Attachment 06-Ltd Asb Survey Report 3-18-25.pdf
PDF 7 MB Posted
- Attached to
- B611 HVAC Repair
- Solicitation number
- FA480326B0001
About this file
This is a Limited Asbestos Survey Report prepared by Emerald, Inc. for the 20th Civil Engineering Squadron at Shaw Air Force Base, South Carolina. The survey was conducted on March 11, 2025, to identify the presence of asbestos-containing materials (ACM) in HVAC equipment and acoustic ceiling tiles of Building 611 prior to HVAC renovation activities. The inspection was authorized by Mr. Matt Wenger, P.E., and conducted by J. Dalton Reames, Jr., a South Carolina Licensed Building Inspector. Twelve bulk samples were collected and analyzed by EMSL Analytical, Inc. using Polarized Light Microscopy (PLM) per EPA Bulk Analysis Method 600/R-93/116, with three samples receiving additional confirmation testing via Transmission Electron Microscopy (TEM) per South Carolina Asbestos Regulations 61-86.1.
The survey results indicate that no friable or non-friable asbestos-containing materials were detected in any of the tested samples as of March 11, 2025. Samples analyzed included gray-colored duct mastic, light tan-colored pipe wrap mastic, light tan-colored HVAC duct wrap mastic, and 2'x2' acoustic ceiling tiles from various locations throughout Building 611, all of which tested negative for asbestos. The report includes laboratory analytical results, chain of custody documentation, site plans identifying sample locations, building inspector licenses for the qualified personnel, and site photographs documenting the HVAC materials and ceiling tile systems inspected. The survey permits the 20th Civil Engineering Squadron to proceed with HVAC renovation activities with the assurance that no asbestos abatement is required for the tested materials.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX A
SITE PLAN
APPENDIX B
ASBESTOS SAMPLE LOG
H M L H M L H M L
611-H-1
611-H-2
611-H-3
611-H-4
611-H-5
611-H-6
611-H-7
611-H-8
611-H-9
611-H-10
611-H-11
611-H-12
X XG M F 6,800 SF X
Storage Room 19
SLC Room 16
Room 8
Dropped Ceiling System
2'x2' Acoustic Ceiling Tiles
NF 200 LF X X X
Room 8 Insulation Wrap on
Pipe Runs
Light Tan-colored HVAC Duct Wrap Mastic
G MRm. 8 Area Restroom
WS Super Rm. 9
Break Room 17
Storage Room 18
Storage Room 19 Insulation Wrap on
Pipe Runs
XXX100 LFNFMG
Light Tan-colored Pipe Wrap Mastic
MG
Gray-colored Seam Mastic of
Metal Duct Towers Duct
Towers Hangar XXX140 LFNF
F/NF
APPROX.
SF/LF
POTENTIAL FOR FUTURE DISTURBANCE
AREA ROOM EXACT
CONTACT VIBRATION AIR EROSION
ADDRESS: Building 611, Shaw Air Force Base, S.C. INSPECTOR: Dalton Reames
SAMPLE #
LOCATION
DESCRIPTION CONDITION TYPE
EMERALD, INC.
ASBESTOS SAMPLE LOG
PROJECT NAME: Shaw AFB: Bldg. 611 - HVAC DATE: 3/11/2025
Condition Type F/NF Potential for Future Disturbance G= Good S= Surface F= Friable H= High D= Damaged TSI= Thermal Systems Insulation NF= Non Friable M= Moderate SD= Significantly Damaged M= Miscellaneous L= Low
APPENDIX C
CHAIN OF CUSTODY
ANALYTICAL RESULTS
APPENDIX D
BUILDING INSPECTOR LICENSES
APPENDIX E
SITE PHOTOGRAPHS
HVAC and Ceiling Tile Materials: Building 611, Shaw Air Force Base, S.C.
Photo #1 No Asbestos Detected in Gray-colored Seam
Mastic Associated with Metal Duct Towers
Photo #2 No Asbestos Detected in Light Tan-colored Pipe
Wrap Mastic Material (Elbows are Plastic)
Photo #3 No Asbestos Detected in Light Tan-colored Mastic or Seam Tape of HVAC Ductwork
Photo #4 No Asbestos Detected in 2’x2’ Acoustic
Ceiling Tiles
| 611 Sample Log.pdf |
| Sheet1 |