This document appears to be Attachment 07 - Drawings - General - Civil.pdf, which contains civil engineering drawings related to Solicitation Number 36C25024B0031_1 for the construction of private in-patient rooms and primary clinics at the Ann Arbor, MI facility of the Department of Veterans Affairs Technology Acquisition Center Austin.
The solicitation is for the construction project 506-334, with the objective to construct private in-patient rooms and primary clinics. The Department of Veterans Affairs is the federal agency issuing this solicitation. This document does not contain details on the specific products, services, response dates, pricing terms, set asides, or other salient information related to the contract opportunity. It appears to be a technical drawing attachment provided as part of the overall solicitation package.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
X
X
1/A101
X
A101 SIM.
EXP.X
TOILET ACCESSORY TAGX SIGNAGE TAG
A101
SIM
X
FULLER COURT
F U
L L E
R R
O A
D
GLAZIER W
AY
FULLER COURT
B E
A L
A V
E N
U E
FULLER ROAD
B O
N
IS
T E
E L
B L V
D
1W
1E
37 15 31 22 T09
H
J
G B
A
D
VA MEDICAL CIRCLE
PROJECT LOCATION
S
TA
TE
OF MICH
IG
A
L
IC
E
N S
ED ARC
H
IT
E C T
N
MICHAEL
DUKE
1301072431
No.
ARCHITECT
VA Project No.
RDC/JPA Project No.
Department of Veterans Affairs Medical Center
524 FERNWOOD AVENUE
ALTAMONTE SPRINGS, FLORIDA 32701
407.830.6522 P
937.461.0260 F
RDC / JOHN POE ARCHITECTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
HEAPY ENGINEERING
1400 WEST DOROTHY LANE
DAYTON, OH 45409
937.224.0861 P
937.224.5777 F
TTL ASSOCIATES, INC.
1915 NORTH 12 STREET
TOLEDO, OH 43604
419.324.2222 P
419.241.1808 F
ENVIRONMENTAL ENGINEERING
ARCHITECTURE | PLANNING | INTERIOR DESIGN
MECHANICAL | ELECTRICAL | PLUMBING
THP LIMITED, INC.
100 E. EIGHTH STREET, SUITE 300
CINCINNATI, OH 45202
513.241.3222 P
513.241.2981 F
STRUCTURAL ENGINEERING
MIDWESTERN CONSULTING
3815 PLAZA DRIVE
ANN ARBOR, MI 48108
734.995.0200 P
734.995.0599 F
CIVIL ENGINEERING
Project Schedule Date
Schematic Design 15% 02.16.2021
Schematic Design 35% 04.16.2021
Design Development 65% 09.24.2021
Design Development 65% (Re-submittal) 11.15.2021
/1 /2
:0
:0
P M
Construct Private In-Patient Rooms & Primary Clinics
12.15.2023
COVER SHEET
G001
RWTH
506-334
Ann Arbor, Michigan (506)
B01W
Construct Private In-Patient Rooms & Primary Clinics
2215 Fuller Road Ann Arbor, MI 48105 PROJECT #: 506-334
JEFF MEANS
100% BID DOCUMENTS
20014.00
GENERAL CONSTRUCTION NOTES
* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS TO THE
CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).
1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,
INTERNATIONAL BUILDING CODE, AND OTHER CODES AS IDENTIFIED IN VHA
PROGRAM GUIDE PG-18-3, TOPIC 01, CODES, STANDARDS AND EXECUTIVE
ORDERS WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,
TECHNICAL INFORMATION LIBRRARY WEBSITE.
2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND
DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13
WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS
TECHNICAL INFORMATION LIBRARY WEBSITE.
3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT
EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED
WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH
ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT
ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.
5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF
NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO
REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT
SURFACES TO REMAIN.
6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW
MATERIALS.
7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO
BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE
SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT
THROUGH FINISHED OPENINGS.
DRAWING INDEX
GRAPHIC SYMBOLS
N Scale: 1" = 160'-0"
SITE PLAN
8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,
HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS
AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT
DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL
WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.
9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS
SPECIFICALLY NOTED OTHERWISE. IF NO FINISH IS INDICATED AT A
PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(S) AS
INDICATED AT SIMILAR CONDITIONS.
10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL
SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE
THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE
NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR
SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.
11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED
WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF
THE WALL.
12. FIRE PROTECTION CONTRACTOR'S SPRINKLER DESIGN WILL BE SUBJECT TO
AN INDEPENDENT REVIEW BY A CERTIFIED FIRE PROTECTION ENGINEER
RETAINED BY THE OWNER. THE FIRE PROTECTION CONTRACTOR IS
RESPONSIBLE FOR MAKING ANY REQUIRED CHANGES TO THE DESIGN AS
IDENTIFIED BY THE OWNER'S FIRE PROTECTION ENGINEER AS NECESSARY
FOR COMPLIANCE WITH SPECIFIED NFPA REQUIREMENTS.
13. CONTRACTOR SHALL COORDINATE DESIGNATED OUTSIDE LAYDOWN AREA &
ANY ROOMS INSIDE THE FACILITY FOR MATERIAL STORAGE WITH C.O.R.
PRIOR TO COMMENCEMENT OF WORK
GENERAL
G001 COVER SHEET
G100 CODE PLANS
G200 SEQUENCE OF CONSTRUCTION
G301 BID DEDUCT ALTERNATE 01 & 02
G302 BID DEDUCT ALTERNATE 03 & 04
CIVIL
C001 EXISTING CONDITIONS AND SITE PREP
STRUCTURAL
S001 GENERAL STRUCTURAL NOTES
S002 TYPICAL DETAILS
S003 TYPICAL DETAILS
S104 THIRD AND FOURTH FLOORS FRAMING PLANS
S105 FIFTH FLOOR AND ROOF FRAMING PLANS
S106 EXISTING ROOF FRAMING PLAN
S201 FRAMING DETAILS
S301 TRUSS ELEVATION AND DETAILS
S401 STEEL COLUMN SCHEDULE AND DETAILS
S501 WEST ELEVATION SUPPLEMENTAL FRAMING
ARCHITECTURAL
AD102 SECOND FLOOR - DEMOLITION PLAN
AD103 THIRD FLOOR / SECOND FLOOR ROOF - DEMOLITION PLAN
AD104 FOURTH FLOOR - DEMOLITION PLAN
AD105 FIFTH FLOOR - DEMOLITION PLAN
AD106 SIXTH FLOOR - DEMOLITION PLAN
AD122 SECOND FLOOR REFLECTED CEILING - DEMOLITION PLAN
AD201 EXTERIOR DEMOLITION ELEVATIONS
AD202 EXTERIOR DEMOLITION ELEVATIONS & DETAILS
A103-D THIRD FLOOR DIMENSION PLAN
A103-N THIRD FLOOR NOTE PLAN
A104-D FOURTH FLOOR DIMENSION PLAN
A104-N FOURTH FLOOR NOTE PLAN
A105-D FIFTH FLOOR DIMENSION PLAN
A105-N FIFTH FLOOR NOTE PLAN
A106 SIXTH FLOOR / ROOF PLAN
A122 SECOND FLOOR - REFLECTED CEILING PLAN
A123 THIRD FLOOR - REFLECTED CEILING PLAN
A124 FOURTH FLOOR - REFLECTED CEILING PLAN
A125 FIFTH FLOOR - REFLECTED CEILING PLAN
A126 CEILING DETAILS
A201 EXTERIOR ELEVATIONS
A202 EXTERIOR ELEVATIONS
A300 WALL TYPES
A301 BUILDING SECTIONS
A311 WALL SECTIONS
A321 DETAILS
A322 DETAILS
A401 INTERIOR ELEVATIONS
A402 INTERIOR ELEVATIONS
A403 INTERIOR ELEVATIONS
A404 INTERIOR ELEVATIONS
A407 RESTROOM INTERIOR ELEVATIONS
A511 CASEWORK SECTIONS & DETAILS
A601 DOOR SCHEDULE & DETAILS
A611 WINDOW & STOREFRONT
A612 WINDOW DETAILS
IF001 FINISH LEGEND
IF301 THIRD FLOOR - FLOOR FINISH PLAN
IF302 THIRD FLOOR - WALL FINISH PLAN
IF303 THIRD FLOOR - WALL PROTECTION PLAN
IF401 FOURTH FLOOR - FLOOR FINISH PLAN
IF402 FOURTH FLOOR - WALL FINISH PLAN
IF403 FOURTH FLOOR - WALL PROTECTION PLAN
IF501 FIFTH FLOOR - FLOOR FINISH PLAN
IF502 FIFTH FLOOR - WALL FINISH PLAN
IF503 FIFTH FLOOR - WALL PROTECTION PLAN
IS301 THIRD FLOOR - SIGNAGE PLAN
IS401 FOURTH FLOOR - SIGNAGE PLAN
IS501 FIFTH FLOOR - SIGNAGE PLAN
IS600 SIGNAGE DETAILS
QH103 THIRD FLOOR - FURNITURE & EQUIPMENT PLAN
QH104 FOURTH FLOOR - FURNITURE & EQUIPMENT PLAN
QH105 FIFTH FLOOR - FURNITURE & EQUIPMENT PLAN
FIRE SUPPRESSION
F001 ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS
F002 BID DEDUCT ALTERNATE 01 & 02
F003 BID DEDUCT ALTERNATE 03 & 04
FX103 PARTIAL THIRD FLOOR PLAN
FX104 PARTIAL FOURTH FLOOR PLAN
FX105 PARTIAL FIFTH FLOOR PLAN
PLUMBING
P001 ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS
P002 BID DEDUCT ALTERNATE 01 & 02
P003 BID DEDUCT ALTERNATE 03 & 04
PD102 PARTIAL SECOND FLOOR PLAN - REMOVALS
PD103 PARTIAL THIRD FLOOR PLAN - REMOVALS
PD104 PARTIAL FOURTH FLOOR PLAN - REMOVALS
PD105 PARTIAL FIFTH FLOOR PLAN - REMOVALS
PL102 PARTIAL SECOND FLOOR PLAN - DRAINAGE
PL103 PARTIAL THIRD FLOOR PLAN - DRAINAGE
PL104 PARTIAL FOURTH FLOOR PLAN - DRAINAGE
PL105 PARTIAL FIFTH FLOOR PLAN - DRAINAGE
PL106 PARTIAL SIXTH FLOOR PLAN - DRAINAGE
PP103 PARTIAL THIRD FLOOR PLAN - DISTRIBUTION
PP104 PARTIAL FOURTH FLOOR PLAN - DISTRIBUTION
PP105 PARTIAL FIFTH FLOOR PLAN - DISTRIBUTION
PG105 PARTIAL FIFTH FLOOR PLAN - MEDICAL GAS
P401 ENLARGED PLAN
P601 SCHEDULES & DIAGRAMS
P901 SANITARY WASTE AND VENT DIAGRAM
P902 DOMESTIC WATER DIAGRAM
P903 MEDICAL GAS DIAGRAM
P904 STORM & SECONDARY OVERFLOW DIAGRAM
MECHANICAL
M001 ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS
M002 BID DEDUCT ALTERNATES
M003 BID DEDUCT ALTERNATES
MD102 PARTIAL SECOND FLOOR PLAN - REMOVALS
MD103 PARTIAL THIRD FLOOR PLAN - REMOVALS
MD104 PARTIAL FOURTH FLOOR PLAN - REMOVALS
MD105 PARTIAL FIFTH FLOOR PLAN - REMOVALS
MH101 PARTIAL FIRST FLOOR PLAN - TEMPORARY AIR HANDLING UNIT
MH102 PARTIAL SECOND FLOOR PLAN - DUCTWORK
MH103 PARTIAL THIRD FLOOR PLAN - DUCTWORK
MH104 PARTIAL FOURTH FLOOR PLAN - DUCTWORK
MH105 PARTIAL FIFTH FLOOR PLAN - DUCTWORK
MH106 PARTIAL SIXTH FLOOR PLAN - DUCTWORK
MP103 PARTIAL THIRD FLOOR PLAN - PIPING
MP104 PARTIAL FOURTH FLOOR PLAN - PIPING
MP105 PARTIAL FIFTH FLOOR PLAN - PIPING
MP106 PARTIAL SIXTH FLOOR PLAN - PIPING
M401 ENLARGED PLANS
M402 ENLARGED PLAN
M403 ENLARGED PLANS
M501 DETAILS
M502 DETAILS
M503 DETAILS
M504 DETAILS
M505 AIRFLOW SCHEMATICS
M601 SCHEDULES
M602 SCHEDULES
M901 CONTROLS
M902 CONTROLS
M903 CONTROLS
M904 CONTROLS
ELECTRICAL
E001 ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS
E002 BID DEDUCT ALTERNATES
ED103 PARTIAL THIRD FLOOR PLAN - REMOVALS
ED105 PARTIAL FIFTH FLOOR PLAN - REMOVALS
EL103 PARTIAL THIRD FLOOR PLAN - LIGHTING
EL104 PARTIAL FOURTH FLOOR PLAN - LIGHTING
EL105 PARTIAL FIFTH FLOOR PLAN - LIGHTING
EP101 PARTIAL FIRST FLOOR PLAN - POWER
EP103 PARTIAL THIRD FLOOR PLAN - POWER
EP104 PARTIAL FOURTH FLOOR PLAN - POWER
EP105 PARTIAL FIFTH FLOOR PLAN - POWER
EP106 PARTIAL SIXTH FLOOR & ROOF PLAN - POWER
E401 ENLARGED PLANS
E501 SCHEDULES & DETAILS
E502 PANEL SCHEDULES
E503 PANEL SCHEDULES
E601 PARTIAL SINGLE LINE DIAGRAM
E602 PARTIAL SINGLE LINE DIAGRAM
E603 PARTIAL SINGLE LINE DIAGRAM
E604 PARTIAL SINGLE LINE DIAGRAM
TELECOMMUNICATIONS
T001 ABBREVIATION, SYMBOLS & INDEX OF DRAWINGS
T002 BID DEDUCT ALTERNATES 01 & 02
T003 BID DEDUCT ALTERNATES 03 & 04
TD103 PARTIAL THIRD FLOOR PLAN - REMOVALS
TD104 PARTIAL FOURTH FLOOR PLAN - REMOVALS
TD105 PARTIAL FIFTH FLOOR PLAN - REMOVALS
TA103 PARTIAL THIRD FLOOR PLAN - TECHNOLOGY
TA104 PARTIAL FOURTH FLOOR PLAN - TECHNOLOGY
TA105 PARTIAL FIFTH FLOOR PLAN - TECHNOLOGY
TA106 FIRST FLOOR PLAN BUILDING 28 - TECHNOLOGY
TY103 PARTIAL THIRD FLOOR PLAN - TECHNOLOGY SECURITY
TY104 PARTIAL FOURTH FLOOR PLAN - TECHNOLOGY SECURITY
TY105 PARTIAL FIFTH FLOOR PLAN - TECHNOLOGY SECURITY
Revisions Date
0-HR Smoke Partition: NFPA 101 - 8.4
1-HR Smoke Barrier: NFPA 101 - 8.5
2-HR Smoke Barrier: NFPA 101 - 8.5
1-HR Fire Barrier: NFPA 101 - 8.3
2-HR Fire Barrier: NFPA 101 - 8.3
Means of Egress
Egress Capacity
Existing Wall to Remain
New Wall
Area of New Work
No Architectural Work this Area
Suite Designation
Area Open to Corridor
Fire Extinguisher
TOTAL TRAVEL DISTANCE= 180'
(MAXIMUM= 200')
TOTAL TRAVEL DISTANCE= 183
(MAXIMUM= 200')
Common Path of Travel= 90'
(MAXIMUM= 100' )
COMPARTMENT ZONE 3
7,200 SF
COMPARTMENT ZONE 2
14,200 SF
COMPARTMENT ZONE 1
12,194 SF
Common Path of Travel= 75'
(MAXIMUM= 100' )
TOTAL TRAVEL DISTANCE= 172'
(MAXIMUM= 200' )
TOTAL TRAVEL DISTANCE= 142'
(MAXIMUM= 200' )
TOTAL TRAVEL DISTANCE= 95'
(MAXIMUM= 200' )
SUITE
9,117 SF
Common Path of Travel= 42'
(MAXIMUM= 100')
SUITE EXIT= 100'
(MAXIMUM= 100')
TOTAL TRAVEL DISTANCE= 148'
(MAXIMUM= 200')
SUITE EXIT= 98'
(MAXIMUM= 100')
TOTAL TRAVEL DISTANCE= 141'
(MAXIMUM= 200')
COMPARTMENT ZONE 4
7,316 SF
COMPARTMENT ZONE 3
20,260 SF
COMPARTMENT ZONE 2
6,539 SF
S
TA
TE
OF MICH
IG
A
L
IC
E
N S
ED ARC
H
IT
E C T
N
MICHAEL
DUKE
1301072431
No.
ARCHITECT
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
Project Schedule Date
Schematic Design 15% 02.16.2021
Schematic Design 35% 04.16.2021
Design Development 65% 09.24.2021
Construction Documents 95% 10.26.2023
Bid Documents 100% 12.15.2023
Design Development 65% (Re-submittal) 11.15.2021
/1 /2
:4
:5
P M
Construct Private In-Patient Rooms & Primary Clinics
12.15.2023
CODE PLANS
G100
RWTH
506-334
Ann Arbor, Michigan (506)
B01W
JEFF MEANS
100% BID DOCUMENTS
20014.00
CODE LEGEND
N Scale: 1/16" = 1'-0"
THIRD FLOOR - CODE PLAN
N
Scale: 1/16" = 1'-0"
FOURTH FLOOR - CODE PLAN
N Scale: 1/16" = 1'-0"
FIFTH FLOOR - CODE PLAN
Project Data Project Name: AE Construct In-Patient Rooms Project Number: VA# 506-334 / RDCJPA# 20014.00 Project Address: VA Ann Arbor Healthcare System
Building 1W 2215 Fuller Road, Ann Arbor, MI 48105
Project Description: 3 story vertical addition on the west side of Building 1 and associated interior remodeling of spaces adjacent to addition. Addition to accommodate future 6th thru 9th floors.
Applicable Building Codes Authority Having Jurisdiction Ann Arbor – Veterans Affairs Medical Center Building Code: NFPA 101, Life Safety Code, 2021 Edition
NFPA 96, Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, 2021 Edition International Building Code, 2021 Edition
Accessibility Code: VA Barrier Free Design Standard, PG-18-13/ABAAS, January 1, 2017 (revised October 1, 2023)
Structural Code: International Building Code, 2021 Edition Elevator Code: N/A Energy Code: ASHRAE 90.1-2021 (target 30% better than baseline) Mechanical Code: 2021 International Mechanical Code Plumbing Code: 2021 International Plumbing Code
2021 NFPA 54 National Gas Fuel Code Electrical Code: 2020 NFPA 70 National Electrical Code Fire Code: 2019 NFPA 72 National Fire Alarm Code
2019 NFPA 13, 13D & 13R
Life Safety Summary Occupancy: Third Floor: Ambulatory
Fourth Floor: Business Fifth Floor: Healthcare
Construction Type: II (222) (NFPA 5000, Table 7.4.1) Actual Height: 61’-5” Allowable Area: Unlimited (NFPA 5000, Table 7.4.1) Actual Area: Third Floor: Infill: 5,311 SF | Renovation: 2,102 SF
Fourth Floor:Infill: 5,311 SF | Renovation: 1,056 SF Fifth Floor: Infill: 5,311 SF | Renovation: 3,800 SF Total: Infill: 15,933 SF | Renovation: 6,958 SF
Hazard of Content: Ordinary Hazard Contents Sprinkler System: Fully suppressed (NFPA 13) Seismic Design Category: Category A Fire Resistance Ratings: Structural Frame: 2 hour
Exterior Bearing Walls: 2 hour Interior Bearing Walls: 2 hour Exterior Non-Bearing Walls: 0 hour Interior Non-Bearing Walls: 0 hour Columns: 2 hour Floor Construction: 2 hour Roof Construction: 1 hour
Smoke Compartment: Third Floor (Max 40,000 sf) Compartment Zone 1 12,194 s.f.
Compartment Zone 2 13,969 s.f.
Compartment Zone 3 8,170s.f.
Fourth Floor Compartment Compartment Zone 2 33,838 s.f.
Fifth Floor (Max 22,500 sf) Compartment Zone 2 6,539 s.f.
Compartment Zone 3 20,260 s.f.
Compartment Zone 4 7,316 s.f.
Suite: Maximum SF (10,000 sf) 9,021 s.f.
Direct visual supervision provided.
Total coverage automatic smoke detection.
Required Separations: Storage Rooms > 100 sf: 1 HR Fire Barrier (Healthcare Only)
Boiler/Furnace Rooms: 1 HR Fire Barrier Electrical Rooms: 1 HR Fire Barrier Stairs: Existing Shafts: 1 HR Connecting >4 stories
2 HR Connecting <4 stories Corridors: 0HR Smoke Partition
(Heathcare only) Travel Distance Restrictions:
Dead-End Corridor Limit: 30 ft. Health Care 50 ft. Ambulatory 50 ft. Business
Common Path of Travel: 100 ft.
Travel Distance to Suite Exit: 100 ft.
Travel Distance to Exits: 200 ft.
300 ft Business Travel Distance from Room: 50 ft. Health Care
150 ft Ambulatory 300 ft Business
ALL RENOVATION WORK IN THIS
AREA TO BE COMPLETED AFTER
REMAINDER OF FLOOR HAS
BEEN TURNED OVER TO THE VA
LOUNGE
NURSE
STATION
NS-503
STAFF
LOUNGE
OFFICE
SOILED
HOLD
1BR
ISOLATION
ROOM #1
BATH
505A
BATH
507A
1BR
PATIENT
ROOM #2
FEMALE
LAV
522D
MALE LAV
522B
CLEAN
UTILITY
EQUIPMENT
ALCOVE
ANTE
505B
OFFICE
CLEAN
LINEN
LOCKERS
522A
LOCKERS
522C
NURSE
STATION
NS-500
SPACE
WHEEL
CHAIR/
STRETCHER
MED ROOM
1BR
PATIENT
ROOM #3
BATH
509A
1BR
PATIENT
ROOM #4
BATH
515A
BATH
517A
BATH
519A
NURSE
STATION
NS-501
NUTRITION
1 BR
PATIENT
ROOM #7
1 BR
PATIENT
ROOM #8
BATH
524A
1 BR
PATIENT
ROOM #9
BATH
525A
BATH
523A
ALCOVE
1BR
PATIENT
ROOM #5
1BR
PATIENT
ROOM #6
NURSE
STATION
NS-502
CORRIDOR
C5-51
STAFF
LOUNGE
B511
STAFF
LOUNGE
B509
ELECTRICAL
A511
ELECTRICAL
A578
DATA
A575
DATA
A525
CORRIDOR
C5-50
CORRIDOR
C5-52
CORRIDOR
C5-07
CORRIDOR
C5-09
CORRIDOR
C5-13
STAGING AREA
-CRANE LOCATION
-DUMPSTERS
-JOB TRAILER
CONFIRM WITH VA COR LOCATION OF
CONTRACTOR PARKING AND FENCING
SUBCONTRACTOR PARKING OFFSITE
PROJECT LOCATION
6 FT HIGH CHAIN LINK FENCING
S
TA
TE
OF MICH
IG
A
L
IC
E
N S
ED ARC
H
IT
E C T
N
MICHAEL
DUKE
1301072431
No.
ARCHITECT
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
Project Schedule Date
Schematic Design 15% 02.16.2021
Schematic Design 35% 04.16.2021
Design Development 65% 09.24.2021
Construction Documents 95% 10.26.2023
Bid Documents 100% 12.15.2023
Design Development 65% (Re-submittal) 11.15.2021
/1 /2
:4
:5
P M
Construct Private In-Patient Rooms & Primary Clinics
12.15.2023
SEQUENCE OF CONSTRUCTION
G200
RWTH
506-334
Ann Arbor, Michigan (506)
B01W
JEFF MEANS
100% BID DOCUMENTS
20014.00
N.T.S.Scale:
FIFTH FLOOR SEQUENCE OF CONSTRUCTION
N.T.S.Scale:
STAGING PLAN
2/A201
C3-A
307B
OPEN
OFFICE
COMMON
SPACE
STORAGE
307A
HEALTHY
TEACHING
KITCHEN
LOBBY
SPACE
CORRIDOR
C3-A
ELECTRICAL
A311
DATA
A370
STORAGE
A317A
307A
C
B
307C
OMIT ALL WORK RELATED TO
THE OPEN OFFICES AND
CHAPEL, INCLUDING
FINISHES, CEILINGS, AND
COLUMN WRAPS. REFER TO
MEP DRAWINGS FOR
MODIFICATIONS TO LIGHTING,
POWER AND HVAC WORK.
SPACE WILL BE UNFINISHED
STORAGE.
01 - DEDUCT ALTERNATE 01:
A401
A401
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
X
X
1/A101
X
A101 SIM.
EXP.X
TOILET ACCESSORY TAGX SIGNAGE TAG
A101
SIM
X
0-HR Smoke Partition: NFPA 101 - 8.4
1-HR Smoke Barrier: NFPA 101 - 8.5
2-HR Smoke Barrier: NFPA 101 - 8.5
1-HR Fire Barrier: NFPA 101 - 8.3
2-HR Fire Barrier: NFPA 101 - 8.3
MECHANICAL
ROOM
ELECTRICAL
SHOP
S-01-4A
400A
30'-7"
/4
15'-8 3/4"
31'-6" 20'-7 1/2"
6'-0"
6'-0 5/8"
OMIT ALL WORK RELATED TO
THE ELECTRICAL SHOP
INCLUDING FINISHES,
CEILINGS, AND COLUMN
WRAPS. REFER TO MEP
DRAWINGS FOR
MODIFICATIONS TO LIGHTING,
POWER AND HVAC WORK.
SPACE WILL BE UNFINISHED
STORAGE.
02 - DEDUCT ALTERNATE 02:
S
TA
TE
OF MICH
IG
A
L
IC
E
N S
ED ARC
H
IT
E C T
N
MICHAEL
DUKE
1301072431
No.
ARCHITECT
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
Project Schedule Date
Schematic Design 15% 02.16.2021
Schematic Design 35% 04.16.2021
Design Development 65% 09.24.2021
Construction Documents 95% 10.26.2023
Bid Documents 100% 12.15.2023
Design Development 65% (Re-submittal) 11.15.2021
/1 /2
:4
:0
P M
Construct Private In-Patient Rooms & Primary Clinics
12.15.2023
BID DEDUCT ALTERNATE 01 & 02
G301
RWTH
506-334
Ann Arbor, Michigan (506)
B01W
JEFF MEANS
100% BID DOCUMENTS
20014.00
Scale: 1/8" = 1'-0"1
BID DEDUCT 01 - REMOVE THIRD FLOOR OFFICES AND
CHAPEL
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. Install fire retardent blocking at all wall mounted equipment, accessories, casework and wall mounted door stops..
D. Verify all conditions in the field prior to fabrication, erection and construction.
E. Coordinate access for all construction, deliveries, and debris removal with the COR. See General Requirements.
F. Maintain rating at all existing rated construction. Repair all damage to existing rated walls.
G. All new structural steel is to be protected with Type 2 applied fireproofing unless noted otherwise. Provide 2 hour rating for all columns, griders and beams unless noted otherwise.
H. Refer to series A400 sheets for interior elevations and accessory schedule.
I. All wall types to be S1.0 unless noted otherwise.
J. All column enclosures to be S2.3 unless noted otherwise.
K. All column enclosures at existing columns to have size verified in field.
GENERAL NOTES
GRAPHIC SYMBOLS
FIRE WALL LEGEND
Scale: 1/8" = 1'-0"2
BID DEDUCT 02 - REMOVE FOURTH FLOOR
ELECTRICAL SHOP
PLAN NOTES
EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
X
X
1/A101
X
A101 SIM.
EXP.X
TOILET ACCESSORY TAGX SIGNAGE TAG
A101
SIM
X
0-HR Smoke Partition: NFPA 101 - 8.4
1-HR Smoke Barrier: NFPA 101 - 8.5
2-HR Smoke Barrier: NFPA 101 - 8.5
1-HR Fire Barrier: NFPA 101 - 8.3
2-HR Fire Barrier: NFPA 101 - 8.3
C3-A
OMIT ALL WORK RELATED TO THE
TEACHING KITCHEN, INCLUDING
FINISHES, CEILINGS, AND COLUMN
WRAPS. REFER TO MEP DRAWINGS
FOR MODIFICATIONS TO LIGHTING,
POWER AND HVAC WORK. SPACE WILL
BE UNFINISHED STORAGE. EXISTING
OFFICE CONSTRUCTION TO REMAIN.
03 - DEDUCT ALTERNATE 03:
OFFICE
B304
OFFICE
B312A
OFFICE
B303
OFFICE
B302
OFFICE
B300
LOUNGE
NURSE
STATION
NS-503
OFFICE
SOILED
HOLD
1BR
ISOLATION
ROOM #1
BATH
505A
BATH
507A
1BR
PATIENT
ROOM #2
CLEAN
UTILITY
EQUIPMENT
ALCOVE
ANTE
505B
OFFICE
NURSE
STATION
NS-500
SPACE
WHEEL
CHAIR/
STRETCHER
MED ROOM
1BR
PATIENT
ROOM #3
BATH
509A
1BR
PATIENT
ROOM #4
BATH
515A
BATH
517A
BATH
519A
NURSE
STATION
NS-501
NUTRITION
1 BR
PATIENT
ROOM #7
1 BR
PATIENT
ROOM #8
BATH
524A
1 BR
PATIENT
ROOM #9
BATH
525A
BATH
523A
ALCOVE
1BR
PATIENT
ROOM #5
1BR
PATIENT
ROOM #6
NURSE
STATION
NS-502
CORRIDOR
C5-51
ELECTRICAL
A511
ELECTRICAL
A578
DATA
A575
DATA
A525
CORRIDOR
C5-07
CORRIDOR
C5-09
ELEC
B520
DATA
B525A
OMIT WORK TO CONSTRUCT NEW
LOUNGE AND LOCKER ROOMS.
RETAIN EXISTING LOCKERS,
RESTROOMS, H.A.C, SOILED
UTILITY AND OFFICE. EXISTING
OFFICE TO BECOME CLEAN LINEN
ROOM.
522F
04 - DEDUCT ALTERNATE 04:
A
A
A
A402
A402
OFFICE
B512
OFFICE
B510
SOILED
UTILITY
B508A
H.A.C.
B508
LAV
B500C
LAV
B500B
LOCKERS
B500A
CLEAN LINEN
S
TA
TE
OF MICH
IG
A
L
IC
E
N S
ED ARC
H
IT
E C T
N
MICHAEL
DUKE
1301072431
No.
ARCHITECT
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
Project Schedule Date
Schematic Design 15% 02.16.2021
Schematic Design 35% 04.16.2021
Design Development 65% 09.24.2021
Construction Documents 95% 10.26.2023
Bid Documents 100% 12.15.2023
Design Development 65% (Re-submittal) 11.15.2021
/1 /2
:4
:1
P M
Construct Private In-Patient Rooms & Primary Clinics
12.15.2023
BID DEDUCT ALTERNATE 03 & 04
G302
RWTH
506-334
Ann Arbor, Michigan (506)
B01W
JEFF MEANS
100% BID DOCUMENTS
20014.00
A. All dimensions are taken to face of gypsum wallboard or unit masonry.
B. Edge of all door jambs at hinge side not otherwise indicated are to be 6" from the face of intersecting walls. Edge of all door jambs at strike side not otherwise located are to be 18" minimum from the face of intersecting walls.
C. Install fire retardent blocking at all wall mounted equipment, accessories, casework and wall mounted door stops..
D. Verify all conditions in the field prior to fabrication, erection and construction.
E. Coordinate access for all construction, deliveries, and debris removal with the COR. See General Requirements.
F. Maintain rating at all existing rated construction. Repair all damage to existing rated walls.
G. All new structural steel is to be protected with Type 2 applied fireproofing unless noted otherwise. Provide 2 hour rating for all columns, griders and beams unless noted otherwise.
H. Refer to series A400 sheets for interior elevations and accessory schedule.
I. All wall types to be S1.0 unless noted otherwise.
J. All column enclosures to be S2.3 unless noted otherwise.
K. All column enclosures at existing columns to have size verified in field.
GENERAL NOTES
GRAPHIC SYMBOLS
FIRE WALL LEGEND
Scale: 1/8" = 1'-0"1
BID DEDUCT 03 - REMOVE THIRD FLOOR TEACHING
KITCHEN
Scale: 1/8" = 1'-0"2
BID DEDUCT 04 - KEEP EXISTING FIFTH FLOOR
LOCKERS AND RESTROOMS
Construct Private In-Patient Rooms & Primary Clinics
12.14.2023
EXISTING CONDITIONS
AND SITE PREP
C001
ACTSCD
PROGRESS PRINT
NOT FOR CONSTRUCTION
RDC/ JOHN POE ARCHITECTS
Revisions Date
VA Project No.
RDC/JPA Project No.
506-334
Ann Arbor, Michigan (506)
B01W
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
JEFF MEANS
100% CONSTRUCTION
DOCUMENTS
20014.00
Project Schedule Date Schematic Design 35% 04.16.2021 Design Development 65% 09.24.2021
11.15.2021Design Development 65% (Re-submittal) 10.26.2023Construction Documents 95% 12.14.2023Construction Documents 100%