1 in

Insulation

Compressor: Sound Blanket

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐2.0 Technical Data Sheet

OM143U Offutt B1226 45 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-2.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV024 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐2.0 Smart Source Drawings

OM143U Offutt B1226 46 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-2.0 low

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV024

208-

230/60/3 600 5.00 20176 15.9 10.3 18109 3.4 3.5

Unit

Model Number: WGCV024

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 32.0 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

600 CFM 0.75 5.00 gpm / 2.50 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 101.3 75.0 63.0 54.1 50.9 20176 13613 26887 10.3 9.07

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 34.6 70.0 97.8 18109 12887 3.5 10.10

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/3 197 V 10.1 A 11.9 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

7.1 A 55.4 A 3.0 A 15 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

21.5 in 39.0 in 21.5 in 197 lb 169 lb 0.75 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant CFM 0.33 hp

HP‐2.0 low Technical Data Sheet

OM143U Offutt B1226 47 6/21/2024

FA460025R0002

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 20 in x 20 in x 1 in

Insulation

Compressor: Sound Blanket

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐2.0 low Technical Data Sheet

OM143U Offutt B1226 48 6/21/2024

FA460025R0002

www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV024 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐2.0 low Smart Source Drawings

OM143U Offutt B1226 49 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-3.0

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV036

208-

230/60/3 1200 6.00 32268 15.8 10.4 28558 3.4 3.4

Unit

Model Number: WGCV036

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 48.0 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

1200 CFM 0.75 6.00 gpm / 2.00 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 105.0 75.0 63.0 56.8 53.5 32268 23758 42818 10.4 7.44

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 33.0 70.0 91.9 28558 20067 3.4 8.29

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/3 197 V 15.4 A 18.0 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

10.4 A 73.0 A 5.0 A 25 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

26.0 in 44.0 in 21.5 in 221 lb 193 lb 0.75 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant CFM 0.33 hp

HP‐3.0 Technical Data Sheet

OM143U Offutt B1226 50 6/21/2024

FA460025R0002

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 24 in x 24 in x 1 in

Insulation

Compressor: Sound Blanket

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐3.0 Technical Data Sheet

OM143U Offutt B1226 51 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-3.0 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV036 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐3.0 Smart Source Drawings

OM143U Offutt B1226 52 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-3.5

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV042

208-

230/60/3 1400 7.00 35754 16.7 10.9 30927 3.4 3.4

Unit

Model Number: WGCV042

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range

Vertical R-410A 52.0 oz Ground Loop (Geothermal)

Unit Performance

Air & Fluid Flow

Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude

1400 CFM 0.75 7.00 gpm / 2.00 gpm/ton

Propylene Glycol 30.0 % 0 ft

Cooling Performance

Fluid Temperature Air Temperature Capacity Heat of Rejection

Btu/hr

EER @

design

Fluid Pressure

Drop Entering Leaving Entering Leaving Total

Btu/hr Sensible Btu/hrDry Bulb Wet Bulb Dry Bulb Wet Bulb

90.0 104.1 75.0 63.0 57.5 54.0 35754 26611 46919 10.9 10.96

Heating Performance

Fluid Temperature Air Temperature Capacity Heat of Absorption

Btu/hr

COP @ design Fluid Pressure DropEntering Leaving Entering Leaving Total

Btu/hrDry Bulb Dry Bulb

40.0 33.5 70.0 90.3 30927 21736 3.4 12.20

Electrical

Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA

208-230/60/3 197 V 20.5 A 23.8 A

Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size

13.2 A 88.0 A 7.3 A 35 A

*Short-Circuit Current = 5 kA rms symmetrical, 600 V maximum

Physical

Unit

Depth Height Width Weight Connection

Shipping Operating Water Condensate

26.0 in 44.0 in 21.5 in 233 lb 205 lb 0.75 in 0.75 in

Fan

Motor Type Motor Horsepower

ECM Constant CFM 0.50 hp

HP‐3.5 Technical Data Sheet

OM143U Offutt B1226 53 6/21/2024

FA460025R0002

Unit Control: Microtech III

Control Transformer: Standard 50 VA Transformer

Thermostat / Sensor Control: Thermostat Control

Unit Airflow Configuration

Return Air Location: Right Hand

Discharge Air Location: Top

Construction Options

Drain Pan Material

Primary: Stainless Steel

Filters

Filter Rack Type: Standard 1-inch 2-Sided

Filter Type: 1-inch Throwaway (Quantity) Nominal Filter

Dimensions:

(1) 24 in x 24 in x 1 in

Insulation

Compressor: Sound Blanket

Compressor Compartment: 1/2 inch Fiberglass, Skin-faced

Air Compartment: 1/2 inch Fiberglass, Skin-faced

Miscellaneous

Coil Treatment: None

Warranty

Unit Warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance

AHRI Certification

All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada.

HP‐3.5 Technical Data Sheet

OM143U Offutt B1226 54 6/21/2024

FA460025R0002

Product Drawing Unit Tag: HP-3.5 www.DaikinApplied.com Software Version: 12.30

Product: Project Name: Offutt B1226 Model: WGCV042 Sales Office: Mechanical Sales, Inc.

Sales Engineer: Mike Nebel June 21, 2024 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25 Dwg Units: (in)

No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications.

HP‐3.5 Smart Source Drawings

OM143U Offutt B1226 55 6/21/2024

FA460025R0002

Date 6/21/2024

Submitted By Mike Nebel

Software Version 12.30

Unit Tag HP-4.0

Unit Overview

Model Number

Voltage V/Hz/Phase

Airflow

CFM

Fluid Flow gpm

Cooling Capacity

Btu/hr

Cooling Efficiency

EER@AHRI

Cooling Efficiency EER@Design

Heating Capacity

Btu/hr

Heating Efficiency

COP@AHRI

Heating Efficiency COP@Design

WGCV048

208-

230/60/3 1600 10.00 39739 16.9 12.5 41447 3.6 3.8

Unit

Model Number: WGCV048

Unit Type: SmartSource Compact - Single Stage

Approval: ETL, CETL, AHRI

Confi…